36C25026Q0162.docx

DOCX document 17 KB Posted

Attached to
4310--Optical Lab Air Compressor Replacement Project, IND
Solicitation number
36C25026Q0162
Issued by

About this file

This is a Sources Sought Notice for the Indianapolis VA Medical Center's Optical Lab Air Compressor Replacement Project. The Department of Veterans Affairs is seeking information from potential contractors for the procurement of two Ingersoll Rand RS55I, 75HP, 138 PSI Contact Cooled Rotary Screw air compressors or equivalent. Key requirements include two independent units capable of providing 335 CFM of air demand, integrated air-drying systems, and a fully turn-key project management and installation process that involves removing existing air compressors, transportation, rigging, utility hookups, and system integration.

Contractors must submit responses by December 17, 2025, at 4:30 PM EST to Brooke Hansen, referencing solicitation number 36C25026Q0162. Submissions should include business details such as name, GSA contract number, point of contact information, DUNS number, business size (small or large), small business type (if applicable), manufacturer information, and country of origin. The project is classified under NAICS code 333912 and Product Service Code 4310, with the place of performance at 5610 Dividend Rd, STE B, Indianapolis, IN 46241. An optional preventative maintenance program may be solicited in a future procurement.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Optical Lab Air Compressor Replacement Project, IND

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
49037
SOLICITATION NUMBER*
36C25026Q0162
RESPONSE DATE/TIME/ZONE
12-17-2025 4:30PM EASTERN TIME, NEW YORK, USA
ARCHIVE
15 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
4310
NAICS CODE*
333912
CONTRACTING OFFICE ADDRESS
Department of Veteran Affairs

Network Contracting Office 10

5500 Armstrong Rd.

Battle Creek MI 49037

POINT OF CONTACT*

Contract Specialist Brooke Hansen brooke.hansen@va.gov Phoned inquiries will not be accepted.

PLACE OF PERFORMANCE

ADDRESS
Indianapolis VA Medical Center - Optical Lab

5610 Dividend Rd, STE B

Indianapolis IN

POSTAL CODE
46241
COUNTRY
US

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
Department of VA
AGENCY CONTACT’S EMAIL ADDRESS
brooke.hansen@va.gov
EMAIL DESCRIPTION
Contract Specialist

DESCRIPTION

This is a REQUEST FOR INFORMATION and SOURCES SOUGHT for TWO Industrial Air Compressors Contractors that deem themselves capable of meeting the requirement shall provide the below information to Brooke Hansen, Contracting Officer, at Brooke.Hansen@va.gov no-later-than Wednesday, December 17, 2025 at 4:30PM, EST, referencing (36C25026Q0162). Responses shall include: (1) Business Name and Address, (2) GSA Contract Number and expiration date, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size SMALL or LARGE (6) Type of Small Business (if applicable): service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard (8) Country of Origin. If the concern is the manufacture and the sole distributor, please provide documentation to that effect.

Please see requirements below:

Indianapolis VA Medical Center, located at 5610 Dividend Rd, STE B, Indianapolis, IN 46241, is requesting the purchase of TWO Ingersoll Rand RS55I, 75HP, 138 PSI Contact Cooled Rotary Screw with Total Air System or equivalent.

Project minimal specification requirements:

a.ON-SITE pre-proposal visitation by potential vendor is available, to ensure accuracy in the vendor’s proposal to the government.
b.Two (2) units, each unit independently able to continuously provide the minimally acceptable air demand requirements (335 CFM) of the VA Optical Lab, installed in tandem, to allow continuous, uninterrupted supply of air, regardless of which air compressor is operational. The VA currently owns a 500-gallon (approximate) air storage tank.
c.Each air compressor unit shall include an integrated air-drying system.
d.Variable speed/rotary design is preferred, but not mandatory.
e.Fully turn-key project management/installation
-Removal and scrapping of two (2) existing units IR model IRN40H-CC-HV air compressors
-Transportation and all rigging of outgoing & incoming equipment
-Integration and exhaust duct work required to place both new air compressor units in the most acceptable location in the VA’s mechanical room- core ductwork is present.
-All utilities hook-up and/or modification required to optimize new air compressor requirements. Presently, the VA has one (1) 100A/60V safety switch, and one (1) 200A/240V safety switch.
-All drain requirements of the new air compressors.
-All plumbing & material requirements to tie into or modify present air supply lines (4” copper) to optimize new equipment replacement/location.
-Relocation of existing 500-gallon (approximate) air storage tank to optimize new equipment replacement/location.
f.Awarded vendor must be able to offer an optional, Preventative Maintenance program (to be solicitated and awarded later) to support this equipment for the OEM estimated life of these air compressors.
*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .