6115--Mobile Diesel Generator 552 - Emergency Management Funds
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25026Q0732
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 335312 Motor and Generator Manufacturing
- Place of performance
- Dayton VA Medical Center 4100 West Third Street
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Veterans Integrated Service Network 10, Department of Veterans Affairs, is preparing a sources sought notice for a 500-kilowatt mobile diesel generator with a response deadline of July 17, 2026; no set-aside is anticipated. Place of performance is the Dayton VA Medical Center, 4100 West Third Street, Dayton, Ohio, and funding comes from Emergency Management Funds.
The generator must operate at 60 Hz with multivoltage output capabilities (480/277, 240/139, and 208/120 volts) and be powered by a heavy-duty diesel engine meeting EPA Tier 4 Final emission standards and CARB certification for non-road mobile applications. Sound levels must not exceed 72 dB(A) at 7 meters under SAE J1074 measurement procedures at 110% prime load. The unit requires a 100-amp charging alternator with three-phase random wound coastal insulation protection and Class H insulation with Class F temperature rise, permanent magnet excitation, anti-condensation heaters rated at 120/240V 1.2 kW on board at 480V, and ISO 8528-5 transient response compliance. Additional mandatory requirements include 110% spill containment of onboard engine fluids, 0.6667 pitch winding configuration, UL 1446 recognized Class H insulation, and single-point access to accessory connections. Interested vendors must submit an email response to Luke A. Turner (luke.turner@va.gov) by July 17, 2026 at 10:00 AM Eastern Time, including contact information, socioeconomic status designation, and Unique Entity Identifier (UEI) number.
Notice text
Attachment(s):
Â
The purpose of this sources sought is to identify the competition pool for the item of supply described in the above attachment(s). If your company is capable of and interested in supplying this item, please send an email to luke.turner@va.gov before the closing of this notice.
Please include the following information with your inquiry:
Contact information,
Socio-economic status (e.g., small business) and
Unique Entity Identifier (UEI) Number.
***END OF SOURCES SOUGHT***
Files
| File | Type | Posted |
|---|---|---|
| Salient Characteristics.xlsx | XLSX spreadsheet | |
| 36C25026Q0732.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Request for Information (RFI) - CONUS Generator Maintenance | Federal Emergency Management Agency | Total Small Business | |
| J061--Generator Inspection Service and Routine Maintenance - | Veterans Integrated Service Network 6 | No set-aside | |
| J061--Thompson Power Generator Service RFI Intent to Sole Source | Veterans Integrated Service Network 9 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| 750kW Emergency Diesel Generator (EDG) Rental (PSNS&IMF) | Naval Supply Systems Command | Total Small Business | |
| Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's | Land and Maritime | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity