About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command (MICC) Fort Drum is seeking to procure one 7.5-ton roof-top air conditioning unit with specific technical specifications including 460V, 3-phase, 60Hz power requirements, factory assembly with R-410A refrigerant, self-contained pressure controls, and direct-drive scroll-type compressors. The solicitation was posted on March 2, 2026, with a proposal due date of March 25, 2026. Key requirements include delivery of the fully assembled and charged unit to the final site in Puerto Rico, including crane service for unloading, as well as a system start-up component that was added through amendment. The procurement falls under NAICS code 333415 (Air-Conditioning and Warm Air Heating Equipment Manufacturing) and PSC code 4120 (Air Conditioning Equipment). While specific evaluation criteria are not detailed in this notice, the government's emphasis on factory assembly, proper refrigerant charging, and inclusion of installation services suggests that technical compliance and delivery capability will be primary evaluation factors.

This opportunity is designated as a Total Small Business set-aside, limiting competition to small business entities as defined by the Small Business Administration. No incumbent contractor or current contractor information is provided in the solicitation notice. The place of performance is Building 37 at South Gate Road, Fort Buchanan in Guaynabo, Puerto Rico 00934. Although no explicit budget range is disclosed in this notice, the scope involves a single unit procurement with associated delivery and installation services, suggesting a relatively modest contract value. The solicitation does not specify a performance timeline beyond the delivery requirement to the Puerto Rico installation, and no information regarding potential award values or historical contract pricing is available in the posted notice.

Notice text

2 versions

Update #2 · Latest ·

Reason for amendment is to add a CLIN for system start-up. Provide one (1) 7.5 TON Roof Top Unit. Power 460V, 3Phase, 60Hz. Factory assembled, fully charged with R-410A, self contained high and low pressure controls, direct drive, scroll type compressors. Unit shall be delivered to final site in Puerto Rico. Building 37,South Gate Road, Fort Buchanan, Guaynabo PR 00934, to include crane service for unloading at final site.

Update #1 ·

Provide one (1) 7.5 TON Roof Top Unit. Power 460V, 3Phase, 60Hz. Factory assembled, fully charged with R-410A, self contained high and low pressure controls, direct drive, scroll type compressors. Unit shall be delivered to final site in Puerto Rico. Building 37,South Gate Road, Fort Buchanan, Guaynabo PR 00934, to include crane service for unloading at final site.

Similar open opportunities

Opportunity Agency Set-aside Responses due
35 Ton Chiller McAlester Army Ammunition Plant1 C-Tree RdMcAlester, OK 74501 74501 · NAICS 333415 MICC Fort Drum Total Small Business
Air Conditioner Equipment Panama Panama Panama · NAICS 238220 Department of State No set-aside
FCI mckean camp admin air handling unit & installation Pennsylvania 16738, United States · NAICS 333415 Federal Correctional Institution Mckean Total Small Business
Air conditioner Construction and Equipment No set-aside
Repair / Replacement of Mission and Industrial HVAC and Refrigeration Systems 07806 · NAICS 238220 ACC Picatinny No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors