H1-Revised_Drawing_for_AMENDMENT.PDF
PDF 13 MB Posted
- Attached to
- Repair Gym & Swiming Pool, Bldg# 151 & 158, K-16
- Solicitation number
- W91QVN18R0260
About this file
Revised drawing
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A21_W91QVN18R0260_Amendment_01.pdf | ||
| H1_188985_REPR-GYM-FAC-INDR-POOL-K16-158-151_DWG.PDF | ||
| A21_W91QVN18R0260_RFP.pdf | ||
| A22_Submittal_Register.XLSX | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
188985
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, SM
1:100
01 01 T-1
SCHEDULE OF DRAWINGS
RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.
1 OF 1T - 1
RING NO.
M - 1
M - 2
M - 3
MECHANICAL
ELECTRICAL
DESCRIPTION OF DRAWINGS
TITLE SHEET
DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS
M - 4
M - 5
M - 6
E - 1
E - 2
E - 3
E - 4
E - 5
E - 6
M - 8
M - 9
M - 10
M - 11
M - 12
M - 13
M - 14
M - 15
M - 16
M - 17
M - 18
LEGEND, GENERAL NOTES AND SCOPE OF WORKS3529 OF
TITLE SHEET
PWO. NO. 188985, K-16
ARCHITECTURAL
A - 1
A - 2
A - 3
2 OF
3 OF
A - 4 4 OF
1 OF 35 EXISTING/REMOVAL FLOOR PLAN AND GENERAL NOTES
NEW PROPOSED FLOOR PLAN AND SCOPE OF WORK
M - 7
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
A - 5
A - 6
A - 7
A - 8
A - 9
A - 1011
5 OF
6 OF
7 OF
8 OF
9 OF
10 OF
11 OF
12 OF
13 OF
14 OF
15 OF
16 OF
17 OF
18 OF
19 OF
20 OF
21 OF
22 OF
23 OF
24 OF
25 OF
26 OF
27 OF
28 OF
INTERIOR & EXTERIOR FINISH SCHEDULE
MATERIAL & COLOR SCHEDULE AND GENERAL NOTE
ENLARGED PARTIAL PLANS AND TOILET ACCESSORIES SCHEDULE
ENLARGED PARTIAL PLANS AND TOILET ACCESSORIES SCHEDULE
DOOR & WINDOW DESCRIPTIONS AND NOTES
SECOND FLOOR ENLARGED PLAN AND DETAILS
MISC. DETAILS
SWIMMING POOL FLOOR PLAN, ELEVATION AND NOTES
GENERAL NOTES & SCOPE OF WORK
EQUIPMENT SCHEDULES - 1
EQUIPMENT SCHEDULES - 2
EXISTING AND REMOVAL PLAN
EXISTING/NEW H.V.A.C. PIPING PLAN
EXISTING/NEW H.V.A.C. COMPOSITE PLAN
NEW H.V.A.C. ENLARGED PARTIAL PLAN - SECTOR "A"
NEW H.V.A.C. ENLARGED PARTIAL PLAN - SECTOR "B"
NEW H.V.A.C. ENLARGED PARTIAL PLAN - SECTOR "C"
EXISTING/NEW PLUMBING COMPOSITE PLAN
EXISTING/NEW DOMESTIC WATER PIPING ENLARGED PARTIAL PLAN-SECTOR "A"
EXISTING/NEW DOMESTIC WATER PIPING ENLARGED PARTIAL PLAN-SECTOR "B"
EXISTING/NEW SEWER & VENT PIPING ENLARGED PARTIAL PLAN - SECTOR"A"
EXISTING/NEW SEWER & VENT PIPING ENLARGED PARTIAL PLAN - SECTOR"B"
CONTROLS - 1
CONTROLS - 2
DETAILS - 2
DETAILS - 1
30 OF
31 OF
32 OF
33 OF
34 OF
REPAIR AND MAINTENANCE WORK
NEW CONSTRUCTION WORK
ARCHITECTURAL
A - 1
A - 2
A - 3
2 OF
3 OF
A - 4 4 OF
A - 5
A - 6
A - 7
5 OF
6 OF
7 OF
M - 1
M - 2
M - 3
MECHANICAL
GENERAL NOTES & SCOPE OF WORK
EQUIPMENT SCHEDULES
HEAT PUMP, EXHAUST FAN WITH DUCTS AND DRAIN SYSTEM PLAN
ELECTRICAL
E - 1 LEGEND, GENERAL NOTES AND SCOPE OF WORKS
DOOR DESCRIPTIONS
35 OF36 E - 7
LIGHTING PLAN
LIGHTING FIXTURE DETAILS
POWER PLAN
FIRE ALARM PLAN
H.V.A.C. POWER PLAN (1)
H.V.A.C. POWER PLAN (2)
8 OF
9 OF
10 OF
11 OF
FLOOR PLAN, ELEVATIONS, FINISH SCHEDULE AND SCOPE OF WORK
TYPICAL CROSS SECTION AND GENERAL NOTES
TYPICAL WALL SECTIONS
TRUSS DETAILS
ROOF FRAMING PLAN AND DETAILS
FOUNDATION PLAN, TYPICAL CROSS SECTION AND STRUCTURAL NOTES
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
UP
SAUNA
SAUNA
A1
- SCALE : 1 / 100
EXST./REMOVAL FLOOR PLAN
20,930 6,300 5,080 4,470 3,050 2,845
42,675
42,675
3,200 17,730 6,500 6,300 4,270 4,675
DRYING
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100 A-1
ARCHITECTURAL
GENERAL NOTES
BY GOVERNMENT.
INSTALLATION SHOP DRAWINGS FOR APPROVAL
4. CONTRACTOR SHALL SUBMIT MANUFACTURERS
CONSTRUCTION OR RENOVATION.
DIMENSIONS PRIOR TO COMMENCING ANY
VERIFYING ALL EXISTING CONDITION AND
1. THE CONTRACTOR SHALL BE RESPONSIBLE IN
THE CONTRACTING OFFICER.
CONDITION TO ADJACENT AREAS AS DIRECTED BY
AREAS CAUSED BY THIS PROJECT AND TO MATCH
CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO
OFFICER FOR APPROVAL.
CONDITIONS AND SUBMITTED TO THE CONTRACTING
BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD
SUCH DETAILS SHALL BE PREPARED IN THE FIELD
MAY NOT MATCH FIELD CONDITIONS EXACTLY,
3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS
BEFORE FABRICATION AND INSTALLATION.
AND DRAWING SHALL BE APPROVED BY THE C.O.R.
SHOP DRAWINGS FOR ALL DOOR AND WINDOW DETAILS
INSTRUCTIONS. THE CONTRACTOR SHALL PREPARE
I.A.W.SPECIFICATIONS AND MANUFACTURES
5. ALL DOORS AND WINDOWS SHALL BE FABRICATED
AT NO ADDITIONAL COST TO THE PROJECT CONTRACT.
ACCOMPLISH THE ARCHITECTURAL SCOPE OF WORK
(DATED 30 NOVEMBER 2015) WILL BE UTILIZED TO
THE O & MA STANDARD DETAIL DRAWINGS, 2014
6. THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN
WALL - - - - U=0.092 (R=10.86)
ROOF - - - - U=0.052 (R=19.23)
7. MAXIMUM U-FACTORS AND R-VALUE HEAT TRANSMISSION
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
GENERAL NOTES
EXISTING/REMOVAL FLOOR PLAN AND
SAUNA SAUNA
1 35
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
UP
RISER RM
SPRINKLER
CENTER
FITNESS
CENTER
FITNESS
GYMNASIUM
STORAGE
OFFICE
SUPPLY
OFFICE
ROOM
BOILER
ROOM
PUMP
AID
FIRST
CENTER
FITNESS
116A
VEST
SAUNA
VEST
CORRIDOR
SAUNA
STAIR
JAN
STOR
RM
BREAK
INSTRUCTOR
ROOM
GAS
RAMP
A1
- SCALE : 1 / 100
NEW PROPOSED FLOOR PLAN
20,930 6,300 5,080 4,470 3,050 2,845
42,675
42,675
3,200 17,730 6,500 6,300 4,270 4,675
DRYING
SHOWER
LOCKER RM
MEN'S
LATRINE(M)
ENT.HALL
TOILET
LATRINE(W)
LB LB
LK
LK
LK LK
LB
LK
LK LK
LK
LK
LB
LK
LK LK
LK
LK
JAN.
LOCKER RM
WOMEN'S
SHOWER
DRYING
LATRINE(M)
CHANGER
DIAPER
VENDING MACHINE FIT
VEST.
HALL
WATCHING AREA
2ND.FLOOR
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-2
SCOPE OF WORK
NEW PROPOSED FLOOR PLAN AND
JAN
EXTRACTOR
WATER
EXTRACTOR
WATER
W.F.
W.F.
W.F.
W.F.
A. REPAIR/ MAINTENANCE WORK
SCOPE OF WORK (BLDG.158)
INCLUDING HARDWARE AS SHOWN ON DRAWING.
5. REPLACE EXISTING DOORS AND FRAMES WITH NEW
LININGS WITH NEW AS SHOWN ON DWG.
2. REPLACE EXISTING CMU WALL AND GWB.WALL
COUNTER DOOR AS SHOWN ON DWG.
WITH NEW INCLUDING STAINLESS STEEL ROLL-UP
4. REPLACE EXISTING ISSUE COUNTER AND WINDOWS
AS SHOWN ON DWG.
FOR BUILDING TO FUNCTIONAL TRAINING ROOM
WITH NEW AT EXSITING RAQUET BALL COURT
9. REPLACE EXISTING WALL AND FLOOR SURFACES
ROOM AS SHOWN ON DWG.
13. REPLACE EXISTING SHELVES WITH NEW AT SUPPLY
GYMNASIUM ENTRANCE AS SHOWN ON DWG.
16. REPAIR BY INSTALLING METAL CANOPY FOR
AS SHOWN ON DWG.
18. REPAIR BY INSTALLING VENDING MACHINE SHED
22. PAINT ALL INTERIOR SURFACES.
SURFACES WITH NEW TILE AS SHOWN ON DWG.
24. REPLACE EXISTING INSIDE SWIMMING POOL
SWIMMING POOL ROOF.
WITH NEW BETWEEN MAIN GYMNASIUM ROOF AND
23. REPLACE EXISTING RAINGUTTERS AND DOWNSPOUTS
LK
LK
D1
D1
D4
D2
D3
D4
D3
D3 D3
D3
D4
D5
D5
D5
D6
D8
D6
D6 D6
D6
D6
D7
D7
D7
D9
D10
D5
W1
W1
W2
SYSTEM
INCL.OPERATING
WITH NEW
DIVIDER CURTAIN
REPLACE EXST.
OPERATING SYSTEM
REPLACE EXST. MAIN WINDOW
OPERATING SYSTEM
REPLACE EXST. MAIN WINDOW
TRAINING ROOM
FUNCTIONAL
S
S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
AT WATCHING AREA, 2ND.FLOOR.
WINDOW INCLUDING STAINLESS STEEL FRAMES
GUARD RAILS WITH NEW FIXED TEMPERED GLASS
20. REPLACE EXISTING CHAINLINK FENCE &
RISER ROOM CANOPY
NEW CANOPY SAME AS
SEE DETAIL
A2 A9
BB-1
AS SHOWN ON DWG.
INCLUDING CEILING SUSPENSION SYSTEM
WITH NEW GWB.CEILING AND ACST.CEILING
1. REPLACE EXISTING DETERIORATED CEILING SYSTEMS
WITH NEW AS SHOWN ON DWG.
3. REPLACE EXISTING DETERIORATED FLOOR SURFACES
WITH NEW AT LCOKER ROOM AREAS AS SHOWN ON DWG.
8. REPLACE EXISTING DETERIORATED SAUNA SYSTEMS
SLAB WITH NEW AT ROOM 114, 134 AND 135.
10. REPLACE EXISTING DETERIORATED CONCRETE FLOOR
SYSTEM WITH NEW AT ROOM 114 AND 134.
11. REPLACE EXISTING DETERIORATED KITCHENETTE
AS SHOWN ON DWG.
WITH NEW AT LOCKER ROOMS, ROOM 108 AND 135
12. REPLACE EXISTING DETERIORATED LOCKERS
WITH NEW AT GYMNASIUM AREA AS SHOWN ON DWG.
15. REPLACE EXISTING DETERIORATED DIVIDER CURTAIN
STATION WITH NEW AT WOMEN LATRINE AREA.
14. REPLACE EXISTING DETERIORATED DIAPER CHANGING
AREA AS SHOWN ON DWG.
SHADE WITH NEW ALUMINUM SHADE AT ROOF TOP
17. REPLACE EXISTING DETERIORATED WOODEN WINDOW
MAIN WINDOW OPERATING SYSTEM WITH NEW.
6. REPLACE EXISTING DETERIORATED GYMNASIUM
2 35
CABINETS WITH NEW AS SHOWN ON DWG.
21. REPLACE EXISTING FIRE EXTINGUISHERS AND
FEC
FEC
FEC
FEC
FEC
FEC
FEC
* SEE STANDARD DETAIL DWG.
AT EVERYROOM ENTRANCE AS SHOWN ON DWG.
19. REPLACE EXISTING INTERIOR SIGNAGES WITH NEW
AS SHOWN ON DWG.
AND SHOWER AREAS IN ACCORDANCE WITH NEW PLAN
7. REPAIR EXISTING DETERIORATED TOILET, LOCKER
1402670793.LN
Polygonal Line
1402670793.LN
Text Box
PHASE #1
1402670793.LN
Typewritten Text CONSTRUCTION PHASING: Facility will be occupied while work is being performed and that work will be need to be conducted in two phases. As shown on the drawing (A-2), the first phase are fitness center (Room #116, #116 A & #117), this area shall be completed within 30 days. All other area shall be completed as second phase including swimming pool area. Contractor shall submit shop drawings indicating working zones and dates for review by Government. Contractor shall not start work until phasing plan is approved.
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-3
NO.
ROOM
GYMNASIUM
JANITOR
DRYING AREA
CMU.
EXST.
CMU.
EXST.
ROOM NAME
INTERIOR FINISH SCHEDULE EXTERIOR FINISH SCHEDULE
SURFACE MATERIAL FINISH COLOR REMARKS
FLOOR BASE WAINSCOT WALL CEILING
MAT. FIN. COLOR MAT. FIN. COLOR MAT. FIN. COLOR MAT. FIN. COLOR MAT. FIN. COLOR HGT.HGT.
REMARKS
F.F. VCB F.F.
WINDOW
STEEL PAINT
ACST.: 15mm x600x600
CMT GCWT
GCWT F.F.
PAINT
CORRIDOR
OFFICE
VCB
VESTIBULE
VESTIBULE
VESTIBULE
SUPPLY OFFICE
STORAGE
RAMP
BREAK ROOM
RISER ROOM
BOILER ROOM
F.F.
F.F.
VCB F.F.
F.F.
PAINT
ACST. F.F.
ACST. F.F.
PAINT**GWB.
EXST.
ACST. F.F.
VARIOUS
F.F.
DOOR
2,400
3,000
2,400
2,400
2,400
2,700
2,700
VARIOUS
2,700
2,700
3,000
3,000
2,700
2,700
2,700
2,700
2,700
2,700
2,700
2,700
2,700
2,700
PAINT 6,000
ALUMINUM
HALL
STAIR
MALE LATRINE
F.TRAINING ROOM
FITNESS CENTER
FITNESS CENTER
TOILET ENT.HALL
MALE LATRINE
MEN'S LOCKER RM.
MEN'S SHOWER
JANITOR ROOM
FEMALE LATRINE
WOMEN'S LOCKER RM.
DRYING AREA
WOMEN'S SHOWER
JANITOR ROOM
STORAGE
PUMP ROOM
GAS ROOM
FIRST AID
INSTRUCTOR ROOM
WATCHING ROOM
PVCT.
PVCT.
RT-1
RF-1
CMT
PVCT.
HDR-1
PVCT.
HDR-1PAINT PAINT
F.F.
F.F.
F.F. F.F.
GTB-1
VCB
VCB
F.F.
F.F.
RFB-1 F.F.
GCWT F.F.
CRWC F.F. 2,400
*GWB.
GYPSUM WALL BOARD : THK.12.5mm
*GWB.:12.5mmTHK.WATERPROOF TYPE GWB.PAINT
EXST.
GCWT F.F.
EXST.
PAINT
PAINT
ACST.: 15mm x600x600
*GWB.
*GWB.:12.5mmTHK.WATERPROOF TYPE GWB.
*GWB.:12.5mmTHK.WATERPROOF TYPE GWB.
**GWB:12.5mmTHK.X-TYPE GWB.
ACST.
*GWB.
F.F.
PAINT
ACST.: 15mm x600x600
2,700
2,700
VARIOUSVARIOUSVARIOUS
VARIOUS
2,400
2,7002,700
2,700
MATERIAL & COLOR SCHEDULE
INTERIOR & EXTERIOR FINISH SCHEDULE,
CANOPY PAINTMETAL
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
BY USER
DETERMINED
PVCT.
RT-1
*GWB.:12.5mmTHK.WATERPROOF TYPE GWB.
GWB.
GCWT/
PAINT
F.F./
ACST.: 15mm x600x600
3 35
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-4
MATERIAL AND COLOR SCHEDULE GENERAL NOTE
FLOOR MATERIAL/COLOR BASE MATERIAL/COLOR
BB-1 BULLETIN BOARD
MISC MATERIAL/COLOR
P-1 PAINT, LATEX / SEMIGLOSS:
OR APPROVED EQUAL
SIZE - 2000(W) x 1000(H)
MEDIUM GREY
POSTER PANEL - FABRICORK
FRAME - 50THK SST, SATIN FINISH
THE MOON CO.LTD
SSM-1 SOLID SURFACE MATERIAL :
CORIAN, WALL
AZTEC GOLD
OR APPROVED EQUAL
SSM-2 SOLID SURFACE MATERIAL :
CORIAN, WALL RAIL & COUNTER TOP
BLACK QUARTS
OR APPROVED EQUAL
SSM-3 SOLID SURFACE MATERIAL :
CORIAN, LIGHTING POCKET
LIME ICE
OR APPROVED EQUAL
NR7001
NOROO
OR APPROVED EQUAL
P-2 :
NR7001
P-3
NOROO
OR APPROVED EQUAL
PAINT, ALKYD/ SEMIGLOSS:
NR9105
P-4
NOROO
OR APPROVED EQUAL
PAINT, LATEX / SEMIGLOSS:
NR3138 FOR DOOR, NR3140 FOR FRAME
P-5
NOROO
OR APPROVED EQUAL
PAINT, ALKYD / SEMIGLOSS:
FOR METAL DOOR & METAL FRAME
SSM-4 SOLID SURFACE MATERIAL :
CORIAN
ECRU,
OR APPROVED EQUAL
TOILET PARTITION, SHOWER PARTITION
WD-1 WOOD TRIM:
OAK, NATURAL, VARNISH
PVCT-1 :
OR APPROVED EQUAL
KCC EXCELLENT (NON-ACM)
* GROUT COLOR FOR FCT
OR APPROVED EQUAL
MOLD & MILDEW RESISTANT, STAIN PROOF
BROWN GREY
HDR-1 :HARDENER
NOROO, DENSIL
CDA-300, CLEAR COATING
RF-1 :RUBBER FLOORING
GOPHERSPORT.COM
OR APPROVED EQUAL
1219x1829x19THK
RUBBER MAT
GRAY W/ BLACK CHIPS
OR APPROVED EQUAL
FG 7 L67-1, MARON
SLM-1 :
SIKA KOREA,
SIKA FLOOR-LEVEL 25,
CEMENTITIOUS SELF SMOOTHING
INDUSTRIAL SUB-FLOOR SCREED
OR APPROVED EQUAL
RFB-1 RUBBER FLOORING BASE:
GOPHER.COM, 19THK, RUBBER
BLACK W/ GRAY BLUE COLOR
FLECKS
OR APPROVED EQUAL
VCB-1 VINYL COVE BASE:
OR APPROVED EQUAL
WALL MATERIAL/COLOR
* GROUT COLOR FOR GCWT
OR APPROVED EQUAL
MOLD & MILDEW RESISTANT, STAIN PROOF
WHITE
CEILING MATERIAL/COLOR
ACST-1 :ACOUSTICAL CEILING TILE
W/23 TEE GRID
OR APPROVED EQUAL
NR7001
NOROO
OR APPROVED EQUAL
PAINT, EPOXY / GLOSS
CRWC-1 CORRUGATED RUBBER WALL COVERING:
DAESANSPORTECH, DOUBLE IMPACT
ABSORPTION SAFETY RIB,
30THK, TRECTANGULAR TYPE
LIGHT GRAY
OR APPROVED EQUAL
SWK-1 :SAUNA WOOD KIT,
AMEREC (WWW.DLHOMES.CO.KR)
RED CEDAR FINISH
WOOD FLOOR, WALL, CEILING
& BENCHES
HEATER(VERIFY PER ROOM SIZE),
DELUXE FULL GLAZED WOOD DOOR,
LIGHT DIGITAL CONTROLER,
OR APPROVED EQUAL
DC-1 :DIVIDER CURTAIN
PORTER,
SLOPED-FOLD GYMNASIUM,
DIVIDER CURTAIN-90665000,
VINYL FABRIC-BLACK #12,
& ACCESSORIES
MESH-WHITE W/ ELECTRIC OPERATOR,
OR APPROVED EQUAL
LK-1 :LOCKER
IDES I & F INC. www.ides.co.kr
MODEL B-2 DOUBLE TIER LOCKER
400W x 500D x 1800H x 100H base, HARDWARE / 1-COAT ROD, 2-COAT HOOK
LOCKER DOORS; 18THK ANSI 208.2 GRADE
MDF CORE WITH BLACK GLOSSY
PLASTIC LAMINATE FINISH,
LOCKER BOX ; 18THK ANSI 208.1 GRADE
OR APPROVED EQUAL
LB-1 :LOCKER BENCH
WWW.IDES.CO.KR
OR APPROVED EQUAL
BLACK STAINED OAK W/ IV COAT
610W x 1800L x 450H
OR APPROVED EQUAL
& URINAL SCREEN
:GLAZED CERAMIC WALL TILE
OR APPROVED EQUAL
HD-1 :HAND DRYER
CHEONHO TONGSANG/ SK
OR APPROVED EQUAL
SMART AIR, SHD-100U
254x163x214(H)
P-6 :PAINT, LATEX / SEMIGLOSS
NR3188
NOROO
OR APPROVED EQUAL
MB-1 :MINI BLIND @ INTERIOR WINDOW (TYP)
HANDKOOK BLIND
25W, AL,
MATCH TO WALL COLOR
OR APPROVED EQUAL
& DIGITAL KEYPAD LOCK W/ RECESS HANDLE
PARTICLEBOARD CORE WITH BLACK
MELAMINE FINISH W/ MIRROR END PANEL
MELATONE #4011 HG (OR DT0029 TX),
INDICATED AND CONFORMS TO ALL REQUIREMENTS.
COLORS AND PATTERNS CLOSELY APPROXIMATE THOSE
PRODUCTS OF OTHER MANUFACTURERS ARE ACCEPTABLE IF
CONFORM TO ALL SPECIFIED REQUIREMENTS.
ONLY AND ACCEPTALBE FOR USE IN THIS PROJECT ONLY IF THEY
DESIGNATIONS ARE FOR THE PURPOSE OF COLOR DESIGNATION
1. MATERIAL INDICATED WITH MANUFACTURER'S NAME AND COLOR
2. ALL EXTERIOR COLOR SHALL BE APPROVED BY DPW.
- POC : MR. ERIC U. YIM
BY USING AGENCY.
3. ALL INTERIOR COLOR & FINISH MATERIAL SHALL BE APPROVED
(ROOM NO. 108, 134 & 135)
SELF LEVEL MORTAR
603MM x 603MM x 15MM THK.
"KCC MITONE"
MC 3102
WHITE
LG HAUSYS
DARK BROWN, 100 HGT. 3 THK.
CMT NON-SLIP CERAMIC FLOOR TILE
DONGSEO, INUS
NON-SLIP, 300 x 300 x 8THK.
P. VINYL COMPOSITION TILE
450 x 450 x 3 THK.
GCWT
DONGSEO, INUS
LQR 1N92-1, GLOSS
300 x 600 x 10THK.
CONCRETE SLAB FOR FLAT SURFACE.
TO FINISH FLOOR AT ALL EXISTING AND NEW
* SELF LEVELING UNDERLAY SHALL BE APPLIED
RT-1 :
OR APPROVED EQUAL
RUBBER TILE
I-BADAK FLOORING SYSTEM
CMR42, 3THK. FOR FLOOR,
SOCR42, 3THK. FOR TREAD/RISER
RMCMU, 2THK. FOR STRINGER AND BASE
GENERAL NOTE
MATERIAL & COLOR SCHEDULE AND
BY FORMICA OR APPROVED EQUAL.
7737-58, NATURAL CHERRY, MATTE
PLASTIC LAMINATE, COLOR:
BY FORMICA OR APPROVED EQUAL.
756-58, NATURAL MAPLE, MATTE
PLASTIC LAMINATE, COLOR:
PL-1
PL-2
4 35
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-5
RM
BREAK
LATRINE(M)
SAUNA
DRYING
SHOWER
LOCKER RM
MEN'S
LATRINE(M)
ENT.HALL
TOILET
LK
LK
LK LK
LK LK
LK
LK
JAN
EXTRACTOR
WATER
D6 D6 D7
WATER
FOUNTAIN
WATER
FOUNTAIN
HD-1
US
US
US
TTD
TTD
TTD
TTD
TTD
MR
GB
GB
GB
SD
SD
SD
SD
SMLD
SMLD
SMLD
SMLD
MG
MG
MG
MG
LB-1 LB-1
SWK-1
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SMLD
SMLD
SMLD
SMLD
SMLD
SMLD
SMLD
SMLD
SMLD
SMLD
SP
SP
SP
SP SP
SP
SP
SP
SCR
SCR
SB
SB
SB
RH
RH
RH
RH
RH-P
RH-P
RH-P
W/R
PTD
3,650 250 7,150 400 3,300 250
15,000
3,908 2,388 1,000 1,0001,626 3,328 1,500 250
15,000
,7
,3
,2
,0
,0
,0
,0
,2
,7
,6
,8
,8
US
TTD
RH
TTD
RH
W/R
PTD
SD
SD
SMLD
SMLD
4,650
2004,450
,8
,6
,6
ENLARGED PARTIAL PLAN
SCALE : 1 / 50
TOILET ACCESSORIES SCHEDULE
ENLAGED PARTIAL PLANS AND
A5A2
1 ENLARGED PARTIAL PLAN
SCALE : 1 / 50A5A2
5.
6.
7.
1.
2.
3.
4.
8.
KITCHENETTE NOTE
AND TO BE INSTALLED BY OTHER.
GOVERNMENT FURNISHED MATERIALS
MICROWAVE,RANGE AND REFRIGERATOR WILL BE
TWO (2) INCHES ACTURAL SIZE OF THE REF.)
JOB SITE, (REFRIGERATOR SPACE SHALL BE
AND CABINET SIZE WILL BE ADJUSTED ON THE
REFRIGERATOR DIMENSION IS APPROXIMATE
SELECTED BY USING AGENCY.
PLASTIC LAMINATED COLOR TO BE
(PL-1).
PLYWD PANEL W/ PLASTIC LAMINATE
CONSTRUCTED OF SOLID WD TRIMS &
END PANEL AND ETC. SHALL BE
INCLUDING DOOR, DRAWER FRONTS, SIDE
ALL EXPOSED COUNTER CABINET FACES
(PL-2).
FINISHED W/ PLASTIC LAMINATE
ALL CABINET INSIDE SURFACE SHALL BE
FINISHED W/ SOLID SURFACE MATERIAL (SSM-1).
ALL CABINET COUNTERTOP SHALL BE
FOR THE SOUND SILENCE.
EQUIPPED WITH RUBBER BUMPER
ALL CABINET DOORS SHALL BE
SOLID SURFACE MATERIALS FOR APPROVAL.
OF HARDWARE, PLYWOOD, PLASTIC LAMINATE &
AND TEST REPORTS, CERTIFICATIONS
OF KITCHEN CABINETS WITH HARDWARE,
CONTRACTOR SHOULD SUBMIT SHOP DRAWING
TOILET ACCESSORIES SCHEDULE
ITEM REMARK
SMLD
TTD
SD SOAP DISH
SHELF METAL LIGHT DUTY
TOILET TISSUE DISPENSER * 2-ROLLTYPE
PTD PAPER TOWEL DISPENSER
TOILET PARTITION
ROBE HOOK
Q'TY
MOP RACK
MIRROR GLASSMG
RH
MR
* FIT TO WALL WIDTH
US
LAVATORY COUNTER
* W/RECEPTACLE TYPE
2GB GRAB BAR
* SSM-2 (CORIAN, SEE AE103)
RM#113 RM#119 RM#120 RM#121/122
MG MIRROR GLASS
SP
SB
SCR
LB
LK
SHOWER CURTAIN & ROD
URINAL SCREEN
SHOWER PARTITION
SHOWER BENCH
LOCKER BENCH
LOCKER
* SEE STD.DETAIL DWG.
* SSM-4
* SSM-4
35 x 2 = 70
3 * FIT TO WALL WIDTH
THK.8mm TEMPERED ETCHING GLASS
* SEE MATERIAL SCHEDULE (A-4)
* SEE MATERIAL SCHEDULE (A-4)
ON EXST.CMU.
ON W.P.MEMBRANE
ON METAL LATH
GCWT.ON CEMENT MORTAR
@300 O.C.
ON 90mmTHK.METAL STUD
ON 12mmTHK.CEMENT BD.
ON W.P.MEMBRANE
ON METAL LATH
GCWT.ON CEMENT MORTAR
CMT
PVCT
WALL
GWB.
GCWT.
* GCWT. ON
PIPECHASE WALL
W/METAL STUDS
* GCWT. ON
EXST./EXTENDED
CMU WALL
5 35
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-6
SAUNA
LATRINE(W)
LK
LK
LK LK
LK
LK
JAN.
LOCKER RM
WOMEN'S
SHOWER
DRYING
EXTRACTOR
WATER
D6
D6
D7
CHANGING STATION
DIAPER
TOILET ACCESSORIES SCHEDULE
ENLAGED PARTIAL PLANS AND
ENLARGED PARTIAL PLAN
SCALE : 1 / 50A6A2
TOILET ACCESSORIES SCHEDULE
ITEM REMARK
SMLD
TTD
SD SOAP DISH
SHELF METAL LIGHT DUTY
TOILET TISSUE DISPENSER * 2-ROLLTYPE
PTD PAPER TOWEL DISPENSER
TOILET PARTITION
ROBE HOOK
Q'TY
MOP RACK
MIRROR GLASSMG
RH
MR
* FIT TO WALL WIDTH
US
LAVATORY COUNTER
* W/RECEPTACLE TYPE
GB GRAB BAR
* SSM-2 (CORIAN, SEE AE103)
RM#125 RM#126/127
MG MIRROR GLASS
SP
SB
SCR
LB
LK
SHOWER CURTAIN & ROD
URINAL SCREEN
SHOWER PARTITION
SHOWER BENCH
LOCKER BENCH
LOCKER
* SSM-4
* SSM-4
FOUNTAIN
WATER
1,900 1,000 400
3,300 3,350 250
6,900
6,900
1,0001,0001,0001,200200 1002,400
,7
,5
,5
,0
,0
,0
,0
,0
,6
,6
,6
1,050
20 750 280
HOLDER
STAINLESS STEEL
HOLDER
STAINLESS STEEL
HOLDER
STAINLESS STEEL
HOLDER
STAINLESS STEEL
CLAMP
STAINLESS STEEL
CURTAIN
SHOWER
STAINLESS STEEL PIPE
30mm DIA.
SHOWER CURTAIN ROD
STAINLESS STEEL
30mm DIA.
SCALE : 1 / 20A6A2
2 SHOWER PARTITION DETAIL
FOR APPROVAL BY GOVERNMENT.
AND CURTAIN RODS INSTALLATION SHOP DRAWINGS
* CONTRACTOR SHALL SUBMIT GLASS PARTITIONS
* SEE STD.DETAIL DWG.
* FIT TO WALL WIDTH
THK.8mm TEMPERED ETCHING GLASS
* SEE MATERIAL SCHEDULE (A-4)
* SEE MATERIAL SCHEDULE (A-4)
THK.8mm TEMPERED
ETCHING GLASS
RH
RH
RH
RH
TTD
TTD
TTD
TTD
GB
GB
MR
HD-1W/R
PTD
FOUNTAIN
WATER
LB-1
LB-1
SD SD SD SD
SDSDSDSD
SMLD SMLD SMLD SMLD
SMLDSMLDSMLDSMLD
GB
SB
SB
SB
SCR
SCR SCR SCR
SCRSCRSCRSCR
SP SP SP
SPSPSP
SCR
SCR
RH-P
RH-P
RH-P
25 x 2 = 50
RM#124/129
MGSD SD SD SD
SMLD
SMLD
SMLD SMLD
MG
MG MG MG
6 35
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-7
INSULATING GLASS UNIT
* 18mmTHK. (6+6+6)
D1
* 2EA-450x800x6mm WIRED OPAQUE GLASS
WITH STEEL DOOR FRAME
* WOOD FLUSH, SOLID CORE, SINGLE DOOR
WOODEN LOUVER
300 x 250
* 300 x 250 WOODEN LOUVER
JANITOR ROOMD7
W1
TRIM
OAK WOOD
STOOL
OAK WOOD
INSECT SCREEN
WEATHERSTRIPPING AND WINDOW FASTENER
THERMAL BREAK TYPE INCLUDING INSECT SCREEN,
WITH ALUM. FRAME, ANODIZED DARK BRONZE,
* ALUMINUM SASH SLIDING BLAST WINDOW
+ THK.6mm TINTED LOW-E TEMPERED GLASS
+ THK.12mm AIR SPACE
THK.8.75mm LAMINATED GLASS
(THK.25mm)
* REPLACE WINDOW BLINDS WITH NEW AT ALL NEW WINDOWS.
- INSULATING CLEAR GLASS UNIT (8.75+12+6)
* W1 - SIZE : 1200 x 1000 x THK.130mm
NOTES
AND INSTALLATION
BY THE CONTRACTING OFFICER BEFORE FABRICATION
ALL DOORS AND WINDOWS. THESE SHALL BE APPROVED
2. THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR
"BEST-LOCK" OR APPROVED EQUAL.
4. ALL LOCKS SHALL UTILIZED INTERCHANGEABLE CORE
FRAME DESIGNED IN ACCORDANCE WITH ASTM F2248.
PROVIDE WINDOW PRODUCT INCLUDING GLAZING AND
5. SPECIAL NOTE FOR WINDOW GLAZING AND FRAMES :
TO EXISTING.
* CODDIDOR SIDE WOOD FLUSH DOOR COLOR MATCH
COATED NATURAL COLOR FINISH.
3. WOOD FLUSH DOORS SHALL BE FINISHED FACTORY
PRIOR TO COMMENCING WORK.
REQUIRE APPROVAL BY THE CONTRACTING OFFICER
SCHEDULE AND MANUFACTURES' INSTRUCTIONS
IN ACCORDANCE WITH SPECIFICATIONS, HARDWARE
1. ALL DOORS AND WINDOWS SHALL BE FABRICATED
ANTITERRORISM STANDARDS FOR BUILDING.
ACCORDANCE WITH UFC 4-010-01, DoD MINIMUM
6. WINDOW PRODUCT INSTALLATION SHALL BE IN
TRIM
OAK WOOD
STOOL
OAK WOOD
W2
WITH ASTRAGAL TYPE#21
1 - DOOR COORDINATOR
1 - WEATHER STRIPPING
2 - KICK PLATE, J102
2 - DOOR STOP & HOLDER, L01371
1 - THRESHOLD, J32190
2 - DOOR CLOSER, C02021
(TYPE"2" AND FUNCTION "01")
1 - EXIT DEVICE (PUSH PAD TYPE)
(TYPE"3" AND FUNCTION "05")
1 - EXIT DEVICE (PUSH PAD TYPE)
6 - BUTT, HINGES TYPE A5112 (NRP)
HDW - MAIN ENT.
AND WEATHERSTRIPPING
BLAST DOOR WITH STEEL DOOR FRAME
* STEEL FLUSH, INSULATED DOUBLE
MAIN ENT. D3 PASSAGE DOOR
1 - THRESHOLD, J32100
2 - DOOR STOPS, L02161
2 - PUSH AND PULL BAR
W/PIVOT CO7121
2 - FLOOR CLOSER, CO6041
HDW - PASSAGE
D4
DOOR WITH STEEL DOOR FRAME
* STEEL FLUSH, HOLLOW CORE DOUBLE
FITNESS GYM.ENTRANCE
2 - KICK PLATE, J102
2 - DOOR HOLDER, L01381
2 - DOOR STOP , L02161
1 - THRESHOLD, J38130
2 - DOOR CLOSER, C02021
(TYPE"2" AND FUNCTION "01")
1 - EXIT DEVICE (PUSH PAD TYPE)
(TYPE"2" AND FUNCTION "08")
1 - EXIT DEVICE (LEVER TYPE HANDLE)
6 - BUTT, HINGES TYPE A5112 (NRP)
HDW - FITNESS GYM.ENTRANCE
D2
WITH ASTRAGAL TYPE#21
1 - DOOR COORDINATOR
1 - WEATHER STRIPPING
2 - KICK PLATE, J102
2 - DOOR STOP & HOLDER, L01371
1 - THRESHOLD, J32190
2 - DOOR CLOSER, C02021
(TYPE"2" AND FUNCTION "01")
1 - EXIT DEVICE (PUSH PAD TYPE)
(TYPE"3" AND FUNCTION "05")
1 - EXIT DEVICE (PUSH PAD TYPE)
6 - BUTT, HINGES TYPE A5112 (NRP)
HDW - MAIN ENT.
AND WEATHERSTRIPPING
BLAST DOOR WITH STEEL DOOR FRAME
* STEEL FLUSH, INSULATED DOUBLE
MAIN ENT.
AL.FRAME (DARK BRONZE)
LAMINATED GLASS W/ANNODIZED
* AL.DOOR W/CLEAR THK.6.75mm
* 1• HOUR FIRE RATED DOOR
LAMINATED CLEAR GLASS
2EA.-450x800x6.75mm
* FIRE RATED GLASS DOOR
WITH STEEL DOOR FRAME
* WOOD FLUSH, SOLID CORE, SINGLE DOOR
1 - THRESHOLD, J32140
1 - DOOR HOLDER, L01381
1 - DOOR STOP, L02161
1 - KICK PLATE J102
1 - DOOR CLOSER CO2021
1 - LOCKSET, F82
3 - BUTT, HINGES TYPE A5112
HDW - OFFICE
D5 OFFICE
* 150x750x6.75mm LAMINATED OPAQUE GLASS
WITH STEEL DOOR FRAME
* WOOD FLUSH, SOLID CORE, SINGLE DOOR
* 20mm UNDER CUT
D6
* 400 x 300 WOODEN LOUVER
TOILET/BREAK ROOM
WOODEN LOUVER
400 x 300
(RM.NO.113 & 114)
WOODEN LOUVER
* 250 x 200
(RM.NO.113 & 114)
* 250 x 200 WOODEN LOUVER
1 - ALUMINUM THRESHOLD J32180
1 - DOOR STOP, L02161
1 - KICK PLATE, J102
1 - DOOR CLOSER CO2021
1 - PULL PLATE, J401
1 - PUSH PLATE, J301
HDW - LATRINE
1 - ALUMINUM THRESHOLD J32180
1 - DOOR STOP, L02161
1 - KICK PLATE J102
1 - DOOR CLOSER CO2011
1 - LOCKSET, F86
HDW - STORAGE/ JANITOR
D8 TRAINING ROOM
1 - SAFETY RUBBER STRIPPING FOR GLASS DOOR
2 - DOOR HANDLE
1 - DOOR STOP, L02161
1 - DEAD LOCK (TOP & BOTTOM)
1 - FLUSH BOLT (TOP & BOTTOM)
1 - THRESHOLD, J32180
1 - THRESHOLD FOR FLOOR CLOSER, C08011
1 - TOP PIVOT HINGE, C07021
1 - FLOOR CONECEALED CLOSER, C06012
HDW - TEMPERED GLASS DOOR
WITH STAINLESS STEEL DOOR FRAME
* TEMPERED GLASS SINGLE DOOR (THK.12mm)
D9 EXIT DOOR
* 1• HOUR FIRE RATED DOOR
LAMINATED CLEAR GLASS
450x800xTHK.6.75mm
* FIRE RATED GLASS DOOR
SINGLE DOOR WITH STEEL DOOR FRAME
* STEEL FLUSH, HOLLOW CORE HALF GLASS
AL.FRAME (DARK BRONZE)
LAMINATED GLASS W/ANNODIZED
* AL.DOOR W/CLEAR THK.6.75mm
D10 FIRST AID
1 - THRESHOLD, J32180
1 - DOOR STOP, L01371
1 - PUSH AND PULL BAR
W/PIVOT CO7121
1 - FLOOR CLOSER, CO6041
HDW - FIRST AID
THK.6.75mm LAMINATED GLASS
AND WINDOW FASTENER
ALUM. FRAME, ANODIZED DARK BRONZE,
* ALUMINUM SASH SLIDING WINDOW WITH
- THK.6.75mm LAMINATED CLEAR GLASS
* W2 - SIZE : 1000 x 800 x THK.130mm
A7
A2 NOT TO SCALE
DOOR & WINDOW DESCRIPTIONS AND NOTES
DOOR & WINDOW DESCRIPTIONS
1 - THRESH HOLD, J38130
1 - DOOR HOLDER, L01381
1 - DOOR STOP, L02161
1 - KICK PLATE, J102
1 - DOOR CLOSER, C02021
1 - LOCKSET, F08 (LEVER HANDLE TYPE)
3 - BUTT, HINGES TYPE A5112 (NRP)
HDW - EXIT DOOR
7 35
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-8
WATCHING AREA
2ND.FLOOR
B
A B
(3-PER SIDE)
MET.SCREW
6DIA.
ELEVATION SECTION
PAPER TOWEL DISPENSER W/RECEPTACLE
NOT TO SCALE
OVERALL SIZE
WALL
GCWT.
(ALL AROUND)
WOOD SHIM
25THK.WOOD
TUBE FRAME(TYP.)
-50x50x6 ST'L
GALV.
200 275 150
@600 O.C.
TOGGLE BOLT
3EA.-18DIA.
(SEE MECH.DWG.)
LAVATORY
TYP.LAVATORY COUNTER DETAIL
NOT TO SCALE
MIRROR
* NOTE : VERIFY DIMENSION W/MFR.PER SPEC.
MET.STUD
ANCHOR TO
ST'L PLATE
400x2,400x4THK.
OVER 18THK.PLYWOOD
COUNTER TOP & SPLASH BACK
(SSM-1)
SOLID SURFACING MATERIAL
POST-FORMED 13THK
ON12THK.PLY WD.
SSM-2(6THK.)
REMOVABLE PANEL
INSULATION
INCL.SOUND PROOF
@300 O.C.
ON 90/150mmTHK.METAL STUD
ON 12mmTHK.CEMENT BOARD
ON W.P.MEMBRANE
ON METAL LATH
GCWT.ON CEMENT MORTAR
D9
FLOORING
RUBBER TILE
VENT.LOUVER OPENING
BLOCK-UP AND PATCH EXST.
FLOORING
RUBBER TILE
STAINLESS ST'L FRAMES
W/100x50xTHK.1.2mm
FIXED WINDOW
THK.10mm TEMPERED GLASS
6,300 2,235
SECOND FLOOR ENLARGED PLAN
A8 SCALE : 1 / 50
LADDER WITH NEW
INCLUDING STEEL
DOOR/FRAME
REPLACE EXST.STEEL
& GUARD RAILS
PAINT EXST.WALL
CMT W/MORTAR BED
2-PLY,30# ASPHALT FELT
25x38 WOOD NAILER
FRONT STRIP
38x50 HARD WOOD
OFFICE
VCB
C L
G
H
T
PL-1 ON 19T PLYWOOD
,7
A8 SCALE : 1 / 20
2 SUPPLY OFFICE SHELVES
PVCT.
12.5 THK GWB
PAINT ON
A8A8
AND DETAILS
SECON FLOOR ENLARGED PLAN
A2 A2
A2 A2
A
AT ROOF TOP AREA(OUTSIDE OF DOOR"A").
WINDOW SHADE WITH NEW ALUMINUM SHADE
* REPLACE EXISTING DETERIORATED WOODEN
AND BLADES (DARK BROWN)
- ANNODIZED ALUMINUM FRAMES
- SIZE: 2EA.x5,000x1,100
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
1:100
ARCHITECTURAL
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
188985
A-9
* SEE NOTE
ROLL-UP DOOR
STAINLESS STEEL
A9
A2 SCALE : 1 / 20
SUPPLY OFFICE
FRONT VIEW SECTION
* NOTE : STAINLESS STEEL ROLL-UP DOOR
ISSUE COUNTER DETAIL
2,000100 100
,1
,1
,2
PVCT.
(SSM-2)
COUNTER TOP
(SSM-2)
FRAME
HALL
(SSM-2)
FRAME
(SSM-2)
COUNTER TOP
(SSM-1)
PANEL
KICK PLATE
GWB.WALL
THK.12.5mm
PAINT ON NEW
@300 O.C.
METAL STUD
W/THK.150mm
THK.12.5mm GWB.
PAINT ON
* OR APPROVED EUAL.
FINISH STAINLESS STEEL SHAPE CURTAIN.
FORMED OF 16 GUAGE 300 SERIES #4
INTEGRAL WELDED HEAD AND JAMBS ARE
- MATERIALS AND FINISHES :
- OPERATION : PUSH-UP OR HAND CRANK
INTEGRAL FRAME)
(ROLLING COUNTER DOORS WITH
- MODEL : MODEL ESC 20
(www.danieloverheaddoor.com)
& FIREPLACE
- MANUFACTURER : DANIEL OVERHEAD DOOR
A9
A2 SCALE : 1 / 50
VENDING MACHINE FIT PLAN
A9
A2 SCALE : 1 / 50
FUNCTIONAL TRAINING ROOM DETAIL
(SSM-1)
BASE
PANEL &
KICK PLATE
VENDING MACHINE FIT
EXST.SIDE WALK
5,000
NEW CONC.PAD
MISC. DETAILS
CONC.SPLASH BLOCK
PLAN
SIDE VIEW
2,000
DOWNSPOUTS
RAINGUTTER &
W/METAL ROOF,
CMU.WALL
THK.200mm
PAINT ON
EXST.SIDEWALK
NEW CON.PAD
CMU WALL
THK.200mm
PAINT ON
METAL ROOF
PAINT ON
& DOWNSPOUTS
METAL RAIN GUTTER
PAINT ON
PAINT ON EXST.WALL
,4
RFB
MORTAR(TYP.)
W/SELF LEVELING
THK.20mm RF.
ON EXST.WALL
@400 O.C.
FURRING CHANNEL
ON THK.38mm ON THK.12mm PLYWOOD
WALL COVERING
CORRUGATED RUBBER
20THK.RFB.
20THK.RF.WOOD
38x100
RFB BASE DETAIL
ON EXST.WALL
@400 O.C.
FURRING CHANNEL
ON THK.38mm ON THK.12mm PLYWOOD
WALL COVERING
CORRUGATED RUBBER
FLOOR LEVEL
EXST.WOODEN
SEE RFB BASE DETAIL
FOR MATCHING TO PREVIOUS LEVEL
W/150x150x2.1x2.1 W.W.F.
APPLY CONCRETE TOPPING
* REMOVE EXST.WOODEN FLOOR AND
9 35
SPECIFICATION.
FIRE EXTINGUISHER CABINET.
SEMI-RECESSED STYLE,
MATERIAL (CODE) --- STAINLESS STEEL (304) TRIM & DOOR
GLASS ------------- ‚" THK. FLEXIGLASS, CLEAR
TANK--------------- #20 GA. CHROM STEEL
TRIM & DOOR ----- #20 GA. STAINLESS STEEL
NOTE
- MANUFACTURER : BADGER or AMOREX (or APPROVED EQUAL.)
- CAPACITY : 10 pound
- TYPE : ABC
2. FIRE EXTINGUISHER FURNISHED BY CONTRACTOR
750 TO FLOOR
FIRE EXTINGUISHER CABINET DETAIL
1. ALL STEEL CABINETS SHALL HAVE SQUARE EDGE ON TRIM.
NOT TO SCALEA9
A2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
KIM, YK
10 35 A-10
ARCHITECTURAL
ROOM
INDOOR SWIMMING POOL
ROOM
EQUIP.
25,000
,6
,6
3.5F 4 4.5 5 6 7 8 9
,7
,0
,6
SCALE : 1 / 100
SCALE : 1 / 100
2 SWIMMING POOL SIDE ELEVATION
188985
AS SHOWN
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
SWIMMING POOL FLOOR PLAN
AND ELEVATION
SWIMMING POOL FLOOR PLAN
NOTE
STAINLESS ST'L LADDER
* REPLACE ALL EXST.LADDER W/NEW
W/NEW STAINLESS ST'L COVER
* REPLACE ALL EXST.GRATING COVER
EXST.FLOOR
POOL TILES
REPAIR BY INSTALLING
A10
A10
FOR GOVERNMENT APPROVAL BEFORE INSTALLATION.
9. TILE AND MATERIAL SAMPLES SHALL BE SUBMITTED
INSTALLED WITH A WATERPROOF SEAL.
SUCH AS FITTINGS AND WALL ANCHORS SHALL BE
8. ALL PENETRATIONS INTO THE POOL WALLS OR BOTTOM
DEWATERING, AS NECESSARY.
DURING CONSTRUCTION, INCLUDING PUMPING AND
THE CONTRACTOR IS REQUIRED TO MAINTAIN DRAINAGE
AND FREE FLOWING.
THE GRADING LIMITS SHOWN SHALL BE KEPT CLEANED
7. ALL EXISTING INLETS, DRAINS AND PIPES WITHIN
TILE INSTALLATION.
6. REPAIR CRACKS IN FLOOR & WALL SURFACES BEFORE
STEEL PRODUCTS AS SHOWN ON DRAWING.
5. REPLACE METAL ACCESSORIES WITH NEW STAINLESS
PIPE HOLES TO NEW TILE SURFACE.
4. RAISE UP HAND HOLES, DRAINAGE INLETS AND
BEFORE PURCHASING.
INLET, AND OTHER MARKS FOR GOVERNMENT APPROVAL
SIGNAGE, RED CIRCLE AROUND BOTTOM DRAINAGE
SUBMIT SHOP DRAWING SHOWING TILE PATTERNS,
3. INSTALL SIGNAGE AS PER EXISTING LOCATION.
JOINT.
TO BE LOCATED WITH THE EXISTING EXPANSION
2. INSTALL SWIMMING POOL TILE EXPANSION JOINT
OTHER APPROVED METHOD.
PAINTS COMPLETELY, USING SAND BLAST OR
1. REMOVE ALL EXISTING DETERIORATED/PEAR-OFF
KIM, SM
MECHANICAL
1 18 M-1
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SCOPE OF WORK (MECHANICAL)
NOTE :
A. REPAIR/MAINTENANCE (K-WORK)
GENERAL NOTES
ABBREVIATIONS AND LEGEND
REGISTER, CEILING
EXHAUST AIR GRILLE OR
REGISTER, CEILING
SUPPLY AIR GRILLE OR
REGISTER, CEILING
RETURN AIR GRILLE OR
VOLUME DAMPER
kW KILOWATT
LITERS PER SECONDLPS
HORSEPOWERHP
VOLTV
TYPICALTYP
AMP AMPERE (AMP, AMPS)
Hz HERTZ
Ph PHASE (ELECTRIC)
Pa PASCAL
VD VOLUME DAMPER
MD MOTORIZED DAMPER
RR
RG
SR
SG
ER
EG
10. SALVAGEABLE MATERIALS SHALL BE RETURNED TO DPW.
AND THE LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE U.S. GOVERNMENT.
9. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, WALLS, CEILING, ROOF, PIPE, DUCT, EQUIPMENT AND ELECTRICAL ITEMS.
NO ADDITIONAL COST TO THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED TO ITEMS SUCH AS
NECESSARY TO ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS
SPECIFICATIONS FOR MISCELLANEOUS PROJECTS, KOREA.
ACCORDANCE WITH APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL
7. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT
TO THE U.S. GOVERNMENT.
THE DETAILS WILL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK AT NO ADDITIONAL COST
6. FOR O&MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT.
5. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.
AS REQUIRED BY THE CONTRACT SPECIFICATIONS.
SYSTEM WHICH MAY DEVIATE FROM THAT SHOWN ON CONTRACT DRAWINGS SHALL BE SUBMITTED FOR APPROVAL
ALL FUNCTIONAL REQUIREMENTS SHOWN ON DRAWING. SHOP DRAWINGS OF THE ACTUAL PROPOSED CONTROL
4. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE AND WORKABLE CONTROL SYSTEM TO SATISFY
SUBMITTED TO THE CONTRACTING OFFICER FOR APPROAL.
SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND
3. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS
BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER.
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED
COMMENCING ANY CONSTRUCTION OR RENOVATION.
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO
GENERAL NOTES & SCOPE OF WORKS
THE TEMPORARY COOLING OR HEATING SYSTEM TO THE ENTIRE BUILDING.
13. IF THE CONTRACTOR IS GOING TO CONSTRUCTION DURING THE COOLING/HEATING SEASON, THE CONTRACTOR SHALL PROVIDE
EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.
12. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, CERTIFIED INSTALLER.
11. INSTALLATION OF THE HVAC SYSTEM SHALL BE IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION BY A LICENSED OR
NECESSARY ACCESSORIES FOR HVAC CONTROLS.
10. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, CONDUITS AND ALL
9. ALL WIRING AND CONDUIT SYSTEMS FOR HVAC CONTROLS SHALL BE BY MECHANICAL/CONTROLS CONTRACTOR.
LOCATED AT LEAST 3 METERS (10 FEET) ABOVE THE GROUND.
8. ALL OUTSIDE AIR INTAKES TO HVAC SYSTEMS THAT ARE DESIGNED TO MOVE AIR THROUGHOUT THE BUILDING SHALL BE
ARCHITECT BEFORE FINAL INSTALLATION. MOUNTING HEIGHT SHALL BE AT 1.5M ABOVE FINISH FLOOR.
7. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH THE DESIGN
DRAWINGS FOR CEILING TYPES.
6. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER TO ARCHITECTURAL
FOR VIBRATION ISOLATION.
5. ALL EQUIPMENT CONNECTIONS TO DUCTWORK SHALL HAVE A MIN. OF 100MM OF REINFORCED CANVAS FLEXIBLE DUCTWORK
4. CONTRACTOR TO ALLOW AND PROVIDE FOR METAL DUCTWORK TRANSITIONS BETWEEN ALL EQUIPMENT AND DUCT CONNECTIONS.
TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.
3. PROVIDE CONCEALED DAMPER REGULATORS FOR ALL VOLUME DAMPERS OVER INACCESSIBLE CEILINGS AND SOFFITS. REFER
OBTAIN "TOTAL DUCT SIZE".
2. ALL DUCTWORK SIZES ARE SHOWN AS INSIDE CLEAR. ADD APPROPRIATE DIMENSIONS FOR INSULATION OR DUCT LINER TO
CONTROL WORK. CONTACT INFORMATION OF JCI IS 02-2027-4006 / WWW.JOHNSONCONTROLS.KR
CONTRACTOR SHALL PERFORM THE CONTRACTUAL WORK WITH JCI'S SERVICE TEAM FOR REPLACE AND RE-COMMISSIONING OF
INSTALLED AND OPERATED BY JCI UNDER ENERGY SAVINGS PERFORMANCE CONTRACT (ESPC) AND ARE JCI'S PROPERTIES.
CONTRACTOR SHALL VERIFY EXISTING CONDITION, AND COORDINATE WITH JCI AND K-16 DPW. DDC CONTROL SYSTEM WERE
WITH THE EXISTING SYSTEM. PRIOR TO REPLACING EXISTING H.V.A.C SYSTEM AS SHOWN ON THE DRAWING, MATOC
1. CONTROL WORK MUST BE PERFORMED BY THE JOHNSON CONTROLS INC.(JCI), AND ALL CONTROL WORK SHOULD BE CONNECTED
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
REPLACEMENT, AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON DRAWINGS. (PUMP ROOM)
9. REPLACE DETERIORATED EXISTING SWIMMING POOL HEATER AND SAND FILTERS, CONTROL WORK RELATED TO EQUIPMENT
8. REPLACE EXISTING SPRINKLER HEADS, AND ALL ASSOCIATED ACCESSORIES WHERE THE CEILING IS REPLACED.
AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON DRAWINGS.
HOT WATER PIPING SYSTEM, SEWER AND VENT PIPING SYSTEM INCLUDING PLUMBING FIXTURES, ELECTRIC WATER COOLERS,
7. REPAIR DETERIORATED EXISTING PLUMBING SYSTEM BY INSTALLING DOMESTIC HOT WATER HEATER, DOMESTIC COLD AND
FOR PLUMBING SYSTEM AS SHOWN ON DRAWINGS.
AND VENT PIPING SYSTEM INCLUDING PLUMBING FIXTURES, ELECTRIC WATER COOLERS, AND ALL ASSOCIATED ACCESSORIES,
6. REMOVE DETERIORATED EXISTING DOMESTIC HOT WATER HEATER, DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER
VERIFY IF THE HVAC SYSTEM WORKS PROPERLY.
5. PERFORM DALT (DUCT AIR LEAKAGE TEST) AND T.A.B (TESTING, ADJUSTING, AND BALANCING) AFTER CONSTRUCTION TO
ASSOCIATED ACCESSORIES AS SHOWN ON DRAWINGS.
4. REPAIR DETERIORATED VENTILATION SYSTEM BY INSTALLING ROOF EXHAUST FAN, DAMPER, DUCT, CONTROL WORK AND ALL
IN ENGLISH.
PAD, AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON DRAWINGS. REMOTE CONTROLLER INDICATORS AND LABELS SHALL BE
VENTILATORS, CONTROLLER, CO2 SENSOR, DIFFUSERS, DAMPERS, DUCTS, INSULATIONS, PIPE LINES, CONTROL WORK, CONC.
3. REPAIR DETERIORATED EXISTING HVAC SYSTEM BY INSTALLING NEW DUCT-FREE SPLIT HEAT PUMP UNITS, ENERGY RECOVERY
AND AIR CONDITIONING SYSTEM) AS SHOWN ON DRAWINGS.
THERMOSTATS, CONTROL WORK, CONC. PAD AND ALL ASSOCIATED ACCESSORIES, FOR HVAC SYSTEM (HEATING, VENTILATING
ELECTRIC WALL HEATER, ROOF EXHAUST FANS, DAMPERS, VALVES, DUCTS, PIPES, INSULATIONS, DIFFUSERS, CONTROLLERS,
2. REPAIR DETERIORATED EXISTING HVAC SYSTEM BY INSTALLING NEW AIR HADNLING UNIT, AIR COOLED CONDENSING UNIT.
ACCESSORIES, FOR HVAC SYSTEM (HEATING, VENTILATING AND AIR CONDITIONING SYSTEM) AS SHOWN ON DRAWINGS.
PIPES, INSULATIONS, DIFFUSERS, CONTROLLERS, THERMOSTATS, CONTROL WORK, CONC. PAD AND ALL ASSOCIATED
A/C OUTDOOR & INDOOR UNITS, FINNED TUBE RADIATORS, ROOF EXHAUST FANS, DAMPERS, LOUVERS, VALVES, DUCTS,
1. REMOVE DETERIORATED EXISTING AIR HADNLING UNIT, AIR COOLED CONDENSING UNIT. HEATING & VENTILATING UNIT, HP
DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
: 208 V, 1 PH, 60 Hz
: 1,800 W (6,100 BTU/HR)
: 1,600 W (5,500 BTU/HR)
MFR. LG MODEL NO. ARNU053SBL4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
CONTROLLER AND ALL NECESSARY APPURTENANCES. UL-LISTED.
COMPLETE WITH BUILT-IN CONTROLS, LOW AMBIENT TEMPERATURE CONTROL, WIRELESS REMOTE
CENTRIFUGAL FAN AND 3-SPEED FAN MOTORS. WASHABLE ANTIFUNGAL FINLER. UNIT SHALL BE
DUCT FREE MULTI-SPLIT SYSTEM WITH HIGH WALL MOUNTED, DIRECT EXPANSION INDOOR UNITS.
DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)HP
UL-LISTED.
WIRELESS REMOTE CONTROLLER, HANGING BRACKETS, AND ALL NECESSARY ACCESSORIES.
OPTIMUM ROOM TEMPERATURE DURING SEASON CHANGES, WALL MOUNTED WIRE CONTROLLER,
CLEANABLE FILTERS, AUTOMATICALLY SWITCHES TO COOLING-OR HEATING-MODE TO MAINTAIN THE
INVERTER MOTOR, CONDENSATE PUMP SYSTEM, ADJUSTABLE AIR LOUVERS FOR 4-WAY DISCHARGE, UNIT. COMPLETE WITH COOLING / HEATING COIL, TURBO FAN, TOTAL VIRUS FILTER, BLDC
IN-THE-CEILING MOUNTED, DIRECT-EXPANSION FAN COIL TO MATCHED WITH HEAT PUMP OUTDOOR
: 208 V, 1 PH, 60 Hz
: 2,500 W (8,500 BTU/HR)
: 2,200 W (7,500 BTU/HR)
MFR. LG MODEL NO. ARNU073TRC4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
HP
2 DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
HP
SAME AS ABOVE ITEM NO. EXCEPT
MFR. LG MODEL NO. ARNU123TRC4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
: 208 V, 1 PH, 60 Hz
: 4,000 W (13,600 BTU/HR)
: 3,600 W (12,300 BTU/HR)
HP
2 DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
HP
SAME AS ABOVE ITEM NO. EXCEPT
MFR. LG MODEL NO. ARNU183TNA4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
: 208 V, 1 PH, 60 Hz
: 6,300 W (21,500 BTU/HR)
: 5,600 W (19,100 BTU/HR)
HP
4 DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
HP
SAME AS ABOVE ITEM NO. EXCEPT
MFR. LG MODEL NO. ARNU123TNA4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
: 208 V, 1 PH, 60 Hz
: 4,000 W (13,600 BTU/HR)
: 3,600 W (12,300 BTU/HR)
HP
1 DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
HP
SAME AS ABOVE ITEM NO. EXCEPT
MFR. LG MODEL NO. ARNU093TRC4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
: 208 V, 1 PH, 60 Hz
: 3,200 W (10,900 BTU/HR)
: 2,800 W (9,600 BTU/HR)
KIM, SM
MECHANICAL
2 18 M-2
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
188985
E Q U I P M E N T S C H E D U L E S - 1
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
EQUIPMENT SCHEDULES - 1
QTYITEM D E S C R I P T I O N QTYITEM D E S C R I P T I O N
AHU
AIR HANDLING UNIT
MFR. CARRIER MODEL NO. 40RUA16 OR APPROVED EQUAL.
: 3.7 HP, 208/230 V, 3 Ph, 60 Hz
: 6,000 CFM @ 10 STATIC PRESSURE
: 23.4°CDB
: 17.9°CDB
: 120,000 BTU/HR
: 15.2°CDB 14.5°CWB
: 26.3°CDB 20.1°CWB
: 4 ROWS
: 17.67 SQ FT
: 180,000 BTU/HR
FAN MOTOR
FAN CAPACITY
LVG. AIR TEMP.
ENT. AIR TEMP.
TOTAL CAPACITY
HEATING COIL
LVG. AIR TEMP.
ENT. AIR TEMP.
NUMBER OF ROWS
FACE AREA
TOTAL CAPACITY
DX-COOLING COIL
UL/ETL-LISTED.
FILTERS, REFRIGERANT R-410A, ALL NECESSARY SAFETIES & OPERATING ACCESSORIES.
HOUSING & CONDENSATE DRAIN PAN, CONDENSATE DRAIN OVERFLOW SHUTOFF SWITCH, AIR
COIL SECTION AND DIRECT EXPANSION COOLING COIL SECTION, CENTRIFUGAL FAN, INSULATED
STEEL CASING, SEPARATED FAN & COIL SECTIONS, AND EQUIPPED WITH HOT WATER HEATING
HORIZONTAL DRAW THRU TYPE, INDOOR MOUNTED, FACTORY ASSEMBLED, DIE-FORMED GALVANIZED
1 AIR COOLED CONDENSING UNITACU
RATING
QTY
CONDENSER FANS
RATING
QTY
COMPRESSORS
AMBIENT TEMP.
SUCTION TEMP.
REF. CAPACITY
(EACH)
: 1/4 HP, 208/230 VOLTS, 3 PH, 60 Hz
: 3 EA
(TOTAL)
: 16.4 kW, 208/230 VOLTS, 3 PH, 60 Hz
: 2 EA
: 95°F(35°C) DB
: 45°F(7°C) DB
: 52.8 kW (15 TONS)
MFR. CARRIER MODEL NO. 38AUD16 OR APPROVED EQUAL.
UL/ETL-LISTED.
OPERATION DOWN TO -20°F(-29°C), ALL NECESSARY SAFETIES & OPERATING ACCESSORIES.
ISOLATION, COMFORT ALERT CONTROL SYSTEM, LOW AMBIENT CONTROLS WHICH PROVIDE COOLING
CONDENSER FAN, ROUND TUBE PLATE FIN COILS, FILTER DRIER AND A SIGHT GLASS, VIBRATION
REFRIGERANT R-410A, A/C SCROLL COMPRESSOR, CRANKCASE HEATER, 3EA MOTOR DRIVE TYPE
FLOOR MOUNTED, DUAL CIRCUIT, FACTORY ASSEMBLED, PREPAINTED GALVANIZED STEEL CABINET, DUCT-FREE SPLIT HEAT PUMP SYSTEM (OUTDOOR UNIT)2
HPO
ACCESSORIES. ETL LISTED.
CHARGE, VIBRATION ISOLATORS, CONTROL SYSTEM, AND ALL NECESSARY SAFETIES & OPERATING
AIR-COOLED COIL, FAN(S) & MOTOR(S), REFRIGERATION COMPONENTS, R-410A REFRIGERANT
AND HEATING SYSTEM. HEATING MULTI SYSTEM, CONSISTING OF DC INVERTER COMPRESSOR(S), WEATHER-PROOF, UNIT SHALL FUNCTION AS THE OUTDOOR COMPONENT OF AIR-TO-AIR COOLING
CONTROL
REFRIGERANT
SOUND PRESSURE
EFFICIENCY
ELECTRICAL RATING
QUANTITY / TYPE
COMPRESSOR
HEATING CAPACITY
COOLING CAPACITY
OUTDOOR UNIT
MFR. LG MODEL NO. ARUM121BTE5 OR APPROVED EQUAL.
: ELECTRONIC EXPANSION VALVE (EEV)
: R410A
: 59.0 dB
208 VOLTS, 3 Ph, 60 Hz
60 AMP MOCP
: 40.3 AMP MCA
: 1 / HSS SC SCROLL
: 39,600 W (135,000 BTU/HR)
: 35,100 W (120,000 BTU/HR)
1 601
EF
62156 115
1 601
EF
62227 115
KIM, SM
MECHANICAL
3 18 M-3
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
188985
E Q U I P M E N T S C H E D U L E S - 2
QTYITEM D E S C R I P T I O N QTYITEM D E S C R I P T I O N
K-16
AND INDOOR SWIMMING POOL
REPAIR DETERIORATED GYM. FACILITY
FY18
HP
1 DUCT-FREE SPLIT HEAT PUMP SYSTEM (INDOOR UNIT)
HP
SAME AS ABOVE ITEM NO. EXCEPT
MFR. LG MODEL NO. ARNU243TNA4 OR APPROVED EQUAL.
ELECTRIC POWER INPUT
HEATING CAPACITY
COOLING CAPACITY
: 208 V, 1 PH, 60 Hz
: 8,000 W (27,300 BTU/HR)
: 7,100 W (24,200 BTU/HR)
1 ENERGY RECOVERY VENTILATORERV
COMPLETE WITH ALL NECESSARY SAFETIES AND OPERATING ACCESSORIES.
MOUNTED WIRE CONTROLLER, WALL MOUNTED WIRE CO2 SENSOR, HANGING VIBRATION ISOLATORS, MOTORIZED DAMPER ON EXHAUST AIR STREAM. BYPASS MODE W/ DAMPER, FILTERS, WALL
DEFROST CYCLE FEATURES, EQUIPPED WITH MOTORIZED DAMPER ON OUTDOOR AIR STREAM AND
OUTDOOR AIR STREAM, 3-SPEED SUPPLY FAN AND 3-SPEED EXHAUST FAN, CONTROLS, AUTOMATIC
COUNTERFLOW ENTHALPHIC HEAT EXCHANGER, NO MIXING OF STALE AIR STREAM WITH THE FRESH
FACTORY ASSEMBLED, ACOUSTICAL DESIGN, INSTALLATION FLEXIBILITY, CROSSFLOW OR
: 0.23 Kw, 208-230 V, 1 PH, 60 Hz
: 188 CFM @ 0.20 WG.ESP.
: 294 CFM @ 0.40 WG.ESP.
: 294 CFM @ 0.60 WG.ESP.
ELECTRIC POWER INPUT
LOW
MEDIUM
HIGH
FAN CAPACITY
1 ENERGY RECOVERY VENTILATORERV
SAME AS ABOVE ITEM NO. EXCEPT
ERV
ELECTRIC POWER INPUT
LOW
MEDIUM
HIGH
FAN CAPACITY
: 0.47 Kw, 208-230 V, 1 PH, 60 Hz
: 471 CFM @ 0.20 WG.ESP.
: 589 CFM @ 0.36 WG.ESP.
: 589 CFM @ 0.64 WG.ESP.
APPROVED EQUAL.
MFR. LG MODEL NO. ARVU063ZEA2, PQRCVSL0 (CONTROLLER), PES-C0RV0 (CO2 SENSOR) OR
5 ELECTRIC WATER COOLER
COOLING UNIT, WATER FILTER, CONFORMING TO ARI STANDARD 1010.
RECIPROCATING TYPE COMPRESSOR, AIR-COOLED TYPE CONDENSER, COMBINATION TUBE-TANK
FLOOR MOUNTED, MECH./ELECTRICALLY REFRIGERATED UNIT, HERMETICALLY SEALED
COMPRESSOR RATING
CAPACITY
MFR. ELKAY MODEL LFDE10 OR APPROVED EQUAL.
EWC
: 535 W, 115 V, 1 PH, 60 Hz
ROOF EXHAUST FAN
V PH Hz
REMARKS
1 60115
1 601
EF
EF
1/12
MOTOR SIZE
HP
(LPS)
CAP
(Pa)
ESP
62180 1,050
62 1,300 115
1 601
EF
62 1,300 115
1 601
EF
283 115
RPM
FAN
HOUSING, BACKDRAFT DAMPER, BIRDSCREEN AND DISCONNECT SWITCH.
ROOF MOUNTED CENTRIFUGAL TYPE, DIRECT DRIVE COMPLETE WITH WEATHERPROOF ALUMINUM
MFR. GREENHECK MODEL G-095E OR APPROVED EQUAL.
LATRINE 124
1/30
MFR. GREENHECK MODEL G-095E OR APPROVED EQUAL.
LATRINE 113, BREAK RM 114
MFR. GREENHECK MODEL G-095G OR APPROVED EQUAL.
CORRIDOR 104
MFR. GREENHECK MODEL G-095G OR APPROVED EQUAL.
SHOWER 122
1/1262 1,300
MFR. GREENHECK MODEL G-095G OR APPROVED EQUAL.
CORRIDOR 104
1,050 1/30
1,150 1/20
MFR. GREENHECK MODEL G-095VG OR APPROVED EQUAL.
SHOWER 127
APPROVED EQUAL.
MFR. LG MODEL NO. LZ-H504SB, PQRCVSL0 (CONTROLLER), PES-C0RV0 (CO2 SENSOR) OR
MFR. BROAN MODEL NO. 192 OR APPROVED EQUAL.
EH
ELECTRIC WALL HEATER
STANDARD ACCESSORIES.
CHROMIUM ELECTRIC HEATING ELEMENT, RCED-AIR HEATER, EQUIPPED WITH MANUFACTURE
BLOWER. GALVANIZED STEEL HOUSING AND WHITE COLOR POLYMERIC GRILLE FINISHED, NICKEL
BUILT-IN ADJUSTABLE THERMOSTAT. THERMALLY PROTECTED MOTOR AND TRANSVERSE FLOW
ACTION CIRCULATES AND HEAT RESISTANT. OVER TEMPERATURE PROTECTED BY THERMAL FUSE.
UL LISTED, CUT A HOLE IN A WALL TO FLUSH MOUNTING TYPE. QUIET FAN AND DOWN FLOW
ELECTRIC POWER INPUT
HEATING CAPACITY
: 4.1 Amp, 240 V, 1 PH, 60 Hz
: 1,000 W (3,413 BTU/HR)
1/12
EQUIPMENT SCHEDULES - 2
DWH DOMESTIC HOT WATER HEATER
MFR. BOCK MODEL 250-1500 OR APPROVED EQUAL.
& FULLY AUTOMATIC OPERATION CONTROL, 150 PSI WORKING PRESSURE. UL-LISTED.
INTEGRATED STEEL SKID, GAS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.