Backflow Preventers

Closed Pre-Solicitation Posted

Solicitation number
M00681BackflowPreventers
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
332911 Industrial Valve Manufacturing
Place of performance
Yuma, Arizona 85365, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The United States Marine Corps Regional Contracting Office MCI-West is conducting market research to identify contractors for a one-time supply of backflow preventers to support Marine Corps Air Station Yuma, with responses due by September 9, 2026. This procurement is set aside for total small business.

Place of performance is Marine Corps Air Station Yuma, Arizona. The backflow prevention assemblies must comply with Arizona Department of Environmental Quality cross-connection-control and backflow-prevention requirements under Arizona Administrative Code R18-4-215. Assemblies must meet one of three protection levels based on hazard type: Reduced Pressure Principle (RP) assemblies for health hazards, Pressure Vacuum Breaker (PVB) assemblies for irrigation systems without chemical injection, and Double Check Valve (DC) assemblies where hazard levels permit. All components must be corrosion-resistant and suitable for outdoor installation and potable-water service, with materials meeting safe-drinking-water requirements. The specification includes 19 assembly configurations ranging from one-half inch to 6 inches in diameter, with approved manufacturers including Zurn-Wilkins, Apollo, FEBCO, and Watts.

Interested contractors must submit a brief capabilities statement by the due date, including DUNS number, CAGE code, socio-economic status certification (8(a), HUBZone, SDVOSB, or other), and confirmation of ability to meet all Minimum Salient Characteristics certifications. Respondents should provide total pricing for all items and quantities, including unit prices. This is a Request for Information; responses do not constitute offers and will not be notified of government assessments. NAICS code 332911 applies with a size standard of 750 employees.

Notice text

The Regional Contracting Office MCI-West is conducting market research to identify contractors for providing Backflow Preventors to support Installation Marine Corps Air Station, Yuma, for a one-time buy of supplies. Please provide your total pricing for all items and quantities, to include unit prices, for budget estimates. 

The North American Industry Classification Standard (NAICS) code for this project is 332911 (Industrial Valve Manufacturing with a size standard of 750 Employees, NAICS code compliance verification will occur if/when proposals are submitted).

Minimum Salient Characteristics: See attached draft Minimum Salient Characteristics and respective specification PDFs.

Responses to Request for Information:

Contractors are reminded that this is a REQUEST FOR INFORMATION and is NOT a request for proposal/bid/quote.

Responses to this notice shall not constitute responses to solicitation. Responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. This Request for Information is not to be construed as a commitment by the Government, nor will the Government pay for the information submitted in response. Respondents will not be notified of the results of any government assessments.

It is requested that interested businesses submit to the contracting office a brief capabilities statement. The capabilities statement must clearly detail the firm's ability to perform all aspects of this notice and must include the following:

a) Data Universal Numbering System (DUNS) number, Commercial and Government Entity (CAGE) code, and a statement regarding the socio-economic status of the company (Section 8(a) of the Small Business Act (8a) small business concern, certified Historically Underutilized Business Zone (HUBZone), Service-Disabled Veteran-Owned Small Business (SDVOSB) concern, etc.).

b) Confirmation that your company can meet the certifications required in the Minimum Salient Characteristics, Proposed Units and Terms, and specification worksheet PDFs.

c) Relevant Experience providing supplies identified in the DRAFT Minimum Salient Characteristics to include: experience in performing efforts of similar size and scope within the last three years. Please include a brief description of the project, contract number, and contract value.

Proposals are not to be submitted at this time. This is a Request for Information only, NOT A REQUEST FOR PROPOSAL/BID/QUOTE.

No questions will be answered. The information received will be utilized to assist in formulating the acquisition.

Respondents will not be notified of the results of any government assessments. All responses will be treated as proprietary.

THE DEADLINE FOR RECEIPT OF SUBMISSIONS IS 9 September 2026, 16:30PM (PDT).

All submissions must be sent via electronic mail to: sabastian.dorsett@usmc.mil and allen.l.hayes@usmc.mil.

Primary Point of Contact: Sgt Lake, Contract Specialist

Regional Contracting Office MCI-WEST, Camp Pendleton, CA

Email: sabastian.dorsett@usmc.mil

Proposed Units and Terms:

SIZE              TYPE                                        SPECS                                                                        QUANITY             DIMENSIONS FACT SHEET

1/2"                375XLRP WILKINS                  Size 20mm; Dimensions 8-7/8" 225mm                      2                           A

3/4"                375XLRP WILKINS                  Size 20mm; Dimensions 8-7/8" 225mm                      4                           A

1"                   375XLRP WILKINS                  Size 25mm; Dimensions 11-3/16" 284mm                  4                           A

1"                   RPLF4A APOLLO                    Size 1"; 14-5/8                                                             2                           B

1"                   975XLRP WILKINS                  Size 25mm; Dimensions 13" 330mm                          2                           C

1-1/2"             375XLRP WILKINS                  Size 40mm; Dimensions 15-1/4", 387mm                   2                           A

1-1/2"             975XLRP WILKINS                  Size 40mm; Dimensions 17-3/8", 441mm                  2                            C

2"                   375XLRP WILKINS                  Size 50mm; Dimensions 16", 406mm                         9                            A

2"                   825YRP FEBCO                      Size 17-3/4"                                                                 2                            D

2"                   765PVB FEBCO                      Size 50mm                                                                   5                            E

2"                   975XLRP WILKINS                 Size 50mm; Dimensions 18-1/2" 470mm                     1                            C

2-1/2"             009RP WATTS                        Size 65mm; Dimensions 41-1/4" 1048mm                   2                            Series 009RP WATTS PDF

3"                   009RP WATTS                        Size 34 1/4" 870mm;Dimension 18.5" 470mm             5                            Series 009RP WATTS PDF

4"                   909RP WATTS                        Size 100mm;Dimensions 551/8" 1400mm                   3                             F

4"                   957RP WATTS                        Size 857mm 33 3/4";Dimension 30 1/8" 765 mm         5                            Series 957RP WATTS PDF

4"                   375ARP WILKINS OSY Gate  Size 100mm; Dimensions 37-5/8" 956mm                   5                            G

4"                   709DC WATTS                        Dimensions. 52-3/8" 1332mm                                      2                             I

6"                   375XLRP WILKINS OSY Gate Size 150 Dimensions 44-3/4" 1137mm                       2                             J

Attached are the Excel and Adobe documents providing further information on this requirement. The items can be any brand that meets the minimum specifications provided.

Questions to be considered regarding this requirement:

Approved Equals: Will the Government consider equivalent backflow prevention devices from other nationally recognized manufacturers when the specified manufacturer or model is unavailable, provided the proposed device meets or exceeds the required specifications and applicable certifications?
Answer: Yes.

Partial Deliveries: Will the Government permit partial or staggered deliveries when some devices are immediately available while others have longer manufacturer lead times?
Answer: Yes.

Multiple Manufacturers: Can a vendor provide devices from multiple approved manufacturers to satisfy the requirement, or must all devices be supplied by the same manufacturer?
Answer: Yes.

Substitutions Due to Availability: If a listed model is discontinued, backordered, or unavailable within the required delivery period, what documentation will be required for the Government to approve an equivalent substitute?
Answer: A list of the specifications on the equivalent substitute before moving forward.

Delivery Location and Freight: Will the formal solicitation identify the exact delivery location, unloading requirements, delivery hours, and whether a loading dock or forklift will be available for larger assemblies?
Answer: Yes.

Required Certifications: Are there specific certifications or approvals required for each device, such as ASSE, USC-FCCCHR, NSF/ANSI, AWWA, or other applicable standards, beyond the manufacturer specifications provided?
Answer: No.

The Required Delivery Date is 60 days post award, or sooner.

Please let me know if there are any questions regarding this market research.

Please be aware this is not a request for quotes or proposals and is SOLELY for market research purposes. 

Files

File Type Posted
A1-Minimum Salient Characteristics.pdf PDF
A1-Series 957RP Watts.pdf PDF
A1-Backflow Spec sheets.pdf PDF
A1-Series 009RP Watts.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Valve, flow control NAICS 332919 Naval Supply Systems Command No set-aside
Valve, flow control NAICS 332919 Naval Supply Systems Command No set-aside
Regulator, flow CON NAICS 333998 Naval Supply Systems Command No set-aside
Valve, self-closing Naval Supply Systems Command Total Small Business
Valve, hull/backup NAICS 332919 Naval Supply Systems Command No set-aside