About this file

This sources sought notice from the Department of Veterans Affairs seeks information to upgrade the nurse call system at the Edward Hines, Jr. VA Hospital. The notice requests responses from other than small businesses and small businesses, including verified veteran-owned or service-disabled veteran-owned small businesses, to provide Rauland/AMETEK, Inc. Responder 5 nurse call hardware, software, and related installation, training, and maintenance services. Interested parties must submit responses by 12:00 p.m. CDT on June 18, 2021 delineating their qualifications, capabilities, business size, whether products are from the Federal Supply Schedule or open market, and authorization to distribute manufacturer products if applicable. The upgrade aims to transition six buildings onto a single Rauland R5 enterprise system for improved communication and standardization across approximately 500 beds. The scope includes reutilization of existing infrastructure and specified requirements for patient stations, pull cord stations, nurse stations, and integration with code blue systems and VA networks.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Sources Sought Notice

PRODUCT SERVICE CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE

DATE/TIME/ZONE

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

Required Field Contract Opportunity Sources Sought Notice Sources Sought BRAND NAME ONLY Nurse Call System, Rauland / AMETEK, Inc. Responder 5 53214-1476 36C25221Q0820 06-16-2021

12:00 PM

CENTRAL TIME,

CHICAGO, USA

N 334290 Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite 101 Milwaukee WI 53214-1476 Jim Hedman james.hedman2@va.gov

This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and Small Businesses, including VIP-verified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective vendors relative to the North American Industry Classification System (NAICS) Code 334290 and its small business size standard of 750 employees.

The Edward Hines, Jr. VA Hospital located in Hines, IL has the requirement for a Nurse Call Hardware and Software Upgrade. The Government is requesting that Other Than Small Businesses and Small Businesses, including VIP-verified VOSB or SDVOSB sources respond if it can meet the SOW below and provide the following products on a BRAND NAME ONLY basis (Rauland/AMETEK, Inc. Responder 5 system):

Item
Description
Qty
Unit
0001
Rauland Nurse Call Hardware & Software Lower Level Endoscopy
1
EA
0002
Lower Level Pre/Post Op
1
EA
0003
Lower Level GI Lab
1
EA
0004
Lower Level Pacemaker
1
EA
0005
Lower Level Women's Center
1
EA
0006
1st Floor X-Ray
1
EA
0007
1St Floor Lab
1
EA
0008
1St Floor Emergency Department
1
EA
0009
2nd Floor MICU 2A
1
EA
0010
2nd Floor SICU 2B
1
EA
0011
2nd Floor Surgery
1
EA
0012
Code Blue Operator
1
EA
0013
3rd Floor Clinics
1
EA
0014
4th Floor Clinics
1
EA
0015
5th Floor
1
EA
0016
6th Floor
1
EA
0017
7th Floor
1
EA
0018
8th Floor
1
EA
0019
9th Floor
1
EA
0020
10th Floor East
1
EA
0021
10th Floor West
1
EA
0022
11th Floor
1
EA
0023
12th Floor Dental
1
EA
0024
12th Floor Women's Health
1
EA
0025
13th Floor West
1
EA
0026
13th Floor East
1
EA
0027
14th Floor Sleep Center
1
EA
0028
Rauland Enterprise Perpetual License to enable Census Board, Activity Board, AD (Active Directory), Enterprise Configurator, ADT, Staff Assignments with Sharing Integration, Phone integration, Event Integration, SIP Pillow Speaker Call Back, Overhead Paging, Dashboards and Reports, Staff Awareness and Duress Integration
1
EA
0029
Installation of HW & SW, Engineering, Server Configuration, Project Management, Training
9
EA
0030
Dell PowerEdge R6515 Server
1
EA
0031
To Cover Buildings 12, 113, 128, 200, 217, 221, 228
1
EA

Edward Hines Jr. VA Hospital Statement of Work: Facility Nurse Call System Upgrade Description of Use:

The Edward Hines, Jr. VA Hospital is looking to perform a facility wide upgrade of their Nurse Call System to the Rauland R5 Enterprise System. Currently, the Hines VA owns various models of the Rauland Nurse call system ranging from Rauland 3 systems to Rauland 5. The goal of the Hines VA is to upgrade the Nurse Call system for the facility to one uniform system for an enterprise level system. This will allow for the Nurse Call systems to be upgraded to the latest technology and allow for a seamless communication for Nurse Call throughout the facility. This procurement will be an upgrade of existing systems, which shall reutilize existing infrastructure such as conduit, back boxes, raceways, low voltage lighting power supplies, control relays, cross room television control cable, local paging amplifier and speakers and AC power circuits where possible. Additionally, no construction will be involved in this procurement.

Below is a description of the current state of Nurse Call at the Hines VA Hospital.

Current State:

Location
Unit
System

Building 12 – 2nd Floor

Rauland R4

Building 12 – 3rd Floor

Rauland R4

Building 113 – 1st Floor
Blind Rehab Center
Rauland R5
Building 113 – 2nd Floor
Blind Rehab Center
Rauland R5
Building 128 – 1st Floor
Spinal Cord Injury
Rauland R5
Building 200 – Lower Level
Endoscopy
Rauland R4
Building 200 – Lower Level
Pre/Post-Op
Rauland R4
Building 200 – Lower Level
Women’s Center
Rauland R4
Building 200 – 1st Floor
X-ray
Rauland R4000
Building 200 – 1st Floor
Lab
Rauland R4000
Building 200 – 1st Floor
ED
Rauland R4
Building 200 – 1st Floor
Cardiac Cath Lab
Rauland R4
Building 200 – 2nd Floor
Surgery
Rauland R4
Building 200 – 2nd Floor
SICU
Rauland R4
Building 200 – 2nd Floor
MICU
Rauland R4
Building 200 – 3rd Floor
Clinics
Rauland R3
Building 200 – 4th Floor
Clinics
Rauland R3

Building 200 – 5th Floor

Rauland R4

Building 200 – 6th Floor
Dialysis
Rauland R4

Building 200 – 7th Floor

Rauland R4

Building 200 – 8th Floor

Rauland R4

Building 200 – 9th Floor

Rauland R4

Building 200 – 10th Floor

Rauland Half R4/R3

Building 200 – 11th Floor

Rauland R4

Building 200 – 12th Floor
Dental
Rauland R4
Building 200 – 12th Floor
Women’s Health
Rauland R3
Building 217 – 1st Floor
Extended Care Center
Rauland R5
Building 217 – 2nd Floor
Extended Care Center
Rauland R5

Building 221 – 1st Floor

Rauland R4

Building 228 – 2nd Floor
2 North/South
Rauland R3

Building 228 – 3rd Floor

Rauland R3

Building 228 – 4th Floor

Rauland R3

Building 228 – 5th Floor

Rauland R4000

Bed Count

Unit
Auth Beds
SICU
13
CMICU
13
10W OBS
10

ED

11W TCU
18
11E ACUTE REHAB
10
9 HEM/ONC - TELE
21
8FL GEN/MED - TELE
25
7E MED/SURG - TELE
21
7W STEP DOWN
16
1C SKILLED CARE 1
53
1B SUB-ACUTE REHAB
30
2C SKILLED CARE 2
29
2B HOSPICE
15
RCF
30
2S PSYCH
29
2N RES. RECOVERY
25
BRC
34
SCI-N
29
SCI-S
29
DIALYSIS
30
PREP/RECOVERY
17
Total
497

Minimum Requirements:

· Upgrade the Edward Hines, Jr. VA Nurse Call system to the latest Rauland Nurse Call system and Code Blue Components

· Solution must be an “Enterprise” solution meaning the facility should be on one single Nurse Call system to allow the multiple facility buildings to communicate with each other

· Solution must be a single set of servers

· Housed in a single medical facility using a single installed instance of nurse call software

· Centralized management system to manage multiple locations

· Ability to configure nursing workflows that can be standardized across all medical facilities

· Ability to allow multiple assignments per patient

· Patient Station Requirements:

· Number of stations are based on current state bed count and include both single and double patient rooms

· Code blue/staff assist button

· Call cancel button

· Call placed LED indicator

· Bed out LED indicator

· Customizable pillow speaker with receptacle/call cord

· Must have capabilities to control hospital grade TV system and overhead lights where existing

· Audio microphone and speaker

· Capable of multiple call-in priorities

· Auxiliary device receptacle with separate call-in priority setting

· IV and bed exit alarm capabilities

· Capability of disconnecting handset for cleaning

· Pull Cord Stations Requirements:

· Number of stations dependent on various areas with Nurse Call and number of bathrooms/showers in those areas

· Pull cord

· Provide audio to bathrooms

· Call-in button

· Waterproof station

· LED corridor lights

· Nurse Station Requirements:

· Number dependent on current areas with a Nurse Call system

· Nurse Console

· VoIP Capabilities

· 32 Customizable one-touch functions

· Fully independent console not dependent on PC

· Patient or procedure room communications tool

· Able to support over 990 possible unique facility-defined call priorities

· Customizable one-touch functions

· Capable of displaying/answering calls

· 2 Jack station

· 37 pin bed receptable

· 8 pin in-line connector

· Dual patient station (dependent on current state, determine at time of installation)

· Duty station

· Single patient station (dependent on current state, determine at time of installation)

· Bed Interface

· L-Net T-Tap Module

· L-Net Termination Resistor

· Pillow Speaker

· Remote audio I/O module

· Remote audio output station

· Staff assist/code blue station

· Staff assist station

· Staff station

· Wall mounting cabinet

· IP68 emergency pull cord shower stations

· Ability to withstand liquid intrusion

· FDA 510k Class I Medical Device

· FCC Part 68 compliance for interface to the wireless phone switch

· Date encryption to protect PHI Services:

· The vendor shall provide all labor, materials, tools, equipment, management, and transportation to upgrade all existing Nurse Call systems at the Edward Hines, Jr. VA Hospital to the latest Rauland Nurse Call system

· Buildings with Nurse call systems are: 113, 128, 200, 217, 221 and 228

· These buildings are to be put on a network to communication at an enterprise level

· Programming of each station for each area is included

· The existing Nurse Call system and Code Blue system shall remain operational during the installation phase of the upgraded Nurse Call system

· Provide installation drawings

· Provide inventory with serial numbers for all equipment and components installed

· Provide network topology/wiring diagrams

· Provide technical training for maintenance to at least 4 Biomedical Engineering technicians

· Provide facility wide user and super user training for basic operations

· All shifts included

· Utilize existing infrastructure such as conduit, back boxes, raceways, low voltage lighting power supplies, control relays, cross room television control cable, local paging amplifier and speakers and AC power circuits where possible

· All old existing components of the nurse call system that are unused must be removed from the facility

· All work must adhere to the latest JCAHO, NFPA, life safety requirements, VA requirements and nurse call equipment manufacturer’s specifications

· Work must include authorized, certified Rauland specialized technical labor and supervision Integration Requirements:

· Nurse Call system must provide direct SIP trunk integration for immediate voice communication in response to notifications

· Server hardware must be included

· Windows Server 2016 or latest VA-approved version for server hardware

· MS SQL 2016 for all virtual machines

· Must connect and function with the current Rauland Nurse Call Code Blue System

· Must integrate with the existing R5 nurse call system

· Open API for integrations into other systems

· Ability to assign Staff from any PC on the Hospital LAN

· VA IT TRM approval for any software installed

· The software must include licenses that enables Census Board, Activity Board, AD (Active Directory), Enterprise Configurator, ADT, Staff Assignments with Sharing Integration, Phone integration, Event Integration, SIP Pillow Speaker Call Back, Overhead Paging, Dashboards and Reports, Staff Awareness and Duress Integration.

Warranty and Maintenance:

· Minimum of 5-year warranty on all hardware components

· Minimum of 1-year

· Availability of Service:

· Local, onsite service available within 2 hours of call

Interested Other Than Small Businesses and Small Businesses including VIP-verified VOSBs and SDVOSBs are required to submit an e-mail delineating:

· Qualifications, capabilities, and experience for providing this product;

· Business size/Socioeconomic status;

· If the product is on the Federal Supply Schedule or the Open Market; and

· Memo or correspondence which authorizes distributor to distribute the manufacturer’s products (if applicable).

This is not a Request for Proposal or an announcement of a solicitation and no solicitation currently exists. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration.

Responses due are to be submitted by e-mail to Jim Hedman at james.hedman2@va.gov. The information requested must be received no later than 12:00 p.m. CDT on 6/18/2021.