4710--duct containment

Closed Pre-Solicitation Posted

Solicitation number
36C26226Q1168
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs Greater Los Angeles VA Healthcare System Los Angeles CA 90073
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

Veterans Integrated Service Network 22 (Department of Veterans Affairs) is conducting a sources sought and RFI for duct containment exhaust system components, with responses due July 23, 2026, by 10:00 AM Pacific Time. This is not a solicitation and does not constitute a binding contract; responses are requested solely for market research and planning purposes under FAR 15.201(e).

The requirement is to supply exhaust system components made of thermoplastic material for a Level 2 biosafety cabinet used for biohazard sample processing and analysis at Greater Los Angeles VA Healthcare System in Los Angeles, California. Components specified include LABCONCO-manufactured items: one 12-inch blower transition adapter, one 12-inch thermoplastic duct (10 feet), five 10-inch thermoplastic ducts (10 feet each), five 90-degree elbow couplings, two female duct couplings, three 12-inch male duct couplings, one flexible duct connection, one thermoplastic duct reducer, one 2 HP spectrum coated steel blower (230V, up to 2800 CFM), and one back draft damper. Vendors may propose equal or equivalent alternatives.

Responses must address 19 specific information requirements, including business size status under NAICS 326122 (Plastics Pipe and Pipe Fitting Manufacturing, 500-employee threshold), manufacturer versus distributor status, COTS designation, Buy American Act compliance, lead times, pricing for market research, and Federal Supply Schedule contract availability. Submit responses to sam.choo@va.gov. Responses will be archived 60 days after the response date and used to inform future acquisition decisions.

Notice text

THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT/RFI DESCRIPTION

This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 326122 Plastics Pipe and Pipe Fitting Manufacturing (Size standard of 500 employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.

The purpose of this contract is to have a vendor to provide exhaust system components in support of a biosafety cabinet used for Level 2 biohazard sample processing and analysis at Greater Los Angeles VA Healthcare System, Los Angeles, CA. These components, made of Thermoplastic material, ensure proper ventilation and containment for VA Medical Research studies. The vendor shall provide following requirements or Equal:

Blower Transition Adapter

MFR: LABCONCO

MFR SKU: 7003400

Diameter: 12"

Rectangular Inlet dimension: 7 X 13.5

Qty: 1

Thermoplastic Duct 12" dia.

MFR: LABCONCO

MFR SKU: 5602000

Duct Nominal Diameter: 12

Length: 10 ft.

Qty: 1

Thermoplastic Duct 10" dia.

MFR: LABCONCO

MFR SKU: 7027200

Duct Nominal Diameter: 10

Length: 10 ft.

Qty: 5

90-Degree Elbow Coupling

MFR: LABCONCO

MFR SKU: 7027300

Duct Nominal Diameter: 10"

Equivalent Resistance in Feet of Straight Duct: 20

Qty: 5

Female Duct Coupling

MFR: LABCONCO

MFR SKU: 7027500

Duct Nominal Diameter: 10"

Qty: 2

Flexible Duct Connection

MFR: LABCONCO

MFR SKU: 7034200 / 30182-500

Compatible Duct Diameter: 10"

Qty: 1

Male Duct Coupling

MFR: LABCONCO

MFR SKU: 7067300

Diameter: 12"

Qty: 3

Thermoplastic Duct Reducer

MFR: LABCONCO

MFR SKU: 5606100

Duct Connection Diameters, Size: 10" x 12"

Duct Nominal Diameter: 12

Qty: 1

Spectrum Coated Steel Blower

MFR: LABCONCO

MFR SKU: 177250200

Material: Coated Steel Blower

CFM: Up to 2800

Power: 2 HP

Nominal Inlet Duct Diameter Diameter: 12"

Electrical: 230V, 50/60 Hz, 1ph/3ph

Qty: 1

Back Draft Damper

MFR: LABCONCO

MFR SKU: 3858800

Qty: 1

If your company is interested and capable of providing the required supplies/services, you MUST provide the information indicated below OR your intent, interest to participation, and information provided will not be considered as valid for research purposes.

Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements. For instances where your company cannot meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please explain. For instances where your company can meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of DRAFT/SALIENT CHARACTERISTICS/SOW?

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company:

(i) Does not exceed 500 employees (or 150 employees for the Information Technology Value Added Reseller exception to NAICS Code 541519, which is found at § 121.201, footnote 18);

(ii) Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;

(iii) Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice; and

(iv) Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) of this section.

(11) Please indicate whether your product conforms to the requirements of the Buy American Act? Please indicate if manufacturer is/will be US domestic Small Business / US Domestic Large Business / Foreign.

(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.

(13) What is estimated life span of your solution? What support/services does that entail?

(14) Does your organization offer a leasing solution? Please elaborate.

(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.

(19) Please provide County of origin, manufacturing site information.

Responses to this notice shall be submitted via email to sam.choo@va.gov. Telephone responses will not be accepted. Responses must be received no later than Thursday, July 23, 2026 by 10:00 AM PST.

All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

Files

File Type Posted
36C26226Q1168.pdf PDF
36C26226Q1168.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J073--FY 27 Services | Kitchen Exhaust Hood and Ductwork Cleaning | Base + 4 | 561 East Orange VA Medical Center 385 Tremont Avenue East Orange, New Jersey 07018, United States · NAICS 811310 Veterans Integrated Service Network 2 No set-aside
Duct assy NAICS 333998 Naval Supply Systems Command No set-aside
Flexible duct IDIQ Bremerton, Washington, United States · NAICS 332999 Land and Maritime Total Small Business
Hose, air duct NAICS 332999 Land and Maritime Service-Disabled Veteran-Owned Small Business
Hose assembly, air duct NAICS 332999 Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity