AB11-- 1QPCR - real time PCR system
Closed Pre-Solicitation Posted
- Solicitation number
- 36C24421Q0706
- Agency
-
Veterans Integrated Service Network 4
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Place of performance
- Vamc Philadelphia Philadelphia 19104, United States
Notice details come from SAM.gov. Updated .
Notice text
Sources Sought only. This announcement constitutes a Sources Sought Synopsis (market survey). This is not a Request for Quote (RFQ) or a Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. In accordance with FAR 15.201(e), responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract.
The purpose of this sources sought is to determine interest and capability of potential qualified/verified Small businesses relative to the North American Industry Classification code (NAICS) 334516, Analytical Laboratory Instrument Manufacturing. The Small Business Size Standard for this NAICS code is 1000 employees. To make an appropriate acquisition decision for this requirement, the Government will use responses to this sources sought synopsis. The type of solicitation issued and the manner of advertisement will depend on the responses to this sources sought synopsis.
The Department of Veterans Affairs, Philadelphia VA Medical Center has a requirement for one (1) Applied Biosystems QuantStudio 6 Pro Real-Time PCR System (A43166), four (4) AB Assurance, 1PM, QSTUDIO 6 Pro and one (1) QSPRO Block Upgrade 384W (A45954). This will be a Brand Name requirement. Equipment and requirements are:
Applied Biosystems QuantStudio 6 Pro Real-Time PCR System, 96-well, 0.2 mL, Laptop, Description: QuantStudio 6 Pro, Includes: QuantStudio 6 Pro Real-Time PCR System, 96-well, 0.2 mL block, Laptop
Vendor Catalog # A43166
Applied Biosystems Region of Interest (ROI) and Background Plates, 96-well,
Quantity: 2 96-well plate(s), For Use With: ViiA 7 System, Calibration Type: Spectral Calibration, Content And Storage: Store plates at -15 to -25 deg.C, Shipping Condition: Dry Ice
Vendor Catalog # 4432364
Applied Biosystems TaqMan RNase P Instrument Verification Plate for ViiA 7 System, 96-well (for 0.2 mL block), For Use With: ViiA 7 System, Quantity: 1 96-well plate(s), Calibration Type: RNase P Calibration, Instrument Verification Plate
Vendor Catalog # 4432382
Vendor Justification Life Technologies is the sole manufacturer and vendor of the QuantStudioTM 6 Flex Real-Time PCR System (Part Numbers 4485694, 4485691, 4485692, 4485689, 4485697, 4485699).
Applied Biosystems QuantStudio 3/5 10-Dye Spectral Calibration Kit, 96-well, 0.2 mL
Vendor Catalog # A26343
Applied Biosystems MicroAmp Optical Adhesive Film, No. per Case: 25 Covers, Content And Storage: Includes 25 Optical Adhesive Covers. Store at room temperature.
Applied Biosystems MicroAmp EnduraPlate Optical 96-Well Clear Reaction Plates with Barcode, Quantity: 20 Plates, Optical, Clear, Barcode: Includes Barcode, Content And Storage: Store at room temperature., Format: 96-well plate
Applied Biosystems High-Power USB Wi-Fi Module, For Use With: QuantStudio 3, QuantStudio 5, SimpliAmp Thermal Cycler, ProFlex PCR System, Shipping Condition: Room Temperature
Vendor Catalog # A26774
Thermo Scientific QuantStudio Pro Block Upgrade Kit, 96-well, 0.1 mL, For Use With: QuantStudio, Other Accessories, Content And Storage: Includes 96-well, 0.1 mL block, heated cover and accessories, Product Line: QuantStudio
Vendor Catalog # A45955
Applied Biosystems TaqMan RNase P Instrument Verification Plate, Fast 96-well (for 0.1 mL block), Description: 96-well, For Use With: 7500
Fast System, 7900HT Fast System, QuantStudio 12k Flex, QuantStudio 6 Flex, QuantStudio 7, StepOnePlus, Fast Mode, ViiA 7 System, Quantity: 1 Plate
Applied Biosystems Region of Interest (ROI) and Background Plates, Fast 96-well, Quantity: 1 96-well plate(s), For Use With: ViiA 7 System, Calibration Type: Spectral Calibration, Content And Storage: Store plates at -15 to -25 deg.C, Shipping Condition: Dry Ice
Vendor Catalog # 4432426
QS3/5 10 Dye Cal Kit
Vendor Catalog # A26342
QuantStudio Pro Block Upgrade Kit, 384-well, For Use With: QuantStudio, Content And Storage: Includes 384-well block, heated cover, and accessories, Product Line: QuantStudio, Shipping Condition: Room Temperature
Vendor Catalog # A45954
Applied Biosystems TaqMan RNase P Instrument Verification Plate for ViiA 7 System, 384-well, For Use With: ViiA 7 System, Calibration Type: RNase P Calibration, Instrument Verification Plate, Content And Storage: Store plates at -15 to -25 deg.C., Format: 384-well plate, Label or Dye: FAM
Vendor Catalog # 4455280
834-Well 10 Dye Cal Kit
Vendor Catalog # A26341
Applied Biosystems Region of Interest (ROI) and Background Plates, 384-well, For Use With: ViiA 7 System, Calibration Type: Region-of-Interest (ROI) Calibration, Content And Storage: Store plates at -15 to -25 deg.C., Format: 384-well plate, Label or Dye: FAM, LIZ, NED, ROX, VIC, Product Line: ViiA
Vendor Catalog # 4432320
4 year service contract
Full day orientation/training for research staff
Submission Requirements for responses to this Sources Sought Notice:
(1) Your intent to submit a quote for this solicitation when it is formally advertised.
(2) Name of firm with address, phone and point of contact.
(3) Statement of Capability (SOC) stating your capabilities to meet this requirement. Please include if you are offering the items under an existing contract.
(4) A copy of SAM.GOV active registration. Must reflect Data Universal Numbering System (DUNS) commercial and Government Entity (CAGE) and Small Business Administration Certification of Small Business Type, (Reps/Certs)
(5) A statement addressing your socioeconomic status such as Service-Disabled Veteran-Owned, Veteran-Owned, Woman-Owned, Hubzone, etc.
Responses to this Sources Sought Notice must be received by 11:00am EST, May 20, 2021 and sent by email to Ed Ferkel Contract Specialist, Edward.ferkel@va.gov.
Files
| File | Type | Posted |
|---|---|---|
| 36C24421Q0706.docx | DOCX document |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity