6515--Stryker Connected OR BRAVoE IP integration and 4K monitors for ORs 1-8. SFVAHCS

Closed Pre-Solicitation Posted

Solicitation number
36C26126R0017
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs VA San Francisco Health Care System San Francisco CA 94121

Notice details come from SAM.gov. Updated .

About this opportunity

This Sources Sought Notice, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21, seeks to identify qualified businesses capable of providing comprehensive construction and supply services for the replacement of operating room integration systems at the San Francisco VA Medical Center. The procurement involves the deinstallation of the existing OR integration system installed in 2012, renovation of operating rooms 1-8 with minimal disruption to ongoing operations, and installation of new Stryker Connected OR BRAVoE IP integration systems with 4K monitors. Key requirements include detailed infection control measures, electrical rerouting, and installation of extensive medical technology equipment including 35 OLED surgical displays, camera systems, wall plate systems, touch panels, and audio/video infrastructure. The Government intends to use responses to determine whether sufficient Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), or small business concerns exist capable of performing the work. Interested vendors must submit a maximum 10-page response by January 9, 2026 at 2:00 PM Pacific Time, providing company name, DUNS number, and small business status; responses to this Sources Sought Notice are voluntary and will not result in contract award, nor will respondents be compensated for their submission costs.

This procurement carries no set-aside designation, and no incumbent contractor or award value is disclosed in the Sources Sought Notice. The project is classified under NAICS Code 339112 (Surgical and Medical Instrument Manufacturing) and Product Service Code 6515 (Medical and Surgical Instruments, Equipment, and Supplies), reflecting the technical nature of the OR integration work. The solicitation number is 36C26126R0017, and responses will be used solely for Government market research purposes to develop acquisition strategy. While no specific budget range or contract value is provided in this notice, the scope of work encompassing equipment replacement across eight operating rooms indicates a substantial procurement. The Government explicitly states that failure to provide requested information or answer any question will be understood as a vendor's statement of inability to provide the service, making complete and thorough responses essential for interested businesses.

Notice text

The purpose of this Sources Sought Notice is to accomplish market research pursuant to FAR

Part 10, and to identify qualified and experienced businesses capable of and interested in

providing the services described in this notice.

This notice is issued solely for information and planning purposes and does not constitute a(n)

Invitation for Bid (IFB), Request for Quotation (RFQ), or Request for Proposal (RFP).

Additionally, there is no obligation or commitment on the part of the Government to acquire any

products or services described within this notice now or in the future. The Government does not

intend to award a contract(s) based solely on the responses to this notice. Respondents are

advised that the Government will not pay for information submitted in response to this notice,

nor will it compensate respondents for any costs incurred in the development/furnishing of a

response. All information provided by interested offerors/vendors is entirely voluntary.

The Government may utilize the information provided by respondents in developing its

acquisition strategy. Respondents will not be notified of the results of the review. Should a

solicitation be issued, the solicitation will be available on Sam.Gov.

Responses to this Sources Sought Notice will be used to determine whether sufficient

SDVOSB/VOSB/small business concerns exist who are capable of performing the work

required by this procurement. FAILURE TO PROVIDE THE REQUESTED

INFORMATION AND/OR ANSWER ANY QUESTION WILL BE UNDERSTOOD BY

VA TO BE A STATEMENT THAT THE VENDOR RESPONDING TO THIS NOTICE IS

UNABLE TO PROVIDE THE SERVICE.

The Department of Veterans Affairs Network Contracting Office (NCO) 21 anticipates a future

procurement for comprehensive construction/supply contract is to ensure the proper replacement of all ORs integration system installed in 2012 located at the San Francisco VA Medical Center. Work is to include proper prep work of each OR to minimize disruption to ongoing OR functionality and staff, deinstallation of all current integration, necessary room renovations in ensure proper functionality for new equipment, and the installation of new integration as well as final testing to ensure all 3rd party systems are formatted and seen properly. Work includes but is not fully limited to any infection control measures necessary.

LIST OF EQUIPMENT:

ITEM NO

DESCRIPTION

QTY

1

HDMI/DVI MIS CAMERA

7

2

HDMI AND DVI BOOM PLATE

14

3

SDI AND DP BOOM PLATE

7

4

ANALOG BOOM PLATE

7

5

SDI AND DP WALL PLATE

7

6

ANALOG BOOM PLATE

14

7

STRYKER SUSPENSION DISPLAY INSTALL KIT DC

28

8

REMOTE PC INSTALL KIT KVM

7

9

IN LIGHT CAMERA INSTALL KIT NEW HD CAMERA

7

10

UNINTERRUPTED POWER SUPPLY UPS

7

11

MIS CAMERA FAIL-SAFE

7

12

OR IN-CEILING SPEAKER PAIR

7

13

CONNECTED OR IP BRAVOE ADJACENT WALL MOUNT FIELD BUILT

7

14

TOUCH PANEL WALL MOUNTED

7

15

TOUCH PANEL USB BAR

7

16

HIGH SPEED USB TRANSFER LOCAL

7

17

HDMI AND DVI WALL PLATE

7

18

AUDIO PACKAGE

7

19

TOUCH PANEL STAND

7

20

CONNECTED OR IP BRAVOE ADJACENT WALL MOUNT FIELD BUILT

1

21

TOUCH PANEL WALL MOUNTED

1

22

TOUCH PANEL USB BAR

1

23

HIGH SPEED USB TRANSFER LOCAL

1

24

AUDIO PACKAGE

1

25

TOUCH PANEL STAND

1

26

HDMI/DVI MIS CAMERA

2

27

HDMI AND DVI BOOM PLATE

3

28

SDI AND DP BOOM PLATE

1

29

ANALOG BOOM PLATE

2

30

HDMI AND DVI WALL PLATE

2

31

SDI AND DP WALL PLATE

1

32

STRYKER SUSPENSION DISPLAY INSTALL KIT DC

4

33

REMOTE PC INSTALL KIT KVM

1

34

IN LIGHT CAMERA INSTALL KIT 4K CAMERA

1

35

UNINTERRUPTED POWER SUPPLY UPS

1

36

MIS CAMERA FAIL-SAFE

1

37

OR IN-CEILING SPEAKER PAIR

1

38

ANALOG WALL PLATE

1

39

Monitor Bracket Upgrade

1

40

OR RENOVATION SERVICES - OR 1

1

41

OR RENOVATION SERVICES - OR 2

1

42

OR RENOVATION SERVICES - OR 3

1

43

OR RENOVATION SERVICES - OR 4

1

44

OR RENOVATION SERVICES - OR 5

1

45

OR RENOVATION SERVICES - OR 6

1

46

OR RENOVATION SERVICES - OR 7

1

47

OR RENOVATION SERVICES - OR 8

1

48

iSuite Installation

1

49

Pkg 32IN 4K OLED Surgical Display

35

50

Pkg OLED Display Cover

35

51

PKG 75FT 5-PIN DC EXTENSION CORD

28

52

SYNK 4K BRACKET ASSEMBLY

28

Description of Requirement: A draft Statement of Work (SOW) is attached.

Responses Should Include:

Company name, DUNS number, and small business status

Interested parties shall not submit more than 10 single-sided, type-written pages using Times

New Roman 12-point font or larger. Published literature may be any number of pages.

Email responses to Alex D. Arter at alex.arter@va.gov no later than 2:00 pm 01/09/2026. For

questions, please contact Alex D. Arter at alex.arter@va.gov.

All information and data received in response to this Source Sought Notice that is marked or

designated as corporate or proprietary information will be fully protected from release outside

the Government.

Responses received after the deadline or without the required information may not be considered.

Since this is a Sources Sought announcement only, evaluation letters will not be issued to any

respondent.

See attached document: SOW SFVAHCS Stryker OR 1-8 Integration Suite.

Files

File Type Posted
36C26126R0017.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Sources Sought Notice/Market Research Project: Renovate SPS Phase 3 Central Virginia VA Healthcare System Cvhcs Richmond Virginia 23249 · NAICS 236220 Veterans Integrated Service Network 6 No set-aside
DA10--Steris Software Connectivity Fresno CA 93703, United States · NAICS 541519 Veterans Integrated Service Network 21 No set-aside
Y1DA--662-27-113 | Construct BLDG 40 Impact Completion Items VA San Francisco Healthcare Sytem San Francisco, California 94121, United States · NAICS 236220 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
9905--Interior Directional Signage Philadelphia VAMC Corporal Michael J. Crescenz VA Medical Center Philadelphia 19104, United States · NAICS 339950 Veterans Integrated Service Network 4 No set-aside
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors