WCS - 2022 Bond - BP T2 Technology Renovation to Support Construction Drawings_Bids.pdf
PDF 2 MB Posted
- Solicitation number
- RFP - WCS - 240000000538
- Issued by
- Macomb County, Warren City, Michigan
About this file
The provided document is for a technology renovation project for the Warren Consolidated Schools (WCS) 2022 Bond Program in Macomb County, Michigan. The project, titled "Technology Renovations to Support Construction Activities Bid Package No. T2", involves the disconnection, removal, and reinstallation of various technology equipment such as interactive displays, speakers, security cameras, and network devices across multiple school facilities. The work is to be completed in phases, with 100% Owner Review on 11/14/2023 and bids due on 11/30/2023.
The document includes detailed drawings and specifications outlining the scope of work for the technology renovations, including floor plans, demolition plans, and connection diagrams. It also provides general notes and requirements for the technology contractor, such as coordination with construction trades, cabling specifications, and installation methods. Pricing terms, funding sources, and other commercial details are not included in the provided document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Issue DateList of Drawings Code Information
Registration Seal
Date
Signature
Issued for
Date
Signature
Date
Signature c 2023 , LLCI N TEG ETRA D SOLU T SNIO i D s architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
Warren Consolidated Schools
2022 Bond Program Technology Renovations to Support Construction Activities
Bid Package No. T2 Warren, MI
22177-1000 BPT2
Autodesk Docs://Warren Consolidated Schools/Technology Details (2023).rvt
11/28/2023 2:07:40 PM
CVR
2.TR.0
2.T3.1A 2.T3.1B 2.T3.1C 2.T3.2A 2.T3.2B 2.T3.3C 2.T3.3A 2.T3.4A 2.T3.4B 2.T3.4C 2.T3.5A 2.T3.5B 2.T3.5C 2.T3.5D 2.T3.5E 2.T3.5F 2.T3.5G 2.T3.5H 2.T3.5I 2.T5.1 2.T7.1 2.T7.2
COVER
TECHNOLOGY REFERENCE INFORMATION
GREEN ACRES TECHNOLOGY PLAN - AREA A
GREEN ACRES TECHNOLOGY PLAN - AREA B
GREEN ACRES TECHNOLOGY PLAN - AREA C
HARWOOD TECHNOLOGY PLAN - AREA A
HARWOOD TECHNOLOGY PLAN - AREA B
HARWOOD TECHNOLOGY PLAN - AREA C
SIERSMA TECHNOLOGY PLAN - COMPOSITE FLOOR PLAN
PEARL O. LEAN TECHNOLOGY PLAN - AREA A
PEARL O. LEAN TECHNOLOGY PLAN - AREA B
PEARL O. LEAN TECHNOLOGY PLAN - AREA C
MOTT TECHNOLOGY PLAN - AREA A
MOTT TECHNOLOGY PLAN - AREA B
MOTT TECHNOLOGY PLAN - AREA C
MOTT TECHNOLOGY PLAN - AREA D
MOTT TECHNOLOGY PLAN - AREA E
MOTT TECHNOLOGY PLAN - AREA F
MOTT TECHNOLOGY PLAN - AREA G
MOTT TECHNOLOGY PLAN - AREA H
MOTT TECHNOLOGY PLAN - AREA I
AV FUNCTIONAL DIAGRAMS
DETAILS
FACEPLATE DETAILS
100% Owner Review 11/14/2023
Bids 11/30/2023
IN
T
E R
C O
M C
A
LL
B U
T T
O N
1.
2.
MOUNTING HEIGHT NOTES:
MOUNTING HEIGHTS ARE TYPICAL UNLESS OTHERWISE
NOTED ON DRAWINGS.
FOR CEILING HEIGHTS BELOW 8'-4" REFER TO DRAWINGS
FOR CLOCKS, SPEAKERS, EXIT LIGHTS AND EGRESS
LIGHTS MOUNTING HEIGHTS.
SYMBOLS
SYMBOL LEGEND MOUNTING HEIGHTS
DETAIL SYMBOL
DETAIL SCALE
DETAIL
PLAN OR DETAIL ENLARGEMENT
SECTION LOCATOR
DETAIL IDENTIFICATION
T2.1
T9.1
SECTION IDENTIFICATION
DRAWING WHERE DETAIL
IS REFERENCED OR CUT
PLAN OR DETAIL
IDENTIFICATION
DRAWING
WHERE PLAN OR
DETAILS IS DRAWN
DRAWING WHERE PLAN OR
DETAIL IS DRAWN
T9.1
ROOM NAME AND NUMBER
ROOM
FLOOR
BUILDING OR UNIT (IF ANY)
ROOM NAME
A101
COLUMN CENTERLINE
NEW
EXISTING
C O
M M
U N
IC
A
T
IO
N S
O U
T
LE
T M
O U
N T
E D
A B
O V
E C
O U
N T
E R
C O
M M
U N
IC
A
T
IO
N S
O U
T
LE
T M
O U
N T
E D
A B
O V
E C
O U
N T
E R
D U
P
LE
X R
E C
E P
T A
C
LE
A B
O V
E C
O U
N T
E R
D U
P
LE
X R
E C
E P
T A
C
LE
A B
O V
E C
O U
N T
E R
K E
Y S
W
IT
C H
S P
E A
K E
R S
C
LO
C K
S
V O
LU
M
E C
O N
T R
O L
C A
R D
A C
C E
S S
S Y
S T
E M
C A
R D
R E
A D
E R
A F
F
A F
F
7'
'8
A F
F
4'
A F
F
S
V S
CR
S K
A F
F
A F
F
C O
M M
U N
IC
A
T
IO
N S
O U
T
LE
T
T E
LE
V
IS
IO
N O
U T
LE
T
F O
R T
V M
O N
IT
O
R
W A
LL
M
O U
N T
E D
Q U
A D
R E
C E
P T
A C
LE
O
U T
LE
T
F O
R T
V M
O N
IT
O
R
R E
C E
P T
A C
LE
O
U T
LE
T
M
IC
R O
P H
O N
E O
U T
LE
T
7'
A F
F
1'
A F
FM
TVTV
A
ELEVATION NUMBER
DRAWING WHERE
ELEVATION IS DRAWN
ELEVATION SYMBOL
13 T9.1
I
THIS PROJECT MAY NOT UTILIZE ALL THE SYMBOLS,
MATERIALS, ABBREVIATIONS AND STANDARDS INFORMATION
SHOWN ON THIS SHEET
(LETTERS (X) INDICATE TYPE, TYPICAL)
T O
B O
T T
O M
C X
POWER
GFI
SS
SS
IG
SS SS
CD
X
PT
SINGLE RECEPTACLE OUTLET
DUPLEX RECEPTACLE OUTLET
DUPLEX RECEPTACLE OUTLET FLUSH MOUNTED IN CEILING
FLUSH MOUNTED POWER ONLY FLOOR BOX
DUPLEX RECEPTACLE OUTLET MOUNTED ABOVE COUNTER
J
J
GFI
E
I
IP
X
X
DUPLEX RECEPTACLE OUTLET WITH INTEGRAL GROUND
FAULT PROTECTION
DUPLEX RECEPTACLE OUTLET WITH INTEGRAL SURGE
SUPPRESSION
DUPLEX RECEPTACLE OUTLET CONNECTED TO
UPSTREAM SURGE SUPPRESSION DEVICE
DUPLEX RECEPTACLE OUTLET SPLIT WIRED
DUPLEX RECEPTACLE OUTLET WITH ISOLATED GROUND
QUAD RECEPTACLE OUTLET
QUAD RECEPTACLE OUTLET MOUNTED ABOVE COUNTER
QUAD RECEPTACLE OUTLET WITH ONE (1) INTEGRAL
SURGE SUPPRESSION TYPE RECEPTACLE AND ONE (1)
SURGE SUPPRESSION PROTECTED RECEPTACLE
SPECIAL RECEPTACLE AS INDICATED
POWER/COMMUNICATIONS POLE
SPECIAL POWER CONNECTION
CORD DROP
POKE THROUGH ASSEMBLY
LETTERS INDICATE TYPE (TYP)
JUNCTION BOX - CEILING MOUNTED
JUNCTION BOX - WALL MOUNTED
HORIZONTALLY MOUNTED MULTI-OUTLET RACEWAY
VERTICALLY MOUNTED MULTI-OUTLET RACEWAY
208/120V PANELBOARD
480/277V PANELBOARD
DISTRIBUTION OR POWER PANELBOARD
BUS DUCT
EQUIPMENT MOUNTING BACKBOARD
DUPLEX RECEPTACLE OUTLET CONNECTED TO
UPSTREAM GROUND FAULT PROTECTION DEVICE
PUSHBUTTON STATION - EMERGENCY POWER SHUTDOWN
INTERCOM CALL BUTTON
INTERCOM CALL BUTTON WITH PRIVACY
SINGLE PHASE MOTOR
THREE PHASE MOTOR
MAGNETIC MOTOR STARTER
30/30A
30A
30/30A
30ACB
M
H
T
G
S
S
DIG
S
S
S
M
M
V
C
H
B
COMBINATION WALL MOUNTED SPEAKER/CLOCK
AUXILIARY
COMBINATION MAGNETIC MOTOR STARTER
- SWITCH SIZE / FUSE SIZE
NON-FUSED DISCONNECT SWITCH
-SWITCH SIZE
FUSED DISCONNECT SWITCH
-SWITCH SIZE/FUSE SIZE
ENCLOSED CIRCUIT BREAKER
-CB RATING
MAGNETIC CONTACTOR
MANUAL MOTOR STARTER
PACKAGED EQUIPMENT WITH INTEGRALLY
MOUNTED PREWIRED CONTROL PANEL
TRANSFORMER
GROUND ROD
LIGHTNING PROTECTION AIR TERMINAL
CEILING MOUNTED SINGLE FACED CLOCK
CEILING MOUNTED DOUBLE FACED CLOCK
WALL MOUNTED SINGLE FACED CLOCK
WALL MOUNTED DOUBLE FACED CLOCK
CEILING MOUNTED COMBINATION SPEAKER/CLOCK
CEILING MOUNTED SPEAKER
HORSEPOWER RATED SWITCH
FURNISHED AS INTEGRAL PART OF EQUIPMENT
GROUND BUS BAR AS INDICATED
WALL MOUNTED DIGITAL CLOCK
CEILING MOUNTED SPEAKER CLUSTER
WALL MOUNTED SPEAKER
CEILING MOUNTED MICROPHONE OUTLET
WALL MOUNTED MICROPHONE OUTLET
WALL MOUNTED VOLUME CONTROL
WALL MOUNTED BELL
WALL MOUNTED CHIME
WALL MOUNTED HORN SPEAKER
MD
S CR
S C
S K
S
FACP
C
C
FSCP
FAAP
N
N 2B
N
BB
N
BC
CB
CEILING MOUNTED SECURITY CAMERA
-ARROWS INDICATE FIELD OF VIEW
FIRE ALARM CONTROL PANEL
FIRE SUPRESSION SYSTEM CONTROL PANEL
FIRE ALARM REMOTE ANNUNCIATOR PANEL
SINGLE BED STATION - NURSE CALL
DOUBLE BED STATION - NURSE CALL
BATHROOM STATION - NURSE CALL
BATHROOM STATION PULL CORD - NURSE CALL
CODE BLUE PUSHBUTTON - NURSE CALL
SECURITY SYSTEM ELECTRIC LATCH
SECURITY SYSTEM CARD READER
SECURITY SYSTEM DOOR CONTACT
SECURITY SYSTEM KEY SWITCH
SECURITY SYSTEM MOTION DETECTOR
WALL MOUNTED SECURITY CAMERA
-ARROWS INDICATE FIELD OF VIEW
N
DS
N E
N
MS
N
PS
N
SS
C
C
X
X
C/X
X
X
ONE-LINE
ABOVE COUNTER COMMUNICATIONS OUTLET
-LETTER INDICATES FACEPLATE TYPE
CEILING MOUNTED COMMUNICATIONS OUTLET
-LETTER INDICATES FACEPLATE TYPE
COMMUNICATIONS FLOORBOX
-LETTER INDICATES FACEPLATE TYPE
NURSE CALL DUTY STATION
NURSE CALL EMERGENCY STATION
NURSE CALL MASTER STATION
NURSE CALL POWER SUPPLY
NURSE CALL STAFF STATION
WALL MOUNTED COMMUNICATIONS OUTLET
-LETTER INDICATES FACEPLATE TYPE
NURSE CALL WALL MOUNTED DOME LIGHT
NURSE CALL CEILING MOUNTED DOME LIGHT
NURSE CALL WALL MOUNTED DOME LIGHT WITH CODE BLUE
NURSE CALL CEILING MOUNTED DOME LIGHT WITH CODE BLUE
MULTI-SYSTEM FLOORBOX
-LETTER INDICATES FACEPLATE TYPE
EXOTHERMIC WELD OR BRAZED CONNECTION
SYSTEM OR EQUIPMENT GROUND
CONDUIT IN OR BELOW FLOOR SLAB OR BELOW GRADE
RACEWAY TURNED UP
RACEWAY TURNED DOWN
CABLE TRAY
P
HP
C
HC
UNDERFLOOR DUCT - POWER
UNDERFLOOR HEADER DUCT - POWER
UNDERFLOOR DUCT - COMM
UNDERFLOOR HEADER DUCT - COMM
X
X
X
X
X
SITE
HH FLUSH IN-GRADE HAND HOLE
X
E
C
FO
L
UNDERGROUND ELECTRICAL
UNDERGOUND COMMUNICATIONS
UNDERGROUND FIBER OPTIC
COMMUNICATIONS
UNDERGROUND LIGHTING
S
S
BIDIRECTIONAL WALL MOUNTED SPEAKER
BIDIRECTIONAL CEILING MOUNTED SPEAKER
S
S
H CEILING MOUNTED HORN SPEAKER
S EL
WALL MOUNTED PROJETION SYSTEM
CEILING MOUNTED PROJETION SYSTEM
SHORT THROW PROJETION SYSTEM
CLASSROOM CONTROL PANEL (CCP)
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/T ec hn ol og y
D et ai ls rv t
/2
8/
:0 7:
P
M
S. Tyburski
T. Carron
L. Napoli
2.TR.0
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
No Scale
Technology Reference Information
1. LIGHT LINE WEIGHT INDICATES EXISTING EQUIPMENT TO REMAIN OR
EQUIPMENT PROVIDED BY OTHERS. HEAVY LINE WEIGHT INDICATES
NEW EQUIPMENT. SLASH MARKS INDICATE EQUIPMENT TO BE REMOVED
AND DISPOSED OF LAWFULLY OFFSITE. THE LETTER (R) REPRESENTS
EQUIPMENT TO BE RELOCATED.
2. NETWORK DEVICE PLATES AND THE CABLING FOR THESE PLATES SHALL
BE PROVIDED BY THE TECHNOLOGY CONTRACTOR.
3. TECHNOLOGY CONTRACTOR SHALL COORDINATE DEVICE OUTLET
LOCATIONS WITH THE EXISTING FIELD CONDITIONS PRIOR TO ROUGH-
IN. REPORT ANY CONFLICTS TO THE CONSTRUCTION MANAGER FOR
RESOLUTION.
4. TECHNOLOGY CONTRACTOR SHALL NOT PLACE ANY DISTRIBUTION
CABLING ALONGSIDE POWERLINES, OR SHARE THE SAME CONDUIT,
CHANNEL OR SLEEVE WITH ELECTRICAL APPARATUS.
5. ALL CABLES SHALL BE INSTALLED IN "J" HOOKS, CONDUITS, CABLE TRAY
OR AN APPROVED RACEWAY SYSTEM. WHERE CABLE TRAY IS NOT
AVAILABLE, SUPPORT HORIZONTAL CABLE EVERY FIVE FEET WITH "J"
HOOKS SUFFICIENT IN SIZE TO HANDLE ALL BUNDLED CABLES WHILE
MINIMIZING CRUSHING. IF CABLE SLACK EXCEEDS TWELVE (12) INCHES
BETWEEN SUPPORTS, ADDITIONAL SUPPORTS SHALL BE INSTALLED TO
TAKE UP SLACK AND RELIEVE CABLE STRESS. ALL CABLES SHALL BE
RUN PARALLEL AND PERPENDICULAR TO BUILDING STEEL. ALL
COMMUNICATIONS CABLES SHALL BE LOCATED AND FASTENED TO
GUARANTEE THERE SHALL BE NO INTERFERENCE FROM MAGNETIC
FIELDS GENERATED FROM FIXTURE BALLASTS, MOTORS OR SIMILAR
ELECTRICAL LOADS.
6. INSTALL ALL CABLES MAINTAINING CABLE MANUFACTURES RADIUS OF
CURVATURE AND PROTECT AT BENDS AND CORNERS. MAINTAIN
MINIMUM BEND RADUIS AND TENSION LIMITATIONS AS SPECIFIED BY
EIA/TIA FOR ALL COMMUNICATION CABLES.
7. LOOSELY BUNDLE CABLES WITH VELCRO TIES SUITABLE FOR PLENUM
ENVIRONMENTS, EVERY TWENTY FEET.
8. THE TECHNOLOGY CONTRACTOR SHALL ASSURE THAT THE
COMPLETION OF CABLE INSTALLATION. CABLES ARE FREE FROM
TWISTS, KINKS, SHARP BENDS, CUTS, GOUGES OR ANY OTHER
PHYSICAL DAMAGE.
9. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL
EXTENT OF WORK. THE TECHNOLOGY CONTRACTOR SHALL PROVIDE
ALL INCIDENTAL MATERIALS AND LABOR OR A COMPLETE, FULLY
FUNCTIONAL SYSTEM AND VERIFING FIELD RACEWAYS.
10. NOTIFY TECHNOLOGY DESIGNER OF ANY CONFLICTS BETWEEN
EQUIPMENT SUBMITTALS AND TECHNOLOGY DRAWINGS.
11. ALL WORK AND EQUIPMENT SHALL CONFORM TO NEC. THE MEANS AND
METHODS USED BY TECHNOLOGY CONTRACTOR SHALL CONFORM TO
NEC SECTION 110-3 (A, B, AND C).
GENERAL NOTES
KW KILOWATT
FT FOOT/FEET KVM KEYBOARD / VIDEO / MOUSE OS OCCUPANCY SENSOR WP WEATHER PROOF
FLR FLOOR KVA KILOVOLT AMPERE OFE OWNER FURNISHED EQUIPMENT WLAN WIRELESS LOCAL AREA NETWORK
CT CABLE TRAY FIB FIBER OPTIC KHZ KILOHERTZ OFCI OWNER FURNISHED, CONTRACTOR... WG WIRE GUARD
CP CONTROL PANEL FB FLOOR BOX K KILOHERTZ OC ON CENTER WB WHITEBOARD
CPU CENTRAL PROCESSING UNIT FACP FIRE ALARM CONTROL PANEL WAP WIRELESS ACCESS POINT
COMP COMPUTER FAAP FIRE ALARM ANNUNCIATING PANEL K O WAN WIDE AREA NETWORK
CLG CEILING FA FIRE ALARM
CKT CIRCUIT JC JANITORS CLOSET NTS NOT TO SCALE SW SWITCH W
CHBD CHALKBOARD F JB JUNCTION BOX NO NORMALLY OPEN STD STANDARD
CCTV CLOSED CIRCUIT TELEVISION NIC NOT-IN-CONTRACT SS SURGE SUPPRESSION VOIP VOICE OVER INTERNATE PROTOCOL
CCP CLASSROOM CONTROL PANEL EXIST EXISTING J NC NORMALLY CLOSED SPKR SPEAKER VIF VERIFY IN FIELD
CB CIRCUIT BREAKER ET ETHERNET SPECS SPECIFICATIONS VCR VIDEO CASSETTE RECORDER
CATV CABLE TELEVISION EQUIP EQUIPMENT IR INFRARED N SF SQUARE FEET VC VOLUME CONTROL
CAB CABINET EPT ELECTRIC POWER TRANSDUCER IP INTERNET PROTOCAL SD SMOKE DETECTOR V VOICE
EMT ELECTRIC METALLIC TUBING IN INCHES MTG MOUNTING SCRN PROJECTOR SCREENC EM EMERGENCY I/O INPUT / OUTPUT MTD MOUNTED V
ELEV ELEVATOR IG ISOLATED GRAND MON MONITOR S
BTU BRITISH THERMAL UNITS ELEC ELECTRICAL IDF INTERMEDIATE DISTRIBUTION FRAME MOD MODULATOR USB UNIVERSAL SERIAL BUS
BSMT BASEMENT EC ELECTRICAL CONTRACTOR MISC MISCELLANEOUS RX RECEIVER UPS UNINTERRUPTIBAL POWER SUPPLY
BOT BOTTOM EA EACH I MIN MINIMUM RGS RIGID GALVANIZED STEEL UON UNLESS OTHERWISE NOTED
BE BUILDING ENTRANCE MIC MICROPHONE RF RADIO FREQUENCY UL UNDERWRITERS LABORATORIES, INC.
BLDG BUILDING E HW HARD WIRED MH MOUNTING HEIGHT REQD REQUIRED
HVAC HEATING, VENTILATION AND AIR CONDITIONING MECH MECHANICAL R RELOCATE OR RELOCATED ITEM U
B DWG DRAWING HTR HEATER MDF MAIN DISTRIBUTION FRAME
AUD AUDIO DVD DIGITAL VERSATILE DISCT HRN HORN MC MASTER CLOCK R TYP TYPICAL
AWG AMERICAN WIRE GAUGE DP DISTTRIBUTION PANEL HP HORSEPOWER MAX MAXIMUM TX TRANSMITTER
AV AUDIO/VISUAL DN DOWN HH HAND HOLE PVC POLYVINYL CHLORIDE TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR % PERCENT, PERCENTAGE
ATS AUTOMATIC TRANSFER SWITCH DMARC DMARCATION POINT HD HIGH DEFINITION TV M PTZ PAN / TILT / ZOOM TV TELEVISION PH PHASE
ARCH ARCHITECT, ARCHITECTURAL DIA DIAMETER PT POKE THROUGH TTC TELEPHONE TERMINAL CABINET # NUMBER
ANT ANTENNA DHE DISTRICT HEADEND H LTG LIGHTING PROJ PROJECTOR TTB TELEPHONE TERMINAL BACKBOARD " INCH, INCHES
ALT ALTERNATE DEPT DEPARTMENT LP LIGHTING PANEL POS POINT OF SALE TR TAMPER RESISTANT ' FOOT, FEET
ALS ASSISTED LISTENING SYSTEM DEMOD DEMODULATOR GYP BD GYPSUM BOARD LED LIGHT EMMITTING DIODE PNL PANEL TKBD TACKBOARD ° DEGREES
AHU AIR HANDLING UNIT DEMO DEMOLISH, DEMOLITION GRD GROUND LCP LIGHTING CONTROL PANEL PIR PASSIVE INFRARED TERM TERMINAL ℄ OR C CENTERLINE
AFF ABOVE FINISH FLOOR DC DIRECT CURRENT GFCI GROUND FAULT CIRCUITINTERRUPTER LCD LIQUID CRYSTAL DISPLAY PH PHASE TELECOM TELECOMMUNICATIONS X BY
AC ALTERNATING CURRENT DA DIGITALLY ADDRESSABLE GFI GROUND FAULT INTERRUPTER LAR LINE ARRAY SPEAKER PB PULLBOX TEL TELEPHONE 4X NEMA 4X
A AMPERES D DATA GA GAGE/GAUGE LAN LOCAL AREA NETWORK PA PUBLIC ADDRESS TC TIME CLOCK 3R NEMA 3R
A D G L P T MISC
ABBREVIATIONS
B2 B-1
B-3B-4B-5B-6B-7
B
B-8
B-9 B-10
C-4C-1
C-3C-2
KITCHEN
MEDIA CENTER COMPUTERS
OFFICE
HEAD
END
PASSAGE
CLASSROOM
CLASSROOMCLASSROOM
CORRIDOR
CLASSROOM
CORRIDOR
CLASSROOMCLASSROOM
JAN.
TOILET
G
IR
L S
B O
Y S
CONF.CLASSROOM
CLASSROOM CORRIDOR CLASSROOM
B O
Y S
G
IR
L S
CORR
CORR CLASSROOMCLASSROOM
CLASSROOMCLASSROOM CONF.
U.V.
U.V.
U.V.
U.V. U.V. U.V. U.V.
U.V.
U.V.
KEY NOTES
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.2
22177-1000
BPT2
design design©
A
B C
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S G re en
A cr es E le m
-E
.r vt
/2
8/
:1 2:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T3.1A
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
4655 Holmes Dr.
Warren, MI 48092
Green Acres Technology Plan - Area A
MATCH LINE
2.T3.1A
2.T3.1B
MATCH LINE
2.T3.1A
2.T3.1B
1 DISCONNECT AND REMOVE 75" INTERACTIVE LCD DISPLAY AND
ASSOCIATED WALL BRACKETS. STORE DISPLAY AND MOUNT IN A SECURE
LOCATION WITHIN THE BUILDING (COORDINATE EXACT LOCATION WITH
OWNER). COIL AND LABEL CABLING AT CEILING TO PROTECT. REINSTALL
EQUIPMENT AND CABLING COMPLETE WHEN GENERAL CONSTRUCTION IS
COMPLETE.
C114 C115
B2 B-1
GYMNASIUM
VESTIBULE
OFFICE
TOILET
ROOM
TOILET
ROOM
CORR. CORR.
CLASSROOM
WORK
ROOM
TOILET
STOR
CAFETERIA
TOILET
PLATFORM
TOILETWORK
ROOM
WORK
ROOM
JAN.
KITCHEN
CORRIDOR TOILET
CLOSET
DRY
STOR. RECEIVING BOILER
ROOM
EQUIP OFFICE
ELEC
CORRIDOR
ELEC
TOILET
OFFICE
PRINCIPAL
CONF
CLINIC
CLASSROOM
TOILET
VEST.
OFFICE
HEAD
END
PASSAGE
CORR.
B O
Y S
G
IR
L S
OFFICE
U.V.
U.V.
U.V. U.V.
F E
C
EWC
T
.B
M .B
T
.B
M
.B
M .B
DISCONNECT AND REMOVE CEILING MOUNTED TECHNOLOGY EQUIPMENT
(SPEAKERS, WIRELESS ACCESS POINTS, SECURITY CAMERAS, ETC.) IN THIS
AREA FOR THE DURATION OF CONSTRUCTION. COIL AND LABEL CABLING IN
TRUSS SPACE TO PROTECT. COORDINATE EXTENT OF CEILING REMOVAL
WITH CONSTRUCTION TRADES. REINSTALL EQUIPMENT WHEN GENERAL
CONSTRUCTION IS COMPLETE. AIM ANY SECURITY CAMERAS TO OWNER'S
SATISFACTION.
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.2
22177-1000
BPT2
design design©
A
B C
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S G re en
A cr es E le m
-E
.r vt
/2
8/
:1 2:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T3.1B
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
4655 Holmes Dr.
Warren, MI 48092
Green Acres Technology Plan - Area B
MATCH LINE
2.T3.1A
2.T3.1B
MATCH LINE
2.T3.1A
2.T3.1B
MATCH LINE
2.T3.1B
2.T3.1C
M A
T C
H L
IN
E
2.
T
3.
1C
2.
T
.1
B
A-1
A-3A-5A-7
A-11
A113
A116
A118
A-10 A-8 A-6 A-4 A-2
B2 B-1
WORK
ROOM
TOILET
STOR
TOILET
PLATFORM
TOILETWORK
ROOM
WORK
ROOM
JAN.
CLOSET
CORRIDOR
ELEC
TOILET
OFFICE
PRINCIPAL
CONF
CLINIC
LOUNGE
CLASSROOMCLASSROOMCLASSROOM
CORRIDORCLASSROOM
CLOSET
VEST
TOILET
TOILET
CUSTODIANCLOSET
CLASSROOM CONF. CLASSROOM
TOILET
CLASSROOM
TOILET
TOILETTOILET TOILET CORRIDOR
TOILET
CLASSROOM CLASSROOM
TOILET
TOILET
VEST.
MEDIA CENTER COMPUTERS
OFFICE
HEAD
END
PASSAGE
CLASSROOM
CORR.
B O
Y S
G
IR
L S
U.V.
U.V.
U.V. U.V. U.V.
U.V.
U.V.U.V.U.V.U.V.
M .B
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.2
22177-1000
BPT2
design design©
A
B C
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S G re en
A cr es E le m
-E
.r vt
/2
8/
:1 2:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T3.1C
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
4655 Holmes Dr.
Warren, MI 48092
Green Acres Technology Plan - Area C
MATCH LINE
2.T3.1A
2.T3.1B
MATCH LINE
2.T3.1A
2.T3.1B
MATCH LINE
2.T3.1B
2.T3.1C
M A
T C
H L
IN
E
2.
T
3.
1C
2.
T
.1
B
MATCH LINE
2.T3.2A
2.T3.2B
MATCH LINE
2.T3.2A
2.T3.2B
2.T7.1
2,3
2.T7.1
2,3
2.T7.1 2,32.T7.1 2,32.T7.12,3
CLASSROOM
R4
CLASSROOM
R3
CLASSROOM
R5
CLASSROOM
R6
CLASSROOM
R7
CLASSROOM
R8
CLASSROOM
R9
CLASSROOM
R10
CLASSROOM
R11
CLASSROOM
R12
CLASSROOM
R13
CLASSROOM
R1
CLASSROOM
R2
MEDIA CENTER
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S H om er
H ar w oo d E le m
-E
.r vt
/2
8/
:1 4:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T3.2A
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
4900 Southlawn Dr.
Sterling Heights, MI 48310
Harwood Technology Plan - Area A
C B
A
Bids 1/30/2023111
2.T3.2B
2.T3.2C
MATCH LINE
2.T3.2C
2.T3.2B
MATCH LINE
2.T3.2A
2.T3.2B
MATCH LINE
2.T3.2A
2.T3.2B
2.T7.1
2,3
MUSIC STAGE
CLASSROOM
P1
CLASSROOM
P2
CLASSROOM
P3
CLASSROOM
P4
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S H om er
H ar w oo d E le m
-E
.r vt
/2
8/
:1 4:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T3.2B
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
4900 Southlawn Dr.
Sterling Heights, MI 48310
Harwood Technology Plan - Area B
C B
A
2.T3.2B
2.T3.2C
MATCH LINE
2.T3.2C
2.T3.2B
2.T7.1 2,32.T7.12,32.T7.1 2,32.T7.12,3
2.T7.1 2,32.T7.12,32.T7.1 2,32.T7.12,3
CLASSROOM
P12
CLASSROOM
P10
CLASSROOM
P8
CLASSROOM
P6
CLASSROOM
P5
CLASSROOM
P7
CLASSROOM
P9
CLASSROOM
P11
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S H om er
H ar w oo d E le m
-E
.r vt
/2
8/
:1 4:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T3.2C
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
4900 Southlawn Dr.
Sterling Heights, MI 48310
Harwood Technology Plan - Area C
C B
A
25'-6" 11'-6"
8'-0"
7'-4"
KEY NOTES
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S J oh n
H . S ie rs m a
E le m -E
.r vt
/2 8/
:1
9:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.3
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/16"=1'-0"
3100 Donna Ave.
Warren, MI 48091
Siersma Technology Plan - Composite Floor
Plan
DISCONNECT AND REMOVE ALL WALL MOUNTED EXTERIOR SECURITY
CAMERAS LOCATED ON METAL SIDING ALONG THE FULL EXTERIOR
PERMITER OF THE BUILDING. METAL SIDING IS BEING REPLACED BY
OTHERS. COIL AND PROTECT CABLING FOR THE DURATION OF
CONSTRUCTION. COORIDNATE REPLACEMENT BACKBOX LOCATIONS WITH
METAL SIDING CONTRACTOR AND ELEC TRADES IN FIELD (BACKBOXES BY
ELEC TRADES). REINSTALL SECURITY CAMERAS WHEN GENERAL
CONSTRUCTION IS COMPLETE. AIM CAMERAS TO OWNER'S SATISFACTION.
KEY NOTES
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S J oh n
H . S ie rs m a
E le m -E
.r vt
/2 8/
:1
9:
P M
S. Tyburski
T. Carron
Author
2.T3.3A
Designer
M. Nowicki
S. Tyburski
Warren Consolidated Schools
3100 Donna Ave.
Warren, MI 48091
Siersma Technology Plan - Area A
MATCH LINE
2.T3.3A
2.T3.3B
MATCH LINE
2.T3.3B
2.T3.3A
1 DISCONNECT AND REMOVE WALL MOUNTED SECURITY CAMERA FOR THE
DURATION OF CONSTRUCTION. COIL AND PROTECT CABLING FOR THE
DURATION OF CONSTRUCTION. REINSTALL SECURITY CAMERA WHEN
GENERAL CONSTRUCTION IS COMPLETE. AIM TO OWNER'S SATISFACTION.
7'-4"
KEY NOTES
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S J oh n
H . S ie rs m a
E le m -E
.r vt
/2 8/
:1
9:
P M
S. Tyburski
T. Carron
Author
2.T3.3B
Designer
M. Nowicki
S. Tyburski
Warren Consolidated Schools
3100 Donna Ave.
Warren, MI 48091
Siersma Technology Plan - Area B
MATCH LINE
2.T3.3C
2.T3.3B
MATCH LINE
2.T3.3B
2.T3.3C
1 DISCONNECT AND REMOVE WALL MOUNTED SECURITY CAMERA FOR THE
DURATION OF CONSTRUCTION. COIL AND PROTECT CABLING FOR THE
DURATION OF CONSTRUCTION. REINSTALL SECURITY CAMERA WHEN
GENERAL CONSTRUCTION IS COMPLETE. AIM TO OWNER'S SATISFACTION.
MATCH LINE
2.T3.3A
2.T3.3B
MATCH LINE
2.T3.3B
2.T3.3A
Bids 11/30/2023100% Owner Review 11/14/2023
25'-6" 11'-6"
8'-0"
KEY NOTES
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S J oh n
H . S ie rs m a
E le m -E
.r vt
/2 8/
:1
9:
P M
S. Tyburski
T. Carron
Author
2.T3.3C
Designer
M. Nowicki
S. Tyburski
Warren Consolidated Schools
3100 Donna Ave.
Warren, MI 48091
Siersma Technology Plan - Area C
MATCH LINE
2.T3.3C
2.T3.3B
MATCH LINE
2.T3.3B
2.T3.3C
1 DISCONNECT AND REMOVE CEILING MOUNTED TECHNOLOGY EQUIPMENT
(SPEAKERS, WIRELESS ACCESS POINTS, IR SENSORS, ETC.) IN THIS AREA
FOR THE DURATION OF CONSTRUCTION. COIL AND LABEL CABLING IN TRUSS
SPACE TO PROTECT. COORDINATE EXTENT OF CEILING REMOVAL WITH
CONSTRUCTION TRADES. REINSTALL EQUIPMENT WHEN GENERAL
CONSTRUCTION IS COMPLETE.
Bids 11/30/2023100% Owner Review 11/14/2023
A104
A103
A109
A102
A110
A113
A114
A115
A116
A121
A101
A124
A123
A122
A117
A119
A120
A100
A106 A107
A108
A111
A118
A125
A126
A127
A128
STORAGE
PLATFORM
DRAMA
CLASSROOM
BAND ROOM/
SEATING
OFFICE
PRACTICE
PRACTICE
PRACTICE
ELECTRICAL
INSTRUMENTS
VESTIBULE
OFFICE
CHOIR
CLASSROOM
UNIFORMS
STORAGE
WOMENS
MENS
LOBBY
RAMP STAIR
STAIR
CORR.
J.C.
OFFICE
OFFICE
STORAGE
HVAC
CLASSROOM
CLASSROOM
OFFICE
OFFICE
INSTRUMENTS
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5A
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area A
MATCH LINE
2.T3.5B
2.T3.5A
MATCH LINE
2.T3.5B
2.T3.5A
A
B
C
I
DF
G
H
E
MAT HOIST ABOVE
O.S.
O.S.
O.S.
D.S.
WARREN MOTT
MARAUDERS
W A
R R
E N
M O
T T
M A
R A
U D
E R
S
DISCONNECT AND REMOVE CEILING MOUNTED TECHNOLOGY EQUIPMENT (SPEAKERS, WIRELESS
ACCESS POINTS, SECURITY CAMERAS, ETC.) IN THIS AREA FOR THE DURATION OF CONSTRUCTION.
COIL AND LABEL CABLING IN TRUSS SPACE TO PROTECT. COORDINATE EXTENT OF CEILING
REMOVAL WITH CONSTRUCTION TRADES. REINSTALL EQUIPMENT IN NEW OWNER PROVIDED
CEILING TILES WHEN GENERAL CONSTRUCTION IS COMPLETE. AIM ANY SECURITY CAMERAS TO
OWNER'S SATISFACTION.
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5B
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area B
MATCH LINE
2.T3.5B
2.T3.5A
MATCH LINE
2.T3.5C
2.T3.5B
M A
T C
H L
IN
E
2.
T
3.
5C
2.
T
.5
B
MATCH LINE
2.T3.5B
2.T3.5A
A
B
C
I
DF
G
H
E
C125C123
C130
C128
E113
E112
E111
E108E107 E106
E126
E133
C105
C109
C103
C113
C104
C118
E145
E144
E143
E142
D155
D152
E127 E129
E128
F119
C102
C110
C115
C116
C119
E117 C121
E137
E109 E110
E115
E116
E134
E135
E136
E138
E140
E141
E146
E131
E132
C106
C107 C111
C112
C114
C117
C122
C120
C126
C127
C129
C131
C132
C133
D148
D149 D150
D154
D153
F121
C138
D156
D157
D158
C139
C137
C138
OFFICE
TRAINING
ROOM
BOYS GYM
LOCKER ROOM
COACH
OFFICE
OFFICE
OFFICE
ATHLETIC
CLASSROOMCLASSROOMCLASSROOM
SERVING
KITCHEN
STORAGE
OFFICE
WRESTLING
ROOM
GIRLS TEAM
LOCKER ROOM
STORAGE
OFFICE
STORAGE
BOYS
GIRLS
J.C.
STORAGE
STORAGE
HEAD
CUSTODIAN
BREAK RM.
STOR.
STORAGE
STORAGE
BOYS TEAM
LOCKER ROOM
GIRL'S
SHOWER
COACH'S
SHOWER
CORRIDOR
VEST.
CORRIDOR
DRY
STORAGE
TOILET TOILET
CORRIDOR
CORRIDOR
LOCKERS
TOILET
OFFICE
J.C.
CORR.
STAIR
STAIR
WALK-IN
FREEZER
WALK-IN
REFR.
CORR.
CORR.
BOY'S
TOILET BOY'S
SHOWER
GIRL'S
TOILET
COACH'S
LOCKER
CORRIDOR
CORRIDOR
PASS.
J.C.
COACH'S
TOILET
BOYS
WASH
BOYS
SHOWER
BOYS
TOILET
SHAFT
STAIR
STAIR
MEZZANINE
LADDER
STAIR
ELECTRICAL
ROOM
UNISEX
TOILET
OFFICE
LOCKERS
VEST.
VEST.
HALL
CCP
E
E1
E
E
E
E
E
E
E
E
E
E
E
E
E
D R
O P
-IN
H E
A T
E D
S H
E L F
E
E
E12
E
D R
O P
-I N
H E
A T
E D
S H
E L F
E
E13
E12
E
E9
E9
R A
IS
E
D R
A
IL
H O
T
W E
L L
E
E
E13
E
E1
E
E
E
E
E
E
E
E
E
E
E
E
E
D R
O P
-IN
H E
A T
E D
S H
E L F
E
E
E12
E
D R
O P
-I N
H E
A T
E D
S H
E L F
E
E13
E12
E
E9
E9
R A
IS
E
D R
A
IL
H O
T
W E
L L
E
E
E13
CLASSROOM
CLASSROOM
DISCONNECT AND REMOVE CEILING MOUNTED TECHNOLOGY EQUIPMENT
(SPEAKERS, WIRELESS ACCESS POINTS, SECURITY CAMERAS, ETC.) IN THIS AREA
FOR THE DURATION OF CONSTRUCTION. COIL AND LABEL CABLING IN TRUSS
SPACE TO PROTECT. COORDINATE EXTENT OF CEILING REMOVAL WITH
CONSTRUCTION TRADES. REINSTALL EQUIPMENT IN NEW OWNER PROVIDED
CEILING TILES WHEN GENERAL CONSTRUCTION IS COMPLETE. AIM ANY SECURITY
CAMERAS TO OWNER'S SATISFACTION.
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5C
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area C
M A
T C
H L
IN
E
2.
T
3.
5D
2.
T
3.
5J
MATCH LINE
2.T3.5C
2.T3.5B
MATCH LINE
2.T3.5J
2.T3.5C
M A
T C
H L
IN
E
2.
T
3.
5C
2.
T
.5
B
M A
T C
H L
IN
E
2.
T
3.
5D
2.
T
3.
5C
A
B
C
I
DF
G
H
E
E108E107 E106
E105E104E103
E101
E102
E120
E125
E124
E126
E133
D110F120
E127 E129
E128
F119
F116
F113
F115F114
F111F110
F112
F108
J107
F109
E121
E122
J106 J105
H145 H146
H147
H144
H141
H139
H138
H132
H140
H137
H125
H124
H123
H122
J108
J109
E114
F101
H104
E109 E110
E134
E135
E136
E118
F102
F117
F118
H136
H143
J101
J110
F121
E130
E119
ATHLETIC
CLASSROOMCLASSROOMCLASSROOM
CLASSROOMCLASSROOMCLASSROOM
VEST.
COMMONS
CAFETERIA
CAFETERIA
SNACK BAR
SERVING
KITCHEN
RECEIVINGCLASSROOM
HEAD
CUSTODIAN
BREAK RM.
STOR.
STORAGE
IMT LABORATORY
CLASSROOM
WORK
ROOMOFFICE
BOYSGIRLS
J.C.
ART ROOM
CORRIDOR
STORAGE
CLASSROOM
STORAGE
ROOM
BOOK
KEEPING
PRINCIPALS
SECRETARY
PRINCIPAL
MAIN OFFICE
OFFICE
WOMEN
MEN
OFFICE NURSE
ROOM
LAVATORY
RESOURCE CENTER/
MEDIA CENTER
STOR.
STORAGE
AUDIO/
VISUAL
WORK
ROOM
CLASSROOM
SCHOOL
STORE
CORRIDOR
CORRIDOR
CORRIDOR
TOILET TOILET
LOCKERS
TOILET
OFFICE
ELECT.
CORRIDOR
STOR.
STAIR
PASS.
PASS.
STORAGE
DISPLAY
ELECTRICAL
ROOM
STORAGE
ROOM
SCHOOL
STORE
CCP
CCP
E
E1
E
E
E
E
E
E
D R
O P
-IN
H E
A T
E D
S H
E L F
E
E
E12
E
D R
O P
-I N
H E
A T
E D
S H
E L F
E
E13
E12
E
E9
E9
R A
IS
E
D R
A
IL
H O
T
W E
L L
E
E
E13
E
E1
E
E
E
E
E
E
D R
O P
-IN
H E
A T
E D
S H
E L F
E
E
E12
E
D R
O P
-I N
H E
A T
E D
S H
E L F
E
E13
E12
E
E9
E9
R A
IS
E
D R
A
IL
H O
T
W E
L L
E
E
E13
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
127A
CLASSROOM
CLASSROOM
129A
CLASSROOM
CLASSROOM
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5D
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area D
MATCH LINE
2.T3.5J
2.T3.5C
M A
T C
H L
IN
E
2.
T
3.
5D
2.
T
3.
5C
M A
T C
H L
IN
E
2.
T
3.
5F
2.
T
3.
5D
MATCH LINE
2.T3.5I
2.T3.5F
M A
T C
H L
IN
E
2.
T
3.
5D
2.
T
3.
5J
MATCH LINE
2.T3.5I
2.T3.5D
A
B
C
I
DF
G
H
E
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5E
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area E
MATCH LINE
2.T3.5F
2.T3.5E
MATCH LINE
2.T3.5F
2.T3.5E
A
B
C
I
DF
G
H
E
SS S
S
SS S
S
S
S S S
S
S
S
S
S
S
S
S
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
SS SS
SSSS PA
PA
PA
PA
(R)(R) (R) (R)
(R)
(R)(R) (R)
SS
SSSS
SS
REINSTALL SOUND
SYSTEM SPEAKERS
WHEN GENERAL
CONSTRUCTION IS
COMPLETE (TYP OF 4)
REINSTALL PUBLIC
ADDRESS SPEAKERS
WHEN GENERAL
CONSTRUCTION IS
COMPLETE. EXTEND
WIRING AS REQUIRED
(TYP OF 4)
PROVIDE AND INSTALL
TEACHLOGIC SP-628
SPEAKER AND
CONNECT TO EXISTING
AMPLIFIER LOCATED IN
CEILING EQUIPMENT
BOX (TYP OF 4)
CLASSROOM
SS SS
SSSS
PA PA
PAPA
(R)
(R) (R)
(R)
(R)(R)
(R) (R)
DISCONNECT AND
REMOVE PROJECTOR AND
TURN OVER TO OWNER.
REMOVE AV CABLING
BACK TO SOURCE.
REMOVE DATA CABLING
TO CCP ENCLOSURE.
DISCONNECT AND
REMOVE PUBLIC ADDRESS
SPEAKERS FOR THE
DURATION OF
CONSTRUCTION. COIL
CABLING IN TRUSS SPACE
FOR REUSE (TYP OF 4)
DISCONNECT AND REMOVE
SOUND SYSTEM SPEAKERS
FOR THE DURATION OF
CONSTRUCTION. COIL
CABLING IN TRUSS SPACE
FOR REUSE (TYP OF 4)
EXISTING CEILING
EQUIPMENT BOX TO REMAIN.
TEMPORARILY SUPPORT FOR
REMOVAL OF CEILING.
EXISTING IR SENSOR AT
CCP PANEL TO REMAIN.
REMOVE HDMI AND USB
CABLING BACK TO
SOURCE AND PROVDE
BLANKS AT FACEPLATE.
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5F
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area F
M A
T C
H L
IN
E
2.
T
3.
5F
2.
T
3.
5D
MATCH LINE
2.T3.5F
2.T3.5E
MATCH LINE
2.T3.5F
2.T3.5G
MATCH LINE
2.T3.5G
2.T3.5F
MATCH LINE
2.T3.5I
2.T3.5F
MATCH LINE
2.T3.5F
2.T3.5E
1/8" = 1'-0"
CLASSROOM 231 DEMOLITION PLAN
A
B
C
I
DF
G
H
E
FUME
HOOD
G.C.
G.C.
G .C
J117
L104
L106
L117L114
L118L115
L107
L111
L109
L112
L113L143L142
L141L139 L140
L154
L151
L152 L153
L137
L150
L149
L147
L148
L101
L133
L145
L138
L103
L102
L144
L146
L108
L110
L120
L121
L122 L123 L124 L125 L126
L127
L128
L129
L130
L131 L132
L134
L135
L136
L116L114 L117 L104
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOMCLASSROOM
OFFICESTORAGE
BOYS
GIRLS
STORAGE
CLASSROOM
CLASSROOM
COMPUTER
CLASSROOMCLASSROOM
OFFICE
WORK
ROOM
HEAD
END
CLASSROOM
CLASSROOM
WORK
ROOM OFFICE
SCIENCE
CLASSROOM
SCIENCE
CLASSROOM
SCIENCE
CLASSROOM
SCIENCE
CLASSROOM
PREP
ROOM
LOCKERS
COURTYARD
CORR.
CORRIDOR
CORR.
CORR.
CORR.
CORR.
J.C.
ELECT.
OFFICE
CONFERENCE
ROOM
OFFICE OFFICE OFFICE OFFICE OFFICE
WORK
ROOM
OFFICE
OFFICE
TOILET
TOILET
WORK
ROOM
PREP
ROOM
PREP
ROOM
STOR.
CAREER
ROOMCLASSROOM CLASSROOM CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5G
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area G
MATCH LINE
2.T3.5G
2.T3.5F
MATCH LINE
2.T3.5F
2.T3.5G
A
B
C
I
DF
G
H
E
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5H
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area H
MATCH LINE
2.T3.5H
2.T3.5D
MATCH LINE
2.T3.5H
2.T3.5F
A
B
C
I
DF
G
H
E
D101
D155
D152
D105
D110
D124
D139
D116
F120
D102
D103
D106 D107
D108
D109
D111
D112
D113
D114
D104
D115
D117
D118 D119
D120
D121
D122
D123
D125
D126
D127
D128
D129
D130
D131
D132
D133
D134
D135 D136
D137
D138
D140
D141
D142
D143
D144
D145
D146
D147
D148
D149 D150
D151
D154
D153
F121
D156
D157
D158
C139
D159
VESTIBULE
STORAGE
STORAGE
BOILER
ROOM
RECEIVING
GIRLS POOL
LOCKER ROOM
BOYS POOL
LOCKER ROOM
POOL
CLASSROOM
CORRIDOR
CORRIDOR
STAIR SHAFT
STORAGE ELECTRICAL
ROOM
METER
ROOM
PASSAGE
ELECTRICAL
ROOM
ELECTRICAL
ROOM
LOBBY
STAIR
STAIR
ELEC. TOILET
OFFICE
PASSAGE
GIRLS
TOILETS
STORAGE
TOWELS
DRYING
GIRLS
TOILETS
SHAFT
SHOWER
GIRLS
SHOWERS
OFFICE
SHOWER
TOILET
PASSAGE
OFFICE
BOYS
TOILETS
STORAGE
PASSAGE
BOYS
TOLIET
DRYING
TOWELS
STORAGE
BOYS
SHOWERS
STAIR
SHAFT
STORAGE
SHAFT
STAIR
STAIR
STORAGE
MEZZANINE
LADDER
STAIR
ELECTRICAL
ROOM
OFFICE
J.C.
LOCKERS
VEST.
BLEACHER
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5I
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area I
MATCH LINE
2.T3.5D
2.T3.5C
M A
T C
H L
IN
E
2.
T
3.
5D
2.
T
.5
I
MATCH LINE
2.T3.5I
2.T3.5C
A
B
C
I
DF
G
H
E
Q111
Q114
Q115 Q113 Q112
Q110
Q109
Q101
Q102
Q103
Q104
Q106 Q105
Q107
Q108
SAMLL ENGINE
CLASSROOM
FLAM.
LIQUIDS
MECH.
TOOL
CRIB STORAGE
TOOL
CRIB
STORAGE
POWER
MECHANICS
BOYS
ROOM
STORAGE
BOYS LOCKER
ROOM
GIRLS
LOCKER
TOILET
ROOM
OFFICE
AUTO SHOP
M101M102M103
M104 M105 M106
M107
CLASSROOMCLASSROOMCLASSROOM
CLASSROOM CLASSROOM CLASSROOM
CORRIDOR
CLASSROOM
M-6
CLASSROOM
M-4
CLASSROOM
M-2
CLASSROOM
M-1
CLASSROOM
M-3
CLASSROOM
M-5
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.T2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/W C
S W ar re n M ot t H
S -E
.r vt
/2 8/
:3
4:
P M
S. Tyburski
T. Carron
L. Napoli
2.T3.5J
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
1/8"=1'-0"
3131 Twelve Mile Rd.
Warren, MI 48092
Mott Technology Pan - Area J
REMOVE RF CABLING TO NEAREST
TAP LOCATION AND TERMINATE
WITH 75OHM RESISTOR
IR BEACON
SENSOR
3.5MM AUDIO (WITH INLINE
ISOLATION TRANSFORMER)
CRESTRON BPC-8
CONTROLLER
P/S
EXISTING
CATV
CABLE
EXISTING
CATV
SPLITTER
LAN
AUDIO OUT
EXISTING LAN
RELOCATE 8 PORT
POE SWITCH TO
CEILING EQUIPMENT
BOX
EXISTING SMALL OR
LARGE CCP
PANEL ENCLOSURE
EXISTING CATEGORY
CABLING
EXISTING
PAGE
SYSTEM
CABLE
EXISTING PAGE
CONTROL REPLAY
EXISTING 25V
TRANSFORMER
2#16AWG PLENUM
CABLE UNSHIELDED
TO REMAIN
DISCONNECT AND REMOVE CABLING ABOVE
CEILING AT CCP LOCATION. REROUTE
CABLING INTO NEW WIREMOLD V4000
RACEWAY (V4000 BY OTHERS)
EXISTING 1-GANG FACEPLATE
W/1-VOICE TO REAMIN
USB
EXISTING 8 OHM
PAGE SPEAKERS
(QUANTITY 1 OR 2 UNLESS
OTHERWISE NOTED)
P/S
120V15V
SS SS
SS SS
120V
12V
CRESTRON BPC-8-IMC
IR BLASTER
COM
IR-1
SPEAKER OUT
SPEAKER OUT
ALS OUT
BEACON SENSOR
A3
EXISTING AV FACEPLATE
2#20
RS232
IR
EXISTING DATA FACEPLATE
USB CABLING
HDMI 2
HDMI 1
AUX IN
(MOUNTED IN CEILING TILE ADJACENT
TO CCP PANEL)
EXISTING USB
EXTENDER (LOCATED
BEHIND DISPLAY OR ON
TOP OF PROJECTOR)
EXISTING CAT5E CABLING. REROUTE
CABLING FROM PROJECTOR OR DISPLAY
TO NEW SWITCH LOCATION (CEILING
BOX). RETERMINATE AND TEST.
CABLING ROUTED THROUGH WIREMOLD
V4000 GROMMETED OPENING
EXISTING PLENUM RATED CEILING
ENCLOSURE OR WALL CABINET
EXISTING USB VIA CAT 6 CABLING
EXISTING KRAMER CP-AOCH/XL
ACTIVE OPTICAL HDMI CABLE
EXISTING INTERACTIVE DISPLAY
OR INTERACTIVE PROJECTOR
EXISTING CATEGORY
CABLING
S
SS
S
CLASSROOM CONNECTION DIAGRAM (CCP
PANEL ENCLOSURES - DEMOLITION PLAN
NO SCALE
DISCONNECT AND REMOVE CABLING
ABOVE CEILING AT CCP LOCATION.
REROUTE CABLING INTO NEW WIREMOLD
V4000 RACEWAY (V4000 BY OTHERS)
DISCONNECT AND REROUTE
CABLING TO CEILING EQUIPMENT
BOX. RETERMINATE AND TEST.
2.T5.1
RELOCATE PAGE CONTROL
RELAY, TRANSFORMER AND
ASSOCIATED WIRING TO
CEILING EQUIPMENT BOX
CLASSROOM CONNECTION DIAGRAM
(CCP PANEL ENCLOSURES - NEW WORK PLAN)
NO SCALE
IR BEACON
SENSOR
AUDIO OUT
EXISTING LAN
EXISTING
PAGE
SYSTEM
CABLE
REROUTE CABLING INTO NEW WIREMOLD
V4000 RACEWAY (V4000 BY OTHERS)
USB
P/S
120V15V
SS SS
SS SS
SPEAKER OUT
SPEAKER OUT
ALS OUT
BEACON SENSOR
FACEPLATE TYPE "A"
LAN
IR
USB CABLING
HDMI 2
HDMI 1
AUX IN
(MOUNTED IN CEILING TILE ADJACENT
TO CCP PANEL)
EXISTING USB
EXTENDER (LOCATED
BEHIND DISPLAY OR ON
TOP OF PROJECTOR)
EXISTING PLENUM RATED CEILING
ENCLOSURE OR WALL CABINET
EXISTING USB VIA CAT 6 CABLING
EXISTING KRAMER CP-AOCH/XL
ACTIVE OPTICAL HDMI CABLE
EXISTING INTERACTIVE DISPLAY
OR INTERACTIVE PROJECTOR
S
SS
S
DISCONNECT AND REMOVE CABLING
ABOVE CEILING AT CCP LOCATION.
REROUTE CABLING INTO NEW WIREMOLD
V4000 RACEWAY (V4000 BY OTHERS)
RELOCATED 8-PORT
SWITCH
EXISTING REROUTED
CATEGORY CABLING EXISTING REROUTED 2#20
EXISTING REROUTED
3.5MM AUDIO (WITH
INLINE ISOLATION
TRANSFORMER)
RELOCATED PAGE
CONTROL REPLAY
RELOCATED 25V
TRANSFORMER
A3
EXISTING REROUTED
CATEGORY CABLING
CAT6 PLENUM RATED
2#16AWG PLENUM
CABLE UNSHIELDED
EXISTING 8 OHM
PAGE SPEAKERS
(QUANTITY 1 OR 2 UNLESS
OTHERWISE NOTED)
12V
120V
2.T5.1
EXISTING REROUTED
3.5 FOR ALS OUT
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/T ec hn ol og y
D et ai ls rv t
/2
8/
:0 7:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T5.1
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
No Scale
AV Functional Diagrams
COVERPLATE
SMALL CCP ENCLOSURE ELEVATION WITH
TEACHING STATION - DEMOLITION PLAN
NO SCALE
2.T7.1
FINISH FLOOR
EXISTING 120V QUAD
OUTLET TO BE REMOVED
BY OTHERS
FINISH CEILING
x;
16"
NOTE:
EXISTING DUPLEX OUTLETS
MOUNTED BEHIND
COVERPLATE TO BE REMOVED
BY OTHERS
REMOVE CCP PANEL
ENCLOSURE COVER
AND TURN OVER TO
OWNER
EXISTING TELEPHONE PLATE
1. REFER TO CONNECTION DIAGRAM 1 AND 2 ON DRAWING T5.1
FOR ADDITIONAL REQUIREMENTS.
REMOVE RF CABLING
TO NEAREST TAP
LOCATION AND
TERMINATE WITH
75OHM RESISTOR
RELOCATE EXISTING 1/4" S-
HOOK FOR STRAIN RELIEF.
REFER TO NEW WORK V4000
ELEVATION FOR NEW
LOCATION.
DISCONNECT AND REMOVE CRESTRON BPC-8
CONTROL PANEL IN IT'S ENTIRETY. REMOVE
ALL ASSOCIATED WIRING AND EQUIPMENT
TO AND WITHIN CEILING EQUIPMENT BOX
AND TO THE DISPLAY SOURCE.
DISCONNECT AND REMOVE ONE (1) RJ45 JACK
FOR VOICE (GRAY) AND ONE (1) RJ45 JACK
FOR DATA (RED) TO CLASSROOM NETWORK
SWITCH LOCATED IN CCP PANEL.
DISCONNECT AND REMOVE TWO (2) HDMI, ONE
(1) 3.5MM AUDIO (ALS), ONE (1) RJ45 JACK FOR
USB (YELLOW) TO ABOVE CEILING. COIL AND
LABEL CABLING FOR REUSE.
CONSTRUCTION TRADES TO DISCONNECT AND
REMOVE CLASSROOM CONTROL PANEL (CCP)
ENCLOSURE.
RELOCATE 8-PORT NETWORK SWITCH TO
CEILING BOX LOCATION. REMOVE PATCH
CABLING TO DATA/VOICE AT 18" AFF COMPLETE.
FINISH CEILING
NOTE:
REMOVE RF CABLING TO
NEAREST TAP LOCATION
AND TERMINATE WITH
75OHM RESISTOR
EXISTING DUPLEX OUTLETS
MOUNTED BEHIND
COVERPLATE TO BE
REMOVED BY OTHERS
RELOCATE EXISTING S-
HOOK FOR STRAIN RELIEF
TO REMAIN. REFER TO
NEW WORK V4000
ELEVATION FOR NEW
LOCATION.
EXISTING 120V QUAD
OUTLET TO BE REMOVED
BY OTHERS
1. REFER TO CONNECTION DIAGRAM 1 AND 2 ON DRAWING T5.1 FOR ADDITIONAL REQUIREMENTS.
x;
15x;1/2
REMOVE CCP PANEL ENCLOSURE
COVER AND TURN OVER TO OWNER
EXISTING TELEPHONE PLATE
LARGE CCP ENCLOSURE ELEVATION WITH
TEACHING STATION - DEMOLITION PLAN
NO SCALE
2.T7.1
DISCONNECT AND REMOVE ONE (1) RJ45 JACK
FOR VOICE (GRAY) AND ONE (1) RJ45 JACK
FOR DATA (RED) TO CLASSROOM NETWORK
SWITCH LOCATED IN CCP PANEL.
DISCONNECT AND REMOVE TWO (2) HDMI, ONE
(1) 3.5MM AUDIO (ALS), ONE (1) RJ45 JACK FOR
USB (YELLOW) TO ABOVE CEILING. COIL AND
LABEL CABLING FOR REUSE.
CONSTRUCTION TRADES TO DISCONNECT AND
REMOVE CLASSROOM CONTROL PANEL (CCP)
ENCLOSURE
DISCONNECT AND REMOVE CRESTRON BPC-8
CONTROL PANEL IN IT'S ENTIRETY. REMOVE
ALL ASSOCIATED WIRING AND EQUIPMENT TO
AND WITHIN CEILING EQUIPMENT BOX AND TO
THE DISPLAY SOURCE.
RELOCATE 8-PORT NETWORK SWITCH TO
CEILING BOX LOCATION. REMOVE PATCH
CABLING TO DATA/VOICE AT 18" AFF
COMPLETE.
V4000 ELEVATION DETAIL
NO SCALE
2.T7.1
FINISH FLOOR
FINISH CEILING
V4010DFO CONDUIT
ENTRANCE FITTING BY EC
FACEPLATE TYPE "A"
V4000 RACEWAY
BASE, DIVIDER,
COVER, AND END CAP
BY EC
INSTALL BUSHING FOR
CABLING LEAVING V4000
120VAC BY EC
V4050 DEVICE
MOUNTING
BRACKET BY EC
120VAC BY EC (TYP)
REINSTALL 1/4" S-HOOK FOR STRAIN
RELIEF. POSITION HOOK ON THE SIDE
OF ROOM FACING THE CLASSSROOM
AND NOT THE EXTERIOR WALL
WHENEVER POSSIBLE.
Project Title
Key Plan
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2023 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
2022 Bond Program Technology Renovations to
Support Construction Activities Base Bid No.2
22177-1000
BPT2
design design©
A ut od es k D oc s:
//W ar re n
C on so lid at ed
S ch oo ls
/T ec hn ol og y
D et ai ls rv t
/2
8/
:0 7:
P
M
S. Tyburski
T. Carron
L. Napoli
2.T7.1
S. Tyburski
M. Nowicki
S. Tyburski
Warren Consolidated Schools
No Scale
Details
FACEPLATE TYPE "A"
NOTE:
1. ALL MODULES AND BLANKS SHALL BE IVORY IN COLOR.
HUBBELL HWAPLOW
ANGLED MODULE
ANGLED MODULE
WIREMOLD
V4…
This is the start of the file's text. The full file is on GovTribe.