6515--Large Bone Drills
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 36C24626Q0555
- Agency
-
Veterans Integrated Service Network 6
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Place of performance
- Salisbury VA Health Care System Salisbury NC 28144
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Network Contracting Office 6 is conducting a market research sources sought notice for Large Bone Power Drill Sets to support the Salisbury VA Medical Center/Health Care System and two affiliated health care centers in North Carolina. The procurement seeks orthopedic rotary handpieces with dual triggers capable of drilling, reaming, sawing, and burring for heavy-duty orthopedic applications, featuring a twist-lock collet mechanism and hermetically sealed components. The required drill system must operate on 13.2V sterilizable lithium-ion battery packs, include specific attachments such as AO drill attachments, Hudson modified trinkle instruments, and micro sagittal saw attachments, and meet precise performance specifications including 153 in-lbs reaming torque and 1500 RPM drill speed. The system must also include a rapid multi-battery charger capable of charging four batteries simultaneously with exact dimensional and weight specifications. This is a sources sought notice for market research purposes only, not a formal solicitation, and interested vendors must submit capability statements by May 1, 2026 at 12:00 PM EDT to kamilah.nye@va.gov with the subject line "Sources Sought Large Bone Power Drill, 36C24626Q0555-1."
This procurement carries no set-aside designation and no incumbent contractor is identified in the notice. Vendors must submit detailed capability information including company credentials, NAICS Code 339112 verification, SAM.gov UEI number, business size classification, place of manufacture, country of origin documentation, and authorized distributor letters if applicable, with the small business size standard established at 1,000 employees. The notice does not disclose estimated award values or specific quantities of units required. The Government has indicated it will not pay for submitted information and reserves the right to determine its acquisition strategy or pursue alternative procurement approaches based on vendor feedback received during this market research phase.
Notice text
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposals, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited.
INTRODUCTION: The Salisbury VA Medical Center/Health Care System (SVAHCS) has a new requirement for Large Bone Power Drill Set. This requirement is needed for Salisbury VA Medical Center (VAMC), Kernersville Health Care Center (HCC), and Charlotte Health Care Center (HCC).
The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified vendors who can provide the following item:
SALIENT CHARACTERISTICS:
Large Bone Drills
Must be Orthopedic rotary handpiece with dual trigger. The dual trigger rotary drill must be able to drill, ream, saw, and burr while delivering the torque necessary for heavy-duty reaming applications.
Must have collet mechanism twist-lock collet ring that allows user to rotate left or right to quickly unlock, remove and snap in new attachment.
Handpiece must have hermetically sealed components
Must have as attachments:
Dual trigger wire collet, small, 0.6-1.8mm
Dual trigger pin collet, medium 2.0-3.2mm
Small AO drill attachment
¼ drill chuck with key
Hudson modified trinkle drill attachment
Hudson modified trinkle reamer attachment
¼ reamer chuck with key
Micro sagittal saw attachment
Large lithium-ion battery
Small lithium-ion battery
System must use lithium-ion battery packs 13.2 V that can be sterilized before surgery.
Must include lithium-ion battery charger with small footprint and rapid battery processing.
Battery charger must meet dimensions.
Width 16
Height 4
Depth 6.5
Weight 4 lbs.
Must be able to charge 4 batteries at a time.
Must have clear confirmation of charging level
Dimensions height 15.0 cm, width 2.75 cm, depth 11.8 cm
Mass 710 gm as single drill handpiece without battery
Must have reaming torque of 153 in-lbs
Must have drill speed of 1500 RPM
Must have protection ratings of: IPX6, IPX8, IPX9 for cleaning and sterilization purposes
Must have all characteristics in single drill handpiece
Must include container sterilization.
OBJECTIVE:
Enable fast, secure attachment changes using the drill s proprietary twist collet ring mechanism, which allows left/right rotation to lock/unlock attachments for quick removal and re connection.
Standardize powered instrumentation with 13.2 V sterilizable lithium ion battery packs for consistent power delivery and workflow flexibility (small and large battery options).
The applicable North American Industrial Classification System (NAICS) code assigned to this effort is 339112 with the Small Business Size Standard of 1,000 employees. If the Government determines there are qualified vendors with this requirement, a solicitation may be published and posted on the Contracting Opportunities website https://sam.gov/content/home . The Government will use this information solely to determine the appropriate acquisition strategy for this procurement.
This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.
Respondents to these Sources Sought shall provide the following information:
Capability statement
Name and address of company
NAICS Code
SAM.gov UEI number
Business size (large, small, VOSB, or SDVOSB)
Place of manufacture (if the requirement involves supplies)
Identify applicable socioeconomic categories and any pertinent information which demonstrates the firm s ability to meet above requirement.
An authorized distributor letter if the interested party is not the manufacturer
Country of origin for all equipment.
All responses shall be submitted no later than 12:00 PM EDT Friday 01 May 2026. All interested parties should respond, in writing via email to kamilah.nye@va.gov. No telephone inquiries will be accepted.
Please title the subject line for all responses as: Sources Sought Large Bone Power Drill, 36C24626Q0555-1.
Locations where deliveries are needed:
Salisbury VA Health Care System:
Salisbury VA Medical Center
1601 Brenner Ave.
Salisbury, NC 28144
Kernersville Health Care Center (HCC)
1625 Kernersville Medical Parkway
Kernersville, NC 27284
Charlotte Health Care Center (HCC)
3506 W. Tyvola Rd.
Charlotte, NC 28208
Files
| File | Type | Posted |
|---|---|---|
| 36C24626Q0555.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--Large Bone Power Set | Award Notice | |
| 6515--Large Bone Power Set | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity