6540--Multicolor Scan Laser Photocoagulator

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C24426Q0537
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Lebanon VA Medical Center 1700 South Lincoln Ave. Lebanon PA 17042, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 4, is procuring one Multicolor Scan Laser Photocoagulator with accessories for the Lebanon VA Medical Center located in Lebanon, Pennsylvania. This medical device must provide multiple laser wavelengths—532 nm (green), 577 nm (yellow), and 647 nm (red)—to treat various retinal and choroidal pathologies, including diabetic retinopathy and glaucoma. Key requirements include 22 preprogrammed scan patterns with automated positioning capabilities, continuously variable spot sizes ranging from 50 to 500 micrometers in single mode, solid-state or diode laser technology with specified power outputs, and attachable delivery units incorporating SOLIC (Safety Impacts with Low Impact on Cornea) technology. The equipment must operate using standard 115/230V AC power supply with air cooling and emission times ranging from 0.01 to 3.00 seconds. The response deadline for this pre-solicitation notice is May 5, 2026, at 4:00 PM Eastern Time, with solicitation number 36C24426Q0537.

This procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC). The contract requires delivery of the equipment within thirty days of award to the Lebanon VA Medical Center at 1700 S. Lincoln Ave., Lebanon, PA 17042. No incumbent contractor or specific award value is identified in the pre-solicitation notice. The contracting office managing this procurement is located in Pittsburgh, Pennsylvania, and the product falls under Product Service Code 6540 (Ophthalmic Instruments, Equipment, and Supplies) and NAICS code 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing). Qualified vendors should prepare detailed proposals demonstrating their ability to supply equipment meeting all specified technical parameters and delivery requirements.

Notice text

Statement of Need

Multicolor Scan Laser Photocoagulator

Background:

The Lebanon VA Medical Center (LVAMC) has a requirement for one (1) Multicolor Scan Laser Photocoagulator and its accessories.

Scope of Work: The multicolor scan laser photocoagulator provides a variety of laser treatments including pan retinal photocoagulation for diabetic retinopathy and laser iridotomy for glaucoma with a scan slit lamp delivery unit.

Required Features:

532 nm (green) wavelength for treating retinal pathology

577 nm (yellow) laser

647 nm (red) wavelength this wavelength is used for photocoagulation of deep choroidal pathology

Allows the selection of one, two, or three wavelengths, among green, yellow, and red. Will allow selection of the necessary color or combination of colors.

22 preprogrammed scan patterns to allow treatment of varying retinal pathologies.

Will allow automated positioning of the scan pattern to the next region to undergo photocoagulation.

Will include attachable models that incorporate SOLIC (Safety Impacts with Low Impact on Cornea).

The scan spot size will continuously be variable from 100 to 500 µm 50 to 500 µm in single mode.

Must provide momentary increase followed by a plateau and an immediate decrease to provide rapid and high-power laser emission on the scan patterns.

Main Body Specifications:

Laser type: Solid state laser, Diode laser

Wavelength:

Green: 532 nm

Yellow: 577 nm

Red: 647 nm

Power output: Green: 50 to 1,700 mW 1 Yellow: 50 to 1,500 mW Red: 50 to 800 mW 2

Output type: Continuous wave

Emission time: 0.01 to 1.00 s, 2.00 s, 3.00 s*3

Interval time: 0.05 to 1.00 s*4

Aiming beam: Red diode, 670 nm, max. 0.6 mW

Cooling system: Air cooling

Power supply: 115/230 V AC, 50/60 Hz

Power consumption: 400VA

Dimensions/Mass: 300 (VI/) x 480 (D) x 670 (H) mm / 35 kg 11.8 (VI/) x 18.9 (D) x 26.4 (H)" /77.1 lbs

Scan I Single Delivery Unit Specifications

Spot size: 50 to 1,000 µm (slit lamp & attachable deliveries)

Emission pattern: Single

Type: Slit lamp delivery unit

Attachable delivery unit

Dimensions/Mass: slit lamp delivery with table

Delivery:

Delivery shall be within thirty (30) days from the time of award. The Multicolor Scan Laser Photocoagulator shall be delivered to the Lebanon VAMC located at 1700 S. Lincoln Ave., Lebanon, PA 17042; Attn; Warehouse, Biomed will conduct their inspection before delivery to the Optometry Clinic.

Files

File Type Posted
36C24426Q0537_1.docx DOCX document

Notice history

Notice Type Posted
6540--Multicolor Scan Laser Photocoagulator Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity