Y22-7003-ZR_Drawings.pdf
PDF 29 MB Posted
- Attached to
- Force Main Lake Underhill at Chickasaw Trail
- Solicitation number
- Y22-7003-ZR
- Issued by
- Orange County, Orlando City, Florida
About this file
The document is a set of construction drawings for the Lake Underhill Force Main Replacement project by the Orange County Utilities Department, located in Orlando, Florida. The project involves replacing approximately 1,357 linear feet of existing force main pipeline using 16-inch and 12-inch PVC and HDPE pipes along Lake Underhill Road. The construction drawings, dated August 2021, provide detailed plans for pipeline replacement, including specific stations, valves, fittings, and air release valve locations. The project includes removing existing force mains, installing new pipes via open trench and directional drilling methods, and implementing a complex construction sequencing plan to minimize service interruptions.
The project is funded through Orange County's Capital Improvement Program (CIP Funding Code: 1539-0051) with an estimated cost of $1,248,770. The corresponding state and local contract opportunity requires electronic submission via the OpenGov e-Procurement Platform by 4:00 pm EST on Tuesday, June 14, 2022. The project involves careful coordination with existing utilities, including water, wastewater, gas, electric, and telecommunications infrastructure. Key technical requirements include maintaining continuous service, protecting existing infrastructure, using approved materials and installation methods, and following strict notification and safety protocols during construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOARD OF COUNTY COMMISSIONERS
JERRY L. DEMMINGS
ORANGE COUNTY MAYOR
NICOLE H. WILSON
DISTRICT 1
CHRISTINE MOORE
DISTRICT 2
MAYRA URIBE
DISTRICT 3
MARIBEL GOMEZ CORDERO
DISTRICT 4
EMILY BONILLA
DISTRICT 5
VICTORIA P. SIPLIN
DISTRICT 6
BYRON W. BROOKS, AICP
COUNTY ADMINISTRATOR
ED TORRES, M.S., P.E., LEED AP
DIRECTOR ORANGE COUNTY UTILITIES DEPARTMENT
OCU FILE NO.: 97811
CIP FUNDING CODE:
1539-0051
ATTENTION IS DIRECTED TO THE FACT THAT THESE
PLANS MAY HAVE BEEN REDUCED IN SIZE BY
REPRODUCTION. THIS MUST BE CONSIDERED WHEN
OBTAINING SCALED DATA. DIMENSION
INFORMATION SHOULD NOT BE OBTAINED BY
SCALING THE PLANS.
ORANGE COUNTY UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD
ORLANDO, FLORIDA 32825
(407) 254-9900
LAKE UNDERHILL FORCE MAIN
REPLACEMENT
100% CONSTRUCTION DRAWINGS
AUGUST 2021SEPTEMBER
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
LOCATION MAP
N
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
LOCATES SUNSHINE ONE CALL----------------------------------- 800-432-4770
ELECTRIC DUKE ENERGY-------------------------------------------- 407-398-6670
GAS TECO PEOPLES GAS------------------------------------ 407-420-6609
FIBER OPTIC COMMCAST COMMUNICATIONS--------------------- 407-312-5944
FIBER OPTIC LEVEL 3 COMMUNICATIONS--------------------------- 720-888-2061
PHONE BRIGHT HOUSE NETWORKS-------------------------- 407-532-8509, 407-532-8520
UTILITIES ORANGE COUNTY DISPATCH ------------------------ 407-254-9798 (24-HR ASSISTANCE)
EMERGENCY NUMBERS
PHONE CENTURY LINK--------------------------------------------- 407-815-5344, 407-557-6766 PHONE MCI------------------------------------------------------------- 972-729-6016
PHONE SMART CITY TELECOM---------------------------------- 407-828-6648
PHONE TW TELECOM------------------------------------------------ 407-215-6895
SYMBOL, ABBREVIATIONS AND LEGENDS
GENERAL NOTES
1. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN EXCAVATING IN PROXIMITY
OF INCLUDING, BUT NOT LIMITED TO; WATER MAINS, WASTEWATER FORCE MAINS, GRAVITY
MAINS, RECLAIMED WATER MAINS, ELECTRIC, GAS, CABLE TV, TELECOMMUNICATIONS,
STORM WATER, FIBER OPTIC AND OTHER UNDERGROUND FACILITIES. MAIN LOCATIONS
SHOWN ON PLANS MAY NOT BE EXACT. THE CONTRACTOR IS RESPONSIBLE FOR FIELD
VERIFYING EXISTING UTILITY LOCATIONS.
2. SHOULD A PIPE EMERGENCY OCCUR, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
OCU DISPATCH OPERATOR (407-836-2777) AND THE OCU INSPECTOR.
3. THE CONTRACTOR SHALL NOTIFY THE OCU CONSTRUCTION INSPECTION SECTION, FIELD
SERVICES DIVISION AT LEAST 10 CALENDAR DAYS PRIOR TO COMMENCEMENT OF THE
CONSTRUCTION PROJECT BY CALLING (407) 254-9798.
4. THE CONTRACTOR SHALL NOTIFY THE OCU CONSTRUCTION INSPECTOR IN ACCORDANCE
WITH TABLE 4110-1 "UTILITIES' SCHEDULE OF NOTIFICATIONS IN THIS MANUAL.
5. THE MATERIALS, PRODUCTS, AND CONSTRUCTION OF ALL UTILITIES CONNECTING TO THE
OCU SYSTEM SHALL BE IN CONFORMANCE WITH THE STANDARDS, AND CONSTRUCTION
SPECIFICATIONS, AND APPENDIX D IN THIS MANUAL.
6. ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO; WATER MAINS, FORCE MAINS, RECLAIMED WATER MAIN, SANITARY GRAVITY PIPES, STORM WATER PIPES, ELECTRIC, TELEPHONE, GAS, CABLE TV AND OTHER UTILITY FACILITIES WITHIN THE LIMITS OF THE
PROJECT WILL BE SUPPORTED AND PROTECTED AGAINST DAMAGE DURING CONSTRUCTION.
7. THE CONTRACTOR SHALL ADJUST ALL EXISTING OCU MAINS AND FACILITIES IN CONFLICT
WITH NEW GRADE, NEW OR ALTERED ROADWAYS, SIDEWALKS, DRIVEWAYS, CURBS, OR
STORM WATER IMPROVEMENTS. OCU FACILITIES TO BE ADJUSTED INCLUDE, BUT ARE NOT
LIMITED TO; PIPELINES, PUMP STATIONS, VALVE BOXES, AIR RELEASE VALVES, FIRE
HYDRANTS, MANHOLE COVERS, AND METERS. ALL ADJUSTMENTS SHALL BE MADE TO
CURRENT STANDARDS.
8. ONLY OCU PERSONNEL SHALL OPERATE EXISTING OCU WATER, WASTEWATER, AND
RECLAIMED WATER VALVES. THE CONTRACTOR IS RESPONSIBLE FOR OPERATING ANY
NEWLY INSTALLED VALVE THAT HAS NOT BEEN CLEARED FOR USAGE BY FDEP AND OCU. THE
CONTRACTOR SHALL COORDINATE VALVE OPERATION WITH THE OCU INSPECTOR. FOR
OPERATION OF MAINS NOT OWNED BY OCU, IT IS THE CONTRACTOR'S RESPONSIBILITY TO
COORDINATE WITH THE APPROPRIATE UTILITY REPRESENTATIVE.
9. CONSTRUCTION ACTIVITIES SHALL NOT CAUSE INTERRUPTIONS IN WATER, WASTEWATER, OR
RECLAIMED WATER SERVICE. THE CONTRACTOR SHALL COORDINATE PRE-APPROVED
INTERRUPTIONS OF SERVICE WITH THE OCU INSPECTOR 7 WORKING DAYS IN ADVANCE AND
WRITTEN NOTICE SHALL BE GIVEN TO AFFECTED CUSTOMERS AT LEAST 4 WORKING DAYS IN
ADVANCE.
10.THE CONTRACTOR SHALL PROVIDE FOR BYPASSING AND / OR HAULING OF WASTEWATER
DURING APPROVED INTERRUPTIONS OF WASTEWATER FLOWS AND CONNECTIONS. THE
CONTRACTOR SHALL SUBMIT A BYPASS OR HAUL PLAN, REVIEWED AND APPROVED BY A
PROFESSIONAL ENGINEER TO OCU DEVELOPMENT ENGINEERING AND TO THE INSPECTOR
FOR APPROVAL PRIOR TO IMPLEMENTATION BY CONTRACTOR.
11. ALL VALVES INSTALLED AS PART OF THIS CONSTRUCTION PROJECT SHALL REMAIN CLOSED
DURING CONSTRUCTION. KEEP VALVES ON ALL WET TAPS CLOSED UNTIL CLEARED BY FDEP.
DO NOT CONNECT NEWLY CONSTRUCTED WATER MAINS TO ANY EXISTING WATER MAINS
UNLESS CLEARED BY FDEP AND OCU.
12.THE CONTRACTOR SHALL PROVIDE A JUMPER ASSEMBLY WITH AN APPROVED BACKFLOW
PREVENTER FOR MAKING TEMPORARY CONNECTIONS TO AN EXISTING POTABLE WATER
SOURCE IN ORDER TO CHLORINATE AND FLUSH NEW WATER MAINS WITH POTABLE WATER.
ANY TEMPORARY POTABLE WATER CONNECTIONS TO RECLAIMED WATER OR FORCE MAIN
SHALL ALSO BE EQUIPPED WITH AN APPROVED BACKFLOW PREVENTER.
13.FOR PVC PIPE, NO JOINT DEFLECTION OR PIPE BENDING IS ALLOWED. ALIGNMENT CHANGE
SHALL BE MADE ONLY WITH FITTINGS.
14.FOR DIP PIPE, LONG RADIUS CURVES, EITHER HORIZONTAL OR VERTICAL, MAY BE INSTALLED
WITH STANDARD PIPE BY DEFLECTIONS AT THE JOINTS. MAXIMUM DEFLECTIONS AT PIPE
JOINTS, FITTINGS AND LAYING RADIUS FOR THE VARIOUS PIPE LENGTHS SHALL NOT EXCEED
75 PERCENT OF THE PIPE MANUFACTURER'S RECOMMENDATION.
15.FOR APPROVED PVC OR HDPE PIPE USED IN A HORIZONTAL DIRECTIONAL DRILL
INSTALLATION, THE CURVATURE AND/OR DEFLECTION SHALL NOT EXCEED THE PARAMETERS
ESTABLISHED IN THIS MANUAL.
16. ALL DAMAGE TO ORANGE COUNTY INFRASTRUCTURE, PIPELINES, AND ASSETS SHALL BE
REPAIRED IMMEDIATELY BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE WITH AN
APPROVED METHOD BY THE COUNTY. IF THE REPAIR IS NOT PERFORMED IN A TIMELY
MANNER, AS DETERMINED BY THE ORANGE COUNTY UTILITY INSPECTOR, ORANGE COUNTY
MAY PERFORM REPAIRS AND THE CONTRACTOR WILL BE CHARGED FOR ALL EXPENSES
ASSOCIATED WITH THE REPAIR.
17.THE CONTRACTOR SHALL BE LIABLE FOR ANY AND ALL SANITARY SEWER OVERFLOWS (SSO)
ASSOCIATED WITH THE WORK, REGARDLESS OF FAULT. THE CONTRACTOR WILL BE
ASSESSED PENALTIES FOR ANY AND EACH SSO AS SPECIFIED IN SECTION 3110, GENERAL
CONSTRUCTION REQUIREMENTS.
SURVEY NOTES
SURVEYOR’S REPORT
TOPOGRAPHIC SURVEY
FORCE MAIN REPLACEMENT
LAKE UNDERHILL ROAD
ORANGE COUNTY, FLORIDA
ARTICLE I
DEFINITIONS, GENERALLY:
CLIENT: SHALL MEAN ORLANDO UTILITY COMMISION.
SURVEYOR: SHALL MEAN THE FIRM OF ATKINS NORTH AMERICA, INC., DULY AUTHORIZED TO PRACTICE SURVEYING AND MAPPING BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES UNDER
CERTIFICATE OF AUTHORIZATION NO. LB24.
SURVEY MAP: SHALL MEAN THE GRAPHIC DEPICTION OF THE TOPOGRAPHIC SURVEY IN THE FORM OF THE “TOPOGRAPHIC SURVEY” MAP MADE A PART HEREOF AND INCORPORATED HEREIN BY REFERENCE.
PROJECT AREA: SHALL MEAN THAT AREA INDICATED IN ARTICLE III OF THIS REPORT, REFERENCE TO WHICH IS MADE
FOR A MORE FULL AND COMPLETE DESCRIPTION THEREOF.
ARTICLE II
MAP/REPORT OF TOPOGRAPHIC SURVEY:
SEE SURVEY MAP/REPORT AS INCORPORATED HEREIN AND MADE A PART HEREOF BY REFERENCE. THE DATE OF COMPLETION OF ORIGINAL FIELD SURVEY (THE “SURVEY DATE”) IN CONNECTION WITH SAME WAS ON MARCH 10, 2020.
ARTICLE III
GENERAL DESCRIPTION OF PROJECT AREA:
THAT PORTION OF LAKE UNDERHILL ROAD IN ORANGE COUNTY, FLORIDA, THE SAME AS MORE FULLY SHOWN ON THE
SURVEY MAP ANNEXED HERETO AND MADE A PART HEREOF.
ARTICLE IV
ACCURACY:
THE EXPECTED USE OF THE LAND, AS CLASSIFIED IN THE “STANDARDS OF PRACTICE FOR LAND SURVEYING IN THE STATE OF FLORIDA,” PURSUANT TO RULE 5J-17 OF THE FLORIDA ADMINISTRATIVE CODE IS “COMMERCIAL/HIGH RISK.”
THE MINIMUM RELATIVE DISTANCE ACCURACY FOR THIS TYPE OF SURVEY IS 1 FOOT IN 10,000 FEET. ALTHOUGH A BOUNDARY SURVEY WAS NOT PERFORMED, THE ACCURACY OBTAINED BY MEASUREMENT AND CALCULATION OF A CLOSED GEOMETRIC FIGURE WAS FOUND TO EXCEED THIS REQUIREMENT. FOR MORE INFORMATION REGARDING METHODS AND PROCEDURES FOR THIS SURVEY, REFER TO THE BOUNDARY INCONSISTENCIES PORTION (ARTICLE VII)
OF THIS REPORT.
ARTICLE V
SOURCES OF DATA:
1. BEARINGS AS SHOWN HEREON REFER TO A CALCULATED BEARING OF N 89°58’48” E ALONG THE CENTERLINE OF
LAKE UNDERHILL ROAD.
2. ALL FEATURES AND BEARINGS ARE BASED ON THE STATE PLANE COORDINATE SYSTEM FOR THE EAST ZONE OF
FLORIDA, NORTH AMERICAN DATUM OF 1983/2011 ADJUSTMENT (NAD83/11).
3. ELEVATIONS AS DEPICTED ON THE SURVEY MAP ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF
1988 (NAVD88).
4. ORANGE COUNTY BENCHMARK NUMBER C1309032, ELEVATION +88.83 FEET WAS USED FOR VERTICAL CONTROL.
THE BENCHMARK IS A 3 1/2" ALUMINUM ORANGE COUNTY CONTROL DISC SET IN A CONCRETE PAD FOR LARGE WATER VALVES, 115 FEET, MORE OR OR LESS WEST OF THE CENTERLINE OF CHICKASAW TRAIL AND 35 FEET, MORE OR LESS, SOUTH OF THE CENTERLINE OF THE ENTRANCE TO FLORIDA HOSPITAL (EAST.
5. ORANGE COUNTY BENCHMARK NUMBER C1309028, ELEVATION +82.578 FEET WAS USED FOR VERTICAL CONTROL. THE BENCHMARK IS A 3 1/2" ALUMINUM ORANGE COUNTY CONTROL DISC SET IN NORTH END OF THE DROP INLET ON THE EAST SIDE CHICKASAW TRAIL AND IS LOCATED 900 FEET SOUTH, MORE OR LESS FROM THE CENTERLINE OF OF LAKE UNDERHILL ROAD AND 45 FEET, MORE OR LESS EAST FROM THE CENTERLINE OF CHICKASAW TRAIL.
6. TAX FOLIO DATA PUBLISHED BY THE ORANGE COUNTY PROPERTY APPRAISER’S OFFICE FOR THE 2019 TAX YEAR
(FOR REFERENCE ONLY).
7. SUBSURFACE UTILITIES INDICATED ON THE SURVEY MAP WERE LOCATED BASED ON SURFACE MARKS PLACED
BY OTHERS.
8. SUNSHINE STATE ONE-CALL OF FLORIDA WAS CONTRACTED ON FEBRUARY 7, 2020 AND DESIGN TICKET NUMBER 038001215 WAS ISSUED FOR NON-EXCAVATION PURPOSES ONLY. THIS TICKET NUMBER SHOULD BE REFERRED TO BY CONTRACTORS WHEN CALLING FOR PRE-CONSTRUCTION EXCAVATION TICKETS. THE FOLLOWING COMPANIES
PROVIDE SERVICES WITHIN THE PROJECT AREA:
AMERICAN TRAFFIC SOLUTIONS
CHARTER COMMUNICATIONS
BLACK & VEATCH, ORLANDO
CENTURYLINK
DUKE ENERGY
COMCAST COMMUNICATIONS
MCI
ARTICLE VI
LIMITATIONS:
1. SINCE NO OTHER INFORMATION OTHER THAN WHAT IS CITED IN THE SOURCES OF DATA WERE FURNISHED, THE CLIENT IS HEREBY ADVISED THAT THERE MAY LEGAL RESTRICTIONS ON THE PROJECT AREA THAT ARE NOT SHOWN ON THE SURVEY MAP OR CONTAINED WITHIN THIS REPORT THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ORANGE COUNTY, OR ANY OTHER PUBLIC AND PRIVATE ENTITIES AS THEIR JURISDICTIONS MAY APPEAR. THE SURVEYOR MAKES NO REPRESENTATION AS TO OWNERSHIP OR POSSESSION OF THE PROJECT AREA BY ANY ENTITY OR
INDIVIDUAL WHO MAY APPEAR OF PUBLIC RECORD.
2. NO EXCAVATION OR DETERMINATION WAS MADE AS TO HOW THE PROJECT AREA IS SERVED BY UTILITIES.
SUBSURFACE UTILITIES, INCLUDING, BUT WITHOUT LIMITATION TO PIPES, WIRES, VAULTS, BOXES, DRAIN TILES, VOIDS, CABLES AND OTHER MATERIALS ANCILLARY TO THE DELIVERY AND/OR DISPOSAL OF WATER, WASTEWATER, SEWAGE, ELECTRICITY, GAS, TELEPHONE SERVICE, CABLE TELEVISION &C. AS THEY MAY EXIST WITHIN, UPON, ACROSS OR ABUTTING THE PROJECT AREA WERE NOT LOCATED AND ARE NOT SHOWN. IN ADDITION, THE FOUNDATIONS OF THE EXISTING SURFACE STRUCTURES AS THEY MAY EXIST WITHIN, UPON, ACROSS OR ABUTTING THE PROJECT AREA WERE NOT LOCATED. THIS NOTICE IS REQUIRED BY THE “STANDARDS OF PRACTICE FOR LAND SURVEYING IN THE
STATE OF FLORIDA,” PURSUANT TO RULE 5J-17 OF THE FLORIDA ADMINISTRATIVE CODE.
3. SUBSURFACE SOIL CONDITIONS WERE NOT DETERMINED, AS THIS FALLS OUTSIDE THE PURVIEW OF THIS SURVEY. THESE CONDITIONS MAY INCLUDE THE DETERMINATION OF WETLANDS, FILLED-IN AREAS, GEOLOGICAL/ARCHEOLOGICAL CONDITIONS OR POSSIBLE CONTAMINATION BY HAZARDOUS LIQUID OR SOLID WASTE
THAT MAY OCCUR WITHIN, UPON, ACROSS, ABUTTING OR ADJACENT TO THE PROJECT AREA.
4. WELL-IDENTIFIED FEATURES AS DEPICTED ON THE SURVEY MAP WERE MEASURED TO AN ESTIMATED
HORIZONTAL POSITIONAL ACCURACY OF 1/10 FOOT.
5. THE ELEVATIONS OF WELL-IDENTIFIED FEATURES AS DEPICTED ON THE SURVEY MAP WERE MEASURED TO AN ESTIMATED VERTICAL POSITIONAL ACCURACY OF 1/10 FOOT FOR NATURAL GROUND SURFACES AND 1/100 FOOT FOR
HARDSCAPE SURFACES.
6. NOTICE IS HEREBY GIVEN THAT SUNSHINE STATE ONE CALL OF FLORIDA, INC. MUST BE CONTACTED AT 1-800-432-4770 AT LEAST 2 BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION, EXCAVATION OR DEMOLITION ACTIVITY WITHIN, UPON, ABUTTING OR ADJACENT TO THE PROJECT AREA. THIS NOTICE IS GIVEN IN COMPLIANCE WITH THE “UNDERGROUND FACILITY DAMAGE PREVENTION AND SAFETY ACT,” PURSUANT TO CHAPTER 556.101-111 OF
THE FLORIDA STATUTES.
7. THE SURVEY MAP IS INTENDED TO BE DISPLAYED AT A SCALE OF 1 INCH = 30 FEET IN ENGLISH UNITS OF MEASUREMENT. ATTENTION IS DRAWN TO THE FACT THAT SAID SCALE MAY BE ALTERED BY REPRODUCTION. THIS
MUST BE CONSIDERED WHEN OBTAINING SCALED DATA.
8. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS
PROHIBITED
WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES
9. THIS PRODUCT DOES NOT REPRESENT A BOUNDARY SURVEY OF THE PROJECT AREA. ALL UNDERLYING RIGHT OF WAY, TRACT AND OTHER BOUNDARIES AS DEPICTED ON THE SURVEY MAP WERE ACQUIRED FROM DOCUMENTS OF
PUBLIC RECORD AND ARE INDICATED FOR INFORMATIONAL PURPOSES ONLY.
ARTICLE VII
BOUNDARY INCONSISTENCIES:
1. ALTHOUGH THIS PRODUCT DOES NOT REPRESENT A BOUNDARY SURVEY, CLOSED GEOMETRIC FIGURES WERE MEASURED IN THE FIELD AND MATHEMATICALLY VERIFIED IN A MANNER CONSISTENT WITH SURVEYS FOR COMMERCIAL/HIGH RISK URBAN AREAS. COMPARISONS BETWEEN PLAT, MEASURED AND CALCULATED VALUES, WHEN
THEY APPLY, ARE AS NOTED ON THE SURVEY MAP.
2. THE EXISTENT REALIGNED THEO. DICKINSON DRIVE AS SHOWN IS NOT A DEDICATED RIGHT OF WAY OR
EASEMENT.
ARTICLE VIII
APPARENT PHYSICAL USE:
1. THE PROJECT AREA AND THE SURROUNDING AREA CONSISTS OF PUBLIC HIGHWAY FACILITIES AS MORE FULLY
SHOWN ON THE SURVEY MAP.
2. THESE MEASUREMENTS AND EXAMINATIONS WERE PERFORMED UNDER MY DIRECT SUPERVISION AND IN MY PROFESSIONAL JUDGEMENT, EVERY ATTEMPT WAS MADE TO LOCATE THE DATA IN QUESTION USING THE STANDARD OF CARE FOR SURVEYING AND MAPPING IN THESE MATTERS, SUBJECT TO THE LIMITATIONS AS SET FORTH IN THIS
SURVEY MAP AND REPORT.
ARTICLE IX
EASEMENTS AND ENCUMBRANCES:
NO INFORMATION WAS PROVIDED AS TO THE EXISTENCE OF ANY EASEMENTS OTHER THAT WHAT MAY APPEAR ON THE UNDERLYING MAP OF RECORD OR PREVIOUSLY DISCLOSED TO THE SURVEYOR. PLEASE REFER TO THE LIMITATIONS PORTION (ARTICLE VI) OF THIS REPORT WITH RESPECT TO POSSIBLE RESTRICTIONS OF RECORD AND
UTILITY SERVICES.
ARTICLE X
CLIENT INFORMATION :
THIS “TOPOGRAPHIC SURVEY” AND THE SURVEY MAP AND REPORT RESULTING THEREFROM WERE PREPARED AT THE
INSISTENCE OF AND ARE CERTIFIED TO: ORLANDO UTILITY COMMISSION.
ARTICLE XI
SURVEYOR’S CERTIFICATE :
THE STATE OF FLORIDA )
) S.S.
COUNTY OF ORANGE )
I HEREBY CERTIFY: THAT THIS “TOPOGRAPHIC SURVEY” AND THE SURVEY MAP AND REPORT RESULTING THEREFROM WAS PERFORMED UNDER MY DIRECTION AND IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF AND FURTHER, THAT SAID “TOPOGRAPHIC SURVEY” MEETS THE INTENT OF THE “STANDARDS OF PRACTICE FOR LAND SURVEYING IN THE STATE OF FLORIDA”, PURSUANT TO RULE 5J-17 OF THE FLORIDA ADMINISTRATIVE CODE AND ITS
IMPLEMENTING RULE, CHAPTER 472.027 OF THE FLORIDA STATUTES.
ATKINS NORTH AMERICA, INC.
FLORIDA CERTIFICATE OF AUTHORIZATION NUMBER LB24
BY: _____________________________________________
ALVIN SANTIAGO, PSM
PROFESSIONAL SURVEYOR AND MAPPER NO. 7160
STATE OF FLORIDA
DATE OF FIELD SURVEY: MARCH 10, 2020
DATE OF CERTIFICATION: MARCH 17, 2020
NOTICE: NOT VALID WITHOUT THE SIGNATURE AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER.
ADDITIONS OR DELETIONS TO SURVEY MAPS AND REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES ARE PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. THIS DOCUMENT CONSISTS OF MULTIPLE EXHIBITS AND EACH PART THEREOF SHALL NOT BE CONSIDERED FULL, VALID AND COMPLETE UNLESS ACCOMPANIED BY THE OTHERS. THIS NOTICE IS REQUIRED BY RULE 5J-17 OF THE FLORIDA ADMINISTRATIVE CODE.
© 2001-ATKINS NORTH AMERICA, INC.
AN SNC LAVALIN COMPANY
AS SUCCESSOR IN NAME TO PBS&J
ALL RIGHTS RESERVED
U.S. COPYRIGHT REGISTRATION NO. TXU1-004-364
ORANGE COUNTY UTILITIES, WATER AND SEWER
ORANGE COUNTY PUBLIC WORKS, TRAFFIC
CENTRAL FLORIDA EXPRESSWAY AUTHORITY
SUMMIT BROADBAND
AT&T
UNITI FIBER, LLC
EMBARK COMMUNICATION, INC.
SPRINT
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
C-100
1" = 20'
97811
CS
AR
DT
X
LAKE UNDERHILL FORCE MAIN
REPLACEMENT
KEY SHEET
X
X
PLAN AND PROFILE
C-101
PLAN AND PROFILE
C-102
PLAN AND PROFILE
C-103
PLAN AND PROFILE
C-104
N
ADVENT HEALTH EAST
ORLANDO ER
ER AND
HOSPITAL
MAIN
ENTRANCE
7-ELEVEN
WALMART NEIGHBORHOOD
MARKET
E l e v a t i o n
Profile View of 16-Inch FM
+50
+50
+50
+50
45 45
357 LF PROPOSED 16" C-905 PVC FM
16" CUT-IN SLEEVE
STA: 41+68.39
OFF: 0.02
N: 1528888.616
E: 566353.790
S
S
S
S
S
S S S S S S S S S
S S
S S
S S
S S S S S S
S S
S S
S S S S S S S S S
BT
BT
BT
BT
BT
BT BT
BT BT
BT
BT BT BT BT
BT
B T
BT
BT
BT
BT
BT
BT BT
BT
B T
BT BT BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
B
T
B
T
BT BT BT BT
BT BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
B T
B T
BT
BT
BT
B T
BT
BT
BT
BT
B T
B
T
B
T
S
S
S
BE
BE
BE
BE
BE
BE
BE
BE BE
B E
B E
BE
B E
B
E
B
E
B E
B E
N 89°58'48" E
16" CUT-IN SLEEVE WITH RJ
STA: 41+68.39
OFF: 0.02
N: 1528888.616
E: 566353.790
357 LF PROPOSED 16" C-905 PVC FM
16" X 14" REDUCER
STA: 41+70.15
OFF: 20.16
N: 1528868.482
E: 566355.635
16" PLUG VALVE
STA: 41+71.64
OFF: 20.26
N: 1528868.392
E: 566357.129
16" X 14" BYPASS TAPPING
SLEEVE AND VALVE
STA: 41+65.76
OFF: 20.12
N: 1528868.511
E: 566351.246
16" 45.00 ELBOW
STA: 41+73.93
OFF: 20.25
N: 1528868.415
E: 566359.416
20 LF PROPOSED 16" C-905 PVC FM
16" 45.00 ELBOW
STA: 41+88.98
OFF: 5.03
N: 1528883.700
E: 566374.401
FM
-1
FM
-2
FM
-3
PV-1
FM
-4
FM
-5
00 20' 40'
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
C-101
1" = 20'
97811
CS
AR
DT
X
LAKE UNDERHILL FORCE MAIN
REPLACEMENT
LAKE UNDERHILL ROAD PLAN AND PROFILE
X
X
SCALE: 1" = 20'
PROVIDE STEEL PLATES TO PROVIDE
ACCESS TO DRIVEWAY. THE
DRIVEWAY MUST BE ACCESSIBLE AT
ALL TIMES. CONTRACTOR TO
PROVIDE SIGNAGE TO INDICATE
UNEVEN PAVEMENT TO DRIVERS.
NOTES:
1. EXISTING FORCE MAIN SHALL BE REMOVED WHERE NEW PIPE IS
INSTALLED VIA OPEN TRENCH AND SHALL BE DISPOSED OF MEETING ALL
LOCAL ENVIRONMENTAL REQUIREMENTS.
2. TEMPORARY 16" PVC ABOVEGROUND BYPASS PIPING TO BE LAID OUT
WITHIN THE 10' SEWER LINE EASEMENT.
3. 16" BYPASS TAPPING SLEEVE AND VALVE PROVIDED FOR USE IN BYPASS
PIPING. CONTRACTOR TO CLOSE AND CAP THE PLUG VALVE ONCE
BYPASS OPERATION IS COMPLETED. THE TAPPING VALVE WILL REMAIN
OPEN.
4. THE ESTIMATED SOD REPLACEMENT ON C-101 IS APPROXIMATELY 590
SY.
SUGGESTED CONSTRUCTION SEQUENCING
1. CONSTRUCT THE PROPOSED 16” FM FROM THE PLUG VALVE AT
STA. 48+62 TO THE PLUG VALVE AT STA. 53+52.
2. CONSTRUCT THE PROPOSED 12” FM FROM THE TAPPING SLEEVE AT
STA. 500+95 TO THE TEE AT STA. 53+34.
3. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE TAPPING
VALVE AT STA. 41+66 AND CONNECT TO THE TEE AT STATION 48+64.
4. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE BYPASS
TAPPING SLEEVE AT STA. 53+49 AND CONNECT TO THE TEE AT STA.
53+49.
5. AFTER THE NEWLY CONSTRUCTED 16” AND 12” PIPE IS TESTED AND
READY TO BE PLACED IN SERVICE, CLOSE THE EXISTING VALVE AT 41+67
AND INSTALL THE LINE STOP ON EXISTING FM AT STA. 53+46. TAP
EXISTING FM AT STA. 41+67 AND STA. 53+49 AND CLOSE THE EXISTING
VALVE JUST SOUTH OF THE TAPPING SLEEVE AT STA. 500+95.
6. CONSTRUCT REMAINING PROPOSED 16” FM.
7. AFTER ALL PROPOSED PIPING IS TESTED AND READY TO BE PLACED IN
SERVICE:
a. INSTALL THE LINE STOP ON EXISTING FM AT 55+76 AND TAP
EXISTING FM AT STA 55+77
b. OPEN THE EXISTING VALVE AT STA.41+67 AND CLOSE THE PLUG
VALVE AT STA. 41+72
c. OPEN THE PLUG VALVE AT STA. 48+62 AND CLOSE THE PLUG VALVE
AT STA 48+63
d. OPEN THE PLUG VALVE AT STA. 53+51 AND CLOSE THE PLUG VALVE
AT STA. 53+48.
REMOVE 357 LF EXISTING 16" FM
EXISTING GROUND
125 SY ROADWAY CUT
EXISTING 16" FM
REMOVE AND
REPLACE TREE
TEMPORARY BYPASS
PIPING CONNECTION
PROVIDE PROTECTION
FOR TREE
177 S.Y. ROADWAY CUT
35 LF CURB & GUTTER REPLACEMENT
35 LF CURB & GUTTER REPLACEMENT
100 LF CURB & GUTTER REPLACEMENT
97811-SAMPLE 01
97811-SAMPLE 02
ER MAIN
ENTRANCE
D-102 e v a t i o n
Profile View of 16-Inch FM
+50
+50
+50
+50
+50
C-101
370 LF PROPOSED 16" C-905 PVC FM
16" X 8" TEE
STA: 48+38.54
OFF: 0.16
N: 1528891.254
E: 567023.703
16" X 8" TEE
STA: 48+64.41
OFF: 0.16
N: 1528888.486
E: 567048.299
16" X 8" TEE
STA: 48+93.21
OFF: 0.07
N: 1528886.469
E: 567076.384
16" PLUG VALVE
STA: 48+61.56
OFF: 0.13
N: 1528890.430
E: 567046.225
16" PLUG VALVE
STA: 48+98.13
OFF: 0.01
N: 1528886.539
E: 567081.310
63 LF PROPOSED 16" HDPE DR 11 FM
AIR RELEASE VALVE
STA: 48+87.14
OFF: 0.05
N: 1528886.478
E: 567070.311
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
O
E
S S
S
S
S
S S
S S S
S S
S S S
S S
S S S
S S S S S S S
S
S S
S S
S S
S S S S
S
S
S
BT
BT
BT
BT
BT BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT BT BT BT BT BT BT
BT
BT
BT
BT
BT
B T
B T
BT
BT
BT
BT
BT
BT
BT BT
BT BT
BT BT BT
BT
BT
BT
BT
BT
BT
BT BT BT BT
BT
BT
BT
BT
BT
BT
BT
BT BT
BT
BT
BT BT
BT BT
BT
BT
BT
BT
BT
BT
BT
BT
BT BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
G
G
BE
BE
B T
S
S
S
S
G G G G G G G G G G G G G G G G G G G G G G G G G
G
G G G G
G G
G G
N 89°58'48" E
370 LF PROPOSED 16" C-905 PVC FM
16" X 8" TEE
STA: 48+38.54
OFF: 0.16
N: 1528891.254
E: 567023.703
4" PLUG VALVE
STA: 48+38.57
OFF: -3.31
N: 1528894.728
E: 567023.711
8" X 4" REDUCER
STA: 48+38.55
OFF: -1.88
N: 1528893.293
E: 567023.699
4" PLUG VALVE
STA: 48+93.34
OFF: -7.91
N: 1528894.447
E: 567076.495
8" X 4" REDUCER
STA: 48+93.35
OFF: -6.53
N: 1528893.062
E: 567076.508
63 LF PROPOSED 16" HDPE DR 11 FM
16" X 8" TEE
STA: 48+93.21
OFF: 0.07
N: 1528886.469
E: 567076.384
16" 45 ELBOW
STA: 48+67.38
OFF: 0.11
N: 1528886.507
E: 567050.522
16" 45 ELBOW
STA: 48+60.17
OFF: 0.05
N: 1528891.439
E: 567045.257
16" X 16" TEE
STA: 48+64.41
OFF: 0.16
N: 1528888.486
E: 567048.299
AIR RELEASE VALVE
STA: 48+87.14
OFF: 0.05
N: 1528886.478
E: 567070.311
16" PLUG VALVE
STA: 48+61.56
OFF: 0.13
N: 1528890.430
E: 567046.225
16" PLUG VALVE
STA: 48+64.45
OFF: 2.94
N: 1528886.412
E: 567046.450
16" PLUG VALVE
STA: 48+98.13
OFF: 0.01
N: 1528886.539
E: 567081.310
16" 11.25 ELBOW
(VERTICAL BEND)
STA: 49+01.37
OFF: 0.08
N: 1528886.472
E: 567084.543
16" TRANSITION FITTING
WITH RJ
STA: 49+03.10
OFF: 0.08
N: 1528886.472
E: 567086.271
FM
-6
FM
-7
FM
-8
PV-3
PV-4
FM
-9
FM
-1
PV-2
PV-5
FM
-1
FM
-1
FM
-1
FM
-1
PV-6
ARV-1
00 20' 40'
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
C-102
1" = 20'
97811
CS
AR
DT
X
LAKE UNDERHILL FORCE MAIN
REPLACEMENT
LAKE UNDERHILL ROAD PLAN AND PROFILE
X
X
SCALE: 1" = 20'
50' X 10' HDD RIG
AND SETUP AREA
COORDINATE CONNECTION
TO EXISTING PRIVATE FM
COORDINATE CONNECTION
TO EXISTING PRIVATE FM
NOTES
1. EXISTING FORCE MAIN SHALL BE REMOVED WHERE NEW PIPE IS
INSTALLED VIA OPEN TRENCH AND SHALL BE DISPOSED OF
MEETING ALL LOCAL ENVIRONMENTAL REQUIREMENTS.
2. EXISTING FORCE MAIN SHALL BE GROUT-FILLED WHERE NEW PIPE
IS INSTALLED VIA DIRECTIONAL DRILL AS SHOWN IN PLANS.
GROUT-FILLED PIPE SHALL BE CUT, CAPPED, AND PLACED OUT OF
SERVICE.
3. TEMPORARY 16" PVC ABOVEGROUND BYPASS PIPING TO BE LAID
OUT WITHIN THE 10' SEWER LINE EASEMENT.
4. 16" BYPASS TAPPING SLEEVE AND VALVE PROVIDED FOR USE IN
BYPASS PIPING. CONTRACTOR TO CLOSE AND CAP THE PLUG
VALVE. THE TAPPING VALE WILL REMAIN OPEN.
5. THE CONTRACTOR SHALL PROVIDE BYPASS CONNECTIONS FOR THE
TWO EXISTING PRIVATE PUMP STATIONS. THE PEAK FLOW OF
EACH OF THE PUMP STATIONS IS APPROXIMATELY 200 GPM AND
150 GPM.
6. THE ESTIMATED SOD REPLACEMENT ON C-102 IS APPROXIMATELY
410 SY.
EXISTING FORCE MAIN TO BE CAPPED AND GROUT FILLED
SUGGESTED CONSTRUCTION SEQUENCING
1. CONSTRUCT THE PROPOSED 16” FM FROM THE PLUG VALVE AT
STA. 48+62 TO THE PLUG VALVE AT STA. 53+52.
2. CONSTRUCT THE PROPOSED 12” FM FROM THE TAPPING SLEEVE
AT STA. 500+95 TO THE TEE AT STA. 53+34.
3. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE
TAPPING VALVE AT STA. 41+66 AND CONNECT TO THE TEE AT
STATION 48+64.
4. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE
BYPASS TAPPING SLEEVE AT STA. 53+49 AND CONNECT TO THE TEE
AT STA. 53+49.
5. AFTER THE NEWLY CONSTRUCTED 16” AND 12” PIPE IS TESTED
AND READY TO BE PLACED IN SERVICE, CLOSE THE EXISTING VALVE
AT 41+67 AND INSTALL THE LINE STOP ON EXISTING FM AT STA.
53+46. TAP EXISTING FM AT STA. 41+67 AND STA. 53+49 AND
CLOSE THE EXISTING VALVE JUST SOUTH OF THE TAPPING SLEEVE
AT STA. 500+95.
6. CONSTRUCT REMAINING PROPOSED 16” FM.
7. AFTER ALL PROPOSED PIPING IS TESTED AND READY TO BE PLACED
IN SERVICE:
a. INSTALL THE LINE STOP ON EXISTING FM AT 55+76 AND TAP
EXISTING FM AT STA 55+77
b. OPEN THE EXISTING VALVE AT STA.41+67 AND CLOSE THE
PLUG VALVE AT STA. 41+72
c. OPEN THE PLUG VALVE AT STA. 48+62 AND CLOSE THE PLUG
VALVE AT STA 48+63
d. OPEN THE PLUG VALVE AT STA. 53+51 AND CLOSE THE PLUG
VALVE AT STA. 53+48.
REMOVE 380 LF EXISTING 16" FM
EXISTING GROUND
GROUT-FILL 60 LF EXISTING 16" FM
97811-SAMPLE 02
3' MIN.
SEPARATION
e v a t i o n
Profile View of 16-Inch FM
49 50
+50
+50
+50
+50
90 LF PROPOSED 16" C-905 PVC FM
AIR RELEASE VALVE
STA: 53+26.89
OFF: -0.17
N: 1528887.400
E: 567509.682
351 LF PROPOSED 16" HDPE DR 11 FM
16" PLUG VALVE
STA: 53+23.86
OFF: -0.07
N: 1528887.340
E: 567506.649
BURIED ELECTRIC
18" RCP
16" WM
BURIED TELEPHONE
BURIED GAS
16" SANITARY FM
(TO BE REMOVED)
BURIED FIBER OPTIC
BURIED FIBER OPTIC
BURIED ELECTRIC
16" X 16" TEE
STA: 53+49.36
OFF: -0.02
N: 1528887.697
E: 567532.151
16" PLUG VALVE
STA: 53+52.03
OFF: -0.02
N: 1528887.760
E: 567534.817
16" X 12" TEE
STA: 53+33.90
OFF: 0.08
N: 1528887.248
E: 567516.688
OE
OE
OE
OE
OE
OE OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
O
E
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
O
E
S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
B
T
B
T
BT
BT
BT
BT
B
T
BT
BT
BT
BT
BT
BT
BT
BT
BT
G
G
G
G
G
B E
B
E
B
E
B
E
B
E
B
E
B
E
B E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
BE
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
G G G G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G G
G G
G G G
G
G
G
G
B E
B E
B E
B E
B E
BE
BE
B E
B E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
B
F
O
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
B
T
B
T
B
T
B
T
B T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B T
B T
BT BT BT BT
BT
B T
B T
B T
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B F
O
BFO
BFO
B
F
O
S
S
S
S
S
S
S
S
S
S
S
S
S
S S
S S
S S
S
S
S
S
S
S
S
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
F
O
B
E
B
E
B
E
B
E
B
E
B
E
B
E
B
E
W
W
W
W
W
W
W
W
W
W
W
351 LF PROPOSED 16" HDPE DR 11 FM
16" X 12" TEE
STA: 53+33.91
OFF: -0.01
N: 1528887.337
E: 567516.702
AIR RELEASE VALVE
STA: 53+26.89
OFF: -0.17
N: 1528887.400
E: 567509.682
16" PLUG VALVE
STA: 53+23.86
OFF: -0.07
N: 1528887.340
E: 567506.649
90 LF PROPOSED 16" C-905 PVC FM
16" CAP
STA: 52+27.88
OFF: 3.96
N: 1528884.568
E: 567410.633
16" LINE STOP
STA: 53+46.25
OFF: 4.81
N: 1528882.794
E: 567529.147
16"X16" BYPASS TAPPING
SLEEVE AND VALVE
STA: 53+48.94
OFF: 4.95
N: 1528882.718
E: 567531.842
16" PLUG VALVE
STA: 53+49.10
OFF: 1.58
N: 1528886.084
E: 567531.925
16" 11.25 ELBOW
STA: 53+22.15
OFF: -0.14
N: 1528887.428
E: 567504.950
12" 45.00 ELBOW
STA: 502+98.89
OFF: -0.01
N: 1528893.092
E: 567515.282
16" TRANSITION FITTING
WITH RJ
STA: 53+20.68
OFF: 0.00
N: 1528887.316
E: 567503.473
12" 45.00 ELBOW
STA: 503+00.83
OFF: -0.01
N: 1528891.783
E: 567516.729
12" 45.00 ELBOW
STA: 501+06.10
OFF: 0.00
N: 1528964.214
E: 567348.785
12" 45.00 ELBOW
STA: 501+08.93
OFF: 0.00
N: 1528964.236
E: 567351.576
12" TAPPING
SLEEVE AND VALVE
STA: 500+95.04
OFF: 0.01
N: 1528956.226
E: 567341.147
12" PLUG VALVE
STA: 500+98.79
OFF: 0.00
N: 1528958.944
E: 567343.733
12" 22.50 ELBOW
STA: 501+80.77
OFF: 0.00
N: 1528912.993
E: 567401.929
12" 22.50 ELBOW
STA: 502+25.23
OFF: 0.00
N: 1528892.961
E: 567441.623
12" PLUG VALVE
STA: 503+03.02
OFF: 0.00
N: 1528889.590
E: 567516.726
16" X 16" TEE
STA: 53+49.36
OFF: -0.02
N: 1528887.697
E: 567532.151
16" PLUG VALVE
STA: 53+52.03
OFF: -0.02
N: 1528887.760
E: 567534.817
202 LF PROPOSED 12" C-905 PVC FM
63 LF PROPOSED 16" HDPE DR 11 FM
PV-7
FM
-1
FM
-1
FM
-1
FM
-2
FM
-1
FM
-1
PV-8
FM
-2
FM
-2
FM
-2
FM
-2
FM
-2
ARV-2
FM
-2
PV-1
PV-1
FM
-2
PV-9
FM
-2
12" LINE STOP
STA: 51+58.70
OFF: -65.26
N: 1528954.698
E: 567342.366
FM
-3
E l e v a t i o n
Profile View of 12-Inch FM
+50
+50
+50
503 503
44 LF PROPOSED 12" C-905 PVC FM
12" TAPPING SLEEVE
STA: 51+57.40
OFF: -66.73
N: 1528956.182
E: 567341.083
12" 45.00 ELBOW
STA: 51+67.79
OFF: -74.94
N: 1528964.252
E: 567351.585
12" 22.50 ELBOW
STA: 52+18.78
OFF: -24.32
N: 1528912.970
E: 567401.903
12" 22.50 ELBOW
STA: 52+58.73
OFF: -4.77
N: 1528892.896
E: 567441.591
12" PLUG VALVE
STA: 53+33.96
OFF: -2.21
N: 1528889.531
E: 567516.705
12" 45.00 ELBOW
STA: 51+65.04
OFF: -74.85
N: 1528964.204
E: 567348.835
BURIED FIBER OPTIC
BURIED FIBER OPTIC
BURIED FIBER OPTIC
12" 45.00 ELBOW
STA: 503+00.83
OFF: -0.01
N: 1528891.783
E: 567516.729
12" 45.00 ELBOW
STA: 502+98.89
OFF: -0.01
N: 1528893.092
E: 567515.282
12" PLUG VALVE
STA: 51+59.99
OFF: -69.44
N: 1528958.856
E: 567343.711
00 20' 40'
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
C-103
1" = 20'
97811
CS
AR
DT
X
LAKE UNDERHILL FORCE MAIN
REPLACEMENT
LAKE UNDERHILL ROAD PLAN AND PROFILE
X
X
SCALE: 1" = 20'
NOTES:
1. EXISTING FORCE MAIN SHALL BE REMOVED WHERE NEW PIPE IS INSTALLED VIA
OPEN TRENCH AND SHALL BE DISPOSED OF MEETING ALL LOCAL
ENVIRONMENTAL REQUIREMENTS.
2. EXISTING FORCE MAIN SHALL BE GROUT-FILLED WHERE NEW PIPE IS INSTALLED
VIA DIRECTIONAL DRILL AS SHOWN IN PLANS. GROUT-FILLED PIPE SHALL BE
CUT, CAPPED, AND PLACED OUT OF SERVICE.
3. TEMPORARY 16" PVC ABOVEGROUND BYPASS PIPING TO BE LAID OUT WITHIN
THE 10' SEWER LINE EASEMENT.
4. 16" BYPASS TAPPING SLEEVE AND VALVE PROVIDED FOR USE IN BYPASS PIPING.
CONTRACTOR TO CLOSE AND CAP THE PLUG VALVE. THE TAPPING VALE WILL
REMAIN OPEN.
5. 12"X12" TEE SHALL BE USED AS A CONNECTION POINT FOR TEMPORARY BYPASS
PIPING. THE TEE SHALL BE CAPPED AFTER BYPASS PIPING IS REMOVED.
4. THE ESTIMATED SOD REPLACEMENT ON C-103 IS APPROXIMATELY 360 SY.
5. THE ESTIMATED SIDEWALK REPLACEMENT ON C-103 IS APPROXIMATELY 130 SY.
EXISTING FORCE MAIN TO BE CAPPED AND GROUT FILLED
SUGGESTED CONSTRUCTION SEQUENCING
1. CONSTRUCT THE PROPOSED 16” FM FROM THE PLUG VALVE AT STA. 48+62 TO
THE PLUG VALVE AT STA. 53+52.
2. CONSTRUCT THE PROPOSED 12” FM FROM THE TAPPING SLEEVE AT
STA. 500+95 TO THE TEE AT STA. 53+34.
3. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE TAPPING VALVE
AT STA. 41+66 AND CONNECT TO THE TEE AT STATION 48+64.
4. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE BYPASS TAPPING
SLEEVE AT STA. 53+49 AND CONNECT TO THE TEE AT STA. 53+49.
5. AFTER THE NEWLY CONSTRUCTED 16” AND 12” PIPE IS TESTED AND READY TO
BE PLACED IN SERVICE, CLOSE THE EXISTING VALVE AT 41+67 AND INSTALL THE
LINE STOP ON EXISTING FM AT STA. 53+46. TAP EXISTING FM AT STA. 41+67
AND STA. 53+49 AND CLOSE THE EXISTING VALVE JUST SOUTH OF THE TAPPING
SLEEVE AT STA. 500+95.
6. CONSTRUCT REMAINING PROPOSED 16” FM.
7. AFTER ALL PROPOSED PIPING IS TESTED AND READY TO BE PLACED IN SERVICE:
a. INSTALL THE LINE STOP ON EXISTING FM AT 55+76 AND TAP EXISTING FM
AT STA 55+77
b. OPEN THE EXISTING VALVE AT STA.41+67 AND CLOSE THE PLUG VALVE AT
STA. 41+72
c. OPEN THE PLUG VALVE AT STA. 48+62 AND CLOSE THE PLUG VALVE AT STA 48+63
d. OPEN THE PLUG VALVE AT STA. 53+51 AND CLOSE THE PLUG VALVE AT STA.
53+48.
REMOVE 186 LF EXISTING 16" FM
EXISTING GROUND
GROUT-FILL 256 LF OF EXISTING 16" FM
REMOVE 101 LF OF EXISTING 12" FM
EXISTING GROUND
97811-SAMPLE 04
e v a t i o n
Profile View of 16-Inch FM
+50
+50
C-103
165 LF PROPOSED 16" C-905 PVC FM
16" 45.00 ELBOW
STA: 55+46.73
OFF: -0.04
N: 1528892.102
E: 567729.470
18" X 16" TAPPING
SLEEVE AND VALVE
STA: 55+76.84
OFF: 0.09
N: 1528864.863
E: 567736.360
BURIED ELECTRIC
BURIED GAS
BURIED FIBER OPTIC
16" PLUG VALVE
STA: 55+71.16
OFF: 0.06
N: 1528870.544
E: 567736.342
16" 45.00 ELBOW
STA: 55+56.36
OFF: 0.06
N: 1528885.345
E: 567736.228
16" 45.00 ELBOW
(VERTICAL BEND)
STA: 55+61.38
OFF: 0.10
N: 1528880.328
E: 567736.228
16" 45.00 ELBOW
(VERTICAL BEND)
STA: 55+59.63
OFF: 0.09
N: 1528882.071
E: 567736.228
AIR RELEASE VALVE
STA: 55+66.09
OFF: 0.10
N: 1528875.618
E: 567736.263
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
G
G
G
G
G
G
G
G
BE
BE
BE
BE
BE
BE
BE
B E
B E
B E
B
E
B E
B
E
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
G
G
G
B
F
O
B
F
O
B
F
O
B
F
O
90 LF PROPOSED 16" C-905 PVC FM
16" 45.00 ELBOW
STA: 55+46.73
OFF: -0.04
N: 1528892.102
E: 567729.470
165 LF PROPOSED 16" C-905 PVC FM
16" PLUG VALVE
STA: 55+71.16
OFF: 0.06
N: 1528870.544
E: 567736.342
18" X 16" TAPPING
SLEEVE AND VALVE
STA: 55+76.84
OFF: 0.09
N: 1528864.863
E: 567736.360
16" 45.00 ELBOW
STA: 55+56.36
OFF: 0.06
N: 1528885.345
E: 567736.228
18" LINE STOP
STA: 55+76.56
OFF: 2.31
N: 1528865.129
E: 567734.141
AIR RELEASE VALVE
STA: 55+66.09
OFF: 0.13
N: 1528875.618
E: 567736.241
16" 45.00 ELBOW
(VERTICAL BEND)
STA: 55+59.63
OFF: 0.09
N: 1528882.071
E: 567736.228
16" 45.00 ELBOW
(VERTICAL BEND)
STA: 55+61.38
OFF: 0.10
N: 1528880.328
E: 567736.228
FM
-2
FM
-3
FM
-3
FM
-3
ARV-3
PV-1
FM
-3
FM
-3
00 20' 40'
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
C-104
1" = 20'
97811
CS
AR
DT
X
LAKE UNDERHILL FORCE MAIN
REPLACEMENT
LAKE UNDERHILL ROAD PLAN AND PROFILE
X
X
SCALE: 1" = 20'
NOTES:
1. EXISTING FORCE MAIN SHALL BE REMOVED WHERE NEW PIPE IS INSTALLED VIA OPEN
TRENCH AND SHALL BE DISPOSED OF MEETING ALL LOCAL ENVIRONMENTAL
REQUIREMENTS.
2. EXISTING FORCE MAIN SHALL BE GROUT-FILLED WHERE NEW PIPE IS INSTALLED VIA
DIRECTIONAL DRILL AS SHOWN IN PLANS. GROUT-FILLED PIPE SHALL BE CUT, CAPPED,
AND PLACED OUT OF SERVICE.
4. THE ESTIMATED SOD REPLACEMENT ON C-104 IS APPROXIMATELY 212 SY.
5. THE ESTIMATED SIDEWALK REPLACEMENT ON C-104 IS APPROXIMATELY 60 SY
SUGGESTED CONSTRUCTION SEQUENCING
1. CONSTRUCT THE PROPOSED 16” FM FROM THE PLUG VALVE AT STA. 48+62 TO THE
PLUG VALVE AT STA. 53+52.
2. CONSTRUCT THE PROPOSED 12” FM FROM THE TAPPING SLEEVE AT STA. 500+95 TO
THE TEE AT STA. 53+34.
3. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE TAPPING VALVE AT STA.
41+66 AND CONNECT TO THE TEE AT STATION 48+64.
4. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE BYPASS TAPPING SLEEVE
AT STA. 53+49 AND CONNECT TO THE TEE AT STA. 53+49.
5. AFTER THE NEWLY CONSTRUCTED 16” AND 12” PIPE IS TESTED AND READY TO BE
PLACED IN SERVICE, CLOSE THE EXISTING VALVE AT 41+67 AND INSTALL THE LINE STOP
ON EXISTING FM AT STA. 53+46. TAP EXISTING FM AT STA. 41+67 AND STA. 53+49 AND
CLOSE THE EXISTING VALVE JUST SOUTH OF THE TAPPING SLEEVE AT STA. 500+95.
6. CONSTRUCT REMAINING PROPOSED 16” FM.
7. AFTER ALL PROPOSED PIPING IS TESTED AND READY TO BE PLACED IN SERVICE:
a. INSTALL THE LINE STOP ON EXISTING FM AT 55+76 AND TAP EXISTING FM AT STA 55+77
b. OPEN THE EXISTING VALVE AT STA.41+67 AND CLOSE THE PLUG VALVE AT STA.
41+72
c. OPEN THE PLUG VALVE AT STA. 48+62 AND CLOSE THE PLUG VALVE AT STA 48+63
d. OPEN THE PLUG VALVE AT STA. 53+51 AND CLOSE THE PLUG VALVE AT STA. 53+48.
REMOVE 141 LF EXISTING 18" FM
EXISTING GROUND
100 SY ROADWAY CUT
INSTALL LINE STOP AND TAPPING
SLEEVE AFTER ALL PROPOSED
PIPELINE IS INSTALLED, TESTED,
AND READY TO PLACE IN SERVICE.
PROVIDE STEEL PLATES TO
PROVIDE ACCESS TO DRIVEWAY.
THE DRIVEWAY MUST BE
ACCESSIBLE AT ALL TIMES.
55 LF CURB & GUTTER REPLACEMENT
97811-SAMPLE 05
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
SUGGESTED CONSTRUCTION SEQUENCING
1. CONSTRUCT THE PROPOSED 16” FM FROM THE PLUG VALVE AT
STA. 48+62 TO THE PLUG VALVE AT STA. 53+52.
2. CONSTRUCT THE PROPOSED 12” FM FROM THE TAPPING SLEEVE AT
STA. 500+95 TO THE TEE AT STA. 53+34.
3. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE
TAPPING VALVE AT STA. 41+66 AND CONNECT TO THE TEE AT
STATION 48+64.
4. INSTALL BYPASS PIPING AND ASSOCIATED FITTINGS FROM THE
BYPASS TAPPING SLEEVE AT STA. 53+49 AND CONNECT TO THE TEE
AT STA. 53+49.
5. AFTER THE NEWLY CONSTRUCTED 16” AND 12” PIPE IS TESTED AND
READY TO BE PLACED IN SERVICE, CLOSE THE EXISTING VALVE AT
41+67 AND INSTALL THE LINE STOP ON EXISTING FM AT STA. 53+46.
TAP EXISTING FM AT STA. 41+67 AND STA. 53+49 AND CLOSE THE
EXISTING VALVE JUST SOUTH OF THE TAPPING SLEEVE AT STA.
500+95.
6. CONSTRUCT REMAINING PROPOSED 16” FM.
7. AFTER ALL PROPOSED PIPING IS TESTED AND READY TO BE PLACED
IN SERVICE:
a. INSTALL THE LINE STOP ON EXISTING FM AT 55+76 AND TAP
EXISTING FM AT STA 55+77
b. OPEN THE EXISTING VALVE AT STA.41+67 AND CLOSE THE
PLUG VALVE AT STA. 41+72
c. OPEN THE PLUG VALVE AT STA. 48+62 AND CLOSE THE PLUG
VALVE AT STA 48+63
d. OPEN THE PLUG VALVE AT STA. 53+51 AND CLOSE THE PLUG
VALVE AT STA. 53+48.
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
PROFESSIONAL ENGINEER
FLORIDA LICENSE #
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
FITTING WORKSHEET
VALVE WORKSHEET
ARV WORKSHEET
SAMPLE POINT WORKSHEET
| G-100 TO G-104-G100 |
| Sheets and Views |
| G-100 TO G-104-G100 |
| G-100 TO G-104-G101 |
| Sheets and Views |
| G-100 TO G-104-G101 |
| G-100 TO G-104-G102 |
| Sheets and Views |
| G-100 TO G-104-G102 |
| C-100 |
| Sheets and Views |
| C-100 TO C-104 Test-C-100 |
| C-100 TO C-104 |
| Sheets and Views |
| C-100 TO C-104-C-101 |
| C-100 TO C-104-C-102 |
| C-100 TO C-104-C-103 |
| C-100 TO C-104-C-104 |
| D-100 TO D-103-D-100 |
| Sheets and Views |
| D-100 TO D-103-D-100 |
| D-100 TO D-103-D-101 |
| Sheets and Views |
| D-100 TO D-103-D-101 |
| D-100 TO D-103-D-102 |
| Sheets and Views |
| D-102 |
| D-100 TO D-103-M-100 |
| Sheets and Views |
| D-100 TO D-103-M-100 |
| D-100 TO D-103-Z-100 |
| Sheets and Views |
| Z-100 |
| 2021-09-09T20:12:37-0400 | |
| Chad A Setzer |
File details come from the government source that posted it. Updated .