6685--Bath VAMC-Temperature/Humidity Monitoring equipment (VA-26-00026567)

Closed Pre-Solicitation Posted

Solicitation number
36C24226Q0201
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Bath Vamc 76 Veterans Avenue Bath NY 14805

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is seeking to procure temperature and humidity monitoring equipment for the Bath VA Medical Center located in Bath, New York. The procurement aims to standardize monitoring systems across the VA Finger Lakes Health Care System's multiple locations by implementing Rotronic Temperature and Humidity monitoring devices as the system of record. The vendor must provide new monitoring devices in specified quantities and models, with work to be performed Monday through Friday between 8:00 a.m. and 4:00 p.m. EST or at a time mutually agreed upon with the Contracting Officer Representative. This pre-solicitation notice was posted on December 11, 2025, with an initial response deadline of December 18, 2025. The procurement falls under NAICS code 334513 (Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables) and PSC code 6685 (Pressure, Temperature, And Humidity Measuring And Controlling Instruments).

No set-aside designations have been applied to this procurement. The base year device purchase requirements include 66 units of the Rotronic RMS-MLOG-T10-915 with probe, 112 units of the Rotronic RMS-MLOG-B-915, and 125 units of the 915 GATEWAY devices. The pre-solicitation notice does not specify an overall award value or budget range. This is a straightforward equipment procurement with clearly defined product specifications, focusing on the supply of Rotronic-branded monitoring devices without apparent incumbent contractor information disclosed in the pre-solicitation materials. Interested vendors should note the government file 36C24226Q0201_2.docx posted on December 11, 2025, which likely contains additional technical specifications and contracting details.

Notice text

Statement of Work

Temperature and Humidity Monitoring

PROJECT NO. 528A6-24-602

Background:

The VA Finger Lakes Health Care System has established a requirement to use the Rotronic Temperature and Humidity monitoring system; as the system of record for the Bath VA Medical Center, located at, 76 Veterans Ave, Bath, NY 14810.

This will ensure that Bath, Canandaigua and Rochester locations will all operate on the same system of record.

Scope:

Vendor shall provide all the required new humidity and temperature monitoring devices for purchase.

Service Requirements:

Vender shall provide new devices, quantities listed below, for the Bath VAMC.

Vendor shall provide devices as indicated in devices purchase base year

Device Purchase - Base year:

Provide the devices models and required shown below to be used for Bath VA Medical center.

Brand

Quantity

Model

Rotronic

66

RMS-MLOG-T10-915 w/ probe

Rotronic

112

RMS-MLOG-B-915

Rotronic

125

915 GATEWAY

Hours:

Work shall be performed Monday Friday between 8:00 am - 4:00 pm, EST or at a time

predetermined with the Contracting Officer Representative (COR) and Vendor.

Files

File Type Posted
36C24226Q0201_2.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J065 | Viewpoint Software Support and Maintenance North Las Vegas, Nevada 89086, United States · NAICS 811210 Veterans Integrated Service Network 21 No set-aside
Amendment CTX Steam Humidifier Temple, Texas 76504, United States · NAICS 238220 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
Gage, pressure, dial NAICS 334513 Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors