4810--36C242-25-AP-2574|528-25-3-8893-0573|S-21 mid pressure condensate tank and pump set
Closed Pre-Solicitation Posted
- Solicitation number
- 36C24225Q0579
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 332919 Other Metal Valve and Pipe Fitting Manufacturing
- PSC
- 4810 Valves, Powered
- Place of performance
- Department of Veterans Affairs Albany VA Medical Center Albany, New York 12208, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs (Veterans Health Administration, Veterans Integrated Service Network 2) is seeking a replacement condensate tank and pump set for the Samuel S. Stratton VA Medical Center in Albany, New York. The procurement involves supplying a specific Shipco model 454-PCD Duplex condensate unit with a 57-gallon receiver and two NEMA 1 mechanically alternating pumps capable of 45GPM @ 40 PSI performance. The project supports the VA's mission of providing healthcare for veterans in the capital region and upstate New York. The solicitation is classified under NAICS code 332919 for Other Metal Valve and Pipe Fitting Manufacturing and Product Service Code 4810 for Powered Valves. Interested contractors are advised to contact Contracting Officer Corey Swinton at Corey.Swinton@va.gov, with responses due by May 5, 2025, at 4 PM Eastern Time.
The pre-solicitation notice indicates no specific set-aside designations for this procurement, suggesting the opportunity is open to all qualified contractors. The detailed equipment requirements include comprehensive specifications such as a control panel with NEMA magnetic starter, integral breaker, auto/off selector switches, LED pilot lights, and various technical components like pressure gauges, ball valves, and check valves. The total system requires one condensate tank, two pumps, and multiple associated mechanical and electrical components. While no specific award value is mentioned, the complexity of the technical specifications suggests this is a specialized equipment procurement with precise engineering requirements. The project is located at the Albany VA Medical Center and appears to be a targeted replacement of existing infrastructure to maintain medical facility operational capabilities.
Notice text
Statement of Work
S-21 Replacement condensate tank
Albany Stratton VAMC
Introduction Stratton VAMC s mission is to provide world class healthcare for veterans in the capital region and upstate New York.
Background /Objective Replacement condensate tank and pump set
Parts contractor shall provide.
One (1) Shipco model 454-PCD Duplex condensate unit 57-gal receiver with 3-inch inlet.
Two (2) NEMA 1 mechanically alternating pumps 117PF vertical conditions 45GPM @ 40 PSI 2 NPSH inlet 1.5 inch Discharge 3HP 460 V 3PH 3500 RPM JM Frame TEFC Motors
Two (2) suction inlet valves for service
One (1) dial thermometer
One (1) NEMA 1 control Panel mounted and wired with liquid tight conduit. Nema Magnetic Starter with integral braker. With auto, off selector switches and push to test for each pump. Led pilot lights single point power connection. Through door circuit brakers with lock out tag out accessories.
One (1) 3-inch NPT low profile inlet basket strainer.
Two (2) 0-60 psi pressure gauges.
Two (2) ¼ inch steel ball valves
Two (2) gauges coil syphons
Two (2) 1.5-inch Steel Spring Check valves.
Files
| File | Type | Posted |
|---|---|---|
| 36C24225Q0579.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| J043--Damen Building Vacuum Condensate System Rebuild | Veterans Integrated Service Network 12 | No set-aside | |
| J065--Medical Gas Prevenative Maintenance and Service Albany VAMC | Veterans Integrated Service Network 2 | No set-aside | |
| Z1DA--460-26-999 | Condenser Water Piping Modification | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| N044--replace air separator and relocate | Veterans Integrated Service Network 6 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity