6515--Sources Sought BRAND NAME ONLY Nurse Call System, Rauland / AMETEK, Inc. Responder 5
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25221Q0820
- Agency
-
Veterans Integrated Service Network 12
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334290 Other Communications Equipment Manufacturing
Notice details come from SAM.gov. Updated .
About this opportunity
This notice seeks to upgrade the nurse call system at the Edward Hines, Jr. VA Hospital. Interested parties must have the capability to provide Rauland/AMETEK, Inc. Responder 5 nurse call hardware, software, installation, training, and maintenance services to transition six buildings onto a single Rauland R5 enterprise system. Responses are due by June 18th and must delineate qualifications, business size, product sourcing, and authorization to distribute if applicable. The upgrade aims to standardize communication across approximately 500 beds through reutilization of existing infrastructure and specified requirements for patient, pull cord, nurse stations and code blue/VA network integration.
There is no set-aside designated. The primary NAICS is 334290 for medical equipment and the PSC is J070 for healthcare management systems. No potential incumbents are named but the current systems include various Rauland models from 3-5. The notice does not provide award values or timelines but seeks to upgrade all existing systems at the facility. Key details include requirements for approximately 30 stations types across multiple buildings and a minimum 5-year warranty.
Notice text
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and Small Businesses, including VIP-verified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective vendors relative to the North American Industry Classification System (NAICS) Code 334290 and its small business size standard of 750 employees.
The Edward Hines, Jr. VA Hospital located in Hines, IL has the requirement for a Nurse Call Hardware and Software Upgrade. The Government is requesting that Other Than Small Businesses and Small Businesses, including VIP-verified VOSB or SDVOSB sources respond if it can meet the SOW below and provide the following products on a BRAND NAME ONLY basis (Rauland/AMETEK, Inc. Responder 5 system):
Item
Description
Qty
Unit
0001
Rauland Nurse Call Hardware & Software Lower Level Endoscopy
1
EA
0002
Lower Level Pre/Post Op
1
EA
0003
Lower Level GI Lab
1
EA
0004
Lower Level Pacemaker
1
EA
0005
Lower Level Women's Center
1
EA
0006
1st Floor X-Ray
1
EA
0007
1St Floor Lab
1
EA
0008
1St Floor Emergency Department
1
EA
0009
2nd Floor MICU 2A
1
EA
0010
2nd Floor SICU 2B
1
EA
0011
2nd Floor Surgery
1
EA
0012
Code Blue Operator
1
EA
0013
3rd Floor Clinics
1
EA
0014
4th Floor Clinics
1
EA
0015
5th Floor
1
EA
0016
6th Floor
1
EA
0017
7th Floor
1
EA
0018
8th Floor
1
EA
0019
9th Floor
1
EA
0020
10th Floor East
1
EA
0021
10th Floor West
1
EA
0022
11th Floor
1
EA
0023
12th Floor Dental
1
EA
0024
12th Floor Women's Health
1
EA
0025
13th Floor West
1
EA
0026
13th Floor East
1
EA
0027
14th Floor Sleep Center
1
EA
0028
Rauland Enterprise Perpetual License to enable Census Board, Activity Board, AD (Active Directory), Enterprise Configurator, ADT, Staff Assignments with Sharing Integration, Phone integration, Event Integration, SIP Pillow Speaker Call Back, Overhead Paging, Dashboards and Reports, Staff Awareness and Duress Integration
1
EA
0029
Installation of HW & SW, Engineering, Server Configuration, Project Management, Training
9
EA
0030
Dell PowerEdge R6515 Server
1
EA
0031
To Cover Buildings 12, 113, 128, 200, 217, 221, 228
1
EA
Edward Hines Jr. VA Hospital
Statement of Work: Facility Nurse Call System Upgrade
Description of Use:
The Edward Hines, Jr. VA Hospital is looking to perform a facility wide upgrade of their Nurse Call System to the Rauland R5 Enterprise System. Currently, the Hines VA owns various models of the Rauland Nurse call system ranging from Rauland 3 systems to Rauland 5. The goal of the Hines VA is to upgrade the Nurse Call system for the facility to one uniform system for an enterprise level system. This will allow for the Nurse Call systems to be upgraded to the latest technology and allow for a seamless communication for Nurse Call throughout the facility. This procurement will be an upgrade of existing systems, which shall reutilize existing infrastructure such as conduit, back boxes, raceways, low voltage lighting power supplies, control relays, cross room television control cable, local paging amplifier and speakers and AC power circuits where possible. Additionally, no construction will be involved in this procurement.
Below is a description of the current state of Nurse Call at the Hines VA Hospital.
Current State:
Location
Unit
System
Building 12 2nd Floor
Rauland R4
Building 12 3rd Floor
Rauland R4
Building 113 1st Floor
Blind Rehab Center
Rauland R5
Building 113 2nd Floor
Blind Rehab Center
Rauland R5
Building 128 1st Floor
Spinal Cord Injury
Rauland R5
Building 200 Lower Level
Endoscopy
Rauland R4
Building 200 Lower Level
Pre/Post-Op
Rauland R4
Building 200 Lower Level
Women s Center
Rauland R4
Building 200 1st Floor
X-ray
Rauland R4000
Building 200 1st Floor
Lab
Rauland R4000
Building 200 1st Floor
ED
Rauland R4
Building 200 1st Floor
Cardiac Cath Lab
Rauland R4
Building 200 2nd Floor
Surgery
Rauland R4
Building 200 2nd Floor
SICU
Rauland R4
Building 200 2nd Floor
MICU
Rauland R4
Building 200 3rd Floor
Clinics
Rauland R3
Building 200 4th Floor
Clinics
Rauland R3
Building 200 5th Floor
Rauland R4
Building 200 6th Floor
Dialysis
Rauland R4
Building 200 7th Floor
Rauland R4
Building 200 8th Floor
Rauland R4
Building 200 9th Floor
Rauland R4
Building 200 10th Floor
Rauland Half R4/R3
Building 200 11th Floor
Rauland R4
Building 200 12th Floor
Dental
Rauland R4
Building 200 12th Floor
Women s Health
Rauland R3
Building 217 1st Floor
Extended Care Center
Rauland R5
Building 217 2nd Floor
Extended Care Center
Rauland R5
Building 221 1st Floor
Rauland R4
Building 228 2nd Floor
2 North/South
Rauland R3
Building 228 3rd Floor
Rauland R3
Building 228 4th Floor
Rauland R3
Building 228 5th Floor
Rauland R4000
Bed Count
Unit
Auth Beds
SICU
13
CMICU
13
10W OBS
10
ED
11W TCU
18
11E ACUTE REHAB
10
9 HEM/ONC - TELE
21
8FL GEN/MED - TELE
25
7E MED/SURG - TELE
21
7W STEP DOWN
16
1C SKILLED CARE 1
53
1B SUB-ACUTE REHAB
30
2C SKILLED CARE 2
29
2B HOSPICE
15
RCF
30
2S PSYCH
29
2N RES. RECOVERY
25
BRC
34
SCI-N
29
SCI-S
29
DIALYSIS
30
PREP/RECOVERY
17
Total
497
Minimum Requirements:
Upgrade the Edward Hines, Jr. VA Nurse Call system to the latest Rauland Nurse Call system and Code Blue Components
Solution must be an Enterprise solution meaning the facility should be on one single Nurse Call system to allow the multiple facility buildings to communicate with each other
Solution must be a single set of servers
Housed in a single medical facility using a single installed instance of nurse call software
Centralized management system to manage multiple locations
Ability to configure nursing workflows that can be standardized across all medical facilities
Ability to allow multiple assignments per patient
Patient Station Requirements:
Number of stations are based on current state bed count and include both single and double patient rooms
Code blue/staff assist button
Call cancel button
Call placed LED indicator
Bed out LED indicator
Customizable pillow speaker with receptacle/call cord
Must have capabilities to control hospital grade TV system and overhead lights where existing
Audio microphone and speaker
Capable of multiple call-in priorities
Auxiliary device receptacle with separate call-in priority setting
IV and bed exit alarm capabilities
Capability of disconnecting handset for cleaning
Pull Cord Stations Requirements:
Number of stations dependent on various areas with Nurse Call and number of bathrooms/showers in those areas
Pull cord
Provide audio to bathrooms
Call-in button
Waterproof station
LED corridor lights
Nurse Station Requirements:
Number dependent on current areas with a Nurse Call system
Nurse Console
VoIP Capabilities
32 Customizable one-touch functions
Fully independent console not dependent on PC
Patient or procedure room communications tool
Able to support over 990 possible unique facility-defined call priorities
Customizable one-touch functions
Capable of displaying/answering calls
2 Jack station
37 pin bed receptable
8 pin in-line connector
Dual patient station (dependent on current state, determine at time of installation)
Duty station
Single patient station (dependent on current state, determine at time of installation)
Bed Interface
L-Net T-Tap Module
L-Net Termination Resistor
Pillow Speaker
Remote audio I/O module
Remote audio output station
Staff assist/code blue station
Staff assist station
Staff station
Wall mounting cabinet
IP68 emergency pull cord shower stations
Ability to withstand liquid intrusion
FDA 510k Class I Medical Device
FCC Part 68 compliance for interface to the wireless phone switch
Date encryption to protect PHI
Services:
The vendor shall provide all labor, materials, tools, equipment, management, and transportation to upgrade all existing Nurse Call systems at the Edward Hines, Jr. VA Hospital to the latest Rauland Nurse Call system
Buildings with Nurse call systems are: 113, 128, 200, 217, 221 and 228
These buildings are to be put on a network to communication at an enterprise level
Programming of each station for each area is included
The existing Nurse Call system and Code Blue system shall remain operational during the installation phase of the upgraded Nurse Call system
Provide installation drawings
Provide inventory with serial numbers for all equipment and components installed
Provide network topology/wiring diagrams
Provide technical training for maintenance to at least 4 Biomedical Engineering technicians
Provide facility wide user and super user training for basic operations
All shifts included
Utilize existing infrastructure such as conduit, back boxes, raceways, low voltage lighting power supplies, control relays, cross room television control cable, local paging amplifier and speakers and AC power circuits where possible
All old existing components of the nurse call system that are unused must be removed from the facility
All work must adhere to the latest JCAHO, NFPA, life safety requirements, VA requirements and nurse call equipment manufacturer s specifications
Work must include authorized, certified Rauland specialized technical labor and supervision
Integration Requirements:
Nurse Call system must provide direct SIP trunk integration for immediate voice communication in response to notifications
Server hardware must be included
Windows Server 2016 or latest VA-approved version for server hardware
MS SQL 2016 for all virtual machines
Must connect and function with the current Rauland Nurse Call Code Blue System
Must integrate with the existing R5 nurse call system
Open API for integrations into other systems
Ability to assign Staff from any PC on the Hospital LAN
VA IT TRM approval for any software installed
The software must include licenses that enables Census Board, Activity Board, AD (Active Directory), Enterprise Configurator, ADT, Staff Assignments with Sharing Integration, Phone integration, Event Integration, SIP Pillow Speaker Call Back, Overhead Paging, Dashboards and Reports, Staff Awareness and Duress Integration.
Warranty and Maintenance:
Minimum of 5-year warranty on all hardware components
Minimum of 1-year
Availability of Service:
Local, onsite service available within 2 hours of call
Interested Other Than Small Businesses and Small Businesses including VIP-verified VOSBs and SDVOSBs are required to submit an e-mail delineating:
Qualifications, capabilities, and experience for providing this product;
Business size/Socioeconomic status;
If the product is on the Federal Supply Schedule or the Open Market; and
Memo or correspondence which authorizes distributor to distribute the manufacturer s products (if applicable).
This is not a Request for Proposal or an announcement of a solicitation and no solicitation currently exists. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration.
Responses due are to be submitted by e-mail to Jim Hedman at james.hedman2@va.gov. The information requested must be received no later than 12:00 p.m. CDT on 6/18/2021.
Files
| File | Type | Posted |
|---|---|---|
| 36C25221Q0820.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--Nurse Call Hardware and Software 578A10127 | Award Notice | |
| This notice | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity