The Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office, is seeking sources capable of providing a Video Laryngoscope Workstation with Wireless Connection. The workstation must meet specific salient characteristics, including camera resolution, screen size, battery life, and wireless connectivity. This Request for Information (RFI)/Sources Sought notice is issued solely for information and planning purposes, not for a formal solicitation. Responses to this RFI will be used by the government to make appropriate acquisition decisions, and a solicitation may be published after review of the submissions. Responses are not considered offers and cannot form a binding contract.
This RFI has no set-aside designation, and the government is seeking sources classified under NAICS code 339112 (Surgical and Medical Instrument Manufacturing) with 1,000 or fewer employees. The notice does not mention any potential incumbents or current contractors. The government has not provided any details on potential award values or budgets. The deadline for responses to this RFI is August 9, 2024 at 4:00 PM Pacific Time.
Notice text
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.
THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SOURCES SOUGHT/RFI DESCRIPTION
This is NOT a solicitation announcement. This is a Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this Sources Sought/RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought/RFI, a solicitation announcement may be published. Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.
The Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office, is seeking sources who can possibly provide Video Laryngoscope Workstation with Wireless Connection. that at a minimum meet the brandname and/or can possibly provide an equal product for the VA Medical Center San Diego, CA.
Brandname Information:
Manufacturer & Part Number(s): Insight, ARJ13302RU
Type: Rusch IS-PF2 Workstation w/Wireless Connection
Equal to product name: Video Laryngoscope Workstation with Wireless Connection
Manufacturer & Part Number(s): Insight, ARJ100RU
Type: Rusch IS6 Handle
Equal to product name: Handle
Manufacturer & Part Number(s): Insight, ARJ0004RU
Type: Rusch Cart
Equal to product name: Cart
Salient Characteristics:
Must have Video Laryngoscope Handle Camera Resolution: 1,000,000 pixels (1280 x 720) field of view: >60-degree Illumination: LED light source
Must have Sheath: Material Polycarbonate Sterile, single use
Must have a have Small Screen Display: 3.5-inch LCD medical resistance touch screen, High-Definition color; Resolution: 640 x 480
Must have Rotating Angle: Forward 60 degrees/Backward 90 degrees/Leftward 90 degrees/Rightward 180 degrees
Must have Built in Battery: Rechargeable lithium battery, working time 4 hours fully charged
Workstation must have wireless connection module
Must have a large screen workstation for visualization. Key features include: - 13.3" screen monitor- Thin Film Transistor LCD color, Cable or cable free connection, Rechargeable built-in battery
Must have Connection Port: Type-C port, HDMI port, headphone port, power socket
Must have Built in Battery: Rechargeable lithium battery, working time 6 hours fully charged and Battery Recharging Time: Up to 6.5 hours
Must have Cable Length: 2 meters
Must have NFC Module Connection Type: Near Field Communication (NFC) wireless with a Connection Distance:
Files
| File | Type | Posted |
|---|---|---|
| S05 Request for Information RFI Video Laryngoscope.pdf | ||
| 36C26224Q1686.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--IS-PF2 WorkStation | Award Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| HD endoscope_gastroscope solution | Veterans Integrated Service Network 5 | No set-aside | |
| 7G21--BNE Hillrom Voalte Nurse Call Requirement (New Work) | VA Technology Acquisition Center | No set-aside | |
| Q999--MO | Surgical Laser Service | 663 5 year IDIQ : 2/11/2027-2/10/2032 | Veterans Integrated Service Network 20 | No set-aside | |
| 6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) | VA Strategic Acquisition Center Frederick | Service-Disabled Veteran-Owned Small Business | |
| J065--Karl Storz Support Services IDIQ VISN 23 | Veterans Integrated Service Network 23 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity