W91ZRU-18-Q-5027

Attachment 1: PRICING SCHEDULE

LINE ITEM
DESCRIPTION
QTY
UI
UNIT PRICE
EXTENDED PRICE
0001:
MFR: Cv International; Model #: SNGII-40815; NSN #: 3655-01-505-7616; Description: Stationary Nitrogen Generator (SNG-II) OR EQUAL

Must meet the following physical, salient characteristics:

· Produce nitrogen gas at least 95% purity

· Nitrogen used must be dry gas

· Nitrogen gas produced must not contain oil residue

· Service pressures provided to 3000+psi

· Ability to continually monitor the oxygen content to determine nitrogen purity

· Control center with PLC controller via touch screen interface allowing the operator to control the operation of the system and monitor all phases of system status.

· Gas quality of -70° C Atmospheric Dew Point

· Max PSI of 5000

· Power @ 3 Phase/60Hz

- 460 VAC

- 79 FLA

1
EA
0002
MFR: Cv International; Model #: SNGII-40815; NSN #: 3655-01-505-7616; Description: Nitrogen Generator Spares Kit (1000 Hours) OR EQUAL
1
EA
0003
MFR: Cv International; Part/Model #: RCK-37/REG PNL (2 outlet); Description: Regulator Panel 2 Outlets OR EQUAL
1
EA
0004
MFR: Cv International; Part/Model #: R3X1V-UN-50-BULK06-0-N; Description: Six Nitrogen Cylinders Storage Assembly OR EQUAL
1
EA
0005
MFR: Cv International; Part/Model #: CVI-5000X20FT; Description: High Pressure Hoses OR EQUAL

Must meet the following physical, salient characteristics:

· Solid, fixed pressure hose

· Capable of withstanding 5000 PSI

· Must include adequate shutoffs to isolate/safe installed components

1
EA
NOTE
CLINS 0001-0005 above must include a minimum full replacement warranty for 1 year along with limited lifetime warranty***
-
-
0006
Factory Training And Commissioning

Includes:

- Disconnect and removal of old generator unit

- Clean and prep generator room for installation

- Install new units

- Test and commission units

- Train personnel on operation of equipment/generator

Should also include costs for installation, to include mechanic/installer hours, hardware, consumable supplies and any other expenses associated with install and training.

1
JOB
0007
Shipping FOB DESTINATION to JBER, AK 99506
1
EA
NOTE
***The successful awardee must be able to provide services/repairs within 72 hours from notification due to possible mission stoppage. All services/repairs are separate from the resultant contract and will incur separate costs.***
-
-

TOTAL PRICE:

***Shipping costs to FOB Destination (JBER, Alaska 99506) MUST be included within the unit price.***

**Quotes are hereby good until 30 September 2018. **

Business Size: Small Large Women-Owned Veteran-Owned Other:__________________________

Net Terms (Mandatory):
CAGE
DUNS:
Printed Name
Title
Signature
Date

NOTE: The individual signing must be a signatory official for this Entity; signature constitutes agreement to all terms/conditions contained within this solicitation.