The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 19 is conducting a market survey for the purchase of one research anaerobic chamber for Rocky Mountain VA Medical Center in Aurora, Colorado, with responses due June 16, 2026 at 4:00 PM Mountain Time.

This is a Sources Sought Notice for market research and planning purposes only; responses cannot be accepted to form binding contracts, and no award will be made on submitted offers. The Government will not compensate respondents for costs incurred in developing information.

The anaerobic chamber must meet specific minimum technical requirements: standard 120V electrical plug, interior dimensions of at least 55" × 31" × 40" (width × depth × height) with maximum depth of 34", interior volume of at least 210 liters, airlock dimensions of at least 12" × 14" × 11" to accommodate sample containers, activated carbon/O₂ palladium cartridge scrubber system, side access panel, and low gas supply alarm and leak detection alarm capabilities.

Interested contractors must submit a Capabilities/Qualifications Statement including an overview of proposed solutions and product descriptions aligned with the salient characteristics list, along with responses to a market research questionnaire. Failure to provide this information will result in the assumption that the entire requirement cannot be met.

Place of performance is Rocky Mountain VA Medical Center, Aurora, Colorado. The contracting office is located in Greenwood Village, Colorado.

Notice text

Sources Sought Notice - Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)

Disclaimer:

This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Information Requested from Industry:

In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.

Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.

Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Research Anaerobic Chamber Purchase for Rocky Mountain VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.

Research Anaerobic Chamber Purchase Qty 1. The offer must meet the following salient characteristics:

Description

Unit

Qty

Anaerobic Chamber

EA

1

Saliant features that are minimum technically required:

Electrical will be standard 120V plug

Interior Dimensions (equal or greater to): 55 x 31 x 40 (width x depth x height). Depth max is 34

Interior volume (equal or greater to): 210 liters

Airlock dimensions (equal or greater to): 12 x 14 x 11 inches (width x depth x height) to accommodate our sample containers

Activated Carbon/O2 palladium cartridge scrubber

Side access panel

Low gas supply alarm and leak detection alarm

Establish

Files

File Type Posted
36C25926Q0526.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J079--36C25927Q0049| Sources Sought on Nanosonics Trophon Units Maintenance for Rocky Mountain Regional VA Medical Center Department of Veterans Affairs Aurora CO 80045 · NAICS 811210 Veterans Integrated Service Network 19 No set-aside
7125--Sterile Storage Cabinets VA Greater Los Angeles (GLA) Healthcare System Los Angeles CA 90073, United States · NAICS 339113 Veterans Integrated Service Network 22 No set-aside
Radiant Heating Panel Replacement Aurora, Colorado 80045, United States · NAICS 238220 Veterans Integrated Service Network 19 Total Small Business
DH10--Amendment 0001 Notice of Intent Sole Source - Labs -RedCap Database Access Services for Rocky Mountain VA Medical Center (RMRVAMC) Rocky Mountain Regional VA Medical Center (Rmrvamc 1700 N Wheeling St, Aurora, CO 80045, United States · NAICS 513210 Veterans Integrated Service Network 19 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors