Integrated Force Plate System
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- FA527019QA068
- Agency
- Pacific Air Forces Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 452319 All Other General Merchandise Stores
- PSC
- Not on record
- Place of performance
- Torii Station Okinawa, Japan Japan
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Purchase of an integrated force plate system with installation and training at Torii Station, Okinawa Japan. See solicitation for further details
Quotations and questions can be sent to SSG Matthew Morgan - matthew.morgan.43@us.af.mil
.
Update #1 ·
Purchase of 3D Force Plate system with installation and training at Torii Station, Okinawa Japan.
Interested Parties can contact SSG Matthew Morgan - matthew.morgan.43@us.af.mil
The solictitation is expected to be posted late August 2019
Force Plate System Overview
-System software for the force plate measurement system that integrates 3D Force Plate measurement system with synchronized highspeed HD color video and displays userselected variables and statistical comparisons in realtime.
- A complete solution for integrating with Olympic lifting stations or jumping stations- complete with a surrounding floor panels to provide a large, safe area for testing and training.
- A portable solution for 3D force measurement that provides several features for educational, tactical, and sport assessment purposes: A large landing surface for a portable plate; 2000 vertical load capacity to handle large impacts; HallEffect sensors to handle large loads and minimize drift; and very easy to setup.
- Methods in analysis that are extremely reliable and valid and have demonstrated data integrity through numerous independent, peer reviewed articles allowing us to know we are capturing accurate reliable data.
- System software shall provide diversity in test collection and analysis options to include:
Standard Jump, Landing and Olympic Weightlifting tests with full analysis, including:
Repeated Jump Tests, countermovement and squat jumps, many single leg hops and jumps, drop jump and landings, isometric lift tests, and dynamic weight lifting exercises
- Force plate system and software shall include fully integrated on board video capture and replay capable of providing data streams fully integrated and synchronized with up to 5 HD Color video at frames rates to 150+ fps. Shall provide a real force vector overlay, and user customized information to be displayed on instant replay. Shall also be available to the user for post processing, analysis and sharing.
- Shall have a video export and reporting feature which allows users to export customized mp4 videos for sharing or PDF reports complete with screenshots and usergenerated comments.
- Data files shall be able to be stored in Excelfriendly ascii format, allowing users to export data to 3rd party software for statistical analysis. The system shall allow access to the raw data.
- The system shall allow for real time display capability for use with teaching, coaching, and live feedback.
Force Plate Minimum Specifications
Force Measurement:
- Fz capacity: 2000 lb (8900 N)
- Fx, Fy capacity: 1000 lb (4450 N),
- Mz capacity : 10000 inlb (1100 Nm)
- Mx, My capacity: 25000 inlb (2825 Nm)
- Lowest Natural Frequency: > 100 Hz
- Output type: RS232/USB
- Highest data rate RS232: 200 data sets/sec
- Higher data rate USB: 1200 data sets/sec
- Size: Approx. 30" x 40" x 4.9" (762mm x 1016 mm x 124 mm) (+/- 10% of size)
- Weight: Approx. 50 lbs/ 22.67 Kg
- A low weight force plate with the option of no mounting required. Option to be able to be wheeled for plate portability when needed, have a rugged nonskid surface that is wellsuited for evaluating tactical, sport and weight lifting
techniques. Option to be mounted as well.
Force Plate Minimum PC Specifications.
Windows 10 64 Bit (on 500 Gb SSD HD); >1TB second or external HD for video storage
- Intel i7 quad core processor or better
- 16 Gb RAM for up to two cameras; 32 Gb for 3 or more cameras
- 1 Gb dedicated graphics card
- Minimum of 2 cameras for video capture with the option to integrate 45 in the future in needed. Cameras and force plate must be able to be sync signals.
.
Attachments
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA527019QA0680001 SF 30.pdf | ||
| Attachment 2 - Price List.pdf | ||
| Solicitation Amendment - FA527019QA0680001.pdf | ||
| Attachment 1 - Force Plate SOW.pdf | ||
| Attachment 1 - Force Plate SOW.pdf | ||
| Attachment 2 - Price List.pdf | ||
| Solicitation - FA527019QA068.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Integrated Force Plate System | Award Notice | |
| Integrated Force Plate System | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity