Amendment to Solicitation for High Finesse Dual Wavelength Reference Cavity
Closed Special Notice Posted
- Solicitation number
- 1333ND25QNB680097
- Agency
-
Department of Commerce
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- Gaithersburg, Maryland 20899, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Commerce has issued a Special Notice for an Amendment to Solicitation for a High Finesse Dual Wavelength Reference Cavity, posted on May 20, 2025. The amendment addresses technical clarifications for a specialized optical cavity system intended for the National Institute of Standards and Technology (NIST) Physical Measurement Laboratory. Specifically, the notice provides detailed responses to contractor questions regarding input signal specifications, fiber input requirements, and photodetector performance parameters. The amendment clarifies that the system requires a fiber input to a collimator assembly module, with contractors responsible for mode matching light into optical cavities and generating specific locking signals. The notice also specifies technical details about photodetector bandwidth and noise requirements.
The primary objective of this solicitation is to procure a sophisticated reference cavity system for spectroscopic research, targeting precise measurements with cesium and ytterbium atomic gases at specific wavelengths. Contractors must submit electronic quotations by May 27, 2025, with evaluation criteria prioritizing technical capability, followed by past performance and pricing. Eligibility requires vendors to be registered in the System for Award Management (SAM) and capable of delivering a new system meeting stringent technical specifications, including high-finesse optical cavities with >100,000 finesse at 555.8 nm and 894.6 nm wavelengths. The procurement is structured as a full and open competition using simplified acquisition procedures, with the intent to award a single firm-fixed-price purchase order. Successful contractors must provide a complete system with pre-aligned components, integrated photodetectors, and meet specific performance parameters such as minimal frequency drift and a comprehensive one-year warranty.
Notice text
AMENDMENT TO SOLICITATION HIGH FINESSE DUAL WAVELENGTH REFERENCE CAVITY
CLARIFICATION/QUESTIONS AND RESPONSES AND EXTENSION OF RESPONSE TIME
Questions:
Request for more details about the product requirements:
- The input signal (light): free-space input or fiber input?
- If free-space input, then the light beam size, collimated or divergent one?
- For the Photodetectors, any requirements on the speed of the response (bandwidth)? Noise requirement, ….
Response:
A fiber input to the collimator assembly modules is specified in A.12 of the requirements document. Since the modules must be pre-aligned, the fiber input that is used for alignment should remain attached to the system and be included with it. The contractor is responsible for mode matching the light from the fiber into the optical cavity (or cavities) using a set of lenses and configuring additional optics specified in A.12 and A.13 to generate Pound-Drever-Hall locking signals.
The photodetectors must have a bandwidth sufficient for Pound-Drever-Hall locking to the optical reference cavity, at least 10 MHz. The input current noise for the photodetectors should be < 7 pA/Sqrt(Hz) (which is approximately less than 14 pW/Sqrt(Hz) of noise equivalent power).
Files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation.docx | DOCX document | |
| Statement of Work.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Special Notice | |
| High Finesse Dual Wavelength Reference Cavity System | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Sources Sought Notice for Mid-IR Optical Frequency Comb | National Institute of Standards and Technology | No set-aside | |
| Sources Sought Notice for Continuous Wave Parametric Oscillator (CW OPO) Laser System | National Institute of Standards and Technology | No set-aside | |
| Intent to Sole Source: AFIT - High Finesse WS8-2 Wavemeter | AFLCMC Wright Patterson AFB | No set-aside | |
| High-Precision Wavemeter | AFLCMC Wright Patterson AFB | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity