Y22-760_Drawings.pdf
PDF 38 MB Posted
- Solicitation number
- Y22-760
- Issued by
- Orange County, Orlando City, Florida
About this file
The file is a comprehensive set of architectural and engineering design drawings for the Orange County Fire Rescue Emergency Operations Center Interior Alterations project located at 6590 Amory Court in Winter Park, Florida. The project involves interior renovations to an existing facility, including technology upgrades, electrical and mechanical modifications, and renovated building entry areas. The design documents are dated July 7, 2021, with an estimated project cost of $3,000,000.00, and were prepared by KMF Architects with engineering support from SGM Engineering, Base Consultants, and Thorburn Associates Inc.
The renovation scope includes reconfiguring multiple spaces such as the Emergency Operations Center, message center, breakout rooms, IT control room, and administrative areas. The design incorporates new media wall systems, audio-visual equipment, raised flooring, technology infrastructure, and updated finishes. The project will maintain the existing building's occupancy type and construction type while modernizing the interior spaces. Specific upgrades include new partition walls, ceiling systems, floor treatments, lighting, electrical systems, and audiovisual technology infrastructure. The drawings detail precise specifications for demolition, new construction, equipment placement, and technical system integrations across multiple disciplines including architectural, electrical, mechanical, and fire protection systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Y22-760.pdf | ||
| Y22-760_Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fire Rescue - EOC Orange County Government 6590 Amory Court Winter Park, FL 32792
KMF Architects
839 N. Magnolia Ave.
Orlando, FL 32803 407.298.1988
LIC # AR 93580
SGM Engineering
935 Lake Baldwin Lane Orlando, FL 32814 407.767.5188
ELECTRICALARCHITECTURE
VICINITY MAP
10-22-30-8821-00-020
PARCEL ID NUMBER
PROJECT LOCATION
SHEET ISSUE
COVER SHEET,
DRAWING INDEX
AND VICINITY
PLAN
01G.000
SHEET TITLESHEET
G.000 COVER SHEET, DRAWING INDEX AND VICINITY PLAN
OVERALL FLOOR PLANA.100
G.010
2021.07.07
DRAWING INDEX
G.012
ISSUE NO. DATE
E.001 ELECTRICAL SYMBOLS LEGEND
ED.101 PARTIAL DEMO. PLAN
ED.111
E L E C T R I C A LA R C H I T E C T U R A L
ACCESSIBILITY DETAILS
ACCESSIBILITY DETAILS
LEVEL 2 INTERIOR ALTERATIONS
6590 AMORY COURT WINTER PARK, FLORIDA, 32792
ORANGE COUNTY GOVERNMENT,
FIRE RESCUE EMERGENCY OPERATIONS CENTER
CODES IN EFFECT:
SCOPE OF PROJECT:
ADDRESS:
PROJECT:
CARL SHEA; KMF ARCHITECTS, 407.298.1988ARCHITECT CONTACT:
THE SCOPE OF WORK FOR THIS PROJECT IS INTERIOR ALTERATIONS INCLUDING TECHNOLOGY UPGRADES AND
ASSOCIATED ELECTRICAL AND MECHANICAL, AND RENOVATED BUILDING ENTRY AREA
THE OCCUPANCY TYPE, CONSTRUCTION TYPE AND BUILDING AREA WILL NOT CHANGE AS A RESULT OF THESE
ALTERATIONS.
THE INFORMATION CONTAINED BELOW REFERS TO THE OVERALL, EXISTING BUILDING, AND IS FOR INFORMATIVE
PURPOSES. ONLY AS IT IS KNOWN AND AS PRESENTED TO THE ARCHITECT BY THE OWNER.
A.J. MURRAY- CAPITAL PROJECTS DIVISION - ORLANDO, FL 32801
TEL. 407.836.0050
COUNTY PROJECT MANAGER:
- FLORIDA BUILDING CODE, BUILDING, 7TH EDITION
- FLORIDA EXISTING BUILDING CODE, 7TH EDITION
- FLORIDA BUILDING CODE, ACCESSIBILITY, 7TH EDITION
- FLORIDA FIRE PREVENTION CODE, 7TH EDITION (ADOPTED DECEMBER 31, 2020)
PARTIAL FLOOR PLANA.101
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
KMFARCHITECTS.COM
407.298.1988
FI
R E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
PARTIAL DEMOLITION PLANAD.101
M.001 MECHANICAL SYMBOLS LEGEND
M E C H A N I C A L
F.001 FIRE PROTECTION SYMBOLS LEGEND
F I R E P R O T E C T I O N
Thorburn Associates Inc.
7780 Chapel Hill Drive Orlando, FL 32819 407.898.5645
TECHNOLOGY
G.100 PARTITION TYPES
PARTIAL REFLECTED CEILING PLANA.111
INTERIOR ELEVATIONSA.401
DOOR SCHEDULE & DETAILSA.601
PARTIAL DEMO REFLECTED CEILING PLAN
E.101 PARTIAL PLAN
E.111 PARTIAL REFLECTED CEILING PLAN
ES.001 SYSTEMS SYMBOLS LEGEND
ESD.101 PARTIAL DEMO. PLAN
ES.101 PARTIAL PLAN
M.002 MECHANICAL GENERAL NOTES
MD.101 PARTIAL DEMO. PLAN
M.101 PARTIAL PLAN
M.801 DETAILS
PARTIAL DEMO. REFLECTED CEILING PLANAD.111
ACCESS FLOOR PLANA.102
INTERIOR ELEVATIONSA.402
INTERIOR ELEVATIONSA.403
INTERIOR ELEVATIONSA.404
LIFE SAFETY PLANLS.101
DEMO ELEVATIONSAD.401
BASE Consultants
1214 E. Concord Street Orlando, FL 32803 407.377.7227
STRUCTURAL
EOC FURNITURE PLANI.201
MILLWORK SECTIONSA.406
SHEET TITLESHEET
DRAWING INDEX
ISSUE NO. DATE
TA.101 AV FLOOR PLAN
T E C H N O L O G Y
FLOOR AND WALL SYSTEM DETAILSA.340
S.101 STRUCTURAL NOTES AND DETAILS
S T R U C T U R A L
TA.301 SECTIONS AND ELEVATIONS
TA.302 SECTIONS AND ELEVATIONS
TA.501 RACK DETAILS AND ELEVATIONS
FINISH PLANI.101
DETAILSA.602
E.801 DETAILS
ES.801 DETAILS
M.701 SCHEDULES
F.101 PARTIAL PLAN
F.801 DETAILS
ENLARGED FLOOR PLANSA.351
FD.101 PARTIAL DEMO. PLAN
ERIC KLEINSTEUBER; KMF ARCHITECTS, 407. 298.1988ARCHITECT OF RECORD:
Orange County Capital Projects Division 400 E. South St., 5th Floor Orlando, FL 32801 407.836.0050
OWNER CONTACT
E.701 SCHEDULES 01
ES.501 RISER DIAGRAMS 01
TA.201 AV REFLECTED CEILING PLAN 01
TA.002 SCHEDULES
TA.003 RISER DIAGRAMS
DEMO ELEVATIONSAD.402 01
FLOOR AND WALL SYSTEM DETAILSA.341 01
Carlsson Construction Estimators Inc.
1000 Savage Court, Suite 104 Longwood, FL 32750 407.792.9988
Cost Estimating
DETAILSA.603 01
INTERIOR FINISHESI.102 01
INTERIOR FINISHESI.103 01
INTERIOR FINISHES & MEDIA WALL PANEL MATRIXI.104 01
01TA.001 SHEET INDEX AND NOTES
TA.400 FUNCTIONALS 01
TA.401 FUNCTIONALS 01
TA.601 INTERFACE PLATES 01
TA.701 COORDINATION DETAILS 01
Orange County Government Mayor - Jerry Demings Commissioner - Emily Bonilla Chief James Fitzgerald Chief John Westmoreland Chief Michael Wajda
TA.402 FUNCTIONALS 01
TA.403 FUNCTIONALS 01
TA.404 FUNCTIONALS 01
REPLACE ENTRY CURTAIN WALL ADD ALTERNATEA.800 01
* ISSUED AS PART OF ADD ALTERNATE
REFLECTED CEILING DIMENSION PLANA.112 01
TA.702 COORDINATION DETAILS 01
2021.07.07 2021.07.07 2021.07.07
2021.07.07
2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07 2021.07.07
2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07
2021.07.07 2021.07.07 2021.07.07
2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07
2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07 2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07
2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07
G.200 UL DETAILS 01 2021.07.07
m in
24 min m in
36 min
12 min 12 min
60 min base ar ar
17-25
6 max m in
(a) elevation
(b) plan
11 min m in
8 min
9 min
(a) elevation
(b) plan m in
25 max
4 max
X ³
X m ax X m in m ax m ax m ax
>20-25 max20 max
(a) (b)
10 max m ax m in
LC
min max dimension showing English units above the line (in inches unless otherwise specified) dimension for small measurements (in inches unless otherwise specified) direction of travel or approach boundary of clear floor space or maneuvering clearance centerline minimum maximum a permitted element or its extension a wall, floor, ceiling or other element cut in section or plan a highlighted element in elevation or plan
CONVENTION DESCRIPTION
location zone of element, control or feature greater than>
< less than
33-36 dimension showing a range with minimum -maximum (in inches unless otherwise specified) less than or equal to greater than or equal to>
10 max m ax m ax m ax m ax
> 10-24 max
(a) (b) m in
48 min
24 max m in m in m in
24 max
18 min
18 min45° centered on tactile charactersLC m in
MEN not in pictogram field
AREA OF
REFUGE
3/8 min
3/8 min
LIBRARY
/8 m in m ax m ax at lavatory or counter m ax not at lavatory or counter full height (preferred)
Dimensions shown are from finished floor to bottom of reflective surface, unless noted otherwise m in (f in . f lr.
to to p ed ge
REFUGE
AREA OF
AREA OF
REFUGE
m in m ax
CHANGES IN LEVEL
NOTES REGARDING THE IMAGES SHOWN ON SHEETS A.010,
A.011 AND A.012:
1. ALL DETAILS REFERENCED ON THIS SHEET ARE TAKEN FROM
THE FLORIDA ACCESSIBILITY CODE 7th EDITION (2020) AND
APPLY TO ALL SHEETS, DRAWINGS AND DETAILS WITHIN
THESE CONSTRUCTION DOCUMENTS, WHETHER
SPECIFICALLY NOTED OR NOT
2. ALL DETAILS SHOWN ON THIS SHEET MAY NOT BE
APPLICABLE TO ALL PROJECTS
3. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS, NEW AND
EXISTING
4. ANY AND ALL DISCREPANCIES AND/OR QUESTIONS SHALL BE
PRESENTED TO THE ARCHITECT IN WRITING
TOE CLEARANCE
KNEE CLEARANCE
VERTICAL CLEARANCE
NOTESOBSTRUCTED HIGH FORWARD REACH
GRAPHIC CONVENTION FIGURE KEY
21 T-SHAPED TURNING SPACE
OBSTRUCTED HIGH SIDE REACH
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
PICTOGRAM FIELD
HEIGHT OF RAISED CHARACTERS
POSITION OF BRAILLE
MIRRORS
1/2" max
CARPET PILE
HEIGHT
1/4"
VERTICAL
CHANGE IN
LEVEL
1/4"
1/4"
1/2"
BEVELED
CHANGE IN
LEVEL
UNOBSTRUCTED
SIDE REACH
UNOBSTRUCTED
FORWARD REACH
HEIGHT OF TACTILE CHARACTERS ABOVE
FINISH FLOOR OR GROUND
15LOCATION OF TACTILE
SIGNS AT DOORS
LIMITS OF PROTRUDING
OBJECTS
EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2 inch (13 mm) minimum.
m ax m ax
INSTALL HEGIHT FOR SWITCHES,
KEY READERS, AND THERMOSTATS 17
distance between corresponding dots in adjacent cells distance between dots in the same cell distance between corresponding from one cell directly below distance between dots in the same cell single braille cell blank cell space between words base diameter raised dot
Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements.
19BRAILLE DIMENSIONS
no raised dot
MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES
Dot base diameter
Distance between two dots in the same cell
Distance between corresponding dots in adjacent cells
Dot height
Distance between corresponding dots from one cell directly below
0.059 (1.5 mm) to 0.063 (1.6 mm)
0.090 (2.3 mm) to 0.100 (2.5 mm)
0.241 (6.1 mm) to 0.300 (7.6 mm)
0.025 (0.6 mm) to 0.037 (0.9 mm)
0.395 (10 mm) to 0.400 (10.2 mm)
SHEET ISSUE
ACCESSIBILITY
DETAILS
01G.010
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
42 min m in
X < 48
42 min
X < 48
36 min 36 min m in
(a) 180 degree turn
(b) 180 degree turn (Exception)
(c) folding door
(a) hinged door
(b) sliding door
32 min
32 min
32 min m in
18 min
(a) front approach, pull side m in
(b) front approach, push side m in12 min
(c) front approach, push side, door provided with both closer and latch
36 min 60 m in
(d) hinge approach, pull side
42 min 54 m in
(e) hinge approach, pull side m in
22 min
(f) hinge approach, push side
(g) hinge approach, push side, door provided with both closer and latch m in
22 min
24 min m in
(h) latch approach, pull side
(i) latch approach, pull side, door provided with closer m in
24 min
24 min m in
(j) latch approach, push side
(k) latch approach, push side, door provided with closer
24 min m in m in
(a) front approach
(b) side approach m in
22 min m in
(c) pocket or hinge approach
24 min m in
(d) stop or latch approach
48 min 48 min
(a) (b)
48 min
(c)
0104 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATESMANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
CLEAR WIDTH AT TURN CLEAR WIDTH OF DOORWAYS
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS m in
18 min
X > 8
(a) pull side m in
(b) push side
X > 8 m in
12 min
(c) push side, door provided with both closer and latch
X > 8
DOORS IN SEQUENCE
SHEET ISSUE
ACCESSIBILITY
DETAILS
01G.012
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
NOTE:
THIS PARTITION OFTEN OCCURS IN MIRRORED PAIRS, FORMING
PLUMBING CHASES OR ARCHITECTURAL ELEMENTS. SEE THE PLANS
FOR DIMENSIONS OF SEPARATION.
STC RATED PARTITION CONSTRUCTED SOUND TESTED PER RAL-TL90-166
(THIS PARTITION IS NOT "FIRE RATED" FOR EGRESS)
GENERAL NOTES FOR ALL PARTITION TYPES:
1. KMF ARCHITECTS TYPICAL PARTITION TYPES
SHOWN. ALL PARTITIONS MAY NOT OCCUR
ON EVERY PROJECT. REFER TO PLAN AND
SECTION SHEETS.
2. SEE UL DETAILS INCLUDED AND OR
REFERENCED FOR FIRE RATED ASSEMBLY
REQUIREMENTS.
3. USE TILE BACKER BOARD BEHIND ALL TILE
WALLS & CEILINGS.
4. GYPSUM FINISH:
(UNLESS OTHERWISE NOTED)
LEVEL 5 TYP. @ ALL SPACES
LEVEL 4 TYP. @ STORAGE SPACES
LEVEL 3 TYP. @ MECHANICAL &
ELECTRICAL SPACES
5. PAINT ONE COAT TINTED PRIMER, TWO TOP
COATS MINIMUM. SEE SPECIFICATIONS.
6. ALL RATED PARTITIONS WITH INTERSECTING
CEILINGS & PARTITIONS IN OPEN STORAGE,
MECHANICAL & ELECTRICAL ROOMS SHALL
BE STENCILED PER CODE, INCLUDING FIRE
RATING, AND PROTECT ALL OPENINGS.
CEILING
HEAD
FILL FLUTES WITH SOUND ATTENUATION
BLANKETS OR MINERAL WOOL
CONT. STEEL CHANNEL TRACK, (20 GA MIN)
3 1/2" BATT INSULATION
SOUND ATTENUATION BATTS FULL HEIGHT OF WALL
5/8" GYP. BOARD ONE SIDE, FINISH AS SCHEDULED.
METAL RUNNER (20 GAUGE MIN.)
ANCHOR @ 24" O.C. MAX.
BASE AS SCHEDULED
METAL RUNNER (20 GAUGE MIN) ANCHOR
@ 24" O.C. MAX.
BASE EACH SIDE AS SCHEDULED.
CEILING AS SCHEDULED
5/8" GYP. BD. EACH SIDE, FINISH AS SCHEDULED
UNDERSIDE OF STRUCTURE.
CEILING
BASE
HEAD
METAL RUNNER (20 GAUGE MIN)
ANCHOR @ 24" O.C. MAX.
CONTINUOUS SEALANT EACH SIDE
5/8" GYP. BD. EACH SIDE, FINISH AS
SCHEDULED.
UNDERSIDE OF STRUCTURE.
BRACE TO STRUCTURE ABOVE @ 4'
O.C. STAGGER BRACES SIDE TO SIDE.
METAL RUNNER (20 GA. MIN.)
CEILING AS SCHEDULED
CEILING/HEAD
PLAN
BASE
BASE EACH SIDE AS SCHEDULED.
METAL RUNNER (20 GAUGE MIN).
ANCHOR @ 24" O.C. MAX.
CEILING
BASE
CEILING AS SCHEDULED
UNDERSIDE OF STRUCTURE ABOVE
PROVIDE INSULATION BATTS CONTINUOUS TO
UNDERSIDE OF STRUCTURE ABOVE
3 5/8" METAL STUDS (20 GA. MIN)
AT CEILING
UNDERSIDE OF STRUCTURE
CONT. STEEL CHANNEL TRACK, (20 GA MIN)
CEILING AS SCHEDULED
CONT. HORIZONTAL STUD BRACING AT CEILING
HEIGHT (20 GA. MIN)
METAL RUNNER (20 GAUGE MIN)
ANCHOR @ 24" O.C. MAX.
BASE AS SCHEDULED
BRACE TO STRUCTURE ABOVE @ 4' O.C.
STAGGER BRACES SIDE TO SIDE.
5/8" GYP. BOARD, FINISH AS SCHEDULED.
4" M
IN
HEAD
CEILING
I N T E R I O R R O O M S I D E
S H A F T
UNDERSIDE OF STRUCTURE
METAL RUNNER (20 GAUGE MIN)
ANCHOR @ 24" O.C. MAX.
PROVIDE FIRE-RATED HEAD OF WALL DETAIL AT
INTERSECTION WITH STRUCTURE ABOVE
CEILING AS SCHEDULED
PROVIDE FIRE-RATED BOTTOM OF WALL DETAIL AT
WALL INTERSECTION WITH STRUCTURE.
BASE AS SCHEDULED
(1) LAYER 1" TYPE "X" GYPSUM SHAFT SIDE
METAL RUNNER (20 GAUGE MIN) ANCHOR
@ 24" O.C. MAX.
CEILING
UNDERSIDE OF STRUCTURE
FILL FLUTES WITH SOUND ATTENUATION BLANKETS
OR MINERAL WOOL
METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24" O.C.
MAX.
3 1/2" BATT INSULATION, BOTH SIDES OF PARTITION
CEILING AS SCHEDULED
METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24" O.C.
MAX.
BASE EACH SIDE AS SCHEDULED
CONT. ACOUSTICAL SEALANT
5/8" TYPE C GYP. BOARD OVER 25 GA.
RESILIENT FURRING CHANNELS INSTALLED
HORIZONTALLY @ 24" O.C.
METAL RUNNER (20 GA. MIN.)ANCHOR
@ 24" O.C. MAX.
FILL IN FLUTES WITH FIRE SAFING; APPLY SMOKE
SEALANT. (PER UL HEAD OF WALL REQUIREMENT)
UNDERSIDE OF STRUCTURE.
5/8" TYPE 'X' GYPSUM BOARD EACH
SIDE OF METAL STUDS
CEILING AS SCHEDULED
FIRESTOP SEALANT
METAL RUNNER (20 GAUGE MIN.)
ANCHOR @ 24" O.C. MAX.
HEAD
BASE
4" M
IN
CONT. HORIZONTAL STUD BRACING AT CEILING
HEIGHT (20 GA. MIN)
CEILING AS SCHEDULED
CONT. HORIZONTAL STUD BRACING AT CEILING
HEIGHT (20 GA. MIN)
2'-0" TYP.
BASE EACH SIDE AS SCHEDULED
FIRE STOP SEALANT BOTH SIDES
METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24" O.C.
MAX.
BASE
BASE
BASE
BASE
2'-0"
TYP.
NOTE:
THIS PARTITION OFTEN OCCURS IN MIRRORED PAIRS,
FORMING PLUMBING CHASES OR ARCHITECTURAL ELEMENTS.
SEE THE PLANS FOR DIMENSIONS OF SEPARATION.
EXTEND FIRE RATING TO UNDERSIDE
OF STRUCTURE
BASE EACH SIDE AS SCHEDULED
PLAN
PLAN
SOUND ATTENUATION BATTS FULL
HEIGHT OF WALL
PLAN
2 LAYERS 5/8" TYPE 'X' GYPSUM BOARD EACH SIDE
OF METAL STUDS
3-5/8'' 20 GAGE METAL STUDS @ 16" O.C.
CEILING
HEAD
PLAN
3 5/8" STEEL STUDS (20 GA. MIN) @ 16" O.C. MAX.
DOUBLE STUDS AT ALL WALL HUNG MILLWORK,
TOILET PARTITIONS & ACCESSORIES, CASE
WORK & EQUIPMENT.
SHEET METAL BLOCKING (12 GA. MIN) SIZED
2" LARGER EACH DIRECTION THAN DIM. OF
WALL HUNG EQUIPMENT
CEILING/HEAD
3 5/8" STEEL STUDS (20 GA. MIN) AT 16" O.C. MAX.
DOUBLE STUDS AT ALL WALL HUNG MILLWORK,
TOILET PARTITIONS & ACCESSORIES,CASE WORK
& EQUIPMENT
SHEET METAL BLOCKING (12 GA. MIN) SIZED 2"
LARGER EACH DIRECTION THAN DIM. OF WALL
HUNG DEVICE
PLAN
PLAN
5/8" TYPE 'X' GWB ONE SIDE
2-1/2" C-H STUDS, PROVIDE GAUGE AS REQUIRED
FOR CONDITIONS WHERE INSTALLED
1-1/2" BATT INSULATION
PLAN
3 5/8" STEEL STUDS (20 GA. MIN.) @ 24" O.C.
3 1/2" SOUND ATTENUATION BATTS
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK, AND EQUIPMENT.
SEAL PENETRATIONS AT MILLWORK.
HEAD2'-0"
TYP.
METAL RUNNER (20 GAUGE MIN.)
ANCHOR @ 24" O.C. MAX.
BASE EACH SIDE AS SCHEDULED.
2 1/2" METAL STUDS (20 GA. MIN) AT
16" OC MAX.
CEILING AS SCHEDULED
5/8" GYP. BD. FINISH AS SCHEDULED.
UNDERSIDE OF STRUCTURE.
METAL RUNNER (20 GA. MIN.)ANCHOR
@ 24" O.C. MAX.
METAL DEFLECTION TRACK WITH 3"
FLANGES.
PLAN
3/
4" M
IN
CEILING
BASE
HEAD
METAL RUNNER (20 GAUGE MIN) ANCHOR @
24" O.C. MAX.
FILL IN FLUTES WITH FIRE SAFING. APPLY
SEALANT EACH SIDE.
UNDERSIDE OF STRUCTURE
5/8" GYP. BD. EACH SIDE, FINISH AS
SCHEDULED
CEILING AS SCHEDULED
BASE EACH SIDE AS SCHEDULED
METAL RUNNER (20 GAUGE MIN)
ANCHOR @ 24" O.C. MAX.
HEAD
CEILING
BASE
PLAN
3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK AND EQUIPMENT
3 5/8" METAL STUDS (20 GA. MIN.)
AT 16" O.C. MAX.
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK, AND EQUIPMENT
3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK, AND EQUIPMENT
3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.
3. FOR FIRE RATED PARTITIONS, PROVIDE UL LISTED HEAD OF WALL
CLOSURE TO MATCH RATING OF WALL OR GREATER.
2. FOR ALL PARTITIONS PARALLEL TO DECK FLUTES, CLOSE FLUTES
ABOVE WALLS WITH CONTINUOUS GALVANIZED 18 GAGE SHEET
METAL CLOSURE.
4. FOR SOUND ATTENUATION & MOISTURE CONTROL PARTITIONS,
PROVIDE CONTINUOUS ACOUSTICAL SEALANT. FOR ALL OTHER
PARTITIONS, PROVIDE TYPE 4 SEALANT: (1 PART ACRYLIC LATEX
TYPE, ASTM C 834).
1. FOR SOUND ATTENUATION PARTITIONS, PACK FLUTES FULL WITH
SOUND ATTENUATION INSULATION.
FOR RATED PARTITIONS, PACK FLUTES FULL WITH FIRE SAFING
INSULATION.
FOR THERMAL PARTITIONS, PACK FLUTES FULL WITH SEMI-RIGID
INSULATION, TYPE 1.
FOR ALL OTHER CONDITIONS, CLOSE DECK OFF WITH NEOPRENE &
SEAL EDGES
PARTITION PERPENDICULAR
TO METAL DECK FLUTES
PARTITION PARALLEL TO
METAL DECK FLUTES
3-1/8"
N O
N -R
AT
ED
W
AL
L R
AT
ED
W
AL
L
CONTROL JOINT.
DISTANCE
BETWEEN JOINTS
30'-0" O.C. MAX
GYPSUM WALLBOARD
ON METAL STUDS-
REFER TO PLANS FOR
PARTITION TYPES.
BACKER ROD &
ACOUSTICAL SEALANT @
WALLS W/ ACOUSTICAL
INSULATION ONLY.
JOINT COMPOUND-
FEATHER OUT MIN. 12"
FROM CONTROL JOINT.
(LEVEL 4 FINISH)
SKIM ENTIRE SURFACE
(LEVEL 5 FINISH)
5/8"
1/2"
MAX.
C LL C
JOINT COMPOUND-
FEATHER OUT MIN. 12"
FROM CONTROL JOINT.
CONTROL JOINT.
GYPSUM WALLBOARD
ON METAL STUDS-
REFER TO PLANS FOR
PARTITION TYPES.
ACOUSTIC SEALANT EACH SIDE
PROVIDE INSULATION BATTS CONTINUOUS TO
UNDERSIDE OF STRUCTURE ABOVE
HEAD
CEILING
I N T E R I O R R O O M S I D E
S H A F T
UNDERSIDE OF STRUCTURE
METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24"
O.C. MAX.
PROVIDE FIRE-RATED HEAD OF WALL DETAIL AT
INTERSECTION WITH STRUCTURE ABOVE
CEILING AS SCHEDULED
PROVIDE FIRE-RATED BOTTOM OF WALL DETAIL AT
WALL INTERSECTION WITH STRUCTURE.
BASE AS SCHEDULED
(1) LAYER 1" TYPE "X" GYPSUM SHAFT SIDE
METAL RUNNER (20 GAUGE MIN) ANCHOR @
24" O.C. MAX.BASE
PLAN
(2) LAYERS 5/8" TYPE 'X' GYP. BD. ONE SIDE
2-1/2" C-H STUDS, PROVIDE GAUGE AS REQUIRED
FOR CONDITIONS WHERE INSTALLED
1-1/2" BATT INSULATION
APPLY SAFING AT TOP OF GYPSUM BOARD
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK AND EQUIPMENT
DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK AND EQUIPMENT
UNDERSIDE OF STRUCTURE.
METAL RUNNER (20 GA. MIN.)ANCHOR
@ 24" O.C. MAX.
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK AND EQUIPMENT
SHEET METAL BLOCKING (12 GA. MIN) SIZED 2"
LARGER EACH DIRECTION THAN DIM. OF WALL
HUNG EQUIPMENT
FILL IN FLUTES WITH FIRE SAFING. APPLY SMOKE
SEALANT. (PER UL HEAD OF WALL REQUIREMENTS.)
(2) LAYERS 5/8" TYPE "X" GYPSUM SHAFT SIDE
5/8" GYP. BD. EACH SIDE. FINISH AS SCHEDULED
UNDERSIDE OF STRUCTURE
METAL RUNNER (20 GA. MIN.)
CEILING AS SCHEDULED
CEILING/HEAD
BASE
BASE EACH SIDE AS SCHEDULED
METAL RUNNER (20 GAUGE MIN) ANCHOR
@ 24" O.C. MAX.
BRACE TO STRUCTURE ABOVE @ 4' O.C.
STAGGER BRACES SIDE TO SIDE.
2'-0"
TYP.
SOUND ATTENUATION BATTS
4" M
IN
2'-0"
TYP.
PLAN
3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.
20 GA. DOUBLE STUDS @ ALL WALL HUNG
MILLWORK, CASE WORK, AND EQUIPMENT
3 1/2" SOUND ATTENUATION BATTS
SOUND ATTENUATION BLANKET
WHERE SCHEDULED
SOUND ATTENUATION BLANKET
WHERE SCHEDULED
CONTINUOUS SEALANT EACH SIDE
FILL IN FLUTES WITH FIRE SAFING; APPLY SMOKE
SEALANT. (PER UL HEAD OF WALL REQUIREMENT)
NOTE: PROVIDE DEFLECTION CHANNEL WHERE REQUIRED.
NOTE: PROVIDE DEFLECTION CHANNEL WHERE REQUIRED.
2 1/2" METAL STUDS (20 GA. MIN) AT
16" OC MAX.
FILL IN FLUTES WITH FIRE SAFING. APPLY SMOKE
SEALANT. (PER UL HEAD OF WALL REQUIREMENTS.)GYPSUM CUT WIDTH OF
STUD FOR SNUG FIT.
PLAN
CEILING
EXISTING WALL
HEAD
METAL WALL PANEL
CEILING AS SCHEDULED
METAL WALL PANEL
UNDERSIDE OF STRUCTURE.
METAL RUNNER (20 GAUGE MIN)
ANCHOR @ 24" O.C. MAX.
CONTINUOUS SEALANT
5/8" GYPSUM BOARD
2 1/2" METAL STUDS
BASE
ACCESS FLOOR SYSTEM
BASE AS SCHEDULED.
ANCHOR PER MANUF.
RECOMMENDATION
METAL WALL PANEL
UNDERSIDE OF DECK CONDITIONS
PLAN DETAIL - SOUND PARTITION
CONTROL JOINT DETAIL
A
N.T.S.
N.T.S.
Y
Y
X
PARTITION BETWEEN TAGS
WILL BE CONSTRUCTED AS
SHOWN ON PARTITION TYPE
SHEETS RESPECTIVELY TO
TYPE INDICATED.
PARTITION TYPE TAG
INDICATES PARTITION TYPE
AND DIRECTION UNTIL THE
END OF THE PARTITION OR A
NEW TAG OCCURS.
PARTITION
Z
X
N.T.S. APARTITION TYPE
NON-RATED
B
C
D
N.T.S. BPARTITION TYPE
NON RATED W/ SOUND REDUCTION
N.T.S. CPARTITION TYPE
NON RATED (ACOUSTIC DAMPING)
N.T.S. DPARTITION TYPE
NON-RATED
N.T.S. EPARTITION TYPE
PARTITION TYPE 1-HR RATED (UL #U465)
E
N.T.S. FPARTITION TYPE
PARTITION TYPE 2-HR RATED (UL #U411)
F
G
N.T.S. GPARTITION TYPE
51 STC RATED - RAL-TL-90-166 - SA 860620 - UL465
H
N.T.S. HPARTITION TYPE
N.T.S. JPARTITION TYPE
N.T.S. KPARTITION TYPE
J
K
N.T.S. LPARTITION TYPE
1-HOUR FIRE RATED SHAFT WALL (PER UL # U469)
L
N.T.S. MPARTITION TYPE
2-HOUR FIRE RATED SHAFT WALL (PER UL # U428)
M
GENERAL NOTES
PLAN DETAIL - FIRE RATED PARTITION
CONTROL JOINT DETAIL
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
N.T.S. NPARTITION TYPE
SHEET ISSUE
TYPICAL
PARTITION
TYPES
01G.100
N.T.S.
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
SHEET ISSUE
UL DETAILS
01G.200
ENTRANCE
EMERGENCY
OPERATIONS CENTER
CORR.
CORR.
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
BREAK
ROOM
IT / CONTROL
ROOM
CONFERENCE
ROOM
151A
COPY
CENTER
151C
STORAGE
151B
ADMIN.
OPERATIONS
151D
LOBBY
RECEPTION
BREAKOUT A
143A
BREAKOUT B
143B
'-1
0"
CORRIDOR
STORAGE
151E
VESTIBULE
128A
'-4
VEST.
141A
SHEET ISSUE
LIFE
SAFETY PLAN
01LS.10101PARTIAL FLOOR PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
MOBILE
SPEAKER
PODIUM
MOBILE
SEATING
TABLES FOR
RAMP
RAMP
EX
IT
S
EP
AR
AT
IO
N
T O
B E
'-1
" M
IN
1/
O
F R
O O
M D
IA
G
O N
AL
'-4
" F T.
EXIT LIGHT (ARROW INDICATES TRAVEL DIRECTIONAL ARROW), SEE
ELECTRICAL PLAN (EX = EXISTINGTO REMAIN WHERE SHOWN ON PLANS)
EMERGENCY LIGHT / NIGHT LIGHT FIXTURES
EGRESS CAPACITY OF
EXIT COMPONENT (IN
PERSONS)
EX = EXISTING
EXISTING FIRE EXTINGUISHER AND/OR CABINET
(EX = EXISTING TO REMAIN WHERE SHOWN ON PLAN)
FE
DOOR
EXIT COMPONENT
MEANS OF EGRESS DOORS SHALL PROVIDE A
MINIMUM WIDTH OF 32 INCHES (PER DOOR) WITH
THE DOOR OPEN 90 DEGREES, MEASURED
BETWEEN THE FACE OF THE DOOR AND THE
OPPOSITE STOP AS REQUIRED BY 11-4.13.5
FLORIDA ACCESSIBILITY CODE FOR BUILDING
CONSTRUCTION, FBC 2020, AND 7.2.1.2.2, NFPA 101.
EX
EX
LIFE SAFETY LEGEND
COMMON PATH OF EGRESS TRAVEL (W/ INDICATED DISTANCE)
00'
3'-6"* INDICATES WIDTH OF EGRESS PATH AT EACH INTERNAL SEGMENT
(BASED ON CURRENT FURNISHINGS LAYOUT)
RELOCATED EMERGENCY LIGHT LOCATION SHOWN ON LIFE
SAFETY & REFLECTED CEILING PLANS; INDICATED W/ TAG 'ER'
** REFER TO NOTE AT BUILDING CODE ANALYSIS REGARDING EXISTING EGRESS
PATH OF TRAVEL TO REMAIN UNCHANGED & THEREFORE NOT DELINEATED IN
THESE PLANS.
MAXIMUM PATH OF EGRESS TRAVEL (W/ INDICATED DISTANCE)
00'
ROOM AREA
OCC. LOAD FACTOR
OCCUPANT LOAD
REQUIRED EXIT WIDTH
# IN
BUSINESS OCCUPANCY
100 SF/ PERS
SMALL ASSEMBLY -
UNCONCENTRATED
15 SF/ PERS
OCCUPANT LOAD
BASED ON TABLE 1004.1.2 & NFPA 7.3.1.2
FUNCTION OF SPACE AREA PER
OCCUPANT
TOTAL OCCUPANTS
EGRESS WIDTH
TABLE 1005.1 & NFPA 101-7.3.3.1
ROOM OCC.
TYPE
TOTAL
OCCUPANCY
REQUIRED EGRESS WIDTH
STAIRWAYS (INCHES) OTHER EGRESS
COMPONENTS (INCHES)
PROVIDED EGRESS WIDTH
STAIRWAYS (INCHES) EGRESS DOORWAYS
(INCHES)
EGRESS ACCESS TRAVEL DISTANCE
TABLE 1016.1 & NFPA 101-38.2.6.2
FLOOR OCCUPANCY
TYPE
ALLOWABLE EXIT ACCESS
TRAVEL DISTANCE (IN FEET)
ACTUAL MAXIMUM EXIT ACCESS
TRAVEL DISTANCE (IN FEET)
COMMON PATH OF EGRESS TRAVEL
TABLE 1014.3 & NFPA 101-39.2.5.3.3
FLOOR OCCUPANCY
TYPE
ALLOWABLE COMMON PATH OF
TRAVEL DISTANCE (IN FEET)
ACTUAL MAXIMUM COMMON PATH OF
TRAVEL DISTANCE (IN FEET)
DEAD END CORRIDOR REQUIREMENTS
SECTION 1018.4 & NFPA 101-39.2.5.2
FLOOR OCCUPANCY
TYPE
ALLOWABLE DEAD END CORRIDOR
DISTANCE (IN FEET)
ACTUAL MAXIMUM DEAD END
CORRIDOR DISTANCE (IN FEET)
100 7 OCCUPANTSGROUP-B
BUSINESS
254 0.2" (254) = 51 64N/A N/AALL BUSINESS
1 200BUSINESS 122
1 100BUSINESS 46
1 20 N/ABUSINESS
15 246 OCCUPANTSGROUP-B
SMALL ASSEMBLY
300 1 OCCUPANTSSTORAGE
254 OCCUPANTS
RENOVATED AREA
TOTAL
EXIT WIDTH
EXIT CAPACITY
2,352
32 IN
1 @ 32"
2"
4 IN
4 IN
4 IN
0.4 IN
1. EXISTING BUILDING IS TYPE IV, FULLY SPRINKLERED
NO CHANGES TO USE OR OCCUPANCY
2. LEVEL 2 ALTERATION
LIFE SAFETY NOTES
1.8 IN
1.8 IN
60'-2"
69'-2"
0.2 IN
0.8 IN
122 '
STORAGE OCCUPANCY
300 SF/ PERS
NO WORK
THIS AREA
FE
AED
EXISTING AUTOMATED EXTERNAL DEFIBRILLATOR AND/OR CABINET
(EX = EXISTING TO REMAIN WHERE SHOWN ON PLAN)EXAED
0.2 IN
3.0 IN
RELOCATED
EXISTING
EXTERNAL
DEFIBRILLATOR
FE
EXISTING
ONE-HOUR
RATED WALL
NEW ONE-HOUR
RATED WALL
EXISTING ONE HOUR RATED WALL
NEW ONE HOUR RATED WALL
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
6FT
OPERATIONS CENTER
MESSAGE
CENTER
GIS
CENTER
145B
PIO
CENTER
145A
CORR.
HAM
RADIO
CORR.
LOBBY
BREAK
ROOM
IT / CONTROL
ROOM
CONFERENCE
ROOM
151A
ADMIN.
OPERATIONS
151D
STORAGE
151C
COPY
CENTER
151B
CORR.
BREAKOUT A
143A
BREAKOUT B
143B
RECP.
VESTIBULE
128A
STORAGE
151E
VEST.
141A
GENERAL NOTES
SHEET ISSUE
OVERALL
FLOOR PLAN
01A.10001OVERALL FLOOR PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
NO WORK
THIS AREA
HATCH INDICATES
NOT IS SCOPE
A.101
AD.101
EAST
COVERED
ENTRY
NORTH
COVERED
ENTRY
WEST
COVERED
ENTRY
SOUTH
COVERED
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/8"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
12FT
OPERATIONS CENTER
CORR.
CLOSET
151D
ENTRANCE
OPERATIONS
DESK
151C
EOC
CONTROL
151B
COPY
CENTER
151A
IT EQUIP.
ROOM
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
CLOSET
151E
VEST.
128A
CORRIDOR
3' -9
7 3/4"
5'-0" 5'-4 1/2"
GENERAL NOTES
SHEET ISSUE
PARTIAL
DEMOLITION
PLAN
01AD.10101PARTIAL DEMOLITION PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
D01 EXISTING WALL TO BE REMOVED
D02 EXISTING DOOR AND FRAME TO BE
REMOVED
D03 EXISTING MILLWORK TO BE REMOVED
D04 EXISTING PLAN TABLES TO BE REMOVED
D05 EXISTING RAISED FLOOR TO BE REMOVED
D06 EXISTING SYSTEMS FURNITURE TO BE
REMOVED
D07 EXISTING SERVERS TO BE REMOVED;
RETURN TO OWNER FOR DISPOSITION
D08 RETURN ALL CHAIRS TO OWNER
D09 RETURN ALL EXISTING TECH. TO OWNER
D10 REMOVE EXISTING FLOORING AND BASE;
PREP FOR NEW FLOORING AND BASE;
PATCH AND LEVEL
D11 REMOVE EXISTING RAMP AND ASSOCIATED
RAILING
D12 EXISTING AED TO BE REMOVED AND
RE-INSTALLED AS DIRECTED BY OWNER
D13 REMOVE EXISTING POWER POLE
D14 REMOVE EXISTING WHITE BOARD
D15 EXISTING COLUMN TO REMAIN
D16 REMOVE EXISTNG GLAZING AND FRAME
D17 PROTECT EXISTING DOORS, TYPICAL
D18 PROTECT ELEVATOR DOORS, FRAME, CAB,
AND CONTROLS
D19 EXISTING DISPLAY CASE TO BE RELOCATED
DEMOLITION FLOOR PLAN - KEY NOTESDXX
D04
D01
D02
D03
NO WORK
THIS AREA
NO WORK
THIS AREA
NO WORK
THIS AREA
D05
D01
D06
D01
D01
D01
D02
AD.401
3D
2D
4D
1D
D07
TYP.
D01
D02
D02
D01
D05
TYP.
D11
D02
D08
TYP.
D11
D10
D10
D02
D02
D02
D10
AD.401
7D
6D
8D
5D
D12
D15
D14
D13
D08
TYP.
D04
TYP.
D03
D10
D16
D08
D04
D04
D08
D04
D08
D15
D16
D17
D10
D17
D10D17
D18
AD.402
3D
2D
4D
1D
D19
D08
D04
D06
D08
D08
D01
D08
D03
AD.402
6D
5D
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text s s s s s s s s s s s s s s s s s s s s s
EMERGENCY
OPERATIONS CENTER
CORR.
CLOSET
151D
ENTRANCE
OPERATIONS
DESK
151C
EOC
CONTROL
151B
COPY
CENTER
151A
IT EQUIP.
ROOM
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
CLOSET
151E
VEST.
128A
GENERAL NOTES
SHEET ISSUE
PARTIAL DEMO.
REFLECTED
CEILING PLAN
01AD.11101PARTIAL DEMO. REFLECTED CEILING PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
DEMOLITION REFLECTED CEILING PLAN -
KEY NOTESDXX
D01 REMOVE EXISTING CEILING TILE & GRID
D02 REMOVE EXISTING LIGHTING
D03 REMOVE EXITING MECHANICAL DIFFUSER
D04 REMOVE EXISTING TRACK LIGHTING
D05 REMOVE EXISTING CEILING MOUNTED
PROJECTOR; RETURN TO OWNER
D06 REMOVE EXISTING SPEAKER
D07 EMERGENCY LIGHTING TO REMAIN (TYP)
D04
D05
D01
D02 D03
D02
D03
D02
NO WORK
THIS AREA
NO WORK
THIS AREA
NO WORK
THIS AREA
D01 D05
TYP.
TYP.
TYP.
D01
D02
D03
D05
D05
D06
D07
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
N.T.S. 3DROOM 151 INTERIOR ELEVATION - EAST
FOR REFERENCE ONLY
N.T.S. 2DROOM 151 INTERIOR ELEVATION - SOUTH
FOR REFERENCE ONLY
N.T.S. 1DROOM 151 INTERIOR ELEVATION - NORTH
FOR REFERENCE ONLY
N.T.S. 4DROOM 151 INTERIOR ELEVATION - WEST
FOR REFERENCE ONLY
N.T.S. 7DRECEPTION INTERIOR ELEVATION - EAST
FOR REFERENCE ONLY
N.T.S. 6DRECEPTION INTERIOR ELEVATION - SOUTH
FOR REFERENCE ONLY
N.T.S. 5DRECEPTION INTERIOR ELEVATION - NORTH
FOR REFERENCE ONLY
N.T.S. 8DRECEPTION INTERIOR ELEVATION - WEST
FOR REFERENCE ONLY
01 DEMO EXISTING WALL
02 DEMO EXISTING CEILING & PREP FOR NEW
03 DEMO EXISTING FLOORING & PREP FOR NEW
04 DEMO EXISTING MILLWORK
05 DEMO EXISTING DOOR & FRAME
06 DEMO EXISTING LIGHTING
07 REMOVE EXISTING PARTITION
08 REMOVE & STORE FOR RELOCATION
09 PREP SURFACE FOR NEW PAINT / FINISH
10 EXISTING RATED COLUMN ASSEMBLY
TO REMAIN
SOME NOTES MAY NOT APPLY ON ALL SHEETS
INTERIOR ELEVATION - DEMO NOTESXX
07 07
09 09
01 10
01 09
01 09
SHEET ISSUE
DEMO
ELEVATIONS
01AD.401
DOOR, SEE SCHEDULE
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
N.T.S. 1DELEVATOR LOBBY - NORTH
FOR REFERENCE ONLY
01 DEMO EXISTING WALL
02 DEMO EXISTING CEILING & PREP FOR NEW
03 DEMO EXISTING FLOORING & PREP FOR NEW
04 DEMO EXISTING MILLWORK
05 DEMO EXISTING DOOR & FRAME
06 DEMO EXISTING LIGHTING
07 REMOVE EXISTING PARTITION
08 REMOVE & STORE FOR RELOCATION
09 PREP SURFACE FOR NEW PAINT / FINISH
10 EXISTING RATED COLUMN ASSEMBLY
TO REMAIN
SOME NOTES MAY NOT APPLY ON ALL SHEETS
INTERIOR ELEVATION - DEMO NOTESXX
N.T.S. 2DELEVATOR LOBBY - EAST
FOR REFERENCE ONLY
N.T.S. 3DELEVATOR LOBBY - SOUTH
FOR REFERENCE ONLY
N.T.S. 4DELEVATOR LOBBY - WEST
FOR REFERENCE ONLY
N.T.S. 5DBREAK ROOM - WEST
FOR REFERENCE ONLY
N.T.S. 6DBREAK ROOM - EAST
FOR REFERENCE ONLY
SHEET ISSUE
DEMO
ELEVATIONS
01AD.402
OPERATIONS CENTER
CORR.
CORR.
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
BREAK
ROOM
IT / CONTROL
ROOM
CONFERENCE
ROOM
151A
COPY
CENTER
151C
STORAGE
151B
ADMIN.
OPERATIONS
151D
LOBBY
RECEPTION
BREAKOUT A
143A
BREAKOUT B
143B
128A
0A
1A
143A 143B
CORRIDOR
STORAGE
151E
VESTIBULE
128A
VEST.
141A
2' -8
13'-10" 7'-7" 5'-1 3/4" 13'-0" 11'-6" 5'-0" 10'-10 1/4"9'-10 1/4"
1A
1C
1B
1D
3' -6
'-7
/2
'-3
/2
2' -0
3'
-5
5'-0"6'-0 1/2"
9' -5
/4
9'-7" 9'-0 1/2" 9'-8"3'-8 1/4" 3'-4" 3'-8 1/2" 3'-8 1/2" 5'-4 1/4"
3' -5
/4
'-3
/4
'-1
3/
4" 3'
-4
2'-3 1/2" 5'-10 1/4"
4' -7
/4
GENERAL NOTES
SHEET ISSUE
PARTIAL
FLOOR PLAN
01A.10101PARTIAL FLOOR PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
01 NEW PARTITION
02 NEW DOOR AND FRAME
03 NEW GLASS SURFACE MEDIA WALL SYSTEM
ON ALUMINUM GRID
04 NEW MILLWORK
05 NEW MOBILE FURNITURE
06 NEW RAISED FLOOR
07 NEW BULLET-RESISTANT GLASS ENCLOSURE
08 NEW SLIDING DOOR
09 NEW 85" TV
10 NEW 45" TV ABOVE
11 NEW MEDIA WALL SYSTEM
12 NEW SERVER RACK. COORDINATE WITH
IT DRAWINGS
13 NEW ELECTRICAL PANEL
14 RELOCATED DISPLAY CASE
15 IT RACK CLEARANCE
16 NEW ADJUSTABLE SHELVING
17 NEW MEDIA WALL SYSTEM IN FRONT OF
EXISTING PARTITION
18 LOGO
19 COPIER
20 INFILL OPENING. SHALL BE TRUE AND FLUSH
WITH EXISTING WALL
21 STUB WALL. COORDINATE WITH MEDIA WALL
SYSTEM TO MATCH THICKNESS AND HIDE
SEAM.
22 RE-USE EXISTING FLOOR PENETRATIONS
ABOVE FOR WIRING TO 2nd FLOOR -
COORD. WITH TECHNOLOGY DRWGS. AND
OWNER
FLOOR PLAN - KEY NOTESXX
MOBILE
SPEAKER
PODIUM
RAMP
RAMP
NO WORK
THIS AREA
NO WORK
THIS AREA
NO WORK
THIS AREA
TYP.
A.401
ALIGN
TYP.
TYP.
04 07
TYP.
11 11
D
D
ED
A.402
A.402
A.403
A.401
A.403
AL
IG
N
A.340
A.340
A.340
D
E
A/ V
R
AC
KS
N
ET
W
O R
K R
AC
KS
A.351
A.351
A.351
A.602
ALIGN
D
D
D
A.603
09 09
N
D
NEW GYPSUM BOARD PARTITION
NEW MEDIA WALL
EXISTING TO REMAIN
WALL LEGEND
A.603
D
A.40405
A.603
N
A.340
A.340
A.603
AL
IG
N
ALIGN
ALIGN
ALIGN
D D
A.40408
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OPERATIONS CENTER
CORR.
CORR.
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
BREAK
ROOM
IT / CONTROL
ROOM
CONFERENCE
ROOM
151A
COPY
CENTER
151C
STORAGE
151B
ADMIN.
OPERATIONS
151D
LOBBY
101RECEPTION
BREAKOUT A
143A
BREAKOUT B
143B
CORRIDOR
STORAGE
151E
VESTIBULE
128A
VEST.
141A
6'-0" 5'-8"6'-0"13'-1 1/2"5'-8" 6'-0" 6'-0"
5'-8"6'-0"6'-0"13'-1 1/2"6'-0"
5'-8"6'-0"6'-0"13'-1 1/2"6'-0"11'-7 3/4"
5'-8"6'-0"6'-0"6'-0"6'-0"5'-7 3/4"
8'-9"2'-11"
6'-6 1/2"6'-6 1/2" 6'-3 1/2"6'-3 1/2"
'-5
'-5
/4
'-5
'-5
/4
8' -6
/2
'-0
'-0
'-0
6' -9
/4
6'-1 1/2" 7'-0"
4' -9
/2
'-8
GENERAL NOTES
SHEET ISSUE
ACCESS
FLOOR PLAN
01A.10201PARTIAL FLOOR PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
RAMP
RAMP
01 2' x 2' CARPET TILE ON ACCESS FLOOR
02 FLOOR BOX POWER AND DATA OUTLET
ACCESS FLOOR - KEY NOTESXX
NO WORK
THIS AREA
NO WORK
THIS AREA
NO WORK
THIS AREA
TYP.
02 02
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text s s s s s s s s s s s s s s s s s s s s
3' FIXTURE
2' FIXTURE
2' FIXTURE
2' F
IX
TU
R E
3' F
IX
TU
R E
3' F
IX
TU
R E
2' F
IX
TU
R E
3' F
IX
TU
R E
2' F
IX
TU
R E
2' F
IX
TU
R E
2' F
IX
TU
R E
2' FIXTURE
s s s s s s s s s s s s s s s s s s
EMERGENCY
OPERATIONS CENTER
CORR.
CORR.
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
BREAK
ROOM
IT / CONTROL
ROOM
CONFERENCE
ROOM
151A
COPY
CENTER
151C
STORAGE
151B
ADMIN.
OPERATIONS
151D
LOBBY
101RECEPTION
BREAKOUT A
143A
BREAKOUT B
143B
CORRIDOR
STORAGE
151E
VESTIBULE
128A
VEST.
141A
GENERAL NOTES
SHEET ISSUE
PARTIAL
REFLECTED
CEILING PLAN
01A.11101PARTIAL REFLECTED CEILING PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
REFLECTED CEILING PLAN - KEY NOTESXX
01 ACT CEILING
02 WOOD GRILLE CEILING
03 LINEAR METAL CEILING
04 GYPSUM BOARD CEILING
05 LIGHT FIXTURE
06 MECHANICAL DIFFUSER
07 LINEAR LED LIGHT FIXTURE 4'-0" IN
LENGTH UNLESS OTHERWISE NOTED
08 SLOT DIFFUSER
09 PTZ CAMERA
10 SPEAKER NEW OR EXISTING
11 PENDANT LIGHT FIXTURE
NO WORK
THIS AREA
NO WORK
THIS AREA
NO WORK
THIS AREA
TYP.
TYP.
02 07
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
A.602
A.602
FIN. CLG.
8'-8"
FIN. CLG.
9'-0"
FIN. CLG.
9'-0"
(MATCH
EXISTING)
FIN. CLG.
+8'-9"
A.602
A.602
A.602
NEW GYPSUM BOARD CEILING
NEW ACT CEILING
NEW WOOD GRILLE CEILING
NEW LINEAR METAL CEILING
CEILING LEGEND
A.341
FIN. CLG.
+8'-9"
FIN. CLG.
+8'-9"
FIN. CLG.
+9'-0"
(MATCH
EXISTING)
FIN. CLG.
9'-0"
(MATCH
EXISTING)
FIN. CLG.
+8'-9"
A.602
A.602
TYP.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text s s s s s s s s s s s s s s s s
3' FIXTURE
2' FIXTURE
2' FIXTURE
2' F
IX
TU
R E
3' F
IX
TU
R E
3' F
IX
TU
R E
2' F
IX
TU
R E
3' F
IX
TU
R E
2' F
IX
TU
R E
2' F
IX
TU
R E
2' F
IX
TU
R E
2' FIXTURE
2'-0" 2'-0" 2'-0" 2'-0" 2'-6 1/2" 2'-6 1/2" 2'-3 1/2" 2'-3 1/2"
2'-0" 2'-0" 2'-0" 2'-0"
2'-3" 11"1'-2" 3'-3" 2'-8" 1'-2"
2'-11" 4'-3" 5'-0" 4'-6" 4'-3" 4'-3" 4'-5" 3'-10" 5'-0" 2'-8" 4'-0"
9" 10" 8"
1'-2" 10"
2'-3" 1'-0"
1'-6"
1'-6"
1'-9"
1'-0"8"
6"
2'-0"
1'-1"
1'-10"
2'-3"
2'-8"
6"
3'-3"
1'-10
6"1'-9"
4' -7
5'-8" 12'-0" 12'-9" 11'-9 1/2" 6'-8"
4' -1
0"
'-0
'-0
'-6
6' -0
8'-0"
4' -3
/4
12"
6' -0
6'
-0
2'-5" 4'-10" s
1' -8
3'
-4
1' -8
1'
-8
1' -8
1'
-8
2'-7" 2'-7" 1'-1"
3'-9" 1'-5" 4'-0" 4'-0" 1'-7"
7'-1"
2' -3
3'-0"
4"
1' -5
1' -8
1' -8
1'-9"
6'-3"3'-3 1/2"9'-0"
1'-8 1/2"
2'-0" 2'-8 1/2"1'-8" 9 1/2" 2'-1" s s s s s s s s s s s s s s s s s
2' -3
/2
1' -1
1' -1
1" 2'
-1
1' -0
1'
-0
1' -7
6' -0
1' -7
1' -0
1'
-0 "4' -3
/4
5'
-0
5' -0
2'-7 1/4"
EMERGENCY
OPERATIONS CENTER
CORR.
CORR.
HAM
RADIO
MESSAGE
CENTER
PIO
CENTER
145A
GIS
CENTER
145B
BREAK
ROOM
IT / CONTROL
ROOM
144CONFERENCE
ROOM
151A
COPY
CENTER
151C
STORAGE
151B
ADMIN.
OPERATIONS
151D
LOBBY
RECEPTION
BREAKOUT A
143A
BREAKOUT B
143B
CORRIDOR
STORAGE
151E
VESTIBULE
128A
VEST.
141A
1' -7
9'
-1
2' -0
"11 '-3
2' -0
9'
-0
/4
1'-7"7'-7"
GENERAL NOTES
SHEET ISSUE
REFLECTED
CEILING
DIMENSION
PLAN
01A.11201REFLECTED CEILING DIMENSION PLAN
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
REFLECTED CEILING PLAN - KEY NOTESXX
01 ACT CEILING
02 WOOD GRILLE CEILING
03 LINEAR METAL CEILING
04 GYPSUM BOARD CEILING
05 LIGHT FIXTURE
06 MECHANICAL DIFFUSER
07 LINEAR LED LIGHT FIXTURE 4'-0" IN
LENGTH UNLESS OTHERWISE NOTED
08 SLOT DIFFUSER
09 PTZ CAMERA
10 SPEAKER NEW OR EXISTING
11 PENDANT LIGHT FIXTURE
NO WORK
THIS AREA
NO WORK
THIS AREA
NO WORK
THIS AREA
W O
O D
G R
IL
LE
C
EI
LI
N
G
WOOD GRILLE CEILING
AutoCAD SHX Text
SCALE
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
Floor
3"3"3"
3 3/4"
SHEET ISSUE
FLOOR AND
WALL SYSTEM
DETAILS
01A.340
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
01ACCESS FLOOR DETAILS
MEDIA WALL
SYSTEM -
BASIS OF DESIGN
"DIRTT" SYSTEM
TV MONITOR
WHERE SCHEDULED -
SEE FLOOR PLAN AND
INTERIOR ELEVATIONS
ACCESS FLOOR
SYSTEM -
BASIS OF DESIGN
"DIRTT" FLOOR
CEILING AS
SCHEDULED
0 1 FT6 IN 1 1/2 FT1"= 1'-0"
SCALE 02MEDIA WALL SECTION0 1 FT6 IN 1 1/2 FT1"= 1'-0"
SCALE 03MEDIA WALL SECTION0 1 FT6 IN 1 1/2 FT1"= 1'-0"
SCALE 04GLASS WALL SECTION
5/8" GYPSUM BOARD ON EACH
SIDE ON 3 5/8" METAL STUDS
AT 16" O.C. ( 25 GA. MIN. )
CONTINUOUS SEALANT
EACH SIDE
METAL RUNNER ( 20 GA.
MIN. ) ANCHOR AT 24"
O.C. MAX.
UNDERSIDE OF
STRUCTURE
TV MONITOR
WHERE SCHEDULED -
SEE FLOOR PLAN AND
INTERIOR ELEVATIONS
CEILING AS
SCHEDULED
5/8" GYPSUM BOARD ON
3 5/8" METAL STUDS AT
16" O.C. ( 25 GA. MIN. )
CONTINUOUS SEALANT
EACH SIDE
METAL RUNNER ( 20 GA.
MIN. ) ANCHOR AT 24"
O.C. MAX.
UNDERSIDE OF
STRUCTURE
EXISTING WALL
TO REMAIN
GLASS WALL
SYSTEM - WITH
SWITCHABLE
PRIVACY GLASS
CEILING AS
SCHEDULED
CONTINUOUS SEALANT
EACH SIDE
METAL RUNNER ( 20 GA.
MIN. ) ANCHOR AT 24"
O.C. MAX.
UNDERSIDE OF
STRUCTURE
SOUND ATTENUATION
BLANKETS
SOUND ATTENUATION
BLANKETS
5/8" GYPSUM BOARD ON EACH
SIDE ON 3 5/8" METAL STUDS
AT 16" O.C. ( 25 GA. MIN. )
MEDIA WALL
SYSTEM -
BASIS OF DESIGN
"DIRTT" SYSTEM
ACCESS FLOOR
SYSTEM -
BASIS OF DESIGN
"DIRTT" FLOOR
ACCESS FLOOR
SYSTEM -
BASIS OF DESIGN
"DIRTT" FLOOR
WALL SYSTEM
RAISED FLOOR
SYSTEM
POWER AND
DATA FEED
0 6 IN33"= 1'-0"
SCALE 05BASE DETAIL
0 6 IN33"= 1'-0"
SCALE 06WALL DETAIL
A.340
A.340
WALL SYSTEM
0 6 IN33"= 1'-0"
SCALE 07WALL DETAIL
0 6 IN33"= 1'-0"
SCALE 08HEAD DETAIL
A.340
EXISTING WALL
TO REMAIN
A.340
TV MONITOR
WHERE SCHEDULED -
SEE FLOOR PLAN AND
INTERIOR ELEVATIONS
WALL SYSTEM
PANEL JOINT -
SEE INTERIOR
ELEVATIONS FOR
LOCATIONS
A.341
A.341
WALL SYSTEM
PANEL JOINT
TV MONITOR
WHERE SCHEDULED -
SEE FLOOR PLAN AND
INTERIOR ELEVATIONS
CEILING AS
SCHEDULED
CEILING AS
SCHEDULED
EXISTING WALL TO
REMAIN
EXISTING WALL TO
REMAIN
5/8" GYPSUM BOARD ON
3 5/8" METAL STUDS AT
16" O.C. ( 25 GA. MIN. )
FIN CLG
+8'-9"
( MATCH
EXISTING )
FIN FLOOR
0'-0"
( MATCH
EXISTING )
FIN FLOOR
0'-0"
( MATCH
EXISTING )
FIN CLG
+8'-9"
( MATCH
EXISTING )
3"
SHEET ISSUE
FLOOR AND
WALL SYSTEM
DETAILS
01A.341
839 N. MAGNOLIA AVE.
ORLANDO, FL 32803
# AR93580
E
R
ES
C U
E
- E
O C
O R
AN
G
E C
O U
N
TY
G O
VE
R
N M
EN
T
IN
TE
R
IO
R A
LT
ER
AT
IO
N S
A M
O R
Y C
O U
R T
W
IN
TE
R
P
AR
K, F
LO
R
ID
A
PROJECT #:
DATE: 07.07.2021
190608
ERIC OSKAR KLEINSTEUBER
FLORIDA LICENSE # AR93580
RELEASE
BID AND PERMIT
NO. DATE
01 07.07.2021
0 6 IN33"= 1'-0"
SCALE 01BASE DETAIL GENERAL NOTES
0 6 IN33"= 1'-0"
SCALE 02HEAD DETAIL
FLOOR TILE
EXISTING CONCRETE
SLAB TO REMAIN
CEILING AS
SCHEDULED
GLASS WALL
SYSTEM - WITH
SWITCHABLE
PRIVACY GLASS
GLASS WALL
SYSTEM - WITH
SWITCHABLE
PRIVACY GLASS
STEEL SUPPORT
0 6 IN 1 FT
SCALE
1-1/2"= 1'-0" 06SECTION DETAIL
TV MONITOR
WHERE SCHEDULED -
SEE FLOOR PLAN AND
INTERIOR ELEVATIONS
TV MONITOR
WHERE SCHEDULED -
SEE FLOOR PLAN AND
INTERIOR ELEVATIONS
ACCESS FLOOR
SYSTEM -
BASIS OF DESIGN
"DIRTT" FLOOR
0 6 IN 1 FT
SCALE
1-1/2"= 1'-0" 05PLAN DETAIL
CEILING AS
SCHEDULED
WALL PANEL
SYSTEM
A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION
PURPOSES ONLY.
B. USE ONLY WRITTEN DIMENSIONS. DO NOT
SCALE DRAWINGS.
C. THE CONTRACTOR SHALL VERIFY ALL
CONDITIONS & DIMENSIONS ON-SITE PRIOR TO
COMMENCING WORK; ALL INQUIRIES & NOTED
DISCREPANCIES SHOULD BE DIRECTED IN
WRITING TO THE ARCHITECT PRIOR TO
PROCEEDING WITH THE WORK/AREA IN
QUESTION.
D. ALL DIMENSIONS ARE TO FINISH FACE OF
SURFACE INDICATED UNLESS OTHERWISE
NOTED (UON).
E. PROVIDE ALL WARNING AND EGRESS SIGNAGE
IN COMPLIANCE WITH FLORIDA BUILDING CODE
DURING AND AFTER CONSTRUCTION.
F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND
FIRE EXTINGUISHER CABINETS.
G. ALL MILLWORK TO BE FIELD MEASURED /
VERIFIED BEFORE FABRICATING.
H. CONTRACTOR TO REPAIR ALL WALLS
AFFECTED BY DEMOLITION & EQUIPMENT
REMOVAL TO MATCH THE EXISTING ADJACENT
WALL SURFACES.
I. REMOVE ALL MONITORS, COMPUTERS,
PROJECTORS AND EQUIPMENT. RETURN TO
OWNER.
GENERAL NOTES
FIN CLG
+8'-9"
( MATCH
EXISTING )
MEDIA WALL
SYSTEM
EXISTING WALL
TO REMAIN
DOUBLE PIVOT
DOORS
5/8" GYPSUM BOARD ON EACH
SIDE ON 3 5/8" METAL STUDS
AT 16" O.C. ( 25 GA. MIN. )
SOUND ATTENUATION
BLANKETS
FIN FLOOR
0'-0"
( MATCH
EXISTING )
0 6 IN 1 FT
SCALE
1-1/2"= 1'-0" 07SECTION DETAIL
TV MONITOR
WH…
This is the start of the file's text. The full file is on GovTribe.