SOW_Attachment_for_Hoist_Repair.pdf

PDF 190 KB Posted

Attached to
Crane Inspection and Repair
Solicitation number
W91SMC-19-Q-7002
Issued by

About this file

Statement of work for Crane and Hoist repair

View the file

Other files

File Type Posted
Hook_and_Chain_Dimensions.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Customer Information

Customer 183d Wing

Location 1301 N Macarthur Blvd Springfield

Customer Contact CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.mill

Contact

Assets

P-17 NDI Room 5

Monorail system - 1 trolley electric chain hoist, P-17 NDI

Business Location

183d Wing 3101 J David Jones Pkwy

Springfield

CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.mil

Risk Recommendation Code Description Fault Comments USD

Safety Risk Replace 1-82448669100 Chain container no container Supply and install new chain container.

Hoist missing a chain container.

Safety Risk Lubrication Maintenance

1-82448668991 Thrust ball bearing

Improper lubrication, thrust bearings

Supply and install new thrust bearing.

Recommend disassembly of hook block to determine if thrust bearing needs replaced or just lubricated.

P-17 NDI Room 5

P-01 Bridge 2 Hoist A/B

Single girder EOT - 2 trolleys Yale wire rope hoists, North Bay West

Business Location

Contact

183d Wing 3101 J David Jones Pkwy

Springfield

CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.milmil

Risk Recommendation Code Description Fault Comments USD

Safety Risk Replace 1-82859031738 Operation control

Circuitry bypassed

Supply and install new phase detection device.

Phase detection device’s status indicator does not illuminate. Also, the circuitry has been bypassed which could allow the hoist brake to release even if the motor is missing a phase.

Safety Risk Repair 1-82859031963 Operation control

Circuitry bypassed

Supply labor remove jumper from circuit.

Phase detection device is bypassed which could allow the hoist brake to release even when missing a phase.

Production Risk

Repair 1-82859022758 Tow arm Improper mounting

Quote available upon request.

Tow arm assembly needs stiffened. Tow arm and collector assemblies vibrate while in motion.

P-01 Bridge 2 Hoist A/B

3101 J David Jones Pkwy

Springfield

CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.mil

Risk Recommendation Code Description Fault Comments USD

Production Risk

Repair 1-82859089664 Tow arm Improper mounting

Quote available upon request.

Tow arm and collector assemblies vibrate when traveling down the conductor.

0.00

Safety Risk Replace 1-82859112169 Operation control

Other fault Supply and install new high speed contactor.

Hoist high speed contactor coil intermittently chatters during high speed operation.

Safety Risk Replace 1-82859088941 Hoisting wire rope

Broken wires Supply and install new wire rope on Hoist B.

Hoisting wire rope has broken wires.

Safety Risk Replace 1-82859112169 Operation

Circuitry bypassed

Supply and install new phase detection device.

Phase detection device’s status indicator does not illuminate. Also, circuitry is bypassed which could allow hoist brake to release even

Safety Risk Replace 1-82859112044 Operation

Circuitry bypassed

Supply and install new phase detection device.

Phase detection device’s status indicator does not illuminate. Also, circuitry is bypassed

P-01 Bridge 3 Hoist A/B

P-01 Bridge 1 Hoist A/B

Single girder EOT - 2 trolleys Yale wire rope hoists, South Bay East

3101 J David Jones Pkwy

Springfield

CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.mil

Risk Recommendation Code Description Fault Comments USD

Safety Risk Replace 1-82859190000 Operation control

Circuitry bypassed

Supply and install new phase detection device.

Phase detection device’s status indicator does not illuminate. Also, circuitry is bypassed if a phase is missing.

Safety Risk Repair 1-82859190425 Operation

Circuitry bypassed

Supply labor remove jumper from circuit.

Phase detection circuitry is bypassed.

Safety Risk Replace 1-82859164617 Hoisting wire rope

Broken wires Supply and install new wire rope on hoist B.

Hoisting wire rope has broken wires.

P-01 Bridge 1 Hoist A/B

P-01 Bridge 4 Hoist A/B

Single girder EOT - 2 trolleys Yale wire rope hoists, South Bay East

3101 J David Jones Pkwy

Springfield

CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.mil

Risk Recommendation Code Description Fault Comments USD

Safety Risk Replace 1-82859270491 Operation control

Circuitry bypassed

Supply and install new phase detection device.

Phase detection device’s status indicator does not illuminate. Also the circuitry is bypassed when a phase is missing.

Safety Risk Replace 1-82859270306 Operation

Circuitry bypassed

Supply and install new phase detection device.

Phase detection device’s status indicator does not illuminate. Also, circuitry is bypassed which could allow the hoist brake to release even if a phase is missing.

P-01 Bridge 4 Hoist A/B

P-12 AGE Monorail

Monorail system - 1 trolley electric wire rope hoist, P-12

3101 J David Jones Pkwy

Springfield

CMSgt Brent Keller 217-757-1251 brent.d.keller.mil@mail.mil

Risk Recommendation Code Description Fault Comments USD

Safety Risk Repair 1-82933179662 Pushbutton pendant cable

Improper mounting

Supply labor and materials to mount strain relief correctly.

Strain relief mounted improperly.

P-12 AGE Monorail

Total for all assets

Travel

Comments l l .

File details come from the government source that posted it.