This amendment to a solicitation provides updated information for a multiple award indefinite delivery/indefinite quantity contract for general building repair and construction services at USAG Humphreys in Area III. The amendment answers vendor questions, updates the statement of work and pricing schedule, and changes the solicitation closing date from August 30 to September 21, 2020. The contract will be awarded by the Department of the Army Materiel Command Army Contracting Command to provide various construction labor, equipment, materials, and site work for repair and construction projects at the specified military installation over the lifetime of the contract.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base

PRICING SCHEDULE
Multiple Award Indefinite Delivery/Indefinite Quantity (MA IDIQ) Contract for General Building Repair and Construction, USAG Humphreys, Area III
DESCRIPTION: The contractor shall provide all necessary resources including material, labor, transportation and equipment to successfully complete the General Building Repair and Construction, USAG Humphreys, Area III, in accordance with the statement of work, specifications, drawings, and terms and conditions.
Contract Period : Base
SubCLINDESCRIPTIONQTYUNITUNIT PRICEAMOUNT
0001General construction

Mobilization labor for job site

0001AABoiler worker30MDWW
0001ABCarpenter (Concrete form)50MDWW
0001ACCarpenter (Construction)30MDWW
0001ADCarpenter (Door&window)50MDWW
0001AECommon labor50MDWW
0001AFConcrete worker20MDWW
0001AGCommunication worker20MDWW
0001AHDuct worker20MDWW
0001AJExterior electrician30MDWW
0001AKGlazer100MDWW
0001ALInsulation worker70MDWW
0001AMInterior electrician100MDWW
0001ANInterior finish worker20MDWW
0001APMason20MDWW
0001AQMechanical equipment installer20MDWW
0001ARPainter20MDWW
0001ASPlumber20MDWW
0001ATPaving worker50MDWW
0001AURoof worker20MDWW
0001AVSteel worker50MDWW
0001AWTile worker20MDWW
0001AXWater proofing worker50MDWW
0001AYWelder100MDWW
0001AZProject manager100MDWW
0001BASafety manager100MDWW
0001BBQuality controller100MDWW
0002General construction

Mobilization equipment with operator for job site

0002AABackhoe 0.620EDWW
0002ABBackhoe 0.420EDWW
0002ACBackhoe 0.250EDWW
0002ADConcrete pump truck 43m20EDWW
0002AECrane wheel type 250t5EDWW
0002AFCrane wheel type 200t10EDWW
0002AGCrane wheel type 160t10EDWW
0002AHCrane wheel type 130t10EDWW
0002AJCrane wheel type 100t10EDWW
0002AKCrane wheel type 80t5EDWW
0002ALCrane wheel type 50t5EDWW
0002AMDump 15t20EDWW
0002ANFork lift 5t20EDWW
0002APFork lift 7.5t20EDWW
0002AQTrailer 20T20EDWW
0002ARTruck, cargo 4.5T50EDWW
0002ASBackhoe 0.6 w/ breaker20EDWW
0002ATBackhoe 0.2 w/ breaker20EDWW
0003General construction

Site temporary work

0003AAPE safety fence300LMWW
0003ABEGI Safety fence 2.4m for 3 months200LMWW
0003ACEGI Safety fence 2.4m for 6 months200LMWW
0003ADDouble cord scaffolding with temporary stair or slope for 3 month rental, base on H30.0m500SMWW
0003AEDouble cord scaffolding with temporary stair or slope for 6 month rental, base on H30.0m500SMWW
0003AFRolling trestle scaffolding, 6'x4', for 3month rental, base on H2.0m50EAWW
0003AGRolling trestle scaffolding, 6'x4', for 6month rental, base on H2.0m50EAWW
0003AHRolling trestle scaffolding, 6'x4', for 3month rental, base on H4.0m50EAWW
0003AJRolling trestle scaffolding, 6'x4', for 6month rental, base on H4.0m50EAWW
0003AKShoring (h4.0m,B1.5m)1LMWW
0004General construction

Site clean up

0004AATreatment of Construction waste1TONW
0004ABTreatment of designated landfill waste1TONW
0005Concrete

DPW Guide Specifications, Division 03 Case - In - Place Concrete DPW Guide Specifications, Section 03 30 00

0005AAFabricate standard concrete forms for pad, slab, retaining wall, cantilever wall, foundation, pedestal wall, culvert, column, beam, girder and all R.C structure, form height: below 3,048mm, included form tie, wedge fin, spacer, chamfer strip, hook, clamp and all other supporting form accessories288SMWW
0005ABFabricate standard concrete forms for pad, slab, retaining wall, cantilever wall, foundation, pedestal wall, culvert, column, beam, girder and all R.C structure, form height: 3,048 thru 6,096mm, included form tie, wedge fin, spacer, chamfer strip, hook, clamp and all other supporting form accessories260SMWW
0005ACInstall Metallic or Non-Metallic water stop with adhesive and sealant30LMWW
0005ADInstall dowel bar with cap on expansion joint, Below 30D, Length: 600mm40EAWW
0005AEInstall expansion/Contraction joint filler, 130mm thick24SMWW
0005AFFabricate deformed reinforce steel bars, D10 thru D29, for pad, slab, retaining wall, cantilever wall, foundation, pedestal wall, culvert, column, beam, girder and all R.C structure, Per 100kg of standard KS D 3629 reinforcing steel fabrication60100
KGWW
0005AGPlace welded wire fabric in concrete slab or pad, #4, 150 x 150mm225SMWW
0005AHInstall reinforced Conc. 4'W Step included base course and step nosing24SMWW
0005AJPlace 27MPa ready mixed concrete by backhoe, included surface finish, vibrator and operators with equipment, Below 6CM per 1 placing72CMWW
0005AKPlace 27MPa ready mixed concrete by backhoe, included surface finish, vibrator and operators with equipment, Above or equal 6CM per 1 placing108CMWW
0005ALPlace 27MPa ready mixed concrete, included surface finish and vibrator under below 100CM (Add below pump truck)72CMWW
0005AMPlace 27MPa ready mixed concrete, included surface finish and vibrator, 100CM thru 200CM (Add below pump truck)108CMWW
0005ANConcrete pump truck rental cost less than 4 hours12EAWW
0005APConcrete pump truck rental cost, full days, 8 hours18EAWW
0005AQRemoval of asphalt concrete18CMWW
0005ARRemoval of reinforced concrete18CMWW
0005ASRemoval of concrete18CMWW
0006Earthwork

DPW Guide Specifications, Division 31 Earth Work DPW Guide Specification, Section 31 00 00

0006AAExcavation50CMWW
0006ABDisposal of Soil50CMWW
0006ACEngineering Fill50CMWW
Wire Mash Gabions

DPW Guide Specification, Section 31 36 00

0006ADInstall Gabion100SMWW
0007Exterior Improvements

DPW Guide Specifications, Division 32 Subbases for Flexible Paving DPW Guide Specification, Section 32 11 20

0007AAInstall 280mm thk Sub-Base Course120SMWW
Aggregate Base Courses

DPW Guide Specification, Section 32 11 23

0007ABBase course levelling and compaction density 95%200CMWW
0007ACInstall 125mm thk Base Course1,200SMW
0007ADInstall 150mm thk Base Course1,200SMWW
Hot Mix Asphalt for Roads

DPW Guide Specification, Section 32 12 16

0007AEAC. Surface Milling - 50mm thk.100SMWW
0007AFAC. Surface Milling - 75mm thk.100SMWW
0007AGAC. Surface Milling - 100mm thk.100SMWW
0007AHTemporary Road (Gravel), 300mm thk100SMWW
0007AJInstall or Overlay 50mm thk. A/C (#78)4,000SMWW
0007AKInstall or Overlay 75mm thk. A/C (#78)4,000SMWW
0007ALInstall or Overlay 100mm thk. A/C (#78)4,000SMWW
Portland Cement Concrete Pavement for Roads and Site Facilities

DPW Guide Specification, Section 32 13 13. 06

0007AMInstall 100mm thk. Reinforced Conc. Slab100SMWW
0007ANInstall 100mm thk. Conc. Slab100SMWW
0007APInstall 150mm thk. Reinforced Conc. Slab100SMWW
0007AQInstall 150mm thk. Conc. Slab100SMWW
0007ARInstall 200mm thk. Reinforced Conc. Slab100SMWW
0007ASInstall 200mm thk. Conc. Slab100SMWW
0007ATInstall 250mm thk. Reinforced Conc. Slab100SMWW
0007AUInstall 250mm thk. Conc. Slab100SMWW
0007AVInstall 300mm thk. Reinforced Conc. Slab100SMWW
0007AWInstall 300mm thk. Conc. Slab100SMWW
Concrete curbs, gutters, sidewalks, swales and ditches

DPW Guide Specification, Section 32 16 19

0007AXInstall Sidewalk with Base Course, expansion and contraction joint, bloom finish and chamfered edge2,400SMWW
0007AYInstall Conc. Curb1,600LMWW
0007AZInstall Granite Stone Curb400LMWW
0007BAInstall Conc. Gutter1,600LMWW
0007BBConstruct conc. Drainage/Surface Inlet including Cast Iron Grating and drain manhole5EAWW
0007BCInstall handrail50LMWW
0007BDInstall 190mm x 90mm x 57mm red brick wall50SMWW
Pavement Markings

DPW Guide Specification, Section 32 17 23

0007BEPaint reflective, 100mm wide pavement marking include bead3,600LMWW
0007BFPaint reflective, 150mm wide pavement marking include bead3,600LMWW
0007BGPaint reflective, 150mm, 300mm or/and 600mm Marking letter include bead300EAWW
0007BHPaint reflective marking Handicap symbol120EAWW
0007BJPaint 100mm wide stripe, reflective parking stall painting (Per EA)1,000EAWW
0007BKPaint 150mm wide stripe, reflective parking stall painting (Per EA)400EAWW
0007BLInstall Traffic/Parking sign Board with 2"Dia Stl. Post & brackets50EAWW
0007BMInstall information sign Board with 2"Dia Stl. Post & brackets50EAWW
0007BNInstall Handicap parking sign 2"Dia Stl. Post & brackets50EAWW
0007BPInstall vehicle Wheel Stop50SETWW
Chain Link Fences and Gates

DPW Guide Specification, Section 32 31 13

0007BQInstall chain link fence with barbed wire on single arm, Type FE-6, Fabric width: 2,100 thru 2,400 included concrete footing100LMWW
0007BRInstall chain link fence with barbed wire on double arm, Type FE-7, Fabric width: 2,100 thru 2,400 included concrete footing100LMWW
0007BSInstall chain link fence with barbed wire and concertina wire on double arm, Type FE8, Fabric width: 2,100 thru 2,400 included concrete footing50LMWW
0007BTInstall double swing gate with gate posts, Type FE-6/7 included hinge, drop rod, latch assembly, grounding rod, wire and clamp4EAWW
0007BUInstall personnel gate with gate posts, Type FE-6/7 included hinge, drop rod, latch assembly, grounding rod, wire and clamp2EAWW
Seeding

DPW Guide Specification, Section 32 92 19

0007BVInstall Seeding50SMWW
Sodding

DPW Guide Specification, Section 32 92 23

0007BWReplace existing Top Soil with 100mm thk. Top Soil100SMWW
0007BXInstall 100mm thk. Top Soil100SMWW
0007BYInstall Spot Sodding720SMWW
0007BZInstall Strip Sodding100SMWW
0007CAInstall Solid Sodding1,440SMWW
Exterior Plants

DPW Guide Specification, Section 32 93 00

0007CBInstall Landscape Conc. Block50SMWW
0007CCRemoval of Tree10EAWW
0007CDPlant Tree (Excluding the price of the tree. Approx. 5 meters or less in height and 200mm diameter or less, Tree type is based on planting trees suggested in IPS)50EAWW
0008Utilities

(DPW Guide Specifications Division 33) Water Utility Distribution piping DPW Guide Specification, Section 33 11 00

0008AARemoval of Water Line & Plug, (up to 300mm Dia.) (Per LM)200LMWW
0008ABInstall 50mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008ACInstall 75mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008ADInstall 100mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008AEInstall 150mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008AFInstall 200mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008AGInstall 250mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008AHInstall 300mm dia AWWA C-900 150 PSI Water Pipe Line (Per LM)50LMWW
0008AJInstall 50mm dia. Gate valve & thrust block(Per EA)5EAWW
0008AKInstall 75mm dia. Gate valve & thrust block(Per EA)5EAWW
0008ALInstall 100mm dia. Gate valve & thrust block(Per EA)5EAWW
0008AMInstall 150mm dia. Gate valve & thrust block(Per EA)5EAWW
0008ANInstall 200mm dia. Gate valve & thrust block(Per EA)5EAWW
0008APInstall 250mm dia. Gate valve & thrust block(Per EA)5EAWW
0008AQInstall 300mm dia. Gate valve & thrust block(Per EA)5EAWW
0008ARInstall Gate Valve Box (Per EA)5EAWW
0008ASInstall Indicator Post (Per EA)5EAWW
0008ATInstall Fire Hydrant and Guard Post (Per EA)5EAWW
0008AUInstall 100mm bend & thrust block.(Per EA)5EAWW
0008AVInstall 150mm bend & thrust block.(Per EA)5EAWW
0008AWInstall 200mm bend & thrust block.(Per EA)5EAWW
0008AXInstall 250mm bend & thrust block.(Per EA)5EAWW
0008AYInstall 300mm bend & thrust block.(Per EA)5EAWW
0008AZInstall 100 mm dia. Tee & thrust block (Per EA)5EAWW
0008BAInstall 150 mm dia. Tee & thrust block (Per EA)5EAWW
0008BBInstall 200 mm dia. Tee & thrust block (Per EA)5EAWW
0008BCInstall 250 mm dia. Tee & thrust block (Per EA)5EAWW
0008BDInstall 300 mm dia. Tee & thrust block (Per EA)5EAWW
0008BEInstall Valve Box (1.5m x 2m x 2m Depth) w/Lockable Cover for Security (Per EA)5EAWW
0008BFInstall Valve Box (3m x 5m x 2m Depth) w/Lockable Cover for Security (Per EA)5EAWW
0008BGInstall check valve 50mm dia. w/fitting(Per EA)5EAWW
0008BHInstall check valve 100mm dia. w/fitting(Per EA)5EAWW
0008BJInstall check valve 150mm dia. w/fitting(Per EA)5EAWW
0008BKInstall Flow Meter 50mm dia & Pressure Gage (Per EA)5EAWW
0008BLInstall Flow Meter 100mm dia & Pressure Gage (Per EA)5EAWW
0008BMInstall Flow Meter 150mm dia & Pressure Gage (Per EA)5EAWW
0008BNInstall Gate valve 50mm dia. w/ Valve box(Per EA)5EAWW
Sanitary Sewerage

DPW Guide Specification, Section 33 33 00

0008BPRemoval of Sewer line & plug, various size ( Per LM )200LMWW
0008BQInstall Sewer Man Hole (Less than 1.8m Deep) (Per EA)10EAWW
0008BRInstall S.M.H. ( 1.8m - 2.4m Deep) (Per EA)10EAWW
0008BSInstall S.M.H. ( 2.4m - 3.0m Deep) (Per EA)10EAWW
0008BTInstall S.M.H. ( 3.0m - 3.6m Deep) (Per EA)10EAWW
0008BUInstall 100mm dia Surface Cleanout (Per EA)5EAWW
0008BVInstall 150mm dia Surface Cleanout (Per EA)5EAWW
0008BWInstall 200mm dia Surface Cleanout (Per EA)5EAWW
0008BXInstall 150mm dia VG-1 P.V.C Sewer Line & Fitting (PER LM)100LMWW
0008BYInstall 200mm dia VG-1 P.V.C Sewer Line & Fitting (PER LM)100LMWW
0008BZInstall 300mm dia VG-1 P.V.C Sewer Line & Fitting (PER LM)100LMWW
0008CAInstall Reinforced Concrete Encasement (PER LM) (100mm dia)100LMWW
0008CBInstall Reinforced Conc. Encasement (PER LM) (150mm dia)100LMWW
0008CCInstall Reinforced Conc. Encasement (PER LM) (200mm dia)100LMWW
0008CDInstall Reinforced Conc. Encasement (PER LM) (250mm dia)100LMWW
0008CEInstall Reinforced Conc. Encasement (PER LM) (300mm dia)100LMWW
0008CFInstall Reinforced Conc. Encasement (PER LM) (350mm dia)100LMWW
Storm Drainage Utilities

DPW Guide Specification, Section 33 40 00

0008CGRemoval of Reinforced Concrete Pipe, Various Size (PER LM)100LMWW
0008CHInstall Surface inlet or Catch Basin (up to 1.5m) (Per EA)5EAWW
0008CJInstall 300mm dia Reinforced Concrete Pipe (PER LM)10LMWW
0008CKInstall 450mm dia R.C.P (PER LM)10LMWW
0008CLInstall 600mm dia R.C.P (PER LM)10LMWW
0008CMInstall 1.2m W x 1.2m L x 1.6m D Conc. Manhole include Cast Iron Frame and Cover (Per EA)5EAWW
0008CNInstall Conc. Ditch (300mm W, Various Height) (PER LM)100LMWW
0008CPInstall Conc. Ditch (450mm W, Various Height) (PER LM)100LMWW
0008CQInstall Conc. Ditch (600mm W, Various Height) (PER LM)100LMWW
0008CRInstall Conc. Ditch Cover (300mm W) (Per EA) (PER LM)100LMWW
0008CSInstall Conc. Ditch Cover (450mm W) (Per EA) (PER LM)100LMWW
0008CTInstall STL Grating Cover, 20 ton Load (300mm W) (PER LM)50LMWW
0008CUInstall STL Grating Cover, 20 ton Load (450mm W) (PER LM)50LMWW
0008CVInstall STL Grating Cover, 20 ton Load (600mm W) (PER LM)50LMWW
0008CWInstall Conc. Head Wall for 450mm dia Pipe (Per EA)2EAWW
0008CXInstall Conc. Head Wall for 600mm dia Pipe (Per EA)2EAWW
0008CYInstall Turf Swale (Per SM)100SMWW
0008CZInstall Riprap Apron (Per SM)100SMWW
0009Transportation

(DPW Guide Specifications Division 34) Vehicle Guardrail DPW Guide Specification, Section 34 71 13. 26 31

0009AAInstall metal post guardrail & spacer block50LMWW
0009ABInstall Metal post guardrail w/o spacer block50LMWW
0009ACInstall conc. post guard rail & spacer block50LMWW
0009ADInstall conc. post guard rail w/o spacer block50LMWW
0010Survey (DPW Guide Specifications Section : N/A )
0010AAGeneral Area Survey (100m x 100m, 1Day)10MDWW- 0
0010ABSlope and Restricted Area Survey (100m x 100m, 1Day)10MDWW
0010ACDigitizing and topographic design - TYP. Contour span (20mm)4MDWW
0011Architectural Work
0011Masonry, Removal work

DPW Guide Specifications, Section 04 20 00

0011AARemove CMU wall, 100mm-190mm thick w/re-bars & W.W.F30CMWW
0011ABRemove lintel or sills for windows, doors and all openings15LMWW
0011ACRemove precast coping on top of wall20LMWW
Misc. Metal Fabrication, Removal work

DPW Guide Specifications, Section 05 50 13

0011ADRemove Stainless Steel Pipe Column, 25.4mm dia. Through 76.3mm dia20LMWW
0011AERemove Stainless Steel Pipe Column, 100mm dia. Through 125mm dia20LMWW
Metal Stairs, Removal work

DPW Guide Specifications, Section 05 51 00

0011AFRemove Stainless Steel Non-Slip on Stairway30LMWW
Metal railings, Removal work

DPW Guide Specifications, Section 05 52 00

0011AGRemove Guardrail and handrail with post, metal pipe30LMWW
Rough carpentry, Removal work

DPW Guide Specifications, Section 06 10 00

0011AHRemove 2Ply- Plywood Sheathing30SMWW
Finish carpentry, Removal work

DPW Guide Specifications, Section 06 20 00

0011AJRemove wood fascia board or soffit board with nailed50LMWW
0011AKRemove Wood Molding100LMWW
Mineral Fiber Blanket Insulation, Roof and Deck Insulation, Removal work

DPW Guide Specification, Section 07 21 16 and 07 22 00

0011ALRemove mineral fiber blanket insulation or rigid insulation in wall, ceiling and roof deck100SMWW
Exterior Insulation and Finish Systems, Removal work

DPW Guide Specification, Section 07 24 00

0011AMRemove Exterior Insulation and Finish System including metal lath EPS board etc. On Existing Wall500SMWW
Asphalt Shingles, Removal work

DPW Guide Specification, Section 07 31 13

0011ANRemove Shingle Roof With 2-Ply Asphalt Felt30SMWW
Roof Tiles, Removal work

DPW Guide Specification, Section 07 32 13

0011APRemove Korean Cement Roof Tile With 2-Ply Asphalt Felt, Wood Strip30SMWW
Metal wall panel, Removal work

DPW Guide Specification, Section 07 42 13

0011AQRemove Corrugated Iron Sheet Siding30SMWW
Ethylene Propylene Diene Monomer Roofing, Removal work

DPW Guide Specification, Section 07 53 23

0011ARRemove EPDM roofing with insulation, included seam tape, bonding adhesive and membrane flashings, lap sealant, edge treatment & EPDM sheet200SMWW
0011ASRemove rubber walk board on EPDM roofing sheet15EAWW
Flashing and sheet metal, Removal work

DPW Guide Specification, Section 07 60 00

0011ATRemove Metal Gutter or downspout with strap and hanger500LMWW
Steel doors and frames, Removal work

DPW Guide Specification, Section 08 11 13

0011AURemove All type of Single Steel Door without door frame6EAWW
0011AVRemove All type of Double Steel Door without door frame6EAWW
0011AWRemove All type of Single Steel Door With Frame, lockset, hinges, threshold, exit device and trim etc.6EAWW
0011AXRemove All type of Double Steel Door With Frame, lockset, hinges, threshold, exit device and trim etc.6EAWW
Aluminum doors and frames, Removal work

DPW Guide Specification, Section 08 11 16

0011AYRemove all type of Alum. Door including Manual operated Entrance door without Door Frame10SMWW
0011AZRemove All type of Alum. Door including Manual operated Entrance door With Door Frame, hinges, threshold, lockset, exit device and trim including fixed glasses etc.10SMWW
Wood doors, Removal work

DPW Guide Specification, Section 08 14 00

0011BARemove All type of wooden Single Door W/O Door Frame3EAWW
0011BBRemove All type of wooden Double Door W/O Door Frame3EAWW
0011BCRemove All type of Wooden Single Door With Frame, hinges, threshold, exit device and trim etc.3EAWW
0011BDRemove All type of Wooden Double Door With Frame, hinges, threshold, exit device and trim etc.3EAWW
Access door and panel, Removal work

DPW Guide Specification, Section 08 31 00

0011BERemove Ceiling Access Door with Frame3EAWW
Alum. sliding glass doors / Alum. Framed entrances, Removal work

Unified Facilities Guide Specification, Section 08 32 13 / 08 41 13

0011BFRemove All type of Alum. Auto Swing or Sliding Door With Door Frame, hinges, threshold, exit device, trim and fixed glasses, including Elec. Power and Fire alarm system disconnection etc.10SMWW
Metal rolling counter doors / Overhead coiling doors, Removal work

DPW Guide Specification, Section 08 33 13 / 08 33 23

0011BGRemove electrical powered metal rolling counter door or overhead coiling door with guide rail, insulated slot, motor operator, hand chain hoist, locking device, weather seal and wall mounted button control station etc.90SMWW
Aluminum windows, Removal work

DPW Guide Specification, Section 08 51 13

0011BHRemove Aluminum Window with Frame, trim and insect screen15SMWW
Door hardware, Removal work

DPW Guide Specification, Section 08 71 00

0011BJRemove Door hardware's(Exit device, Door check, Door stop, Threshold, weather-strip, Door Coordinator, Astragal, Kick plate, push plate, floor hinge and all type of lockset etc.)6EAWW
Gypsum board / Supports for plaster and gypsum board, Removal work

DPW Guide Specification, Section 09 22 00 / 09 29 00

0011BKRemove gypsum wall board1500SMWW
0011BLRemove gypsum ceiling board1500SMWW
0011BMRemove Metal or wood member Stud & runner 50mm-203mm W. 300mm~450mm O.C1000SMWW
0011BNRemove M-Bar type metal or wood ceiling suspension system1000SMWW
Ceramic tile, Quarry tile and paver tile, Removal work

DPW Guide Specification, Section 09 30 10

0011BPRemove Cement Plaster wall including Asphalt felt, metal lath etc.300SMWW
0011BQRemove Ceramic wall & floor Tile380SMWW
0011BRRemove Ceramic wall & floor Tile including setting bed1605SMWW
0011BSRemove Silicon sealants and caulking2100LMWW
Acoustical ceilings, Removal work

DPW Guide Specification, Section 09 51 00

0011BTRemove acoustical ceiling tile without frame3000SMWW
0011BURemove and re-install acoustical ceiling tile1000SMWW
0011BVRemove T-bar type metal suspended ceiling system3000SMWW
Resilient flooring, Removal work

DPW Guide Specification, Section 09 65 00

0011BWRemove vinyl cove base3000LMWW
0011BXRemove vinyl composition tile4200SMWW
0011BYRemove rubber tile2200SMWW
Carpet, Removal work

DPW Guide Specification, Section 09 68 00

0011BZRemove carpet or carpet tile with glue and felt1200SMWW
Wall Covering, Removal work

DPW Guide Specification, Section 09 72 00

0011CARemove Wallpaper100SMWW
Paints and Coatings, Removal work

DPW Guide Specification, Section 09 90 00

0011CBRemove existing paint for metal surface (By using hand & power tool machine)100SMWW
0011CCRemove existing paint for CMU or concrete surface (By using hand & power tool machine)100SMWW
0011CDRemove existing paint for wooden surface (By using hand & power tool machine)100SMWW
Toilet Accessories, Removal work

DPW Guide Specifications, Section 10 28 13

0011CERemove & re-install Toilet accessories (Lavatory faucet, Shower faucet, Towel bar, Mirror, Soap dish, Clotheshorse and Toilet tissue dispenser etc.)10EAWW
0011CFRemove and re-install Toilet Fixtures (Urinal, Water Closet, Lavatory with Cabinet including drainage system)10EAWW
Window Blind, Removal work

DPW Guide Specification, Section 12 21 00

0011CGRemove Blind, Vertical or venetian10SMWW
Manufactured Wood Case Casework and Countertops, Removal work

DPW Guide Specification, Section 12 32 00 & 12 36 00

0011CHRemove Kitchen Wall or Base Cabinet W/ Door and countertops(wall cabinet Depth 300-400mm X Height 640 - 770mm or base cabinet Depth 600-650mm X Height 900-1100mm)10LMWW
0011CJRemove and Reinstall Various Furniture Including Steel or Wooden Cabinets, Shelves, Book Cases, Office Furniture, Chairs, Refrigerators & Other Office Equipment's.1760CMWW
0012Masonry

DPW Guide Specifications, Section 04 20 00

0012AABlock-up window & other opening w/CMU wall, 100mm to 190mm thk.22SMWW
0012ABBlock-up window & other opening w/#24 gage corrugated iron sheet 100mm thk insulation wood frame and interior lining9SMWW
0012ACInstall CMU wall, 100mm-190mm thick w/re-bars176SMWW
0013Metal stairs

DPW Guide Specifications, Section 05 51 00

0013AAInstall stainless steel non-slip on stair22LMWW
0014Finish carpentry

DPW Guide Specifications, Section 06 10 00

0014AAInstall wood member with stud, furring, blocking & trim etc, at wall1082BFWW
0014ABInstall 18mm thick plywood sheathing88SMWW
Finish carpentry

DPW Guide Specifications, Section 06 20 00

0014ACInstall wood fascia board & nailed incl. painting, 25mm x 250mm13LMWW
0014ADInstall soffit board, trim & paint 12mm thick plywood9SMWW
0014AEInstall 25mm x 100mm wood base board1056LMWW
0014AFInstall chair rail, 100mm or 150mm oak molding88LMWW
0014AGInstall hardwood closet shelf, 600mm wide x 25mm thick Incl. stain & vanish finish1LMWW
0015Fluid-Applied Waterproofing

DPW Guide Specification, Section 07 14 00

0015AAInstall existing waterproofing materials and pressure wash roof surface, seal exposed cracks and crevices, apply concrete sealer, flash transition point, roof penetrations & install acrylic fluid applied waterproofing on existing concrete flat roof.88SMWW
Mineral Fiber Blanket Insulation/Roof and Deck Insulation

DPW Guide Specification, Section 07 21 16/07 22 00

0015ABInstall insulation w/aluminum foil jacket, in wall 75mm thick1144SMWW
Exterior Insulation and Finish System

DPW Guide Specification, Section 07 24 00

0015ACInstall exterior insulation and finish systems on concrete or CMU or metal wall including metal lath13SMWW
Asphalt Shingles

DPW Guide Specification, Section 07 31 13

0015ADInstall asphalt shingle and 1-ply rubberized waterproofing membrane sheet880SMWW
Roof Tiles

DPW Guide Specification, Section 07 32 13

0015AEInstall Korean cement roof tile, factory color finish size: 12 mm x 400 mm x 350mm with 2-ply rubberized waterproofing membrane sheet underlayment & treated battens88SMWW
Metal Roof/Metal Wall Panels

DPW Guide Specification, Section 07 41 13/07 42 13

0015AFInstall #24 gauge galvanized corrugated metal roof & painting35SMWW
0015AGInstall #24 gage corrugated sheet metal siding and painting18SMWW
0015AHInstall #26 gage sheet metal lining on the wall, ceiling35SMWW
Flashing and Sheet Metal

DPW Guide Specification, Section 07 60 00

0015AJInstall #24 gauge 150mm-200mm wide sheet metal rain gutter & hanger incl. painting114LMWW
0015AKInstall #24 gauge 100mm-150mm dia. sheet metal downspout & strap incl. Painting88LMWW
0015ALInstall basket strainer, 100mm dia. ~ 150mm dia.18EAWW
0015AMInstall #24 gauge galvanized sheet metal flashing incl. painting for valley flashing, drip edge, window, door, corner, smoke stack, duct and etc.88SMWW
0016Steel door and frames

DPW Guide Specification, Section 08 11 13

0016AAInstall steel flush single door with steel door frame , 900 mm X 2,150 mm, 44.5 mm thick1EAWW
0016ABInstall steel flush 180mm X 670mm vision glass insulated single door with steel door frame , 900 mm X 2,150 mm, 44.5 mm thick1EAWW
0016ACInstall steel flush louvered insulated single door with steel door frame , 900 mm X 2,150 mm, 44.5 mm thick1EAWW
0016ADInstall steel flush insulated double door with steel door frame , 1,800 mm X 2,150 mm, 44.5 mm thick1EAWW
0016AEInstall steel flush insulated louvered double door with steel door frame , 1,800 mm X 2,150 mm, 44.5 mm thick1EAWW
0016AFInstall steel flush insulated 180mm X 670mm vision glasses double doors with steel door frame , 1,800 mm X 2,150 mm, 44.5 mm thick1EAWW
Aluminum door and frames

DPW Guide Specification, Section 08 11 16

0016AGInstall aluminum screen single door, 900mm x 2150mm132EAWW
Wood door

DPW Guide Specification, Section 08 14 00

0016AHInstall wood flush hollow core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick1EAWW
0016AJInstall wood flush solid core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick1EAWW
0016AKInstall wood flush 180mm X 670mm vision glass solid core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick1EAWW
0016ALInstall wood flush louvered solid core single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick1EAWW
0016AMInstall wood flush hollow core dutch single door with steel door frame , 900 mm X 2,150 mm, 35 mm thick1EAWW
Access door and panels

DPW Guide Specification, Section 08 31 00

0016ANInstall ceiling access metal door w/metal frame swing up model, 450mm x 450mm13EAWW
Forced entry resistant components

DPW Guide Specification, Section 08 34 01

0016APInstall 90 minute fire rated steel flush insulated single door with steel door frame, 900 mm X 2,150 mm, 44.5 mm thick1EAWW
0016AQInstall 90 minute fire rated wood flush insulated single door with steel door frame, 900 mm X 2,150 mm, 44.5 mm thick1EAWW
0016ARInstall 45 minute fire rated wood flush insulated single door with steel door frame, 900 mm X 2,150 mm, 44.5 mm thick1EAWW
Aluminum windows

DPW Guide Specification, Section 08 51 13

0016ASInstall aluminum sash sliding window & aluminum frame, insect screen & window latch 6mm glass + 12mm air space + 6mm laminated inner glass)176SMWW
0016ATInstall aluminum sash sliding window & aluminum frame 6mm thick laminated glass5SMWW
0016AUInstall aluminum framed insect screen26SMWW
0016AVInstall only screen for door & window6SMWW
0016AWInstall fixed aluminum window & aluminum frame1SMWW
0016AXInstall single hung window & aluminum frame1SMWW
0016AYInstall awning with Fixed window & aluminum frame1SMWW
0016AZInstall project window & aluminum frame1SMWW
0016BAInstall 1,200x1,200 Dual action aluminum window(Turn and tilt) & aluminum frame1SMWW
Door hardware

DPW Guide Specification, Section 08 71 00

0016BBInstall exit device, type 3 or 10, F-05/08 (ANSI/BHMA A156.3)5EAWW
0016BCInstall exit device, type 2, F-01 (ANSI/BHMA A156.3)4EAWW
0016BDInstall mortise lockset, F-02, F-04, F-05, F-07, F-08 or F-13 (ANSI/BHMA A156.13)40EAWW
0016BEInstall bored type lockset, F-82 or F-86 (ANSI/BHMA A156.2)130EAWW
0016BFInstall hinge butt, 4-1/2" x 4-1/2", A2111 or A5111 (ANSI/BHMA A156.1)458EAWW
0016BGInstall hinge butt, 4-1/2" x 4-1/2", A8111 (ANSI/BHMA A156.1)12EAWW
0016BHInstall aluminum weather strip for door119LMWW
0016BJInstall astragal for door11LMWW
0016BKInstall aluminum threshold, 100mm-150mm wide106LMWW
0016BLInstall door stopper and holder, L01361, L01371, L02141, L01381, L02121, L01241 & etc. (ANSI/BHMA A156.16)97EAWW
0016BMInstall foot bolt, 150mm long1EAWW
0016BNInstall door closer, C02021, C02011 (ANSI/BHMA A156.4)1EAWW
0016BPInstall push plate, J304 (ANSI/BHMA A156.16)18EAWW
0016BQInstall pull plate, J407 (ANSI/BHMA A156.16)18EAWW
0016BRInstall kick plate, J102 (ANSI/BHMA A156.16)55EAWW
0016BSInstall door viewer, 180 degree angle of view. L03171 (ANSI/BHMA A156.16)11EAWW
Glazing

DPW Guide Specification, Section 08 81 00

0016BTInstall 5mm thick polycarbonate sheet with caulking
(DPW Guide Specifications Section 08 81 00 )4SMWW
0017Supports for plaster and gypsum board

DPW Guide Specification, Section 09 22 00

0017AAInstall metal stud/runner for wall, 90mm -150mm wide, 300mm - 450mm on center600SMWW
0017ABInstall M-Bar furring for wall 22mm D x 35mm W9LMWW
0017ACInstall suspended ceiling metal frame for gypsum board484SMWW
0017ADInstall suspended ceiling metal frame for acoustical tile484SMWW
0017AEInstall metal casing bead44LMWW
Lath

DPW Guide Specification, Section 09 22 36

0017AFInstall plaster wall w/15# asphalt felt , metal lath (1.8kg per square meter) and 25mm thick cement plaster finish774SMWW
Gypsum board

DPW Guide Specification, Section 09 29 00

0017AGInstall wall board with 12.5mm thick gypsum board including joint taping & compound, regular type1144SMWW
0017AHInstall wall board with 15mm thick gypsum board incl. joint taping & compound, type "X" (Special fire resistant )70SMWW
0017AJInstall wall board with 12.5mm thick gypsum board incl. joint taping & compound, water resistant type282SMWW
0017AKInstall ceiling board with 12.5mm thick gypsum board incl. joint taping & compound475SMWW
0017ALInstall ceiling board with 15mm thick gypsum board incl. joint taping & compound, type "X" (Special fire resistant)44SMWW
0017AMInstall ceiling board with 12.5mm thick gypsum board incl. joint taping & compound, water resistant type229SMWW
Ceramic, quarry and glass tiling

DPW Guide Specification, Section 09 30 10

0017ANInstall ceramic mosaic floor tile or ceramic floor tile290SMWW
0017APInstall ceramic wall tile incl. accessories (trim & corner)792SMWW
Acoustical ceiling

DPW Guide Specification, Section 09 50 00

0017AQInstall 15mm thick acoustical ceiling tile1500SMWW
Resilient flooring

DPW Guide Specification, Section 09 65 00

0017ARInstall vinyl composition tile 300mm x 300mm x 3mm thick1056SMWW
0017ASInstall vinyl composition tile, 450mm x 450mm x 3mm thick1408SMWW
0017ATInstall rubber tile, 500mmx500mmx4mm thick352SMWW
0017AUInstall rubber stair tread with integrated riser, 480mm wide x 5mm thick38SMWW
0017AVInstall vinyl cove base, 100mm to 150mm high1760LMWW
Carpeting

DPW Guide Specification, Section 09 68 00

0017AWInstall Carpet, Nylon Pattern Cut/Loop Incl. Accessories475SMWW
0017AXInstall nylon carpet with level-loop, multilevel loop, cut and loop incl. accessories739SMWW
0017AYInstall carpet tile, loop, incl. accessories 500mm x 500mm x 9.5mm thick53SMWW
Rigid gird access flooring

DPW Guide Specification, Section 09 69 13

0017AZInstall raised floor system, 600 mm X 600 mm including die cast panel, stringer, pedestals, non - conductive tile and accessories50SMWW
Wall covering

DPW Guide Specification, Section 09 72 00

0017BAInstall wall paper (fire retardant type) Class A flame spread rating of 0-25 and smoke development rating of 0-50 when tested in accordance with ASTM E 84.211SMWW
0017BBInstall caulking for bathroom & kitchen546LMWW
Painting

DPW Guide Specification, Section 09 90 00

0017BCPaint, interior , 2-coats20000SMWW
0017BDPaint, interior oil modified clear urethane, stain, 3-coats26SMWW
0017BEPaint, exterior alkyd enamel 2-coats1056SMWW
0017BFPaint on metal surface, aluminum paint, 2 coats9SMWW
0017BGPaint, galvanized metal primer, 1 coat88SMWW
0017BHPaint, interior primer sealer, 1 coat440SMWW
0017BJPaint on concrete floor, epoxy paint, 2 coats264SMWW
0017BKPaint, stain wood floor, natural finish, 3 coats9SMWW
0017BLPaint for exterior insulation and finish system70SMWW
0017BMInstall hardener for concrete floor slab50SMWW
0018Toilet compartments

DPW Guide Specifications Sections 10 21 13

0018AAInstall metal toilet partition & door40EAWW
0018ABInstall metal urinal baffle18EAWW
0018ACInstall shower bench, 300mm wide4LMWW
Toilet accessories

DPW Guide Specifications Sections 10 28 13

0018ADInstall stainless steel (SST) shower curtain rod, w/curtain 25mm dia x 900mm - 1200mm lg.40EAWW
0018AEInstall SST robe hook26EAWW
0018AFInstall soap dish (stainless or ceramic)44EAWW
0018AGInstall metal framed glass mirror, 450mm x 600mm high.35EAWW
0018AHInstall metal framed tilting glass mirror, 400mm x 750mm high.18EAWW
0018AJInstall toilet tissue dispenser38EAWW
0018AKInstall paper towel dispenser13EAWW
0018ALInstall liquid soap dispenser26EAWW
0018AMInstall #18 gauge heavy duty SST shelf incl. brackets & supports22EAWW
0018ANInstall #20 gauge light duty SST shelf incl. brackets & supports22EAWW
0018APInstall SST towel bar 19mm dia. X 500mm lg., 1 or 2 hanger23EAWW
0018AQInstall vanity cabinet, 700 mm W x 490 mm D x 760 mm H w/marble top35EAWW
0018ARInstall medicine cabinet, 470 mm x 870 mm H9EAWW
Fire extinguishers

DPW Guide Specifications Sections 10 44 16

0018ASInstall stainless steel fire extinguisher cabinet below 2 hour rated.10EAWW
0019Window blinds

DPW Guide Specification, Section 12 21 00

0019AAInstall horizontal blind, 25mm aluminum slats incl. head channel, bracket and accessories145SMWW
0019ABInstall vertical blind, 89mm aluminum or cloth strips incl. bracket and accessories62SMWW
Commercial kitchen casework/Countertops

DPW Guide Specification, Section 12 35 39/12 36 00

0019ACInstall kitchen wall cabinet with door 640mm~770mm H x 300 - 400mm D X 1,000mm W30L/MWW
0019ADInstall Kitchen Hood wall cabinet with door 600mm W x 520 - 700mm H x 300 - 400mm D10EAWW
0019AEInstall Kitchen Hood wall cabinet with door, 900mm -1,100mm W x 520 - 700mm H x 300 - 400mm D10EAWW
0019AFInstall kitchen base cabinet with door Incl. Artificial Marble Counter Top, Sink Faucet & Single bowl sink or double bowl sink, 800mm~920mm H x 600mm - 650mm D x 1,000mm W10EAWW
0019AGInstall kitchen base cabinet with door Incl. Artificial Marble Counter Top, Sink Faucet & Single bowl sink or double bowl sink 900mm~1,200mm W x 800mm - 920 H x 600mm - 650mm D10EAWW
0019AHInstall kitchen counter top artificial marble counter top with back splash20LMWW
0020Mechanical Work ( Remove )

(DPW Guide Spec. Sec. 02 41 00)

0020AARemove packaged liquid chiller, air cooled or water cooled condenser type, all standard accessories, cooling capacity: any size1EAWW
0020ABRemove air handling unit, all type, cooling/heating coil, capacity: any size1EAWW
0020ACRemove air cooled condensing unit, any size1EAWW
0020ADRemove cooling tower, any size1EAWW
0020AERemove package air conditioning unit,
stand-alone indoor unit, air cooled condensing outdoor unit with OA duct & piping system, cooling coil & heat pump or electric heating coil, capacity : any size1EAWW
0020AFRemove hot water heating boiler or domestic hot water heater, capacity : any size2EAWW
0020AGRemove expansion tank, bladder or diaphragm type, capacity : any size1EAWW
0020AHRemove unit heater, horizontal or vertical type, any capacity1EAWW
0020AJRemove finned tube radiator with non-electric control valve, any capacity4EAWW
0020AKRemove smoke stack with barometric damper, any size1SETWW
0020ALRemove pump, base mounted end suction or in-line type, capacity : any size1EAWW
0020AMRemove all type/size of valve & fitting (gate valve, glove valve or balancing cock, strainer, check valve, air separator, flexible connection & etc.)383EAWW
0020ANRemove steel pipe or copper, including all support & fittings except insulation, any size2755MWW
0020APRemove pipe insulation, flexible cellular(Armaflex) or glass wool, including adhesive & tape cover, any size2817MWW
0020AQRemove roof or wall ventilator, any type/capacity3EAWW
0020ARRemove bathroom exhaust fan with grille & backdraft damper35EAWW
0020ASRemove duct accessories (diffuser, grille, register, louver, volume damper, fire/smoke damper, fire/smoke louver or turning vane)23EAWW
0020ATRemove all air duct11M2WW
0020AURemove duct insulation, flexible cellular or glass wool11M2WW
0020AVRemove sanitary ware (water closet, urinal, lavatory, service sink, kitchen sink & etc. with accessories)86SETWW
0020AWRemove shower, wall mounted type, with lever & head38SETWW
0020AXRemove galvanized steel vent pipe with fittings & support192MWW
0020AYRemove cast iron pipe, any size158MWW
0020AZRemove sprinkler head, pendent or upright, chrome, fusible link type2EAWW
0020BARemove sprinkler pipe, including fittings & support, black steel schedule #40, size : any size8MWW
0020BBRemove all type sensor (temperature, humidity & other detectors)45EAWW
0020BCRemove inside equipment concrete pad, 50mm thk.2SMWW
0020BDRemove outside equipment concrete pad, 300mm thk.5SMWW
0020BERemove fan coil unit, floor mounted or ceiling mounted type, any size48EAWW
Mechanical Work ( Install )
0021Fire suppression

(DPW Guide Spec. Sec. 21 13 13.00 10)

0021AA*Install sprinkler head, pendent or upright, quick response, chrome, fusible link type36EAWW
0021ABInstall sprinkler pipe, including fittings, supports, black steel schedule #40,
size 25mm104MWW
0021ACDitto, 32 mm20MWW
0021ADDitto, 40 mm1MWW
0021AEDitto, 50 mm20MWW
0021AFDitto, 100 mm53MWW
0022Plumbing, general purpose

(DPW Guide Spec. Sec. 22 00 00)

0022AA*Install water closet, flush tank type,1 piece, vitreous china with siphon jet
flushing valve & accessories, (American std. 2403.128-1.28 gpf)1SETWW
0022AB*Install water closet, flush valve type, vitreous china with siphon jet
flushing valve & accessories, except flush valve (American std. 2403.128-1.28 gpf)7SETWW
0022AC*Install urinal, flush valve type, wall hung, vitreous china, except flush valve (American std. 6590.001-0.5 gpf)4SETWW
0022AD*Install lavatory, counter top, single lever, vitreous china, accessories, 0.5 gpf8SETWW
0022AE*Install lavatory, 2 handle lever, vitreous china, accessories, for handicapped (American std. 9141.011.020 & 6531.145)1SETWW
0022AF*Install service sink, enameled cast iron with accessories (American std. 2696.102 & 7295.252)1SETWW
0022AG*Install kitchen sink, double bowl, faucet, accessories, 33" x 21"1SETWW
0022AH*Install kitchen sink, single bowl, accessories, 33" x 19" (American std. 14SB331900 & 6409.180)1SETWW
0022AJ*Install shower, wall mounted, single lever, head (American std. T508.507)1SETWW
0022AK*Install toilet flush valve, manual type (American std. 6047.122.002)1SETWW
0022AL*Install toilet flush valve, sensor type (American std. 606B721)1SETWW
0022AM*Install electric water cooler, including piping & accessories1SETWW
0022AN*Install backflow preventer with pressure reducing valve, bronze body, 20 mm dia.1EAWW
0022AP*Install domestic gas burner type hot water heater, 30,000 kcal/h or under
(ΔT 100 ℉, 115 GPH)1EAWW
0022AQ*Ditto, 50,000 kcal/h (192GPH)1EAWW
0022AR*Ditto, 65,000 kcal/h (250 GPH)1EAWW
0022AS*Ditto, 90,000 kcal/h (360 GPH)1EAWW
0022AT*Install electric domestic water heater, 100 lit., 1.6 kW1EAWW
0022AU*Ditto, 450 lit., 4.5 kW2EAWW
0022AV*Ditto, 1,000 LG, 10 kW1EAWW
0022AWInstall galvanized steel pipe, schedule#40 with fitting & support, for sewer vent pipe, 32mm dia.23MWW
0022AXDitto, 40mm dia.14MWW
0022AYDitto, 50mm dia.20MWW
0022AZDitto, 65mm dia.23MWW
0022BADitto, 80mm dia.4MWW
0022BBDitto, 100mm dia.4MWW
0022BCInstall cast iron soil pipe, hub type, 50 mm dia.39MWW
0022BDDitto, 75 mm dia.6MWW
0022BEDitto, 100 mm dia.24MWW
0022BFDitto, 125 mm dia.1MWW
0022BGInstall floor cleanout with 45 deg. Bend & extension pipe, with Y-branch, 100 mm dia.3EAWW
0022BHDitto, 75 mm dia.1EAWW
0022BJDitto, 50 mm dia.1EAWW
0022BKInstall floor drain, with P-trap, 50 mm dia.8EAWW
0022BLDitto, 100 mm dia.1EAWW
0022BMInstall faucet/ hose bibb, 15 mm dia.1EAWW
0022BNInstall water hammer arrester , PDI unit "A" type9EAWW
0022BPDitto, "B" type1EAWW
0022BQDitto, "C" type3EAWW
0022BR*Install sump/submersible pump, cast iron, single stage, vertical with control panel, water level switch and pump guide, below or equal 25 gpm / 1 HP1EAWW
0022BS*Ditto, 75 gpm, 1-1/2 HP1EAWW
0022BT*Ditto, 100 gpm, 2 HP1EAWW
0022BU*Ditto, 150 gpm, 3 HP1EAWW
0022BV*Ditto, 200 gpm, 5 HP1EAWW
0022BW*Ditto, 300 gpm, 10 HP1EAWW
0022BX*Ditto, 500 gpm, 15 HP1EAWW
0022BY*Ditto, 800 gpm, 20 HP1EAWW
0022BZ*Install sump/submersible pump, cast iron, single stage, explosion proof type vertical with control panel, water level switch and pump guide, 25 gpm and less1EAWW
0022CA*Ditto, 75 gpm1EAWW
0022CB*Ditto, 100 gpm1EAWW
0022CC*Ditto, 150 gpm1EAWW
0022CD*Ditto, 200 gpm1EAWW
0022CE*Ditto, 300 gpm1EAWW
0022CF*Ditto, 500 gpm1EAWW
0022CG*Ditto, 800 gpm1EAWW
0023Air supply, distribution, ventilation & exhaust system

(DPW Guide Spec. Sec. 23 00 00)

0023AA*Install air handling unit, all type, cooling/heating coil, 3,400 CMH (2,000 CFM)1EAWW
0023AB*Ditto, 8,500 CMH (5,000 CFM)1EAWW
0023AC*Ditto, 17,000 CMH (10,000 CFM)1EAWW
0023AD*Ditto, 25,500 CMH (15,000 CFM)1EAWW
0023AE*Ditto, 34,000 CMH (20,000 CFM)1EAWW
0023AF*Ditto, 51,000 CMH (30,000 CFM)1EAWW
0023AG*VAV or CAV terminal w/ hot water reheat, damper, actuator, thermostat, control valve & controller, 1,000 CFM or under1EAWW
0023AH*Ditto, 1,500 CFM or under1EAWW
0023AJ*Ditto, 3,000 CFM or under1EAWW
0023AK*Install fan coil unit, floor mounted, 3 row coil, manual air vent, 3 speed switch, UL motor, washable filter, fresh air intake grille, 400 CFM10EAWW
0023AL*Ditto, 600 CFM11EAWW
0023AM*Ditto, 800 CFM2EAWW
0023AN*Ditto, 1,200 CFM1EAWW
0023AP*Install fan coil unit, above ceiling mounted, UL motor, 400 CFM1EAWW
0023AQ*Ditto, 600 CFM1EAWW
0023AR*Ditto, 800 CFM1EAWW
0023AS*Ditto, 1,200 CFM1EAWW
0023AT*Install liquid filter dryer for refrigeration line5EAWW
0023AU*Install sight glass for refrigeration line5EAWW
0023AV*Install roof ventilator, direct or belt driven, 815 CFM under, 1/4" SP1EAWW
0023AW*Ditto, direct driven, 2050 CFM under, 1/4" SP1EAWW
0023AX*Ditto, belt driven, 1650 CFM under, 1/4" SP1EAWW
0023AY*Ditto, belt driven, 2750 CFM under, 1/4" SP1EAWW
0023AZ*Ditto, belt driven, 3500 CFM under, 1/4" SP1EAWW
0023BA*Install wall ventilator, direct or belt driven, 1320 CFM, 1/4 HP3EAWW
0023BB*Ditto, direct driven, 1983 CFM, 1/4 HP1EAWW
0023BC*Ditto, direct driven, 2900 CFM, 1/2 HP1EAWW
0023BD*Install utility fan, centrifugal, V-belt driven, pedestal, 2,000 CFM, 1 HP, 1/4" SP or under1EAWW
0023BE*Ditto, 3,600 CFM, 3/4 HP or under1EAWW
0023BF*Ditto, 4,800 CFM, 1 HP or under1EAWW
0023BG*Ditto, 15,000 CFM, 5 HP or under1EAWW
0023BH*Ditto, 20,000 CFM, 7.5 HP or under1EAWW
0023BJ*Install ceiling fan, right angle, extra quiet, 0.1" SP, 385 CFM1EAWW
0023BK*Ditto, 855 CFM1EAWW
0023BL*Install bathroom exhaust fan, grille, backdraft damper, 260 CFM1EAWW
0023BMInstall paddle blade ceiling fan, 52" blade, 3~5ea bade, fan cap.: 25,500 CFM, 1/8 HP1EAWW
0023BNInstall grille or louver or volume damper or turning vane, 300mm x 300mm or under1EAWW
0023BPDitto, 400 x 400 or under1EAWW
0023BQDitto, 500 x 500 or under1EAWW
0023BRDitto, 600 x 600 or under3EAWW
0023BSDitto, 700 x 700 or under8EAWW
0023BTDitto, 800 x 800 or under1EAWW
0023BUDitto, 900 x 900 or under1EAWW
0023BVDitto, 1000 x 1000 or under2EAWW
0023BWInstall register or backdraft damper, 300mm x 300mm or under1EAWW
0023BXDitto, 400 x 400 or under1EAWW
0023BYDitto, 500 x 500 or under1EAWW
0023BZDitto, 600 x 600 or under1EAWW
0023CADitto, 700 x 700 or under1EAWW
0023CBDitto, 800 x 800 or under1EAWW
0023CCDitto, 900 x 900 or under1EAWW
0023CDDitto, 1000 x 1000 or under1EAWW
0023CEInstall ceiling diffuser, round or square type w/damper, 200 mm neck dia. or under, aluminum4EAWW
0023CFDitto, 250 mm dia.1EAWW
0023CGInstall air duct, 0.5mm thk.(#26GA), without insulation61M2WW
0023CHInstall air duct, 0.6mm thk.(#24GA), without insulation74M2WW
0023CJInstall air duct, 0.8mm thk.(#22GA), without insulation28M2WW
0023CKInstall air duct, 1mm thk.(#20GA), without insulation1M2WW
0023CLInstall air duct, 1mm thk.(#16GA), without insulation1M2WW
0023CMInstall residential type range hood, 30" W, 2-speed, 210 CFM1EAWW
0023CNInstall insulated flexible duct for diffuser connection, 150 mm dia., 3m LG1EAWW
0023CPDitto, 300 mm dia., 3m LG1EAWW
0023CQInstall dryer vent kit, flexible hose/duct, weather cap1EAWW
Thermal insulation for mechanical system

(DPW Guide Spec. Sec. 23 07 00)

0023CRInstall pipe insulation, flexible elastomeric cellular(Armaflex) or glass wool, 40mm thk.. including adhesive & tape cover, 15 mm dia.194MWW
0023CSDitto, 20mm dia.86MWW
0023CTDitto, 25mm dia.97MWW
0023CUDitto, 32mm dia.12MWW
0023CVDitto, 40mm dia.27MWW
0023CWDitto, 50mm dia.54MWW
0023CXDitto, 50 mm thk., 65mm dia.41MWW
0023CYDitto, 50 mm thk., 80mm dia.1MWW
0023CZDitto, 50 mm thk., 100mm dia.1MWW
0023DADitto, 50 mm thk., 125mm dia.1MWW
0023DBDitto, 50 mm thk., 200mm dia.1MWW
0023DCInstall duct insulation, glass wool or flexible elastomeric cellular, 50 mm thk.162M2WW
0023DDInstall aluminum jacket on insulation, 50 mm dia. pipe or under50MWW
0023DEDitto, 150 mm dia. pipe or under50MWW
Direct digital control system for HVAC

(DPW Guide Spec. Sec. 23 09 23.01)

0023DFInstall LonWorks translator on existing equipment10EAWW
0023DGInstall new DDC program on existing CPU, multi-user, GUI, report output & historical data record function, included emergency back up/restoration disk or movable storage, MFR: Johnson Control, METASYS or approved equal2EAWW
0023DHRegister control point on new DDC program (300 CP or below),
1ea per Control Point(PC).200CPWW
0023DJRegister control point on new DDC program (above 300 CP), 1ea per CP.400CPWW
0023DKTest and inspect DDC communication, 1ea per DDC.50DDCWW
0023DLTest and inspect control point, 1ea per CP.400CPWW
Heating boiler

(DPW Guide Spec. Sec. 23 52 00)

0023DM*Install hot water heating boiler, 30,000 kcal/h (119,000 BTU/h), gas burner, steel body1EAWW
0023DN*Ditto, 50,000 kcal/h (200,000 BTU/h)1EAWW
0023DP*Ditto, 70,000 kcal/h (280,000 BTU/h)1EAWW
0023DQ*Ditto, 100,000 kcal/h (400,000 BTU/h)1EAWW
0023DR*Ditto, 131,000 kcal/h (525,000 BTU/h)1EAWW
0023DS*Ditto, 183,000 kcal/h (735,000 BTU/h)1EAWW
0023DT*Ditto, 262,000 kcal/h (1,050,000 BTU/h)1EAWW