This document is a Scope of Work for a wire mesh partition contract opportunity from the Capital Development Board (CDB) for the state of Illinois. The Scope outlines the requirements for heavy duty wire mesh partitions, including specifications for the materials, fabrication, hardware, and finishes. It also details the installation requirements, such as ensuring the partitions are plumb, level, and securely fastened. The contract opportunity is for an 8'x8' cage size partition system, with a 2" maximum sweep space under the panels and doors. The document includes submittal requirements for product data, shop drawings, color samples, and locking mechanism samples. It also specifies the keying requirements and quantities to be provided to the Using Agency at project completion.
The document does not provide specifics on pricing terms, set asides, incumbents, funding sources, or contract duration. It appears to be a technical Scope of Work for the wire mesh partition product and installation, without additional commercial or procurement details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bldg 5 Caging.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CDB #546-095-015 10 22 13 - 1 WIRE MESH PARTITIONS
DIVISION 10 - SPECIALTIES
Section 10 22 13 - WIRE MESH PARTITIONS
PART 1 GENERAL
1.1 WORK INCLUDES
General Contractor provide heavy duty wire mesh partitions as indicated on drawing sheets or specified herein.
1.2 QUALITY ASSURANCE
A. Design Requirements:
1. Design partition system to provide for movement of components without damage, undue stress on fasteners or other detrimental effects, when subject to design loads.
2. Design system to accommodate construction tolerances, deflection of building structural members, and clearances of intended openings.
1.3 REFERENCES
A. ASTM D3451-Standard Guide for Testing Coating Powders and Powder
Coatings.
1.4 PRODUCT DELIVERY, STORAGE AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
1.5 JOB CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
1.6 SUBMITTALS
A. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Detailed specification of construction and fabrication.
2. Manufacturer's installation instructions.
3. Preparation instructions and recommendations.
4. Storage and handling requirements and recommendations.
B. Shop Drawings: Indicate dimensions, description of materials and finishes, general construction, specific modifications, component connections, anchorage
CDB #546-095-015 10 22 13 - 2 WIRE MESH PARTITIONS
methods, hardware, and installation procedures, plus the following specific requirements.
1. Provide location template drawings for items supported or anchored to permanent construction.
C. Selection Samples: For each finish product specified, one complete set of color chips representing manufacturer's full range of available colors and patterns.
D. Sample of Locking Mechanism: Provide one complete cylindrical mortise type lock with recessed knob for Using Agency’s approval.
E. Keys: Keys and removable PRIMUS core/cylinders with blocking rings should be provided to Using Agency at Substantial Completion of the project. See section 08 71 00.
PART 2 PRODUCTS
2.1 MATERIALS
A. Product series #135, size group D, 8’x8’ cage size.
B. Fabrication:
1. 10 gauge (.135 in) steel wire, woven into 1 1/2" diamond mesh, with wire securely clinched to framing.
2. Wire shall be woven through a horizontal 1" x 1/2" x 12 gauge channel bar at 3'6 1/8" from bottom of partition.
3. Vertical frames 1 1/4" x 5/8" C-type, cold rolled channel. Horizontal frames 1" x 1/2" x 12 gauge channel, mortised and tenoned at intersections.
4. Top capping bar 2 1/2" x 3/4"cold rolled channel with 1/4" U-bolts approximately 18" oc.
5. Corner post 1 1/4" x 1 1/4" x 1/8" angle.
6. Slide door frames 1 1/2" x 3/4" x 12 gauge channel. Hinged door frames 1
1/4" x 1/2" x 12 gauge channel with 1 1/4" x 1/8" cover plate on four sides.
7. Sliding doors to have: Two 4-wheel ball bearing trucks hung in enclosed box track, slide door strike keeper, bottom guide channel.
8. Hinged doors to have: 1 1/2" pair fast pin butts, continuous 1 3/8" x 7/8" x
1/8" angle strike.
9. 2" maximum sweep space under all panels and doors, and between panels and roof deck/structural roof framing.
10. Cylinder Lock: Mortise type interchangeable core cylinder operated by key outside and recessed, tamper resistant turn knob inside.
Interchangeable core cylinders shall accept Schlage Interchangeable Primus Cores. See Section 08 71 00.2.3 for keying requirements and key quantities.
11. All hardware necessary for proper installation to be furnished. Hardware shall be tamper proof.
CDB #546-095-015 10 22 13 - 3 WIRE MESH PARTITIONS
12. Finish: Color as selected by Using Agency from standard available powder coat colors.
13. 2" x 2" x 14 gauge tubing posts between all panels as required for framing heights.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verification of Conditions: Examine areas and conditions under which Work is to be performed and identify conditions detrimental to proper or timely completion.
1. Do not proceed until unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Comply with manufacturer's recommendations.
B. Install partitions and gates plumb and level, accurately fitted, properly aligned, securely fastened, and free from distortion or detects.
C. Install field bracing as necessary to provide rigid, secure installation.
3.3 TOLERANCES
A. Maximum Variation from Plumb or Level: 1/4 inch (6 mm) in total partition height.
B. Maximum Misalignment from True Position: 1/4 inch (6 mm).
3.4 ADJUSTING
A. Adjust moving components for smooth operation without binding.
B. Adjust locks to provide smooth and secure operation.
3.5 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before Substantial Completion.
END OF SECTION