6115--Mobile Diesel Generator 552 - Emergency Management Funds

Closed Pre-Solicitation Posted

Solicitation number
36C25026Q0732
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Dayton VA Medical Center 4100 West Third Street

Notice details come from SAM.gov. Updated .

About this opportunity

Veterans Integrated Service Network 10, Department of Veterans Affairs, is preparing a sources sought notice for a 500-kilowatt mobile diesel generator with a response deadline of July 17, 2026; no set-aside is anticipated. Place of performance is the Dayton VA Medical Center, 4100 West Third Street, Dayton, Ohio, and funding comes from Emergency Management Funds.

The generator must operate at 60 Hz with multivoltage output capabilities (480/277, 240/139, and 208/120 volts) and be powered by a heavy-duty diesel engine meeting EPA Tier 4 Final emission standards and CARB certification for non-road mobile applications. Sound levels must not exceed 72 dB(A) at 7 meters under SAE J1074 measurement procedures at 110% prime load. The unit requires a 100-amp charging alternator with three-phase random wound coastal insulation protection and Class H insulation with Class F temperature rise, permanent magnet excitation, anti-condensation heaters rated at 120/240V 1.2 kW on board at 480V, and ISO 8528-5 transient response compliance. Additional mandatory requirements include 110% spill containment of onboard engine fluids, 0.6667 pitch winding configuration, UL 1446 recognized Class H insulation, and single-point access to accessory connections. Interested vendors must submit an email response to Luke A. Turner (luke.turner@va.gov) by July 17, 2026 at 10:00 AM Eastern Time, including contact information, socioeconomic status designation, and Unique Entity Identifier (UEI) number.

Notice text

Attachment(s):

Â

The purpose of this sources sought is to identify the competition pool for the item of supply described in the above attachment(s). If your company is capable of and interested in supplying this item, please send an email to luke.turner@va.gov before the closing of this notice.

Please include the following information with your inquiry:

Contact information,

Socio-economic status (e.g., small business) and

Unique Entity Identifier (UEI) Number.

***END OF SOURCES SOUGHT***

Files

File Type Posted
Salient Characteristics.xlsx XLSX spreadsheet
36C25026Q0732.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--Emergency Switchgear Repairs PWS 539 Cincinnati Vamc 3200 Vine Street, United States · NAICS 811310 Veterans Integrated Service Network 10 No set-aside
J030--Diesel Generator Service Department of Veterans Affairs James J. Peters Medical Center Bronx, New York 10468, United States · NAICS 811310 Veterans Integrated Service Network 2 No set-aside
Generator Maintenance Service Hampton, Virginia 23667, United States · NAICS 238220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
J061--TVHS Generator PM/Bank Testing Base+4 VA Tennessee Valley Healthcare System Murfreesboro Alvin C. York Campus Murfreesboro, Tennessee 37129, United States · NAICS 238210 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business
Generator, alternating Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity