122FW Fort Wayne, IN B770 Fire Station Addition and Renovation

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
W50S7W-25-B-A001
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Indiana 46809, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army National Guard is seeking market research for a renovation and addition project at the 122d Fighter Wing's Fire Crash/Rescue station in Fort Wayne, Indiana. The project encompasses renovating the existing facility and constructing a 6,200 square foot addition using conventional construction methods. Key contract requirements include implementing ICC 500-2020 Storm Shelter Design standards, achieving USGBC LEED Certification, and upgrading critical systems such as roof, lightning protection, exterior envelope, fire protection, and HVAC. Interested small businesses must submit a comprehensive response by February 4, 2025, at 5:00 PM EST, including a statement of intent, completed Sources Sought Response Form, three-year project history, resource and personnel details, and bonding capability documentation. The government will evaluate responses to determine whether sufficient small business competition exists for the procurement.

The opportunity is currently set aside exclusively for small businesses, with an estimated project value between $5 million and $10 million. Contractors must demonstrate experience with storm shelter design requirements and sustainable construction practices, and provide documentation of individual and aggregate bonding capabilities. Respondents are required to submit their comprehensive response as a single PDF via email to specified Air Force contacts, using a specific subject line format. If inadequate small business participation is identified during this market research phase, the procurement may be converted to an unrestricted competition. The project falls under the NAICS code 236220 for Commercial and Institutional Building Construction and will utilize the PSC code Z2JZ for Repair or Alteration of Miscellaneous Buildings.

Notice text

THIS IS A SOURCES SOUGHT POSTING. This is NOT a solicitation, but market research to determine potential sources for this project including interested small business sources. This notice is for planning purposes only.  

Not responding to this sources sought does not preclude participation in any future solicitation, should one be issued. It is the responsibility of the interested parties to monitor the SAM.gov website for additional information pertaining to this sources sought.

The purpose of this requirement is to renovate and construct an addition to existing Fire Crash/Rescue station, building 770 located at the 122d Fighter Wing in Fort Wayne, IN using government provided designs/specs/drawings.  The project includes repair/renovation of the roof, lightning protection, exterior envelope, fire protection system, and HVAC systems. This project includes the construction of an additional 6,200 SQFT to the Fire Crash/Rescue station using conventional construction methods to accommodate the mission of the facility. The project will include ICC 500-2020 Design and Construction of Storm Shelters requirements and Sustainable Design Requirements - USGBC LEED Certification.

RESPONSE INFORMATION:

The magnitude of this project will be between $5,000,000 and $10,000,000.  Interested concerns will provide this office, in writing via single PDF, a notice stating their positive intent to submit a bid as a prime contractor no later than 4 Feb 2025 at 5:00PM EST.

This notification, which shall not exceed seven typewritten pages, must include:

(1) positive statement of intent to bid as a prime contractor

(2) a completed Sources Sought Response Form

(3) a listing of projects completed during the past three years, both for government and private industry (the type of project, dollar value, contract number, location, and Government Point of Contact are to be included; indicate if you were prime or subcontractor, and if subcontractor, provide the name and Point of Contact for the prime contractor), including projects you have demonstrated experince with ICC 500-2020 Design and Construction of Storm Shelters requirements and Sustainable Design Requirements - USGBC LEED Certification

(4) a brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract, and

(5) single project & total aggregate bonding capability in the form of a letter from the Surety.

In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted.

Information shall be provided via emails to both: lisa.crose@us.af.mil & travis.kraick@us.af.mil

Include the following in the subject line "Sources Sought_W50S7W25BA001_Company Name".

Files

File Type Posted
Sources Sought response template.pdf PDF

Notice history

Notice Type Posted
Security Lighting Latest solicitation Solicitation
Airfield Security Lighting Improvements Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
REQUEST FOR INFORMATION (RFI) / MARKET RESEARCH NOTICE RELATED TO SEVERAL UPCOMING PROJECTS at WRIGHT-PATTERSON AFB, OHIO Wright Patterson AFB, Ohio 45433, United States · NAICS 236220 ENDIST Louisville No set-aside
PKA Relocatable Facility FE Warren AFB, Wyoming 82005, United States · NAICS 332311 Global Strike Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors