Y25-724_Drawings.pdf
PDF 20 MB Posted
- Attached to
- Northwest Water Reclamation Facility Package 1 Clarifiers #1-#4, WAS, Meter & Lab Improvements
- Solicitation number
- Y25-724
- Issued by
- Orange County, Orlando City, Florida
About this file
These construction drawings detail the Orange County Northern Water Reclamation Facility's Clarifiers #1-#4, Waste Activated Sludge (WAS), Meter, and Laboratory Improvements project located in Apopka, Florida. The comprehensive set of 51 technical drawings, prepared by CHA Consulting, Inc. for Orange County Utilities, covers multiple disciplines including civil, architectural, structural, process mechanical, HVAC, plumbing, electrical, and instrumentation. The project involves significant renovations and upgrades to four existing clarifiers, including replacement of clarifier mechanisms, scum troughs, drives, walkways, and platforms, installation of weir washing systems, flow meter modifications, and laboratory improvements.
The project is estimated to cost $7,213,000.00 and is scheduled to be bid electronically through the OpenGov e-Procurement Platform, with sealed offers accepted until 4:00 pm EST on Tuesday, January 14, 2025. Bidders are required to create a free account on the platform and submit responses electronically. The drawings indicate detailed specifications for equipment replacement, electrical system upgrades, piping modifications, and architectural renovations within the water reclamation facility. Key components include new clarifier bridges, drive units, walkways, electrical power plans, instrumentation modifications, and laboratory space updates. The project appears to be funded by Orange County and aims to improve the facility's operational efficiency and infrastructure reliability.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P a re n t S h e e t S e t:
In d iv id u a l F ile
P a th
R e v/
P lo t b y:
R e v o n
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/1
/2
:5
A M
V
P ro je ct s\ W
S F
L
\P ro j1 \0
.0
\0
D e si g n
\D ra w in g s\
S h e e ts
\G
.d w g
REV DATE DESCRIPTION BY
NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB
IMPROVEMENTS
A 09/2022 60% DRAWINGS AJM
100% ISSUED FOR BID
CHA Project No. 071402
PROJECT TEAM
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
ORLANDO, FLORIDA 32835
COA# 6160
EMI CONSULTING SPECIALTIES, INC.
5742 River Bed Road Groveland, FL 34736
(352) 460-4035
The Villages, FL 32162
Thomas E. Cunningham
1692 Duffy Loop Architect
407.595.1496 TecArch2015@outlook.com
CONSTRUCTION DRAWINGS
FOR THE
NOT FOR CONSTRUCTION
CAP NO. 1435-0023
SEQUENCE NO. 98599
PREPARED FOR:
ORANGE COUNTY UTILITIES
ORANGE COUNTY, FLORIDA
ATTENTION IS DIRECTED TO THE FACT THAT THESE
PLANS MAY HAVE BEEN REDUCED IN SIZE BY
REPRODUCTION. THIS MUST BE CONSIDERED WHEN
OBTAINING SCALED DATA. DIMENSION
INFORMATION SHOULD NOT BE OBTAINED BY
SCALING THE PLANS. DIMENSION INFORMATION
NOT PROVIDED HEREIN CAN BE OBTAINED BY
CONTACTING ORANGE COUNTY UTILITIES
ENGINEERING DIVISION, AT (407)254-9900
ORANGE COUNTY UTILITIES
ENGINEERING DIVISION
9150 CURRY FORD ROAD, 2ND FLOOR
ORLANDO, FL 32825
PHONE: 407-254-9900
BOARD OF COUNTY COMMISSIONERS
JERRY L. DEMINGS
COUNTY MAYOR
NICOLE H. WILSON
District 1
MARIBEL GOMEZ CORDERO
District 4
CHRISTINE MOORE
District 2
EMILY BONILLA
District 5
MAYRA URIBE
District 3
MICHAEL SCOTT
District 6
BYRON W. BROOKS, AICP
County Administrator
ED TORRES, MS, PE, LEED AP
Director Orange County Utilities Department
JUNE 2024
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
1016 SPRING VILLAS POINT
WINTER SPRINGS, FL 32708
TEL: (407) 679-5358
CHA CONSULTING, INC.
CERTIFICATE OF AUTHORIZATION #28386
1320 WILFRED DRIVE
ORLANDO, FL 32803
P: 407.219.4454 COA No: 31920
WEKIVA PROJECT #XX-XXX
SHEET NO.:
REVISION:
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
A 09/2022 60% DRAWINGS AJM
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
MARK WORSHAM, State of Florida, Professional Engineer, License Number 66379
This item has been digitally signed and sealed by MARK WORSHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. (407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CERTIFICATE OF AUTH. 28386
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
GENERAL
LOCATION MAPS AND DRAWING INDEX
G02 02
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/2
/2
:4 A
M V
P ro je ct s\
W S
F L
\P ro j1
\0
.0
\0
D e si g n \D ra w in g s\
S h e e ts \G
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
MKW
AJM
JLH
MAB
MKW
DRAWING INDEX
GULF OF MEXICO
ATLANTIC OCEAN
ORANGE
COUNTY
STATE OF FLORIDA
SCALE: N.T.S.
ORANGE COUNTY, FLORIDA
SCALE: N.T.S.
LA
K
E C
O U
N
TY
LAKE COUNTY
LAKE
APOPKA
ORLANDO
INTERNATIONAL
AIRPORT
APOPKA
MAITLAND
WINTER PARK
WINTER
GARDEN
HIAWASSEE
PINE HILLS
ORLANDO
MEADOW
WOODS
HUNTERS
CREEK
LAKE
NONA
OCOEE
BAY LAKE
DOCTOR
PHILLIPS
WINDERMERE
GOTHA
ZELLWOOD
WEKIWA
SPRINGS
STATE PARK
HAL SCOTT
REGIONAL
PRESERVE
AND PARK
SEMINOLE
RANCH WMA
TOSOHATCHEE
WILDLIFE
MANAGEMENT
AREA
CHRISTMAS
SEMINOLE COUNTY
OSCEOLA COUNTY
BR
EVAR
D C
O U
N
TY
ST
JO
HNS
R
IVER
FLORIDA
TURNPIKE
PROJECT LOCATION
SHEETDRAWING DESCRIPTION
GENERAL
01 G01 COVER
02 G02 LOCATION MAPS AND DRAWING INDEX
03 G03 ABBREVIATIONS
04 G04 SYMBOLS AND LEGENDS
05 G05 GENERAL CONSTRUCTION NOTES
CIVIL
06 C01 SITE PLAN / DEMOLITION PLAN
07 C02 YARD PIPING PLAN
ARCHITECTURAL
08 A01 KEY PLAN, DEMOLITION PLAN, AND NOTES
09 A02 FLOOR PLAN, CEILING PLAN, AND INTERIOR ELEVATIONS
10 A03 SCHEDULES, AND DETAILS
STRUCTURAL
11 S01 GENERAL STRUCTURAL NOTES
12 S02 SLAB PLANS AND DETAILS
13 S03 TYPICAL STRUCTURAL DETAILS
PROCESS MECHANICAL
14 PM01 MECHANICAL PLAN
15 PM02 CLARIFIERS #1 AND #2 TOP PLAN
16 PM03 CLARIFIERS #3 AND #4 TOP PLAN
17 PM04 CLARIFIERS #1-#4 PLAN AND ELEVATION DETAILS
18 PM05 CLARIFIERS #1 AND #2 WAS FLOW METER PLAN AND ELEVATION
19 PM06 WEIR WASH SYSTEM PUMP STATION PLAN AND SECTION
20 PM07 PLUG VALVE REPLACEMENT AND DETAILS
HVAC
21 H01 SYMBOLS
22 H02 LABORATORY PLAN
23 H03 SCHEDULES & DETAILS
PLUMBING
24 P01 SYMBOLS
25 P02 LABORATORY PLAN
ELECTRICAL
26 E01 ELECTRICAL NOTES, SYBMOLS AND ABBREVIATIONS
27 E02 OVERALL SITE PLAN
28 E03 80-MCC-1 SINGLE LINE DIAGRAM
29 E04 80-MCC-2 SINGLE LINE DIAGRAM
30 E05 MCC-G1 SINGLE LINE DIAGRAM
31 E06 MCC-G2 SINGLE LINE DIAGRAM
32 E07 80-MCC-1, 80-MCC-2, MCC-G1, MCC-G2, FRONT VIEWS
33 E08 ELEMENTARY AND RISER DIAGRAMS
34 E09 EXISTING AIR COMPRESSOR BUILDING ELECTRICAL PLAN
35 E10 OLD GENERATION BUILDING PWER PLAN (MODIFICATIONS)
36 E11 ELECTRICAL LAB PLANS
37 E12 CLARIFIERS #1 AND #2 ELCTRICAL POWER PLAN
38 E13 CLARIFIERS #3 AND #4 ELCTRICAL POWER PLAN
39 E14 CLARIFIERS #1 AND #2 WAS FLOW METER PLAN
40 E15 WEIR WASH SYSTEM PUMP STATION ELECTRICAL POWER PLAN
41 E16 WEIR WASH SYSTEM PUMP STATION ELECTRICAL POWER PLAN
42 E17 LIGHTING FIXTURE SCHEDULE AND DETAILS
43 E18 ELECTRICAL DETAILS 2
44 E19 ELECTRICAL DETAILS 3
INSTRUMENTATION & CONTROLS
45 I01 INSTRUMENTATION SYMBOLS, LEGEND AND ABBREVIATIONS
46 I02 NWRF CLARIFIERS NO. 1 & 2
47 I03 NWRF CLARIFIERS NO. 3 & 4
48 I04 WEIR WASHER SYSTEM AND BNR FLOW CONTROL
49 I05 PLC-03 AND PLC-04 NETWORK BLOCK DIAGRAM
50 I06 INSTRUMENTATION DETAILS 1
51 I07 INSTRUMENTATION DETAILS 2
NORTHERN WATER RELAMATION FACILITY
SCALE: N.T.S.
SITE LOCATION
701 WEST MCCORMICK ROAD
APOPKA, FL 32703
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
A 09/2022 60% DRAWINGS AJM
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
MARK WORSHAM, State of Florida, Professional Engineer, License Number 66379
This item has been digitally signed and sealed by MARK WORSHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. (407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CERTIFICATE OF AUTH. 28386
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
GENERAL
ABBREVIATIONS
G03 03
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/3 /2
:0
A
M V
P ro je ct s\
W S
F L
\P ro j1
\0
.0
\0
D e si g n \D ra w in g s\
S h e e ts \G
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
DBL DOUBLE
DEG DEGREE
DEPT DEPARTMENT
DET DETAIL
DF DIESEL FUEL
DI DROP INLET, DUCTILE IRON
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DIP DUCTILE IRON PIPE
DISCH DISCHARGE
DISP DISPENSER
DIST DISTRIBUTION
DIV DIVISION
DJ DISMANTLING JOINT
DM DAMPER MOTOR
DMH DROP MANHOLE
DMJ DOUBLE MECHANICAL JOINT
DN DOWN
DO DOOR OPENING, DISSOLVED OXYGEN
DRN DRAIN
DS DOWNSPOUT
DV DRAIN VALVE, DIAPHRAGM VALVE
DW DISINFECTED WATER
DWG(S) DRAWING(S)
DWL(S) DOWEL(S)
DWV DRAIN, WASTE, AND VENT
E EAST(ING), ELECTRICAL
EA EACH
EC END CURVE
ECC ECCENTRIC
EEW EMERGENCY EYEWASH
EF EACH FACE
EFF EFFLUENT
EGO ELEVATED GEAR OPERATOR
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC, (AL)
ELEV ELEVATOR
ELL ELBOW - PLUMBING SMALLER THAN 4"
EMER EMERGENCY
ENC ENCASEMENT
ENCL ENCLOSURE
ENT ENTRANCE
EOL END OF LINE
EOP EDGE OF PAVEMENT
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
EVA ELECTRIC VALVE ACTUATOR
EW EACH WAY
EWEF EACH WAY EACH FACE
EXCH EXCHANGER
EXIST EXISTING
EXP EXPANSION, EXPOSED
EXT EXTENSION, EXTERIOR, EXTERNAL
F/F FACE TO FACE
FAB FABRICATED
FC FLEXIBLE CONNECTION, FLOW CONTROL
FCA FLANGED COUPLING ADAPTER
FCV FLOW-CONTROL VALVE
FD FLOOR DRAIN, FOUNDATION DRAIN
FDN FOUNDATION
FE FILTER EFFLUENT
FF FINISH FLOOR
FG FIBERGLASS
FH FIRE HYDRANT
FIG FIGURE
FIN FINISH
FL FLOOR, FLOW LINE
FLEX FLEXIBLE
FLG FLANGE
FM FORCE MAIN, FLOW METER
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRP FIBERGLASS REINFORCED PLASTIC
FS FAR SIDE, FLOOR SLEEVE, FLOAT SWITCH
FT FOOT
FURN FURNISH, FURNISHED
FV FLAP VALVE
FW FINISHED WATER
FWD FORWARD
G GAS
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC/MS GAS CHROMATOGRAPH/MASS SPECTROMETER
GEN GENERAL, GENERATOR
GIP GALVANIZED IRON PIPE
GJ GROOVE JOINT
GM GAS METER
GND GROUND
GO GEAR OPERATED
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPS GALLONS PER SECOND
GR GRADE
GS GALVANIZED STEEL
GSP GALVANIZED STEEL PIPE
GSR GROUND STORAGE RESERVOIR
GST GROUND STORAGE TANK
GV GATE VALVE
A ACID, AIR
AB ANCHOR BOLT
ABAN ABANDON(ED)
ABS ACRYLONITRILE BUTADIENE STYRENE
A/C AIR CONDITIONER, (ING)
ACCMP ASPHALT-COATED CORRUGATED METAL PIPE
ACP ASBESTOS CEMENT PIPE
ADD ADDITIONAL
ADH ADHESIVE
ADJ ADJUSTABLE, ADJACENT
ADMIN ADMINISTRATION
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE, (IVE)
ALUM ALUMINUM
AOD ANGLE OF DEFLECTION
AP ACCESS PANEL
APPR APPROACH
APPROX APPROXIMATE, (LY)
ARCH ARCHITECTURAL
ARV AIR RELEASE VALVE
ARVV AIR RELEASE AND VACUUM VALVE
ASSY ASSEMBLY
AUTO AUTOMATIC
AUX AUXILIARY
AVS AUTOMATIC VALVE STATION
AWG AMERICAN WIRE GAGE
BC BEGIN CURVE
BCV BALL CHECK VALVE
BF BLIND FLANGE
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VALVE
BGO BURIED GEAR OPERATOR
BI BLACK IRON
BIP BLACK IRON PIPE
BITUM BITUMINOUS
BKR BREAKER
BLDG BUILDING
BLK BLOCK
BM BENCHMARK
BOC BACK OF CURB
BOF BOTTOM OF FOOTING
BOS BOTTOM OF SLAB, BOTTOM OF SLOPE
BOT BOTTOM
BRG BEARING
B&S BELL AND SPIGOT
BSMT BASEMENT
BSP BLACK STEEL PIPE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT-HOUR
BU BELL-UP
BV BALL VALVE
BVC BEGIN VERTICAL CURVE
BWW BACKWASH WATER
C/C CENTER TO CENTER
CATV CABLE TELEVISION
CAV COMBINATION AIR VALVE
CB CATCH BASIN
CCC CHLORINE CONTACT CHAMBER
CF CUBIC FOOT
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
C&G CURB AND GUTTER
CHKD CHECKERED
CI CAST IRON, CUBIC INCH
CIMH CAST IRON MANHOLE
CIMHS CAST IRON MANHOLE STEPS
CIP CAST IRON PIPE
CISP CAST IRON SOIL PIPE
CJ CONSTRUCTION JOINT
CJT CONTROL JOINT
CL CENTERLINE
CLF CHAIN LINK FENCE
CLR CLEAR, (ANCE)
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT, COMPANY
COD CHEMICAL OXYGEN DEMAND
COMB COMBINATION
COMB SWR COMBINED SEWER
COMP COMPRESSOR, (ED)
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCT, CONSTRUCTION
CONT CONTINUOUS(LY), CONTINUATION
COP COPPER PIPE
COR CORNER
CORR CORRIDOR, CORRUGATED
CP CONCRETE PIPE
CPLG COUPLING
CPP CONCRETE PRESSURE PIPE
CPVC CHLORINATED POLYVINYL CHLORIDE
CS CHLORINE SOLUTION
CTR(S) CENTER(S)
CTRL CONTROL
CV CHECK VALVE
CW COLD WATER
CY CUBIC YARD
H HIGH, HOUR, HYDROGEN
HB HOSE BIBB
HDD HORIZONTAL DIRECTIONAL DRILL
HDPE HIGH-DENSITY POLYETHYLENE
HE HEAT EXCHANGER
HEX HEXAGONAL
HF HOSE FAUCET
HFA HYDROFLUOSILICIC ACID
HFCA HARNESSED FLANGED COUPLING ADAPTER
HH HANDHOLE
HLS HIGH LEVEL SWITCH
HMC HARNESSED MECHANICAL COUPLING
HMJ HARNESSED MECHANICAL JOINT
HORIZ HORIZONTAL
HP HIGH POINT, HORSEPOWER
HPA HIGH PRESSURE AIR
HR HOUR, HANDRAIL
HS HIGH STRENGTH
HSP HIGH SERVICE PUMP
HT HEIGHT
HV HOSE VALVE
HVA HYDRAULIC VALVE ACTUATOR
HVAC HEATING, VENTILATING AND AIR CONDITIONING
HW HOT WATER
HWL HIGH WATER LEVEL
HWY HIGHWAY
HYD HYDRAULIC
HYDRO HYDROPNEUMATIC
I INDICATOR
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH(ES)
INC INCORPORATED
INCL INCLUDING
INCR INCREASE
INF INFLUENT
INST INSTRUMENT, (ATION)
INSUL INSULATE, (ED), (ING)
INT INTERIOR, INTERNAL
INV INVERT
IP IRON PIPE
IPS INTERNATIONAL PIPE STANDARD
IR INTERNAL RECYCLE
IW IRRIGATION WATER
JB JUNCTION BOX
JF JOINT FILLER
JT JOINT
KGV KNIFE GATE VALVE
KO KNOCK OUT
L LEVEL, LOUVER
LAB LABORATORY
LAM LAMINATE(D)
LAT LATERAL
LAV LAVATORY
LB(S) POUNDS
LF LINEAR FEET
LG LENGTH, LONG
LH LEFT HAND
LHDPE LINEAR HGH-DENSITY POLYETHYLENE
LIN LINEAL, LINEAR
LO LOUVER OPENING
LR LONG RADIUS
LS LIFT STATION
LT LEFT
LWL LOW WATER LEVEL
MACH MACHINE
MAINT MAINTENANCE
MAN MANUAL
MAX MAXIMUM
MC MECHANICAL COUPLING
MCC MOTOR CONTROL CENTER
MECH MECHANICAL
MED MEDIUM
MET METAL
MES MITERED END SECTION
MF MICROFILTRATION
MFM MAGNETIC FLOWMETER
MFR(S) MANUFACTURER(S)
MG MILLION GALLONS
MGD MILLION GALLONS PER DAY
MH MANHOLE
MI MILE
MIN MINIMUM, MINUTE
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
MJRG MECHANICAL JOINT RETAINER GLAND
MJTR MECHANICAL JOINT WITH TIE ROD
ML MIXED LIQUOR
MO MASONRY OPENING, MOTOR OPERATED
MP METERING PUMP
MPH MILES PER HOUR
MRPP METAL REINFORCED PLASTIC PIPE
MSL MEAN SEA LEVEL
MTD MOUNTED
MTL MATERIAL
MTR MOTOR
MV MOTORIZED VALVE
MW MANWAY
MWL MEAN WATER LEVEL
N NORTH(ING)
N/A NOT APPLICABLE
NaOCl SODIUM HYPOCHLORITE
NBC NAIL IN BOTTLE CAP
N.C. NORMALLY CLOSED
NE NORTHEAST
NF NANOFILTRATION
N.I.C. NOT IN CONTRACT
N.0. NORMALLY OPEN
N0.(S) NUMBER(S)
NOM NOMINAL
NORM NORMAL
NPT NATIONAL PIPE TAPER
NPW NONPOTABLE WATER
NS NEAR SIDE
N.T.S. NOT TO SCALE
NW NORTHWEST
OC ON CENTER, ODOR CONTROL
OD OUTSIDE DIAMETER
OF OUTSIDE FACE, OVERFLOW
OH OVERHEAD
O&M OPERATION AND MAINTENANCE
OP ORIFICE PLATE
OPER OPERATING
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
OZ OUNCE
PBV PLASTIC BALL VALVE
PC POINT OF CURVE
PCC POINT OF COMPOUND CURVATURE
PCCP PRESTRESSED CONCRETE CYLINDER PIPE
PE PLAIN END
PEP POLYETHYLENE PIPE
PERM PERMEATE
PG PRESSURE GAUGE
PH PIPE HANGER, POST HYDRANT
PI POINT OF INTERSECTION
PIVC POINT OF INTERSECTION ON VERTICAL CURVE
PJ PUSH-ON JOINT
P/L PROPERTY LINE
PL PLATE
PM PROCESS MECHANICAL
PNL(S) PANEL(S)
PNV PINCH VALVE
POB POINT OF BEGINNING
POI POINT OF INTERSECTION
POLY POLYMER
PPD POUNDS PER DAY
PPM PARTS PER MILLION
PROP PROPOSED
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PRW PROCESS WATER
PS PIPE SUPPORT, PUMP STATION
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT, POINT OF TANGENCY
PV PLUG VALVE
PVC POLYVINYL CHLORIDE
PVC-D POLYVINYL CHLORIDE (DOUBLE CONTAINED)
PVCP POLYVINYL CHLORIDE PIPE
PVDF POLYVINYLIDENE FLUORIDE (KYNAR)
PVMT PAVEMENT
PW POTABLE WATER
QTY QUANTITY
R RADIUS, RISER
RAS RETURN ACTIVATED SLUDGE
RAW RAW WATER
RCB REINFORCED CONCRETE BOX
RCCP REINFORCED CONCRETE CYLINDER PIPE
RCHEP REINFORCED CONCRETE HORIZONTAL ELLIPTICAL PIPE
RCP REINFORCED CONCRETE PIPE
RCW RECLAIM WATER
RD ROOF DRAIN, ROAD
RECIRC RECIRCULATING
RECP RECEPTACLE
RED REDUCER, REDUCING
REEW REUSE EFFLUENT WATER
REG REGULATOR, REGULATING
REF REFERENCE
REINF REINFORCING
REJ REJECT
REM REMOVABLE
REQD REQUIRED
RET RETURN
REV REVISION, REVISED, REVERSED
REW RETURN EFFLUENT WATER
RG RETAINER GLAND
RJ RESTRAINED JOINT (BELL)
RMJ RESTRAINED MECHANICAL JOINT
RNG RANGE
RO REVERSE OSMOSIS
ROC RADIUS OF CURVATURE
RPM REVOLUTIONS PER MINUTE
RPZBP REDUCED PRESSURE ZONE BACKFLOW PREVENTER
RR RAILROAD
RS RAW SLUDGE, RAW SEWAGE
RT RIGHT
R/W RIGHT OF WAY
RWW RAW WASTEWATER
S SOUTH
SA SAMPLE LINE
SAN SANITARY
SCH SCHEDULE
SCV SILENT CHECK VALVE
SD STORM DRAIN
SE SOUTHEAST
SEC SECOND
SECT SECTION
SEFF SECONDARY EFFLUENT
SF SQUARE FOOT
SG SLUICE GATE
SHT SHEET
SIM SIMILAR
SL SLUDGE
SM SHEET METAL
SP SUMP PUMP
SPA SPACING, SPACES
SPEC(S) SPECIFICATION(S)
SPLY SUPPLY
SQ SQUARE
SS SANITARY SEWER
SSE SUBSTANDARD EFFLUENT
SST STAINLESS STEEL
ST SELF TAPPING
STA STATION
STD STANDARD
STL STEEL
STM STORMWATER
STOR STORAGE
STR STRAIGHT
STRUC STRUCTURAL
SV SHUTOFF VALVE, SOLENOID VALVE
SVC SERVICE
SVW SERVICE WATER
SW SOUTHWEST
SWD SIDE WATER DEPTH
SWR SEWER
SWS SEAL WATER SOLENOID
SY SQUARE YARD
SYM SYMBOL
SYMM SYMMETRICAL
SYS SYSTEM
T TELEPHONE, TOP
TAN TANGENT
T&B TOP AND BOTTOM
TB TERMINAL BOX
TBE THREAD BOTH ENDS
TBM TEMPORARY BENCHMARK
TC TOP OF CURB
TDH TOTAL DYNAMIC HEAD
TEL TELESCOPING
TEMP TEMPERATURE, TEMPORARY
TERM TERMINAL
TH TEST HOLE
THK THICK, THICKNESS
THRD THREADED
TJ TIED JOINT
TOB TOP OF BANK
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOS TOP OF SLAB
TRANS TRANSFORMER, TRANSMITTER, TRANSFER
TS THICKENED SLUDGE
TV TELEVISION
TWP TOWNSHIP
TYP TYPICAL
UD UNDERDRAIN
UDM ULTRASONIC DENSITY METER
UG UNDERGROUND
UGE UNDERGROUND ELECTRIC
UNO UNLESS NOTED OTHERWISE
USGS UNITED STATES GEOLOGICAL SURVEY
UTC UNDERGROUND TELEPHONE CABLE
UTIL UTILITY
UV ULTRAVIOLET
V VALVE, VENT
VAC VACUUM
VB VALVE BOX
VC VERTICAL CURVE, VICTAULIC COUPLING
VCD VERTICAL CONTROL DAMPER
VCP VITRIFIED CLAY PIPE
VERT VERTICAL
VF VACUUM FILTER
VFD VARIABLE FREQUENCY DRIVE
VIB VIBRATION
VS VARIABLE SPEED
VTR VENT THROUGH ROOF
VV VENT VALVE
VVB VACUUM BREAKER
NOTE: THIS LEGEND IS FOR GENERAL REFERENCE. NOT ALL ABBREVIATIONS MAY BE USED IN THIS DESIGN, NOR IS THIS LEGEND COMPREHENSIVE. REFER TO INDIVIDUAL DRAWING LEGEND(S), IF ABBREVIATIONS ARE NOT LISTED. INDIVIDUAL DISCIPLINE STANDARD LEGENDS SUPERCEDE THIS GENERAL LEGEND, IF PROVIDED.
W WEST, WIDE, WATER
W/ WITH
WAS WASTE ACTIVATED SLUDGE
WD WOOD, WIDTH
WF WALL FITTING, WIDE FLANGE
WH WALL HYDRANT, WATER HEATER
WL WATER LEVEL
WM WATER METER, WATER MAIN
WO WINDOW OPENING
W/O WITHOUT
WP WATERPROOF, WORKING POINT
WR WASTE RECEPTACLE
WS WATERSTOP
WSP WELDED STEEL PIPE
WT WEIGHT
WTF WATER TREATMENT FACILITY
WTP WATER TREATMENT PLANT
WW WET WELL, WASH WATER
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WWTF WASTEWATER TREATMENT FACILITY
WWTP WASTEWATER TREATMENT PLANT
x BY,TIMES
XLHDPE CROSS LINKED HIGH-DENSITY POLYETHYLENE
YD YARD
YH YARD HYDRANT
YR YEAR
& AND
@ AT
DEFLECTION ANGLE
> GREATER THAN
< LESS THAN
# NUMBER
% PERCENT
MKW
AJM
JLH
MAB
MKW
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
A 09/2022 60% DRAWINGS AJM
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
MARK WORSHAM, State of Florida, Professional Engineer, License Number 66379
This item has been digitally signed and sealed by MARK WORSHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. (407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CERTIFICATE OF AUTH. 28386
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
GENERAL
SYMBOLS AND LEGENDS
G04 04
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/3 /2
:0
A
M V
P ro je ct s\
W S
F L
\P ro j1
\0
.0
\0
D e si g n \D ra w in g s\
S h e e ts \G
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
CB
PIPE DIA <24"
PIPE DIA >24"
Y
T
S
10"
4"
CATCH BASIN
MANHOLE
DRAINAGE COURSE OR FLOW LINE
EXISTING GROUND CONTOUR
FINISH GRADE CONTOUR
BANK OR SLOPE LINES
TEST OR BORE HOLE AND NUMBER
SURVEY LINE WITH PI, PT, OR POT
EXISTING
GENERAL LAYOUT YARD PIPING
NON-CONNECTING PIPING
CONSTRUCTION EASEMENT
EASEMENT
RIGHT-OF-WAY LINE
PERMANENT EASEMENT
TEMPORARY EASEMENT
UTILITY EASEMENT
SURVEY/SECTION LINE
WATER LINE (ABOVE GRADE)
ELECTRICAL LINE (UNDERGROUND)
OVERHEAD POWER
TELEPHONE/POWER POLE W/ GUY ANCHOR
FIRE HYDRANT
YARD HYDRANT
STREET LIGHT POLE
TRAFFIC SIGNAL
TRAFFIC SIGN
STOPSIGN
HEDGE, BRUSH, SHRUBS, WOODS
DECIDUOUS TREE AND TRUNK DIAMETER
CONIFEROUS TREE AND TRUNK DIAMETER
SWAMP
INSULATION (RIGID)
INSULATION (BATT)
ALUMINUM
BAR GRATING
(LINES IN DIRECTION OF SPAN)
STEEL
CHECKERED PLATE
RIPRAP
WOOD, STUDS, BEAMS, JOISTS, ETC
WOOD, SHEATHING,
PANELING, DECKING, ETC
CUT STONE OR SAND FILL, GROUT,
MORTAR, AND PLASTER
CONCRETE MASONRY UNITS (CMU)
BRICK, COMMON
BRICK, FACE
CONCRETE
ROCK
GRANULAR FILL
(CRUSHED ROCK OR GRAVEL)
EARTH OR GRADE
FUTURE
PROPOSED
UNDERGROUND
PROPOSED
ALUMINUM SULFATE - (ALUM)
ARGON
BLENDED WATER
CARBON SLURRY
ACETYLENE
CHLORINE GAS
CHLORINE LIQUID
CHLORINE SOLUTION
DISTILLED WATER
FERRIC CHLORIDE
FERRIC SULFATE
FIRE PROTECTION WATER SYSTEM
FLUORIDE
FUEL OIL RETURN
FUEL OIL SUPPLY
FUEL OIL VENT
HYDROGEN
HELIUM
HYDROGEN PEROXIDE
PHOSPHORIC ACID
HEATING SYSTEM WATER RETURN
HEATING SYSTEM WATER SUPPLY
HOT WATER (POTABLE)
HOT WATER CIRCULATING
INSTRUMENT AIR
POTASSIUM PERMANGANATE
LIME
LP GAS (PROPANE)
NITROGEN
SODIUM HYDROXIDE
SODIUM HYPOCHLORITE
AMMONIA GAS NITROUS OXIDE
OXYGEN
OZONE
OVERFLOW
POLYMER SOLUTION
CIVIL LEGEND
MATERIALS LEGEND
NOTE: THIS LEGEND IS FOR GENERAL REFERENCE. NOT ALL SYMBOLS, PROCESSES, MATERIALS, OR FITTINGS MAY BE USED IN THIS DESIGN, NOR IS THIS LEGEND COMPREHENSIVE.
REFER TO INDIVIDUAL DRAWING LEGEND(S), IF SYMBOLS ARE NOT LISTED. INDIVIDUAL DISCIPLINE STANDARD LEGENDS SUPERCEDE THIS GENERAL LEGEND, IF PROVIDED.
0'-2"
CALLOUT
PIPE DIA <24"
PIPE DIA >24"
NEW
CE
PE
TE
UE
E
G GAS LINE
OHP
TELEPHONE LINES (OVERHEAD)T
PROPERTY LINEP/L
R/W
TELEPHONE LINES (UNDERGROUND)T
WATER LINE (BELOW GRADE)
W
W
EXISTING
CHAIN LINK
WOOD
SILT
CENTERLINE
EXISTING PIPING
PROPOSED PIPING
PROPOSED PIPING (UNDERGROUND)
FUTURE PIPING
AIR (COMPRESSED)
STRUCTURES
FENCING
CHEMICAL RESISTANT ACID WASTE
CHEMICAL RESISTANT ACID WASTE VENT
COLD WATER
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CARBON DIOXIDE GAS
CARBON DIOXIDE SOLUTION
CHILLED WATER RETURN
CHILLED WATER SUPPLY
AMMONIA SOLUTION NON-POTABLE WATER
NON-POTABLE HOT WATER
GAS (NATURAL)
SUMP PUMP DISCHARGE
POTABLE WATER
GENERAL DRAFTING LEGEND PIPING SYSTEMS LEGEND
A
ALUM
AR
CRW
CRV
CW
ACET
C
Cl (G)
Cl (L)
Cl (S)
BW
CDWR
CDWS
CO2 (G)
CO2 (S)
CWR
CWS
AMM (G)
AMM (S)
FL
FOS
H
NaOCl
NaOH
NO
FOR
HP
IA
He
HW
LIME
N
NPW
NPHW
FOV
G
DW
FeCl
F
FeS
HWC
HWR
HWS
PD
PG
PERM
POLY
OF
OZ
OX
PA
PW
SCALE:
DETAIL TITLE
SCALE
X
ENLARGED PLAN
OR DETAIL
SEE DRAWING
0 #'#'
SCALE:
X
SECTION TITLE
SCALE
GRAPHIC SCALES
NORTH ARROW
SECTION CUT
DETAIL CALLOUT
DETAIL NUMBER
DRAWING NUMBER
SECTION LETTER
DRAWING NUMBER
DETAIL NUMBER
DRAWING NUMBER
SECTION LETTER
DRAWING NUMBER
CALLOUT
EQUIPMENT OR STRUCTURE
REPRESENTATION W/ CALLOUT
EXISTING EQUIPMENT, FACILITY,
PROCESS OR STRUCTURE
TO BE DEMOLISHED
GENERAL LABEL
PLAN DIMENSION
WL EL 0.00 WATER LEVEL LABEL
#'#' 0 #"
REFRIGERANT
SODIUM HEXAMETAPHOSPHATE
(PHOSPHATE)
STORM DRAIN
SODA ASH
SANITARY SEWER
SLUDGE GAS
VENT
SILICA
VACUUM
WATER
RF
SA
SG
VAC
SAN
SI
W
SP
ST
V
RAW WATERRAW
TH-# B#
ASPHALT
CO
SIZE
Q
S
S
AT
DT
S S
F
S
T
P
M
FM
BLIND FLANGE
CAP OR PLUG
CLEANOUT
CROSS
DIAPHRAGM SEAL
BEND
BEND DOWN
BEND UP
HOSE CONNECTION
QUICK COUPLING
REDUCER
RUPTURE DISK
WYE
WYE STRAINER
WYE STRAINER
W/ BLOWOFF
DRAIN OR BELL-UP
CALIBRATING
COLUMN
UNION
WALL SLEEVE
AUTOMATIC DRAIN TRAP
DRIP TRAP
DUPLEX
STRAINEREXPANSION COMPENSATOR
INLINE
FILTER
FLEXIBLE HOSE OR TUBING
FLEXIBLE CONNECTOR
HOSE REEL
INJECTOR, EDUCTOR,
BLENDER
PIPE GUIDE
ORIFICE PLATE
SEDIMENT TRAP
STRAINER
SUCTION
DIFFUSER
PIPE
DIFFUSER
SURGE CHAMBER
VENT
SCREENED
VENT
PRESSURE GAUGE
W/SNUBBER
SIGHT FLOW INDICATOR TEMPERATURE
INDICATOR
THERMOMETER
ELECTROMAGNETIC/
ULTRASONIC FLOWMETER
PITOT
TUBE
ROTAMETER
TURBINE OR
PROPELLOR
FLOWMETER
SET STOP
METER
VENTURI
FLOW METER VERTICAL MIXER
SIGHT GLASS
CENTRIFUGE
CHANNEL DIFFUSER
PUMP
SLUICE GATE
SLIDE GATE
STOP PLATE
BAR SCREEN
EXPANSION TANK
PIPING ACCESSORIES LEGEND
TEE
TEE LINE DOWN
TEE LINE UP
TRAP
S
MISCELLANEOUS
EQUIPMENT LEGEND
FM
STATIC MIXER
EXPANSION JOINT
E
P O
M
A
VPINCH VALVE
PLUG VALVE, ECCENTRIC
PLUG VALVE, NON-ECCENTRIC
BUTTERFLY VALVE
GATE VALVE
BALL VALVE
GLOBE VALVE
CHECK VALVE
3 WAY VALVE
4 WAY VALVE
ANGLE VALVE
CHLORINE INSTITUTE VALVE
DIAPHRAGM VALVE
THROTTLING VALVE
FLAME ARRESTER VALVE
BACKWATER VALVE
INLINE PRESSURE RELIEF VALVE
PRESSURE REGULATING VALVE
PRESSURE SUSTAINING OR
MAINTAINING VALVE
VACUUM BREAKER
THERMAL SHUTOFF VALVE
EXPLOSION RELIEF VALVE
HOSE FAUCET
HOSE FAUCET W/VACUUM BREAKER
HOSE VALVE W/HOSE NIPPLE
BACKFLOW PREVENTER
SAFETY RELIEF VALVE
VACUUM RELIEF CHECK VALVE
PRESSURE VACUUM
RELIEF VALVE
ELECTRIC
FLOAT
DIAPHRAGM
AIR/OIL TANDEM
MOTOR
AIR
ACTUATOR LEGENDVALVE LEGEND
S SOLENOID
H HAND
CHECK VALVE
KNIFE GATE VALVE
AIR RELEASE VALVE
MKW
AJM
JLH
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
A 09/2022 60% DRAWINGS AJM
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
MARK WORSHAM, State of Florida, Professional Engineer, License Number 66379
This item has been digitally signed and sealed by MARK WORSHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. (407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CERTIFICATE OF AUTH. 28386
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
GENERAL
GENERAL CONSTRUCTION NOTES
G05 05
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/5 /2
:4
A
M V
P ro je ct s\
W S
F L
\P ro j1
\0
.0
\0
D e si g n \D ra w in g s\
S h e e ts \G
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
GENERAL CONSTRUCTION NOTES
ALL WORK AND REQUIREMENTS FROM THE NOTES IN THIS PAGE SHALL BE A REQUIREMENT OF THE CONTRACT
AND EXECUTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO ORANGE COUNTY.
1. THE NORTHEAST WRF IS LOCATED AT 701 WEST MCCORMICK ROAD, APOPKA, FLORIDA.
2. ALL UTILITIES FACILITIES CONSTRUCTION CONNECTING TO THE ORANGE COUNTY UTILITIES SYSTEM SHALL CONFORM TO THE ORANGE COUNTY UTILITIES STANDARDS AND CONSTRUCTION SPECIFICATIONS MANUAL, AND BE ONE OF THE APPROVED PRODUCTS LISTED IN APPENDIX 'A' OF THE MANUAL.
3. COORDINATION AND COMMUNICATIONS WITH ORANGE COUNTY SHALL BE MADE THROUGH THE ORANGE COUNTY UTILITIES CONSTRUCTION DIVISION R.P.R. CONTACT AND THE OCU DISPATCH DURING EMERGENCIES, AND THE CONTRACTOR SHALL IMMEDIATELY NOTIFY ORANGE COUNTY UTILITIES DISPATCH (EMERGENCY
ONLY) IN THE EVENT OF UTILITY MAIN BREAK OR DAMAGE AT (407) 836-2777.
4. THE ORANGE COUNTY UTILITIES CONSTRUCTION DIVISION SHALL BE NOTIFIED AT LEAST SEVEN (7) DAYS PRIOR TO ANY CONSTRUCTION ACTIVITY, OR PRIOR TO ANY ACTIVITY REQUIRING THE PRESENCE OF OR AN ACTION BY UTILITIES STAFF SUCH AS SCHEDULING VALVE OPERATION, PRESSURE TESTING, PIPE CONNECTION, PUMP STATION OPERATIONS OR SHUTDOWNS, ETC. CONTRACTOR SHALL SUBMIT REQUEST ON
A C.A.R. FORM.
5. ORANGE COUNTY UTILITIES DEPARTMENT TELEPHONE NUMBERS:
ORANGE COUNTY UTILITIES DISPATCH 407-836-2777
ORANGE COUNTY UTILITIES CONSTRUCTION DIVISION 407-254-9798
ORANGE COUNTY UTILITIES WATER RECLAMATION DIVISION 407-254-9680
ORANGE COUNTY UTILITIES WATER DIVISION 407-254-9850
ORANGE COUNTY UTILITIES ENGINEERING DIVISION 407-254-9900
6. WATER, WASTEWATER AND RECLAIMED WATER VALVES, PUMP STATIONS OR OTHER UTILITY INFRASTRUCTURE ARE TO BE OPERATED ONLY BY ORANGE COUNTY UTILITIES PERSONNEL. ALL NEW VALVES BEING INSTALLED ARE TO REMAIN CLOSED DURING CONSTRUCTION AND ONLY OPERATED UNDER SUPERVISION OF ORANGE
COUNTY UTILITIES PERSONNEL.
7. ALL EXISTING WATER MAIN, FORCE MAINS, GRAVITY PIPES AND OTHER UTILITY FACILITIES WITHIN THE LIMITS OF THE PROJECT SHALL BE SUPPORTED AND PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. WHERE STORM DRAINAGE PIPING OR STRUCTURES ARE DAMAGED, THE CONTRACTOR SHALL REPAIR OR REPLACE AT
NO ADDITIONAL COST TO THE OWNER.
8. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN EXCAVATING IN PROXIMITY OF WATER MAINS, WASTEWATER FORCE MAINS, GRAVITY MAINS, AND RECLAIMED WATER MAIN. WATER MAINS, FORCE MAINS, GRAVITY MAIN, AND RECLAIMED WATER MAIN LOCATIONS SHOWN ON THE PLANS ARE NOT EXACT OR GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING EXISTING UTILITY LOCATIONS.
9. LOCATIONS OF EXISTING UTILITIES AS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTENCE AND LOCATION OF ALL ABOVEGROUND AND UNDERGROUND UTILITIES. CONTRACTOR SHALL CONTACT UTILITY OWNERS, INCLUDING FIBER OPTICS COMPANIES, AT LEAST SEVEN (7) DAYS PRIOR TO CONSTRUCTION AND A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. EXTREME CAUTION SHALL BE EXERCISED IN AREAS OF FIBER OPTICS, GAS MAINS AND ELECTRICAL CABLES AND CONDUITS.
10. CONTRACTOR SHALL COORDINATE WITH ALL OTHER UTILITY OWNERS FOR RESOLUTION OF CONFLICTS.
CONTRACTOR SHALL HAVE 48 HOURS TO DETERMINE THE RESOLUTION OF ANY UNKNOWN OR UNFORESEEN CONFLICTS. COSTS INCURRED SHALL BE BORNE BY THE UTILITY OWNER AND/OR CONTRACTOR AND NO CLAIMS MAY BE MADE AGAINST ORANGE COUNTY OR THE ENGINEER FOR THESE CONFLICTS. NO ADDITIONAL
COMPENSATION SHALL BE MADE FOR THE PERIOD OF TIME TO RESOLVE ANY CONFLICTS.
11. CONTRACTOR SHALL SUPPORT & PROTECT ALL EXISTING UTILITIES. CONTRACTOR SHALL CONTACT UTILITY OWNERS FOR LOCATION OF ALL EXISTING FACILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH UTILITY OWNERS AND BE RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT FOR
UTILITY POLES AND ALL OTHER UTILITIES DURING CONSTRUCTION.
12. THE UTILITIES IMPROVEMENTS AND ADJUSTMENTS SHOWN ON THESE DRAWINGS ARE INTENDED TO MAINTAIN THE INTEGRITY OF THE ORANGE COUNTY WATER, WASTEWATER, AND RECLAIMED WATER SYSTEMS. THE DRAWINGS DO NOT INCLUDE WORK PERFORMED ON, OR FOR UTILITY SYSTEMS OWNED BY OTHERS, UNLESS
STATED OTHERWISE ON THE DRAWINGS.
13. INSTALLATION, FLUSHING, AND PRESSURE AND LEAK TESTING SHALL BE PERFORMED BY THE CONTRACTOR IN ACCORDANCE WITH AWWA C600 FOR DUCTILE IRON WATER PIPELINES AND AWWA C605 FOR PVC WATER PIPELINES. FLUSHING, HYDROSTATIC TESTING, AND DISINFECTING SHALL CONFORM TO APPLICABLE SECTIONS OF THE ORANGE COUNTY STANDARDS AND CONSTRUCTION SPECIFICATIONS AND AWWA C651. FITTINGS AND MINOR REPLACEMENT SEGMENTS REQUIRED TO MAKE CONNECTIONS TO EXISTING WATER LINES SHALL BE THOROUGHLY DISINFECTED BY SWABBING THE ENTIRE INTERIOR WITH A MINIMUM 5% CHLORINE SOLUTION PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT, MATERIALS, AND MANPOWER TO ACCOMPLISH THESE OPERATIONS. AUTHORIZED ORANGE COUNTY UTILITIES PERSONNEL SHALL BE PRESENT DURING THE TEST. COORDINATE WITH ORANGE COUNTY UTILITIES INSPECTOR AT LEAST SEVEN
(7) DAYS PRIOR TO START THIS WORK.
14. ALL EXISTING AND NEW OCU WATER AND SEWER VALVES, VALVE BOXES, AND MANHOLES SHALL BE PROTECTED AND ADJUSTED TO FINISHED GRADE WHETHER SHOWN OR NOT. VALVE AND VALVE BOXES SHALL REMAIN ACCESSIBLE AT ALL TIMES. ANY VALVES THAT MIGHT BE COVERED DURING CONSTRUCTION SHALL BE MARKED WITH A MARKER (GREEN FOR SEWER, BLUE FOR WATER, AND PURPLE FOR RECLAIMED WATER MAIN), A MINIMUM OF FOUR (4) FEET BELOW GRADE. ALL NEW VALVES UNDER CONSTRUCTION ARE
TO REMAIN CLOSED DURING CONSTRUCTION.
15. ALL BURIED PIPELINES 4-INCHES TO 12-INCHES IN DIAMETER SHALL BE DUCTILE IRON AND CONFORM TO AWWA C150/C151. PIPES SHALL BE CEMENT LINED FOR W2 (RECLAIMED WATER) AND PROTECTO 401 COATED FOR PROCESS WASTEWATER. PVC PIPE AND FITTINGS UNDER 4-INCHES WILL BE SCHEDULE 80
CONFORMING TO ASTM D1784 AND D1785.
16. ALL PIPE, PIPE FITTINGS AND APPURTENANCES INSTALLED UNDER THIS PROJECT WILL BE COLOR CODED OR MARKED IN ACCORDANCE WITH SUBPARAGRAPH 62-555.320 (21) (B) 3, FAS, USING BLUE AS A
PREDOMINANT COLOR FOR WATER; GREEN FOR WASTEWATER; PURPLE FOR RECLAIMED WATER.
17. PIPE LENGTHS SHOWN ON PLANS ARE APPROXIMATE. ACTUAL LENGTHS ARE TO BE DETERMINED DURING
CONSTRUCTION.
18. ALL MAINS SHALL BE CONSTRUCTED AS SHOWN ON THE PLANS. PIPING SHALL BE LAID WITH A MINIMUM COVER OF 36 INCHES BELOW FINISHED GRADE FOR MAINS SIZED 12-INCHES AND BELOW, AND A MINIMUM COVER OF 48 INCHES FOR MAINS SIZED 16-INCHES AND GREATER, WHERE IT IS NOT OTHERWISE SPECIFIED ON PLANS OR DIRECTED BY THE ENGINEER. FOR PVC PIPE, NO HORIZONTAL/ VERTICAL PIPE OR JOINT DEFLECTION SHALL BE ALLOWED. CONTRACTOR SHALL USE FITTINGS TO OBTAIN REQUIRED CLEARANCES. ON DUCTILE IRON PIPE, CONTRACTOR SHALL NOT EXCEED 75% OF THE MANUFACTURER'S RECOMMENDATION FOR
PIPE DEFLECTION. OTHERWISE USE FITTINGS TO OBTAIN REQUIRED CLEARANCES.
19. KEEP VALVES ON ALL WET TAPS CLOSED UNTIL CLEARED BY FDEP. DO NOT CONNECT ANY PROPOSED
WATER MAIN TO ANY EXISTING WATER MAIN UNLESS CLEARED BY FDEP.
20. ALL CONNECTIONS TO EXISTING MAINS SHALL BE MADE BY THE CONTRACTOR ONLY AFTER THE PROPOSED CONNECTION PROCEDURE AND WORK SCHEDULE HAVE BEEN REVIEWED AND ACCEPTED BY THE OWNER. THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION SUBMITTAL (SHOP DRAWING) OUTLINING THE PROCEDURE AND SCHEDULE. WATER MAINS SHALL NOT BE PLACED IN SERVICE UNTIL CLEARANCE IS RECEIVED FROM FDEP.
21. INSTALL AIR RELEASE VALVES (ARV) AT ALL HIGH POINTS IN THE SYSTEM WHERE AIR CAN ACCUMULATE.
AIR RELEASE VALVES AND APPURTENANCES SHALL BE COLOR CODED FOR WATER.
22. THE ELEVATIONS SHOWN ARE BASED ON NAVD 1988 DATUM.
23. WHERE REQUIRED, AT NO ADDITIONAL COST TO THE COUNTY, THE CONTRACTOR SHALL USE TEMPORARY SHEETING OR TRENCH BOXES TO MINIMIZE THE SIZE OF EXCAVATIONS AND PROTECT EXISTING ROADWAYS, UTILITIES AND OTHER FACILITIES. OR AS NEEDED TO REMAIN WITHIN THE LIMITS OF CONSTRUCTION.
CONTRACTOR TO COMPLY WITH OSHA TRENCH SAFETY REQUIREMENTS AT ALL TIMES.
24. CONTRACTOR TO PROVIDE DETAILED AS-BUILT DRAWINGS OF ALL UTILITIES UNCOVERED IN TRENCHES. THE AS-BUILT SHALL RECORD LOCATION, SIZE, TYPE, ELEVATION AND OWNER OF ALL UTILITY FACILITIES
UNCOVERED.
25. WATER PIPE SHALL BE STAMPED BY THE NATIONAL SANITATION FOUNDATION (NSF) FOR POTABLE WATER USE. PIPING MATERIAL SPECIFICATIONS COVERING POTABLE WATER PIPES, JOINTING AND PACKING MATERIALS, INTERNAL COATING AND LININGS, FITTINGS, SPECIALS AND APPURTENANCES SHALL BE IN ACCORDANCE WITH THE CORRESPONDING AWWA STANDARDS AND CONFORM TO NSF REQUIREMENTS, AS MAY
BE APPLICABLE. ANY PIPE, PIPE FITTING, SOLDER, AND FLUX SHALL BE LEAD-FREE.
26. ALL MAIN REPAIRS TO BE COMPLETED IMMEDIATELY BY THE CONTRACTOR, AT THE CONTRACTOR'S COST. IF THE MAIN IS NOT REPAIRED IN A TIMELY MANNER, AS DETERMINED BY THE ENGINEER, ORANGE COUNTY UTILITIES PERSONNEL MAY REPAIR THE MAIN AND THE CONTRACTOR WILL BE CHARGED FOR
REPAIRS.
27. CONTRACTOR SHALL COORDINATE WITH ALL OTHER UTILITY OWNERS FOR THE RESOLUTION OF CONFLICTS.
ANY COST INCURRED SHALL BE BORNE BY THE UTILITY OWNER OR CONTRACTOR AND NO CLAIMS MAY BE
MADE AGAINST ORANGE COUNTY FOR THESE CONFLICTS.
28. O.C.U. SHALL OPERATE ALL EXISTING AND NEW VALVES CONNECTED TO ACTIVE SYSTEMS SUBMITTAL OF A
C.A.R. FORM.33.
29. EXISTING UTILITIES AND STRUCTURES (UNDERGROUND, SURFACE, OR OVERHEAD) ARE INDICATED ONLY TO THE EXTENT THAT SUCH INFORMATION WAS KNOWN, OR MADE AVAILABLE TO, OR DISCOVERED BY THE ENGINEER IN PREPARING THE DRAWINGS. THE LOCATIONS, CONFIGURATIONS, AND ELEVATIONS OF SUBSURFACE FACILITIES AND UTILITIES ARE APPROXIMATE, AND NOT ALL UTILITIES AND FACILITIES MAY BE INDICATED. OVERHEAD UTILITIES ARE NOT INDICATED IN ARCHITECTURAL ELEVATIONS, PROFILE OR SECTION DRAWINGS. THE ENGINEERING INVESTIGATIONS, LOCATION, AND DESIGNATION OF SUBSURFACE UTILITIES INDICATED IN THESE CONTRACT DOCUMENTS HAS BEEN PERFORMED TO QUALITY LEVEL C IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING PRINCIPLES AND PRACTICES AS OUTLINED IN ASCE STANDARD AND GUIDELINE BULLETIN CI/ASCE 38-02 UNLESS OTHERWISE DESIGNATED. WHERE SUCH ACTIVITIES HAVE BEEN TO A HIGHER LEVEL OF QUALITY, THE HIGHER QUALITY LEVEL FOR THE AFFECTED AREAS IS
INDICATED IN THE CONTRACT DOCUMENTS.
30. "SCREENED" (LIGHT) DELINEATION INDICATED ON THE DRAWINGS DENOTES EXISTING FACILITIES. "SCREENED" INFORMATION WAS TAKEN FROM EXISTING CONSTRUCTION DRAWINGS AND DATA, IS FOR REFERENCE ONLY, AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO THE ORDERING OF MATERIALS AND BEGINNING OF CONSTRUCTION. "BOLD" DELINEATION IS NEW WORK TO BE CONSTRUCTED UNDER THIS
CONTRACT.
31. CONTRACTOR'S STAGING, PARKING AND MATERIAL STORAGE SHALL BE COORDINATED WITH OCU. PROVIDING
ADDITIONAL STORAGE OR PARKING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
32. CALL BEFORE YOU DIG. CONTRACTOR SHALL VERIFY PRECISE LOCATIONS AND ELEVATIONS OF ALL UTILITIES AND STRUCTURES, WHETHER INDICATED ON THE DRAWINGS OR NOT, IN THE FIELD IN ADVANCE OF EXCAVATING, BY CONTACTING ALL UTILITIES AND OTHER AGENCIES, AND BY PROSPECTING. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, DEMOLITION, RECONSTRUCTION, AND RECONNECTION OF EXISTING FACILITIES AS REQUIRED TO COMPLETE THE WORK. IF REQUIRED AFTER FIELD VERIFICATION, CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO DETERMINE ANY NECESSARY MODIFICATIONS TO PROPOSED NEW
WORK.
33. BEFORE CONSTRUCTION IS STARTED, CONTRACTOR SHALL COORDINATE WITH THE OWNER OF EACH UTILITY AND DEFINE THE REQUIREMENTS AND METHODS TO ACCOMMODATE THE PROTECTION, TEMPORARY SUPPORT, ADJUSTMENT, OR RELOCATION OF ANY UTILITIES AFFECTED BY THE PROPOSED NEW WORK.
34. CONTRACTOR SHALL COMPLY WITH THE GOVERNING AGENCY NPDES CONSTRUCTION REQUIREMENTS, AND SHALL PROVIDE APPROPRIATE MITIGATION MEASURES OR PROTECTION AND RESTORATION AT ALL LOCATIONS AS REQUIRED BY THEIR OPERATIONS, AND AS DIRECTED BY ENGINEER. SPECIAL CONSTRUCTION REQUIREMENTS, TEMPORARY PROTECTIVE FENCING OR BARRICADES, SHEETING, SHORING, EROSION PROTECTION, AND SURFACE RESTORATION AT CERTAIN LOCATIONS ARE INDICATED ON THE DRAWINGS TO
BRING CONTRACTOR'S ATTENTION TO SENSITIVE AREAS.
35. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL PROPERTY CORNER MARKERS.
PROPERTY CORNER MARKERS DAMAGED BY CONSTRUCTION ACTIVITIES SHALL BE REESTABLISHED BY A
PROFESSIONAL SURVEYOR LICENSED IN THE STATE OF FLORIDA.
36. CONTRACTOR SHALL PROTECT AND MAINTAIN ALL EXISTING TREES, SHRUBS, AND PLANTS UNLESS
OTHERWISE NOTED.
37. CONTRACTOR SHALL INSTALL ALL PIPELINES, PAVING, WALKWAYS, AND CURB AND GUTTER AT A UNIFORM
GRADE BETWEEN ELEVATIONS DEPICTED ON THE DRAWINGS.
38. FOR ALL SITE GRADING, SMOOTH PARABOLIC TRANSITIONS SHALL BE MADE BETWEEN CHANGES IN SLOPE.
PARABOLIC ROUNDING SHALL APPLY TO ALL CUT AND FILL SECTIONS.
39. FINISHED GRADE ELEVATION AT THE BUILDING FACE, WHERE NOT ADJACENT TO PAVEMENT, SHALL BE APPROXIMATELY 6 INCHES BELOW FINISHED FLOOR ELEVATION UNLESS OTHERWISE NOTED. FINISHED GRADE ELEVATION ADJACENT TO BASINS SHALL BE APPROXIMATE AS INDICATED BY CONTOURS, OR AS REQUIRED
TO MEET STAIR LANDINGS.
40. THE CONTRACTOR'S OPERATIONS SHALL CONFORM TO THE RULES AND REGULATIONS OF THE STATE
CONSTRUCTION SAFETY ORDERS PERTAINING TO EXCAVATION AND TRENCHING.
41. RESTRAINED JOINTS SHALL BE PROVIDED FOR ALL BURIED PIPING.
42. THE DRAWINGS INDICATE TYPES OF PIPE SUPPORT SYSTEMS AT VARIOUS LOCATIONS. HOWEVER, All PIPE SUPPORTS, HANGERS, BRACKETS, INSERTS OR BRACES ARE NOT SHOWN. CONTRACTOR SHALL REFER TO THE SPECIFICATIONS AND PROVIDE A COMPLETE SUPPORT SYSTEM AS REQUIRED.51. THE TERM "PROPOSED" AS INDICATED ON THE DRAWINGS MEANS THE ITEM IS DESIGNED OR PLANNED TO BE PROVIDED BY OWNER OR OTHERS SEPARATE FROM THIS CONTRACT. THE TERM "FUTURE" AS INDICATED ON THE DRAWINGS REFERS TO THE ENGINEER'S INTERPRETATION OF THE ITEM FOR THE FUTURE, BASED ON AVAILABLE
INFORMATION.
43. STRUCTURES SUCH AS CURBS AND GUTTERS, CONCRETE AND ASPHALT DRIVES AND WALKWAYS, PAVING BRICKS, FENCING, RETAINING WALLS, ETC, CROSSED BY THE PIPELINE ARE NOT ALL INDICATED IN PROFILE.
CONTRACTOR SHALL RESTORE ANY EXISTING STRUCTURES THAT ARE DISTURBED, DAMAGED OR REMOVED BY
CONSTRUCTION.
44. CONTRACTOR SHALL REPLACE EXISTING PIPE CULVERTS THAT ARE REMOVED TO INSTALL THE NEW PIPELINE WITH NEW PIPE CULVERTS OF THE SAME SIZE, MATERIAL AND CONSTRUCTION AT THE SAME LOCATION AND INVERT ELEVATION AS THOSE THAT WERE REMOVED, AND SHAPE THE DITCH TO DRAIN WITH THE REPLACED CULVERT. CONTRACTOR SHALL PROVIDE ANY TEMPORARY CULVERTS THAT MAY BE REQUIRED FOR CONTRACTOR'S OPERATIONS. CONTRACTOR SHALL COORDINATE REMOVAL AND REPLACEMENT OF ANY
CULVERTS WITHIN PUBLIC RIGHT-OF-WAY WITH THE REGULATING AGENCY.
45. HORIZONTAL STATIONING ALONG THE PIPELINE ALIGNMENT IS FOR LEVEL LINE MEASUREMENT AND FOR PAYMENT OF THE PIPELINES. CONTRACTOR SHALL PROVIDE THE ACTUAL PIPE LENGTH TO BE DETERMINED
BY THE SLOPE OR CURVE ON WHICH THE PIPE IS INSTALLED.
46. CONTRACTOR SHALL FIELD VERIFY PRECISE LOCATION, ELEVATION, AND ARRANGEMENT OF CONNECTIONS OF NEW PIPELINES WITH EXISTING PIPELINES BASED ON FIELD CONDITIONS, INCLUDING EXPOSING EXISTING PIPING PRIOR TO FABRICATING NEW PIPING. CONTRACTOR SHALL PROVIDE FITTINGS, ADAPTERS, SOLID SLEEVE CLOSURES, AND HARNESSED MECHANICAL COUPLING; ROTATE FITTINGS; DEFLECT JOINTS; AND MODIFY EXISTING PIPING AS APPLICABLE AND AS REQUIRED TO MAKE CONNECTIONS, INCLUDING ADJUSTMENTS FOR ANY OFFSETS IN CENTERLINE ELEVATIONS BETWEEN PIPELINES. CONTRACTOR SHALL PROVIDE TEMPORARY PLUG WITH FACTORY OUTLET SIZED AS REQUIRED FOR CONTRACTOR'S TESTING AND DISINFECTION WORK BEFORE MAKING CONNECTION, WHEN APPLICABLE. CONTRACTOR SHALL COORDINATE
MAKING EACH CONNECTION WITH THE OWNER.
MKW
AJM
JLH
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
A 09/2022 60% DRAWINGS AJM
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
MARK WORSHAM, State of Florida, Professional Engineer, License Number 66379
This item has been digitally signed and sealed by MARK WORSHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. (407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CERTIFICATE OF AUTH. 28386
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
CIVIL
SITE PLAN / DEMOLITION PLAN
C01 06
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/2
/2
:5
A M
V P ro je ct s\
W S
F L
\P ro j1
\0
.0
\0
D e si g n \D ra w in g s\
S h e e ts
\C .d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
MKW
AJM
JLH
MAB
MKW
0 200'100'
EFFLUENT FILTERS
EFFLUENT DISC FILTERS
CLARIFIER NO.3
CLARIFIER NO.4
FUEL STORAGE
TANKS
CLARIFIER NO.2
CLARIFIER NO.1
AERATION BASIN
TRAIN 2
AERATION BASIN TRAIN 1
TRAIN 1 AND 2
INFLUENT METER VAULT
ANOXIC BASINS
GENERATOR BUILDING
GROUND STORAGE
TANK
STORAGE YARD
OPERATIONS AND
MAINTENANCE BUILDING
PRELIMINARY TREATMENT
STRUCTURE
GRIT PUMP WELL
BNR TRAIN 3
INFLUENT METER
VAULT
BNR TRAIN 3
ANAEROBIC BASINS
SLUDGE
HOLDING TANKS
SLUDGE
PRESS BUILDING
AIR COMPRESSOR
BUILDING
GRAVITY BELT
THICKENER
SODIUM HYPOCHLORITE
STORAGE AND FEED
CHLORINE
CONTACT BASIN
EFFLUENT
PUMP STATION
BLOWER BUILDING
REAERATION
BASINS
PROJECT AREAS
KEY
CONTRACTOR
STAGING AREA
CONTRACTOR TEMPORARY
TRAILER LOCATION
1. DEMOLISH AND REPLACE CLARIFIER
MECHANISMS, SCUM TROUGH, DRIVE,
WALKWAYS AND PLATFORM; INSTALL
WEIR WASHING SYSTEM (TYP x4).
NOTES
SV
SV
SV
S S
8 D R
8 DR
W
8 W1
8 W
36 ML
S
S S
S
A H
P
A H
P
30 ML
30 ML
M
L M
L
8 W2
W
W
S
S
6 DR
W
A S
C
LW8 W1
W
W
4 DR
8 DR
8 SS
4 SL
S
S
12 SS
T
S
W
W
6 DR
W
14 FM
12 SS
36 CLW
3 CLS 3 CLS
12 SS
14 FM
16 RAS
8 DR
12 FM
F M
6 W2 8 W1 8 W1
30 ML
M
L
16 RAS
30 ML
30 M L
36 ML
12 SS12 SS12 SS
8 D R
D
R -2
D
R -2
W
-2
36 SE
D
R -2
-1
/4 W
-2
6 SL
36 W2-1
S
A
36 FE
S
A 2 S
A
8 SL
12 DR
S
L
W
-2
6 S L
8W2-2
12 D R
6 S S6 S
S
R
A S
W
-2
4 W2
S
C
S
E
12 SS
R
E J
C
LS
2 W2-2
A
H P
P
S
2 PS
2 AHP
2 AHP
16 RAS
MH E
99.5
99.5
S
A
20 W2-1
4 SL
S
L
4 SS
2 W2-2
4x12
RDCR
4DR
2W2-2
1A H
P
D
R -2
C.O.
6 SL
6 SL
6 SL
4 SL
4 SL
12 DR
4 W2
8 SL
4 SL
8 ALP
6 SL
S
L
8 ALP 6 SL6 SL
12 DR-212 DR-2
4 SL
4 SL
4 W2
S
L
O
V E
R
FL
O W
(T Y
P
4 W2-2
S
L
W
-2
W
-2
6-V-21
(TYP)
8x8x6
TEE (TYP)
W
-2
6 DR6 DR
INLET
2" PW21 1/4" SA-2
2" PW21 1/4" SA-2
FM
M
S
W
S S
W
W
H F
H F
H F
H F
H F
H F
H F
H F
P R
W
M M
M M
HF
HF
HF
M
HF
M
SHEET NO.:
REVISION:
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
A 09/2022 60% DRAWINGS AJM
B 03/2023 90% DRAWINGS AJM
C 06/2024 100% ISSUED FOR BID AJM
MARK WORSHAM, State of Florida, Professional Engineer, License Number 66379
This item has been digitally signed and sealed by MARK WORSHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. (407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CERTIFICATE OF AUTH. 28386
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
CIVIL
YARD PIPING PLAN
C02 07
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/6
/2
:3
A
M V
P ro je ct s\
W S
F L
\P ro j1
\0
.0
\0
D e si g n \D ra w in g s\
S h e e ts \C
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
MKW
AJM
JLH
MAB
MKW
0 60'30'
4" WET TAP ON
EXISTING W2 PIPING, RMJ.
ALSO RESTRAIN ANY
EXISTING PIPE JOINTS
WITHIN 10' OF CONNECTION
4" DI TAPPING GATE VALVE,
RMJ W/ VALVE BOX
4" DI 22.5° BEND,
RMJ (TYP x2)
4" DI PIPE, RMJ
4" DI 90° BEND,
RMJ (TYP x2)
WEIR WASH SYSTEM PUMPS 3 AND 4
(SEE DWG PM06)
WEIR WASH SYSTEM PUMPS 1 AND 2
(SEE DWG PM06)
2" SCH 80 PVC
SOLVENT WELDED
2" SCH 80 PVC RISER
W/ BRONZE BALL VALVE
FOR CONNECTION TO WEIR
WASHING SYSTEM
2" SCH 80 PVC RISER
W/ BRONZE BALL VALVE
FOR CONNECTION TO WEIR
WASHING SYSTEM
2" SCH 80 PVC
SOLVENT WELDED
2" SCH 80 PVC RISER
W/ BRONZE BALL VALVE
FOR CONNECTION TO WEIR
WASHING SYSTEM
(SEE DWG PM02 FOR CONTINUATION)
2" SCH 80 PVC
SOLVENT WELDED
2" SCH 80 PVC RISER
W/ BRONZE BALL VALVE
FOR CONNECTION TO WEIR
WASHING SYSTEM
(SEE DWG PM02 FOR CONTINUATION)
2" SCH 80 PVC
SOLVENT WELDED
INSTALL 6"x6"x4" TEE
ON EXISTING W2 PIPING.
RMJ. ALSO RESTRAIN ANY
EXISTING PIPE JOINTS
WITHIN 10' OF CONNECTION
4" DI GATE VALVE, RMJ
W/ VALVE BOX
4" DI PIPE, RMJ
WAS FLOW METER
ASSEMBLY
(SEE DWG PM05)
EXISTING 12" W2
6" DI WAS
ASSEMBLY
PIPING, RMJ
CONNECTION TO
8" SLUDGE PIPING
(SEE INSET THIS
SHEET)
EXISTING 8"
WAS PIPING
8"DI TEE, RMJ
REMOVE 8"x4" REDUCER
REMOVE 4" COUPLER
4" DI SCUM PIPING
REMOVE 10' OF
4" SCUM PIPING
DEMOLITION
PROPOSED
EXISTING 8"
WAS PIPING
8"DI TEE, RMJ
4" DI SCUM PIPING
8"x6" DI REDUER, RMJ
6" DI TEE, RMJ
6" DI PIPING TO WAS ASSEMBLY
(SEE THIS DWG FOR CONTINUATION)
6"x4" DI
REDUCER, RMJ
4" RESTRAINED
JOINT COUPLING
AREA TO BE
RENOVATED
6 2
SINK
6 66
2SINK
NOTE #1:
THIS IS AN EXISTING BUILDING THAT WAS PERMITTED IN 1997 AS A
MIXED USE BUILDING. THIS RENOVATION IS IN THE AREA OF THE
BUILDING THAT WAS PERMITTED AS GROUP B, BUSINESS UNDER THE
STANDARD BUILDING CODE. EQUIVALENT OCCUPANCY
CLASSIFICATION UNDER CURRENT FLORIDA BUILDING CODE IS
BUSINESS GROUP B (SECTION 304).
NOTE #2:
THE WORK DESCRIBED HEREIN IS FOR THE RENOVATION OF THE
EXISTING LABORATORY. THE LABORATORY IS 544 SQ. FT., OR 5.4% OF
THE BUSINESS AREA OF 9,987 SQ. FT.
NOTE #3:
THE WORK DESCRIBED HEREIN DOES NOT INVOLVE ANY CHANGE OF
OCCUPANCY, TRAVEL PATTERNS OR TRAVEL DISTANCE.
NOTE #4:
THE WORK DESCRIBED HEREIN SHALL BE CLASSIFIED AS A LEVEL 2
ALTERATION UNDER FLORIDA BUILDING CODE, EXISTING BUILDINGS
(603.1). ALL WORK SHALL COMPLY WITH CURRENT EDITION OF THE
FLORIDA BUILDING CODE (801.3).
BUILDING CODE NOTES
1 REMOVE SUSPENDED CEILING, LIGHT FIXTURES, GRILLES, ETC.
DEMOLITION LEGEND:
2 REMOVE ALL CASEWORK, COUNTERTOPS, AND SINKS.
3 REMOVE FUME HOODS AND APPLIANCES.
4 REMOVE CERAMIC TILE FLOORING.
5 REMOVE NON-BEARING DRYWALL PARTITION.
6 REMOVE ALL FURNITURE AND STORE OR SALVAGE AT OWNER'S
DIRECTION.
7 REMOVE EXISTING EYEWASH AND PROVIDE NEW EYEWASH - SEE
PLUMBING DRAWINGS.
8 REMOVE A/C DUCTWORK, GRILLES AND DIFFUSERS - SEE HVAC
PLANS.
9 EXISTING FIRST AID KIT TO BE RETAINED.
10 EXISTING MARBLE TABLE TO BE RETAINED.
11 REMOVE EXISTING WINDOW BLINDS
12 EQUIPMENT ON THIS WALL TO BE REMOVED
SHEET NO.
REVISION:
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
TEC
AEN
TEC
TEC
TEC
The Villages, FL 32162
Thomas E. Cunningham
1692 Duffy Loop Architect
407.595.1496 TecArch2015@outlook.com
B 03/2023 90% DRAWINGS TEC
THOMAS E. CUNNINGHAM, State of Florida, Architect, AR14116
This item has been digitally signed and sealed by THOMAS E. CUNNINGHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
A 09/2022 60% DRAWINGS TEC
C 06/2024 100% ISSUED FOR BID TEC
(407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
ARCHITECTURAL
KEY PLAN, DEMOLITION PLAN, AND NOTES
A01 08
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/1
/2
:0 A
M A
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
SCALE:
KEY PLAN
1/16"=1'-0"SCALE:
KEY PLAN
1/16"=1'-0"
SCALE:
DEMOLITION PLAN
3/8"=1'-0"
C-1C-2C-5
C-6
C-7
C-8
C-9
C-10
C-11 C-13
C-15
C-16
C-17
C-19 C-18
C-3C-4
C-12 C-14 6 4 4
C-7 C-8 C-9C-5 C-10 C-11
OPEN
FILLER
PANEL
C-6
FILLER
PANEL
C-20
C-11 C-12 C-13 C-14
E X
IS
T
IN
G
W
IN
D O
W
E X
IS
T
IN
G
W
IN
D O
W
2 4 4
ELEVATION 3
E X
IS
T
IN
G
D O
O R
1 1
C-15 C-16 C-17
ELEVATION 4
C-1 C-2 C-3 C-4 C-5
E X
IS
T
IN
G
D O
O R
C-20
C-18
C-19
ELEVATION 7
E X
IS
T
IN
G
D O
O R
NOTE: EXISTING
SHELVING UNITS
TO REMAIN
NOTE: EXISTING
EQUIPMENT ON
THIS WALL TO BE
REMOVED
24" x 48"
SUSPENDED
ACOUSTICAL
TILE CEILING
@ 10'-0" A.F.F.
NOTE:
SEE
ELECTRICAL
DRAWINGS
FOR LIGHTING
SEE HVAC
DRAWINGS
FOR GRILLES
AND
DIFFUSERS
1 PAINTED DRYWALL
LEGEND:
2 CERAMIC TILE BASE
3 EXISTING REFRIGERATOR -
TO BE REMOVED AND PUT BACK IN
PLACE UPON COMPLETION OF
CONSTRUCTION
4 EXISTING FILE CABINET -
TO BE REMOVED AND PUT BACK IN
PLACE UPON COMPLETION OF
CONSTRUCTION
5 FIRST AID CABINET TO REMAIN
6 EXISTING MARBLE TABLE -
TO BE REMOVED AND PUT BACK IN
PLACE UPON COMPLETION OF
CONSTRUCTION
SEE SHEET A03 FOR LABORATORY
CASEWORK SCHEDULEC-?
NOTE:
REUSE EXISTING FIRE EXTINGUISHER
AND RELOCATE PER FIRE MARSHALL.
IF THE EXISTING IS UNSERVICEABLE,
PROVIDE A NEW ONE OF
COMPARABLE QUANTITY.
SHEET NO.
REVISION:
DRAWING NO.
SCALE:
PROJECT NO.:
DESCRIPTIONDATEREV
BA DC FE HG JI LK M ON QP
LINE IS 1" AT
FULL SIZE
Designed
Checked Reviewed Approved
Drawn
BY
TEC
AEN
TEC
TEC
TEC
The Villages, FL 32162
Thomas E. Cunningham
1692 Duffy Loop Architect
407.595.1496 TecArch2015@outlook.com
B 03/2023 90% DRAWINGS TEC
THOMAS E. CUNNINGHAM, State of Florida, Architect, AR14116
This item has been digitally signed and sealed by THOMAS E. CUNNINGHAM on the date indicated here.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
A 09/2022 60% DRAWINGS TEC
C 06/2024 100% ISSUED FOR BID TEC
(407) 679-5358
WINTER SPRINGS, FL 32708
1016 SPRING VILLAS PT.
CHA CONSULTING, INC.
P a re n t S h e e t
S e t:
R e v/
P lo t b y:
In d iv id u a l F ile P a th
R e v o n
ARCHITECTURAL
FLOOR PLAN, CEILING PLAN, AND INTERIOR ELEVATIONS
A02 09
CNOTED
_O
C _N
W R
F L ab M
IL
LE
R , J
A Y
/1
/2
:0 A
M A
.d w g
ORANGE COUNTY NORTHERN WATER RECLAMATION FACILITY
CLARIFIERS #1-#4, WAS, METER, AND LAB IMPROVEMENTS 071402
SCALE:
FLOOR PLAN
3/8"=1'-0"
SCALE:
ELEVATION 1
1/4"=1'-0"
SCALE:
ELEVATION 2
1/4"=1'-0"
SCALE:
ELEVATION 3
1/4"=1'-0"
SCALE:
ELEVATION 4
1/4"=1'-0"
SCALE:
ELEVATION 5
1/4"=1'-0"
SCALE:
ELEVATION 6
1/4"=1'-0"
SCALE:
ELEVATION 7
1/4"=1'-0"
SCALE:
ELEVATION 8
1/4"=1'-0"
SCALE:
REFLECTED CEILING PLAN
1/4"=1'-0"
C-1
LABORATORY CASEWORK SCHEDULE
MARK DESCRIPTION SIZE
BASE DRAWER UNIT 24"W x 22"D x 32"H
C-2 BASE DOOR UNIT 18"W x 22"D x 32"H
C-3 BASE CABINET WITH SINK 42"W x 22"D x 32"H
C-4
C-5
C-6
C-7
C-8 BASE DOOR UNIT 18"W x 22"D x 32"H
BASE CORNER UNIT 32"W x 22"D x 32"H x 14"
BASE DOOR UNIT 18"W x 22"D x 32"H
C-9 BASE DOOR AND DRAWER UNIT 42"W x 22"D x 32"H
C-10 42"W x 22"D x 32"H
C-11
C-12
C-13
CATALOG NO.
D30C322224
G23C322218
G07C322242
BASE DOOR UNIT 18"W x 22"D x 32"H G23C322218
G15C322214
G23C322218
G23C322218
BASE CABINET 42"W x 22"D x 32"H G07C322242
BASE DOOR AND DRAWER UNIT
E42C322242
E43C322242L
32"W x 22"D x 32"H x 14" G15C322214BASE CORNER UNIT WITH SINK
BASE DRAWER UNIT 18"W x 22"D x 29"H
BASE DRAWER UNIT 18"W x 22"D x 29"HC-14
BASE CABINET 42"W x 22"D x 29"H
D81C292218
D81C292218
STORAGE CABINET W/ SWINGING DOORS42"W x 16"D x 84"HC-15 S50C841642
STORAGE CABINET W/ SWINGING DOORS42"W x 16"D x 84"HC-16 S50C841642
STORAGE CABINET W/ SWINGING DOORS30"W x 16"D x 84"HC-17 S50C841630
STORAGE CABINET W/ SWINGING DOORSC-18 S50C842248
STORAGE CABINET W/ SWINGING DOORSC-19
48"W x 22"D x 84"H
S50C84224848"W x 22"D x 84"H
NOTE: CATALOG NUMBERS ARE KEWAUNEE RESEARCH COLLECTION
AND ARE GIVEN TO ESTABLISH A BASIS OF DESIGN.
EPOXY DRYING RACK (PEGBOARD)C-20 X-020017-BK32"W x 1"D x 30"H
D81C292218
1. INSTALL NEW SUSPENDED ACOUSTICAL TILE CEILING (SEE
SPECIFICATIONS). COORDINATE WITH ELECTRICAL AND HVAC
WORK.
FINISH NOTES
2. PATCH EXISTING DRYWALL TO MATCH EXISTING FINISH. ENTIRE
WALLS TO BE PAINTED.
3. INSTALL NEW SEAMLESS FLOORING (SEE SPECIFICATIONS)
2' -1
0"
4"
1 2"
2'-6"
3"
EPOXY
CONTERTOP
CERAMIC
TILE BASE
METAL CABINET
4"
1 2"
2'-6"
3"
EPOXY
CONTERTOP
CERAMIC
TILE BASE
METAL CABINET
1. INSTALL NEW…
This is the start of the file's text. The full file is on GovTribe.