4310--Optical Lab Air Compressor Replacement Project, IND

Closed Pre-Solicitation Posted

Solicitation number
36C25026Q0162
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Indianapolis VA Medical Center - Optical Lab Indianapolis, Indiana 46241, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10, specifically the Indianapolis VA Medical Center, is seeking two industrial air compressors through this Sources Sought Notice and Request for Information. The agency requires two Ingersoll Rand RS55I, 75HP, 138 PSI Contact Cooled Rotary Screw air compressors or equivalent units, each independently capable of providing 335 CFM of continuous air supply to support the VA Optical Lab. Key requirements include integrated air-drying systems on each unit, variable speed/rotary design (preferred but not mandatory), and fully turn-key project management and installation services encompassing removal and scrapping of existing equipment, transportation, rigging, utility hookups, and system integration. Contractors must be capable of providing comprehensive installation services and may be evaluated based on their experience with similar equipment, GSA contract availability, business classification, and manufacturer credentials. The deadline for submitting responses is Wednesday, December 17, 2025, at 4:30 PM EST, with submissions directed to Contracting Officer Brooke Hansen at Brooke.Hansen@va.gov and referencing solicitation number 36C25026Q0162.

This procurement carries no set-aside designation and does not identify any current incumbents. Responses must include standard business information such as DUNS number, NAICS code (333912 for Air and Gas Compressor Manufacturing), business size classification, small business type if applicable, GSA contract number and expiration date if available, manufacturer information for non-manufacturer concerns, and country of origin. The solicitation does not specify a contract award value or budget range in the pre-solicitation notice. The project is classified under Product Service Code 4310 (Compressors and Vacuum Pumps) and will be performed at the Indianapolis VA Medical Center located at 5610 Dividend Rd, Suite B, Indianapolis, IN 46241. The government has indicated that an optional preventative maintenance program may be solicited in a future procurement, and potential vendors are encouraged to schedule on-site pre-proposal visitations to ensure accuracy in their proposals.

Notice text

This is a REQUEST FOR INFORMATION and SOURCES SOUGHT for TWO Industrial Air Compressors

Contractors that deem themselves capable of meeting the requirement shall provide the below information to Brooke Hansen, Contracting Officer, at Brooke.Hansen@va.gov no-later-than Wednesday, December 17, 2025 at 4:30PM, EST, referencing (36C25026Q0162). Responses shall include: (1) Business Name and Address, (2) GSA Contract Number and expiration date, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size SMALL or LARGE (6) Type of Small Business (if applicable): service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard (8) Country of Origin. If the concern is the manufacture and the sole distributor, please provide documentation to that effect.

Please see requirements below:

Indianapolis VA Medical Center, located at 5610 Dividend Rd, STE B, Indianapolis, IN 46241, is requesting the purchase of TWO Ingersoll Rand RS55I, 75HP, 138 PSI Contact Cooled Rotary Screw with Total Air System or equivalent.

Project minimal specification requirements:

a. ON-SITE pre-proposal visitation by potential vendor is available, to ensure accuracy in the vendor s proposal to the government.

b. Two (2) units, each unit independently able to continuously provide the minimally acceptable air demand requirements (335 CFM) of the VA Optical Lab, installed in tandem, to allow continuous, uninterrupted supply of air, regardless of which air compressor is operational. The VA currently owns a 500-gallon (approximate) air storage tank.

c. Each air compressor unit shall include an integrated air-drying system.

d. Variable speed/rotary design is preferred, but not mandatory.

e. Fully turn-key project management/installation

- Removal and scrapping of two (2) existing units IR model IRN40H-CC-HV air compressors

- Transportation and all rigging of outgoing & incoming equipment

- Integration and exhaust duct work required to place both new air compressor units in the most acceptable location in the VA s mechanical room- core ductwork is present.

- All utilities hook-up and/or modification required to optimize new air compressor requirements. Presently, the VA has one (1) 100A/60V safety switch, and one (1) 200A/240V safety switch.

- All drain requirements of the new air compressors.

- All plumbing & material requirements to tie into or modify present air supply lines (4 copper) to optimize new equipment replacement/location.

- Relocation of existing 500-gallon (approximate) air storage tank to optimize new equipment replacement/location.

f. Awarded vendor must be able to offer an optional, Preventative Maintenance program (to be solicitated and awarded later) to support this equipment for the OEM estimated life of these air compressors.

Files

File Type Posted
36C25026Q0162.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
4130--Chiller Compressor Replacement at the Edward Hines Jr. VA Hospital (Hines) Building 228 Edward Hines Jr. VA Hospital (Hines) 5000 S. Fifth Ave. Hines, Illinois 60141, United States · NAICS 238220 Veterans Integrated Service Network 12 No set-aside
Gallup Indian Medical Center - Air Compressor System Demo and Replacement Gallup, New Mexico 87301, United States · NAICS 333912 Indian Health Service No set-aside
Valve, compressor NAICS 333912 Land and Maritime No set-aside
Rotor, air compressor NAICS 333912 Land and Maritime No set-aside
J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832. See Solicitation · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities