I{)

1·-0· 10"

2x6 RAFTERS

J � 1·-0· o

1•-4• 1•-4•

1•-4• 1•-4• t -N H

.---..rn---------.'--3_/_8_- R-.S--,.�

I

LYWO��

, \ I 1,....-., �

II

I ':,t-

2x4 FRAME

WITH 3/4"

DEEP DADO

FOR PLYWOOD

1 r ifRANSLUCENT 'LEXAN'

PANELS, SEE SHT. A4

GRAB BAR, 33"

ABOVE FIN. FLR.

lfov�

�1i:

R

�Lr

ELONGATED, OPEN

FRONT SEAT WITH

COVER ------..,��

L

I 2x4 STUDS

DOOR

TOILET RISER

18"

ABOVE FIN. rLR.

, STOP

PRIVACY SCREEN,

3/8" R.S. PLYWOOD

ON INSIDE,

CHANNEL 5/4" x 8"

R.S. REDWOOD

BEVEL SIDING ON

A1 1/2"=1'-0"

OUTSIDE

t O

'GLASBORD' WALL PAN.::..----:

OVER 1/2" PLYWOOD

nrruo 111c, 5 ::5 Pl IS• 1-1/4" DIA. X 42" GRAB

BAR 33" ABOVE FIN. FLR.

TOILET RISER

DOOR STOP (TYP.)

U.S. DEPARTMENT OF AGRICULTURE

Forest

FOREST SERVICE

FIBERGLASS SHINGLES ON

30/1 ROOFING FELT

3/4" PLYWOOD SHEATHING

,_ �RAKE FLASHING

--1x8 FASCIA �5/4" x 8" R.S. REDWOOD

/II

BtvEL SIDING t 1 /2" PLYWOOD SEAL AROUND

II VENT STACK

-END WALL TRUSSES TO HAVE

VERTICAL 2x4 WEB MEMBERS

I

AT 16" O.C.

DOUBLE 2x4 TOP PLATE r TRANSLUCENT 'LEXAN' PANEL

1-1/2" RIGID FOAM INSULATION

12" DIA. METAL

I .

VENT STACK (PAINTED)

1 ir •w1NDow· UNIT

1 ~ �����c�'&s i � STONE VENEER

-� 2x4 STUDS

� ANCHOR BOLT

'--"'l· .... ----t .... , \ \_ REDWOOD 4x4 PLATE

\_ 1-1/2" WIDE FLANGE WELDED TO

VENf STACK. SET IN ADHESIVE

WHEN BLDG. IS SET IN PLACE

GENERAL NOTE

VAULT DE TAILS HAVE BEEN

OMITTED FOR CLARITY. SEE

SHEET A5 FOR VAULT

DETAILS.

ASPHALT LAMINATE FIBERGLASS

SHINGLES ON 30/1 ROOFING FELT

TRUSSED RAFTERS

WITH PLYWOOD

GUSSETS, SEE

SHEET A3

5/4" x 8" R.S.

REDWOOD BEVEL SIDING

B A1

,,,-12" DIA. SHEET

/ METAL VENT

SECTION

1/2"=1·-o·

STACK

4" WIDE SHEET METAL

UNION WELDED TO LOWER

VENT SECTION

'SIMPSON H3' FRAMING ANCHOR,

ONE PER TRUSS (USE 'SIMPSON

A33' WHERE TRUSSES ATTACH

---�6 TO 4x6 BEAMS)

·. 2x6 . · BLOCKING

1 x8 REDWOOD FASCIA

8" R.S. PLYWOOD

OFFIT

SEAL TOP OF VENT CHASE

l WITH 1/2" PLYWOOD r---_ 1-1/2" RIGID

INSULATION

�-1:::=-2x6 BLOCKING FOR GRAB

BARS & T.P. HOLDER, TYP.

STONE VENEER

REDWOOD 4x4 SILL

1-1/2" x 1-1/2" FLANGE

WELDED TO VENT STACK SET

FLANGE IN ADHESIVE WHEN

BLDG. IS SET IN PLACE

12" DIA. SHEET

METAL VENT

STACK

ASPHALT LAMINATE

FIBERGLASS SHINGLES

ON /130 ROOFING

'b I i,,J

,,,,,,,,,- 12" DIA. SHEET METAL

/ VENT STACK

FLASHING 1 "x8" REDWOOD

FASCIA

J

.tiQIE_

1"xa·

REDWOOD

FASCIA

FELT

2"x4"

REDWOOD

FRAME

FOR BUILDING ORIENTATION,

SEE SITE PLAN

ARAPAHO/ ROOSEVELT

NATIONAL FORESTS

D A1

Design: ARAP /ROOS N.F.

Drawn: ARAP /ROOS N.F.

Checked: T. WONG

SADDLE

1/ 2"•4" lRIM

---- 5/4" x 8" R.S.

REDWOOD BEVEL it-----i SIDING

1" WASHED

GRAVEL PLACED

UNDER DRIP LINE

OF BOTH EAVES

TO BE 24" WIDE

6" DEEP .-+-1----=-\

,!ls

><r v

-:I (TYPICAL)

E FRONT ELEVATION

A1 3/8"=1'-0"

SIDE ELEVATION

3/8"=1·-o·

HALF SIZE DRAWINGS

SCALES SHOWN ARE FOR FULL

SIZE (22"x34") DRAWINGS

FLOOR PLAN BUILDING

SECTIONS AND ELEVATIONS

0 2 4

SCALE OF FEET

0 2

SCALE OF INCHES

Sub Sheet:

A1

6"x8" RS

REDWOOD

/ REDWOOD 6"x6" r POSTS

3/B" = 1'-o·

1;2· = 1'-o·

Project No:

AR-312

Sheet R-2

ROCKY MOUNTAIN REGION SULPHUR RANGER DISTRICT

Date:

WILLOW CREEK CAMPGROUND

03/2001 33 OF 61

General Note Replace fiberglass shingles with Asphalt shingles and replace metal vent stack with HDPE per specifications

General Note Replace fiberglass shingles with Asphalt shingles and replace metal vent stack with HDPE per specifications

General Note Replace fiberglass shingles with Asphalt shingles and replace metal vent stack with HDPE per specifications

To Contracting Old 2 - Cop.pdf
Location Map PLOT (1).pdf
Site Map PLOT (1).pdf
Existing Conditions Revised PLOT (1).pdf
A1-COMFSTA A1 (1).pdf
A2-COMFSTA-WALL-ELEV A2 (1).pdf
A3-COMFSTA-TRUSS A3 (1).pdf
A4-COMFSTA-DETS A4 (1).pdf
A5-COMFSTA-VAULT-DETS A5 (1).pdf
A6-MISC-DETS A6 (1).pdf

File details come from the government source that posted it. Updated .