Item # Chamber
ID #/SN
Bldg Location
| Calibration |
| LABORATORY INSTRUMENTATION LIST/ |
NO OF CAL POINTS
| 1 |
| AB-1 (Walk-in) |
| Custom system, Bally Box Box/Honeywell Chart recorder, Watlow F4 Controller |
| 9830 |
| 362 |
| Yes |
| T&H / 4 Temps-2 %RH readings (50 and 95%) |
| 2 |
| AB-2 (Walk-in) |
| Custom system, Bally Box Box/Honeywell Chart recorder, Watlow F4 Controller |
| 0581 |
| 362 |
| Yes |
| T&H / 4 Temps-2 %RH readings (50 and 95%) |
| 3 |
| AB-4 |
| SES, Watlow Controller |
| 1846-S-10204 |
| 5014 |
| Yes |
| T&H 32 cu ft / 3 Temps readings |
| 4 |
| AB-5 (Thermo) |
| Thermo, Walow F4 |
| 33647 |
| 362 |
| Yes |
| T 16 cu ft / 3 Temps readings |
| 5 |
| AB-6 |
| Cincinatti Sub Zero, 560 controller |
| ZP1132828 |
| 5014 |
| Yes |
| T&H 32 cu ft / 4 Temps (no humidity) |
| 6 |
| ABCZ-9 (Altitude) |
| Cincinatti Sub Zero 560 controller |
| 10-CA-15041 |
| 372 |
| Yes |
| T, Pressure 16 cu ft /3 temps-no pressure readings |
| 7 |
| ABCZ-11 |
| Cincinatti Sub Zero 560 controller |
| ZP0821607 |
| 372 |
| Yes |
| T&H 32 cu ft / 4 Temps-2 %RH readings (50 and 95%) |
| 8 |
| ABCZ-10 |
| Cincinatti Sub Zero 560 controller |
| ZP0821606 |
| 362 |
| Yes |
| T&H 32 cu ft / 4 Temps-2 %RH readings (50 and 95%) |
| 9 |
| ABCZ-12 |
| Cincinatti Sub Zero 560 controller |
| ZP1132838 |
| 5014 |
| Yes |
| T&H 32 cu ft / 4 Temps-2 %RH readings (no sheathed heaters) (50 and 95%) |
| 10 |
| ABCZ-13 |
| Cincinatti Sub Zero 560 controller |
| ZP0631131 |
| 372 |
| Yes |
| T&H 32 cu ft / 4 Temps-2 %RH readings (50 and 95%) |
| 11 |
| ABCZ-14 |
| Cincinatti Sub Zero 560 controller |
| ZP0711197 |
| 372 |
| Yes |
| T&H 64 cu ft / 4 temps-2 %RH readings ( 50 and 95%) |
(Temp Shock) Cincinatti Sub Zero 560 controller
| 15VT16037 |
| 372 |
| Yes |
| T&H 8 cu ft / 2 compartments/ 4 temps (2 each) |
T=Temperature/H=Percent Relative Humidity (%RH)
R1, R2, R3
16090678, 10411,-0155806101161015
| Repairs only |
| Laboratory Refrigerators |
General fume hoods
| Mechanical maintenance/repairs (motors/fans/belts) |
| Fume Hoods (1-B362/2-B372/1-B400/5-B363) |
| 15 |
| SP1 through SP5 |
| General make |
| Mechanical Repairs only |
| Spot Hoods B363 |
| Preventative maintenance/Repairs |
| Mobile Instrumentation Trailers |
REFRIGERANTS
| Chamber |
| SN |
| Refrigerants |
| Amount |
| Bldg |
| AB-1 |
| 9830 |
| R507 / R23 |
| 60/60 lbs |
| 362 |
| AB-2 |
| 581 |
| R507 / R23 |
| 60/60 lbs |
| 362 |
| AB-4 |
| 10204 |
| R502 |
| 2 lbs 12 oz |
| 5014 |
| AB-5 |
| 33647 |
| 508/404A |
| 3.0/8.0 |
| 362 |
| AB-6 |
| 1132828 |
| 404A / 508B |
| 5.5 / 2.0 |
| 5014 |
| ABCZ-9 |
| 10-CA15041 |
| 404A / 508B |
| 8.0/2.2 |
| 372 |
| ABCZ-10 |
| 821606 |
| 404A / 508B |
| 5.5 / 2.0 |
| 362 |
| ABCZ-11 |
| 821607 |
| 404A / 508B |
| 5.5 / 2.0 |
| 372 |
| ABCZ-12 |
| 1132838 |
| 404A / 508B |
| 5.5 / 2.0 |
| 362 |
| ABCZ-13 |
| 631131 |
| 404A / 508B |
| 5.5 / 2.0 |
| 372 |
| ABCZ-14 |
| 711197 |
| 404A / 508B |
| 11.0/2.8 |
| 372 |
| ABCZ16 |
| 15VT16037 |
| 404A / 508B |
| 47.0/8.0 |
| 372 |
| B363 Instrumentation Trailers |
| 1 |
| R22 |
| 54 oz ea |
| 363 Mobile |
| 2 |
| R22 |
| 54 oz ea |
| 363 Mobile |
| 3 |
| R22 |
| 54 oz ea |
| 363 Mobile |
| 4 |
| R22 |
| 54 oz ea |
| 363 Mobile |
| 5 |
| R22 |
| 54 oz ea |
| 363 Mobile |
| 6 |
| R22 |
| 54 oz ea |
| 363 Mobile |
Laboratory Refrigerators
| 16090678 |
| 1 |
| 134A |
| 20 oz |
| 363 |
| 155806101161015 |
| 3 |
| 134A |
| 11 oz |
| 363 |