B01 Solicitation Amendment_Government Responses to Industry_Gun Barrel MDI Booth.pdf
PDF 123 KB Posted
- Attached to
- Gun Barrel Magnetic Particle Inspection Booth
- Solicitation number
- W91ZLK-24-Q-0012
About this file
This document is a solicitation amendment that provides the government's responses to industry questions regarding a Request for Quote (RFQ) for a Gun Barrel Magnetic Particle Inspection Booth. The solicitation, number W91ZLK-24-Q-0012, is a 100% small business set-aside under NAICS code 334519, Other Measuring and Controlling Device Manufacturing. The government is seeking to procure one (1) Gun Barrel Magnetic Particle Inspection Booth in accordance with the attached Statement of Work. The responses address questions related to the dimensions of the cannon tubes, crane height and capacity, training requirements, and payment terms. The solicitation requires proposals to be submitted by 1:00 PM EST on April 15, 2024, with the award to be made on the basis of lowest price, technically acceptable offer.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ques�on 1: Paragraph 6.9B Central Conductors
Will the government provide the length of the central conductors needed and maximum diameter of the spacers used for the central conductors to fit the following cannon tubes:
M1299, M776, M284, M256, M20 and M137
Response 1: The length of conductors will be determined by the design of the head and tail stock, and how the cannon tube sits on the machine. M1299 tubes are approximately 360” long with 6” diameter spacers, M776 and M284 tubes approximately 240” long with 5.75” spacers, M256 tubes are approximately 210” long with 4.5” spacers, M35 tubes are approximately 215” long with 4” spacers, M20 and M137 tubes approximately 130” long with 4” diameter spacers. The diameter of the conductor should be appropriate for the current used. Conductors currently in use, and which would be appropriate are 2.5”ID 0.65 wall thickness copper with lengths varying from 15� to 26�.
Ques�on 2: What is the height clearance below the lowest point of the bridge crane to the floor in the planned loca�on of the gun tube unit?
Response 2: Approximately 14�.
Ques�on 3: What is the li� capacity of the bridge crane that will be used to transport the new unit into place?
Response 3: 10 ton
Ques�on 4: Is there any training requirement for operators or maintenance personnel once the new system is in place and opera�onal?
Response 4: No
Ques�on 5: Will the government consider progress payments based on specific milestones for this RFQ?
Response 5: At this �me, the government does not consider progress payments based on specific milestones for this solicita�on.
File details come from the government source that posted it. Updated .