B1130 HVAC Study

Closed Pre-Solicitation Posted

This opportunity was awarded. See its 2 award notices in the notice history.

Solicitation number
FA480325R0003
Agency
Responses due
Set-aside
Woman-Owned Small Business

Opportunity facts

NAICS code
541330 Engineering Services
Place of performance
Shaw AFB, South Carolina 29152, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Air Combat Command is seeking a comprehensive HVAC study for Building B1130 annex at Shaw Air Force Base in South Carolina. The primary objective is to assess and calculate cooling and airflow requirements for both the first and second floors, taking into account building construction, occupancy, and equipment specifications. Contractors will be required to perform detailed technical evaluations, including measuring static pressure, air discharge temperatures, and hydronic flow, with the ultimate goal of restoring proper system settings and identifying system deficiencies. The pre-solicitation notice indicates that interested firms must submit capability statements demonstrating their qualifications in engineering services, specifically under NAICS code 541330. Interested parties must submit their documentation by December 17, 2024, at 12:00 PM EST, with all submissions directed to the specified contracting officers.

The contract opportunity is exclusively set aside for Women-Owned Small Businesses, providing a targeted procurement avenue for qualifying firms. While specific award values were not explicitly detailed in the documentation, the technical complexity of the HVAC assessment suggests a specialized engineering services contract. Contractors will need to provide a comprehensive report documenting all measurements, findings, system adjustments, and potential deficiencies discovered during the investigation. The scope of work includes technical testing of control system components and making precise adjustments based on detailed heat load data analysis. Successful contractors must possess the technical expertise to conduct a thorough systems evaluation and provide actionable recommendations for optimizing the building's HVAC performance, with target system settings of 75 degrees for cooling and 69 degrees for heating.

Notice text

The contractor shall assess/calculate/determine the cooling and airflow requirement for each room based on the building construction, people, and equipment inside on the first and second floors of B1130 annex.

Files

File Type Posted
Sources Sought ONLY.pdf PDF

Notice history

Notice Type Posted
B1130 HVAC Study Commissioning Latest Award Notice
B1130 HVAC Study Award Notice
B1130 HVAC Study Commissioning Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
FY27 HVAC Maintenance Service Fort Myer, Virginia 22211, United States · NAICS 238220 MICC Fort Sam Houston Total Small Business
L7WC02_ B670 Paint Booth and HVAC Warner Robins, Georgia 31098, United States · NAICS 238220 Air Force Sustainment Center No set-aside
HVAC Replacement - MI NAICS 238220 — Total Small Business
FA8501-27-RAPID-990029 RPR RPL HVAC SYSTEM BLDG 300 Bay A/Headhouse Warner Robins, Georgia 31098, United States · NAICS 238220 Air Force Sustainment Center No set-aside
ANF Duchesne Bunkhouse AC Replacement Utah 84078, United States · NAICS 238220 Forest Service Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors