This document is a Sources Sought Synopsis from the U.S. Army Corps of Engineers, Portland District, seeking interested parties for future Master Ship Repair Agreement(s) (MSRA) to provide repair and maintenance services for the Dredge ESSAYONS and Dredge YAQUINA vessels under NAICS code 336611.

The key details are: The government intends to establish MSRAs with capable repair facilities and is seeking information on interested parties, their socioeconomic status, capabilities, and qualifications. Submission requirements include providing a statement of capability, documentation of relevant past performance, and completing a qualification checklist. The anticipated schedule includes a government shipyard site review in June-July 2024, a job order invitation for bid in late June-early July 2024, and bid opening in August 2024, with award by 15 August 2024. Small businesses are encouraged to respond, and the point of contact for small business assistance is provided.

View the file

Other files

File Type Posted
Essayons_Qualification_Checklist.pdf PDF
GeneralRequirements.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

YAQUINA QUALIFICATION

CHECKLIST

PHYSICAL REQUIREMENTS

Overall: YES NO Not less than 20 feet of water depth at Mean Low Water Level A distance of not less than 250 feet between fore and aft tie off kevels

Dry-dock: YES NO Lift capacity of 2,001 long tons Clearance between wing walls of not less than 85’-0” for job orders requiring lowering of drag arms.

Clearance between wing walls of not less than 58’0” for job orders NOT requiring lowering of drag arms

Keel block height of not less than 6’-0”

Facilities: YES NO 50’-0” x 16’-0” clear dock working area;

Live load pier capacities not less than those prescribed in AASHTO H15-44 as certified by a Professional Engineer

Not less than 400A, 480V AC, 3-phase, 60 cycle continuous electrical service with GFCI and phase protection

Compressed air service that can provide a minimum of 100 psig through a portable air dryer and 1 1/2” hose to the vessel’s air connection.

Potable water service capable of providing 90psi, 50gph at not less than 1000 gallons per day.

Receiving tank or other suitable service in place to receive effluent from the vessel sewage plant.

Receiving tank or other suitable service in place to receive effluent from the vessel gray water overboard flange connections.

Fire protection water at 50 psig and 400 gallons per minute. Fresh water is not required for this service.

Crane shall be capable of accessing any area above the vessel and have a lift capacity of 8,800 lbs minimum over the entire area.

A minimum of 600 square feet of temporary office space available for use by the Government within 500 yards of the proposed Berth and Dry-dock facilities