WYANG_CATM_EM_B-3_Drawings_3 Mar2021.pdf
PDF 42 MB Posted
- Attached to
- Construct Combat Arms Facility Federal contract opportunity
- Solicitation number
- W50S8W-21-R-0004
- Issued by
- Department of the Army National Guard
About this file
This document provides details on a federal contract solicitation for construction services. The solicitation is identified as number W50S8W-21-R-0004 and seeks to construct a new Combat Arms Emergency Management Facility at the Wyoming Air National Guard base. Interested parties must submit any Requests for Information to Desiree Santos by August 10, 2021, and site visits to review the project will be held on August 2, 2021. Responses to the solicitation are due by the dates specified, and the work will be overseen by the Department of the Army National Guard.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions and Answers DPEZ189031 CATM.pdf | ||
| Site Visit Sign In CATM.pdf | ||
| B.08 Solicitation 21R0004.pdf | ||
| Combat Arms Site Visit Entry Form.pdf | ||
| A.02 DPEZ 189031 SOW Replace CATM-EM.pdf | ||
| EXHIBIT A Performance Relevancy Questionnaire.doc | DOC document | |
| EXHIBIT C Reference Questionnaire.docx | DOCX document | |
| WYANG CATEMF 10221664 - B-3 Specifications - 2021-03-03- Complete Book.pdf | ||
| Exhibit D_Letter of Commitment.docx | DOCX document | |
| AF 3064 Construction Progress Schedule.pdf | ||
| EXHIBIT B Subcontractor Information.doc | DOC document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HDR Project No.
Date:
C o n t r a c t D r a w i n g s F o r
COMBAT ARMS TRAINING AND
EMERGENCY MANAGEMENT FACILITY
WYOMING AIR NATIONAL GUARD
PROJECT NO. DPEZ 189031
ISSUED FOR BID
VICINITY MAP
PROJECT LOCATION AND HAUL ROUTE MAP
10221664
1/22/2021
NONE
PROJECT MANAGER
HDR PROJECT NUMBER
0 1" 2"
SCALE
FILENAME
CIVIL
STRUCTURAL
ARCHITECTURAL
ELECTRICAL
MECHANICAL
FIRE PROTECTION
COMMUNICATIONS
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
SHEET
T. MATTSON
J. LENZ
S. HEANEY
J. ZAVADIL
J. LEWIS
A. NOWKA
K. JEYEONG
B
IM
/1
C H
J V
W
Y C
A T
M E
M D e s ig n
/1
C
A T
M -E
M -S
A F
.r v t
-J a n -2
G001 10221664
TOM SVOBODA
10221664_CATM-EM-SAF.rte
SHEET INDEXWYOMING ANG
PROJECT NO. DPEZ 189031
COMBAT ARMS TRAINING
AND EMERGENCY
MANAGEMENT FACILITY
SHEET INDEX
SHEET # DESCRIPTION
13 - MECHANICAL (M)
M001 MECHANICAL LEGEND
M101 HVAC PLAN
M102 HVAC PIPING PLAN
M501 MECHANICAL DETAILS
M502 MECHANICAL DETAILS
M601 MECHANICAL SCHEDULES
M602 MECHANICAL SCHEDULES
M603 MECHANICAL CONTROLS
M604 MECHANICAL CONTROLS
M605 MECHANICAL CONTROLS
M606 MECHANICAL CONTROLS
14 - PLUMBING (P)
P101 FOUNDATION PLUMBING PLAN
P102 PLUMBING PLAN
P103 PLUMBING ROOF PLAN
P401 ENLARGED PLUMBING PLAN
P501 PLUMBING DETAILS
P601 PLUMBING SCHEDULES
P901 PLUMBING WASTE AND VENT RISER DIAGRAM
P902 PLUMBING DOMESTIC WATER RISER DIAGRAM
15 - FIRE PROTECTION (F)
F001 FIRE PROTECTION NOTES AND LEGENDS
F101 FIRE PROTECTION FLOOR PLAN
F102 FIRE ALARM FLOOR PLAN
F501 FIRE PROTECTION DETAILS
F502 FIRE PROTECTION DETAILS
F503 FIRE ALARM DETAILS
F504 FIRE ALARM ANTENNA DETAILS
F601 FIRE ALARM DIAGRAMS
F602 FIRE ALARM DIAGRAMS
16 - ELECTRICAL (E)
E001 ELECTRICAL LEGEND
E101 ELECTRICAL POWER PLAN
E102 ELECTRICAL LIGHTING PLAN
E103 LIGHTNING PROTECTION / GROUNDING PLAN
E501 ELECTRICAL ONE-LINE DIAGRAM AND DETAILS
E502 ELECTRICAL DETAILS
E601 ELECTRICAL SCHEDULES
E602 ELECTRICAL SCHEDULES
E603 ELECTRICAL SCHEDULES
17 - TELECOMMUNICATIONS (T)
E002 LOW VOLTAGE / ELECTRICAL LEGEND 2
EC101 TELECOMMUNICATIONS FLOOR PLAN
EC401 TELECOMMUNICATIONS ENLARGED PLAN
EC501 TELECOMMUNICATIONS DETAILS
EC502 TELECOMMUNICATIONS DETAILS
18 - SECURITY
EY101 SECURITY FLOOR PLAN
SHEET INDEX
SHEET # DESCRIPTION
00 - GENERAL (G)
G000 COVER SHEET
G001 SHEET INDEX
G002 ABBREVIATIONS
G003 GENERAL LEGEND
G004 GENERAL CIVIL LEGEND
G005 CODE ANALYSIS
G006 CODE COMPLIANCE SITE PLAN
G007 LIFE SAFETY PLAN
01 - DEMOLITION (X)
X101 EXISTING BUILDING 32 DEMOLITION PLAN
X102 EXISTING BUILDING 32 DEMOLITION ELEVATIONS
05 - CIVIL (C)
C101 EXISTING SITE SURVEY
C102 SITE DEMOLITION PLAN
C103 SITE UTILITY PLAN
C104 SITE LAYOUT PLAN
C105 SITE GRADING AND DRAINAGE PLAN
C106 SITE EROSION AND SEDIMENT CONTROL PLAN
C107 PAVEMENT JOINT PLAN
C108 PARKING AREA PLAN
C501 CIVIL DETAILS
C502 CIVIL DETAILS
C503 CIVIL DETAILS
08 - STRUCTURAL (S)
S001 STRUCTURAL GENERAL NOTES SHEET
S101 FOUNDATION PLAN
S102 ROOF FRAMING PLAN
S301 CONCRETE DETAILS
S302 CONCRETE DETAILS
S303 FOUNDATION DETAILS
S304 FOUNDATION DETAILS
S401 MASONRY DETAILS
S402 MASONRY DETAILS
S501 STEEL DETAILS
S502 ROOF FRAMING DETAILS
S503 ROOF FRAMING DETAILS
S504 ROOF FRAMING DETAILS
S601 DIAGRAMS
S602 STRUCTURAL TRUSS LOAD DIAGRAMS
09 - ARCHITECTURAL (A)
A101 FLOOR PLAN
A102 REFLECTED CEILING PLAN
A103 FURNITURE AND EQUIPMENT PLAN
A104 FURRED WALLS PLAN (ABI 3)
A105 ROOF PLAN
A201 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
A302 WALL SECTIONS
A303 WALL SECTIONS AND DETAILS
A401 ENLARGED PLANS AND INTERIOR ELEVATIONS
A402 TOILET ACCESSORY SCHEDULE AND DETAILS
A501 DETAILS
A502 DETAILS
A503 DETAILS
A504 WINDOW AND WALL TYPES
A601 SCHEDULES, DOOR AND FRAME TYPES
A901 ISOMETRIC VIEWS
1/22/2021 ISSUED FOR BID
TOP OF BOLT, TOP OF BANK,
TOP OF BEAM, TOP OF BERM
TOP OF CURB, TOP OF CONCRETE
TOP OF DUCT
TOP OF FOOTING
TOP OF GRATING
TOLERANCE, TOP OF LEDGER
TOP OF MASONRY
TOP OF PLATE
TOPOGRAPHY
TOP OF SLAB, TOP OF STEEL,
TOE OF SLOPE
TOP OF WALL
TOILET PARTITION, TELEPHONE POLE,
TOE PLATE, TRAP PRIMER
TOILET PAPER DISPENSER
TOPPING, THROUGH PLATE GIRDER
TRANSOM
TRANSITION
TRENCH DRAIN
TYPICAL
URINAL
UNDERGROUND
ULTIMATE
UNFINISHED
UNLESS NOTED OTHERWISE
UTILITY
VENT, VELOCITY, VOLT
VOLT AMPERE
VACUUM
VARNISH, VARIABLE,
VOLT AMPERES REACTIVE
VAPOR BARRIER, VINYL BASE,
VALVE BOX
VERTICAL CURVE
VITRIFIED CLAY PIPE
VINYL COMPOSITION TILE,
VERTICAL CENTERLINE
VELOCITY
VENTILATION
VERTICAL
VERTICAL REINFORCING
VERTICAL GRAIN
VERIFY IN FIELD
VINYL
VOLUME
VERTICAL POINT OF CURVATURE
VERTICAL POINT OF INTERSECTION
VERTICAL POINT OF TANGENCY
VERSUS, VAPOR SEAL
VENT THROUGH ROOF
VINYL WALL COVERING
WITH
WITHOUT
WATT, WEST, WIDE, WINDOW, WIRE,
WIDE FLANGE BEAM
WOOD BASE
WATER CLOSET, WATER COLUMN
WOOD, WIDTH
WIDE FLANGE, WASH FOUNTAIN
WIRE GLASS, WATER GAGE
WALL HYDRANT, WEEP HOLE
WROUGHT IRON
WATER LEVEL
WELDED
WIRE MESH
WEATHERPROOF
WATERSTOP, WATER SURFACE
WAINSCOT
WEIGHT, WATER TIGHT
WATERPROOF, WORKING POINT
WELDED WIRE FABRIC
EXPLOSION-PROOF
EXTRA STRONG
CROSS SECTION
DOUBLE EXTRA STRONG
YARD HYDRANT
YIELD STRENGTH
TOB
TOC
TOD
TOF
TOG
TOL
TOM
TOP
TOPO
TOS
TOW
TP
TPD
TPG
TR
TRANS
TRD
TYP
U
UG
ULT
UNFN
UNO
UTIL
V
VA
VAC
VAR
VB
VC
VCP
VCT
VEL
VENT
VERT
VERTS
VG
VIF
VIN
VOL
VPC
VPI
VPT
VS
VTR
VWC
W/
W/O
W
WB
WC
WD
WF
WG
WH
WI
WL
WLD
WM
WP
WS
WSCT
WT
WTHP
WWF
XP
XS
XSECT
XXS
YH
YS
REMOVE AND REPLACE
REMOVE AND SALVAGE
RADIUS, REGISTER, RISER
RETURN AIR
RESILIENT BASE, ROCK BERM
RECEPTACLE
ROOF DRAIN
RECESS
RECEIVED
RECTANGULAR
REDUCER
REFERENCE
REINFORCING
REMOVE
REQUIRED
RESILIENT
RETAINING, RETURN
REVISION, REVERSE
RESILIENT FLOORING
ROOFING
REFLECTED, REFLECTOR
ROUGH
RIGID GALVANIZED STEEL
RELIEF HOOD, RIGHT HAND,
RELATIVE HUMIDITY
REQUIRED LAP
RELIEF AIR
ROUND
RUNNING
ROUGH OPENING
RIGHT-OF-WAY
REVOLUTIONS PER MINUTE
RAILROAD
ROCK SLOPE PROTECTION
RIGHT
RESILIENT VINYL TILE
READY
SOUTH, SINK
SUPPLY AIR
SOUND-ABSORBING MASONRY UNIT
SANITARY
SPLASH BLOCK
SOLID CORE
SCHEDULE
SCHEMATIC
SCREEN
STEEL/ALUMINUM EDGE
SECONDARY, SECONDS
SECTION
SEPARATE
SQUARE FOOT, SILT FENCE
SHEET GLASS, SEALANT GROOVE
SHOWER
SHEET
SHEATHING
SILENCE
SIMILAR
SLAB JOINT
SLOPE, STEEL LINTEL
SLOTTED
SLEEVE
SEAMLESS
SLAB ON GRADE
SOUNDPROOF, STANDPIPE
SPACING
SPECIFICATION
SUPPLY
SINGLE POLE SINGLE THROW
SET POINT
SQUARE
SHORT RADIUS
SERVICE SINK
STAINLESS STEEL
STREET
STATION
STANDARD
STIFFENER
STIRRUP
STEEL
STORAGE
STRUCTURAL, STRAIGHT
SUBSTITUTE
SUCTION
SUSPENDED
SQUARE YARD
SYMBOL
SYMMETRICAL
SYNTHETIC
SYSTEM
TOP AND BOTTOM
TONGUE AND GROOVE
TILE, TREAD
TOILET ACCESSORY, TEMPERED AIR
TANGENT
TEMPORARY BENCHMARK
TEMPORARY CONSTRUCTION EASEMENT
TROWELED EPOXY FLOORING
TEMPORARY, TEMPERATURE
THREAD
THICK
THRESHOLD
TACK BOARD
R&R
R&S
R
RA
RB
RCPT
RD
REC
RECD
RECT
RED
REF
REINF
REM
REQD
RESIL
RET
REV
RF
RFG
RFL
RGH
RGS
RH
RL
RLFA
RND
RNG
RO
ROW
RPM
RR
RSP
RT
RVT
RY
S
SA
SAMU
SAN
SB
SC
SCH
SCHEM
SCN
SE
SEC
SECT
SEP
SF
SG
SH
SHT
SHTG
SIL
SIM
SJ
SL
SLTD
SLV
SMLS
SOG
SP
SPA
SPEC
SPLY
SPST
SPT
SQ
SR
SS
SST
ST
STA
STD
STIF
STIR
STL
STOR
STR
SUB
SUC
SUSP
SY
SYM
SYMM
SYN
SYS
T&B
T&G
T
TA
TAN
TBM
TCE
TEF
TEMP
THD
THK
THRESH
TKBD
NORTH, NEUTRAL
NOT APPLICABLE
NATURAL, NATIONAL
NORMALLY CLOSED
NEGATIVE
NEAR FACE, NON-FUSED
NOT IN CONTRACT
NORMALLY OPEN, NUMBER
NOMINAL
NOMINAL PIPE SIZE
NATIONAL PIPE THREAD
NEAR SIDE
NOT TO SCALE
NORMAL WATER LEVEL
OUT TO OUT
OUTSIDE AIR, OVERALL
ON CENTER
OVER CURRENT PROTECTION DEVICE
OUTSIDE DIAMETER
OPEN END DUCT
OUTSIDE FACE, OFFICE FURNISHING
OWNER FURNISHED CONTRACTOR
INSTALLED
OWNER FURNISHED OWNER INSTALLED
ORIGINAL GROUND
OVERHEAD
OPENING
OPPOSITE
OPTIONAL
OUTSIDE RADIUS
OVERFLOW ROOF DRAIN
ORIGINAL
OVERFLOW
OVERHANG
OUNCE
PAINT
PUBLIC ADDRESS
PARALLEL, PARAPET
PANIC BAR, PULL BOX
PARTICLE BOARD
POINT OF CURVE, PIECE, PRECAST
POINT OF COMPOUND CURVATURE
POUNDS PER CUBIC FOOT
PERCENT
PLAIN END
PEDESTAL
PENETRATION
PERFORATED
PERMANENT
PERPENDICULAR
POWER FACTOR
PREFACED MASONRY UNIT
PHASE
POINT OF INTERSECTION
PACKAGE
PLATE, PROPERTY LINE,
PRECAST LINTEL
PLASTER
PLATFORM
PLUMBING
POUNDS PER LINEAR FOOT
PNEUMATIC
POLISH
POSITIVE, POSITION
POLYPROPYLENE, POWER POLE
POINT OF REVERSE CURVATURE
PREFINISHED
PREFABRICATED
PRELIMINARY
PREPARE
PRESSURE
PRIMARY
PROPERTY, PROPOSED
PROTECTION
PIPE SUPPORT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCH GAGE
PRESTRESSED
POINT, POINT OF TANGENCY
PARTITION
POLYVINYL CHLORIDE, POINT OF
VERTICAL CURVE
PAVEMENT
PLYWOOD
PLYWOOD WEB JOIST
PIEZOMETER
RATE OF FLOW
QUARRY TILE
QUARTER
QUANTITY
QUALITY
N
NA
NAT
NC
NEG
NF
NIC
NO
NOM
NPS
NPT
NS
NTS
NWL
O TO O
OA
OC
OCPD
OD
OED
OF
OFCI
OFOI
OG
OH
OPNG
OPP
OPT
OR
ORD
ORIG
OVFL
OVHG
OZ
P
PA
PAR
PB
PBD
PC
PCC
PCF
PCT
PE
PED
PEN
PERF
PERM
PERP
PF
PFMU
PH
PI
PKG
PL
PLAS
PLAT
PLBG
PLF
PNEU
POL
POS
PP
PRC
PREF
PREFAB
PRELIM
PREP
PRES
PRI
PROP
PROT
PS
PSF
PSI
PSIA
PSIG
PST
PT
PTN
PVC
PVMT
PWD
PWJ
PZ
Q
QT
QTR
QTY
QUAL
ID
IE
IF
IH
IMP
IN
INC
INF
INSTR
INSUL
INT
INTR
INV
IPS
IPT
IR
IRR
ISO
JB
JCT
JF
JST
JT
K
KB
KCMIL
KD
KO
KSI
KW
L
LAD
LAM
LATL
LB
LCTB
LDG
LDR
LE
LF
LG
LH
LIN
LIQ
LLH
LLV
LMLU
LNG
LOC
LP
LPS
LR
LT
LTD
LTG
LTL
LTNG
LV
LVL
LVR
LW
LWC
LWL
MA
MACH
MAINT
MAN
MATL
MAX
MB
MBR
MC
MCB
MCJ
MDMJ
MECH
MED
MFR
MH
MIN
MIR
MISC
MJ
ML
MLO
MMB
MO
MOD
MON
MPT
MRGWB
MS
MSL
MT
MU
MULL
MV
MW
INSIDE DIAMETER, INTERIOR DIMENSION
INVERT ELEVATION, FOR EXAMPLE
INSIDE FACE
INTAKE HOOD
IMPACT
INCH
INCLUDE, INCANDESCENT
INFLUENT
INSTRUMENTATION
INSULATION
INTERIOR, INTERSECTION
INTERMEDIATE, INTERIOR
INVERT
IRON PIPE SIZE
INTERNAL PIPE THREAD
INSIDE RADIUS, IRON ROD
IRRIGATION
ISOMETRIC
JUNCTION BOX
JUNCTION
JOINT FILLER
JOIST
JOINT
KIP
KNEE BRACE
THOUSAND CIRCULAR MILS
KNOCK DOWN
KNOCK OUT
KIPS PER SQUARE INCH
KILOWATT
ANGLE, LENGTH, LAVATORY, LINTEL
LADDER
LAMINATE
LATERAL
LAG BOLT, POUND
LIQUID CHALK AND TACK BOARD
LANDING
LEADER
LIFTING EYE
LINEAR FOOT
LONG
LEFT HAND
LINEAR
LIQUID
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LIQUID MARKER LECTURE UNIT
LONGITUDINAL
LOCATION
LOW POINT
LOW-PRESSURE SODIUM
LONG RADIUS
LEFT
LIMITED
LIGHTING
LINTEL
LIGHTNING
LOW VOLTAGE
LAMINATED VENEER LUMBER
LOUVER
LIGHTWEIGHT
LIGHTWEIGHT CONCRETE
LOW WATER LEVEL
MIXED AIR
MACHINED
MAINTENANCE
MANUAL
MATERIAL
MAXIMUM
MACHINE BOLT
MEMBER
MECHANICAL CONTRACTOR,
MECHANICAL COUPLING,
MOMENT CONNECTION
METAL CORNER BEAD
MASONRY CONTROL JOINT
MODIFIED DOUBLE MECHANICAL JOINT
MECHANICAL
MEDIUM
MANUFACTURER
MANHOLE, METAL HALIDE
MINIMUM
MIRROR
MISCELLANEOUS
MECHANICAL JOINT
MASONRY LINTEL
MAIN LUGS ONLY
MEMBRANE
MASONRY OPENING
MODULAR, MODIFY
MONUMENT
MALE PIPE THREAD
MOISTURE-RESISTANT
GYPSUM WALLBOARD
MOP SINK
MEAN SEA LEVEL
MOUNT
MASONRY UNIT
MULLION
MEDIUM VOLTAGE
MONITORING WELL
F TO F
F&B
FAB
FB
FBD
FBG
FBM
FBO
FC
FCA
FD
FDC
FDR
FDTN
FE
FEC
FES
FEXT
FF
FG
FH
FIG
FIN
FJT
FL
FLEX
FLG
FLOR
FLR
FLS
FN
FO
FOB
FOC
FOF
FOM
FOS
FOT
FPT
FR
FRP
FRTM
FS
FT
FTG
FUR
FURN
FUT
FV
FW
FWD
FWE
FXTR
G
GA
GAL
GALV
GB
GC
GD
GEN
GFCI
GFMU
GG
GJ
GL
GLB
GND
GP
GR
GRTG
GSB
GT
GVL
GW
GWB
GYP
H
HB
HBD
HC
HD
HDR
HDW
HEX
HGR
HH
HID
HM
HORIZ
HP
HPC
HPS
HPT
HR
HS
HSS
HT
HTG
HV
HVAC
HWD
HWL
HYD
HZ
FACE TO FACE
FACE AND BYPASS
FABRICATE
FLOOR BEAM
FIBERBOARD
FIBERGLASS
BOARD FOOT MEASURE
FURNISHED BY OWNER
FLUSHING CONNECTION
FLANGED COUPLING ADAPTER
FLOOR DRAIN
FLEXIBLE DUCT CONNECTION
FEEDER
FOUNDATION
FLANGED END
FIRE EXTINGUISHER CABINET
FLARED END SECTION
FIRE EXTINGUISHER
FAR FACE, FACTORY FINISH, FLAT FACE
FINISHED GRADE
FIRE HYDRANT
FIGURE
FINISH
FLUSH JOINT
FLOW, FLOW LINE
FLEXIBLE
FLANGE
FLUORESCENT
FLOOR
FLASHING, FLUSH
FENCE
FINISHED OPENING
FLAT ON BOTTOM
FACE OF CONCRETE, FACE OF CURB
FACE OF FINISH
FACE OF MASONRY
FACE OF STUDS
FLAT ON TOP
FEMALE PIPE THREAD
FRAME
FIBERGLASS REINFORCED PLASTIC
FIRE RETARDANT TREATED MATERIAL
FLOOR SINK, FAR SIDE
FEET, FOOT
FOOTING, FITTING
FURRED, FURRING
FURNITURE, FURNISH
FUTURE
FACE VELOCITY
FIELD WELD, FIRE WALL
FORWARD
FURNISHED WITH EQUIPMENT
FIXTURE
GRILLE, GROUND
GAGE (METAL THICKNESS)
GALLON
GALVANIZED
GRAB BAR, GRADE BREAK
GROOVED COUPLING
GUARD
GENERAL
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FACE MASONRY UNIT
GUTTER GRADE
GROOVED JOINT
GLASS
GLASS BLOCK, GLULAM BEAM
GROUND
GUY POLE
GRADE
GRATING
GYPSUM SHEATHING BOARD
GREASE TRAP
GRAVEL
GUY WIRE
GYPSUM WALLBOARD
GYPSUM HARDBOARD
HIGH
HOSE BIBB
HARDBOARD
HANDICAPPED, HOLLOW CORE, HORIZONTAL
CURVE, HORIZONTAL CENTERLINE
HEAD, HOT DIP
HEADER
HARDWARE
HEXAGONAL
HANGER
HANDHOLE
HIGH-INTENSITY DISCHARGE
HOLLOW METAL
HORIZONTAL
HIGH POINT, HORSEPOWER
HORIZONTAL POINT OF CURVATURE
HIGH-PRESSURE SODIUM
HORIZONTAL POINT OF TANGENCY
HOSE REEL, HOUR
HEADED STUD, HIGH STRENGTH
HOLLOW STRUCTURAL SHAPE
HEIGHT
HEATING
HIGH VOLTAGE
HEATING, VENTILATING AND
AIR CONDITIONING
HARDWOOD
HIGH WATER LEVEL
HYDRAULIC
HERTZ, CYCLES PER SECOND
CLKG
CLR
CMH
CMP
CMU
CO
COL
COM
COMB
COMM
COMP
CON
CONC
CONN
CONST
CONT
COOR
CORR
CP
CPLG
CRL
CSC
CSK
CSS
CT
CTJ
CTR
CTRL
CVT
CU
CW
CY
d
D
DB
DBA
DBL
DC
DEG
DEG C
DEG F
DEMO
DEP
DEPT
DET
DI
DIA
DIAG
DIFF
DIM
DISCH
DIST
DIV
DL
DMJ
DMPF
DN
DO
DP
DPDT
DPST
DS
DT
DUP
DWG
DWL
DWR
E
EA
EC
ECC
ED
EDB
EE
EF
EFF
EHH
EIFS
EJ
EL
ELEC
EMBD
EMER
EMH
ENCL
ENGR
ENTR
EOP
EQ
EQUIP
EQUIV
ES
ESEW
EST
EW
EWC
EWEF
EWTB
EXC
EXH
EXP
EXST
EXT
CAULKING
CLEAR
COMMUNICATION MANHOLE
CORRUGATED METAL PIPE
CONCRETE MASONRY UNIT
CLEANOUT, CONCRETE OPENING
COLUMN
COMMON
COMBINATION
COMMUNICATION
COMPOSITION, COMPRESSIBLE,
COMPOSITE
CONCENTRIC
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
COORDINATE
CORROSIVE, CORRUGATED
CHECKER PLATE, CONTROL POINT
COUPLING
CORROSION-RESISTANT LINING
COMPRESSION SLEEVE COUPLING
COUNTERSINK
CLINIC SERVICE SINK
CERAMIC TILE
CONTRACTION JOINT
CENTER
CONTROL
CULVERT
COPPER, CUBIC
CLOCKWISE
CUBIC YARD
PENNY (NAIL MEASURE)
DEEP, DIFFUSER, DRAIN
DUCT BANK, DECIBEL, DRY BULB
DEFORMED BAR ANCHOR
DOUBLE
DIRECT CURRENT
DEGREE
DEGREE CENTIGRADE
DEGREE FAHRENHEIT
DEMOLITION
DEPRESSED
DEPARTMENT
DETAIL
DROP INLET, DUCTILE IRON, DIGITAL INPUT
DIAMETER
DIAGONAL, DIAGRAM
DIFFERENTIAL, DIFFERENCE
DIMENSION
DISCHARGE
DISTANCE, DISTRIBUTION
DIVISION
DEAD LOAD
DOUBLE MECHANICAL JOINT
DAMP PROOFING
DOWN
DISSOLVED OXYGEN, DIGITAL OUTPUT, DITTO
DEPTH
DOUBLE POLE, DOUBLE THROW
DOUBLE POLE, SINGLE THROW
DOWN SPOUT
DOUBLE TEE, DRIP TRAP ASSEMBLY
DUPLICATE
DRAWING
DOWEL
DRAWER
EAST
EACH, EXHAUST AIR
ELECTRICAL CONTRACTOR
ECCENTRIC
EQUIPMENT DRAIN
ELECTRICAL DUCT BANK
EACH END
EACH FACE
EFFLUENT, EFFICIENCY
ELECTRICAL HANDHOLE
EXTERIOR INSULATION &
FINISH SYSTEM
EXPANSION JOINT
ELBOW, ELEVATION
ELECTRICAL
EMBEDDED
EMERGENCY
ELECTRICAL MANHOLE
ENCLOSURE
ENGINEER
ENTRANCE
EDGE OF PAVEMENT
EQUAL
EQUIPMENT
EQUIVALENT
EACH SIDE, EQUAL SPACE,
EMERGENCY SHOWER
EMERGENCY SHOWER AND EYE WASH
ESTIMATE
EACH WAY, EMERGENCY
EYE/FACE WASH
ELECTRIC WATER COOLER
EACH WAY, EACH FACE
EACH WAY, TOP AND BOTTOM
EXCAVATION
EXHAUST
EXPANSION, EXPOSED
EXISTING
EXTERIOR, EXTERNAL, EXTENSION
A/C
A/E
A
AB
ABAN
ABC
ABT
AC
ACK
ACP
ACST
AD
ADDL
ADH
ADJ
AF
AFF
AFG
AGGR
AI
AIC
ALIG
ALT
ALUM
AM
AMB
ANC
AO
AP
APRX
APVD
ARCH
ASSY
AT
ATC
ATM
AUTO
AUX
AVE
AVG
AWG
AWT
B TO B
BAL
BBD
BC
BD
BE
BF
BITUM
BKG
BL
BLDG
BLK
BLKG
BM
BOC
BOD
BOG
BOL
BOP
BOR
BOT
BOU
BP
BRG
BRGP
BRKT
BS
BTU
BTW
BTWLD
BU
BUR
BW
BYP
CTOC
C&G
C
CAB
CAP
CAT
CAV
CB
CCB
CCW
CDF
CE
CER
CF
CFL
CHBD
CHD
CHFR
CHH
CI
CIP
CIPB
CIRC
CJ
CKT
CL
CLG
AIR CONDITIONING
ARCHITECT/ENGINEER
AMPERE
ANCHOR BOLT
ABANDON
AGGREGATE BASE COURSE
ABOUT
ALTERNATING CURRENT
ACKNOWLEDGE
ACOUSTIC CEILING PANEL,
ASPHALTIC CONCRETE PAVEMENT
ACOUSTIC
ADDENDUM, AREA DRAIN
ADDITIONAL
ADHESIVE
ADJUSTABLE, ADJACENT
AMP FRAME, AMP FUSE
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
AGGREGATE
AREA INLET, ANALOG INPUT
AMPS INTERRUPTING CAPACITY
ALIGNMENT
ALTERNATE, ALTITUDE
ALUMINUM
ACOUSTICAL MATERIAL
AMBIENT
ANCHOR
ANALOG OUTPUT
ACCESS PANEL
APPROXIMATE
APPROVED
ARCHITECTURAL
ASSEMBLY
ACOUSTICAL TILE, AMP TRIP
ACOUSTICAL TILE CEILING
ATMOSPHERE
AUTOMATIC
AUXILIARY
AVENUE
AVERAGE
AMERICAN WIRE GAGE
ACOUSTICAL WALL TILE
BACK TO BACK
BALANCE
BULLETIN BOARD
BASE CABINET, BOTTOM CHORD,
BOLT CENTER, BOLT CIRCLE
BOARD
BOTH ENDS, BELL END
BOTH FACES, BOTTOM FACE,
BLIND FLANGE, BOARD FEET
BITUMINOUS
BACKING
BASE LINE
BUILDING
BLOCK
BLOCKING
BENCHMARK, BEAM
BACK OF CURB
BOTTOM OF DUCT
BOTTOM OF GRILLE
BOTTOM OF LOUVER, BOLLARD
BOTTOM OF PIPE
BOTTOM OF REGISTER
BOTTOM
BOTTOM OF UNIT
BASE PLATE
BEARING
BEARING PLATE
BRACKET
BOTH SIDES
BRITISH THERMAL UNIT
BETWEEN
BUTT WELD
BELL UP, BUILT-UP
BUILT-UP ROOFING
BOTH WAYS
BYPASS
CENTER TO CENTER
CURB AND GUTTER
CHANNEL SHAPE, CENTIGRADE, CONDUIT
CABINET
CAPACITY
CATALOG, CATEGORY
CAVITY
CATCH BASIN
CONCRETE BLOCK
COUNTER CLOCKWISE
CONTROLLED-DENSITY FILL
CONCRETE EDGE
CERAMIC
CUBIC FEET (FOOT)
COUNTER FLASHING
CHALKBOARD
CHORD
CHAMFER
COMMUNICATION HANDHOLE
CURB INLET
CAST-IN-PLACE
CONCRETE INTERLOCKING PAVER
BALLAST
CIRCULATION, CIRCULAR
CONSTRUCTION JOINT
CIRCUIT
CENTERLINE, CLASS, CLOSE
CEILING
GENERAL NOTES:
THESE ABBREVIATIONS APPLY TO THE ENTIRE SET
OF CONTRACT DRAWINGS.
1.
LISTING OF ABBREVIATIONS DOES NOT IMPLY
THAT ALL ABBREVIATIONS ARE USED IN THE
CONTRACT DRAWINGS.
2.
ABBREVIATIONS SHOWN ON THIS SHEET INCLUDE
VARIATIONS OF A WORD. FOR EXAMPLE, "MOD" MAY
MEAN MODIFY OR MODIFICATION, "INC" MAY MEAN
INCLUDED OR INCLUDING, AND "REINF" MAY MEAN
REINFORCE OR REINFORCING.
3.
SEE INSTRUMENTATION AND GENERAL LEGEND
SHEETS FOR PROJECT-SPECIFIC EQUIPMENT AND
PIPING SYSTEM ABBREVIATIONS.
4.
PVC-RGS PVC COATED RGS
NONE
PROJECT MANAGER
HDR PROJECT NUMBER
0 1" 2"
SCALE
FILENAME
CIVIL
STRUCTURAL
ARCHITECTURAL
ELECTRICAL
MECHANICAL
FIRE PROTECTION
COMMUNICATIONS
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
SHEET
T. MATTSON
J. LENZ
S. HEANEY
J. ZAVADIL
J. LEWIS
A. NOWKA
K. JEYEONG
B
IM
/1
C H
J V
W
Y C
A T
M E
M D e s ig n
/1
C
A T
M -E
M -S
A F
.r v t
-J a n -2
G002 10221664
TOM SVOBODA
10221664_CATM-EM-SAF.rte
ABBREVIATIONSWYOMING ANG
PROJECT NO. DPEZ 189031
COMBAT ARMS TRAINING
AND EMERGENCY
MANAGEMENT FACILITY
X
X
X
X
XXX
X
ROOM
NAME
XX-XX
EQUIPMENT IDENTIFICATION
ALTERNATIVE 2
ALTERNATIVE 1
PIPING
GENERAL NOTES:
SHEET TYPE DESIGNATOR
DISCIPLINE DESIGNATOR & DISCIPLINE ORDER
AREA DESIGNATION
EXAMPLE
ARCHITECTURAL
KEY NOTE DESIGNATION
PLAN TITLE
SECTION CUT MARKER
DETAIL MARKER
MULTIPLE ELEVATION OR PHOTO MARKER
DETAIL MARKER
SECTION TITLE
ELEVATION TITLE
DETAIL TITLE
FULL BUILDING SECTION CUT MARKER
1/4" = 1'-0"
X
XXX 3/8" = 1'-0"
XXX
XXXXXX
X
XXX 1/4" = 1'-0"
X
XXX
X
XXX 3" = 1'-0"
A
EQUIPMENT NUMBER
PUMP 23
INDICATES PUMP
EXAMPLEFIGURE
PUMP 23
BUILDING 20
INDICATES PUMP
EXAMPLEFIGURE
36"LINE SIZE
PLANT EFFLUENTSERVICE
EXAMPLE36"-PLEFIGURE
NPWP2023
NPWP-23
GRAVITY THICKENER ARCHITECTURAL SECTION, DRAWING 01
GENERAL (SYMBOLS, LEGENDS)
PLANS
ELEVATIONS
SECTIONS
LARGE SCALE VIEWS
DETAILS
SCHEDULES AND DIAGRAMS
PROFILES
3D REPRESENTATIONS
GENERAL
SURVEYING/MAPPING
DEMOLITION
CIVIL
MULTI-DISCIPLINE
STRUCTURAL
ARCHITECTURAL
PROCESS
MECHANICAL (HVAC)
PLUMBING
ELECTRICAL
INSTRUMENTATION
TO BE EDITED ON AN A PROJECT BASIS. TO BE DETERMINED BY
THE PROJECT MANAGER, THEN ADDED TO THE GENERAL
LEGEND.
EXAMPLE:
01 BUILDING OR AREA NAME
02 BUILDING OR AREA NAME
03 BUILDING OR AREA NAME
G V X C U S A D M P E Y
SERVICE
ABBREVIATION
EQUIPMENT
ABBREVIATION
BUILDING
OR
STRUCTURE
NUMBER
EQUIPMENT NUMBER
INDICATES
NON-POTABLE WATER
INDICATES
NON-POTABLE WATER
SERVICE
ABBREVIATION
EQUIPMENT
ABBREVIATION
KEY NOTE NUMBER
LOUVER
WINDOW TYPE
WALL TYPE
COLUMN GRID LINE
ROOM NUMBER
DOOR NUMBER
ACCESSORY, FURNITURE,
AND MISCELLANEOUS
EQUIPMENT IDENTIFIER
ARROW INDICATES
DIRECTION OF PLAN
NORTH
4-HOUR FIRE RATED WALL
3-HOUR FIRE RATED WALL
2-HOUR FIRE RATED WALL
1-HOUR FIRE RATED WALL
COLUMN GRID LINE/CENTERLINE
FOR REFERENCING DETAILS BOUND IN
SPECIFICATIONS OR SEPARATE VOLUME.
SHEET WHERE SECTION
IS LOCATED
SHEET WHERE SECTION
VIEW IS FIRST CUT *
SHEET WHERE DETAIL
IS LOCATED *
ELEVATION
IDENTIFICATION NUMBER
SHEET WHERE POINT OF VIEW
MARKER CAN BE FOUND *
* EXCEPTIONS WHERE THE SHEET NUMBER IS REPLACED BY A DASH (-).
1) FOR COMMON DETAILS, SECTIONS, ELEVATIONS OR DETAILS
THAT ARE CUT OR CALLED OUT ON MULTIPLE SHEETS.
2) SECTIONS, ELEVATIONS OR DETAILS THAT ARE LOCATED ON THE
SAME SHEET THEY ARE CUT OR CALLED OUT ON.
ARROW INDICATES POINT OF
VIEW ELEVATION
INDICATES SHEET WHERE
ELEVATION IS LOCATED
FOR REFERENCING DETAILS INCLUDED IN DRAWING SET.
X
XX
X
SECTION LETTER
FLAG INDICATES DIRECTION
OF SECTION CUT
SECTION LETTER
DETAIL NUMBER
SHEET WHERE DETAIL
IS LOCATED *
DETAIL NUMBER
ELEVATION NUMBER
SHEET WHERE
SECTION IS LOCATED
SECTION LETTER
TARGET ELEVATION
ARROW INDICATES
DIRECTION OF SECTION
CUT
IDENTIFICATION SYMBOLOGY SHEET NAMING CONVENTION
GENERAL LINE SYMBOLOGY
GENERAL SYMBOLOGY
PLAN
SECTION
DETAIL
ELEVATIONX
XXX
X
XXX
MATERIALS IN PLAN/SECTION
RIPRAP (PLAN AND/OR SECTION)
WEEP JOINT MORTAR
PROTECTION SYSTEM (SECTION)
SOD (SECTION)
FILTER POINT MAT (PLAN)
GRATING (PLAN)
PARTICLE BOARD (SECTION)
ORIENTED STRAND BOARD (SECTION)
GLULAM LUMBER (SECTION)
FINISHED WOOD (SECTION)
BRICK MASONRY (PLAN AND/OR SECTION)
ACOUSTICAL CEILING TILE (SECTION)
PLYWOOD (SMALL-SCALE SECTION)
GROUT (SECTION)
ASPHALT (LARGE-SCALE SECTION)
DEMOLITION (PLAN AND/OR SECTION)
CONCRETE (PLAN AND/OR SECTION)
GRANULAR FILL (SECTION)
EARTH (SECTION)
GRATING (SECTION)
CHECKERED PLATE (PLAN)
BATT INSULATION (SECTION)
WOOD - CONTINUOUS (SECTION)
METAL (SECTION)
RIGID INSULATION (SECTION)
WOOD - BLOCKING (SECTION)
PLYWOOD (LARGE-SCALE SECTION)
GYPSUM BOARD (SECTION)
SAND (SECTION)
CONCRETE MASONRY (PLAN
AND/OR SECTION)
PRECAST CONCRETE (PLAN
AND/OR SECTION)
ASPHALT (PLAN OR SMALL-SCALE SECTION)
X
XXX BUILDING OR AREA 02
SHEET TYPE DESIGNATOR
SHEET NUMBER
DISCIPLINE DESIGNATOR
BUILDING OR AREA DESIGNATION
EXAMPLE
0 2
A
0 1
0 2 A 3 0 1
ARCHITECTURA
L
SECTIONS
SHEET 01
SINGLE ELEVATION OR PHOTO MARKER
X
XXX
X
XXX
ARROW INDICATES
POINT OF VIEW
SHEET WHERE ELEVATION
IS LOCATED *
INTERIOR EXTERIOR
ELEVATION NUMBER
NORTH ARROW
THIS IS A STANDARD SHEET SHOWING
COMMON SYMBOLOGY. ALL SYMBOLS ARE
NOT NECESSARILY USED ON THIS PROJECT.
SCREENING OR SHADING OF WORK IS USED
TO INDICATE EXISTING COMPONENTS OR TO
DE-EMPHASIZE PROPOSED IMPROVEMENTS TO
HIGHLIGHT SELECTED TRADE WORK. REFER
TO CONTEXT OF EACH SHEET FOR USAGE.
1.
2.
NONE
PROJECT MANAGER
HDR PROJECT NUMBER
0 1" 2"
SCALE
FILENAME
CIVIL
STRUCTURAL
ARCHITECTURAL
ELECTRICAL
MECHANICAL
FIRE PROTECTION
COMMUNICATIONS
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
SHEET
T. MATTSON
J. LENZ
S. HEANEY
J. ZAVADIL
J. LEWIS
A. NOWKA
K. JEYEONG
B
IM
/1
C H
J V
W
Y C
A T
M E
M D e s ig n
/1
C
A T
M -E
M -S
A F
.r v t
-J a n -2
G003 10221664
TOM SVOBODA
10221664_CATM-EM-SAF.rte
GENERAL LEGENDWYOMING ANG
PROJECT NO. DPEZ 189031
COMBAT ARMS TRAINING
AND EMERGENCY
MANAGEMENT FACILITY
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
WYOMING ANG
PROJECT NO. DPEZ 189031
COMBAT ARMS TRAINING
TOM SVOBODA
10221664
CIVIL
STRUCTURAL
ARCHITECTURAL
ELECTRICAL
MECHANICAL
FIRE PROTECTION
COMMUNICATIONS
AND EMERGENCY
MANAGEMENT FACILITY
T. MATTSON
J. LENZ
S. HEANEY
J. ZAVADIL
J. LEWIS
A. NOWKA
K. JEYEONG
GENERAL CIVIL LEGEND
G004
NTS G004
AutoCAD SHX Text
12"ST
AutoCAD SHX Text 12"W
AutoCAD SHX Text
POLYETHYLENE PIPE
AutoCAD SHX Text
PE
AutoCAD SHX Text
EXISTING STORM SEWER & SIZE
AutoCAD SHX Text
EXISTING WATER MAIN & SIZE
AutoCAD SHX Text
REINFORCED CONCRETE PIPE
AutoCAD SHX Text
CURED IN PLACE PIPE
AutoCAD SHX Text
CIPP
AutoCAD SHX Text
CAST IRON PIPE
AutoCAD SHX Text
CIP
AutoCAD SHX Text
RCP
AutoCAD SHX Text
DUCTILE IRON PIPE
AutoCAD SHX Text
DIP
AutoCAD SHX Text
SOLID WALL POLYVINYL CHLORIDE PIPE
AutoCAD SHX Text
PVC
AutoCAD SHX Text
VITRIFIED CLAY PIPE
AutoCAD SHX Text
%%UABBREVIATIONS
AutoCAD SHX Text
VCP
AutoCAD SHX Text
PROPOSED WYE
AutoCAD SHX Text Y
AutoCAD SHX Text
PROPOSED M.J. PLUG
AutoCAD SHX Text
PROPOSED S.J. PLUG
AutoCAD SHX Text
PROPOSED 11 1/4%%D BEND
AutoCAD SHX Text
PROPOSED 22 1/2%%D BEND
AutoCAD SHX Text
MJP
AutoCAD SHX Text
SJP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING TEE
AutoCAD SHX Text T
AutoCAD SHX Text
EXISTING SIDEWALK
AutoCAD SHX Text
EXISTING DROP INLET
AutoCAD SHX Text
EXISTING APPROACH
AutoCAD SHX Text
EXISTING STORM MANHOLE/ JUNCTION BOX
AutoCAD SHX Text
PROPOSED 45%%D BEND
AutoCAD SHX Text
PROPOSED 90%%D BEND
AutoCAD SHX Text
PROPOSED FIRE HYDRANT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text
PROPOSED SLEEVE
AutoCAD SHX Text
PROPOSED REDUCER OR INCREASER
AutoCAD SHX Text
PROPOSED CROSS
AutoCAD SHX Text
PROPOSED TEE
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text X
AutoCAD SHX Text
EXISTING SPRINKLER HEAD
AutoCAD SHX Text
EXISTING WATER MANHOLE
AutoCAD SHX Text
EXISTING CROSS
AutoCAD SHX Text
EXISTING SLEEVE
AutoCAD SHX Text
EXISTING REDUCER
AutoCAD SHX Text
PROPOSED VALVE & BOX
AutoCAD SHX Text V
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
EXISTING VALVE & BOX
AutoCAD SHX Text
EXISTING FIRE HYDRANT
AutoCAD SHX Text
EXISTING HEDGE, BRUSH, SHRUBS, WOODS
AutoCAD SHX Text
EXISTING CONIFEROUS TREE & SIZE
AutoCAD SHX Text
EXISTING DECIDUOUS TREE & SIZE
AutoCAD SHX Text
EXISTING GAS METER
AutoCAD SHX Text
EXISTING SIGN
AutoCAD SHX Text
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text
WV
AutoCAD SHX Text W
AutoCAD SHX Text
EXISTING SANITARY MANHOLE
AutoCAD SHX Text S
AutoCAD SHX Text
ST
AutoCAD SHX Text
EXISTING TELEPHONE MANHOLE/ JUNCTION BOX
AutoCAD SHX Text T
AutoCAD SHX Text
EXISTING TELEPHONE PEDESTAL
AutoCAD SHX Text
EXISTING TRAFFIC MANHOLE/ JUNCTION BOX
AutoCAD SHX Text
TR
AutoCAD SHX Text
HIGH DENSITY POLYETHYLENE PIPE
AutoCAD SHX Text
HDPE
AutoCAD SHX Text
EXISTING ELECTRIC MANHOLE/ JUNCTION BOX
AutoCAD SHX Text P
AutoCAD SHX Text
FIBERGLASS REINFORCED
AutoCAD SHX Text
FRPM
AutoCAD SHX Text 12"S
AutoCAD SHX Text
EXISTING SANITARY SEWER & SIZE
AutoCAD SHX Text
12"FM
AutoCAD SHX Text
EXISTING FORCE MAIN & SIZE
AutoCAD SHX Text G
AutoCAD SHX Text
EXISTING GAS LINE
AutoCAD SHX Text
EXISTING UNDERGROUND TELEPHONE
AutoCAD SHX Text
EXISTING FIBER OPTIC
AutoCAD SHX Text
EXISTING CABLE TELEVISION
AutoCAD SHX Text
EXISTING UNDERGROUND ELECTRIC
AutoCAD SHX Text T
AutoCAD SHX Text
FO
AutoCAD SHX Text
CTV
AutoCAD SHX Text
UE
AutoCAD SHX Text
EXISTING OVERHEAD ELECTRIC
AutoCAD SHX Text
EXISTING TRAFFIC
AutoCAD SHX Text
OHE
AutoCAD SHX Text
TR
AutoCAD SHX Text
EXISTING DRAIN TILE LINE AND SIZE
AutoCAD SHX Text
EXISTING WOVEN WIRE FENCE
AutoCAD SHX Text
EXISTING ELECTRIC FENCE
AutoCAD SHX Text
4"DT
AutoCAD SHX Text
EXISTING BARBED WIRE FENCE
AutoCAD SHX Text
EXISTING DRINKING FOUNTAIN
AutoCAD SHX Text
EXISTING WATER SHUTOFF
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text
EXISTING ELECTRIC PEDESTAL/ TRANSFORMER
AutoCAD SHX Text
EXISTING CENTERLINE
AutoCAD SHX Text
EXISTING PROPERTY LINE
AutoCAD SHX Text
EXISTING EASEMENT
AutoCAD SHX Text
EXISTING PROPERTY CORNER MONUMENT
AutoCAD SHX Text B
AutoCAD SHX Text
EXISTING HORIZONTAL CONTROL
AutoCAD SHX Text
EXISTING VERTICAL CONTROL
AutoCAD SHX Text
EXISTING TREE STUMP
AutoCAD SHX Text
MB
AutoCAD SHX Text S
AutoCAD SHX Text
PROPOSED SANITARY MANHOLE
AutoCAD SHX Text
EXISTING TRAFFIC SIGNAL LIGHT
AutoCAD SHX Text
EXISTING POWER POLE
AutoCAD SHX Text
EXISTING MAILBOX
AutoCAD SHX Text
EXISTING GUY WIRE ANCHOR
AutoCAD SHX Text
SUE-1
AutoCAD SHX Text
AutoCAD SHX Text
SB-1
AutoCAD SHX Text
BOTTOM SOIL BORING ELEVATION
AutoCAD SHX Text
REFUSAL SOIL BORING ELEVATION
AutoCAD SHX Text
WATER LINE SOIL BORING ELEVATION
AutoCAD SHX Text
SOIL BORING, EXISTING GROUND ELEVATION, AND NUMBER
AutoCAD SHX Text
SUB-UTILITY EXPLORATION AND UTILITY ELEVATION
AutoCAD SHX Text
DIRECTION OF FLOW
AutoCAD SHX Text
PROPOSED CATCH BASIN
AutoCAD SHX Text
PROPOSED STORM SEWER DROP INLET
AutoCAD SHX Text
PROPOSED STORM SEWER INTAKE
AutoCAD SHX Text
PROPOSED STORM SEWER FLARED END
AutoCAD SHX Text
PROPOSED LIFT STATION
AutoCAD SHX Text
PROPOSED TRENCHED SANITARY SEWER
AutoCAD SHX Text
PROPOSED WATER MAIN
AutoCAD SHX Text
PROPOSED STORM SEWER
AutoCAD SHX Text
PROPOSED FIBER OPTIC
AutoCAD SHX Text
PROPOSED ACC
AutoCAD SHX Text
PROPOSED CLEAN OUT
AutoCAD SHX Text
PROPOSED STORM SEWER JUNCTION BOX
AutoCAD SHX Text
PROPOSED RIP RAP
AutoCAD SHX Text
SP
AutoCAD SHX Text
/WP
AutoCAD SHX Text
EXISTING STEEL POST/ WOOD POST
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
2" NPW
AutoCAD SHX Text
NON POTABLE WATER & SIZE
AutoCAD SHX Text
EXISTING STREET LIGHT/TRAIL LIGHT
AutoCAD SHX Text
GW
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING CONTOURS
AutoCAD SHX Text
FO
AutoCAD SHX Text
PROPOSED FIBER OPTIC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED SANITARY CAP/PLUG
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
POLYMER MORTAR PIPE
AutoCAD SHX Text
MECHANICAL JOINT
AutoCAD SHX Text
MJ
AutoCAD SHX Text
8"WLS
AutoCAD SHX Text
WATER LINE SLUDGE
AutoCAD SHX Text
CO
AutoCAD SHX Text
PROPOSED PCC
AutoCAD SHX Text
TO BE REMOVED OR ABANDONED
AutoCAD SHX Text
TEXT
AutoCAD SHX Text
REMOVE ACC PAVING
AutoCAD SHX Text
REMOVE PCC PAVEMENT
AutoCAD SHX Text
PROPOSED CONTOURS
AutoCAD SHX Text
CONSTRUCTION LIMITS
AutoCAD SHX Text G004
THODGE
Stamp
HDR PROJECT NUMBER
0 1" 2"
SCALE
FILENAME
CIVIL
STRUCTURAL
ARCHITECTURAL
ELECTRICAL
MECHANICAL
FIRE PROTECTION
COMMUNICATIONS
ISSUE DATE DESCRIPTION
NONE
1 2 3 4 5 6 7 8
D
C
B
SHEET
T. MATTSON
J. LENZ
S. HEANEY
J. ZAVADIL
J. LEWIS
A. NOWKA
K. JEYEONG
B
IM
/1
C H
J V
W
Y C
A T
M E
M D e s ig n
/1
C
A T
M -E
M -S
A F
.r v t
/2
/2
:1
:5
P M
G005 10221664
TOM SVOBODA
10221664_CATM-EM-SAF.rte
CODE ANALYSISWYOMING ANG
PROJECT NO. DPEZ 189031
COMBAT ARMS TRAINING
AND EMERGENCY
MANAGEMENT FACILITY
DEFINITION
• ACTUAL BUILDING HEIGHT AND STORIES: 25 FT 0 IN AND ONE (1) STORY IBC § 502 BUILDING HEIGHT
• ALLOWABLE HEIGHT: 75 FT AND 3 STORIES FOR FULLY SPRINKLED GROUP B AND GROUP S-1 BUILDINGS IBC § 504.1 TABLE...
TOTAL 14,981 SF
CAT-EM 6,511 SF DEFINITION
• ACTUAL TOTAL BUILDING AREA: SFS 8,470 SF IBC § 502 BUILDING AREA
• ALLOWABLE AREA WITH FRONTAGE INCREASE: NONE TAKEN IBC § 506.2.4
FRONTAGE INCREASE : NONE TAKEN
• FRONTAGE INCREASE: NOT REQUIRED IBC § 506.3
AND GROUP S-1 WITH AUTOMATIC SPRINKLERS.)
• ALLOWABLE TABULATED FLOOR AREA: 70,000 SF (SINGLE STORY, MIXED USE; GROUP B IBC Table 506.2.2
• BUILDING IS FULLY PROTECTED WITH AUTOMATIC SPRINKLERS.
• TYPE IIB CONSTRUCTION (IBC) - (000) PER NFPA 220 IBC § 602 & TABLE 601
IBC CHAPTER 5 AND UFC 3-600-01 APPLY. UFC 1-200-01 § 2-5
AND STANDARDS
THE CODE COMPLIANT APPROACH HEREIN DESCRIBES THE REQUIREMENTS FOR THE BUILDING (SFS AND CAT-EM BUILDING) TO ACHIEVE CODE COMPLIANCE WITH CURRENT...
SFS BUILDING AND CAT-EM BUILDING (PROVIDED AS PART OF A SEPARATE CONTRACT) ARE BEING CONSIDERED ONE BUILDING FROM A BUILDING CODE PERSPECTIVE.
GENERAL BUILDING HEIGHTS AND AREAS:
STORAGE ORDINARY-HAZARD CONTENTS STORAGE NFPA 101 CHAPTER 42
NEW FACTORY ARMORY WEAPONS REPAIR & CLEANING NFPA 101 CHAPTER 40
NEW BUSINESS NFPA 101 CHAPTER 38
NEW ASSEMBLY (INCIDENTAL USE) NFPA 101 CHAPTER 12
• NFPA OCCUPANCY CLASSIFICATIONS - MIXED OCCUPANCIES: NFPA 101 § 6.1.14.3
FINISH, FIRE PROTECTION FEATURES AND MEANS OF EGRESS.
RATING OF INTERIOR LOAD-BEARING PARTITIONS (OTHER THAN OCCUPANCY SEPARATION), INTERIOR
NFPA 101 APPLIES TO OCCUPANCY CLASSIFICATION AS IT RELATES TO FIRE/SMOKE RESISTANCE UFC 3-600-01 § 3-3.1.2
GROUP S-1 MODERATE-HAZARD STORAGE IBC § 311 (STORAGE)
GROUP F-1 ARMORY WEAPONS MAINTENANCE & REPAIR IBC § 307 (FACTORY)
GROUP B BUSINESS IBC § 304 (BUSINESS)
GROUP A-3 ASSEMBLY (ACCESSORY USE ONLY , < 10% OF BUILDING AREA) IBC § 303 (ASSEMBLY)
• IBC OCCUPANCY CLASSIFICATIONS - MIXED USE AND OCCUPANCY - NON-SEPARATED OCCUPANCY: IBC § 508.3
AREA, BUILDING SEPARATION AND OCCUPANCY SEPARATION.
IBC APPLIES TO OCCUPANCY CLASSIFICATION AS IT RELATES TO BUILDING HEIGHT, BUILDING UFC 3-600-01 § 3-2.1.2
IBC CHAPTER 3 AND UFC 3-600-01 APPLY. UFC 1-200-01 § 2-3
USE AND OCCUPANCY CLASSIFICATION:
BUILIDNG CODE CORRESPONDING TO APPLICABLE OF IBC, PER UFC 1-200-01 APPLY.
ENGINEERING TECHNICAL LETTERS OVER-RULE AIR FORCE ENGINEERING TECHNICAL LETTERS AND NFPA STANDARDS. ONLY THE PORTIONS OF
UFC'S OVER-RULE ALL CRITERIA; AIR FORCE ENGINEERING TECHNICAL LETTERS OVER-RULE NFPA STANDARDS. AIR NATIONAL GUARD
WHERE DISCREPANCIES BETWEEN REGULATIONS AND TECHNICAL LETTERS OCCUR, THE FOLLOWING HIERARCHY WILL BE USED:
APPLICATION HIERARCHY
ASME/ANSI A13.1- SCHEME FOR THE IDENTIFICATION OF PIPING SYSTEMS.
ANGETL 15-01-05, ELECTRICAL AND COMMUNICATIONS ENGINEERING, 1 MAY 2015
ANGETL 15-01-03, FIRE PROTECTION DESIGN GUIDANCE, 1 MAY 2015
INSTALLATION DESIGN GUIDE - WYOMING AIR NATIONAL GUARD DESIGN MANUAL
ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS, 2015 EDITION
INTERNATIONAL CODE COUNCIL, INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION (AS AMENDED BY UFC 1-200-01)
OTHER REFERENCES
NFPA 1963 STANDARD FOR FIRE HOSE CONNECTIONS, 2019 EDITION
NFPA 704 STANDARD SYSTEM FOR THE IDENTIFICATION OF THE HAZARDS OF MATERIALS FOR EMERGENCY RESPONSE, 2017 EDITION
NFPA 291 RECOMMEND PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS, 2019 EDITION
NFPA 241 STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2019 EDITION
NFPA 221 STANDARD FOR HIGH CHALLENGE FIRE WALLS, FIRE WALLS, AND FIRE BARRIER WALLS, 2018 EDITION
NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION, 2018 EDITION
NFPA 170 STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS, 2018 EDITION
NFPA 101 LIFE SAFETY CODE, 2018 EDITION.
NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2019 EDITION
NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2019 EDITION
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2019 EDITION
NFPA 70 NATIONAL ELECTRIC CODE, 2020 EDITION
NFPA 51B STANDARD FOR FIRE PREVENTION DURING WELDING, CUTTING AND OTHER HOT WORK, 2019 EDITION
NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, 2019 EDITION
NFPA 13 STANDARD FOR THE INSTALLATION OF AUTOMATIC SPRINKLERS, 2019 EDITION
NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018 EDITION
NFPA 1 FIRE CODE, 2018 EDITION
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
UFC 4-021-01 DESIGN AND O&M MASS NOTIFICATION SYSTEMS, 9 APR 2008, CHANGE 1, JAN 2010
UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DEC 2018, CHANGE 1, 19 AUG 2020
UFC 3-601-02 OPERATION AND MAINTENANCE: INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS, 8 SEP 2010
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUG 2016, CHANGE 5, 12 AUG 2020
UFC 3-520-01 INTERIOR ELECTRICAL SYSTEMS, 26 OCT 2015
UFC 3-400-02 DESIGN: ENGINEERING WEATHER DATA, 20 SEP 2018
UFC 3-230-01 WATER STORAGE AND DISTRIBUTION, 1 SEP 2018, CHANGE 2, 1 MAY 2020
UFC 3-301-01 STRUCTURAL ENGINEERING, 1 OCT 2019.
UFC 1-300-02 UNIFIED FACILITIES GUIDE SPECIFICATIONS FORMAT STANDARD, 1 APR 2014, CHANGE 2, 1 APR 2019
UFC 1-200-01 DOD BUILDING CODE, 8 OCT 2019
UNIFIED FACILITIES CRITERIA (UFC)
REFERENCED CODES AND STANDARDS:
FIRE PROTECTION / LIFE SAFETY CODE ANALYSIS
WITH HYDRANTS SPACED AT 300 FT MAXIMUM.
• EXTERIOR STORAGE AND MILITARY/TACTICAL EQUIPMENT/VEHICLE PARKING MUST BE PROVIDED
• AT LEAST ONE HYDRANT MUST BE LOCATED WITHIN 150 FT OF THE FIRE DEPARTMENT CONNECTION. UFC 3-600-01 § 9-3.5.8.4
GIVEN TO ACCESSIBILITY AND OBSTRUCTIONS (INCLUDING FENCES).
• ALL PARTS OF THE FACILITY EXTERIOR MUST BE WITHIN 350 FT OF A HYDRANT WITH CONSIDERATION UFC 3-600-01 § 9-3.5.8.2
• HYDRANTS ADJACENT TO AIRFIELD PAVEMENT WILL COMPLY WITH UFC 3-260-01. UFC 3-600-01 § 9-3.5.7(H)
FROM HYDRANTS.
• BOLLARDS, FENCING, LANDSCAPING AND SIMILAR OBSTRUCTIONS WILL BE LOCATED AT LEAST 24 IN. UFC 3-600-01 § 9-3.5.7(G)
• HYDRANTS MUST BE INSTALLED ADJACENT TO PAVED AREAS, ACCESSIBLE TO FIRE DEPARTMENT APPARATUS. UFC 3-600-01 § 9-3.5.7(B)
• HYDRANTS WILL NOT BE LOCATED LESS THAN 40 FT. FROM BUILDINGS. NFPA 24 § 7.2.3
• POST INDICATOR VALVE WILL BE WALL PIV. NFPA 24 § 6.2.9 (2)
• POST INDICATOR VALVES WILL NOT BE LOCATED LESS THAN 40 FT. FROM BUILDINGS. NFPA 24 § 6.2.9
POST INDICATOR VALVE LOCATION & FIRE HYDRANT PLACEMENT AND COVERAGE (SEE CODE COMPLIANCE SITE PLAN)
OF FIRE FLOW OR SPRINKLER SYSTEM DEMAND.
• MINIMUM RESIDUAL PRESSURE IN A SERVICE LATERAL MUST NOT BE LESS THAN 20 PSI AT THE GREAT UFC 3-600-01 § 9-3.3.3
• MINIMUM SERVICE LATERAL FOR SPRINKLER SYSTEMS MUST NOT BE LESS THAN 6 IN. UFC 3-600-01 § 9-3.3.2
• NOT MORE THAN 2 HYDRANTS CAN BE LOCATED ON A SERVICE LATERAL. UFC 3-600-01 § 9-3.3.1
THE REQUIRED FIRE FLOW IN CASE OF A SINGLE BREAK.
• SERVICE MAINS MUST NOT BE DEAD-ENDED AND MUST BE LOOPED TO PROVIDE AT LEAST 50 PERCENT OF UFC 3-600-01 § 9-3.2.2-3
• SERVICE MAINS MUST BE SIZED TO CARRY FIRE FLOW AND DOMESTIC AND INDUSTRIAL DEMANDS. UFC 3-600-01 § 9-3.2.1
• SERVICE MAINS AND SERVICE LATERALS MUST COMPLY WITH AWWA M31, NFPA 24 AND UFC 3-230-01. UFC 3-600-01 § 9-3.1.1
SERVICE MAINS AND LATERALS
• MINIMUM FIRE FLOW OF 500 GPM AT 20 PSI FOR A 2 HR DURATION IS REQUIRED FOR VEHICLE PARKING AREAS.
UFC -600-01 § 9-2.2.51
• FIRE FLOW IS INDEPENDENT OF SPRINKLER SYSTEM DEMAND.
UFC -600-01 § 9-2.1
• FIRE FLOW FOR SPRINKLERED FACILITIES MUST BE A MINIMUM OF 1,000 GPM AT 20 PSI.
UFC -600-01 § 9-2.1
FIRE FLOW FOR FACILITIES
• ALL-WEATHER GROUND ACCESS WILL BE LOCATED WITHIN 150 FT OF FIRE DEPARTMENT CONNECTIONS.
UFC -600-01 § 9-1.4
• DIMENSIONS OF FIRE LANES AND TURNAROUNDS WILL COMPLY WITH NFPA 1.
UFC -600-01 § 9-1.3
FROM AN EXTERIOR DOOR ACCESSIBLE TO FIRE DEPARTMENT INGRESS.
• ALL-WEATHER PAVED ACCESS WILL START AT THE ROAD AND TERMINATE NO FARTHER THAN 33 FT
UFC -600-01 § 9-1.1
ACCESS TO THE FACILITY WILL BE PROVIDED.
• ONE MEANS OF PAVED ALL-WEATHER GROUND ACCESS TO ALLOW EMERGENCY VEHICLES UNIMPEDED
UFC -600-01 § 9-1.1
FIRE DEPARTMENT VEHICLE ACCESS (SEE CODE COMPLIANCE SITE PLAN)
USE UFC 3-600-01 IN LIEU OF IBC CHAPTER 9. UFC 1-200-01 § 2-9
FIRE PROTECTION SYSTEMS:
INDUSTRIAL A, B OR C A, B, OR C A, B, OR C CLASS I OR II
STORAGE A, B OR C A, B, OR C A, B, OR C CLASS I OR II
BUSINESS A, B OR C A, B, OR C A, B, OR C CLASS I OR II
ASSEMBLY A OR B A, B, OR C A, B, OR C CLASS I OR II
EXITS
EXIT ACCESS
CORRIDORS
ROOMS AND
ENCLOSED SPACES
INTERIOR FINISH
FLOOR
GROUP
WITH AUTOMATIC SPRINKLER SYSTEMS
INTERIOR WALL, CEILING, AND FLOOR FINISHES: NFPA 101 CHAPTER 10 TABLE A.10.2.2
CONFORM TO THE REQUIRMENTS OF NFPA 101 CHAPTER 10.
UFC 3-600-01 § 8-1
USE UFC 3-600-01 AND UFC 3-120-10 IN LIEU OF IBC CHAPTER 8. UFC 1-200-01 § 2-8
INTERIOR FINISHES:
DESIGNED AND TESTED IN ACCORDANCE WITH ANSI/UL 555 AND ANSI/UL555S WILL BE INSTALLED.
• WHERE A SMOKE BARRIER IS ALSO CONSTRUCTED AS A FIRE BARRIER, A COMBINATION FIRE/SMOKE DAMPER NFPA 101 § 8.5.5.2.2
DAMPER DESIGNED AND TESTED IN ACCORDANCE WITH ANSI/UL555S WILL BE INSTALLED.
• WHERE SMOKE BARRIERS ARE PENETRATED BY DUCT OR AIR TRANSFER OPENING, A SMOKE NFPA 101 § 8.5.5.2.1
FIRE AND SMOKE DAMPERS
SPRINKLER PROTECTION IS PROVIDED.
HAZARD GREATER THAN THAT NORMAL TO THE GENERAL OCCUPANCY WHERE AUTOMATIC 12.3.2.1.2 (b)
• A SMOKE PARTITON WILL BE PROVIDED TO SEPARATE AN AREA HAVING A DEGREE OF NFPA 101 § 8,7,1,2 (1), 38.3.2.1, PROTECTION FROM HAZARDS - APPLIES TO JANITORIAL CLOSETS (SEE LIFE SAFETY PLAN)
INCLUDING SUPPORTING COLUMNS WILL ALSO BE 1-HOUR FIRE RESISTANT RATED.
THE ENTIRE LENGTH AND SPAN OF SUPPORTING ELEMENTS FOR THE RATED ROOF ASSEMBLY
• THE ROOF ASSEMBLY WITHIN 10 FT OF THE WALL WILL HAVE A 1-HOUR FIRE RESISTANCE RATING. IBC § 706.6.1 AND NFPA 221 § 6.7 (2)
• THE FIRE BARRIER WILL BE CONSTRUCTED IN ACCORDANCE WITH NFPA 221. IBC § 706.2
• THE FIRE BARRIER WILL HAVE A FIRE RESISTANCE RATING OF 2 HOURS. IBC § 707.3.10
CONSTRUCTED AS A FIRE BARRIER MAY BE USED TO SEPARATE THE TWO BUILDINGS.
• WHERE THE FIRE SEPARATION DISTANCE BETWEEN TWO BUILDINGS IS LESS THAN 5 FT, A PARTY WALL IBC § 602 AND 707.3.10
FIRE BARRIER FOR SEPARATE FIRE AREAS (SEE LIFE SAFETY PLAN)
SPECIFICALLY REFERENCE IBC CHAPTER 7.
CONFORM TO THE REQUIRMENTS OF NFPA 101 CHAPTER 8, EXCEPT WHERE IBC CHAPTERS 5 AND 6
UFC 3-600-01 § 7-1
IBC CHAPTER 7 AND UFC 3-600-01 APPLY. UFC 1-200-01 § 2-7
FIRE AND SMOKE PROTECTION FEATURES:
NOTE 2: FIRE RATING MAYBE INCREASED DUE TO OTHER CRITERIA SUCH AS FIRE AREA SEPARATION.
NOTE 1: FIRE RATING INCREASED TO 2-HOUR FIRE BARRIER DUE TO ELECTRICAL SERVICE REQUIREMENT PER NEC.
• ROOF CONSTRUCTION (INCLUDING SUPPORTING BEAMS AND JOISTS): 0 HOUR
• FLOOR CONSTRUCTION (INCLUDING SUPPORTING BEAMS AND JOISTS): 0 HOUR
• NON-BEARING WALLS & PARTITIONS - INTERIOR: 0 HOUR (NOTE 1,2)
• NON-BEARING WALLS - EXTERIOR SEPARATION DISTANCE >30 FT: 0 HOUR
• BEARING WALLS - INTERIOR: 0 HOUR
• BEARING WALLS - EXTERIOR SEPARATION DISTANCE >30 FT: 0 HOUR
• STRUCTURAL FRAME (INCLUDING COLUMNS, GIRDERS, AND TRUSSES): 0 HOUR
IBC 601 & TABLE 602 ALL ALLOWABLE COMBUSTIBLE
MATERIALS AS DEFINED IN SECTION 603
REQUIRED STRUCTURAL ELEMENTS:
• TYPE IIB CONSTRUCTION (IBC) - (000) PER NFPA 220 IBC § 602 & TABLE 601
IBC CHAPTER 6 AND UFC 3-600-01 APPLY. UFC 1-200-01 § 2-6
TYPES OF CONSTRUCTION:
• EVERY EXIT OR DIRECTIONAL SIGN WILL BE ILLUMINATED BY A RELIABLE LIGHT SOURCE. NFPA 101 § 7.10.5.1
LOCATION WHERE DIRECTION OF TRAVEL TO REACH THE NEAREST EXIT IS NOT APPARENT.
• A SIGN WITH DIRECTIONAL INDICATOR SHOWING DIRECTION OF TRAVEL WILL BE PLACED IN EVERY NFPA 101 § 7.10.2.1
THE EXIT OR WAY TO REACH EXITIS NOT READILY APPARENT TO OCCUPANTS.
• ACCESS TO EXITS WILL BE MARKED BY APPROVED, READILY VISIBLE SIGNS IN ALL CASES WHERE NFPA 101 § 7.10.1.5.1
EXITS, WILL BE MARKED BY APPROVED SIGNS.
• EXITS OTHER THAN MAIN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIED AS NFPA 101 § 7.10.1.2.1
MARKING MEANS OF EGRESS
• MINIMUM ILLUMINATION FOR FLOORS AND OTHER WALKING SURFACES WILL BE AT LEAST 1 FC. NFPA 101 § 7.8.1.3 (2)
WALKING SURFACE).
• MINIMUM ILLUMINATION FOR MEANS OF EGRESS WILL BE AT LEAST 10 FC (MEASURED FROM NFPA 101 § 7.8.1.3 (1)
ILLUMINATION OF MEANS OF EGRESS
• SPECIAL PURPOSE INDUSTRIAL, (SPRINKLERED): 50 FT NFPA 101 § 40.2.5.1
• STORAGE, SPRINKLERED: 100 FT (ORDINARY-HAZARD CONTENTS) NFPA 101 § 42.2.5
• BUSINESS, SPRINKLERED: 50 FT NFPA 101 § 38.2.5.2.1
• ASSEMBLY, SPRINKLERED: 20 FT NFPA 101 § 12.2.5.1.3
DEAD-END LIMITS
• SPECIAL PURPOSE INDUSTRIAL, (SPRINKLERED): 100 FT NFPA 101 § 40.2.5.1
• STORAGE, SPRINKLERED: 100 FT, 75 FT SINGLE MEANS OF EGRESS (O-H CONTENTS) NFPA 101 § 42.2.5
• BUSINESS, SPRINKLERED: 100 FT NFPA 101 § 38.2.5.3.1
• ASSEMBLY, SPRINKLERED: < 50 OCCUPANTS 75 FT, > 75 OCCUPANTS 20 FT NFPA 101 § 12.2.5.1.2
COMMON PATH OF TRAVEL
• SPECIAL PURPOSE INDUSTRIAL, (SPRINKLERED): 400 FT NFPA 101 § 40.2.6.1
• STORAGE, (SPRINKLERED): 400 FT (ORDINARY-HAZARD CONTENTS) NFPA 101 § 42.2.6
• BUSINESS, (SPRINKLERED): 300 FT NFPA 101 § 38.2.6.3
• ASSEMBLY, (SPRINKLERED): 250 FT NFPA 101 § 12.2.6.2 (1)
TRAVEL DISTANCE TO AN EXIT
THAN 1/3RD THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED.
• MINIMUM DISTANCE SEPARATION BETWEEN EXITS AND EXIT ACCESS DOORS WILL BE NOT LESS NFPA 101 § 7.5.1.3.3
REMOTENESS OF EXITS
• IT EQUIPMENT ROOMS: 300 SQ FT/PERSON GROSS FLOOR AREA
• MECHANICAL/ELECTRICAL ROOMS: 500 SQ FT/PERSON GROSS FLOOR AREA UFC 3-600-01, TABLE 10-1
• SPECIAL PURPOSE INDUSTRIAL USE: 500 SQ FT/PERSON GROSS FLOOR AREA (STORAGE)
• STORAGE USE: 500 SQ FT/PERSON GROSS FLOOR AREA
• BUSINESS USE: 100 SQ FT/PERSON GROSS FLOOR AREA
• ASSEMBLY USE: LESS CONCENTRATED WITHOUT FIXED SEATING 15 SQ FT/PERSON NET AREA
NFPA 101 TABLE 7.3.1.2
OCCUPANCY LOAD FACTORS
OF THE REQUIRED EGRESS WIDTH.
• DOORS LEAVES SWINGING INTO THE THE MEANS OF EGRESS WILL LEAVE NOT LESS THAN ON HALF NFPA 101 § 7.2.1.4.3.1
DOOR LEAF ENCROACHMENT
• DOORS WILL SWING IN THE DIRECTION OF TRAVEL WHERE SERVING MORE THAN 50 PERSONS. NFPA 101 § 7.2.1.4.2 (1)
DOOR LEAF SWING DIRECTION
LIGHTING IN ACCORDANCE WITH NFPA 101 § 7.9.
• THE EGRESS SIDE OF ACCESS-CONTROLLED EGRESS DOORS WILL BE PROVIDED WITH EMERGENCY NFPA 101 § 7.2.1.6.2(7)
FIRE PROTECTIVE SIGNALLING SYSTEM IS MANUALLY RESET.
UNLOCK THE EGRESS DOORS IN THE DIRECTION OF EGRESS AND THEY WILL REMAIN UNLOCKED UNTIL THE
• ACTIVATION OF THE BUILDING SPRINKLER SYSTEM OR FIRE PROTECTION SIGNALING SYSTEM WILL NFPA 101 § 7.2.1.6.2(6)
THE LOCK, INDEPENDENT OF LOCKING SYSTEM ELECTRONICS.
• WHEN OPERATED, THE MANUAL RELEASE DEVICE WILL RESULT IN DIRECT INTERRUPTION OF POWER TO
READS "PUSH TO EXIT".
• THE MANUAL RELEASE DEVICE WILL BE READILY ACCESSIBLE AND CLEARLY IDENTIFIED BY A SIGN THAT
AND WITHIN 60 IN. OF THE SECURED DOOR OPENING.
• MANUAL RELEASE DEVICE WILL BE LOCATED ON THE EGRESS SIDE 40 IN TO 48 IN ABOVE THE FLOOR
DEVICE COMPLYING WITH THE FOLLOWING:
• DOOR LOCKS WILL BE ARRANGED TO UNLOCK IN THE DIRECTION OF EGRESS FROM A MANUAL RELEASE NFPA 101 § 7.2.1.6.2(3)
THE SENSOR OR TO THE PART OF THE SYSTEM THAT LOCKS THE DOOR.
• DOOR LEAVE WILL AUTOMATICALLY UNLOCK IN THE DIRECTION OF TRAVEL UPON LOSS OF POWER TO NFPA 101 § 7.2.1.6.2(2)
OF EGRESS UPON DETECTION OF APPROACHING OCCUPANT.
• SENSOR WILL BE PROVIDED ON THE EGRESS SIDE, ARRANGED TO UNLOCK THE DOOR IN THE DIRECTION NFPA 101 § 7.2.1.6.2(1)
LOCKING HARDWARE THAT PREVENTS EGRESS, PROVIDED THAT THE FOLLOWING ARE MET:
• DOOR ASSEMBLIES IN THE MEANS OF EGRESS WILL BE PERMITTED TO BE EQUIPPED WITH ELECTRICAL NFPA 101 § 7.2.1.6.2
ACCESS-CONTROLLED EGRESS DOOR ASSEMBLIES
CORRIDORS NEED NOT BE PROTECTED WITH FIRE RATED CONSTRUCTION. 38.3.6.1 (3), 42.3.6
• WHERE AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IS PROVIDED THROUGHOUT, NFPA 101 § 7.1.3.1 (2), 12.3.6 (2), NFPA 101 EXIT ACCESS CORRIDORS
OF THE 2018 IBC ARE ACCPETABLE.
• WHERE ABA STANDARDS REFERENCES PREVIOUS VERSIONS OF IBC, THE APPLICABLE REQUIRMENTS
ACT (ABA) STANDARDS.
• DO NOT USE IBC CHAPTER 10, EXCEPT WHERE REFERENCED BY ARCHITECTURAL BARRIERS
USE UFC 3-600-01 IN LIEU OF IBC CHAPTER 10. UFC 1-200-01 § 2-10
MEANS OF EGRESS (SEE LIFE SAFETY PLANS):
• KNOXBOX SHALL BE MONITORED BY FIRE ALARM SYSTEM AND FLUSH TYPE.
• SURGE PROTECTION DEVICE WILL BE PROVIDED FOR ALL 120 VAC POWERED FIRE ALARM AND MNS EQUIPMENT. UFC 3-600-01 § 9-18.11.2
• BREAKER LOCK WILL BE PROVIDED FOR FIRE ALARM AND MNS IAW UFC 3-520-01. UFC 3-600-01 § 9-18.11.1
• THE FIRE ALARM EVACUATION SIGNAL WILL BROADCAST OVER THE MNS SYSTEM. UFC 3-600-01 § 9-18.1.2.1
• VOICE INTELLIGIBILITY TO BE PROVIDED THROUGHOUT (CIS >0.8 OR STI > 0.70).
UFC 4-021-01 § 4-6.1.2
THAN 200 FT OR TRAVEL TO OTHER FLOORS TO ACCESS LOC.
• LOCAL OPERATOR CONSOLE (LOC) INSTALLED SO OCCUPANTS DO NOT NEED TO TRAVEL MORE UFC 4-021-01 § 4-5.1
• MASS NOTIFICATION SYSTEM PROVIDED WHERE OCCUPANT LOAD IS 11 OR MORE PERSONS. UFC 4-010-01 § B-4.6
• NOTIFICIATION TO BE PROVIDED THROUGHOUT ENTIRE BUILDING. UFC 3-600-01 § 9-18.6.1
• SPRINKLER VALVE SUPERVISION - SEPARATE ADDRESS FOR EACH VALVE. UFC 3-600-01 § 9-18.7.3
• SPRINKLER WATERFLOW MONITORING - SEPARATE ADDRESS FOR EACH WATERFLOW SWITCH. UFC 3-600-01 § 9-18.7.1
• MANUAL PULL STATION AT ALL EXIT DOORS. UFC 3-600-01 § 9-18.7.4
• DETECTOR COVERAGE AREA WILL BE REDUCED BY 50% WHERE HVLS FANS ARE USED. UFC 3-600-01 § 9-18.5.1.2
• REMOTE ANNUNCIATOR PROVIDED AT DESIGNATED FIRE DEPARTMENT ENTRANCE. UFC 3-600-01 § 9-18.4.4
AND 3) COMMAND POST BUILDING 36.
• MONACO D-21 REPORTING TO BASE RECEIVING STATIONS IN THE; 1) FIRE DEPARTMENT, 2) SECURITY BUILDING WY ANG IDG
• ANALOG / ADDRESSABLE FIRE ALARM SYSTEM WILL BE PROVIDED. UFC 3-600-01 § 9-18.4
• MASS NOTIFICIATION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH UFC 4-021-01. UFC 3-600-01 § 9-18.4
• FIRE ALARM SYSTEM TO BE INSTALL IN ACCORDANCE WITH UFC-3-600-01, NFPA 70, NFPA 72 AND ABA. UFC 3-600-01 § 9-18.3.1
• BUILDING TO BE INHABITED (ROUTINELY OCCUPIED BY 11 OR MORE 11 OCCUPANTS). UFC 4-011 § 1-8
• MASS NOTIFICIATION SYSTEM IS REQUIRED THROUGHOUT.
OR WITH MORE THAN 50 OCCUPANTS ABOVE OR BELOW LEVEL OF EXIT DISCHARGE.
• BUSINESS OCCUPANCY - FIRE ALARM REQUIRED FOR OCCUPANT LOAD > 300 PERSONS. NFPA 101 § 38.3.4.1
• ASSEMBLY OCCUPANCY - FIRE ALARM REQUIRED FOR OCCUPANT LOADS > 300 PERSONS. NFPA 101 § 12.3.4.1.1
• FIRE ALARM SYSTEM IS REQUIRED THROUGHOUT.
FIRE ALARM AND MASS NOTIFICATION SYSTEM (MNS)
• MECHANICAL ROOMS WILL HAVE BRACKET MOUNTED FIRE EXTINGUISHERS. UFC 3-600-01 § 9-17.3.2
• RECESSED OR SEMI-RECESSED CABINETS TO BE PROVIDED IN FINISHED SPACES. UFC 3-600-01 § 9-17.3.1
ELECTRONICS (EG: CLEAN AGENT).
• EXTINGUISHERS FOR ELECTRONIC EQUIPMENT AREAS SPACES WILL BE SUITABLE FOR UFC 3-600-01 § 9-17.2.2
• PORTABLE FIRE EXTINGUISHERS WILL BE LOCATED IN ACCORDANCE WITH NFPA 10. UFC 3-600-01 § 9-17.2.1
• GENERAL PURPOSE FIRE EXTINGUISHERS ARE REQUIRED FOR FULLY SPRINKLERED BUILDINGS, UFC 3-600-01 § 9-17.1
PORTABLE FIRE EXTINGUISHERS
• THE DISTANCE FROM EXTERIOR DOORS TO ANY PORTION OF THE BUILDING DOES NOT EXCEED 450 FT. UFC 3-600-01 § 9-10.2.2
• THE BUILDING DOES NOT EXCEED 4 STORIES. UFC 3-600-01 § 9-10.2.1
• STANDPIPE SYSTEMS IS NOT REQUIRED.
STANDPIPE SYSTEMS
HIGH TEMP SPRINKLER DENSITY = 0.25/2500 REDUCED (0.25 * 0.70) TO 0.175 / 2500 NFPA 13 - FIGURE 21.2.2.2 & 21.2.2.3
CEILING HEIGHT OF 17.0 FT BOTTOM OF DECK - 0.5 FT DEFLECTOR DISTANCE - 1.5 FT MINIMUM CLEAR TO STORAGE = 15.0 NFPA 13 - FIGURE 21.2.2.2 & 21.2.2.3
WITH NFPA 13 PER OF UFC 3-600-01 - 4-46.2.3.1 FOR CLASS IV NON-ENCAPSULATED STORAGE TO MAXIMUM AVAILABLE HEIGHT.
• WAREHOUSE HIGH PILED STORAGE AREAS WILL BE PROTECTED BY AUTOMATIC SPRINKLER SYSTEM DESIGN WILL BE IN... UFC 3-600-01 § 4-46.2.3.1
3-600-01 9-7.3
• AUTOMATIC SPRINKLER SYSTEM DESIGN WILL BE IN ACCORDANCE WITH TABLE 9-3 & TABLE 9-4 OF UFC UFC 3-600-01 § 9-7.3
MODIFIED BY UFC-3-600-01.
• AUTOMATIC SPRINKLER SYSTEMS MUST COMPLY WITH NFPA 13 EXCEPT WHERE SPECIFICALLY UFC 3-600-01 § 9-7.1.1
EXCEEDING 15,000 SQFT.
• AUTOMATIC SPRINKLER PROTECTION IS REQUIRED FOR SINGLE STORY TYPE I OR II CONSTRUCTION UFC 3-600-01 § 9-7.2.1.1
• AUTOMATIC SPRINKLER PROTECTION IS REQUIRED THROUGHOUT.
AUTOMATIC SPRINKLER PROTECTION
1/22/2021 ISSUED FOR BID
W
W
W
12''W
12''W
W
W
W
W
W
W
W
W
W
W
W
BUILDING
FRONTAGE
A
L
W
E
A
T
H
R
F
I
R
E
D
E
P
A
R
T
M
E
N
T
A
C
C
E
S
S
A
A
T
H
R
F
I
R
E
D
E
P
A
R
T
M
E
N
T
A
C
C
E
S
S
EXISTING FIRE
HYDRANT
WPIV
FIRE HOSE
DISTANCE 166 FT
FIRE HOSE
DISTANCE 156 FT
FIRE HOSE
DISTANCE 161 FT
FIRE HOSE
DISTANCE 172 FT
FIRE HYDRANT
DISTANCE TO FDC 35 FT
SFS BUILDING
CAT-EM
BUILDING
W
W
W
W
W
W
W
W
W
W
EXISTING
EXISTING FIRE
HYDRANT
EXISTING FIRE
HYDRANT
CODE COMPLIANCE SITE PLAN
G006
1"=40' G006
PROPOSED 8"
FIRE WATER
SERVICE AND
WPIV
FIRE HYDRANT
FIRE HOSE DISTANCE
SITE CODE COMPLIANCE SYMBOLS
W
UNDERGROUND WATER MAIN
FIRE DEPARTMENT CONNECTION (FDC)
WALL MOUNTED POST INDICATOR VALVE (WPIV)
WPIV
SITE CODE COMPLIANCE DISTANCES
FIRE HYDRANT TO FDC
FIRE HOSE COVERAGE
150 FEET
9-3.5.8.4
166 FEET
35 FEET
FIRE DEPARTMENT ACCESS NFPA 1 - 18.2.3.5.1.1
UFC 3-600-01
REQUIRED/ALLOWED
ACTUAL
20 FEET
350 FEET
20 FEET
9-3.5.8.2
SITE CODE COMPLIANCE REQUIREMENTS (UFC -3-600-01 1-7.2.4.2)
BUILDING CODE SUMMARY
BUILDING FRONTAGE / PERIMETER
IBC - 506.2.4
30 FEET & 7.5 FEET
0 FEET (NO FRONTAGE REQUIRED)
UFC 1-200-01 DOD BUILDING CODE, 8 OCT 2019
2018 IBC AS AMENDED BY UFC 1-200-01
2018 IEBC AS AMENDED BY UFC 3-600-01
2018 NFPA 101 LIFE SAFETY CODE
2018 NFPA 1 FIRE CODE
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES,
8 AUG 2016, CHANGE 5, 12 AUG 2020
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILENAME
SCALE
SHEET
DATE
C
D
A
1 3 4 5 6 7 8
WYOMING ANG
PROJECT NO. DPEZ 189031
COMBAT ARMS TRAINING
TOM SVOBODA
10221664
CIVIL
STRUCTURAL
ARCHITECTURAL
ELECTRICAL
MECHANICAL
FIRE PROTECTION
COMMUNICATIONS
AND EMERGENCY
MANAGEMENT FACILITY
T. MATTSON
J. LENZ
S. HEANEY
J. ZAVADIL
J. LEWIS
A. NOWKA
K. JEYEONG
1/22/2021 ISSUED FOR BID
C p w w o r k i n g c e n t r a l d
G d w g
G
P
M
T
H F
R E
E M
A
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text H
AutoCAD SHX Text Y
AutoCAD SHX Text D
AutoCAD SHX Text H
AutoCAD SHX Text Y
AutoCAD SHX Text D
AutoCAD SHX Text
WV
SP SP SP SP SP
CP-1 CP-1
C P
-1 C
P -1
TD-1 TD-1
T D
-1 T
D -1
TD-1 TD-1
T D
-1 T
D -1
T D
-1
C P
-2 C
P -2
C P
-2
CP-2 CP-2
D E
-1 D
E -1
T D
-2 T
D -2
T D
-2 T
D -2
T D
-2 T
D -2
T D
-2
T D
-2 T
D -2
SP SP SP SP
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
SP SP SP SP
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
SP SP SP SP SP SP SP SP SP SP SP SP
S P
S P
S P
S P
S P
S
P SP
S
P SP SP SP SP SP SP
SP SP SP SP SP SP SP
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
SP SP SP SP SP SP SP SP SP SP SP
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
S P
SP SP SP SP SP SP SP SP SP SP SP
S S
S S
SP SP SP SP SP SP SP SP SP
S P
S
PSP
S P
S P
S P
S P
EXIT SYMBOL
FIRE EXTINGUSHER
EXIT DOOR TAG
LIFE SAFETY NOTES:
1. FOR EXIT LIGHTS AND EMERGENCY LIGHTING, SEE ELECTRICAL
LIGHTING DRAWINGS (E SERIES).
2. SEE CODE ANALYSIS SHEET G005 FOR ALL REQUIREMENTS NOT
SPECIFICALLY INDICATED ON THIS SHEET.
LINE TYPES FOR MEANS OF EGRESS:
TRAVEL DISTANCE
COMMON PATH
SYMBOLCOMPONENT
LIFE SAFETY SYMBOLS:
TD
CP
EXIT DISCHARGE ARROW
EXIT DISCHARGE
A CLEAR DOOR WIDTH [FEET - INCHES]
B OCCUPANT LOAD CAPACITY [NO.OF PEOPLE]
DEAD END DE
WALL RATING LEGEND
SMOKE PARTITION
A
FLIGHT
COMMANDER
103 FLIGHT
CHIEF
SUPER
MECH
COMBAT
ARMS
TRAINING/
SIMULATOR
CATM
INSTRUCTORS
EM
CLASSROOM
RANGE
STORAGE
EM TECHS
EM
STORAGE
BREAK
COPY
ELEC
WEAPONS
MAINTENANCE
WEAPONS
CLEANING
WOMEN
MEN
CUSTODIAL
COMM
CLASSRM
STORAGE
CLASSRM
STORAGE
CORR
CATM
CLASSROOM
VEST
DOOR
2' - 8"
101 A
DOOR
2' - 8"
107 B
DOOR
2'…