The document is a comprehensive set of architectural and electrical design drawings for the Orange County Clerk of Courts Ocoee Branch Security Upgrade project located at 475 Story Rd #15 in Ocoee, Florida. The project involves a security enhancement renovation of approximately 3,860 square feet within an existing county service center, with key modifications including relocating waiting area seating, installing a new weapons screening area, implementing security cameras, adding panic buttons, and upgrading exterior doors with enhanced access control. The project is seeking bids with a response deadline of December 13, 2022, and has an estimated project cost of $350,000.00.
The contract includes several additive bid alternate options such as installing a walk-through metal detector, x-ray checkpoint security screening equipment, wire mesh barriers at clerk stations, additional security cameras, and converting exterior doors to controlled access points. The renovation will be completed while maintaining building operations, with all construction work performed after business hours. The design documents specify compliance with Florida Building Codes (7th Edition, 2020), National Electrical Code (2017), and Fire Prevention Code, and the project is classified as a Level 2 alteration for a sprinklered, primarily business occupancy building with a total occupant load of 397 persons.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Y23-738-RC_Apopka_Security_Specifications.pdf | ||
| Y23-738-RC_Apopka_Security_Drawings.pdf | ||
| Y23-738-RC_Ocoee_Security_Specifications.pdf | ||
| Y23-738-RC.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SGM
ELECTRICAL ENGINEER
935 LAKE BALDWIN LANE,
ORLANDO, FL 32814
(407) 767-5188
CONTACT: JUSTIN MUNDELL
PROJECT NUMBER:
ORANGE COUNTY MAYOR
COMMISSIONER DISTRICT 1
COMMISSIONER DISTRICT 2
COMMISSIONER DISTRICT 3
COMMISSIONER DISTRICT 4
COMMISSIONER DISTRICT 5
COMMISSIONER DISTRICT 6
ORANGE COUNTY PROJECT MANAGER:
05/04/2022
RE-BID / PERMIT ISSUE SET 2
CHRISTINE MOORE
NICOLE H. WILSON
MAYRA URIBE
MARIBEL GOMEZ CORDERO
EMILY BONILLA
VICTORIA P. SIPLIN
HONORABLE JERRY DEMINGS
JOHN AMES
CLERK OF COURTS
18268
ORANGE COUNTY
475 STORY RD #15
OCOEE, FL 34761
SECURITY UPGRADE
OCOEE SECURITY
ARCHITECTURAL DESIGN
COLLABORATIVE
ARCHITECT
945 N. PENNSYLVANIA AVENUE
WINTER PARK, FLORIDA 32789
(407) 629-1188
CONTACT: AL COOPER
STRUCTURAL ENGINEER
1214 EAST CONCORD STREET,
ORLANDO, FL 32803
(407) 377-7227
CONTACT: LAURA BARBERO-BUFFA
SECURITY CONSULTANT
3408 HILLCREST DRIVE
WACO, TX 76708
(512) 451-5445
CONTACT: TONY CHOJNOWSKI
OCCUPANCY LOAD CALCULATIONS BY OCCUPANCY CLASSIFICATION
LEVEL - EXISTING ONE STORY BUILDING MAIN FLOOR
GROSS FLOOR AREA
(SQ.FT)
FLOOR AREA IN SQ.FT. PER
OCCUPANT GROSS/NET
OCCUPANCY LOAD
(PERSONS)
BUSINESS AREAS 21896 150 146
ASSEMBLY 1811 15 121
STORAGE 3131 300 11
COURTROOM 1316 40 33
GYM (A-3 ASSEMBLY) 603 50 13
TOTAL SQUARE FOOTAGE AND OCCUPANCY LOAD 28757 324
PROJECT ADDRESS: 475 STORY RD #15
OCOEE, FL 34761
PROJECT NAME: ORANGE COUNTY
Ocoee Security
SECURITY UPGRADE
PROJECT DESCRIPTION: OCOEE SECURITY
AREA OF ALTERATION: 3,860 SQ.FT
VIEWNUMBER
SHEETNUMBER
TYP.
X
X-XXX
XX
X
VIEWNUMBER
SHEETNUMBER
TYP.
FABRIC WRAPPED PANEL
ACOUSTICAL TILE
CARPET
PLASTER WITH LATH
SECTION INDICATIONS
ELEVATION INDICATIONS
BRICK/CONCRETE BLOCK
FINISHED WOOD
GLASS
STONE
GYPSUM BOARD
INSULATION (LOOSE OR BATT)
INSULATION (RIGID)
GLASS (LARGE SCALE)
METAL
PLYWOOD
WOOD (FINISH)
WOOD (CONTINUOUS)
WOOD (BLOCKING)
EARTH OR NATURAL GROUND
SAND OR GROUT
POROUS FILL (GRAVEL)
INTERRUPTED MEMBER
BRICK
STONE
CONCRETE MASONRY UNIT
CONCRETE
NON-FERROUS ALUMINUM
PLASTER/ STUCCO
SURFACES
SHEET NOTE
ALIGN WITH ESTABLISHED
CONSTRUCTION
ROW ON ELEVATION SHEET
NORTH ARROW
REFLECTED CEILING
AND GRID
MAIN RUNNER
ACOUSTICAL CEILING
GYPSUM BOARD SOFFIT
ELEVATION NUMBER
SHEET WHERE SHOWN
VIEWNUMBER
SHEETNUMBER
TYP.
SECTION NUMBER
SHEET WHERE SHOWN
DIRECTION OF ELEVATION
DIRECTION OF SECTION
PLANE OF SECTION
SHEET WHERE SHOWN
DIRECTION OF ELEVATION
ELEVATION NUMBER
DETAIL AREA
DESCRIPTION OF
SIMILAR OR
OPPOSITE
SHEET WHERE
SHOWN
DETAIL NUMBER
HEIGHT REFERENCE
HEIGHT REFERENCE LEVEL
REVISION AREA
REVISION DELTA No
OFFICE ROOM NAME
ROOM NUMBER
XXXX
X'-XX"
N.T.S.
IMAGE TAKEN FROM GOOGLEMAPS.COM
ALL WORK FOR THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES:
GRAPHIC SYMBOLS
VICINITY MAPCODE DATA
INDEX
ALIGN
EXPS EXPOSE(D)
REINF REINFORCE(D)(ING)
F S
T G
U
V
W
J
I
H
CABINET
AND AIR CONDITIONING
REINFORCED CONCRETE
REINFORCED GYPSUM
REINFORCED PLASTER
WTRPRF
WT
W/O
WDW
WD
WC
W/
VIF
VERT
VEH
UNO
UTIL
UNDRLAY
TYP
T&G
TRTD
TRANS
TRAF
TLT
THK
SYS
SUSP
SURF
STRUCT
STRFR
STL
STD
SST
SIM
SHORG
SGL
SF
SECUR
SCR
RO
RM
RFG
RESIL
JAN
INFILTR
INT
INTLK
INSUL
INSTRUM
INFO
HVAC
HORIZ
HM
HDWE
HDWD
HD
GYP
GR
GL
GFRP
GFRG
GFRC
GA
FUT
FURN
FLR
FXTR
FXD
FRMG
FR
FPLC
FLDG
FIN
FHC
FE&C
FE
FD
FAB
EXT
WATERPROOFING
WEIGHT
WITHOUT
WINDOW
WOOD
WATER CLOSET
WITH
VERIFY IN FIELD
VERTICAL
VEHICLE
UNLESS NOTED
UTILITY
UNDERLAYMENT
TYPICAL
TONGUE AND GROOVE
TREATED
TRANSPARENT
TRAFFIC
TOILET
THICK
SYSTEM(S)
SUSPENDED
SURFACE
STRUCTURAL
STOREFRONT
STEEL
STANDARD
STAINLESS STEEL
SIMILAR
SHORING
SINGLE
SQUARE FEET
SECURITY
SCRIBE
ROOM
ROOFING
RESILIENT
JANITOR
INFILTRATION
INTERIOR
INTERLOCK(ING)
INSULATION
INSTRUMENT(ATION)
INFORMATION
HEATING, VENTILATING,
HORIZONTAL
HOLLOW METAL
HARDWARE
HARDWOOD
HEAD
GYPSUM
GRAD(E)(ING)
GLASS
GLASS FIBER
GLASS FIBER
GLASS FIBER
GAUGE
FUTURE
FURNITURE
FLOOR(ING)
FIXTURE
FIXED
FRAMING
FIRE RAT(ING)(ED)
FIREPLACE
FOLDING
FINISH
FIRE HOSE CABINET
FIRE EXTINGUISHER AND
FIRE EXTINGUISHER
FLOOR DRAIN
FABRICATION
EXTERIOR
A
K
L
MB
C
N
O
D
P
RE
RESIS
REQD
REFR
REFL
REF
RECPT
RECES
RDR
PRTECN
PLYWD
PLSTC
PLAS
PLAM
PREFAB
PREFIN
PORT
POLYST
PNL
PBD
PEDTR
PTN
OPR
OPNG
OVHD
OVFL
ORNA
NTS
NO
NIC
MTD
MOT
MOIST
MLWK
MISC
MIN
MEZZ
MEMB
MET
MECH
MFR
MFD
MAX
LVR
LVLG
LT
LB
LAV
KIT
EXP JT
EXIST
EQUIP
ENTR
ENGR
EMBED
ELEC
ELAST
DWR
DSCON
DR
DN
DIV
DISP
DIM
DIFF
DIA
DF
DET
DES
DEPT
DBL
CMU
COV
CONTR
CONT
CONSTR
CONC
COILG
COATG
CLG
CER
CEM
CPT
CAB
BU
BRDLM
BLKG
BD
BOLLD
BLDG
AVG
AUTO
ARCH
APPL
ANOD
ANNUNC
ALT
AL
AFF
ACOUS
ACCES
RESIST(ANT)(IVE)
REQUIRED
REFRIGERATOR
REFLECTED
REFER(ENCE)
RECEPTACLE
RECESSED
READER
PROTECTION
PLYWOOD
PLASTIC
PLASTER
PLASTIC LAMINATE
PREFABRICATED
PREFINISHED
PORTABLE
POLYSTYRENE
PANEL
PARTICLE BOARD
PEDESTRIAN
PARTITION
OPERABLE
OPENING(S)
OVERHEAD
OVERFLOW
ORNAMENTAL
NOT TO SCALE
NUMBER
NOT IN CONTRACT
MOUNTED
MOTOR(IZED)
MOISTURE
MILLWORK
MISCELLANEOUS
MINIMUM
MEZZANINE
MEMBRANE
METAL
MECHANICAL
MANUFACTURER
MANUFACTURED
MAXIMUM
LOUVER
LEVELING
LIGHT
BRITISH POUND
POUND
LAVATORY
KITCHEN
EXPANSION JOINT
EXISTING
EQUIPMENT
EQUAL
ENTRANCE
ENGINEER(ED)
EMBEDD(ED)(ING)
ELECTRICAL
ELASTOMERIC
DRAWER
DISCONNECT
DOOR
DOLLAR (US CURRENCY)
DOWN
DIVISION
DISPENSER
DIMENSION
DIFFUSER
DIAMETER
DRINKING FOUNTAIN
DETAIL
DESIGN(ED)
DEPARTMENT
DOUBLE
COVER
CONTRACT(OR)
CONTINUOUS(ATION)
CONSTRUCTION
CONCRETE
COILING
COATING
CEILING
CERAMIC
CEMENT(ITIOUS)
CARPET
CABINET
BUILT UP
BROADLOOM
BLOCKING
BOARD
BOLLARD
BUILDING
AND
AVERAGE
AUTOMATIC
ARCHITECT(URAL)
APPLIANCE
ANODIZED
ANNUNCIATOR
ALTERNATE
ALUMINUM
ABOVE FINISHED FLOOR
ACOUSTIC(AL)
ACCESSORY
FWC FABRIC WALL COVERING
FUTUREFUT
AHJ
PjM PROJECT MANAGER
4' X 4' FLUORESCENT LIGHT
FIXTURE
2' X 2' FLUORESCENT LIGHT
FIXTURE
UNDER CABINET FLUORESCENT
FIXTURE
FLUORESCENT STRIP FIXTURE
ARCHITECTURAL ABBREVIATIONS
AUTHORITY HAVING
JURISDICTION
CONCRETE MASONRY
UNIT
(CURRENCY)
OTHERWISE
PROJECT INFORMATION
LOCATION MAP
AS SHOWED
Ocoee Security
SECURITY UPGRADE
OCOEE, FL 34761
475 STORY RD #15
ORANGE COUNTY
18268
INDEX AND PROJECT INFORMATION
A00.00
AJC
04 AJCBID/PERMIT ISSUE SET 205/04/2022
03 NRABID/PERMIT ISSUE SET11/11/19
02 NRA90% CD'S09/26/19
AJCNRA60% CD'S08/01/1901
RE-BID / PERMIT ISSUE SET 2
05/04/2022
NRA
N.T.S.
IMAGE TAKEN FROM GOOGLEMAPS.COM
BUILDING CODE: FLORIDA BUILDING CODE - BUILDING
7th Edition (2020)
FLORIDA BUILDING CODE - EXISTING BUILDING
7th Edition (2020)
FLORIDA BUILDING CODE - ACCESSIBILITY
7th Edition (2020)
FLORIDA BUILDING CODE - MECHANICAL
7th Edition (2020)
FLORIDA BUILDING CODE - PLUMBING
7th Edition (2020)
NFPA 70: NATIONAL ELECTRICAL CODE- 2017
FIRE PREVENTION CODE: FLORIDA FIRE PREVENTION CODE- 7th Edition 2020
BASED ON: NFPA 101 - 2018 LIFE SAFETY CODE
WITH FLORIDA AMENDMENTS AND NFPA 1 - 2018
FIRE CODE WITH FLORIDA AMENDMENTS
LEVEL OF ALTERATION: LEVEL 2
TYPE OF CONSTRUCTION: II
SPRINKLERED SPRINKLERED
OCCUPANT LOAD 324
REFER TO SHEET A00.50 FOR LIFE SAFETY PLAN
ORANGE COUNTY OCOEE SERVICE CENTER
PROJECT LOCATION:
ORANGE COUNTY OCOEE SERVICE CENTER
Consultant ● Seal/Signature
Sheet Title:
Project Number
Scale
File Name
Drawn By
Checked ByAR
CH
ITE
CT
UR
E
PL
AN
NI
NG
IN
TE
RI
OR
D
ES
IG
N
SP
AC
E
PL
AN
NI
NG
Issue Date
Project Status
PR
IN
TE
D
ON
Client Information
ADCARCHITECTURAL DESIGN COLLABORATIVE
Architect ● Seal/Signature
Issue
Project Documents for:
Date Issue Description
Project:
Check By
945 N. PENNSYLVANIA AVENUE
WINTER PARK, FLORIDA 32789
OFFICE: (407) 629-1188
FAX: (407) 388-1220
WWW. ADCINTERNATIONAL.NET
OVERALL SCOPE OF WORK:
1. BRANCH SECURITY ENHANCEMENTS.
SCOPE OF WORK NOTES:
1. ALL EXISTING WAITING AREA SEATING WILL BE REUSED AND RELOCATED
TO ACCOMMODATE NEW WEAPON SCREENING AREA.
2. CONTRACTOR WILL PATCH AND REPAIR WALLS AND CEILINGS ADJACENT TO
CONSTRUCTION AS REQUIRED, INCLUDING PAINT AND FINISH TO MATCH
THE EXISTING WALL OR CEILING.
3. WORK THAT IS NOT STATED HEREIN NOR SHOWN IN THESE PLANS IS NOT
PART OF THE SCOPE OF WORK FOR THIS PROJECT.
4. ADDITIONAL WORK REQUIRED THAT WOULD ALTER THE PRESENTED SCOPE
OF WORK SHALL BE SUBJECT TO A REVISION OF THESE DOCUMENTS AND
TO BE REVIEWED BY THE BUILDING DEPARTMENT HAVING JURISDICTION.
1. THE BUILDING WILL REMAIN IN OPERATION DURING CONSTRUCTION.
2. ALL CONSTRUCTION WORK WILL BE PERFORMED AFTER BUSINESS HOURS.
NOTE TO CONTRACTOR
SCOPE OF WORK
STRUCTURAL
S5.001 GENERAL NOTE AND DETAILS
ELECTRICAL
E00.01 ELECTRICAL SYMBOLS LEGEND
E01.01A OVERALL DEMO PLAN - ELECTRICAL
E01.01B ENLARGED DEMO PLAN - ELECTRICAL
E01.01C ENLARGED DEMO PLAN - ELECTRICAL
E02.01A OVERALL CONSTRUCTION PLAN - ELECTRICAL
E02.01B ENLARGED CONSTRUCTION PLAN - ELECTRICAL
E02.01C ENLARGED CONSTRUCTION PLAN - ELECTRICAL
E07.01 ELECTRICAL SCHEDULES
RE-BID / PIS AJCNRA01/20/211
ARCHITECTURAL
COVER COVER
A00.00 INDEX AND PROJECT INFORMATION
A00.10 GENERAL NOTES
A00.11 GENERAL NOTES
A00.12 GENERAL NOTES
A00.13 RFI's A00.14 RFI's
A00.30 DOOR FRAME & HARDWARE SCHEDULES
A00.40 ACCESIBILITY DETAILS
A00.50 LIFE SAFETY PLAN
A01.00 EXISTING CONDITIONS
A01.01A DEMOLITION PLAN
A01.01B ENLARGED DEMOLITION PLAN
A01.01C ENLARGED DEMO PLANS
A02.01A CONSTRUCTION FLOOR PLAN
A02.01B ENLARGED CONSTRUCTION FLOOR PLAN
A02.01C ENLARGED CONSTRUCTION FLOOR PLANS
A04.01 PROPOSED REFLECTED CEILING PLAN
AutoCAD SHX Text
AutoCAD SHX Text
EQ
AutoCAD SHX Text
AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315
AutoCAD SHX Text
MEANS OF EGRESS REQUIREMENTS - PRIMARILY BUSINESS OCCUPANCY - SPRINKLERED
AutoCAD SHX Text
EXIT ACCESS TRAVEL DISTANCE:
AutoCAD SHX Text
300FT (WITH SPRINKLER SYSTEM) TABLE 1017.2
AutoCAD SHX Text
MAX. COMMON PATH OF EGRESS TRAVEL DISTANCE:
AutoCAD SHX Text
100FT (WITH SPRINKLER SYSTEM) TABLE 1006.2.1
AutoCAD SHX Text
MAX. DEAD END CORRIDOR: 50FT (WITH SPRINKLER SYSTEM) PER 1020.4
AutoCAD SHX Text 116 BREAK ROOM 95 Sq.Ft. ASSEMBLY @ 15 SQ.FT./OCC.
AutoCAD SHX Text 117 VESTIBULE 74 Sq.Ft. BUSINESS
AutoCAD SHX Text 117A SHOWER 112 Sq.Ft. BUSINESS
AutoCAD SHX Text 118 STORAGE 67 Sq.Ft. STORAGE @ 300 SQ.FT./OCC
AutoCAD SHX Text 119 BRIEFING ROOM 619 Sq.ft. BUSINESS
AutoCAD SHX Text 120 EVIDENCE ROOM 90 Sq.Ft. BUSINESS
AutoCAD SHX Text 121 SEARGENT OFFICE 116 Sq.Ft. BUSINESS
AutoCAD SHX Text 123 SEARGENT OFFICE 128 Sq.Ft. BUSINESS
AutoCAD SHX Text 115 COURT ROOM 1,316 Sq.Ft. COURTROOM @ 40 SQ.FT./OCC.
AutoCAD SHX Text 114 BALIFF'S OFFICE 159 Sq.Ft. BUSINESS
AutoCAD SHX Text 113 JURY ROOM 280 Sq.Ft. ASSEMBLY @ 15 SQ.FT./OCC.
AutoCAD SHX Text 112 COURT ADMIN. OFFICE 296 Sq.Ft. BUSINESS
AutoCAD SHX Text 110 SECRETARY 199 Sq.Ft. BUSINESS
AutoCAD SHX Text 108 JUDGE'S CHAMBER 361 Sq.Ft. BUSINESS
AutoCAD SHX Text 106 OFFICE 398 Sq.Ft. BUSINESS
AutoCAD SHX Text 107 OFFICE BIKE PATROL 392 Sq.Ft. BUSINESS
AutoCAD SHX Text 104A OFFICE 295 Sq.Ft. BUSINESS
AutoCAD SHX Text 104 OFFICE 207 Sq.Ft. BUSINESS
AutoCAD SHX Text 103 OFFICE 201 Sq.Ft. BUSINESS
AutoCAD SHX Text 102 DRESSING 44 Sq.Ft. BUSINESS
AutoCAD SHX Text 101D DIRECTORS OFFICE 128 Sq.Ft. BUSINESS
AutoCAD SHX Text 101C STORAGE VAULT 183 Sq.Ft. BUSINESS
AutoCAD SHX Text 101B STORAGE CASE FILING 311 Sq.Ft. BUSINESS
AutoCAD SHX Text 101A LOUNGE 224 Sq.Ft. ASSEMBLY @ 15 SQ.FT./OCC.
AutoCAD SHX Text 101 COURT RECORDS OFFICE 1,744 Sq.Ft. BUSINESS @ 150 SQ.FT./OCC. TYP.
AutoCAD SHX Text
ROOM SQUARE FOOTAGE OCCUPANCY CLASSIFICATION
AutoCAD SHX Text
AREA CALCULATIONS AND OCCUPANCY CLASSIFICATIONS BY FUNCTION/ROOM
AutoCAD SHX Text TOTAL: 28,757 Sq.Ft.
AutoCAD SHX Text 105 OFFICE 278 Sq.Ft. BUSINESS
AutoCAD SHX Text 124 LIEUTENANT OFFICE 122 Sq.Ft. BUSINESS
AutoCAD SHX Text 125 CAPTAINS OFFICE 167 Sq.Ft. BUSINESS
AutoCAD SHX Text 126 LIEUTENANT OFFICE 134 Sq.Ft. BUSINESS
AutoCAD SHX Text 127 SECRETARY 148 Sq.Ft. BUSINESS
AutoCAD SHX Text 128 OFFICE/COMPUTER 189 Sq.Ft. BUSINESS
AutoCAD SHX Text 129 RECEPTION 173 Sq.Ft. BUSINESS
AutoCAD SHX Text 132A TAXES & TAGS 496 Sq.Ft. BUSINESS
AutoCAD SHX Text 132B OFFICE 96 Sq.Ft. BUSINESS
AutoCAD SHX Text 132C STORAGE/LOUNGE 271 Sq.Ft. BUSINESS
AutoCAD SHX Text 132D STORAGE 109 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 133 SOCIAL SERVICE OFFICE 174 Sq.Ft. BUSINESS
AutoCAD SHX Text 133A OFFICE 116 Sq.Ft. BUSINESS
AutoCAD SHX Text 149 WAITING AREA 839 Sq.Ft. ASSEMBLY @ 15 SQ.FT./OCC.
AutoCAD SHX Text 149A INTERVIEW 108 Sq.Ft. BUSINESS
AutoCAD SHX Text 149B OFFICE 59 Sq.Ft. BUSINESS
AutoCAD SHX Text 149C STORAGE 35 Sq.Ft. STORAGE @ 300 SQ.FT./OCC
AutoCAD SHX Text 150 STORAGE 88 Sq.ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 151 PUBLIC DEFENSE OFFICE 85 Sq.Ft. BUSINESS
AutoCAD SHX Text 152 STORAGE 734 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 153 STORAGE 85 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 148 RECORDS OFFICE 432 Sq.Ft. BUSINESS
AutoCAD SHX Text 147 OPEN OFFICE 250 Sq.Ft. BUSINESS
AutoCAD SHX Text 146 OFFICE 129 Sq.Ft. BUSINESS
AutoCAD SHX Text 145 EXAM ROOM 143 Sq.Ft. BUSINESS
AutoCAD SHX Text 144 HEAD NURSES OFFICE 120 Sq.Ft. BUSINESS
AutoCAD SHX Text 143 DENTIST OFFICE 124 Sq.Ft. BUSINESS
AutoCAD SHX Text 141 EXAM ROOM 123 Sq.Ft. BUSINESS
AutoCAD SHX Text 142 LAB 124 Sq.Ft. BUSINESS
AutoCAD SHX Text 139B STORAGE/LOUNGE 120 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 139 EXAM ROOM 123 Sq.Ft. BUSINESS
AutoCAD SHX Text 138A DEPUTYS OFFICE 120 Sq.Ft. BUSINESS
AutoCAD SHX Text 138 OFFICE COMMUNITY POLICE 222 Sq.Ft. BUSINESS
AutoCAD SHX Text 137 EXAM ROOM 124 Sq.Ft. BUSINESS
AutoCAD SHX Text 136 OFFICE 236 Sq.Ft. BUSINESS
AutoCAD SHX Text 135 EXAM ROOM 113 Sq.Ft. BUSINESS
AutoCAD SHX Text 134A KITCHEN 109 Sq.Ft. ASSEMBLY @ 15 SQ.FT./OCC.
AutoCAD SHX Text 134 NURSES OFFICE 245 Sq.Ft. BUSINESS @ 150 SQ.FT./OCC. TYP.
AutoCAD SHX Text 140 NURSES OFFICE 365 Sq.Ft. BUSINESS
AutoCAD SHX Text 154 OFFICE 88 Sq.Ft. BUSINESS
AutoCAD SHX Text 199 CENTRAL CONCOURSE 5,867 Sq.Ft. BUSINESS
AutoCAD SHX Text 199A CORRIDOR 623 Sq.Ft. BUSINESS
AutoCAD SHX Text 199B CORRIDOR 303 Sq.Ft. BUSINESS
AutoCAD SHX Text 199D CORRIDOR 392 Sq.Ft. BUSINESS
AutoCAD SHX Text 199E CORRIDOR 736 Sq.Ft. BUSINESS
AutoCAD SHX Text C100A TELEPHONE 40 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text C100C TELEPHONE 96 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text J100A JANITOR 117 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text M100A MAINTENANCE 90 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text M100B MECHANICAL 591 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 147A TEACHING AREA 263 Sq.Ft. BUSINESS
AutoCAD SHX Text 130 GYM 603 Sq.Ft. ASSEMBLY A-3 @ 50 SQ.FT./OCC
AutoCAD SHX Text M100C MECHANICAL 715 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text R100A WOMENS 77 Sq.Ft. BUSINESS
AutoCAD SHX Text R100B TOILET 42 Sq.Ft. BUSINESS
AutoCAD SHX Text R100E WOMENS 218 Sq.Ft. BUSINESS
AutoCAD SHX Text R100F MENS 206 Sq.Ft. BUSINESS
AutoCAD SHX Text R100G TOILET 51 Sq.Ft. BUSINESS
AutoCAD SHX Text R100H TOILET 39 Sq.Ft. BUSINESS
AutoCAD SHX Text R100M TOILET 62 Sq.Ft. BUSINESS
AutoCAD SHX Text R100C MENS 77 Sq.Ft. BUSINESS
AutoCAD SHX Text R100D TOILET 90 Sq.Ft. BUSINESS
AutoCAD SHX Text R100I TOILET 48 Sq.Ft. BUSINESS
AutoCAD SHX Text R100J TOILET 46 Sq.Ft. BUSINESS
AutoCAD SHX Text R100K TOILET 40 Sq.Ft. BUSINESS
AutoCAD SHX Text R100L TOILET 46 Sq.Ft. BUSINESS
AutoCAD SHX Text C100B TELEPHONE 38 Sq.Ft. STORAGE @ 300 SQ.FT./OCC.
AutoCAD SHX Text 101E WAITING ROOM OFFICE 459 Sq.Ft. BUSINESS
AutoCAD SHX Text 117 STORAGE 206 Sq.Ft. STORAGE @ 300 SQ. FT./OCC.
AutoCAD SHX Text 133B OFFICE 120 Sq.Ft. BUSINESS
AutoCAD SHX Text 199C CORRIDOR 108 Sq.Ft. BUSINESS
AutoCAD SHX Text
- CORRIDOR 120 Sq.Ft. BUSINESS
AutoCAD SHX Text
- CORRIDOR 49 Sq.Ft. BUSINESS
AutoCAD SHX Text 122 CORRIDOR 60 Sq.Ft. BUSINESS
AutoCAD SHX Text 132 WAITING ROOM 264 Sq.Ft. ASSEMBLY @ 15 SQ.FT./OCC.
./A00.00 INDEX.DWG
./A00.00 INDEX.DWG
./A00.30 DOOR SCHEDULE.DWG
./A00.30 DOOR SCHEDULE.DWG
./A00.40 ACCESIBILITY DETAILS.DWG
./A00.40 ACCESIBILITY DETAILS.DWG
./A01.00 EXISTING CONDITIONS.DWG
./A01.00 EXISTING CONDITIONS.DWG
./A01.01A DEMOLITION PLAN.DWG
./A01.01A DEMOLITION PLAN.DWG
./A01.01B DEMOLITION PLAN - ENLARGED PLANS.DWG
./A01.01B DEMOLITION PLAN - ENLARGED PLANS.DWG
./A01.01C DEMOLITION PLAN - ENLARGED PLANS.DWG
./A01.01C DEMOLITION PLAN - ENLARGED PLANS.DWG
./A02.01A CONSTRUCTION PLAN.DWG
./A02.01A CONSTRUCTION PLAN.DWG
./A02.01B CONSTRUCTION PLAN - ENLARGED PLAN.DWG
./A02.01B CONSTRUCTION PLAN - ENLARGED PLAN.DWG
./A02.01C CONSTRUCTION PLAN - ENLARGED PLANS.DWG
./A02.01C CONSTRUCTION PLAN - ENLARGED PLANS.DWG
./A04.01 PROPOSED RCP.DWG
./A04.01 PROPOSED RCP.DWG
1.0 GENERAL NOTES & CONDITIONS GEN. NOTES & CONDITIONS (CONT.) CONSTRUCTION PLAN NOTES (CONT.)
2.0 CONSTRUCTION PLAN NOTES
3.0 REFLECTED CLG & MECH. SYS
Consultant ● Seal/Signature
Sheet Title:
Project Number
Scale
File Name
Drawn By
Checked ByAR
CH
ITE
CT
UR
E
PL
AN
NI
NG
IN
TE
RI
OR
D
ES
IG
N
SP
AC
E
PL
AN
NI
NG
Issue Date
Project Status
PR
IN
TE
D
ON
Client Information
ADCARCHITECTURAL DESIGN COLLABORATIVE
Architect ● Seal/Signature
Issue
Project Documents for:
Date Issue Description
Project:
Check By
945 N. PENNSYLVANIA AVENUE
WINTER PARK, FLORIDA 32789
OFFICE: (407) 629-1188
FAX: (407) 388-1220
WWW. ADCINTERNATIONAL.NET
GEN. NOTES & CONDITIONS (CONT.)
Ocoee Security
SECURITY UPGRADE
OCOEE, FL 34761
475 STORY RD #15
ORANGE COUNTY
A00.10
RE-BID / PERMIT ISSUE SET 2
05/04/2022
AutoCAD SHX Text
3.1 SCOPE: GC SHALL FURNISH AND INSTALL CONTINUOUS GRID SUSPENDED ACOUSTICAL TILE CEILING MATERIAL AS SPECIFIED AND AS INDICATED ON PLAN AND PROVIDE CUT OUTS AND OTHER PROVISIONS FOR OTHER TRADES AS REQUIRED. 3.2 CEILING GRID SYSTEM SHALL BE IN CONFORMANCE WITH ASTM C 635 AND WITH GENERAL PRACTICES AND APPLICABLE STATE AND LOCAL ORDINANCES. INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURERS RECOMENDATIONS AND ASTM C 636. 3.3 GC SHALL VERIFY CONFORMANCE WITH LOCAL AND STATE CODES AND BUILDING STANDARDS BEFORE SUBMITTING FINAL PRICING.
AutoCAD SHX Text
1.22 NOT USED
AutoCAD SHX Text
1.12 THE GC SHALL PREPARE, REVIEW, STAMP WITH APPROVAL AND SUBMIT, WITH REASONABLE PROMPTNESS AND IN ORDERLY SEQUENCE SO AS TO CAUSE NO DELAY IN THE WORK, SUBMITTALS REQUIRED BY THE CONTRACT DOCUMENTS, TO ARCHITECT FOR REVIEW. SUBMIT FIVE (5) COPIES. REQUIRED SUBMITTALS: SHOP DRAWINGS, PRODUCT AND SAMPLES AS REQUIRED IN INDIVIDUAL SECTIONS. SAMPLES: WHEN REQUIRED SUBMIT TWO (2). CONSTRUCTION SCHEDULE: LINEAR BAR CHART, TIME CONTROLS, SHOP DRAWINGS: PDF COPY AS BUILTS: HARD COPY.
AutoCAD SHX Text
1.2 UPON COMPLETION OF THE JOB, THE CONTRACTOR SHALL PROVIDE THE OWNER WITH: A. AS-BUILT PLANS. AS-BUILT PLANS. B. RELEASE OF LIENS FOR ALL SUB-CONTRACTORS. RELEASE OF LIENS FOR ALL SUB-CONTRACTORS. C. THE ORIGINAL BUILDING PERMIT PLANS WITH THE ORIGINAL THE ORIGINAL BUILDING PERMIT PLANS WITH THE ORIGINAL INSPECTOR'S SIGNATURES.
AutoCAD SHX Text
1.3 THE OWNER WILL NOT BE RESPONSIBLE FOR:
AutoCAD SHX Text
A. SECURITY OF MATERIALS OF WORK IN PLACE.
AutoCAD SHX Text
B. SEE ENGINEERING DRAWINGS FOR WORK RELATED TO THE
AutoCAD SHX Text
BUILDING SYSTEMS/MEPF.
AutoCAD SHX Text
C. WARRANTY REPAIRS.
AutoCAD SHX Text
D. WINDOW BREAKAGE DURING CONSTRUCTION.
AutoCAD SHX Text
E. WORK STOPPAGES DUE TO WORK INTERFERING WITH OTHER
AutoCAD SHX Text
TENANTS.
AutoCAD SHX Text
F. DELAYS DUE TO CHANGE ORDERS AND ARCHITECT-
AutoCAD SHX Text
CONTRACTOR PROBLEMS.
AutoCAD SHX Text
G. PAYMENT OF ANY DRAW WILL BE SUBJECT TO THE OWNER'S
AutoCAD SHX Text
REPRESENTATIVES AGREEING TO THE DEGREE OF COMPLETION.
AutoCAD SHX Text
TEN PERCENT (10%) OF EACH DRAW WILL BE HELD AS A RETAINER
AutoCAD SHX Text
UNTIL THE JOB IS COMPLETED, INCLUDING PUNCH LIST ITEMS,
AutoCAD SHX Text
RELEASES OF LIEN, AND ACCEPTANCE OF THE SPACE BY BOTH THE
AutoCAD SHX Text
TENANT AND OWNER.
AutoCAD SHX Text
1.4 THE CONTRACTOR WILL:
AutoCAD SHX Text
SECURE THE NECESSARY BUILDING PERMITS AND INSPECTIONS.
AutoCAD SHX Text
INDEMNIFY AND KEEP HARMLESS THE OWNER FROM ALL LOSSES,
AutoCAD SHX Text
DAMAGES, LIABILITIES, AND EXPENSES WHICH MAY ARISE OR BE CLAIMED
AutoCAD SHX Text
AGAINST THE LANDLORD AND BE IN FAVOR OF ANY PERSONS, FIRMS, OR
AutoCAD SHX Text
CORPORATIONS FOR ANY INJURIES OR DAMAGES TO THE PERSON OR
AutoCAD SHX Text
PROPERTY OF ANY PERSONS, FIRMS, OR CORPORATION CONSEQUENT
AutoCAD SHX Text
UPON OR ARISING FROM THE CONSTRUCTION, USE, OR OCCUPANCY OF
AutoCAD SHX Text
LEASED PREMISES BY THE CONTRACTOR OR CONSEQUENT UPON OR
AutoCAD SHX Text
ARISING FROM ANY ACTS, OMISSIONS, NEGLECT OR FAULT OF THE
AutoCAD SHX Text
CONTRACTOR , HIS AGENTS, SERVANTS, EMPLOYEES, LICENSEES,
AutoCAD SHX Text
VISITORS, CUSTOMERS, PATRONS, OR INVITEES, OR CONSEQUENT UPON
AutoCAD SHX Text
OR ARISING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH ANY
AutoCAD SHX Text
LAWS, STATUTES, ORDINANCES, CODES, OR REGULATIONS; THAT THE
AutoCAD SHX Text
OWNERS SHALL NOT BE LIABLE TO THE CONTRACTOR FOR DAMAGES,
AutoCAD SHX Text
LOSSES OR INJURIES TO THE PERSONS, FIRMS OR CORPORATIONS
AutoCAD SHX Text
EXCEPT WHEN SUCH INJURY, LOSS, OR DAMAGE RESULTS FROM
AutoCAD SHX Text
NEGLIGENCE OF THE OWNER, HIS AGENTS, OR EMPLOYEES, AND THAT
AutoCAD SHX Text
THE CONTRACTOR WILL IDEMNIFY AND KEEP HARMLESS THE OWNERS
AutoCAD SHX Text
AND BE IN FAVOR OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR ANY
AutoCAD SHX Text
INJURIES OR DAMAGES TO THE PERSON, OR THE PROPERTY OF ANY
AutoCAD SHX Text
PERSONS, FIRMS OR CORPORATIONS WHERE SAID INJURIES OR
AutoCAD SHX Text
DAMAGES AROSE ABOUT OR UPON THE LEASED PREMISES AS A RESULT
AutoCAD SHX Text
OF THE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES,
AutoCAD SHX Text
SERVANTS, LICENSES, VISITORS, CUSTOMERS, PATRONS, AND INVITEES.
AutoCAD SHX Text
ALL PERSONAL PROPERTY PLACED OR MOVED INTO OR OUT OF THE
AutoCAD SHX Text
BUILDING SHALL BE AT THE RISK OF THE CONTRACTOR OR THE OWNER
AutoCAD SHX Text
THEREFORE AND THE OWNERS SHALL NOT BE LIABLE TO THE CONTRACTOR
AutoCAD SHX Text
FOR ANY DAMAGE TO ANY PERSONAL PROPERTY.
AutoCAD SHX Text
1.5 THE CONTRACTOR WILL CONFINE THE CONSTRUCTION DEBRIS AND DUST TO THE CONSTRUCTION AREA, AWAY FROM COMPLETED TENANT SPACE OR COMMON AREAS, ALL AREAS OF THE BUILDING, ESPECIALLY ACCESS AREAS AND COMMON AREAS, ARE TO BE MAINTAINED IN A CLEAN AND ORDERLY FASHION. THE CONTRACTOR IS TO TURN THE IMPROVED PREMISES OVER THE PROPERTY MANAGER IN A CLEAN CONDITION, READY FOR OCCUPANCY BY THE TENANT.
AutoCAD SHX Text
1.6 THE CONTRACTOR WILL REMOVE ALL TRASH AND DEBRIS, INCLUDING
AutoCAD SHX Text
EXCESS MATERIALS FROM THE CONSTRUCTION SITE AND THE BUILDING
AutoCAD SHX Text
AND NO UNREASONABLE ACCUMULATION BE ALLOWED.
AutoCAD SHX Text
1.7 THE CONTRACTOR WILL COORDINATE THE DELIVERY OF AND
AutoCAD SHX Text
REMOVAL OF DEBRIS WITH THE PROPERTY MANAGER/OWNER.
AutoCAD SHX Text
1.8 THE CONTRACTOR WILL SUBMIT ALL CHANGE ORDERS TO THE
AutoCAD SHX Text
OWNER/ARCHITECT FOR APPROVAL AND THE BLUEPRINTS ARE TO BE
AutoCAD SHX Text
REVISED ACCORDINGLY.
AutoCAD SHX Text
1.9 UPON COMPLETION, THE CONTRACTOR WILL REMOVE ALL FOREIGN
AutoCAD SHX Text
MATERIALS FROM WINDOWS, FLOORS, GLASS, HARDWARE, ROOF AND
AutoCAD SHX Text
GENERAL WORK AREA(S).
AutoCAD SHX Text
1.10 THE CONTRACTOR WILL NOT UNDULY DISTURB "THE PEACEFUL
AutoCAD SHX Text
ENJOYMENT OF" ANY TENANTS IN THE BUILDING. ALL WORK THAT COULD
AutoCAD SHX Text
CAUSE DISRUPTION OR NOISY CONDITIONS SHALL BE COORDINATED WITH
AutoCAD SHX Text
THE OWNER/CLIENT PRIOR TO COMMENCEMENT OF SUCH ACTIVITY.
AutoCAD SHX Text
1.17 NOT USED
AutoCAD SHX Text
1.18 WHERE EXISTING WALLS, CEILINGS OR FIXTURES ARE REMOVED:
AutoCAD SHX Text
WALLS CEILINGS AND FLOORS SHALL BE PATCHED; ELECTRIC AND
AutoCAD SHX Text
PLUMBING SHALL BE CAPPED.
AutoCAD SHX Text
1.19 NOT USED
AutoCAD SHX Text
1.20 ANY ITEM OF WORK NECESSARY TO THE PROPER COMPLETION OF
AutoCAD SHX Text
CONSTRUCTION WHICH IS NOT SPECIFICALLY COVERED IN THESE
AutoCAD SHX Text
DOCUMENTS SHALL BE PERFORMED IN A MATTER DEEMED GOOD
AutoCAD SHX Text
PRACTICE OF THE TRADE.
AutoCAD SHX Text
1.24 NOT USED
AutoCAD SHX Text
1.25 NOT USED
AutoCAD SHX Text
1.26 NOT USED
AutoCAD SHX Text
1.27 NOT USED
AutoCAD SHX Text
1.28 USE AND INTERPRETATION OF THIS DRAWING:
AutoCAD SHX Text
A. GENERAL CONDITIONS OF THE CONTRACT FOR
AutoCAD SHX Text
CONSTRUCTION, AIA DOCUMENT A201, ARE A PART OF A CONTRACT
AutoCAD SHX Text
DOCUMENT AS DESCRIBED USE AND INTENT OF THE DRAWINGS. THE
AutoCAD SHX Text
CONTRACT DOCUMENTS INCLUDE NOT ONLY THE DRAWINGS, BUT
AutoCAD SHX Text
ALSO THE
AutoCAD SHX Text
OWNER-CONTRACTOR AGREEMENT, CONDITIONS OF THE
AutoCAD SHX Text
CONTRACT, THE SPECIFICATIONS, ADDENDA, AND MODIFICATIONS
AutoCAD SHX Text
ISSUED AFTER EXECUTION OF THE CONTRACT. THESE CONTRACT
AutoCAD SHX Text
DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ANY
AutoCAD SHX Text
ONE SHALL BE BINDING AS IF REQUIRED BY ALL. WORK NOT
AutoCAD SHX Text
COMPLETELY DELINEATED HEREON SHALL BE CONSTRUCTED OF THE
AutoCAD SHX Text
SAME MATERIALS AND DETAILED SIMILARLY AS WORK SHOWN MORE
AutoCAD SHX Text
COMPLETELY ELSEWHERE IN THE CONTRACT DOCUMENTS.
AutoCAD SHX Text
B. BY USE OF THE DRAWINGS FOR CONSTRUCTION OF THE
AutoCAD SHX Text
PROJECT THE OWNER REPRESENTS THAT HE HAS REVIEWED AND
AutoCAD SHX Text
APPROVED THE DRAWINGS, AND THAT THE CONSTRUCTION
AutoCAD SHX Text
DOCUMENT PHASE OF THE PROJECT IS COMPLETE. THE CONTRACTOR
AutoCAD SHX Text
REPRESENTS THAT HE HAS VISITED THE SITE, FAMILIARIZED HIMSELF
AutoCAD SHX Text
WITH THE
AutoCAD SHX Text
LOCAL CONDITIONS, VERIFIED FIELD DIMENSIONS AND
AutoCAD SHX Text
CORRELATED HIS OBSERVATIONS WITH THE REQUIREMENTS OF THE
AutoCAD SHX Text
CONTRACT DOCUMENTS.
AutoCAD SHX Text
C. THE CONTRACT SUM AND THE CONTRACT TIME MAY BE
AutoCAD SHX Text
CHANGED ONLY BY CHANGE ORDER TO THE CONTRACTOR
AutoCAD SHX Text
SIGNED BY THE OWNER AND THE ARCHITECT. ANY WORK PERFORMED
AutoCAD SHX Text
IN VARIANCE WITH THE CONTRACT DOCUMENTS AND NOT COVERED
AutoCAD SHX Text
BY THE ARCHITECT'S WRITTEN ORDER FOR A MINOR CHANGE IN THE
AutoCAD SHX Text
WORK OR A CHANGE ORDER, WILL NOT BE ACCEPTED.
AutoCAD SHX Text
D. AS INSTRUMENTS OF SERVICE, ALL DRAWINGS,
AutoCAD SHX Text
SPECIFICATIONS AND COPIES THEREOF FURNISHED BY THE
AutoCAD SHX Text
ARCHITECT ARE HIS SPECIFICATIONS AND PROPERTY. THEY ARE TO
AutoCAD SHX Text
BE USED ONLY FOR THIS PROJECT AND ARE NOT TO BE USED ON ANY
AutoCAD SHX Text
OTHER PROJECT. CHANGES TO THE DRAWINGS MAY ONLY BE MADE
AutoCAD SHX Text
BY THE ARCHITECT. ANY SUBMISSION OR DISTRIBUTION WITHOUT THE
AutoCAD SHX Text
EXPRESS WRITTEN CONSENT OF THE ARCHITECT MAY BE
AutoCAD SHX Text
CONSTRUED AS DEROGATION OF THE ARCHITECT COPYRIGHT OR
AutoCAD SHX Text
OTHER RESERVED RIGHTS.
AutoCAD SHX Text
1.29 ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE USING OR FOLLOWING
AutoCAD SHX Text
THE LATEST EDITION OF THE ADA STANDARDS FOR ACCESSIBLE DESIGN, AS
AutoCAD SHX Text
PUBLISHED BY THE STATE OF FLORIDA AND THE U.S. DEPARTMENT OF JUSTICE.
AutoCAD SHX Text THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE IMPLEMENTATION OF THE STANDARDS.
AutoCAD SHX Text
2.3 GC SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING
AutoCAD SHX Text
CONDITIONS PRIOR TO START OF WORK AND DURING CONSTRUCTION, AS
AutoCAD SHX Text
NECESSARY, TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY
AutoCAD SHX Text
ENTERING INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL
AutoCAD SHX Text
INDICATE HIS FAMILIARITY WITH THE SITE/FIELD CONDITIONS.
AutoCAD SHX Text
A. ALL 'HOLD' DIMENSIONS SHALL BE MONITORED TO ASSURE
AutoCAD SHX Text
CORRECTNESS.
AutoCAD SHX Text B. ANY DIMENSION REVISIONS/MODIFICATIONS ARE TO BE BROUGHT TO THE ATTENTION OF ARCHITECT PROJECT MANAGER FOR REVIEW/APPROVAL.
AutoCAD SHX Text
2.4 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM "BENCH MARK" OR
AutoCAD SHX Text
OTHER SIMILAR GUIDE ESTABLISHED PRIOR TO START OF CONSTRUCTION.
AutoCAD SHX Text HIGH POINTS, LOW POINTS, IRREGULARITIES IN FLOOR SLAB, PARTICULARLY, WHICH COULD IN ANY WAY AFFECT FABRICATION/INSTALLATION WORK OF OTHER TRADES OR VENDORS (E.G., CABINET CONTRACTORS), SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
AutoCAD SHX Text
A. NOT USED
AutoCAD SHX Text
2.5 GC SHALL DEMOLISH EXISTING PARTITION AND VARIOUS OTHER
AutoCAD SHX Text
ELEMENTS AS INDICATED ON PLAN AND COORDINATE THE REMOVAL OF ALL
AutoCAD SHX Text
RELATED ELECTRICAL SERVICE, PLUMBING AND ALL OTHER
AutoCAD SHX Text
APPURTENANCES INCLUDED THEREIN, REFER TO GENERAL DEMOLITION NOTES.
AutoCAD SHX Text
2.6 GC SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL CONSTRUCTION
AutoCAD SHX Text
DEBRIS AND FOR THE RETURN OF ANY BUILDING STANDARD COMPONENTS
AutoCAD SHX Text
IF REQUESTED BY THE BUILDING MANAGEMENT UNLESS OTHERWISE NOTED ON CD'S.
AutoCAD SHX Text
2.7 ALL CONVENTIONAL DRYWALL CONSTRUCTION, FURRING, SHEATHING,
AutoCAD SHX Text
THIS CONTRACT, SHALL BE AS DETAILED (REFER TO LEGEND ENTRIES, ON
AutoCAD SHX Text
CONSTRUCTION PLAN). DRYWALL JOINTS SHALL BE TAPED/SPACKLED
AutoCAD SHX Text
LEVEL. EXTERIOR CORNERS SHALL RECEIVE METAL CORNER
AutoCAD SHX Text
REINFORCING BEAD AND BE SPACKLED IN A CONVENTIONAL MANNER. NO
AutoCAD SHX Text
HORIZONTAL DRYWALL JOINTS SHALL BE ACCEPTED UNLESS APPROVED BY
AutoCAD SHX Text
ARCHITECT. BUTTED, UNTAPED DRYWALL JOINTS ARE NOT ACCEPTABLE.
AutoCAD SHX Text
FULL HEIGHT GYPSUM BOARD SHEETS SHALL BE USED THROUGHOUT FOR
AutoCAD SHX Text
FULL HEIGHT CONSTRUCTION.
AutoCAD SHX Text
A. NOT USED
AutoCAD SHX Text
B. NOT USED
AutoCAD SHX Text
1.13 THE GC SHALL VISIT THE JOB SITE AND VERIFY ALL CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. GC TO VERIFY AND INCLUDE ANY MEANS & METHODS REQUIRED FOR THE SCOPE OF WORK THAT WILL LEAD TO SUCCESSFUL COMPLETION OF CONSTRUCTION.
AutoCAD SHX Text
1.14 EXISTING CONDITIONS INDICATED ON THE DRAWINGS ARE ASSUMED AND SHALL BE VERIFIED BY THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, MATERIALS AND METHODS OF CONSTRUCTION AND COORDINATE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF SIGNIFICANT DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS PRIOR TO COMMENCING WORK.
AutoCAD SHX Text
1.15 PERFORM ALL WORK IN COMPLIANCE WITH APPLICABLE LAWS, CODES, ORDINANCES, RESTRICTIONS AND REQUIREMENTS. WORK SHALL BE INSPECTED BY APPROPRIATE AGENCIES.
AutoCAD SHX Text
1.16 THE TERMS, PROVIDED AND INSTALL AS USED THROUGHOUT THE NOTES AND/OR CONTRACT DOCUMENTS IS DEFINED AS SUPPLY, INSTALL, FINISH AND TEST EACH ITEM AS APPLICABLE, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
1.30 OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC
AutoCAD SHX Text
AUTHORITIES GOVERNING THE WORK.
AutoCAD SHX Text
1.31 REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND
AutoCAD SHX Text
CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR
AutoCAD SHX Text
OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY
AutoCAD SHX Text
WORK IN QUESTION.
AutoCAD SHX Text
CONFLICT, CONSULT THE ARCHITECT.
AutoCAD SHX Text
OR MOUNTED TO WALLS OR CEILINGS.
AutoCAD SHX Text
OTHERWISE NOTED.
AutoCAD SHX Text
THICKNESS OF FINISHES.
AutoCAD SHX Text
INSTALLATIONS.
AutoCAD SHX Text
OF NOT MORE THAN 450.
AutoCAD SHX Text
ACCORDANCE WITH ASTM-E 84.
AutoCAD SHX Text
1.39 UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS
AutoCAD SHX Text
1.38 COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED
AutoCAD SHX Text
OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "HOLD". ALLOW FOR
AutoCAD SHX Text
1.37 PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS
AutoCAD SHX Text
1.36 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF
AutoCAD SHX Text
SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION
AutoCAD SHX Text
CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS
AutoCAD SHX Text
1.33 OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE
AutoCAD SHX Text
ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.
AutoCAD SHX Text
1.35 PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
AutoCAD SHX Text
1.34 COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM
AutoCAD SHX Text
1.32 SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO
AutoCAD SHX Text
1.40 CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL HAVE A
AutoCAD SHX Text
FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX
AutoCAD SHX Text
POTENTIAL FIRE ON THE INSIDE OF THE BUILDING DUE TO INSTALLATION IN
AutoCAD SHX Text
1.41 INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO
AutoCAD SHX Text
UNCONCEALED SPACES SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE
AutoCAD SHX Text
THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450.
AutoCAD SHX Text
25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450 AS DETERMINED IN
AutoCAD SHX Text
1.42 MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE
AutoCAD SHX Text
NON COMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
AutoCAD SHX Text
2.1 PRIOR TO START OF CONSTRUCTION, GC SHALL COORDINATE SCHEDULING OF MEETINGS WITH HIS PROJECT PERSONNEL, THE OWNER'S REP(S). ARCHITECT PROJECT MANAGER, OTHERS, FOR REVIEW OF PROJECT SCOPE, DESIGN INTENT, CONSTRUCTION QUALITY EXPECTED, MEANS AND METHODS & FINAL DISCUSION OF DRAWINGS/DETAILS/QUESTIONS.
AutoCAD SHX Text
2.2 DIMENSIONS ON DRAWINGS ARE FINISH FACE TO FINISH FACE OF
AutoCAD SHX Text
PARTITIONS, COLUMNS, ETC., OR TO WHERE SHOWN, UNLESS OTHERWISE
AutoCAD SHX Text
NOTED. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS TAKE
AutoCAD SHX Text
PRECEDENCE OVER GRAPHIC REPRESENTATION. DETAIL DIMENSIONS
AutoCAD SHX Text
TAKE PRECEDENCE OVER PLAN DIMENSION.
AutoCAD SHX Text
2.8 ALL EXISTING HOLES/CRACKS IN SLAB AND THOSE RESULTING FROM
AutoCAD SHX Text
THE CONSTRUCTION PROCESS SHALL BE FILLED/REPAIRED AND THE
AutoCAD SHX Text
SURFACE PATCHED SMOOTH AND LEVEL WITH ADJACENT FLOOR
AutoCAD SHX Text
SURFACE, IN A MANNER ACCEPTABLE TO THE ARCHITECT.
AutoCAD SHX Text
2.9 ALL NECESSARY WOOD BLOCKING/GROUNDS, ETC., ARE TO BE
AutoCAD SHX Text
SUPPLIED AS FACTORY TREATED FIRE-PROOFED ELEMENTS. GC SHALL
AutoCAD SHX Text
FULLY COORDINATE SETTING/PLACEMENT OF THESE ELEMENTS AS REQ'D
AutoCAD SHX Text
BY LOCAL CODE/BUILDING OR SURROUNDING CONSTRUCTION CONDITIONS.
AutoCAD SHX Text
A. GROUNDS/BLOCKING MAY NOT BE WHOLLY SHOWN ON DRAWINGS
AutoCAD SHX Text
AND GOOD CONSTRUCTION PRACTICE SHALL GOVERN/ DETERMINE
AutoCAD SHX Text
SAID USE WHERE A QUESTION ARISES.
AutoCAD SHX Text
B. NOT USED
AutoCAD SHX Text
C. NOT USED
AutoCAD SHX Text
2.10 GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK
AutoCAD SHX Text
WHICH MAY NOT FALL INTO JURISDICTION OF A SPECIFIC TRADE, BUT IS
AutoCAD SHX Text
REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF
AutoCAD SHX Text
CONSTRUCTION.
AutoCAD SHX Text
2.11 NOT USED
AutoCAD SHX Text
2.12 NOT USED
AutoCAD SHX Text
2.13 GC, SUBCONTRACTORS, AND ALL VENDORS ARE TO VERIFY ALL
AutoCAD SHX Text
CLEARANCES (CORRIDORS, STAIRS, ELEVATORS, ETC.) REQUIRED FOR
AutoCAD SHX Text
DELIVERIES AND PASSAGE OF ALL JOB MATERIALS/EQUIPMENT PER
AutoCAD SHX Text
LANDLORD'S RULES & REGULATIONS.
AutoCAD SHX Text
A. GC SHALL SCHEDULE FOR AND INCLUDE COSTS/ FEES
AutoCAD SHX Text
NECESSARY FOR USE OF BUILDING ELEVATOR OR ANY SPECIAL
AutoCAD SHX Text
CARTAGE, RIGGING, HOISTING, DELIVERIES, TRANSPORTATION,
AutoCAD SHX Text
CONNECTED WITH CONTRACT WORK.
AutoCAD SHX Text
B. GC SHALL COORDINATE CLOSELY WITH VARIOUS ARCHITECT
AutoCAD SHX Text
VENDORS OR CONTRACTORS, REGARDING INFORMATION IN PART
AutoCAD SHX Text
"A" NOTE ABOVE.
AutoCAD SHX Text
2.14 EXISTING FINISHES IN ANY AREA OF THIS PROJECT SHALL BE
AutoCAD SHX Text
PATCHED AND SPACKLED AS REQUIRED IF DAMAGED IN ANY MANNER
AutoCAD SHX Text
DURING CONSTRUCTION AND SHOULD BE REPAIRED TO SATISFACTION
AutoCAD SHX Text
OF ARCHITECT & THE BUILDING LANDLORD.
AutoCAD SHX Text
2.15 HARDWARE SHALL BE PROVIDED BY GC AS SPECIFIED. SEE DOOR FRAME AND HARDWARE SCHEDULES.
AutoCAD SHX Text
2.16 ALL SUBSTITUTIONS, I.E., "EQUALS" MUST BE SUBMITTED TO ARCHITECT/OC PROJECT MANAGER FOR WRITTEN APPROVAL PRIOR TO SUBSTITUTION.
AutoCAD SHX Text
2.17 GC SHALL REMOVE EXISTING FLOOR COVERING WHENEVER
AutoCAD SHX Text
DESIGNATED FOR REMOVAL.
AutoCAD SHX Text
2.18 NOT USED
AutoCAD SHX Text
2.19 NOT USED
AutoCAD SHX Text
2.20 NOT USED
AutoCAD SHX Text
3.4 CEILING PLANE SHALL BE LEVEL AND TRUE, AND IN ALIGNMENT WITH ALL LIGHTING, SPRINKLERS, HVAC AND OTHER ELEMENTS INCORPORATED IN ITS CONSTRUCTION. GRID SHALL BE CONTINUOUS THROUGHOUT THE DEMISED AREA EXCEPT WHERE NOTED ON CDs. 3.5 NOT USED 3.6 NOT USED 3.7 MECHANICAL, HVAC AND PLUMBING ELEMENTS SHALL AT NO TIME COME IN CONTACT WITH CEILING CONSTRUCTION EXCEPT AS NECESSARY PENETRATIONS MAY REQUIRE. 3.8 ACCESS SHALL BE PROVIDED BY GC AS REQUIRED FOR INSTALLATION AND MAINTENANCE OF MECHANICAL, ELECTRICAL AND OTHER ELEMENTS WITHIN CEILING PLENUM AND AS REQUIRED BY CODE. LOCATIONS FOR SPECIAL ACCESS DOORS, HATCHES, ETC. SHALL BE COORDINATED WITH OTHER TRADES AND APPROVED BY ARCHITECT. AS- BUILT REFERENCE PLANS SHALL BE PROVIDED TO ARCHITECT. 3.9 INSPECTIONS, AS REQUIRED BY LOCAL AUTHORITIES SHALL BE COORDINATED BY GC PRIOR TO CLOSING OF CEILING. 3.10 SHOP DRAWINGS FOR ALL RELATED TRADES (PLUMBING, SPRINKLER, HVAC) SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW/APPROVAL PRIOR TO MANUFACTURING AND INSTALLATION. A COORDINATED SHOP DRAWING FOR ALL VISIBLE CEILING ELEMENTS SHALL BE SUBMITTED.
AutoCAD SHX Text
3.11 HVAC SUPPLY, RETURN, EXHAUST GRILLES SHALL BE AS SPECIFIED IN MECHANICAL AND ARCHITECTURAL DRAWINGS. ALL HVAC ELEMENTS SHALL BE BRITE WHITE (TO MATCH CEILING) INSTALLED FLUSH AND TRUE AND CENTERED WITHIN THE CEILING GRID. LOCATIONS SHALL BE PER APPROVED MECHANICAL PLANS, UNLESS OTHERWISE NOTED ON CD'S.
AutoCAD SHX Text
3.12 ARCHITECTURAL CEILING PLAN SHALL GOVERN WITH RESPECT TO LOCATIONS FOR CEILING PENETRATIONS AS AESTHETIC AND FUNCTIONAL CONSIDERATIONS DICTATE. MECHANICAL DOCUMENTS SHALL TAKE PRECEDENCE WITH RESPECT TO OVERALL SCOPE OF WORK.
AutoCAD SHX Text
3.13 CLEARANCES FOR ALL RELATED CEILING PLENUM THAN ONE ROOM, SHALL BE ACOUSTICALLY LINED NO ADDITIONAL COST.
AutoCAD SHX Text
3.14 NOT USED
AutoCAD SHX Text
3.15 NOT USED
AutoCAD SHX Text
1.21 ALL NEW MATERIALS AND FINISHES SHALL MATCH EXISTING UNLESS SPECIFIED OTHERWISE, SEE OWNER AND/OR ARCHITECT FOR APPROVAL OF ALTERNATIVES.
AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315
AutoCAD SHX Text
AS SHOWED
AutoCAD SHX Text 18268
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
AJC
AutoCAD SHX Text
AJC
AutoCAD SHX Text
AJC
AutoCAD SHX Text
AutoCAD SHX Text
AJC
AutoCAD SHX Text
BID/PERMIT ISSUE SET 2
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
AutoCAD SHX Text
NRA
AutoCAD SHX Text
BID/PERMIT ISSUE SET
AutoCAD SHX Text 11/11/19
AutoCAD SHX Text
AutoCAD SHX Text
NRA
AutoCAD SHX Text
90% CD'S
AutoCAD SHX Text 09/26/19
AutoCAD SHX Text
AJC
AutoCAD SHX Text
NRA
AutoCAD SHX Text
60% CD'S
AutoCAD SHX Text 08/01/19
AutoCAD SHX Text
AutoCAD SHX Text
RE-BID / PERMIT ISSUE SET 2
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
NRA
AutoCAD SHX Text
AJC
AutoCAD SHX Text
CONSTRUCTION AIR CONDITIONING FILTERS.
AutoCAD SHX Text
1.11 COORDINATE WITH ENGINEERING DRAWINGS FOR PLACEMENT OF
REFLECTED CLG & MECH. SYS (CONT.)
4.0 ELECTRICAL PLAN NOTES
ELECTRICAL PLAN NOTES (CONT.)
Consultant ● Seal/Signature
Sheet Title:
Project Number
Scale
File Name
Drawn By
Checked ByAR
CH
ITE
CT
UR
E
PL
AN
NI
NG
IN
TE
RI
OR
D
ES
IG
N
SP
AC
E
PL
AN
NI
NG
Issue Date
Project Status
PR
IN
TE
D
ON
Client Information
ADCARCHITECTURAL DESIGN COLLABORATIVE
Architect ● Seal/Signature
Issue
Project Documents for:
Date Issue Description
Project:
Check By
945 N. PENNSYLVANIA AVENUE
WINTER PARK, FLORIDA 32789
OFFICE: (407) 629-1188
FAX: (407) 388-1220
WWW. ADCINTERNATIONAL.NET
6.0 FINISH PLAN NOTES
7.0 NOT USED
8.0 GENERAL DEMOLITION NOTES
5.0 NOT USED
FINISH PLAN NOTES (CONT.) GEN DEMOLITION NOTES (CONT.)
Ocoee Security
SECURITY UPGRADE
OCOEE, FL 34761
475 STORY RD #15
ORANGE COUNTY
A00.11
RE-BID / PERMIT ISSUE SET 2
05/04/2022
AutoCAD SHX Text
5.1 NOT USED 5.2 NOT USED 5.3 NOT USED 5.4 NOT USED 5.5 NOT USED
AutoCAD SHX Text
4.12 FLOOR OUTLETS SHALL BE FLUSH TYPE UNLESS PROHIBITED BY BUILDING MANAGEMENT. GC SHALL FURNISH CUT /SAMPLE TO ARCHITECT FOR APPROVAL. UNDER CARPET WIRING MAY NOT BE USED EXCEPT AS SPECIFIED AND AS LOCAL CODES AND BUILDING MANAGEMENT PERMITS. 4.13 SURFACE MOUNTED WIRING DEVICES SHALL NOT BE USED BY GC, HIS SUBS OR ANY ELECTRICAL VENDOR OR INSTALLER, EXCEPT AS SPECIFIED TO COORDINATE WITH FURNITURE/MILLWORK INSTALLATION. 4.14 COORDINATION OF ELECTRICAL WORK WITH HVAC, CABINET WORK, CARPENTRY, FURNITURE, SHALL BE ASSURED BY GC. 4.15 NOT USED 4.16 AVAILABILITY OF ADEQUATE POWER SERVICE SHALL BE VERIFIED BY ELECTRICAL CONTRACTOR. COSTS FOR ADDITIONAL CIRCUIT PANELS, ETC., IF REQUIRED, SHALL BE INCLUDED IN BASE BID. 4.18 EXISTING SIGNAL CABLES, IF IN USE BY RESIDING TENANTS, MAY NOT BE DISTURBED OR CUT. GC SHALL BE RESPONSIBLE TO RESTORE ANY SERVICES WHICH ARE INADVERTENTLY INTERRUPTED. 4.19 REFER TO SCOPE OF MECHANICAL AND HVAC INSTALLATIONS FOR RELATED ELECTRICAL WORK TO BE INCLUDED. 4.20 SLEEVES SHALL BE PROVIDED BY GC TO ALLOW DATA / TELEPHONE CABLES TO PASS THROUGH FIRE RATED PARTITIONS AND SHALL BE FIRESTOPPED BY G.C.
AutoCAD SHX Text
3.17 FIRE PROTECTION SYSTEMS AS SPECIFIED OR REQUIRED BY CODE,
AutoCAD SHX Text
SHALL BE PROVIDED BY GC. MINIMUM SPRINKLER INSTALLATION MUST MEET
AutoCAD SHX Text
REQUIREMENTS OF NFPA 13. TILE TO PROVIDE A UNIFIED, CONSISTENT AND
AutoCAD SHX Text
AESTHETIC ARRANGEMENT. HEADS SHALL BE WHITE FLUSH TYPE OR
AutoCAD SHX Text
BUILDING STANDARD IF EQUAL OR BETTER.
AutoCAD SHX Text
3.18 SPRINKLER HEAD LOCATION SHALL BE COORDINATED WITH OTHER
AutoCAD SHX Text
TRADES BY GC AND SHALL BE AS SPECIFIED BY ENGINEER OR AS REQ'D BY
AutoCAD SHX Text
CODE. SPRINKLERS SHALL BE CENTERED WITHIN EACH CEILING.
AutoCAD SHX Text
3.19 ARCHITECTURAL PLAN SHALL GOVERN LOCATION AND ENGINEERING PLANS SHALL PREVAIL IN QUESTIONS OF CIRCUITING AND SCOPE.
AutoCAD SHX Text
3.20 CUT SHEETS FOR ALL FIXTURES SHALL BE SUBMITTED TO THE
AutoCAD SHX Text
ARCHITECT BY GC FOR REVIEW/APPROVAL. SUBSTITUTIONS MUST BE
AutoCAD SHX Text
APPROVED BY ARCHITECT.
AutoCAD SHX Text
3.21 EMERGENCY LIGHTING AND ANNUNCIATOR / ALARM SYSTEMS SHALL BE
AutoCAD SHX Text
SPECIFIED BY ENGINEER.
AutoCAD SHX Text
3.22 NEW SWITCHES PER SPECIFICATION.
AutoCAD SHX Text
3.23 ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE
AutoCAD SHX Text
LATEST "NATIONAL ELECTRICAL CODE" AND ANY AND ALL APPLICABLE STATE
AutoCAD SHX Text
AND LOCAL CODES/ORDINANCES.
AutoCAD SHX Text
3.24 CLEANING-BEFORE JOB COMPLETION, THE FOLLOWING SHALL BE
AutoCAD SHX Text
SATISFIED:
AutoCAD SHX Text
A. ALL LIGHT FIXTURE INTERIORS AND LENSES SHALL BE WIPED
AutoCAD SHX Text
CLEAN OF ALL CONSTRUCTION DUST, GRIME, FINGERMARKS, ETC.,
AutoCAD SHX Text
AND BE FULLY FUNCTIONING, MECHANICALLY AND ELECTRICALLY.
AutoCAD SHX Text
B. ALL LAMPING WILL BE NEW AND FUNCTIONAL.
AutoCAD SHX Text
3.25 PROTECTION: ALL ELECTRICAL ELEMENTS, WHEN INSTALLED, SHALL BE
AutoCAD SHX Text
PROTECTED FROM DAMAGE BY OTHER TRADES. COVER PLATES SHALL BE
AutoCAD SHX Text
INSTALLED AFTER FINISH MATERIALS HAVE BEEN APPLIED.
AutoCAD SHX Text
3.26 NOT USED
AutoCAD SHX Text
3.27 SEE REFLECTED CEILING PLAN FOR LAYOUT OF CEILING AND FIXTURES.
AutoCAD SHX Text
3.28 LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER
AutoCAD SHX Text
SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING
AutoCAD SHX Text
ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
3.29 LOCATIONS OF FIXTURES, REGISTERS, SWITCHES, ETC. SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO COMMENCING CONSTRUCTION. REFER TO MEP DRAWINGS, FIRE PROTECTION DRAWINGS, AND PROJECT MANUAL FOR DESIGN OF THESE SYSTEMS.
AutoCAD SHX Text
3.30 ALL FIXTURES TO BE PER ELECTRICAL DRAWINGS.
AutoCAD SHX Text
4.1 SCOPE: GC SHALL PROVIDE ALL ELECTRICAL WORK AS SHOWN OR IMPLIED IN THESE DRAWINGS AND RELATED ENGINEERING DRAWINGS (IF ANY) INCLUDING ALL CONDUIT RUNS FOR POWER AND SIGNAL. DRAG LINES, PULL BOXES, WIRING, RECEPTACLES AND SWITCHING DEVICE, CORE DRILLING AND PATCHING, ETC.; AS SPECIFIED OR IMPLIED OR AS REQUIRED BY CODE OR BUILDING STANDARDS. 4.2 EQUIPMENT: TELEPHONE AND DATA EQUIPMENT, TERMINALS, ETC., EXCEPT AS SPECIFICALLY CALLED FOR, SHALL BE PROVIDED BY OTHERS. GC SHALL PROVIDE FOR COORDINATION WITH VENDORS/INSTALLERS REGARDING DELIVERIES AND SCHEDULES AS DIRECTED BY ARCHITECT. 4.3 LOCATIONS AND DIMENSIONS SHALL BE PER ARCHITECTURAL DRAWINGS. ENGINEERING DOCUMENTS (IF ANY) SHALL PREVAIL IN CASE OF VARIATION IN SPECIFICATIONS. DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF ARCHITECT BEFORE START OF WORK. FURNITURE INDICATED ON PLANS IS FOR REFERENCE ONLY. 4.4 VARIATIONS FROM WORK SPECIFIED, DUE TO AVAILABILITY OF MATERIALS; FIELD CONDITIONS, VARIATIONS IN EQUIPMENT SPECS, ETC., MAY BE MADE WITH THE APPROVAL OF ARCHITECT. 4.5 FIELD VERIFICATIONS: G.C. AND SUBCONTRACTORS SHALL BE RESPONSIBLE TO VERIFY FIELD CONDITIONS AND DIMENSIONS BEFORE BEGINNING WORK. SIZES OF CONDUITS AND PULL BOXES SHALL BE ADEQUATE FOR CABLES /SERVICE SPECIFIED. 4.6 NOT USED 4.7 COMPLIANCE: ALL WORK SHALL BE PERFORMED IN COMPLETE COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE OR LOCAL CODES AND ORDINANCES HAVING JURISDICTION. 4.8 FLUSH MOUNTED FLOOR P/C BOX. COORDINATE WITH ELECTRICAL DRAWINGS. GC SHALL RETAIN THE SERVICES OF A TESTING AGENCY TO FIELD VERIFY IF EXISTING CONCRETE SLAB IS POST TENSION & TO LOCATE THE EXISTING POST-TENSION TENDONS PRIOR TO PENETRATING THE EXISTING SLAB TO AVOID DAMAGING THE EXISTING TENDONS. THE TENDONS SHALL BE LOCATED BY A MEANS OF A HILTI FERROSCAN DEVICE OR APPROVED EQUAL. THE RESULTS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW A MINIMUM OF 48 HOURS PRIOR TO PENETRATING THE EXISTING SLAB. CONTRACTOR TO NOTIFY ARCHITECT IN WRITING IF LOCATION OF FLOOR BOX SPECIFIED INTERFERES WITH EXISTING TENDONS.
AutoCAD SHX Text
4.9 COMPATIBILITY: ALL DEVICES, WIRING, ETC. SHALL BE COMPATIBLE, EACH WITH ONE ANOTHER AND WITH EXISTING WORK AND BUILDING STANDARDS. 4.10 CIRCUITING SHALL BE AS SHOWN ON ENGINEERING DOCUMENTS. 4.11 PROTECTION: ALL ELECTRICAL DEVICES, WHEN INSTALLED, SHALL BE PROTECTED FROM DAMAGE BY OTHER TRADES. COVER PLATES SHALL BE INSTALLED AFTER FINISH MATERIALS HAVE BEEN APPLIED. SEE FINISH PLAN.
AutoCAD SHX Text
PER ELECTRICAL DRAWINGS.
AutoCAD SHX Text
4.28 IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT
AutoCAD SHX Text
ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
4.27 PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE
AutoCAD SHX Text
DO NOT INSTALL BACK-TO-BACK.
AutoCAD SHX Text
4.26 INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES.
AutoCAD SHX Text
CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
4.25 INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR
AutoCAD SHX Text
4.24 GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE.
AutoCAD SHX Text
EQUIPMENT.
AutoCAD SHX Text
4.23 VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER
AutoCAD SHX Text
WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION.
AutoCAD SHX Text
4.22 VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS
AutoCAD SHX Text
SYSTEMS.
AutoCAD SHX Text
4.21 COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY
AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315
AutoCAD SHX Text
6.1 ALL FINISH MATERIAL INDICATED TO BE BY GC UNLESS OTHERWISE NOTED IN FINISH SCHEDULES, FINISH PLAN AND SPECIFICATIONS 6.2 GC AND VENDORS SHALL DETERMINE AVAILABILITY OF ALL FINISH MATERIALS. ANY DELIVERY SCHEDULE THAT POTENTIALLY MAY CAUSE COORDINATION PROBLEMS DURING THE FINAL STAGES OF CONSTRUCTION/INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT , EARLY ON, FOR POSSIBLE RE-EVALUATION OF MATERIAL DESIGNATION. 6.3 NOT USED 6.4 PAINT FOR WALL FINISHES SHALL BE PROVIDED AS A THREE (3) COAT EGGSHELL LATEX ENAMEL PAINT INSTALLATION [ONE (1) PRIME AND TWO (2) FINISHED COAT], COLORS AS SPECIFIED. METAL ELEMENTS AND DOOR FRAMES SHALL HAVE A THREE COAT SEMI-GLOSS ALKYD ENAMEL FINISH TO MATCH EXISTING. 6.5 NOT USED 6.6 UPON COMPLETION OF CONSTRUCTION, GC SHALL REMOVE ALL PAINT, WALLCOVERING PASTE, ETC., FROM WHERE IT HAS SPILLED, SPLASHED, OR SPATTERED. 6.7 NOT USED 6.8 PROVIDE STRAIGHT, FLUSH RESILIENT BASE AT CARPETED AREAS, AND COVED. TOP SET RESILIENT BASE AT RESILIENT FLOORING, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
8.21 PROVIDE PROTECTION OF INTERIOR FINISHES DURING DEMOLITIONS/CONSTRUCTION.
AutoCAD SHX Text
REFER TO LANDLORD'S RULES AND REGULATIONS.
AutoCAD SHX Text
8.22 GC TO MAINTAIN ACCESS THROUGH LOADING DOCK AT ALL TIMES. VERIFY WITH BUILDING
AutoCAD SHX Text
MANAGEMENT THE NUMBER OF VEHICLES AND/OR DUMPSTERS PERMITTED IN THE LOADING DOCK
AutoCAD SHX Text
AREA AT ONE TIME. LOADING DOCK AREA REFERS TO AREA OUTSIDE OF THE BAYS.
AutoCAD SHX Text
8.23 THE GENERAL CONTRACTOR (GC) SHALL COORDINATE ALL RECYCLING AND ALL DISPOSAL OF
AutoCAD SHX Text
ALL DEMOLISHED MATERIAL AND EQUIPMENT WITH THE CONSTRUCTION AND DEMOLITION WASTE
AutoCAD SHX Text
MANAGEMENT PLAN AND COMPANY PRIOR TO REMOVAL AND DEMOLITION
AutoCAD SHX Text
OF MATERIALS AND EQUIPMENT.
AutoCAD SHX Text
8.24 REMOVE CEILING, SOFFIT, BULKHEAD, MISC. ASSEMBLIES SHOWN DASHED, INCLUDING BUT NOT
AutoCAD SHX Text
LIMITED TO SHEATHING, FINISHES, STUD FRAMING, FURRING, BLOCKING AND BRACING.
AutoCAD SHX Text
8.25 REMOVE EQUIPMENT AND ASSOCIATED EQUIPMENT INSTALLED IN OR MOUNTED TO FLOOR,
AutoCAD SHX Text
WALL, AND CEILING ASSEMBLIES SHOWN DASHED.
AutoCAD SHX Text
8.26 MAINTAIN THE CONTINUITY OF CONSTRUCTION OF ALL FIRE-RATED ASSEMBLIES (I.E.
AutoCAD SHX Text
DOORS, GYPSUM ENCLOSURES, SPRAYED FIRE PROOFING, ETC) AT ALL EXISTING AND NEW
AutoCAD SHX Text LOCATIONS INCLUDING BUT NOT LIMITED TO STRUCTURAL COLUMNS, BEAMS, AND FLOOR SLAB.
AutoCAD SHX Text
8.27 COORDINATE ALL SHUTDOWNS IN UTILITY SERVICE WITH OWNER PRIOR TO PERFORMING
AutoCAD SHX Text
SHUTDOWNS IN UTILITY SERVICE.
AutoCAD SHX Text
8.1 REMOVE EXISTING RECEPTACLES, TELEPHONE, SWITCHES, AND ANY ELECTRICAL DEVICES IN WALLS TO BE DEMOLISHED. RELOCATE ANY OF THESE DEVICES AS INDICATED OR REQUIRED BY THE DRAWINGS, ARCHITECT, OR OWNER REPRESENTATIVE. PROVIDE ARCHITECT WITH AS-BUILT DRAWINGS OF FINAL INSTALLATION FOR RECORD PURPOSES. CONTRACTOR IS NOTIFIED THAT NOT ALL EXISTING DEVICES MAY HAVE BEEN INDICATED ON THE DRAWINGS AND THAT SOME EXISTING ELECTRICAL DEVICES MAY NOT HAVE BEEN SHOWN IN THEIR ACTUAL LOCATION. CONTRACTOR IS REQUIRED TO VISIT SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS PRIOR TO DETERMINING THE WORK THAT NEEDS TO BE ACCOMPLISHED AS PART OF HIS/HER BID. 8.2 THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUTTING, EXTENDING, CONNECTING, REPAIRING, ADAPTING, AND OTHER WORK COINCIDENTAL HERETO. TOGETHER WITH SUCH TEMPORARY INSTALLATIONS AS MAY BE NECESSARY TO SATISFY THE DEMOLITION PROGRAM. APPROVAL SHALL BE SECURED FROM THE LANDLORD/ ARCHITECT PRIOR TO CUTTING/DRILLING ANY STRUCTURAL SUPPORT. 8.3 ALL BUILDING CONSTRUCTION AFFECTED BY THE REMOVAL, RELOCATION OR INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL BE REPAIRED AND FINISHED AS REQUIRED TO MATCH EXISTING CONDITION OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, SPECIFICATIONS, OR OWNER'S REPRESENTATIVE.
AutoCAD SHX Text
8.14 WHERE EXISTING WORK IS DAMAGED IN THE EXECUTION OF THIS CONTRACT, OR WHERE OPENINGS ARE LEFT DUE TO THE REMOVAL OF PIPES, EQUIPMENT OR APPARATUS, THE SAME SHALL BE REPAIRED OR CLOSED UP TO CORRESPOND IN MATERIAL, QUALITY, SHAPE AND FINISH WITH THAT OF SIMILAR AND ADJOINING WORK, UNLESS OTHERWISE CALLED FOR. WHERE DAMAGE IS UNREPAIRABLE, NEW ITEMS OR EQUIPMENT SHALL BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL NECESSARY WATERPROOFING, FIRE STOPPING AND SEALING OF PENETRATIONS LEFT FROM REMOVED EQUIPMENT OR PRODUCED BY THIS SCOPE OF WORK. 8.15 INTERRUPTION OF EXISTING SERVICES AND/OR OPERATION OF FACILITIES SHALL BE KEPT TO A MINIMUM.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .