Y26-700_Drawings.pdf

PDF 9 MB Posted

Attached to
Administration Center Redistricting Renovation
Solicitation number
Y26-700
Issued by
Orange County, Orlando City, Florida

About this file

This construction documents file pertains to the Orange County Administration Center Redistricting Renovation (Project Y26-700) in Orlando, Florida, a Level 2 alteration project involving approximately 1,586 square feet of office reconfiguration on the 3rd and 5th floors of the existing county administration building. The project scope includes demolition and construction of several new walls, new flooring, new ceilings, and cosmetic upgrades to the 3rd Floor Conference Room to accommodate two Orange County Commissioners. The renovation encompasses mechanical, electrical, fire protection, and technology systems work coordinated by the design team of Rhodes+Brito Architects (605 E. Robinson St, Suite 750, Orlando, FL), Kaleidoscope Interior Design, and Bobes Associates (150 Circle Drive, Maitland, FL). Sealed bids are being accepted electronically through the OpenGov e-Procurement Platform with submission deadlines of November 18, 2025 (updated to November 25, 2025), at 4:00 pm EST, with a non-mandatory pre-bid meeting scheduled for October 23, 2025, at 10:30 am via Microsoft Teams. Questions must be submitted by November 4, 2025, at 5:00 pm EST through the OpenGov platform. The project requires substantial completion within 120 consecutive calendar days and final completion within 150 consecutive calendar days from the Notice to Proceed date.

The estimated project cost is $460,000.00, with a required bid bond or alternative surety of 10% of the total estimated contract amount. The project will operate within the existing Orange County infrastructure framework, including the Lenel OnGuard access control system, and must comply with the Florida Building Code (2023 Edition), Florida Fire Prevention Code (2021 Edition), National Electrical Code (2020 Edition), and ANSI/TIA standards. Progress payments will be processed with 5% retainage for contracts exceeding $200,000. Contractors must be registered with the E-Verify system and comply with drug-free workplace certification and anti-human trafficking attestation requirements. Telecommunications infrastructure must utilize specific manufacturers including Siemon and Corning products in accordance with BICSI standards. The facility is required to remain operational throughout the construction period, with all dust, noise, and circulation issues coordinated with the owner prior to work commencement.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

THIS PROJECT IS THE RENOVATION OF 3RD AND 5TH

FLOOR SPACE IN THE EXISTING ORANGE COUNTY

ADMINISTRATION BUILDING TO ACCOMMODATE THE

TWO ORANGE COUNTY COMMISSIONERS. RENOVATION

WILL INCLUDE DEMOLISHING AND CONSTRUCTING

SEVERAL NEW WALLS, NEW FLOORING, AND CEILINGS.

IN ADDITION, THE 3RD FLOOR CONFERENCE ROOM

WILL RECEIVE COSMETIC UPGRADES.

PROJECT SCOPE VICINITY MAP

PROJECT DESIGN TEAM

RHODES+BRITO ARCHITECTS 605 E.

ROBINSON ST, SUITE 750

ORLANDO, FL 32801

PH. (407) 648-7288

CONTACT: LORI GODBOLD, AIA, NCARB

ARCHITECTURE

KALEIDOSCOPE INTERIOR DESIGN

SUITE

CITY, FL 12345

PH: (407) 702-8208

CONTACT: MANDY WANNEN, LEED SP, EDAC, ALEP

INTERIORS

BOBES ASSOCIATES

150 CIRCLE DRIVE

MAITLAND, FL 32751

PH: (407) 628-0882

CONTACT: GUS BOBES JR, P.E.

FIRE

PROTECTION

A C CT T SEH IR

AR0014284

BOBES ASSOCIATES

150 CIRCLE DRIVE

MAITLAND, FL 32751

PH: (407) 628-0882

CONTACT: GUS BOBES JR, P.E.

MECHANICAL

BOBES ASSOCIATES

150 CIRCLE DRIVE

MAITLAND, FL 32751

PH: (407) 628-0882

CONTACT: GUS BOBES JR, P.E.

ELECTRICAL

BOBES ASSOCIATES

150 CIRCLE DRIVE

MAITLAND, FL 32751

PH: (407) 628-0882

CONTACT: GUS BOBES JR, P.E.

TECHNOLOGY

NICOLE H. WILSON CHRISTINE MOORE

District 1 Commissioner District 2 Commissioner

MAYRA URIBE MARIBEL GOMEZ CORDERO

District 3 Commissioner District 4 Commissioner

KELLY MARTINEZ SEMRAD MICHALE "MIKE" SCOTT

District 5 Commissioner District 6 Commissioner

JERRY L. DEMMINGS

COUNTY MAYOR

BOARD OF COUNTY COMMISSIONERS

ORANGE COUNTY ADMINSTRATION CENTER

REDISTRICTING RENOVATION

CONSTRUCTION DOCUMENTS

08/27/2025

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY GOVERNMENT

400 EAST SOUTH STREET, SUITE 500

ORLANDO, FL 32801

G000

DATE SUBMISSION / REVISION NO.

r h o d e s + b r i t o A R C H I T E C T S

A

A101

A2

A711

A2

A711

MATERIALS LEGEND

DRAWING FORMAT

DIMENSIONING SHEET NUMBERING

100 SF

A101

A711A scale:

drawn:

check:

date:

project no: 2001.001

01.01.01 date

Client Logo and

Project Title

ALL

REPRODUCTION

AND

INTELLECTUAL

PROPERTY

RIGHTS

RESERVED

CLIENT LOGO

HERE

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

19.02

TYP

TYP

G1

E1

C1

A1 A3

C3

E3

G3

A5 A7 A9

C5

EACH SHEET IS DIVIDED INTO A GRID. AN ALPHA-NUMERIC GRID COORDINATE SYSTEM IS USED TO ORGANIZE THE DRAWING TITLES

DRAWING TITLES ARE NUMBERED ACCORDING TO ITS LOCATION ON THE GRID. THE LOWER LEFT HAND CORNER GRID OF THE

DRAWING IS USED AS THE IDENTIFICATION NUMBER (SEE DIAGRAM).

COLUMN CENTERLINE

PARTITIONS ARE DIMENSIONED TO FACE OF STUDS, FACE OF CMU AND FACE OF

BLOCK UNLESS INDICATED OTHERWISE

DIMENSIONS ARE INDICATED ON DRAWINGS, DO NOT SCALE DRAWINGS

6.

7.

PARTITION

KEYNOTE

REFERENCE

ELEVATION

REFERENCE

REVISION

IDENTIFICATION

PARTITION TYPE

IDENTIFICATION

WINDOW TYPE

REVISION NUMBER

(REFER TO TITLE

BLOCK)

TARGET ELEVATION

TARGET DESCRIPTION

WINDOW DESIGNATION

(REFER TO WINDOW

SCHEDULE)

REFERENCE NUMBER

PARTITION TYPE

(REFER TO PARTITION

TYPE DETAILS)A

GRAPHIC

SCALE

INDICATES FEET

WHEN A ROOM/BUILDING/OBJECT CENTERLINE IS INDICATED, ONLY ONE SIDE OF

ELEMENT MAY BE DIMENSIONED

PARTITIONS WITH FINISH FACE FLUSH WITH FINISH FACE OF COLUMN WILL NOT BE

DRAWN ON SMALL SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER

SCALE DRAWINGS.

COLUMN CENTERLINE

PARTITION FINISH FACE ON COLUMN OR GRID LINE WILL NOT BE DIMENSIONED ON

SMALL SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE

DRAWINGS.

PARTITIONS CENTERED ON COLUMNS OR GRID LINES WILL NOT BE DIMENSIONED ON

SMALL SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE

DRAWINGS.

5.

4.

PARTITION

3.

B. AS DIMENSIONED

COLUMN CENTERLINE

PARTITION

DOOR LOCATION

DOORS ARE LOCATED BY ONE OF THE FOLLOWING:

A. ONE JAMB FACE LOCATED BY A PARTITION AT RIGHT ANGLE.

2.

1.

PARTITION

DOOR

SINGLE INTERIOR

ELEVATION

REFERENCE

RESTROOM

ACCESSORY

IDENTIFICATION

DOOR NUMBER

SPOT

ELEVATION

REFERENCE

TRUE

NORTH ARROWDOOR NUMBER

(SEE DOOR SCHEDULE)

TARGET ELEVATION

ACCESSORY TYPE

(REFER TO RESTROOM

ACCESSORY SCHEDULE)A

ELEVATION DETAIL NUMBER

ELEVATION ORIENTATION

SHEET NUMBER ON WHICH

ELEVATION OCCURS

ROOM AREA

WALL SECTION

OR BUILDING

SECTION

REFERENCE

ROOM NUMBER

SHEET NUMBER ON

WHICH SECTION OCCURS

SECTION ORIENTATION

SECTION DETAIL NUMBER

ROOM NAME

COLUMN

IDENTIFICATION

B

CALLOUT DETAIL

REFERENCE

A501

A1

COLUMN CENTERLINE

DRAWING ON WHICH

DETAIL OCCURS

DETAIL NUMBER

REVISION SYMBOLS

REVISION AREA

REVISION DELTA

SUBCATEGORY

SHEET NUMBER

ITEM

CATEGORY

DISCIPLINE:

L - Landscape

S - Structural

A - Architectural

P - Plumbing

E - Electrical

M - Mechanical (HVAC)

C - Civil

RIGID INSULATION

POROUS FILL

GYPSUM BOARD /

GROUT FILL

BATT INSULATION

STEEL

PLYWOOD

(OR GLULAM)

CONTINUOUS

ROUGH LUMBER

DISCONTINUOUS

ROUGH LUMBER

CONCRETE MASONRY UNITSFINISH LUMBER

CONCRETE

EARTH

PROJECT

NORTH ARROW

DRAWING INDEX

BEXISTING COLUMN

IDENTIFICATION

LIST OF ABBREVIATIONS

MISCELLANEOUS CHANNEL

MECHANICAL/ELECTRICAL/PLUMBING

LAMINATED VENEER LUMBER

COMPT COMPARTMENT

BW

BVL

BOTH WAYS

BEVELED

BM

BSL

BS

BOT

BRK

BUR

BRG PL

BRG

BSMT

BO

BD

BLDG

BLK(G)

BIT

BET

BEL

BENCH MARK

BUILDING SETBACK LINE

BUILT UP ROOFING

BOTH SIDES

BEARING PLATE

BOTTOM OF

BASEMENT

BRICK

BEARING

BOTTOM

BITUMINOUS

BLOCK(ING)

BUILDING

BOARD

BETWEEN

BELOW

CP

CT

CYD

CORR

CRS

CR

CSMT

CENTER POINT

CUBIC YARD

COURSE(S)

CORRUGATED

CERAMIC TILE

CHROMIUM (PLATED)

CASEMENT

ADDENDUMADD

A/V

AUTO

ASPH

ASB

ARCH

APROX

ANOD

AP

AHU

A/E

ADD'D

ANC

ALUM

ALT

ADJ

ADH

AFF

ANCHOR(AGE)

AUDIO VISUAL

ACCESS PANEL

APPROXIMATE

ARCHITECT(URAL)

ANODIZED

ASBESTOS

ASPHALT

AUTOMATIC

AIR HANDLING UNIT

ARCHITECT/ENGINEER

ADDITIONAL

ABOVE FINISHED FLOOR

ADJUSTABLE

ADHESIVE

ALTERNATE

ALUMINUM

AD

AB

A/C

ACT

ACPL

AC

ACC

ABV

ACOUSTICAL

ACOUSTICAL PLASTER

ACOUSTICAL TILE

AIR CONDITIONING

ANCHOR BOLT

AREA DRAIN

ABOVE

ACCESS

CI CAST IRON

CNTRSNK

CO

CONN

CONT

CONTR

CONST

CONC

COL

CNTR

CLOS

CK

CJ

CMU

CLS

CLR

CIR

CLC

CIP

CONNECTION

COUNTERSINK

CONTRACT(OR)

CONTINUOUS

CONSTRUCTION

CLEAN OUT

CENTER

CONCRETE

COLUMN

CONTROL JOINT

CAST-IN-PLACE

CONC MASONRY UNIT

CLEAR(ANCE)

CLOSET

CAULK

CEILING

CLOSURE

CIRCLE

CG

C/C

CAT

CFT

CHAM

CHT

CB

CAB

CORNER GUARD

CENTER TO CENTER

CUBIC FOOT

CEILING HEIGHT

CAST BASIN

CATEGORY

CHAMFER

CABINET

MANHOLEMH

INVERTINV

FRP FIBERGLASS REINFORCED

PLASTICEJ EXPANSION JOINT

GALVANIZED STEEL SHEET

EQUIP

EXT

EXP

EX

EST

ESC

EWC

ENGR

EQ

ENCL

EMER

ELEV

EL

EP

ELEC

EQUIPMENT

EXPANDED(EXPANSION)

ELECTRIC WATER COOLER

EXTERIOR

EXISTING

ESTIMATE

ESCALATOR

ELECTRICAL POWERBOARD

ENGINEER

EQUAL

ENCLOSE(URE)

EMERGENCY

ELEVATOR

ELEVATION

ELECTRICAL

GKT GASKET(ED)

GP

GYP

GWB

GYPBD

GLAM

GL

GSS

GYPSUM WALL BOARD

GYPSUM BOARD

GLUE LAMINATED

GALVANIZED PIPE

GYPSUM

GLASS

GA

GI

GEN'L

GD

GB

GC

GALV

FURN

FT

FUT

FUR

FS

FTG

FRT

GALVANIZED IRON

GENERAL CONTRACTOR

GALVANIZED

GAUGE

GENERAL

GRADE

GRAB BAR

FURNITURE/FURNISHINGS

FIRE-RETARDANT

FOOT

FUTURE

FURRING

FULL SIZE

FOOTING

JT

KIT

KO

JC

JB

JF

JST

IPS

JOINT

KITCHEN

KNOCKOUT

JANITOR CLOSET

JUNCTION BOX

JOINT FILLER

IRON PIPE SIZE

JOIST

MIR

MISC

MIN

MTD

MO

MM

MT

MASONRY OPENING

MIRROR

MISCELLANEOUS

MILLIMETER

MINIMUM

METAL THRESHOLD

MOUNTED

FIRE-RESISTANT COATING

FIRE EXTINGUISHER CABINET

FINISHED FLOOR ELEVATION

EXTERIOR INSULATION & FINISH

SYSTEM

DISP DISPENSER

EB

EIFS

E

EA

DWR

DR

DN

DWG

DRB

DS

DIV DR

DTL

DL

DP

EXPANSION BOLT

EAST

EACH

DRAWER

DIVISION DOOR

DAMP PROOFING

DOOR

DOWN

DRAWING

DRAIN BOARD

DOWN SPOUT

DETAIL

DEAD LOAD

DEPT

DBL

DF

DH

DIM

DIA

DEP

DEMO

DRINKING FOUNTAIN

DEMOLISH, DEMOLITION

DEPARTMENT

DOUBLE

DIMENSION

DOUBLE HUNG

DIAGONAL

DEPRESSED

FF FACTORY FINISH

FR

FND

FPL

FRC

FP

FOS

FOF

FOM

FOC

FLUOR

FH

FJT

FLR

FLEX

FLG

FFE

FIN

FGL

FRAME(D)(ING)

FOUNDATION

FLOOR PLATE

FACE OF STUDS

FACE OF FINISH

FACE OF MASONRY

FACE OF CONCRETE

FIREPROOF

FLUORESCENT

FIRE HYDRANT

FLUSH JOINT

FIBERGLASS

FLOOR

FLEXIBLE

FLASHING

FINISH(ED)

FBO

FCO

FEC

FE

FA

FAS

FD

FB

FURNISHED BY OTHERS

FLOOR CLEAN OUT

FIRE EXTINGUISHER

FIRE ALARM

FASTEN, FASTENER

FLOOR DRAIN

FACE BRICK

INSULATED BY CONTRACTOR

HEATING/VENTILATING/AIR

CONDITIONING

HP HIGH POINT

INCL

INT

IBC

INFO

ID

INSUL

HR

HWH

HRDW

HWD

HD HT

HTG

HT

HVAC

HOT

WATER

HEATER

INCLUDE(D)(ING)

INFORMATION

INSIDE DIAMETER

INSULATION

INTERIOR

HARDWOOD

HEAD HEIGHT

HOUR

HARDWARE

HEATING

HEIGHT

HM

HB

HOR

HBD

HJT

HDR

HD

HC

HOLLOW METAL

HORIZONTAL

HARDBOARD

HEAD JOINT

HEAVY DUTY

HOLLOW CORE

HOSE BIBB

HEADER

LUMP SUMLS

MED

MEMB

MECH

MAS

MAT'L

MAX

MEP

MTL

MFR

LVR

LVL

MC

M

LT

MATERIAL

MECHANICAL

MEDIUM

MEMBRANE

MAXIMUM

MANUFACTURER

METAL

MASONRY

LOUVER

METER

LIGHT

LAV

LAM

LBL

LAB

LF

LH

LB

LL

LAVATORY

LAMINATE

LINEAR FOOT

LEFT HAND

LABORATORY

LAG BOLT

LIVE LOAD

LABEL

WROUGHT IRON

VINYL ASBESTOS TILE

WELDED WIRE FABRIC

WALL TO WALL

UNDERWRITERS

LABORATORY

UNLESS NOTED OTHERWISE

VAPOR BARRIER

VINYL COMPOSITION TILE

WHEEL BUMPER

WATER REPELLENT

WATERPROOFING

WATER CLOSET

WHB

STANDARDSTD

ROOMRM

PRE CAST CONCRETEPCC

ROUGH OPENING

REVERSE(SIDE)

RIGHT OF WAY

RAIN WATER CONDUCTOR

POLYVINYL CHLORIDE

POUNDS PER CUBIC FOOT

POUNDS PER LINEAL FOOT

POUNDS PER SQUARE FOOT

POINT/PRESSURE TREATED

POUNDS PER SQUARE INCH

PROPERTY LINE/PLATE

PREFABRICATE(D)

PRE FINISHED

PLASTIC LAMINATE

PAIR/PROPOSAL REQUEST

PRELIMINARYPRELIM

PVC

PSF

PT

PSI

PRF

PTN

PVMT

PERFORMED

PARTITION

PAVEMENT

PLF

PLYWD

PREFAB

PNT

PR

POL

PLBG

PNL

PNTD

PLYWOOD

PAINT

POLISHED

PLUMBING

PANEL

PAINTED

PCF

PG

PL

PERIM

PH

PFN

PJ

PLAM

PLAS

PLATE GLASS

PERIMETER

PHASE

PANEL JOINT

PLASTER

RO

ROW

RVS

RWC

TOP OF MASONRY

TONGUE AND GROOVE

TOILET PARTITION

TOILET PAPER DISPENSER

THRES THRESHOLD

TR TRANSOM

TYPICAL

TELEVISION

TYP

TV

TOLERANCE

TOP OF

TOP OF STEEL

TOP OF WALL

TOILET

TOL

TO

TOM

TOS

TOW

TLT

TPTN

TPD

TOWEL BAR

TREAD

THICK(NESS)

TEMPORARY

TERRAZZO

TELEPHONE

TB

T

T&G

THK

TEMP

TER

TEL

SYSTEM

SYNTHETIC

SYMMETRY(ICAL)

SUSPENDED

STRUCTURAL

STORAGE

STEEL

SYS

SYN

SYM

SUS

STR

STOR

STL

WTW

WWF

WI

WSCT

WO

WM

WIN

WTH

WS

WR

WP

WAINSCOT

WITHOUT

WIRED MESH

WINDOW

WIDTH

WATER STOP

RUBBER BASE

REQUEST FOR INFO

ROOF HATCH

REFLECTED CEILING PLAN

REVISION(S),(D)

REFLECT(ED),(ING)

REFRIGERATOR

RAIN LEADER

REINFORCE(D),(ING)

QUARRY TILE

VERTICAL DATUM

NATIONAL GEODETIC

NOT APPLICABLE

NOT IN CONTRACT

OUTSIDE DIAMETER

NOT TO SCALE

OVERFLOW ROOF DRAIN

OPPOSITE HAND

PC

OV

OPP

ORD

OS

PRE CAST

OVERALL

OPPOSITE

OUTSIDE

OC

OFC

OH

OD

OPG

OH/OPH

ON CENTER

OFFICE

OVERHEAD

OPENING

NGVD

N

NA

NIC

NO

NOM

NTS

NORTH

NUMBER

NOMINAL

RADIUSRAD

RFI

RFH

RFG

REV

RES

RET

RH

RFL

RL

ROOFING

RESILIENT

RETURN

RIGHT HAND

REQ'D

RD

RB

RCP

REM

REF

REFR

REG

REINF

REQUIRED

ROOF DRAIN

REMOVE

REFERENCE

REGISTER

RA

R

QTR

QT

RETURN AIR

RISER

QUARTER

SLAB ON GRADE

STAINLESS STEEL

SPECIFICATION(S)

SHELVINGSH

STATION

SQUARE YARD

SQUARE INCH

SQUARE

SPECIAL

SPEAKER

SPACER

STA

SQ/YD

SQ/IN

SS

SQ

SPEC

SPL

SPK

SPCR

SEALER

STEEL JOIST

SHELVING

SOUND PROOF

SLEEVE

SIMILAR

SHEET

SHEATHING

SOG

SLR

SJ

SHELV

SP

SL

SIM

SHT

SHTH

SQUARE FOOT

SOUTH

STORM DRAIN

SOLID CORE

SHEET GLASS

SECTION

SCHEDULE

SAFETY GLASS

SF

S

SD

SC

SG

SECT

SCHED

SFGL

W/

WH

WB

WD

WG

W

WC

WITH

WALL HUNG

WOOD BASE

WOOD

WIRED GLASS

WEST

VAT

VEST

VB

VCT

VAR

VERT

VESTIBULE

VARNISH

VERTICAL

UNF

UR

UL

UNO

UC

UNFINISHED

URINAL

UNDERCUT

OPCI OWNER PROVIDED

CONTRACTOR INSTALLED

OPOI OWNER PROVIDED

OWNER INSTALLED

CPCI CONTRACTOR PROVIDED

CONTRACTOR INSTALLED

RECEP RECEPTIONIST

SECRETARYSECR

SECURITYSECU

AHJ AUTHORITY HAVING JURISDICTION

VOL VOLUME

FV FIELD VERIFIED

UNO

4" TYP

SYMBOL LEGEND

ROOM

NAMEROOM

IDENTIFICATION

A711

MULTIPLE

INTERIOR

ELEVATION

REFERENCE

A1

A3

A2A4

ELEVATION DETAIL NUMBER

ELEVATION ORIENTATION

SHEET NUMBER ON WHICH

ELEVATION OCCURS

FIRST FLOOR

100' - 0"

SPECIALITY

EQUIPMENT

IDENTIFICATION

EQUIPMENT TYPE

(REFER TO EQUIPMENT

SCHEDULE)A

02 4 8134 no.revision

G - General

ID - Interior Design

FS - Food Service

FP - Fire Protection

T - Technology

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

12" = 1'-0"

G001

GENERAL

INFORMATION

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL

REV. NO. SHEET NAME

G000 COVER SHEET

G001 GENERAL INFORMATION

G041 CLEARANCE / WALL TYPES / DETAILS

G101 LIFE SAFETY PLAN

G102 EXISTING PLAN - LEVEL 5

Grand total: 5

ARCHITECTURAL DEMOLITION

REV. NO. SHEET NAME

AD101 DEMOLITION PLANS

Grand total: 1

ARCHITECTURAL

REV. NO. SHEET NAME

A101 LOCATION PLAN- LEVEL 3

A102 LOCATION PLAN - LEVEL 5

A111 FLOOR PLANS LEVEL 5

A112 FFE AND FINISH FLOOR PLANS LEVEL 3

A113 FFE AND FINISH FLOOR PLANS LEVEL 5

A221 INTERIOR SECTIONS & ELEVATIONS

A601 DOOR SCHEDULE & DETAILS

Grand total: 7

MECHANICAL

REV. NO. SHEET NAME

M001 HVAC GENERAL NOTES

M101 RENOVATION PLANS -HVAC

MD101 DEMOLITION PLANS - HVAC

Grand total: 3

FIRE PROTECTION

REV. NO. SHEET NAME

FP101 RENOVATION PLANS - FIRE PROTECTION

Grand total: 1

ELECTRICAL

REV. NO. SHEET NAME

E001 ELECTRICAL GENERAL NOTES

E101 RENOVATION PLANS -ELECTRICAL

E102 RENOVATION PLANS -SYSTEMS

ED101 DEMOLITION PLANS - ELECTRICAL

ED102 DEMOLITION PLANS -SYSTEMS

Grand total: 5

DATE SUBMISSION/REVISION NO.

NOTE: ALL DIMENSIONS TO

CENTER LINE OF DEVICES.

SEE PLANS FOR SPECIFIC

LOCATIONS.

DOOR HARDWARE

AUDIBLE/VISIBLE

STROBE

LOCATION FOR WALL MOUNTED

DEVICE CLUSTER, WHICH MAY

INCLUDE ITEMS SUCH AS LIGHT

SWITCH, DIMMERS, EGRESS

BUTTON, CARD READER, (DEVICES

NO TALLER THAN 5") - SEE PLAN

FOR QUANTITY OF EACH CLUSTER

USE GANG-TYPE COVER PLATES

FOR MORE THAN ONE DEVICE OF

THE SAME TYPE

DOOR FRAME

FIRE EXTINGUISHER AND /OR

HOSE CABINET

1" MIN BETWEEN WALL

MOUNTED DEVICES OR

OUTLETS PLACED

BETWEEN 48" AFF AND

15" AFF

4" MIN

5"

THERMOSTAT LOCATION (DO

NOT LOCATE DIRECTLY ABOVE

DIMMERS )

NOTE:

X = 12" IF DOOR HAS BOTH A

CLOSER AND A LATCH

NOTE:

X = 36" MIN IF Y = 60";

X = 42" MIN IF Y = 54"

NOTE:

Y = 48" MIN OR

Y= 54" MIN IF DOOR HAS A

CLOSER

NOTE:

Y = 42" MIN OR

Y = 48" MIN IF DOOR HAS A

CLOSER AND LATCH

NOTE:

Y = 42"MIN OR

Y = 48" MIN IF DOOR HAS A

CLOSER

18"

X

X

Y

Y

24"

22"

Y

24"Y 48"

48"

WIDTH

/4

S3TYPE

FINISH AS

SCHEDULED

BASE AS SCHEDULED

AT "B" WALL HEIGHT

CONDITIONS,

EXTEND GYP BOARD

TO CEILING

GYP BD, TYP

FLOOR SLAB

MTL STUDS FRAMING @

16" OC, THICKNESS AS

NOTED BY MATERIAL

WIDTH NUMBER

DESIGNATION

CEILING AS SCHEDULED

UNDERSIDE OF

ROOF/ FLOOR DECK

AT WALL HEIGHT A

CONDITIONS

SECURELY ANCHOR

CHANNEL TO DECK

S L

IP

C O

N N

E C

T

IO

N

CONT LONG LEG

RUNNER

S3 3-5/8" MTL STUDS

TYPE DESCRIPTION REF DESIGN STC

MTL STUDS

BRACING AT 48"

OC SECURE TO

DECK ABOVE AT

WALL HEIGHT B

CONDITIONS

EXTEND GYP BOARD TO

DECK AT "A" WALL TYPE

AND HEIGHT CONDITIONS

GYP BD EACH SIDE

REFER TO GENERAL

PARTITION TYPE NOTES

FOR MOR INFORMATION

CAULK JOINTS AT

BASE OF GYPSUM

BOARD

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

G041

CLEARANCE / WALL

TYPES / DETAILS

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - WALL TYPES

A GYPSUM BOARD TO BE INSTALLED A MINIMUM OF 1/2" ABOVE THE FLOOR SLAB.

GENERAL NOTE: THE INFORMATION ON THIS SHEET IS

FOR REFERENCE ONLY. THE GENERAL CONTRACTOR

SHALL COMPLY AND COORDINATE WITH THE LATEST

FLORIDA BUILDING CODE ACCESSIBILITY GUIDELINES.

SCALE: 1/2" = 1'-0"G041

A4 ADA CLEARANCE

SCALE: 1/4" = 1'-0"G041

A7 ADA DOOR SWING

SCALE: 1" = 1'-0"G041

E7 WALL TYPES

4' -0

4'-0"

4'-6"

5' -0

1'-2"

1'-8"

3'-10"

COMMISSIONER

DISTRICT 2 OFFICE

COMMISSIONER

DISTRICT 5 OFFICE

COMMISSIONER

DISTRICT 3 OFFICE

COMMISSIONER

DISTRICT 4 OFFICE

COMMISSIONER

DISTRICT 6 OFFICE

DISTRICT 1

OFFICE

DISTRICT 1

SUPPORT

COMMISSIONER

DISTRICT 6 SUPPORT

COMMISSIONER

DISTRICT 4 SUPPORT

COMMISSIONER

DISTRICT 3 594

COMMISSIONER

DISTRICT 5

COMMISSIONER

DISTRICT 2

BREAK

ROOM

OPEN TO

BELOW

ELEVATOR

LOBBY

MEN

WOMEN 530

WOMEN

MEN

SENIOR

STAFF

LEGISLATIVE

DIRECTOR

CHIEF OF

STAFF

COPY/FAX

SCHEDULER

AID

SECURITY

AID

BREAK

ROOM

COUNTY

ADMINISTRATOR

STAFF

ANALYST

STAFF

ANALYST

STAFF

ANALYST

STAFF

ANALYST

PALM

CONFERENCE

COPY/WORK

HVAC

OFFICE

OFFICE

VACANT

OFFICE

COPY/FAX

OPEN TO

BELOW

CHAIRMAN'S

OFFICE

CONFERENCE

ROOM

SENIOR

STAFF

SENIOR

STAFF

SENIOR

STAFF

COMMUNICATIONS

OFFICE

COPY/FAX

CONFERENCE

ROOM

TOILET

CLOSET

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

VESTIBULE

VESTIBULE

VESTIBULE

CORRIDOR

C O R R

ID

O R

WORKING

AREA

WORKING

AREA

CORRIDOR

VESTIBULE

VESTIBULE

BRIDGE

RECEPTION

WAITING

AREA

WAITING

AREA

RECEPTION

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE

CORRIDOR

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

STAIR

VESTIBULE

MECHANICAL

ELECTRICAL

CLOSET

CLOSET

CLOSET

CLOSET

TEL.

STAIR

TOILET

TOILET

COMMISSIONER

DISTRICT 2

C O M M

IS

S

IO

N E R

D

IS

T R

IC

T

C O M M

IS

S

IO

N E R

D

IS

T R

IC

T

TRAVEL DISTANCE TO AN EXIT

LIFE SAFETY LEGEND

EXIT SIGN

EXISTING AREA TO REMAIN AS IS.

NOT IN SCOPE OF WORK

BUILDING INFORMATION

1. OCCUPANCY CLASSIFICATION: EXISTING: GROUP B / BUSINESS OCCUPANCY

PROVIDEDREQUIRED

MEANS OF EGRESS

1. MAXIMUM TRAVEL DISTANCE TO

AN EXIT

SEE LIFE

SAFETY PLAN

CHAPTER 10 - FBC 2023

(PER TABLE1017.2 FBC 2023 - EXIT ACCESS

TRAVEL DISTANCE)

2. MAXIMUM COMMON PATH OF

TRAVEL

(PER TABLE 1006.2.1 FBC 2023 - COMMON

PATH OF EGRESS TRAVEL)

SEE LIFE

SAFETY PLAN

SEE LIFE

SAFETY PLAN50 FEET

3. MAXIMUN DEAD END CORRIDOR

(PER SECTION 1020.4 DEAD ENDS)

4. FORCE TO OPEN, APPLIED AT THE LATCH STILE (FBC 1010.1.3/NFPA 101_ 7.2.1.4.5)

4.1. LESS THAN OR EQUAL TO 15 LBF TO OPERATE THE LATCH

4.2. LESS THAN OR EQUAL TO 30 LBF TO SET THE DOOR IN MOTION

4.3. LESS THAN OR EQUAL TO 15 LBF TO FULLY OPEN DOOR TO MINIMUN

REQUIRED WITDH

4.4. LESS THAN OR EQUAL TO 5 LBF FOR INTERIOR SIDE-HINGED OR PIVOTED

SWINGING DOORS WITHOUT CLOSERS

5. EXIT SIGNS: EXIT SIGN PLACEMENT SHALL BE SUCH THAT NO POINT IN A EXIT

ACCESS CORRIDOR OR EXIT PASSAGEWAY IS MORE THAN 100 FT OR THE LISTED

VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST

VISIBLE EXIT SIGN (FBC 1013.1 / NFPA 101_7.10.1.5.2)

APPLICABLE CODES

1. FLORIDA BUILDING CODE (FBC) 2023 EIGHTH EDITION

2. FLORIDA ACCESSIBILITY CODE 2023 EIGHTH EDITION

3. FLORIDA FIRE PREVENTION CODE (FFPC) 2021 EIGHTH EDITION

OTHER APPLICABLE CODE CRITERIA, BUT NOT LIMITED TO THE FOLLOWING:

1. NFPA 1, "UNIFORM FIRE CODE," 2021 ED. AS MODIFIED BY FFPC

2. NFPA 10, "STANDARD FOR PORTABLE FIRE EXTINGUISHERS," 2022 EDITION

3. NFPA 13, "STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS," 2022 EDITION

4. NFPA 30, "FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE," 2021 EDITION

(REF. SECTION 9.5.4)

5. NFPA 45, "STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS," 2019

EDITION (REF. SECTION 4.2.2.2, 5.1.2 & 9.1.1)

6. NFPA 70, "NATIONAL ELECTRICAL CODE," 2020 EDITION

7. NFPA 72, "NATIONAL FIRE ALARM CODE," 2022 EDITION

8. NFPA 80, "STANDARD FOR FIRE DOORS AND FIRE WINDOWS," 2022 EDITION

9. NFPA 101, " LIFE SAFETY CODE," (LSC) 2021 ED., AS MODIFIED BY THE FFPC

10. NFPA 110, " STANDARD ON EMERGENCY AND STANDBY POWER SYSTEMS, 2022 EDITION.

11. CLASSIFICATION OF WORK: ALTERATION LEVEL 2 PER FBC SEVENTH EDITION 2020

EXISTING BUILDING CHAPTER 5 SECTION 504.1

3. EXISTING BUILDING AREA (GROUND AREA FOOTPRINT) 33.600 SF

6. OFFICE RECONFIGURATION - PROJECT AREA 1,586 SF

4. EXISTING NUMBER OF STORIES 5 STORIES

(B) = 300 FT

(B) = 100 FT

SCOPE OF WORK

THIS IS A LEVEL 2 ALTERATION OF THE EXISTING ORANGE COUNTY GOVERNMENT

ADMINISTRATION BUILDING. THERE WILL BE MINOR RECONFIGURATION OF SPACES

THAT INCLUDES RECONFIGURATION OF WALLS, HVAC DISTRIBUTION, LIGHTING AND

ELECTRICAL DEVICES.

5. SPRINKLERED FULLY SPRINKLERED

2. OCCUPANT LOAD: NO CHANGE

PLUMBING

EXISTING OCCUPANT LOAD TO REMAIN THE SAME. EXISTING PLUMBING FIXTURES TO

REMAIN. RESTROOMS ARE NOT IN SCOPE OF WORK.

GENERAL NOTES

1. EXISTING LIFE SAFETY ITEMS SUCH AS EXIT SIGNS AND FIRE EXTINGUISHERS

TO REMAIN U.N.O.

2. EXSITNG FIRE RESISTANT RATED WALLS SUCH AS FOR SHAFTS, EXIT STAIRS,

AND ELEVATORS TO REMAIN AND BE MAINTAINED.

3. ALL LIFE SAFETY SYSTEMS INCLUDING FIRE SPRINKLER, STANDPIPIE, FIRE

ALARM AND SMOKE CONTROL SYSTEMS SHALL BE MAINTAINED AND KEPT

OPERATIONAL AT ALL TIMES DURING CONSTRUCTION.

DISTRICT 07 SUITE

689 SF

DISTRICT 08 SUITE

619 SF

COMMISSIONER

OFFICE

WORK

ROOM

RECEPTION

COMMISSIONER

OFFICE

RECEPTION

WORK

ROOM

EXISTING

COORIDOR

TRAVEL DISTANCE: 139'

TRAVEL DISTANCE: 112'

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

G101

LIFE SAFETY PLAN

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

SCALE: 3/32" = 1'-0"G101

A2 LIFE SAFETY PLAN - LEVEL 5

4'-0"

4'-6"

5' -0

1'-2"

1'-8"

3'-10"

COMMISSIONER

DISTRICT 2 OFFICE

COMMISSIONER

DISTRICT 5 OFFICE

COMMISSIONER

DISTRICT 3 OFFICE

COMMISSIONER

DISTRICT 4 OFFICE

COMMISSIONER

DISTRICT 6 OFFICE

DISTRICT 1

OFFICE

DISTRICT 1

SUPPORT

COMMISSIONER

DISTRICT 6 SUPPORT

COMMISSIONER

DISTRICT 4 SUPPORT

COMMISSIONER

DISTRICT 3 594

COMMISSIONER

DISTRICT 5

COMMISSIONER

DISTRICT 2

BREAK

ROOM

OPEN TO

BELOW

ELEVATOR

LOBBY

MEN

WOMEN 530

WOMEN

MEN

SENIOR

STAFF

LEGISLATIVE

DIRECTOR

CHIEF OF

STAFF

COPY/FAX

SCHEDULER

AID

SECURITY

AID

BREAK

ROOM

COUNTY

ADMINISTRATOR

STAFF

ANALYST

STAFF

ANALYST

STAFF

ANALYST

STAFF

ANALYST

PALM

CONFERENCE

COPY/WORK

HVAC

OFFICE

OFFICE

OFFICE

VACANT

OFFICE

CONFERENCE

ROOM

COPY/FAX

OPEN TO

BELOW

CHAIRMAN'S

OFFICE

CONFERENCE

ROOM

CONFERENCE

ROOM

SENIOR

STAFF

SENIOR

STAFF

SENIOR

STAFF

COMMUNICATIONS

OFFICE

COPY/FAX

CONFERENCE

ROOM

TOILET

CLOSET

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

VESTIBULE

VESTIBULE

VESTIBULE

CORRIDOR

C O R R

ID

O R

WORKING

AREA

WORKING

AREA

CORRIDOR

VESTIBULE

VESTIBULE

BRIDGE

RECEPTION

WAITING

AREA

WAITING

AREA

RECEPTION

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE

CORRIDOR

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

STAIR

VESTIBULE

MECHANICAL

ELECTRICAL

CLOSET

CLOSET

CLOSET

CLOSET

TEL.

STAIR

TOILET

TOILET

COMMISSIONER

DISTRICT 2

C O M M

IS

S

IO

N E R

D

IS

T R

IC

T

C O M M

IS

S

IO

N E R

D

IS

T R

IC

T

Oak Conference

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

3/32" = 1'-0"

G102

EXISTING PLAN -

LEVEL 5

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - FLOOR PLAN

A THESE DRAWINGS HAVE BEEN DEVELOPED FROM OBSERVED FIELD CONDITIONS

AND MAY NOT REFLECT ALL HIDDEN CONDITIONS. THE CONTRACTOR SHALL VISIT

THE PROJECT SITE AND SHALL VERIFY THESE DRAWINGS WITH THE EXISTING

FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING

OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS.

B IT IS THE INTENT OF THIS FACILITY TO REMAIN OPERATIONAL FOR THE DURATION

OF THIS PROJECT. CONTRACTOR SHALL ENSURE SAFETY OF ALL OCCUPANTS.

ITEMS WHICH MAY CREATE DUST, NOISE, OR CIRCULATION PROBLEMS SHALL BE

COORDINATED WITH OWNER PRIOR TO START OF WORK.

C CONTRACTOR SHALL PROTECT ALL ITEMS INTENDED TO REMAIN IN PLACE

DURING CONSTRUCTION FROM DAMAGE DURING DEMOLITION WORK AND SHALL

BEAR ALL COSTS OF REPAIRING OR REPLACING EXISTING ITEMS DAMAGED

DURING CONSTRUCTION.

D ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS

ASSOCIATED WITH DEMOLITION AND NEW WORK. FOR ADDITIONAL GENERAL

NOTES, LEGENDS, AND SCHEDULES REFER TO SHEET G001.

E ALL MATERIAL STORED ON SITE SHALL BE PROPERLY PROTECTED FROM INJURY

OR DETERIORATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS

INCURRED TO CLEAN THE STORED MATERIAL TO THE SATISFACTION OF THE

OWNER AND DESIGNER.

F WHERE CONFLICT EXISTS AMONG THE VARIOUS PARTS OF THE CONTRACT

DOCUMENTS, DRAWINGS, GENERAL NOTES, AND SPECIFICATIONS, THE

STRICTEST REQUIREMENTS SHALL GOVERN.

G ARCHITECTUAL AND ENGINEERS DRAWINGS, AS PART OF THE CONTRACT

DOCUMENTS, INDICATE SUFFICIENT INFORMATION TO CONVEY DESIGN INTENT. IF

ERRORS, INCONSISTENCIES, OR OMISSIONS ARE DISCOVERED, PROMPTLY

NOTIFY THE ARCHITECT AND ENGINEERS IN WRITING.

SCALE: 3/32" = 1'-0"G102

A1 EXISTING FLOOR PLAN - LEVEL 5

4'-0"

4'-6"

5' -0

1'-2"

1'-8"

3'-10"

COMMISSIONER

DISTRICT 2 OFFICE

COMMISSIONER

DISTRICT 5 OFFICE

COMMISSIONER

DISTRICT 3 OFFICE

COMMISSIONER

DISTRICT 4 OFFICE

COMMISSIONER

DISTRICT 6 OFFICE

DISTRICT 1

OFFICE

DISTRICT 1

SUPPORT

COMMISSIONER

DISTRICT 6 SUPPORT

COMMISSIONER

DISTRICT 4 SUPPORT

COMMISSIONER

DISTRICT 3 594

COMMISSIONER

DISTRICT 5

COMMISSIONER

DISTRICT 2

BREAK

ROOM

OPEN TO

BELOW

ELEVATOR

LOBBY

MEN

WOMEN 530

WOMEN

MEN

SENIOR

STAFF

LEGISLATIVE

DIRECTOR

CHIEF OF

STAFF

COPY/FAX

SCHEDULER

AID

SECURITY

AID

BREAK

ROOM

COUNTY

ADMINISTRATOR

STAFF

ANALYST

STAFF

ANALYST

STAFF

ANALYST

STAFF

ANALYST

PALM

CONFERENCE

COPY/WORK

HVAC

OFFICE

OFFICE

VACANT

OFFICE

COPY/FAX

OPEN TO

BELOW

CHAIRMAN'S

OFFICE

CONFERENCE

ROOM

SENIOR

STAFF

SENIOR

STAFF

SENIOR

STAFF

COMMUNICATIONS

OFFICE

COPY/FAX

CONFERENCE

ROOM

TOILET

CLOSET

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

WORKING

AREA

VESTIBULE

VESTIBULE

VESTIBULE

CORRIDOR

C O R R

ID

O R

WORKING

AREA

WORKING

AREA

CORRIDOR

VESTIBULE

VESTIBULE

BRIDGE

RECEPTION

WAITING

AREA

WAITING

AREA

RECEPTION

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE

CORRIDOR

KITCHEN

CLOSET

CLOSET

CLOSET

CLOSET

STAIR

VESTIBULE

MECHANICAL

ELECTRICAL

CLOSET

CLOSET

CLOSET

CLOSET

TEL.

STAIR

TOILET

TOILET

COMMISSIONER

DISTRICT 2

C O M M

IS

S

IO

N E R

D

IS

T R

IC

T

C O M M

IS

S

IO

N E R

D

IS

T R

IC

T

DISTRICT 07 SUITE

689 SF

DISTRICT 08 SUITE

619 SF

COMMISSIONER

OFFICE

WORK

ROOM

RECEPTION

COMMISSIONER

OFFICE

RECEPTION

WORK

ROOM

EXISTING

COORIDOR

A113

A1

A113

A6

DISTRICT 03 SUITE

SYSTEMS WORK ONLY

SEE SHEET E100

DISTRICT 05 SUITE

SYSTEMS WORK ONLY

SEE SHEET E100

DISTRICT 02 SUITE

SYSTEMS WORK ONLY

SEE SHEET E100

DISTRICT 01 SUITE

SYSTEMS WORK ONLY

SEE SHEET E100

DISTRICT 04 SUITE

SYSTEMS WORK ONLY

SEE SHEET E100

DISTRICT 05 SUITE

SYSTEMS WORK ONLY

SEE SHEET E100

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

3/32" = 1'-0"

A102

LOCATION PLAN -

LEVEL 5

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - FLOOR PLAN

A THESE DRAWINGS HAVE BEEN DEVELOPED FROM OBSERVED FIELD CONDITIONS

AND MAY NOT REFLECT ALL HIDDEN CONDITIONS. THE CONTRACTOR SHALL VISIT

THE PROJECT SITE AND SHALL VERIFY THESE DRAWINGS WITH THE EXISTING

FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING

OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS.

B IT IS THE INTENT OF THIS FACILITY TO REMAIN OPERATIONAL FOR THE DURATION

OF THIS PROJECT. CONTRACTOR SHALL ENSURE SAFETY OF ALL OCCUPANTS.

ITEMS WHICH MAY CREATE DUST, NOISE, OR CIRCULATION PROBLEMS SHALL BE

COORDINATED WITH OWNER PRIOR TO START OF WORK.

C CONTRACTOR SHALL PROTECT ALL ITEMS INTENDED TO REMAIN IN PLACE

DURING CONSTRUCTION FROM DAMAGE DURING DEMOLITION WORK AND SHALL

BEAR ALL COSTS OF REPAIRING OR REPLACING EXISTING ITEMS DAMAGED

DURING CONSTRUCTION.

D ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS

ASSOCIATED WITH DEMOLITION AND NEW WORK. FOR ADDITIONAL GENERAL

NOTES, LEGENDS, AND SCHEDULES REFER TO SHEET G001.

E ALL MATERIAL STORED ON SITE SHALL BE PROPERLY PROTECTED FROM INJURY

OR DETERIORATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS

INCURRED TO CLEAN THE STORED MATERIAL TO THE SATISFACTION OF THE

OWNER AND DESIGNER.

F WHERE CONFLICT EXISTS AMONG THE VARIOUS PARTS OF THE CONTRACT

DOCUMENTS, DRAWINGS, GENERAL NOTES, AND SPECIFICATIONS, THE

STRICTEST REQUIREMENTS SHALL GOVERN.

G ARCHITECTUAL AND ENGINEERS DRAWINGS, AS PART OF THE CONTRACT

DOCUMENTS, INDICATE SUFFICIENT INFORMATION TO CONVEY DESIGN INTENT. IF

ERRORS, INCONSISTENCIES, OR OMISSIONS ARE DISCOVERED, PROMPTLY

NOTIFY THE ARCHITECT AND ENGINEERS IN WRITING.

SCALE: 3/32" = 1'-0"A102

A2 NEW WORK LOCATION PLAN - LEVEL 5

DEMOLITION PLAN LEGEND

EXISTING WALL TO REMAIN

PROTECT FROM DAMAGE

EXISTING WALL TO BE REMOVED

EXISTING DOOR TO REMAIN,

PROTECT FROM DAMAGE

EXISTING DOOR AND/OR FRAME

TO BE REMOVED

D07

D07

D09

D16

D17

D11D11

D07

D08

D11

D19

D01

D06

D15

D14

D13

D09

D18D18

D10D10

A2

A221

D18

D03

D01

D02

D01

D04

D10

D09 D11

D11

D09

D12D12

D12D12

D13

DEMOLITION RCP LEGEND

EXISTING WALL

EXISTING SUSPENDED CEILING AND GRID TO

BE REMOVED IN ITS ENTIRETY

EXISTING SPRINKLER HEAD TO BE REMOVED

EXISTING LIGHTING FIXTURE TO BE REMOVED

EXISTING LIGHTING FIXTURE TO BE REMOVED

EXISTING DIFFUSER TO BE REMOVED

NOT IN SCOPE OF WORK

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

AD101

DEMOLITION PLANS

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - DEMOLITION

A VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF WORK. THE GENERAL

CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION AND

COORDINATION OF ALL EXISTING CONDITIONS WITH CONTRACT DESIGN

DOCUMENTS. CONTRACTOR SHALL NOTIFY OWNER AND ARCHITECT IN WRITING

OF ANY DISCREPANCIES PRIOR TO THE START OF DEMOLITION WORK.

B GENERAL CONTRACTOR SHALL COORDINATE THE DEMOLITION WORK

DESCRIBED IN THE DEMOLITION DRAWINGS OF EACH DISCIPLINE WITHIN THE

CONTRACT DOCUMENTS.

C PRIOR TO START OF DEMOLITION, THE CONTRACTOR SHALL CREATE A

CONSTRUCTION WORK PLAN FOR THE AREA OF WORK IN THE PRESENCE OF THE

OWNER, TO IDENTIFY EXISTING ITEMS TO REMAIN, TO BE SALVAGED, TO BE

REMOVED/REINSTALLED DURING CONSTRUCTION, AND TO IDENTIFY DAMAGED

ITEMS INDICATED TO REMAIN. WORK PLAN MUST BE ACCEPTED BY OWNER &

ARCHITECT.

D WHERE ITEMS ARE SCHEDULED TO REMAIN DURING CONSTRUCTION, GENERAL

CONTRACTOR MUST PROTECT THOSE ITEMS FROM DAMAGE. WHERE ITEMS ARE

SCHEDULED TO BE REMOVED AND REINSTALLED, THE GENERAL CONTRACTOR IS

RESPONSIBLE TO PROTECT AND STORE THOSE ITEMS DURING CONSTRUCTION.

E CONTRACTOR SHALL VERIFY ALL UTILITIES SHOWN ON CONTRACT DOCUMENTS

PRIOR TO DEMOLITION, EXCAVATION, OR CUTTING INTO ANY WALL OR SLAB.

NOTIFY OWNER AND ARCHITECT AND LOCATE ALL DISCOVERED UTILITIES OR

UTILITIES NOT IDENTIFIED ON THE CONSTRUCTION DOCUMENTS . GENERAL

CONTRACTOR MUST COORDINATE REROUTING OF EXISTING UTILITIES SO THAT

THERE ARE NO SERVICE INTERUPTIONS FOR THE OWNER.

F INTERRUPTION OF ANY EXISTING SERVICES SHALL BE COORDINATED BY THE

CONTRACTOR WITH THE UTILITY COMPANY, ARCHITECT, AND OWNER AS

NECESSARY, WITH A WRITTEN NOTICE AT LEAST ONE MONTH IN ADVANCE OF

ANTICIPATED INTERRUPTION. A SCHEDULE FOR THESE OUTAGES SHALL BE

DEVELOPED AND AGREED UPON BETWEEN PARTIES MENTIONED. GENERAL

CONTRACTOR TO COORDINATE WITH THE UTILITY PROVIDER TO ADHERE TO

THEIR REQUIREMENTS FOR SERVICE INTERRUPTION.

G OWNER SHALL NOT EXPERIENCE ANY UNSCHEDULED UTILITY DISRUPTIONS

CAUSED BY DEMOLITION OR CONSTRUCTION. GENERAL CONTRACTOR TO

FURNISH AND INSTALL ALL EQUIPMENT AND LABOR REQUIRED TO MAINTAIN

UTILITY SERVICE CONTINUITY FOR THE OWNER UNLESS OTHERWISE SCHEDULED

AND APPROVED BY THE OWNER AS A UTILITY INTERRUPTION.

H WHERE PARTITIONS ARE NOTED TO BE REMOVED, REMOVE PARTITION IN ITS

ENTIRETY, INCLUDING STUD BRACING, TO THE BOTTOM OF STRUCTURE, UNO.

J THIS FACILITY SHALL REMAIN OPERATIONAL FOR THE DURATION OF THIS

PROJECT. ENSURE SAFETY OF ALL OCCUPANTS. DEMOLITION OF ITEMS THAT

MAY CREATE DUST, NOISE, INTERRUPTION OF UTILITY SERVICES, AND

PEDESTRIAN CIRCULATION SHALL BE COORDINATED WITH OWNER PRIOR TO

START OF WORK.

K WHEN CUTTING INTO EXISTING WALLS, SLAB, CONTRACTOR SHALL NOT DAMAGE

THE STRUCTURAL INTEGRITY OF THESE AREAS. CONTRACTOR SHALL

DOCUMENT ALL MODIFICATIONS TO STRUCTURE AND/OR REBAR. CONTRACTOR

SHALL BE RESPONSIBLE FOR REPLACING, RESTORING AND MAINTAINING

STRUCTURAL PERFORMANCE WHERE THE STRUCTURAL SYSTEM HAS BEEN

COMPROMISED.

L REMOVAL OF ANY WALLS THAT PENETRATE THE SLAB REQUIRES THE GC TO

REMOVE THE WALL PAST THE UNDERSIDE OF THE SLAB. THE GC SHALL REPAIR

THE SLAB AND LEVEL THE FLOORS ON BOTH SIDES OF THE WALL SUCH THAT

THEIR ELEVATIONS ARE THE SAME AND ADHERE TO SPECIFIED FLATNESS

REQUIREMENTS.

M WHERE SURFACE MOUNTED ITEMS ARE REMOVED FROM WALLS: PATCH /REPAIR

WALLS AS REQUIRED TO MATCH EXISTING ADJACENT FINISHES.

N EXISTING SIGNAGE: REMOVE ALL EXISTING ROOM SIGNAGE THAT WILL BE NO

LONGER VALID AFTER COMPLETION OF CONSTRUCTION. THIS INCLUDES

DEPARMENT SIGNAGE, ROOM NAMES, ROOM NUMBERS, ETC.

P PATCH AND REPAIR SURFACE WHERE SIGNAGE WAS REMOVED. TURN OVER

SIGNAGE TO OWNER FOR REUSE OR DISPOSAL.

DEMOLITION KEYNOTE LEGEND

D01 EXISTING DOOR AND FRAME TO BE REMOVED, INFILL OPENING

D02 EXISTING WALL TO BE REMOVED IN ITS ENTIRETY

D03 SALVAGE CUBICALE AND RETURN TO OWNER

D04 CREATE OPENING FOR NEW DOOR

D06 EXISTING DOOR TO BE REMOVED AND STORED FOR REUSE IF POSSIBLE,

RELOCATE OPENING IN WALL PER NEW DOOR LOCATION

D07 EXISTING ACOUSTICAL CEILING TILES SHALL BE REMOVED IN THEIR ENTIRETY.

ALL LIGHT FIXTURES, DIFFUSERS, AND FIRE PROTECTION EQUIPMENT SHALL

BE REMOVED. 1'x4' LED LIGHTING FIXTURES TO BE REUSED

D08 EXISTING COFFER CEILING TO BE REMOVED

D09 EXISTING GLAZING TO REMAIN, PROTECT FROM DAMAGE DURING

CONSTRUCTION

D10 EXISTING WALLS TO REMAIN. PROTECT FROM DAMAGE DURING

CONSTRUCTION. REPAIR ANY DAMAGED AREAS AS NEEDED AND PREPARE

SURFACES FOR NEW FINISHES

D11 EXISTING COLUMNS TO REMAIN

D12 EXISTING CARPET TILE FLOORING TO BE REMOVED. PREP FLOORS TO

RECEIVE NEW CARPET

D13 EXISTING MONITOR TO BE REMOVED AND RETURNED TO OWNER

D14 WHITEBOARD CABINET TO BE REMOVED AND RETURN TO OWNER

D15 MILLWORK TO BE DEMOLISHED AND DISPOSED OF

D16 REMOVE PORTION OF CEILING AS INDICATED, INCLUDING ALL LIGHT FIXTURES,

DIFFUSERS, AND ACCESSORIES. PATCH AND REPAIR AS REQUIRED

D17 EXISTING CEILING TO REMAIN, PRODUCT FROM DAMAGE DURING

CONSTRUCTION

D18 DEMOLISH EXISTING GYPSUM BOARD ON THE INSIDE FACE OF THE WALL ONLY

D19 EXISTING GYPSUM BOARD CEILING, ALONG WITH ALL LIGHTING AND OTHER

DEVICES TO BE DEMOLISHED

SCALE: 1/4" = 1'-0"AD101

E1 DEMO RCP - DISTRICT 7

SCALE: 1/4" = 1'-0"AD101

E6 DEMO RCP - DISTRICT 8

SCALE: 1/4" = 1'-0"AD101

A6 DEMO FLOOR PLAN - DISTRICT 8

SCALE: 1/4" = 1'-0"AD101

A1 DEMO FLOOR PLAN - DISTRICT 7

WAP

F

F

F

WAP

F

F

F

F F

PLAN LEGEND

EXISTING WALL TO REMAIN

EXISTING DOOR TO REMAIN

METAL STUD PARTION

SEE PARTITION TYPES

METAL STUD PARTION WITH GLAZED TOP PANEL

NEW DOOR, SEE DOOR SCHEDULE

DOOR NUMBER

SEE DOOR AND WINDOW SCHEDULE SHEET

PARTITION TYPE INDICATOR

SEE WALL TYPES / DETAILS SHEET

OUTSIDE SCOPE OF WORK

CARD READER

XX-XX

XX-XX

1A

CR

RECEPTION

COMMISSIONER

OFFICE

WORK

ROOM

S3 B

S3 A

CR

EXISTING

WORKING

AREA

EXISTING

COORIDOR

S3 A

A221

E4

A5

A221

Sim

S3 A

ALIGN

5' - 2"

A L

IG

N

COMMISSIONER

OFFICE

RECEPTION

WORK

ROOM

S3 A

EXISTING BREAK ROOM

S3 A

S3 A

A221E7

A5

A221

A7

A221

A7

A221

Sim

C R

A2

A221

4' - 7" 4' - 8"

A2

A221

Sim

S3 A

A6012

A 9' - 0"

A 9' - 0"

A 9' - 0"

222222

A2

A221

A 9' - 0"

A 9' - 0"

A 9' - 0"

222222

REFLECTED CEILING LEGEND

1'x4' RECESSED DIRECT / INDIRECT LED TROFFER

HVAC DIFFUSER

HVAC RETURN AIR

FIRE SPRINKLER

CEILING MOUNTED HORN STROBE LIGHT

EXISTING ACOUSTICAL CEILING

CEILING MOUNTED STROBE LIGHT

WIRELESS ACESS POINT

LEGEND - CEILING TYPES

A ACOUSTICAL CEILING TILES

CEILING HEIGHT

CEILING TYPE

X X' - XX"

B GYPSUM BOARD

F

WAP

F

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

A111

FLOOR PLANS LEVEL

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - FLOOR PLAN

A THESE DRAWINGS HAVE BEEN DEVELOPED FROM OBSERVED FIELD CONDITIONS

AND MAY NOT REFLECT ALL HIDDEN CONDITIONS. THE CONTRACTOR SHALL VISIT

THE PROJECT SITE AND SHALL VERIFY THESE DRAWINGS WITH THE EXISTING

FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING

OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS.

B IT IS THE INTENT OF THIS FACILITY TO REMAIN OPERATIONAL FOR THE DURATION

OF THIS PROJECT. CONTRACTOR SHALL ENSURE SAFETY OF ALL OCCUPANTS.

ITEMS WHICH MAY CREATE DUST, NOISE, OR CIRCULATION PROBLEMS SHALL BE

COORDINATED WITH OWNER PRIOR TO START OF WORK.

C CONTRACTOR SHALL PROTECT ALL ITEMS INTENDED TO REMAIN IN PLACE

DURING CONSTRUCTION FROM DAMAGE DURING DEMOLITION WORK AND SHALL

BEAR ALL COSTS OF REPAIRING OR REPLACING EXISTING ITEMS DAMAGED

DURING CONSTRUCTION.

D ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS

ASSOCIATED WITH DEMOLITION AND NEW WORK. FOR ADDITIONAL GENERAL

NOTES, LEGENDS, AND SCHEDULES REFER TO SHEET G001.

E ALL MATERIAL STORED ON SITE SHALL BE PROPERLY PROTECTED FROM INJURY

OR DETERIORATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS

INCURRED TO CLEAN THE STORED MATERIAL TO THE SATISFACTION OF THE

OWNER AND DESIGNER.

F WHERE CONFLICT EXISTS AMONG THE VARIOUS PARTS OF THE CONTRACT

DOCUMENTS, DRAWINGS, GENERAL NOTES, AND SPECIFICATIONS, THE

STRICTEST REQUIREMENTS SHALL GOVERN.

G ARCHITECTUAL AND ENGINEERS DRAWINGS, AS PART OF THE CONTRACT

DOCUMENTS, INDICATE SUFFICIENT INFORMATION TO CONVEY DESIGN INTENT. IF

ERRORS, INCONSISTENCIES, OR OMISSIONS ARE DISCOVERED, PROMPTLY

NOTIFY THE ARCHITECT AND ENGINEERS IN WRITING.

KEYNOTE LEGEND

01 METAL STUD WALL WITH GLAZED TOP PANEL

02 VERIFY THAT THE EXISTING STUDS EXTEND CONTINUOUSLY FROM THE FLOOR

TO THE UNDERSIDE OF THE DECK WITHOUT ANY GAPS. INSTALL BATT

INSULATION IN THE CAVITY FULL HEIGHT TO THE DECK. AFTER INSULATION IS

INSTALLED, APPLY TWO NEW LAYERS OF GYPSUM BOARD FULL HEIGHT TO

THE DECK

03 EXISTING WALL TO REMAIN, PROTECT FROM DAMAGE DURING CONSTRUCTION

05 INFILL WALL AT DOOR OPENING. MATCH ADJACENT WALL CONDITIONS

22 NEW ACOUSTICAL CEILING

SCALE: 1/4" = 1'-0"A111

A1 FLOOR PLAN - DISTRICT 7

SCALE: 1/4" = 1'-0"A111

A6 ENLARGED FLOOR PLAN - DISTRICT 8

SCALE: 1/4" = 1'-0"A111

E6 RCP - DISTRICT 8

SCALE: 1/4" = 1'-0"A111

E1 RCP - DISTRICT 7

RECEPTION

A5

A221

A7

A221

WALL BASE AS

SCHEDULED

WALL FINISH AS

SCHEDULED

8' - 10 3/4"

ST-2

102RECEPTION

A5

A221

Sim A7

A221

Sim

WALL BASE AS

SCHEDULED

WALL FINISH AS

SCHEDULED

7' - 10 5/8"

ST-1

LEV 05

60' - 0"

EXISTING ROOF DECK

RECEPTION

WORK

ROOM

EXISTING CONCRETE SLAB

WALL BASE AS

SCHEDULED

A601

E7

A601

A7

EXISTING ROOF SYSTEM

EXISTING ROOF MTL DECK

CEILING AS SCHEDULED

LEV 05

60' - 0"

RECEPTION

WORK

ROOM

EXISTING ROOF DECK

EXISTING CONCRETE SLAB

A601

E5

EXISTING ROOF SYSTEM

EXISTING ROOF MTL DECK

CEILING AS SCHEDULED

DOOR AND FRAME

AS SCHEDULED

LEV 05

60' - 0"

EXISTING CONCRETE SLAB

WALL BASE AS

SCHEDULED

EXISTING ROOF SYSTEM

EXISTING ROOF MTL DECK

CEILING AS SCHEDULED

COMMISSIONER

OFFICE

EXISTING

BREAK ROOM

EXISTING STUD WALL AND

GYPSUM BOARD TO

REMAIN ON THE BREAK

ROOM SIDE

VERIFY THAT THE EXISTING STUDS

RUN CONTINUOUSLY FROM FLOOR

TO DECK WITHOUT GAPS. INSTALL

FULL-HEIGHT BATT INSULATION.

APPLY TWO LAYERS OF GYPSUM

BOARD FROM FLOOR TO DECK AFTER

INSULATION.

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

A221

INTERIOR SECTIONS

& ELEVATIONS

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - INTERIOR ELEVATIONS

A WHERE EXISTING FLOORING MATERIALS ARE SCHEDULED FOR REMOVAL:

a) REMOVE EXISTING BASE MATERIAL AND PROVIDE NEW BASE AS SCHEDULED

b) PREPARE FLOOR SURFACE TO ACCEPT NEW FLOORING MATERIAL AS

SCHEDULED. WORK SHALL INCLUDE, BUT IS NOT BE LIMITED TO FLOOR LEVELING,

SLAB REPAIR, COMPLETE REMOVAL OF EXISTING FINISHES/ADHESIVES AND

TRANSITION ADJUSTMENT WHEN NEW OPENINGS ARE CUT IN EXISTING WALLS OR

WHERE WALLS ARE REMOVED.

B ALL WALL BASE SHALL BE TYPE RB-X, UNO.

C REFER TO SHEET A113 FOR FINISHES AND MATERIALS

SCALE: 1/2" = 1'-0"A221

E7 INTERIOR ELEVATION - DISTRICT 8

SCALE: 1/2" = 1'-0"A221

E4 INTERIOR ELEVATION - DISTRICT 7

SCALE: 3/4" = 1'-0"A221

A5 WALL SECTION

SCALE: 3/4" = 1'-0"A221

A7 WALL SECTION

SCALE: 3/4" = 1'-0"A221

A2 WALL SECTION

DOOR MATERIAL ABBREVIATIONS

AL ALUMINUM

CR ACCESS CONTROL CARD READER

FF FACTORY FINISH

GL GLAZING

HM HOLLOW METAL DOOR/ OR FRAME

N/A NOT APPLICABLE

PNT PAINTED

WD SOLID CORE WOOD DOOR

STC SOUND TRANSMITTING COEFFICIENT

DOOR SCHEDULE NOTES

1. ACCESS-CONTROLLED CARD READER AT THIS LOCATION;

REFER TO ELECTRICAL / TECHNOLOGY DRAWINGS FOR

ADDITIONAL INFORMATION

GLAZING MATERIAL TYPES

G1 INTERIOR 1/4-INCH GLASS

PARTITION AS

SCHEDULED

DOUBLE JAMB STUDS

(16 GA MIN)

CONT SEAL AROUND

PERIMETER OF FRAME

DOOR AND FRAME

AS SCHEDULED

W A

L L

W T

H

DOUBLE JAMB

STUDS

DOOR AND FRAME

AS SCHEDULED

CONT SEAL AROUND

PERIMETER

OF FRAME

GYP BOARD

WALL WIDTH + 1

PARTITION AS

SCHEDULED

SOFFIT/CEILING

WHERE OCCURS

DOOR PANEL

TYPE A

FLUSH DOOR

DOOR FRAME

TYPE F1

A S

S C

H E

D U

L E

D

D O

O R

O P

E N

IN

G

H E

IG

H

T

AS SCHEDULED

DR WIDTH2" 2"

C5/A601

E /A

SEALANT AND

BACKER ROD

GLAZING AS

SCHEDULED

FRAME SYSTEM

AS SCHEDULED

PARTITION AS

SCHEDULED

SOFFIT/CEILING

WHERE OCCURS

DOUBLE HEAD STUDS

(16 GA MIN) IN CONT

RUNNER TOP AND BOTTOM

CONTINUOUS "J" BEAD,

AT BOTH SIDES TYP2

/2

5"

FRAME SYSTEM

AS SCHEDULED

GLAZING AS

SCHEDULED

SEALANT AND

BACKER ROD

2 1/2"

PARTITION AS

SCHEDULED

DOUBLE JAMB STUDS

(16 GA MIN)

SEALANT AND

BACKER ROD

GLAZING AS

SCHEDULED

FRAME SYSTEM

AS SCHEDULED

5"

PARTITION AS

SCHEDULED

DOUBLE HEAD STUDS

(16 GA MIN) IN CONT

RUNNER TOP AND BOT

CONTINUOUS "J" BEAD,

AT BOTH SIDES TYP

/2

7' - 10 5/8"

STOREFRONT

ST-1

G1 G1 G1 G1 G1

EQEQEQEQEQ

8' - 10 3/4"

EQ EQ EQ EQ EQ

G1 G1 G1 G1 G1

STOREFRONT

ST-2

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

A601

DOOR SCHEDULE &

DETAILS

LG

MA

08/272025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

GENERAL NOTES - DOOR & WINDOW

A PROVIDE FRAME ROUGH OPENINGS AS RECOMMENDED BY FRAME

MANUFACTURER.

B REFER TO FINISH SCHEDULE FOR ALL FINISH MATERIALS AND FINISH

LOCATIONS

D CONTRACTOR TO SHALL COORDINATE AND PROVIDE BLOCKING WHERE

WALL STOPS ARE REQUIRED.

E FIELD VERIFY ALL OPENINGS PRIOR TO FABRICATION.

DOOR SCHEDULE

MARK

ROOM

NUMBER ROOM NAME

DOOR FRAME

HARDWARE NOTESDOOR SIZE THICK MAT'L FINISH RATING TYPE GLAZ MAT'L TYPE GLAZ FINISH

FP 03 - OVERALL

107 3'-0" x 8'-0" 1 3/4" WD N/A A N/A HM F1 PT

FP 03 - OVERALL: 1

LEV 05

100 100 EXISTING

COORIDOR

3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 02 1

101 101 RECEPTION 3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 03

102 102 WORK ROOM 3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 04

103 103 COMMISSIONER

OFFICE

3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 04

104 104 RECEPTION 3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 01

105 105 WORK ROOM 3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 04

106 106 COMMISSIONER

OFFICE

3'-0" x 8'-0" 1 3/4" WD STAINED N/A A N/A HM F1 N/A PT 04

LEV 05: 7

Grand total: 8

SCALE: 3" = 1'-0"A601

C5 HM FRAME - JAMB

SCALE: 3" = 1'-0"A601

E5 HM FRAME - HEAD

SCALE: 3" = 1'-0"A601

E7 STOREFRONT DETAIL - HEAD

SCALE: 3" = 1'-0"A601

C7 STOREFRONT DETAIL - JAMB

SCALE: 3" = 1'-0"A601

A7 STOREFRONT DETAIL - SILL

OCCUPIED OCCUPIED OCCUPIED

OCCUPIEDOCCUPIEDOCCUPIED

OCCUPIED

OCCUPIED

OCCUPIED

OCCUPIED VACANT

VACANT

VACANT

VACANT

VACANT

OCCUPIED

F.E.C.

OFFICE

JUNIOR

ATTORNEY 302

ATTORNEY

ATTORNEY

ATTORNEY

ATTORNEY

ATTORNEY

ATTORNEY

JUNIOR

ATTORNEY 309

OFFICE

FILES

WORKING

AREA

WORKING

AREA

WORKING

AREA

PARALEGAL

CONFERENCE

CONFERENCE

COFFEE

COPY/FAX

CONFERENCE

ELEC.

TEL.

WOMEN'S

MEN'S

CONFERENCE

CONFERENCE

RECEPTION

CORRIDOR

RECEPTION

WORK AREA

MECHANICAL

SERVICE

LOBBY

ELECTRICAL

STAIR

CONFERENCE

FBS

FILES

COUNTY

ATTORNEY

SUPPORT

CORRIDOR

WOMEN'S

MEN'S

LOBBY

CORRIDOR

OMB

FILES

ASST.

MANAGER

OFFICE

OFFICE

OFFICE

OFFICE

DEPT.

MANAG.

OFFICE

OFFICE

AGENDA

DEVELOP.

REFERENCE

COPY

CENTER

CLOSET

ELEC.

TEL.

ELEVATOR

LOBBY

CORRIDOR

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

STAIR

VESTIBULE

VESTIBULE

ELEC.

TEL.

TEL.

ELEC.

ASSISTANT

RECEPTION

JUNIOR

ATTORNEY

317C

OFFICE

WORKING

AREA

WORKING

AREA

C O R R

ID

O R

RECEPTION

CONFERENCE

COPY/FAX

CONFERENCE

COPY/FAX/

SUPPLIES

VESTIBULE

VESTIBULE

OFFICE

OFFICE

WORKING

AREA

CORRIDOR

WORKING

AREA

VESTIBULE

348A

BRIDGE

BREAK ROOM

COFFEE

COPY/FAX

WORKING AREA

GENERAL OFFICE

3009A

OFFICE

MECH

OFFICE

OFFICE

OFFICE

CONFERENCE

ELEVATOR

VESTIBULE

MECH

EXTERIOR

EMPLOYEE LOUNGE

STORAGE

CHAIRMAN'S

STORAGE

RECEPTION

EXTERIOR

ORANGE TV STUDIO

317A

OFFICE

317B

OFFICE

3009B

WORK ROOM

320B

OFFICE

320A

CORR

320C

OFFICE

OFFICE

A112

A1

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

3/32" = 1'-0"

A101

LOCATION PLAN-

LEVEL 3

LG

MA

08/27/2025

18019

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

SCALE: 3/32" = 1'-0"A101

1 NEW WORK LOCATION PLAN - LEVEL 3

COPY/FAX

CONFERENCE

CORRIDOR

F00

FFE PLAN LEGEND

FURNITURE- PROCURED AND

INSTALLED BY GC

FFE PLAN NOTES

1. ALL EXTERIOR WINDOWS TO RECEIVE

WINDOW TREATMENTS, GC PROVIDED AND

INSTALLED.

2. ALL EQUIPMENT DESIGNED TO BE

PERMANENTLY MOUNTED SHALL BE

SECURELY ANCHORED TO IT'S

SUPPORTING SURFACE PER FBC 453.14.7.

3. 5% MINIMUM EMPLOYEE WORKSTATIONS

TO BE ADA COMPLIANT.

4. COORDINATE FINAL LOCATION OF ALL

SIGNAGE WITH ARCHITECT.

5. SUBMIT SIGNAGE TEXT SCHEDULE FOR

EACH SIGN FOR OWNERS

REPRESENTATIVE TO REVIEW.

FINISH PLAN NOTES

1. CONTRACTOR SHALL PROVIDE ALL

INTERIOR FINISHES AS SPECIFIED HEREIN.

ARCHITECT SHALL BE NOTIFIED OF ANY

DISCREPANCIES OR OMISSIONS PRIOR TO

PROCEEDING WITH WORK.

2. ALL FINISHES SHALL MEET OR EXCEED THE

FLAME SPREAD INDEX PROVIDED IN FBC-B

TABLE 803.5, CLASS C OR BETTER AND

NFPA 101, SECTION 10.2.

3. ALL MISCELLANEOUS GRILLES, PLATES, OR

OTHER DEVICES SHALL BE SPRAY PAINTED

TO MATCH ADJACENT SURFACES IN WHICH

THEY ARE BEING INSTALLED.

4. ALL WALL SURFACES SHALL BE PAINTED

FROM CORNER TO CORNER WHERE NEW

WORK EFFECTS EXISTING WALLS.

5. ALL FINISHES IMPACTED BY NEW WORK IN

EXISTING BUILDING SHALL BE PATCHED,

REPAIRED, AND REFINISHED TO MAKE AS

NEW.

6. ALL WALLS THAT ARE NOT NOTED WITH

ACCENT COLOR ARE TO BE PAINTED PNT-1.

7. ALL WALLS TO BE LIGHT TEXTURED FINISH

WITH LEVEL 4 FINISH OR BETTER.

8. PAINT FOR WALL FINISHES SHALL BE

PROVIDED AS A (3) COAT EGGSHELL LATEX

ENAMEL PAINT INSTALLATION- (1) PRIME

AND (2) FINISH COATS; COLORS AS

SPECIFIED.

BASIS OF DESIGN MATERIALS

OR APPROVED EQUAL

CPT01

MNF: BENTLEY MILLS

SERIES: REDACTED

COLOR: DOCUMENT 801532

NOTES: 18 X 36 WITH HARD BACK

LVT01

MNF: PARTEREE LUXURY FLOORING

SERIES: INGRAINED

COLOR: 11352 SOTA OAK

NOTES: 7.25" X 48" PLANK

PNT01

MNF: SHERWIN WILLIAMS

SERIES: LOW VOC

COLOR: SW7056 RESERVED WHITE

NOTES: EGGSHELL FINISH

PNT02

MNF: SHERWIN WILLIAMS

SERIES: LOW VOC

COLOR: SW7044 AMAZIN GRAY

NOTES: EGGSHELL FINISH

VB01

MNF: JOHNSONITE

SERIES: 4" VINYL COVE

COLOR: CEMEMENT 121

CPT01

VB01

PNT01

EXISITNG WAINSCOT TO REMAIN, REMOVE ALL

PICTURE FRAMING TRIM THROUGHOUT

REMOVE EXISTING WALL COVERING, PATCH AND

REPAIR WALLS AS REQUIRED TO RECIEVE PAINT

EXISTING CEILING, LIGHTING, AND FFE TO

REMAIN, PROTECT DURING REPLACEMENT OF

FINISHES

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

A112

FFE AND FINISH

FLOOR PLANS LEVEL

LG

MW

08/272025

18019

Lori M. Godbold

AR101739

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

SCALE: 1/4" = 1'-0"A112

A1 FINISH FLOOR PLAN- LEVEL 3

DATE SUBMISSION/REVISION NO.

mwann Text Box

AMANDA WANNEN

ID5177

COMMISSIONER

OFFICE

WORK

ROOM

EXISTING

WORKING

AREA

EXISTING

COORIDOR

STR1

STR2

STR2

STR2

STR1

CH2

CH1

CH1

CH1 CH1

CH1

CH1CH1

CH1 TB1

CH1

CH1

TB2 LNG1

DSK1

DSK2

CH2

CH2

CH2 CH2

DSK3 DSK3

STR3

STR3

STR3

DSK2

COMMISSIONER

OFFICE

RECEPTION

WORK

ROOM

EXISTING BREAK ROOM

CH2

CH2

CH2

CH2

CH1

CH1 CH1

CH1 CH1

CH2

CH3

TB3

CH3

CH3

CH3

STR4 STR4

DSK3

DSK1

STR2 STR2 STR2

STR4 STR2 STR2 STR2

DSK4DSK5

F00

FFE PLAN LEGEND

FURNITURE- PROCURED AND

INSTALLED BY GC

FFE PLAN NOTES

1. ALL EXTERIOR WINDOWS TO RECEIVE

WINDOW TREATMENTS, GC PROVIDED AND

INSTALLED.

2. ALL EQUIPMENT DESIGNED TO BE

PERMANENTLY MOUNTED SHALL BE

SECURELY ANCHORED TO IT'S

SUPPORTING SURFACE PER FBC 453.14.7.

3. 5% MINIMUM EMPLOYEE WORKSTATIONS

TO BE ADA COMPLIANT.

4. COORDINATE FINAL LOCATION OF ALL

SIGNAGE WITH ARCHITECT.

5. SUBMIT SIGNAGE TEXT SCHEDULE FOR

EACH SIGN FOR OWNERS

REPRESENTATIVE TO REVIEW.

FINISH PLAN NOTES

1. CONTRACTOR SHALL PROVIDE ALL

INTERIOR FINISHES AS SPECIFIED HEREIN.

ARCHITECT SHALL BE NOTIFIED OF ANY

DISCREPANCIES OR OMISSIONS PRIOR TO

PROCEEDING WITH WORK.

2. ALL FINISHES SHALL MEET OR EXCEED THE

FLAME SPREAD INDEX PROVIDED IN FBC-B

TABLE 803.5, CLASS C OR BETTER AND

NFPA 101, SECTION 10.2.

3. ALL MISCELLANEOUS GRILLES, PLATES, OR

OTHER DEVICES SHALL BE SPRAY PAINTED

TO MATCH ADJACENT SURFACES IN WHICH

THEY ARE BEING INSTALLED.

4. ALL WALL SURFACES SHALL BE PAINTED

FROM CORNER TO CORNER WHERE NEW

WORK EFFECTS EXISTING WALLS.

5. ALL FINISHES IMPACTED BY NEW WORK IN

EXISTING BUILDING SHALL BE PATCHED,

REPAIRED, AND REFINISHED TO MAKE AS

NEW.

6. ALL WALLS THAT ARE NOT NOTED WITH

ACCENT COLOR ARE TO BE PAINTED PNT-1.

7. ALL WALLS TO BE LIGHT TEXTURED FINISH

WITH LEVEL 4 FINISH OR BETTER.

8. PAINT FOR WALL FINISHES SHALL BE

PROVIDED AS A (3) COAT EGGSHELL LATEX

ENAMEL PAINT INSTALLATION- (1) PRIME

AND (2) FINISH COATS; COLORS AS

SPECIFIED.

BASIS OF DESIGN MATERIALS

OR APPROVED EQUAL

CPT01

MNF: BENTLEY MILLS

SERIES: REDACTED

COLOR: DOCUMENT 801532

NOTES: 18 X 36 WITH HARD BACK

LVT01

MNF: PARTEREE LUXURY FLOORING

SERIES: INGRAINED

COLOR: 11352 SOTA OAK

NOTES: 7.25" X 48" PLANK

PNT01

MNF: SHERWIN WILLIAMS

SERIES: LOW VOC

COLOR: SW7056 RESERVED WHITE

NOTES: EGGSHELL FINISH

PNT02

MNF: SHERWIN WILLIAMS

SERIES: LOW VOC

COLOR: SW7044 AMAZIN GRAY

NOTES: EGGSHELL FINISH

VB01

MNF: JOHNSONITE

SERIES: 4" VINYL COVE

COLOR: CEMEMENT 121

A221

E4

RECEPTION

COMMISSIONER

OFFICE

WORK

ROOM

EXISTING

WORKING

AREA

EXISTING

COORIDOR

PAINT INFILL AND NEW PARTITION TO MATCH ADJACENT EXISTING PARTITION

PAINT NEW PARTITION

TO MATCH ADJACENT

EXISTING PARTITION

A C

C E

N T

P N

T

A C

C E

N T

P N

T

LVT01

VB01

PNT01

LVT01

VB01

PNT01

LVT01

VB01

PNT01

A601

A221E7

COMMISSIONER

OFFICE

RECEPTION

WORK

ROOM

EXISTING BREAK ROOM

P A

IN

T

I N

F

IL

P

A R

T

IT

IO

N

T O

M

T

C H

A D

J A

C E

N T

E

X

IS

T

IN

G

P

R T

IT

IO

N

LVT01

B01

PNT01

ACCENT WALL PNT02

LVT01

B01

PNT01

LVT01

B01

PNT01

A6012

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

Consultants

Client

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AR0014284

www.rbarchitects.com 407.648.7288

As indicated

A113

FFE AND FINISH

FLOOR PLANS LEVEL

LG

MW

08/27/2025

18019

Lori M. Godbold

AR101739

ORANGE COUNTY

ADMINSTRATION

CENTER

REDISTRICTING

RENOVATION

201 S. ROSALIND AVE.

ORLANDO, FL 32801

ORANGE COUNTY

GOVERNMENT

CONSTRUCTION DOCUMENTS

SCALE: 1/4" = 1'-0"A113

A1 FFE FLOOR PLAN - DISTRICT 7

SCALE: 1/4" = 1'-0"A113

A6 FFE FLOOR PLAN - DISTRICT 8

SCALE: 1/4" = 1'-0"A113

E1 FINISH FLOOR PLAN - DISTRICT 7

SCALE: 1/4" = 1'-0"A113

E6 FINISH FLOOR PLAN - DISTRICT 8

Furniture Schedule-Basis of Design- Contractor Provided and Installed

Type Mark Description

CH1 SIDE CHAIR- OWNER PROVIDED UNDER SEPARATE BUDGET

CH2 TASK CHAIR- OWNER PROVIDED UNDER SEPARATE BUDGET

CH3 SIDE CHAIR- OWNER PROVIDED UNDER SEPARATE BUDGET

DSK1 DESK- KI FURNITURE- ORENDA CASEWGOODS,L SHAPED

DSK2 DESK- KI FURNITURE- ORENDA CASEWGOODS,L SHAPED

DSK3 DESK- KI FURNITURE- ORENDA SINGLE DESK

DSK4 DESK- KI FURNITURE- ORENDA DESK, L SHAPED

DSK5 DESK- KI FURNITURE- ORENDA DESK, L SHAPED

LNG1 LOUNGE SOFA- OWNER…

This is the start of the file's text. The full file is on GovTribe.