6640 - WSNC IDIQ Respiratory Fit Testing Equipment, Supplies, and Annual Calibrations
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C26026Q0672
- Agency
-
Veterans Integrated Service Network 20
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs seeks to establish a five-year IDIQ contract for respiratory fit testing equipment, supplies, and annual calibrations supporting the Western States Network Consortium (WSNC) across VISNs 17, 19, 20, 21, and 22, with proposals due July 31 and questions due July 15. This is a total small business set-aside, foreclosing competition outside that pool.
Place of performance is the United States. The contractor must provide brand name or equal equipment to the TSI 8048 PortaCount Respirator Fit Tester, capable of testing full-face elastomeric, half-face elastomeric, NIOSH series filtering-facepiece, and disposable N95 respirators, with a maximum fit factor of 10,000 and test completion within 2–5 minutes. Deliverables include fit testing equipment with onboard or external display, internal memory for 1,000+ test results, portable design under 8 pounds, carrying case, particle generator, rechargeable battery, one-year minimum warranty, probe refill kits, isopropyl alcohol, and virtual or video training; optional annual calibration services are included. Individual task orders may not exceed $100,000 each. The price ceiling is $2,000,000 over contract life with a minimum guarantee of $100,000. Offerors must demonstrate minimum three years' experience with similar equipment in VAMCs across large geographic areas and submit CPARS-completed past performance information. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing; PSC is 6640, Laboratory Equipment and Supplies. Payment is via electronic funds transfer, net 30 discount terms. Submit quotes via email to robin.wilson3@va.gov with pricing, relevant experience, and completed representations and certifications.
Notice text
The Department of Veterans Affairs seeks to establishes an Indefinite Delivery Indefinite Quantity (IDIQ) for VA Respiratory Fit Testing Equipment, Supplies, and Annual Calibrations for use within the Western States Network Consortium (WSNC). Contractor shall provide brand name or equal to TSI 8048 PortaCount Respirator Fit Tester.
See attached solicitation for details.
Files
| File | Type | Posted |
|---|---|---|
| Fit Testing 36C26026Q0672.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6640 - WSNC IDIQ Respiratory Fit Testing Equipment, Supplies, and Annual Calibrations | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Test kit,fit,respirat | Construction and Equipment | No set-aside | |
| Fit Test Machine | Air Education and Training Command | Total Small Business | |
| 6550--Cepheid GeneXpert Testing Supplies | Veterans Integrated Service Network 5 | No set-aside | |
| Respirator, air filteri | Construction and Equipment | No set-aside | |
| Respirator,air filt | Construction and Equipment | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity