About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 22 is issuing a sources sought notice and request for information regarding convective warming systems, with responses due July 21, 2026. This is a pre-solicitation notice for information and planning purposes only; responses cannot form a binding contract. The VA seeks qualified sources capable of supplying equipment equivalent to the ICU Medical Level 1 Convective Warmer-12 (Model# L1-CW-120V) under NAICS 339113 (800-employee size standard).
The requirement specifies 20 units for delivery to the VA Greater Los Angeles Healthcare System at 11301 Wilshire Boulevard, Los Angeles, California. Equipment must include a hose-end temperature control to continuously measure air temperature before reaching the patient, a safety circuit providing independent means to discontinue heater power, and the ability to draw ambient-temperature air through a High Efficiency Particulate Air (HEPA) filter. The system must offer four temperature settings: 37°C, 40°C, 43°C, and ambient temperature air.
Respondents must address 19 questions covering manufacturing or distribution capabilities, business size status and certifications, FDA clearance, lead times, pricing, SAM.gov registration, and compliance with the Non-Manufacturer Rule, Buy American Act, and subcontracting limitations. Responses should be submitted by email to Contract Specialist Melissa Ramirez at Melissa.Ramirez8@va.gov no later than July 21, 2026 at 10:00 AM Pacific Time. Submission of pricing, delivery timelines, market information, and capabilities is encouraged for planning purposes. The government will use responses to inform subsequent acquisition decisions, which may include additional RFIs or formal solicitations.
Notice text
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.
SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).
DISCLAIMER
This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SOURCES SOUGHT/RFI DESCRIPTION
This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.
The Department of Veterans Affairs (VA) is seeking sources capable of convective warming system equivalent to brand ICU Medical.
CLIN
DESCRIPTION
QTY
UOM
0001
ICU Medical Level 1 Convective Warmer-12 Model# L1-CW-120V equal
20
EA
SALIENT CHARACTERISTICS
CLIN 0001 ICU Medical Level 1 Convective Warmer-12 Model# L1-CW-120V equal Quantity: 20EA
Must come with a hose-end temperature control to continuously measure air temperature before reaching the patient.
Must come with safety circuit providing an independent means to discontinue power to the heater.
Must be able to draw ambient-temperature air through a High Efficiency Particulate Air (HEPA) filter.
Must come equipped with 3 outlet temperature settings, to provide flexibility in patient treatment: 37°C, 40°C, and 43°C.
Must come with 4th temperature setting of ambient temperature air.
The list of Draft convective warming system characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.
If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Incomplete responses to the questions below this notice will not be accepted. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:
(1) Submit your capabilities statement illustrating how your organization can/cannot meet the SALIENT CHARACTERISTICS. For instances where your company cannot meet the SALIENT CHARACTERISTICS, please explain. For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.
(2) Please review the SALIENT CHARACTERISTICS and provide any additional feedback or suggestions. If none, please reply as N/A.
(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.
(4) Is your company considered small under the NAICS code identified in this RFI?
(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?
(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).
(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.
(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?
(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?
(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?
(11) Please indicate whether your product conforms to the requirements of the Buy American Act?
(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.
(13) What is estimated life span of your solution? What support/services does that entail?
(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.
(15) Does your organization offer a leasing solution? Please elaborate.
(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).
(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.
(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.
(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.
Responses to this notice shall be submitted via email to Melissa.Ramirez8@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, July 21st, 2026 by 10:00 AM Pacific Local Time.
All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.
Files
| File | Type | Posted |
|---|---|---|
| 36C26226Q1103.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Pre-Solicitation | |
| 6515--Level 1 Convective Warming System | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 6515--Anesthesia Units Extend due date/time | Veterans Integrated Service Network 1 | No set-aside | |
| Amendment CTX Steam Humidifier | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| J065 | Viewpoint Software Support and Maintenance | Veterans Integrated Service Network 21 | No set-aside | |
| J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832. | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| 6515--Inari FlowTriever Retrieval Aspiration System (5) Intent to Sole Source Base Four (4) Option Years VA Pittsburgh Healthcare System | Veterans Integrated Service Network 4 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity