The Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Drum is seeking to procure a specific high-efficiency boiler system with precise technical specifications. The solicitation is for a KN Brand condensing high-efficiency cast iron boiler with a maximum capacity of 1,000,000 BTU/HR, designed to operate on natural gas. Key technical requirements include a standard assembly configuration, operational elevation range of 0-6000 feet, and specific voltage parameters of 115/1/60 standard. The boiler must feature a BacNet IP software module, flame safeguard display, and meet specific design codes including National Design Code A and standard state design codes. While detailed evaluation criteria are not explicitly stated, the comprehensive technical specifications suggest a highly technical review process will be employed.

The solicitation is designated as a Total Small Business set-aside, indicating exclusive competition among small business entities within the Power Boiler and Heat Exchanger Manufacturing (NAICS 332410) category. The contract will be managed through the Industrial Boilers product service category (PSC 4410), with proposals due by December 16, 2024. The boiler system includes specific operational features such as a SIKA flow sensor, 50 PSI relief valve, and 115/1/60 pump voltage, with additional technical nuances like low gas pressure switch and standard modulation capabilities. Although precise award value is not disclosed, the detailed specifications suggest a sophisticated procurement process targeting specialized industrial boiler equipment for military installation use. The place of performance will be at the Fort Drum military installation, with the procurement aimed at replacing or upgrading existing boiler infrastructure.

Notice text

Item: BOILER Brand Name: KN Part Number: 10 Salient Characteristics: CONDENSING HIGH EFFICIENCY CAST IRON KN-10BOILERS, Capacity Max: 1,000,000 BTU/HR, Fuel Type: Natural Gas, Assembly Options: Standard, Elevation min/max: 0-6000FT, Supply Voltage min/max: 115/1/60 standard 6-10 110/115/120 same, National Design Code: A (standard), State Design Code: standard, Flow sensor E: SIKA, Relief Valve min/max: 50PSI, Developmental Level: Standard, Pump Voltage: 115/1/60, Pump Overload: .075HP, Flame Safeguard Display: Yes, Software Module: BacNet IP, Freeze Protection: No, Isolation Valve Wiring: No, High Gas Pressure Switch: No, Low gas Pressure Switch: Yes, Flue Outlet Damper Wiring: None, Modulation: Standard

Similar open opportunities

Opportunity Agency Set-aside Responses due
16292 Steam Boiler Replacement Hill AFB, Utah 84056, United States · NAICS 238220 Air Force Sustainment Center Total Small Business
4 TON HVAC UNIT - Bard 1 C Tree Rd McAlester Ok Mcaap 74501 · NAICS 335999 MICC Fort Drum Total Small Business
Boiler Plant Parts - Reno VAMC Reno, Nevada, United States · NAICS 332410 Veterans Integrated Service Network 21 Total Small Business
Building Filters Wdtc Rcvg Dugway Proving Ground POC: Nathan Otasua 4223 2nd St. Dugway, UT 84022 84022 · NAICS 333998 MICC Fort Drum Total Small Business
USCG Station Eaton's Neck Boiler Combustion Analysis and calibration Northport, New York 11768, United States · NAICS 238220 — Total Small Business