Access Control Facility (ACF) Visitor Center 1 (VC1)
Closed Solicitation Posted
- Solicitation number
- W912DR20R0011
- Agency
- ENDIST Baltimore US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Fort George G Meade MD 20755 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks a design-build contractor to construct a new 10,000 square foot Access Control Facility at Fort Meade, Maryland. The soliciting agency is the U.S. Army Corps of Engineers, Engineering District Baltimore. The contractor will be responsible for all aspects of design and construction, including site work, utilities, security systems, and demolition of an existing facility. The new facility must meet DoD antiterrorism standards and ADA accessibility requirements. Design and construction must achieve LEED Silver certification and comply with federal energy legislation. Proposals will be evaluated based on offerors' experience, technical approach, and price. The deadline for proposals is September 3, 2020.
There is no set-aside designation for this procurement. The project involves construction of a general building under NAICS 236220 and PSC C – Construction of structures and facilities. The place of performance is Fort Meade in Maryland. The contractor must complete design and construction within 24 months of award.
Notice text
This a a two phase design build construction requirement. Please see solicitation attached.
This project includes the construction of a 10,000 gross square foot new Access Control Facility with the capacity to support the processing of visitors per criteria established by the Unified Facilities Criteria (UFC). These requirements include a waiting area, service counter, break room, offices, restrooms, electrical, mechanical and fire alarm/suppression.
The supporting facilities include site preparation, infrastructure improvements, utility services, perimeter security measures, infrastructure for the telecommunication and the physical security system. The site preparation will include standard clearing, grubbing, cut, fill, grading and environmental (sustainable) features. A surface parking lot and the demolition of the existing ACF will also be a part of this project. The new facility will be required to meet the minimum DoD Antiterrorism standards and to meet the requirements of the American Disabilities ACT (ADA). There may be minimal asbestos, lead paint and bio-hazards remediation in the existing ACF building.
The facility is required to be in compliance with the UFC 1-200-02 High Performance and Sustainable Building Requirements, with Change 4 as dated 01 October 2019. This policy includes the Leadership in Energy and Environmental Design (LEED) Silver which requires certification via third party and requires compliance with the Energy Policy Act of 2005 and the Energy Independence and Security Act of 2007. Low Impact Development will be included in the design and construction of this project as appropriate.
Attachments
| File | Type | Posted |
|---|---|---|
| W912DR20R0011 AMENDMENT 0001_18AUG2020.pdf | ||
| ACF-VC1 - W912DR20R0011_SOLICITATION_31JUL2020.pdf | ||
| Solicitation W912DR20R0011_31Jul2020.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Access Control Facility (ACF) Visitor Center 1 (VC1) | Solicitation | |
| Access Control Facility | Pre-Solicitation | |
| Access Control Facility | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity