6515--Mobile UV Disinfection Device

Closed Pre-Solicitation Posted

Not the latest version. See the latest pre-solicitation from .

Solicitation number
36C26226Q1159
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs VA Long Beach Healthcare System Long Beach CA 90822, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

VA Long Beach Healthcare System is issuing a sources sought notice and RFI due July 30, 2026, to identify qualified vendors for two mobile UV disinfection devices equivalent to the Xenex MXSUV1-FTXCT, with firm fixed price award anticipated. This is pre-solicitation market research only and does not constitute a binding solicitation or contract offer.

Place of performance is VA Long Beach Healthcare System, 5901 East 7th Street, Long Beach, California 90822. Equipment must be FDA-approved Class II Whole Room Microbial Reduction Devices under 21 CFR 880.6510, capable of emitting broad-spectrum pulse UV light in the germicidal range (240–315 nm) for healthcare environments. Respondents must be Original Equipment Manufacturers, authorized dealers, authorized distributors, or authorized resellers with OEM authorization letters; remanufactured or gray market items are not acceptable.

The acquisition includes software licensing, one-year maintenance package, on-site service and training, factory replacement accessories, refurbished-to-new replacement emitter exchange, portal usage, cloud-based storage, and discounted Surfacide repairs. NAICS code 339113 (Surgical Appliance and Supplies Manufacturing) applies with a small business size standard of 800 employees. Respondents must address 19 capability and compliance questions covering SOW requirements, business size status, manufacturer authorization, COTS compliance, FDA clearance, lead times, pricing, SAM.gov registration, and federal contract holdings. Responses should be submitted via email to Hestia.Sim@va.gov. No set-aside is anticipated.

Notice text

THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT/RFI DESCRIPTION

This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.

STATEMENT OF WORK

Introduction: Long Beach Veterans Affairs, located at 5901 E. 7th St, Long Beach, CA 90822 is soliciting and intends to award at a firm fixed price contract to purchase two (2) Mobile UV Disinfection Devices equivalent to Xenex s MXSUV1-FTXCT. This purchase must include software licensing, upgraded safety assurance, reporting and archiving, factory replacement accessories, on-site service and training, refurbished to new replacement emitter exchange, portal usage and cloud-based storage and discounted Surfacide repairs.

Place of Performance:

VA Long Beach Healthcare System

5901 E. 7th Street

Long Beach, CA 90822

Deliverables:

Line Item

Description

Qty

UOM

0001

Mobile UV Disinfection Device equivalent to Xenex MXSUV1-FTXCT including software licensing, 1-year maintenance package, and on-site service and training

2

EA

0002

Trade-in Credit (if applicable) Xenex MXSUV1-FTXCT

1

EA

NOTE: Potential quoters must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are or equal , a description of the salient characteristics is outlined below. It is quoter s responsibility to demonstrate its quote meeting the salient physical and functional characteristics included in this solicitation. If the quote does NOT demonstrate, the offer will be considered non-responsive. The interested parties bear full responsibility to ensure their submission demonstrates to the government that they can satisfy the requirement by providing the brand name or equal to the supplies being requested.

VAAR 852.212-71 Gray Market and Counterfeit Items clause applies on this acquisition. No remanufacturers or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contains the signature of an authorized official for the manufacturer. If the interested contractor fails to provide a signed letter from the OEM (unless the contractor is the OEM), the contractor s response will be deemed non-responsive and will not be considered for award.

Salient Characteristics:

Must be FDA-approved as a Class II Whole Room Microbial Reduction Device under 21 CFR 880.6510 (intended specifically for healthcare environment), meaning it must comply with FDA performance, safety, and labeling requirements applicable to devices reviewed under Product Code QXJ.

Must be capable of emitting broad-spectrum pulse UV light with the germicidal range (240-315 nm) to achieve whole-room microbial reduction.

Must support wireless or equivalent automated data synchronization to enable real-time reporting and software updates.

Must have integrated safety features to prevent operation in occupied areas.

Must be constructed with durable, damage-resistance materials suitable for frequent transport in healthcare environments.

Must be designed for mobility.

Must have a mechanism that protects the light-emitting components during transport.

Must operate without warm-up or cool-down delays that impact workflow efficiency.

Must include a base year warranty and support package that provides minimum of:

Replacement of consumable components as necessary for routine device operation and maintenance

Replacement prats required for maintenance and repairs performed by the original equipment manufacturer (OEM) trained and certified technician.

Manufacturer-provided repair or replacement of the device if it fails to operate due to a manufacturing defect.

Remote diagnostic capabilities and telemetry monitoring to support troubleshooting, performance verification, and maintenance planning.

Software and firmware updates for all device components during the warranty period.

24/7 customer support availability for technical assistance.

Predictive maintenance monitoring and proactive alerts regarding potential service needs or component wear.

Access to manufacturer s performance-management platform or portal for device data, reporting, and usage analytics.

Monthly performance and compliance reports summarizing device utilization and operational outcomes.

Online training resources to support user competency.

The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.

If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements. For instances where your company cannot meet the SOW requirement(s), please explain. For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW?

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?

(11) Please indicate whether your product conforms to the requirements of the Buy American Act?

(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.

(13) What is estimated life span of your solution? What support/services does that entail?

(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.

(15) Does your organization offer a leasing solution? Please elaborate.

(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.

Responses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Thursday, July 30, 2026, by 10AM Pacific Local Time.

All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

Files

File Type Posted
36C26226Q1159.docx DOCX document

Notice history

Notice Type Posted
6515--Mobile UV Disinfection Device Latest pre-solicitation Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
6530--NX EQ Environmental Disinfection Systems Pulsed Xenon UV Light (VA-27-00012571) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick No set-aside
Q999--MO | Surgical Laser Service | 663 5 year IDIQ : 2/11/2027-2/10/2032 VA Puget Sound Health Care System Seattle Division Seattle WA 98108, United States · NAICS 621999 Veterans Integrated Service Network 20 No set-aside
6550--Cepheid GeneXpert Testing Supplies Beckley Vamc Clarksburg Vamc Vamhcs Washington Vamc · NAICS 325413 Veterans Integrated Service Network 5 No set-aside
J046--Reverse Osmosis PM NAICS 811210 Veterans Integrated Service Network 21 Total Small Business
7G21--BNE Hillrom Voalte Nurse Call Requirement (New Work) NAICS 541519 VA Technology Acquisition Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity