6515--Palmscan Pachymeter/s with Tips

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C24421Q0591
Agency
Veterans Integrated Service Network 4 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
339112 Surgical and Medical Instrument Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
Lebanon VA Medical Center 1700 South Lincoln Avenue 17042 USA

Notice details come from SAM.gov. Updated .

Notice text

This is Pre-Solicitation Notice

The solicitation will be a 100% set-aside for Small Business; an offeror shall be VIP-Verified and registered at sam.gov to be eligible for award. The NAICS Code is 339112, All other personal services or All other support services.

No further information is available now; no response is expected. The solicitation will be posted at on 4/16/2021 0800 Eastern Standard Time.

Thank you for your interest.

PalmScan p2000 Fastpach Pachymeter

Statement of Need

Background:

The Lebanon VA Medical Center (LVAMC) has a requirement for ten (10) PalmScan p2000 fastpach pachymeters, and 1 box of tips per unit, to replace old and failing pachymeters. These devices are portable, battery operated units used to measure Central Corneal Thickness (CCT) of human eyes. These are used on every patient provided care in Optometry.

Scope of Work:

The device is a portable, battery operated, unit used to measure corneal thickness (CT) of human eyes. These are used on every patient provided care in Optometry.

Salient Characteristics of the p2000 Pachymeter Unit:

Battery Operated and Portable

50 Mhz Probe

Accuracy +/- 4 um

Precision +/- 1 um

Resolution +/- 1 um

Range: Corneal/Epithelium Thickness 250-1000 um

Sampling Frequency 200 MHz

Utilizes disposable pachytips

Not autoclavable or immersable

Acoustic Output Measurements:

Maximum Acoustical Output - 0.189

Maximum Acoustical Output 1.99

Mechanical Index 0.155

Palmscan Pachymeter Tip Covers:

Must fit and integrate with the p2000 Pachymeter unit.

Must be disposable

Additional Information:

The PalmScan was chosen for its accuracy, portability, functionality and durability.

Delivery:

Delivery shall be within thirty (30) days from the time of award. The Pachymeters and accessories shall be delivered to the Lebanon VAMC located at 1700 S. Lincoln Ave., Lebanon, PA 17042; Attn; Warehouse. BioMedical Engineering will need to perform a safety check and enter the equipment in to the system for annual Preventive Maintenance (PM) checks. Placement in the LVAMC clinic shall be coordinated through the Chief, Optometry, BioMed, and/or Contracting Officer Representative.

Attachments

Files attached to this notice, newest first
File Type Posted
36C24421Q0591_1.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
6515--Palmscan Pachymeter/s with Tips Award Award Notice
6515--Palmscan Pachymeter/s with Tips Latest solicitation Solicitation
6515--Palmscan Pachymeter/s with Tips This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity