191107
KIM, SM
MECHANICAL
33 66 M-12
NTS
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
M12 NOT TO SCALE
20,80
Cv=25.00
Cv=17.30
Cv=2.12 (TYP)
32,80
80,25
32,80
80,25
20,80
80,15
80,15
25,8025
32,80
80,40
65,50
50,65
65,50
40,65
80,40
(TYP OF 82)
EXISTING FAN COIL UNIT
REMOVE AND REINSTALL
(TYP)
AUTO AIR VENT
(TYP)
EXPANSION LOOP
(TYP)
PIPE GUIDE
(TYP)
PIPE ANCHOR
CONTROL VALVE (TYP)
THERMOSTATIC
RADIATOR (TYP)
FINNED TUBE
(TYPICAL)
UNIT HEATER
(TYP OF 2)
AIR HANDLING UNIT
AUTO AIR VENT (TYP)
Cv=16.00
Cv=28.30
NEW H.V.A.C PIPING ISOMETRIC DIAGRAM
NEW H.V.A.C PIPING ISOMETRIC DIAGRAM
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
RD
RD
RD
AH
AH
UH
UH
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
FC
P.O.C
15 15
CH/
HWR CH/
HWSCH/HWS
CH/HWR
CH/HWS
CH/HWR
CH/HWS
CH/HWR
CH/
HWR
CH/HWR
CH/HWS
80,25
50,65
MECHANICAL
34 66 M-13
NTS
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
CONTROLS - 1
TH TC
SIZE
ƒ 9.2
1‚
1•
2•
3 120
Cv
TACO
5.3
14.2
24.8
4 460
6 640
8 1140
CS
CEILING MOUNTED
DP
DIFFERENTIAL PRESSURE GAUGE
HI
MED
LO
OFF
TC
TH
M
120 VAC
NOT TO SCALE
CONTROL DESCRIPTION
SUPPLY FAN CONTROL
M
F
LADDER DIAGRAM
MD-2
HEATING CONTROL
MD-1
COOLING CONTROL
THTC
AH
1HVAC CONTROL SCHEMATIC DIAGRAM
C
H
C
DP
CS
C
F
OFF
OLS
C1
ON
120 VAC
MD-1
MD-2
TC
R
R
TH
R1
R2
OFF
AUTO
HAND
C
OL
C1
EXHAUST FAN (EF-1)
AH
SWITCH
"ON-OFF"
C H
H W
R
C H
H W
S
SUPPLY AIR
FREEZESTAT
NOT TO SCALE
OUTSIDE AIR
FAN
UNIT SUPPLY
AIR HANDLING
DAMPER
MOTORIZED
OUTSIDE AIR
DAMPER
BY-PASS
FACE AND
COOLING
HEATING
FAN
EXHAUST
ROOF
BY-PASS DAMPER
FACE AND
WHEN THE SUPPLY FAN IS NOT OPERATING.
3. OUTSIDE AIR MOTORIZED DAMPER MD-1 RETURNS TO CLOSE POSITION
AIR TEMPERATURE DROPS TO 40°F OR LOWER.
2. FREEZESTAT F STOPS THE SUPPLY FAN OPERATION WHEN THE MIXED
SUPPLY FAN.
1. "ON-OFF" FAN SELECTOR SWITCH TO "ON" POSITION ENERGIZES THE
3. CHILLED WATER IS FULL FLOW THRU THE COOLING COIL.
THE COOLING SEASON.
DAMPER TO MAINTAIN THE SUPPLY AIR TEMPERATURE AT 75°F DURING
2. COOLING THERMOSTAT TC MODULATES THE FACE AND BY-PASS
TEMPERATURE IN THE PIPE.
HEATING AND COOLING THERMOSTAT DEPENDING ON THE FLUID
1. CHANGEOVER SWITCH CS CONTROLS THE CHANGEOVER BETWEEN THE
3. HOT WATER IS FULL FLOW THRU THE HEATING COIL.
HEATING SEASON.
TO MAINTAIN THE SUPPLY AIR TEMPERATURE AT 82°F DURING THE
2. HEATING THERMOSTAT TH MODULATES THE FACE AND BY-PASS DAMPER
1. CHANGEOVER SWITCH CS CONTROLS THE CHANGEOVER BETWEEN THE
AND RUNS WHEN THE AIR HANDLING UNITS ARE OPERATING.
3. EXHAUST FANS ARE ELECTRICALLY INTERLOCKED WITH AIR HANDLING UNITS
EXHAUST FAN.
2. "HAND-OFF-AUTO" SELECTOR SWITCH TO "AUTO" POSITION ENERGIZES THE
FAN CONTINUOUSLY UNTIL MANUALLY STOPPED.
1. "HAND-OFF-AUTO" SELECTOR SWITCH TO "HAND" POSITION RUNS THE EXHAUST
SWITCH
CHANGEOVER
AUTO
SUPPLY
SWITCH
CHANGEOVER
AUTO
FAN COIL UNIT CONTROL (LAUNDRY)
SUPPLY AIR
SET-POINT : 75°F
COOLING THERMOSTAT
SET-POINT : 68°F
HEATING THERMOSTAT
COIL
HEATING/COOLING
COMBINATIONSUPPLY FAN
CH/HWS
CH/HWR
RETURN AIR
SETTER
CIRCUIT
SWICTH
AUTO CHANGEOVER
FAN
TYPICAL FAN COIL UNIT CONTROL
CS
SIZE
ƒ9.2
1‚
1•
2•
Cv
TACO
5.3
14.2
24.8
81140
TH TCTS
TC
TH
TS
CONTROL DESCRIPTION
DESCRIPTION OF CONTROL COMPONENTS
SYMBOL D E S C R I P T I O N
MOTORIZED VOLUME DAMPER
MD-1
STROKE
VOLTAGE : 120 VAC
DAMPER
OPPOSED BLADES TYPE, ALUMINUM CONSTRUCTION.
ACTUATOR
SPRING RETURN CLOSED ON POWER INTERRUPTION.
ELECTRIC TWO POSITION TYPE, NORMALLY CLOSED WITH
: 0 - 90
MOTORIZED VOLUME DAMPER
MD-2
STROKE
VOLTAGE : 120 VAC
DAMPER
OPPOSED BLADES TYPE, ALUMINUM CONSTRUCTION.
ACTUATOR
SPRING RETURN CLOSED ON POWER INTERRUPTION.
ELECTRIC PROPORTIONAL TYPE, NORMALLY CLOSED WITH
: 0 - 90
FREEZESTAT
F
SET POINT
VOLTAGE
: 40°F
: 120 VAC
COOLING THERMOSTAT
TC
SET POINT
TEMP. RANGE
VOLTAGE
: 75°F
: 55°F TO 78°F
: 120 VAC
HEATING THERMOSTAT
TH
SET POINT
TEMP. RANGE
VOLTAGE
: 82°F
: 55°F TO 85°F
: 120 VAC
CAPILLARY HOLDER FOR HOLDING BULB ON DUCT.
BREAKS CONTACT ON TEMPERATURE DROP, MANUAL RESET AND
WALL MOUNTED, WITH REMOTE SENSING BULB, SPST SWITCH
FOR HOLDING BULB ON DUCT.
AVERAGING TYPE SENSING ELEMENT AND CAPILLARY HOLDER
DUCT MOUNTED, PROPORTIONAL TYPE WITH REMOTE
FOR HOLDING BULB ON DUCT.
AVERAGING TYPE SENSING ELEMENT AND CAPILLARY HOLDER
DUCT MOUNTED, PROPORTIONAL TYPE WITH REMOTE
TC
COOLING THERMOSTAT (FAN COIL UNITS)
SET POINT
TEMP. RANGE
VOLTAGE
TEMPERATURE DROP.
SENSING ELEMENT, SPDT SWITCH BREAKS CONTACT ON
WALL MOUNTED,"0N-OFF" TYPE WITH FAST RESPONSE
: 75°F
: 55°F TO 85°F
: 120 VAC
HEATING THERMOSTAT (FAN COIL UNITS)
TH
TS
SET POINT
TEMP. RANGE
VOLTAGE
TEMPERATURE RISE.
SENSING ELEMENT, SPDT SWITCH BREAKS CONTACT ON
WALL MOUNTED,"0N-OFF" TYPE WITH FAST RESPONSE
AUTO CHANGEOVER SWITCH
CS
: 120 VAC
: 50°F
PIPE MOUNTED ELECTRIC TYPE WITH SPDT SWITCH.
VOLTAGE
SET POINT
55°F (TS) / : 68°F (TH)
: 55°F TO 85°F
: 120 VAC
STATIC PRESSURE TIPS AND ALL NECESSARY ACCESSORIES.
AND GRADUATIONS COMPLETE WITH MOUNTING BRACKETS,
HAVE 2-1/16 INCH DIA. WHITE DIAL WITH BLACK FIGURES
DIAPHRAGM ACTUATED WITH POINTER ZERO ADJUSTMENT AND
MINOR DIVISIONS
RANGE
INSIDE DUCT.DUCT MOUNTED ELECTRICAL SWITCH OPERATED BY SAIL
: 0.20" WG
: 0.20" WG TO 2.0"WG
TEMPERATURE IN THE PIPE.
CHANGEOVER SWITCH CS CONTROLS THE CHANGEOVER BETWEEN THE
AT 68°F DURING THE HEATING SEASON.
IN AN "ON-OFF" SEQUENCE TO MAINTAIN THE ROOM TEMPERATURE
HEATING THERMOSTAT TH CONTROLS THE SUPPLY FAN OPERATION
AT 75°F DURING THE COOLING SEASON.
IN AN "ON-OFF" SEQUENCE TO MAINTAIN THE ROOM TEMPERATURE
COOLING THERMOSTAT TC CONTROLS THE SUPPLY FAN OPERATION
STOPPED OR STOPPED BY THE HEATING OR COOLING THERMOSTAT.
RUNS THE FAN COIL UNIT SUPPLY FAN CONTINUOUSLY UNTIL MANUALLY
"HI-MED-LO-OFF" SELECTOR SWITCH TO "HI", "MED" OR "LOW" POSITION
SELECTOR SWITCH.
FAN SPEED WILL BE CONTROLLED MANUALLY THRU THE "HI-MED-LO-OFF"
5.
4.
3.
2.
1.
WHEN THE ROOM IS UNOCCUPIED.
IN AN "ON-OFF" SEQUENCE TO MAINTAIN THE ROOM TEMPERATURE AT 55°F
SET-BACK THERMOSTAT TS CONTROLS THE SUPPLY FAN OPERATION
CHANGEOVER SWITCH CS CONTROLS THE CHANGEOVER BETWEEN THE
DURING THE HEATING SEASON.
AN "ON-OFF" SEQUENCE TO MAINTAIN THE ROOM TEMPERATURE AT 68°F
HEATING THERMOSTAT TH CONTROLS THE SUPPLY FAN OPERATION IN
DURING THE COOLING SEASON.
AN "ON-OFF" SEQUENCE TO MAINTAIN THE ROOM TEMPERATURE AT 75°F
COOLING THERMOSTAT TC CONTROLS THE SUPPLY FAN OPERATION IN
STOPPED OR STOPPED BY THE HEATING OR COOLING THERMOSTAT.
RUNS THE FAN COIL UNIT SUPPLY FAN CONTINUOUSLY UNTIL MANUALLY
"HI-MED-LO-OFF" SELECTOR SWITCH TO "HI", "MED" OR "LOW" POSITION
SELECTOR SWITCH.
FAN SPEED WILL BE CONTROLLED MANUALLY THRU THE "HI-MED-LO-OFF"
6.
5.
4.
OFF
LO
MED
HI
CORKEY INTERFACE
120 VAC
SUPPLY
FAN
M
R
CHANGEOVER SWITCH
AUTO
SUPPLY FAN
CH/HWS
AUTO CHANGEOVER SWITCH
CH/HWR
CIRCUIT SETTER
COIL
HEATING/COOLING
COMBINATION
SET-POINT : 55°F
SETBACK THERMOSTAT
NOT TO SCALE
SET-POINT: 75°F
COOLING THERMOSTAT
SET-POINT: 68°F
HEATING THERMOSTAT
LADDER DIAGRAM
LADDER DIAGRAM
EF
EF
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
HWR
HWS
AAV
UNIT HEATER
NOT TO SCALE
T
ROOM THERMOSTAT
T
OFF
HAND
C
OL
M
MD
TF
ROOF EXHAUST FAN CONTROL
EF
ROOF EXHAUST FAN CONTROL
EF
TF
ROOM THERMOSTAT
TTHW
TANK MOUNTED THERMOSTAT
M
EF
EF
EF
191107
KIM, SM
MECHANICAL
35 66 M-14
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
CONTROLS - 2
WINDOW OCC.SENSOR
FAN COIL UNIT
F.C.U APPLICATION DIAGRAM
CONTROLLER
FCU
7.5 WATT
DRY CONTACT,
SWITCH, N.O,
WINDOW STATUS SWITCH
"H-O-A"
CIRCUIT SETTER
VALVE
GATE
HEATER
UNIT
PIPE CAP
LADDER DIAGRAM
LADDER DIAGRAM
THE EXHAUST FAN CONTINUOUSLY UNTIL MANUALLY STOPPED
"HAND-OFF-AUTO" SELECTOR SWITCH TO "HAND" POSITION RUNS
NOT TO SCALE
SWITCH
"H-O-A"
120 VAC
FAN
EXHAUST
ROOF
FAN
EXHAUST
ROOF
OFF
AUTO
HAND
C
OL
MD
120 VAC
TF
FAN
EXHAUST
ROOF
C1
(FOR EF-4 & 6 ONLY)
VOLUME DAMPER
MOTORIZED
AND OPENS TO OUTSIDE AIR WHEN THE EXHAUST FAN IS OPERATING.
4. MOTORIZED VOLUME DAMPER MD IS ELECTRICALLY INTERLOCKED WITH THE EXHAUST FAN
80°F.
85°F OR HIGHER AND STOPS THE EXHAUST FAN WHEN THE ROOM TEMPERATURE DROPS TO
3. ROOM THERMOSTAT TF RUNS THE EXHAUST FAN WHEN THE ROOM TEMPERATURE REACHES
2. "HAND-OFF-AUTO" SELECTOR SWITCH TO "AUTO" POSITION ENERGIZES THE EXHAUST FAN.
CONTINUOUSLY UNTIL MANUALLY STOPPED.
1. "HAND-OFF-AUTO" SELECTOR SWITCH TO "HAND" POSITION RUNS THE EXHAUST FAN
(FOR EF-4 & 6 ONLY)
POWER INTERRUPTION
RETURN, CLOSED ON
DAMPER WITH SPRING
OUTSIDE AIR MOTORIZED
SWITCH
"H-O-A"
NOT TO SCALE
DESCRIPTION OF CONTROL COMPONENTS
SYMBOL D E S C R I P T I O N
SET-POINT
INPUT VOLTAGE
: 50°F
: 120 VAC
CONTACT ON TEMPERATURE DROP.
WALL MOUNTED WITH FAST RESPONSE HYDRAULIC ELEMENT AND SPST SWITCH BREAKS
CONTACT ON TEMPERATURE DROP.
WALL MOUNTED WITH SPDT SWITCH MAKES CONTACT ON TEMPERATURE RISE, BREAKS
RANGE
INPUT VOLTAGE
: 55°F TO 85°F
: 120 VAC
CONTACT ON TEMPERATURE DROP.
TANK MOUNTED WITH SPDT SWITCH BREAKS CONTACT ON TEMPERATURE RISE, MAKES
SET POINT
INPUT VOLTAGE
: 140°F
: 120 VAC
DURING OCCUPIED PERIOD.
IN AN "ON-OFF" SEQUENCE TO MAINTAIN THE ROOM TEMPERATURE AT 50°F
3. ROOM THERMOSTAT T CONTROLS THE UNIT HEATER SUPPLY FAN OPERATION
THE UNIT HEATER SUPPLY FAN.
2. "HAND-OFF-AUTO" SELECTOR SWITCH TO "AUTO" POSITION, ENERGIZES
UNIT HEATER SUPPLY FAN CONTINUOUSLY UNTIL MANUALLY STOPPED.
1. "HAND-OFF-AUTO" SELECTOR SWITCH TO "HAND" POSITION RUNS THE
P-1
MECHANICAL
36 66 M-15
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
SCALE: 1:100
0 2000 4000
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
N
SCALE = 1:100M15
RISERS FROM 2ND FLOOR
15mm DCW & DHWS PIPE RISERS FROM 2nd FLOOR (TYP)
32mm DHWS, 40mm DCW PIPE
RISERS FROM 2nd FLOOR
20mm DHW & DHWS PIPE
FROM 2nd FLOOR
15mm DHWR PIPE RISER
3 2
SEE DWG
ENLARGED PLAN
FOR SIMILAR
SEE DWG
PARTIAL PLAN
FOR ENLARGED
P-5
P-1
P-7
P-4 P-4
P-7
P-1
P-5 P-5P-5
P-1 P-1
P-4P-4
P-7P-7
AT 2nd & 3rd FLOORS ONLY (TYP)
32mm DHWS, 40mm DCW PIPE RISER
15 (TYP)
AT 1st & 2nd FLOORS ONLY (TYP)
32mm DHWS, 40mm DCW PIPE RISER
32, 40 (TYP)
(TYPICAL)
WATER HAMMER ARRESTERA
M15
SCALE = 1:50
PIPING ENLARGED PARTIAL PLAN
TYP BEDROOM DOMESTIC WATER
M15
SCALE = 1:50
PIPING ENLARGED PARTIAL PLAN
LAUNDRY RM DOMESTIC WATER
P-1 P-5
P-4
P-1
P-5
P-7
P-9
P-4
RISER FROM 2nd FLOOR
DOMESTIC WATER PIPE
A15
15 PIPES UP TO 2nd FLOOR
80mm DCW, 65mm DHWS
ARRESTER (TYP)
WATER HAMMER
D
W
W
W
W
W
D
D
D
W
MECH RM
LAUNDRY
UP
D
W
W
W
W
W
D
D
D
UP
W
BATH
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
WALKWAY
WALKWAY
WALKWAY
J.C
STAIR
STAIR
WALKWAY
DAY ROOM
MECH RM
LAUNDRY
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
SVC. AREA
SVC. AREA 126-1
RM
VALVE
COMM RM
AS SHOWN
NEW DOMESTIC WATER PIPING PLAN (1st FLOOR)
M15 M15
(1st FLOOR) & ENLARGED PARTIAL PLANS
NEW DOMESTIC WATER PIPING PLAN
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
MAY BE ADDED IN TH FUTURE)
FOR FUTURE WORK (KITCHEN SINK
ONLY COMPLETE THE BRANCH WORK
MAY BE ADDED IN TH FUTURE)
FOR FUTURE WORK (KITCHEN SINK
ONLY COMPLETE THE BRANCH WORK
FUTURE PLAN
B
C
A
PDI-WH 201 AND MANUFACTURER'S INSTRUCTIONS.
2. SIZE AND LOCATE WATER HAMMER ARRESTORS PER
CHAMBER W/EXPANSION BELLOWS.
1. COPPER CONSTRUCTION PRESSURIZED COMPRESSION
REMARKSCONNECTION
PIPE
RATING
FU
QTYSYMBOL
P.D.I
1-11
12-32 20
33-60 25-
PLUMBING FIXTURES SCHEDULE
PLUMBING FIXTURES QTY
COLD HOT TRAP VENT
REMARKS
15 15
LAVATORY
- INTEG.15
1LAUNDRY SINK
KITCHEN SINK 15 15 50 32
15 3250
LOCAL PIPE CONNECTION
50 3.8 LITERS/FLUSH
SYMBOL
SERVICE SINK 15 15 80 323
WASHING MACHINE
WATER CLOSET, FLUSH TANK
SHOWER MAX. 2.5 GPM @ 80 PSI
MAX. 0.5 GPM @ 60 PSI
MAX. 2.2 GPM @ 60 PSI
MAX. 2.2 GPM @ 60 PSI
MAX. 2.2 GPM @ 60 PSI
WATER HAMMER ARRESTER SCHEDULE
191107
KIM, SM
MECHANICAL
37 66 M-16
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
SCALE: 1:100
0 2000 4000
(2nd FLOOR)
NEW DOMESTIC WATER PIPING PLAN
GRAPHIC SCALE
N
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BALCONY
STAIR
STAIR
J.C
DAY ROOM
STORAGE
SVC. AREA
CLOSET
WALK-IN
CLOSET
WALK-IN
SVC. AREA CLOSET
WALK-IN
CLOSET
WALK-IN
UP
DN
WALKWAY
WALKWAY
BALCONY
CORR
UPDN
228-1
STORAGE
SCALE = 1:100M16
RISERS FROM 3rd FLOOR
20mm DCW & DHWS PIPE
RISER FROM 3rd FLOOR
15mm DHWR PIPE
RISERS DOWN TO 1st FLOOR
20mm DCW & DHWS PIPE
P-7
3rd FLOOR
PIPE RISERS FROM
15mm DCW & DHWS
TO 1st FLOOR
PIPE RISERS DOWN
15mm DCW & DHWS
SEE DWG
ENLARGED PLAN
FOR SIMILAR 3
P-1
P-4
P-5
P-7
P-9
P-8
M15
NEW DOMESTIC WATER PIPING PLAN (2nd FLOOR)
1:100
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
SCALE = 1:100M17
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
N
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BALCONY
STAIR
STAIR
J.C
DAY ROOM
STORAGE
SVC. AREA
SVC. AREA CLOSET
WALK-IN
CLOSET
WALK-IN
UP
DN
WALKWAY
WALKWAY
BALCONY
CORR
UPDN
228-1
STORAGE
191107
KIM, SM
MECHANICAL
38 66 M-17
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
(3rd FLOOR)
NEW DOMESTIC WATER PIPING PLAN
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
P-7
A
ARRESTER (TYP)
WATER HAMMER
TO 2nd FLOOR
PIPE RISERS DOWN
15mm DCW & DHWS
AIR VENT (TYP)
AUTOMATIC
A
ARRESTER (TYP)
WATER HAMMER
RISERS DOWN TO 2nd FLOOR
20mm DCW & DHWS PIPE
DOWN TO 2nd FLOOR
15mm DHWR PIPE RISER
15,20,20 40,32 (TYP)
SEE DWG
ENLARGED PLAN
FOR SIMILAR 3
3150 49784
28452946 2845 2845 2845 2845
3658 1981
5690 5690 5690 5690 5690 5690 8026
28452845 2845 2845 2845 3048 1829
C D E F G H J KA-6 B LK-4A
RISERS DOWN TO 2nd FLOOR (TYP)
40mm DCW & 32mm DHWS PIPE
M15
NEW DOMESTIC WATER PIPING PLAN (3rd FLOOR)
1:100
MECHANICAL
39 66 M-18
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
M18 NOT TO SCALE
,4
,8
(TYP)
Cv =2 .1
CI
RCUI
T
SETTER
ARRESTER
(TYP)
WATER
HAMMER
FOR
DETAI
L, S
EE
WASHER
BOX
(TYP
OF
6)
AI
R
VENT
(TYP)
AUTOMATI
C
,3
,4
,4
,8
,3
,4
,4
,8
,3
,3
,4
,4
,3
,4
,3
,4
,3
,4
,3
,3
,3
2 40 ,5
,3
,4
PI
PE
GUI
DE
(TYP)
PI
PE
ANCHOR
(TYP)
,6
,5
,3
,3
,3
,4
,3
,4
,3
,4
,3
,4
0 15
,5
,5
,4
,3
,2
,2
0, ARRESTER
(TYP)
WATER
HAMMER
,6
,3
M27
NEW DOMESTIC WATER PIPING ISOMETRIC DIAGRAM
ISOMETRIC DIAGRAM
NEW DOMESTIC WATER PIPING
A
A
A
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P- 4P-
,8
P-
P- 1P-
,6
P-
P-
P- 5P-
A
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P- 7 P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P- 5P-
P-
P-
P-
P-
P-
P-
P-
P-
A
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P- 5 P-
P- 4P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
P-
UP
D
W
W
W
W
W
D
D
D
UP
W
BATH
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
WALKWAY
WALKWAY
WALKWAY
J.C
STAIR
STAIR
WALKWAY
DAY ROOM125
MECH RM
LAUNDRY
126-1
RM
VALVE
COMM RM
N
191107
KIM, SM
MECHANICAL
40 66 M-19
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
(1st FLOOR)
NEW SEWER AND VENT PIPING PLAN
SCALE = 1:100M19
P-7
SEE DWG
PARTIAL PLAN
FOR ENLARGED 2
D
W
W
W
W
W
D
D
D
W
MECH RM
LAUNDRY
M19
SCALE = 1:50
PIPING ENLARGED PARTIAL PLAN
LAUNDRY RM SEWER AND VENT
P-5
P-7 P-7 P-5P-5
P-5
P-1
P-1 P-1
P-1 P-1
P-7
P-7 P-4
P-4
P-8
P-4x2
P-4x2
FCO
M17
SEE DWG
FOR CONT.
UP TO 2nd FLOOR
50mm VENT PIPE RISER
RISER FROM 2nd FLOOR
100mm SEWER MAIN PIPE
P-9
P-7
100 FCO
P-5
100100
P-7
FCO
P-1P-4
P-5
P-1
P-4
FCO
50100
100 FCO
(TYP OF 6)
WASHER BOX
M17
SEE DWG
FOR CONT.
50 FD
EXIST. SEWER MAIN PIPE
CONNECT TO 150mm
EXIST. SEWER MAIN PIPE
CONNECT TO 150mm
TO 2nd FLOOR
PIPE RISERS FROM & UP
100mm SEWER & 50mm VENT
50 FCO
FCO
P-1
P-5
FCO
P-5
100 FCO
P-1
P-5
FCO
P-7
FCO
P-4x2
P-7
P-5
FCO
80 FCO
FCO
P-1100 FCO
FCO
FCO
P-1
FCO
P-7
FCO
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
M19
NEW SEWER AND VENT PIPING PLAN (1st FLOOR)
1:100
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
MAY BE ADDED IN TH FUTURE)
FOR FUTURE WORK (KITCHEN SINK
ONLY COMPLETE THE BRANCH WORK
FUTURE PLAN
P.O.C
P.O.C
AND SEWER & VENT PIPE
DRAIN, FLOOR CLEANOUT
REMAIN EXISTING FLOOR
P-4x2
MECHANICAL
41 66 M-20
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BALCONY
STAIR
STAIR
J.C
DAY ROOM
STORAGE
UP
DN
WALKWAY
WALKWAY
BALCONY
CORR
UPDN
228-1
STORAGE
N
DN
DN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
J.C
BALCONY
STAIR
WALKWAY
WALKWAY
BALCONY
STAIR
DAY ROOM
CORR
STORAGE
BEDROOM
BEDROOM
P-7
P-7P-7
P-7
P-7
P-7 P-7
P-7
P-7P-7P-7
P-7
P-1
P-5
P-7
P-4P-4
P-1
P-5
P-4P-4
P-1
P-5
P-1
P-7
P-4P-4
P-1P-1
P-5 P-5
P-5
P-1
P-4
P-8
P-4P-4P-4P-4P-4 P-4
P-1
P-5P-5
P-1P-1P-1
P-5P-5
P-1P-1
P-5
P-5
P-5
P-1
P-5
P-4P-4
P-1
P-5
P-7
P-7P-7P-7P-7
P-7 P-7 P-7P-7 P-7 P-7
P-7P-7
P-4P-4P-4
P-4 P-4P-4P-4
P-4
P-4P-4P-4
P-1P-1P-1
P-1 P-1
P-1P-1P-1
P-1 P-1 P-1
P-5 P-5
P-5P-5
P-5
P-5P-5
P-5
P-5
P-5P-5
P-8
P-7
80 VTR
50,32
DOWN TO 2nd FLOOR (TYP)
100mm SEWER PIPE RISER
FROM 2nd FLOOR (TYP)
50mm VENT PIPE RISER
50 FC0
50 FC0
FCO
FCO
50 50
50 FC050 FC0
100 VTR
50 FC050 FC0 50 FC050 FC0
100 VTR
FCO
FCO
FCO
FCO
32,80
DOWN TO 1st FLOOR (TYP)
PIPE RISERS FROM AND
50mm VENT & 100mm SEWER
50,32
50 FC0
50 FC0
FCO
50 FC050 FC050 FC0 50 FC050 FC050 FC0
FROM 1st FLOOR (TYP)
50mm VENT PIPE RISER
DOWN TO 1st FLOOR (TYP)
100mm SEWER PIPE RISER
FCO
FCO
FCO
32,80
50 FC050 FC0100 FC0 50 FC0 50 FC0
50 FC050 FC0 50 FC050 FC0100 FC0
FCO
FCO
SCALE = 1:100M20
NEW SEWER AND VENT PIPING PLAN (3rd FLOOR)
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
SCALE = 1:100M20
NEW SEWER AND VENT PIPING PLAN (2nd FLOOR)
1:100
(2nd & 3rd FLOOR)
NEW SEWER AND VENT PIPING PLAN
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
MECHANICAL
42 66 M-21
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
M21 NOT TO SCALE
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
80 VTR
50(TYP)
TEST TEE
FCO
FCO
100 FCO
FCO
FCO
FCO
FCO
40 100
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
100 VTR
FCO
FCO
FCO
FCO
FCO
FCO
100 FCO
50100
FCO
FCO
FCO
50100 FCO
100 FCO
FCO
FCO
FCO
FCO
100 FCO
50 FCO
100 FCO
FCO
FCO
FCO
FCO
FCO
10050
32100
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
50 FCO
50 FCO
32 FCO
100 VTR
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
FCO
32100
NEW SEWER AND VENT PIPING ISOMETRIC DIAGRAM
ISOMETRIC DIAGRAM
NEW SEWER AND VENT PIPING
P-8
P-4
P-1
P-8
P-5 P-7
P-1
P-1
P-5
P-7
P-5
P-7
P-1
P-4
P-4
P-7
P-1
P-5
P-1 P-4 P-4
P-1
P-5
P-7
P-5
P-7 P-4 P-4
P-1
P-1
P-7P-5P-1
P-7
P-1
P-4
P-4
P-5
P-7
P-5
P-7
P-1
P-4
P-4
P-7
P-5
P-1
P-4
P-8
P-4
P-1
P-5 P-7
P-1
P-4
P-1
P-4
P-7
P-5
P-5 P-5
P-7
P-4
P-1 P-4
P-1
P-5
P-7
P-7
P-7
P-9
P-7P-5
P-4
P-1
P-7
P-5
P-4
P-1
P-1
P-4
P-7 P-5
P-5
P-1
P-4
P-4
P-7
P-1
P-7
P-5
P-1
P-4
P-4
P-1 P-7
P-5
P-5
P-7
P-4
P-4
P-1
P-7 P-5P-1
P-7
P-1
P-4
P-4
P-5
P-7
P-
P-7
P-5
P-1
P-4
P-4
P-1 P-7
P-5
P-5 P-1
P-4
P-4
P-7
P-1
P-7P-5P-1
P-7
P-1
P-4
P-4
P-7
P-5
P-7 P-5
P-4 P-1
P-7
P-4
P-1
P-5
P-7
P-5
P-7
P-5P-7
P-5
P-5
P-7
P-5
P-7
P-5
P-5
50 32
P.O.C
P.O.C
AND SEWER & VENT PIPE
DRAIN, FLOOR CLEANOUT
REMAIN EXISTING FLOOR
FCO
P-4
P-4
50 FD
MECHANICAL
43 66 M-22
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
N
M22
INSIDE THE MECH ROOM
EQUIPMENTS, DUCTS, PIPES
REMAIN EXISTING
SHEET NO.C-2 FOR CONTINUATION
MAIN PIPE SEE CIVIL DWG.
NEW 150mm FIRE PROTECTION
CONCRETE SPLASH BLOCK
OUTLET & 300x300x100
CORROSION RESISTANT
15mm SMOOTH BORE
25 25
252525
252525
25 25
25 25
252525
252525
25 25
25 25
252525
252525
25 25
25 25
252525
25 25
25 25
252525
25 25
25 25
25 25
253240
25 25
25 25
SCALE = 1:100M22
2 ENLARGED PARTIAL PLAN
SPRINKLER
DRY TYPE SIDEWALL
SEE 5 OF SHEET M-27
ASSEMBLY FOR DETAIL
FLOOR CONTROL VALVE
BACKFLOW PREVENTER
DOUBLE CHECK
ALARM CHECK VALVE
150mm
UP TO SECOND FLOOR
150mm PIPE RISER
HOSE VALVES CONNECTION
IN-LINE TEST HEADER WITH
150x65x65mm 2-WAY, CONNECTION
FIRE DEPARTMENT
150x65x65mm
TAMPER SWITCH (TYP)
OS & Y VALVE WITH
(TYPICAL)
AUTOMATIC SPRINKLER
UPRIGHT TYPE
AUTOMATIC SPRINKLER (TYP.)
CONCEALED PENDENT TYPE
50 65 65 80 80 100 100
100 100 40
25 25
LOCKABLE GLOBE VALVE
DRAIN PIPE WITH
25 INSPECTION & TEST
FROM SECOND FLOOR
25mm TEST PIPE RISER
D
W
W
W
W
W
D
D
D
W
LAUNDRY
126-1
RM
VALVE
FROM SECOND FLOOR
25mm DRAIN PIPE RISER
HEAD CABINET
SPARE SPRINKLER
SEE DWG
FOR ENLARGED PLAN
M22
SCALE = 1:50
NEW FIRE PROTECTION PIPING PLAN (1st FLOOR)
AS SHOWN
(1st FLOOR) & ENLARGED PARTIAL PLAN
NEW FIRE PROTECTION PIPING PLAN
SCALE: 1:100
0 2000 4000
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
UP
D
W
W
W
W
W
D
D
D
UP
W
BATH
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
WALKWAY
WALKWAY
WALKWAY
J.C
STAIR
STAIR
WALKWAY
DAY ROOM
MECH RM
LAUNDRY
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
SVC. AREA
SVC. AREA
126-1
RM
VALVE
COMM RM
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
MAX. SPRINKLER SPACING
DURATION OF SUPPLY
SPRINKLER TEMP. RATING
DESIGN DENSITY
DESIGN AREA
SPRINKLER HEADS
OCCUPANCY CLASSIFICATION
"K" FACTOR
4.6M (15FT)
60 MINUTES
8.0 (115)
4.6M (15FT)
60 MINUTES
140 SM (1500 SF)
5.6 (80)
APPLICATION AREA
4.0 LPM/SM (0.1 GPM/SF) 8.0 LPM/SM (0.2 GPM/SF)
57°C-77°C (135°F-171°F) 57°C-77°C (135°F-171°F)
LIGHT HAZARD ORDINARY HAZARD (GROUP I)
MAX. COVERAGE PER SPRINKLER 12.1 SM (130 SF)18.6 SM (200 SF)
HOSE ALLOWANCE 950 LPM (250 GPM)
LAUNDRY/STORAGE
MECH RM/VALVE RM/COMM RM/
950 LPM (250 GPM)
230 SM (2500 SF)
LISTED QUICK RESPONSE, CONCEALED LISTED QUICK RESPONSE, CONCEALED
DESIGN CONDITIONS
LIVING/BEDROOM AREAS
DAY ROOM &
191107
KIM, SM
MECHANICAL
44 66 M-23
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
SCALE = 1:100M23
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
N
FROM THIRD FLOOR
25mm TEST PIPE RISER
DOWN TO FIRST FLOOR
25mm TEST PIPE RISER
25 25
252525
252525
25 25
25 25
252525
252525
25 25
25 25
252525
252525
25 25
25 25
252525
25 25
25 25
252525
25 25
25 25
25 25
253240
25 25
25 25
SPRINKLER
DRY TYPE SIDEWALL
(TYPICAL)
AUTOMATIC SPRINKLER
UPRIGHT TYPE
50 65 65 80 100
80 100 100
FROM THIRD FLOOR
25mm DRAIN PIPE RISER
FROM FIRST FLOOR
150mm PIPE RISER
SEE 5 OF SHEET M-27
ASSEMBLY FOR DETAIL
FLOOR CONTROL VALVE
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BALCONY
STAIR
STAIR
J.C
DAY ROOM
STORAGE
SVC. AREA
CLOSET
WALK-IN
CLOSET
WALK-IN
SVC. AREA CLOSET
WALK-IN
CLOSET
WALK-IN
UP
DN
WALKWAY
WALKWAY
BALCONY
CORR
UPDN
228-1
STORAGE
AUTOMATIC SPRINKLER (TYP.)
CONCEALED PENDENT TYPE
NEW FIRE PROTECTION PIPING PLAN (2nd FLOOR)
1:100
(2nd FLOOR)
NEW FIRE PROTECTION PIPING PLAN
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
MECHANICAL
45 66
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
SCALE = 1:100M24
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
N
DOWN TO SECOND FLOOR
25mm TEST PIPE RISER
25 25
252525
252525
25 25
25 25
252525
252525
25 25
25 25
252525
252525
25 25
25 25
252525
25 25
25 25
252525
25 25
25 25
25 25
253240
25 25
25 25
SPRINKLER
DRY TYPE SIDEWALL
(TYPICAL)
AUTOMATIC SPRINKLER
UPRIGHT TYPE
AUTOMATIC SPRINKLER (TYP.)
CONCEALED PENDENT TYPE
50 65 65 80 100
80 100 100
FROM SECOND FLOOR
100mm PIPE RISER
DOWN TO SECOND FLOOR
25mm DRAIN PIPE RISER
SEE 5 OF SHEET M-27
ASSEMBLY FOR DETAIL
FLOOR CONTROL VALVE
NEW FIRE PROTECTION PIPING PLAN (3rd FLOOR)
(3rd FLOOR)
NEW FIRE PROTECTION PIPING PLAN
1:100 M-24
3150 49784
57911829 5690 5690 5690 5690 5690 5690 8026
C D E F G H J KA-6 B LK-4A
DN
DN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
J.C
BALCONY
STAIR
WALKWAY
WALKWAY
STAIR
DAY ROOM
CORR
BEDROOM
BEDROOM
SVC. AREA
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
SVC. AREA
BALCONY
STORAGE
MECHANICAL
46 66 M-25
NTS
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
CEILING DIFFUSER
REGISTER OR GRILLE
TYPE A
NOTES:
TYPE B
UP TO 300
325 - 650
650 - 1200
(mm)
DUCT DIA.
1250 - 1500
1550 - 1825
1850 - 2450
2475 UP
(MIN.)
DUCT GAGE
0.75
1.50
(MAX.)(m)
REINF. SPACING
TRANSVERSE JOINT
T-3.5.6.10.12.13.14.16.17.18.19.22 & L-1.2.3.4
T-3.6.10.12.13.14.17.18.19.22 & L-1.2.3.4
T-3.6.13.14.17.18.19.22 & L-1.2.3.4
DUCT CONSTRUCTION SCHEDULE
STANDING"S"SLIP
(T-12)(T-10)
STANDING"S"SLIP
AIR FLOW AIR FLOW
HEMMED"S"SLIP
(T-6)
AIR FLOWAIR FLOW
PLAIN "S" SLIP
(T-3)
DRIVE SLIP
(T-5)
STANDING"S"SLIP
BAR REINFORCED
AIR FLOW
(T-13)
(T-14)
STANDING"S"SLIP
ANGLE REINFORCED
AIR FLOW
STANDING SEAM
REINFORCED
ANGLE
(T-16) (T-17)
POCKET LOCK
AIR FLOW
POCKET LOCK
BAR REINFORCED
(T-18)
GROOVED SEAM
(L-3)
SNAP LOCK
BUTTON PUNCH
(L-2)
DETAIL
SEE
LOCK
PITTSBURGH
(L-1)
(T-22)
(CAULK OR GASKET)
COMPANION ANGLES
GASKET
WELD
RIVET OR
POCKET LOCK
ANGLE REINFORCED
(T-19)
AIR FLOW
MALE PIECE-SNAP LOCK
50mm
"BUTTONS"
BETWEEN
SPACING
APPROX. 50mm
STANDING SEAM
(L-4) DETAIL
GENERAL NOTES
SPLITTER DAMPER
UNIVERSAL JOINT
LOCK NUT BRANCH DUCT
o
F
LOW
AI
R
MAX.30°
150 W x 150 H
DUCT ACCESS HOLE
REGULATING BAR 7
MAIN DUCT
TRANSITION
VOLUME DAMPER
EXTENDED PIN
DUCT
BRANCH
PIANO HINGE
(MIN OF 100)
CLINCH COLLAR
WHICH INSTALLED.
HEAVIER THAN DUCT IN
SHALL BE TWO GAUGES
DAMPER AND SPLITTER
BRANCH TAKE - OFF
NOTE:
ARCH DWG
DETAIL SEE
CEILING, FOR
BE PLACED IN THE NECK WITH ITS BLADES SET PARALLEL TO LONGER ROOM SIDE.
WHEN ROOM SIDE DIMENSIONS ARE • TO 1, AN EQUALIZING DEFLECTOR SHOULD
FOR THE APPROX. SQUARE ROOM EQUALIZING DEFLECTOR IS NOT REQUIRED.
AND DEFLECTOR
COMBINATION DAMPER
SHAFT
FLEXIBLE
AIR
DEFLECTOR
EQUALIZING
DUCT RING
DAMPER STOP
COUPLING
EXTENSION
END OF DUCT
(150 MIN)
AIR CUSHION
INSULATION
MAX 45°
PIN
COTTER
NOTE:
NO VOLUME CONTROL.
GRILLE. GRILLE HAS
VOLUME CONTROL AT
REGISTER CONTAINS
END OF DUCT
AIR CUSHION
INSULATION
AIR FLOW
AIR DUCT
CEILING
NOTE:
150 (MIN)
HEIGHT-6mm
HEIGHT W/
EXTRACTOR
80mm
AIRW -6mm
W x
M A
X
W
THE NEED FOR A CEILING ACCESS PANEL.
MOUNTED OPERATOR KNOB ELIMINATING
TYPE-B IS ROTARY OPERATED BY A CEILING
MOVABLE KEY OPERATOR.
FACE OF REGISTER OR GRILLE WITH A
MECHANISM ACCESSIBLE THROUGH THE
TYPE-A IS OPERATED WITH A WORM DRIVE
W
2 AIR EXTRACTOR
STEEL ANGLE BAR
32x32x3 THK
NUTS (TYP)
10mm BOLTS &
NUTS (TYP)
10mm BOLTS &
STEEL FRAME
STRUCTURAL
ATTACHED TO
ANGLE BAR TO BE
32x32x3 THK STEEL
STEEL FRAME
STRUCTURAL
ATTACHED TO
ANGLE BAR TO BE
32x32x3 THK STEEL
STEEL ANGLE BAR
32x32x3 THK STEEL ANGLE BAR
32x32x3 THK
AIR DUCTAIR DUCT
STEEL ANGLE BAR
32x32x3 THK
STEEL ANGLE BAR
32x32x3 THK
STEEL ANGLE BAR
32x32x3 THK
(TYP)
3mm FASTENER
(TYP)
3mm FASTENER
1 VERTICAL DUCT SUPPORT
DETAILS - 1
SPECIFICATIONS.
7. ALL PIPE PENETRATIONS OF FIRE RATED WALL MUST BE INSTALLED IN ACCORDANCE W/MANUFACTURER'S LISTED INSTRUCTIONS AND THE
VENTILATION BY ACGIH, ASHRAE HANDBOOKS, AND NFPA 90A OR 90B.
6. OTHER DUCT WORK DETAILS NOT SHOWN SHALL CONFORM TO LOW VELOCITY DUCT CONSTRUCTION STANDARDS BY SMACNA, INDUSTRIAL
INSTALLED AT LEAST 150mm BELOW THE CEILING.
5. SPONGE-RUBBER GASKETS SHALL BE PROVIDED BETWEEN DIFFUSERS OR REGISTERS AND WALL OR CEILING, AND WALL REGISTERS SHALL BE
300mm BEYOND THE OPENING OF THE REGISTER OR GRILLE OR DIFFUSER.
4. WHEN A SUPPLY AIR REGISTER OR GRILLE OR DIFFUSER IS LOCATED AT THE END OF THE DUCT, THE DUCT SHALL BE EXTENDED 150mm TO
3. PROVIDE CLASS C SEAL AT ALL DUCTWORK
1520mm ABOVE FINISH FLOOR.
2. TURNING VANES SHALL BE INSTALLED IN ALL SQUARE ELBOWS. UNLESS OTHERWISE SPECIFIED, ROOM THERMOSTAT SHALL BE INSTALLED
1. WHERE DUCTS ARE INSTALLED ABOVE CEILING,ACCESS PANELS SHALL BE PROVIDED IN CEILING FOR DUCT ACCESS DOORS, DAMPERS, ETC.
L2 L1 L2L1
100 FT
PIPE
SIZE
10"
L1
1'4"
1'5"
1'9"
2'4"
L2
3" 3'6"
APPROXIMATE DISTANCE BETWEEN ADDITIONAL PIPE GUIDES
@50 PSI
23'
28'
32'
35'
38'
21'
2'11"
4"
5"
6"
8"
1'
1"
1-1/4"
1-1/2"
2"
2-1/2"
@100 PSI
17'
20'
23'
28'
28'
15'
@150 PSI
13'
17'
18'
22'
23'
12'
@300 PSI
12'
13'
15'
20'
17'
10'
4" 4'8" 52' 38' 31' 22'1'4"
54 PIPE EXPANSION JOINT
BELLOWS TYPE
(TYPICAL)
EXPANSION GUIDE
PIPE
(TYPICAL)
PIPE ANCHOR
2. CONCENTRIC PIPE GUIDE SPACING
HEATING HOT WATER @180°F : 2.051"/100'
DOMESTIC HOT WATER @120°F : 1.366"/100'
1. COPPER PIPE THERMAL EXPANSION
NOTE ;
* DATA PER EXPANSION JOINT MANUFACTURERS ASSOCIATION
WATER SERVICE
UNION
G.L
REDUCING TEE
WATERPROOF MASTIC
REDUCING TEE
20 HOSE BIBB
13 FEMALE ADAPTER
WATER METER
STRAINER
PRESSURE GAUGE
MALE ADAPTER
CHECK VALVE
GATE VALVE
MALE ADAPTER
FFL
PIPE SLEEVE THRU FOOTING.
PIPE SLEEVE THRU FLOOR.
MECHANICAL
47 66 M-26
NTS
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
DETAILS - 2
1 P I P E H A N G E R 2 HOT WATER PIPING FOR FINNED TUBE RADIATOR
3 FIRE DAMPER 6 DUCT THRU FLOOR
PIPE SIZE
1/2
3/4
3/8
A
3/8
3/8
3/8
3/8
3/8
1/2
1/2
1/4
BOLT SIZE
1/4
1/4
1/4
1/4
1/4
3/8
3/8
TOP STOCK
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
1/8 x 1
BOTTOM STOCK
(UNIT : INCH)
‰ x 1‚
‰ x 1‚ ‰ x 1‚
‰ x 1‚
2•
1•
1‚
PIPE SIZE A STOCK SIZE
5/8
5/8
3/4
7/8
7/8
(UNIT : INCH)
‚ x 1•
… x 1ƒ
… x 2
… x 2•
• x 2•
TOP STOCK
BOLT
INSULATION
PIPE
BOTTOM STOCK
SHIELD
PROTECTION
INSERT
DENSITY
HIGH
12"
A
PIPE
STOCK
INSULATION
SHIELD
PROTECTION
C.I. ROLLER
SADDLE
PROTECTION
12"
REDUCING TEE (UP FEED PIPING ONLY)
ECCENTRIC REDUCER
FINNED TUBE RADIATOR
AUTO AIR VENT (UP FEED PIPING ONLY)
RADIATOR COVER
ACCESS DOOR
NON-ELECTRIC THERMOSTATIC RADIATOR VALVE (NETRV)
BALANCING COCK W/ FLOW MEASURING DEVICE
3 4
2 7
PITCH UP
F.L. FLOOR PLATE
RETURN MAIN
SUPPLY MAIN
RETURN MAIN
SUPPLY MAIN
3 4
7 1 57 62
PITCH UP
EXPANSION
ON TOP & SIDES FOR
PROVIDE CLEARANCE
ON SIDES
BOTTOM & DRIVE SLIP
WITH "S" SLIP ON TOP &
FASTEN DUCT TO SLEEVE
RETAINING ANGLE (TYP)
SIDES OF WALL
ALL AROUND ON BOTH
APPLY SEALANT TO JOINT
FIRE RATED WALL
IS ACCEPTABLE
EXPANSION IN WIDTH
REDUCE AREA OF DUCT
FIRE DAMPER DOES NOT
EXPAND DUCT SO THAT
DUCTWORK
ACCESS DOOR
FIRE DAMPER
WITH UL RATING & STAMP
TYPE FIRE DAMPER
VERTICAL GUILLOTINE
HORIZONTAL INSTALLATION (FLOOR)
VERTICAL INSTALLATION (WALL)
WIDTH IS ACCEPTABLE
AREA OF DUCT EXPANSION IN
DAMPER DOES NOT REDUCE
EXTEND DUCT SO THAT FIRE
RETAINING ANGLE (TYP)
SIDES OF WALL
ALL AROUND ON BOTH
APPLY SEALANT TO JOINT
ACCESS DOOR
FIRE DAMPER
DUCTWORK
SLEEVE
ON SIDES
& BOTTOM & DRIVE SLIP
WITH "S" SLIP ON TOP
FASTEN DUCT TO SLEEVE
UL RATING & STAMP
FIRE DAMPER WITH
MANUFACTURER'S LISTED DETAIL FOR INSTALLATION SHALL BE FOLLOWED.
THIS DETAIL IS FOR INFORMATION ONLY. THE FIRE DAMPER
NOTE :
SLEEVE SEALANT
FIRE RATED
APPROVED
FILL WITH AN
(TYPICAL)
38x38x355 GAUGE
MINIMUM 38x38x350
ANGLE SHALL BE A
GALVANIZED STEEL
25mm MIN. GAP
CONNECTION
AIR DUCT
BLADE LOCK
ENDS (TYP)
SEALED AT BOTH
VAPOR BARRIER
INSULATION WITH
SPRING
NEGATOR CLOSURE
STAINLESS STEEL
CONCRETE SLAB
FIRE DAMPER
LINING
ACOUSTICAL
6mm MIN. CLEARANCE
NOTE:
2. VERIFY INSTALLATION WITH VENDOR
AND WITH ACCESS FROM ABOVE.
1. DAMPER TO BE INSTALLED WITH BLADE POINTS FACING DOWNWARD,
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
M-339 DUCT HANGER DETAIL 23 00 00
23 07 00M-320
23 00 00M-338
23 00 00M-324
23 00 00M-327
23 00 00M-328
DUCT INSULATION
DUCT ACCESS DOOR DETAIL
DUCT TURNING VANES & RUNNERS DETAILS
PROPELLER & CENTRIFUGAL EXHAUST FAN
TYPICAL POWER TYPE ROOF VENTILATION
23 07 00M-902
22 00 00M-305
22 00 00M-308
22 00 00M-412
M-413
22 00 00M-416
PIPE INSULATION DETAIL
EXPANSION LOOP
PIPE ANCHOR
22 00 00M-415
M-204
M-206
M-217
M-218
M-219
DRAINS
FLOOR CLEANOUT 22 00 00
WASHING DRAIN STAND PIPE
SEISMIC DETAILS FOR SWAY BRACING
TEST PIPE CONNECTION DETAIL 21 13 13.00 10 21 13 13.00 10
21 13 13.00 10
21 13 13.00 10
STANDARD INSTALLATION SPRINKLERS
TYP. SPRINKLER INSTALL.-UPRIGHT TYPE
4-WAY SEISMIC BRACING
DWG. NO. TITLE SPEC. NO.
21 13 13.00 10
LIST OF OMA STANDARD DETAILS TO REFERENCE
21 13 13.00 10
22 00 00M-316 PIPE SLEEVE-THRU FLOOR
22 00 00M-317 PIPE SLEEVE-THRU INTERIOR WALL
23 64 26M-301 CHEMICAL FEEDER
23 00 00M-330 FLEXIBLE CONNECTION & ANGLE FLANGE CONNECTION
E
90°
12"
A
C
B
D 10"
5"
MOVEMENT
O PIPE
EQUAL
ASSEMBLY
SPIDER
ASSEMBLY
CYLINDER
SIZE
PIPE
INSUL
MAX.
125 150
A B C D E
(UNIT : mm)
1 PIPE GUIDE
PIPE
CAST IRON
Y-BRANCH
MEMBRANE
WATERPROOF
PIPE CHASE
PIPE END PLUG
WHEN NOT THRU RUN
PLUG Y-BRANCH
3mm BEND
PACKING
TARRED JUTE
4 WALL CLEANOUT
CLEANOUT TEE
PIPE COUPLING
SCREW TYPE
CAST BRASS HEAD
COUNTERSUNK PLUG,
SCREW BOLT
STAINLESS STEEL
SECURED ACCESS COVER
STAINLESS STEEL
NOTE
SPARE SPRINKLER HEAD CABINET
.4 mm
.4 mm
2.
0mm
82.6mm
3.
8mm
(6 S
PRI
NKLER
CABI
NET)
CABI
NET)21
9.
1mm
(1
SPRI
NKLER
6.
4mm
MOUNTI
NG
HOLES
0.
4mm
ON
CENTER
TWO SHELVES FOR 12 SPRINKLER CABINET
ONE SHELF FOR 6 SPRINKLER CABINET
TYP. SPRINKLER INSTALL.-SIDEWALL TYPE & FLUSHING CONNECTION
M-205 21 13 13.00 10 FIRE DEPARTMENT CONNECTION WITH PLUG AND CHAIN
191107
KIM, SM
MECHANICAL
48 66 M-27
NTS
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
DETAILS - 3
REFERENCE :
TO DRAIN
TO SYSTEM
FLOOR CONTROL VALVE DETAIL
NOTE:
MACHINE
WASHING
WASHER BOX DETAIL
FRONT VIEW SIDE VIEW
(TYP)
•" UNION
2" STAND PIPE
SERVICE BOX
HOSE BIBB
•" CW & •" HW
2"
1•" VENT
PIPE
2" STAND
SWITCH AND MIN 6" (150mm) BETWEEN WATER FLOW SWITCH AND FEED MAIN TEE.
1. PROVIDE MIN 24" (600mm) DISTANCE BETWEEN OS & Y VALVE AND WATER FLOW
ORIFICE IN THE SYSTEM
SMALLEST SPRINKLER
FLOW EQUIVALENT TO THE
RESISTANT ORIFICE GIVING
UNION WITH CORROSION-
DRAIN VALVE
SECTIONAL
WATERFLOW SWITCH
PRESSURE GAUGE
W/ TAMPER SWITCH
OS & Y VALVE
FEED MAIN
RISER
SIGHT GLASS
TEST VALVE
UFC 3-600-01, FIG. 4-1.
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
MAIN PIPE RISER CONNECTION
PIPE SLEEVE-THRU INTERIOR WALLPIPE SLEEVE-THRU FLOOR WITH WATERPROOFING
PIPE SLEEVE-THRU FOOTING1 WET PIPE SYSTEM SPRINKLER ALARM VALVE DETAIL
PIPEEXTERIOR CL
P I
P E
C
PIPE CL
G.L
0.0176
S E
N O
T E
2. PROVIDE LONG SWEEP ELBOWS AT MAIN PIPE RISER.
NOTES :
FOR FIRE PROTECTION APPLICATION.
1. FLEXIBLE COUPLING SHALL BE UL LISTED APPROVED
THRUST BLOCK
CONCRETE
SPIGOT PIPE
BELL AND
DUCTILE IRON
STEEL PIPE
WATERPROOF MASTIC
(TYPICAL, SEE NOTE)
FLEXIBLE COUPLING
FFL
AND SPIGOT PIECE
DUCTILE IRON FLANGE
SEE DETAIL ON THIS SHEET
PIPE SLEEVE THRU FLOOR
6mm THK FLAT STEEL BAR
15mm ANCHOR BOLT (TYP)
NFPA 24 AND SHALL BE BITUMASTIC COATED.
TIE ROD SIZE SHALL BE IN ACCORDANCE WITH
NOTE :
oTHAN 20mm
RODS NOT LESS
NOTES ON UL LISTED FLEXIBLE COUPLINGS :
VERTICAL PIPE.
ANY INTERMEDIATE POINTS OF SUPPORT FOR A RISER OR OTHER
(6) WITHIN 24 INCH (610 MM) ABOVE AND 24 INCH ( 610 MM) BELOW
MORE THAN ONE SPRINKLER, REGARDLESS OF PIPE SIZE.
15 FT (4.6 M) IN LENGTH TO PORTIONS OF SYSTEMS SUPPLYING
(5) WITHIN 24INCH (610 MM) OF THE TOP OF DROPS EXCEEDING
(4) WITHIN 24INCH (610 MM) OF BUILDING EXPANSION JOINTS.
WITH 9.3.4.
OF THE WALL SURFACE, UNLESS CLEARANCE IS PROVIDED IN ACCORDANCE
(3) ON BOTH SIDES OF CONCRETE OR MASONRY WALLS WITHIN 1FT(305 MM)
INCORPORATES A RISER.
(B) ON THE VERTICAL PORTION OF THE TIE-IN WHERE THE TIE-IN
TIE-IN WHERE THE TIE-IN IS HORIZONTAL.
(A) ON THE HORIZONTAL PORTION WITHIN 24INCH (610 MM) OF THE
WITH ONE OF THE FOLLOWING:
THAT FLOOR, A FLEXIBLE COUPLING SHALL BE PROVIDED IN ACCORDANCE
BELOW THE FLOOR IS ABOVE THE TIE-IN MAIN TO THE MAIN SUPPLYING
THE FLOOR IN MULTISTORY BUILDINGS. WHEN THE FLEXIBLE COUPLING
(2) WITHIN 12INCH (305 MM) ABOVE AND WITHIN 24INCH (610MM) BELOW
COUPLING IS ADEQUATE.
(B) IN RISERS 3FT TO 7FT(0.9M TO 2.1M) IN LENGTH, ONE FLEXIBLE
ARE PERMITTED TO BE OMITTED.
(A) IN RISERS LESS THAN 3FT(0.9M) IN LENGTH, FLEXIBLE COUPLINGS
UNLESS THE FOLLOWING PROVISIONS ARE MET:
(1) WITHIN 24 INCH(610 MM) OF THE TOP AND BOTTOM OF ALL RISERS,
INSTALLED AS FOLLOWS:
BRACING AS REQUIRED IN 9.3.5.3.8. THE FLEXIBLE COUPLINGS SHALL BE
REQUIRED BY THIS SECTION SHALL BE PROVIDED WITH ADDITIONAL SWAY
PER NFPA 13-2013.9.3.2.3 SYSTEM HAVING MORE FLEXIBLE COUPLINGS THAN
FLANGE
WATERPROOFING CLAMPING
RUBBER OR PLASTIC)
(CLOSED CELL FLEXIBLE FOAM
BACK UP MATERIAL ALL AROUND
(SEE SPECS 07 92 00)
(ASTM 920) ALL AROUND
EXTERIOR ELASTOMERIC SEALANT
WATERPROOFING MEMBRANE
PIPE SLEEVE ALL AROUND
BACK UP MATERIAL ALL AROUND
INTERIOR
ANCHOR
CONCRETE OR MASONRY WALL
(ASTM 920)ALL AROUND
INTERIOR ELASTOMERIC SEALANT
GENERAL NOTES :
COPPER
METER OR 450 GMS
FLASHING 20 KG/SQ.
FIN FLR
RUBBER OR PLASTIC)
FLEXIBLE FOAM
AROUND (CLOSED CELL
BACK UP MATERIAL ALL
(SEE NOTE 1)
PIPE SLEEVE ALL AROUND
(SEE SPECS 07 92 00)
(ASTM 920)ALL AROUND
ELASTOMERIC SEALANT
WATERPROOFING
RUBBER OR PLASTIC)
FLEXIBLE FOAM
AROUND (CLOSED CELL
BACK UP MATERIAL ALL
(SEE SPECS 07 92 00)
(ASTM 920)ALL AROUND
ELASTOMERIC SEALANT
ANCHOR (TYP)
CEILINGMASONRY WALL
CONCRETE OR
NOTE :
LINE
FROST
BELOW
SEE DETAIL ON THIS SHEET
PIPE SLEEVE-THRU FOOTING
CHECK VALVE
PTO FIRE ALARM
PRESSURE SWITCH
WATER FLOW ALARM
WATER SUPPLY
MAIN DRAIN
MAIN SERVICE
MAIN PIPE FROM
FIRE PROTECTION
CONNECTION
FIRE DEPARTMENT
CONNECTION
WITH HOSE VALVES
INLINE TEST HEADER
CAP PLATE (TYP)
125x125x10 THK
PIPE (TYP)
50mm DIA STEEL
VALVE ASSEMBLY
DOUBLE CHECK
TAMPER SWITCH (TYP)
OS & Y VALVE w/
SADDLE (TYP)
U-BOLT (TYP)
BOLTS (TYP)
PLATE w/ ANCHOR
200x20x10 THK BASE
SPLASH BLOCK
CONCRETE
SEE DETAIL ON THIS SHEET
MAIN PIPE RISER CONNECTION
CHAMBER
RETARDING
DRAIN PIPE
MAIN
DRIP
BALL
TO SYSTEM
w/ TAMPER SWITCH
ALARM SHUT-OFF VALVE
191107
KIM, SM
MECHANICAL
49 66 M-28
NTS
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
DETAILS - 4
(TYPICAL, SEE NOTE)
FLEXIBLE COUPLING
GAUGE (TYP.)
WET PIPE PRESSURE
ALARM CHECK VALVE (TYP.)
WET PIPE
PRESSURE SWITCH (TYP.)
TAMPER SW.) (TYP.)
(GLOBE VALVE W/
ALARM TEST VALVE
SWITCH (TYP.)
Y VALVE w/ TAMPER
WET PIPE OS &
BALL VALVE (TYP.)
(SEE NOTE 1)
ALL AROUND
PIPE SLEEVE
SIZES 4 IN. AND LARGER.
NOMINAL DIAMETER OF THE PIPE SHALL BE ACCEPTABLE FOR PIPE
BY A PIPE SLEEVE OF NOMINAL DIAMETER 4 IN. LARGER THAN THE
SIZES 1 IN. THROUGH 31/2 IN., AND THE CLEARANCE PROVIDED
NOMINAL DIAMETER OF THE PIPE SHALL BE ACCEPTABLE FOR PIPE
PIPE SLEEVE, A NOMINAL DIAMETER 2 IN. LARGER THAN THE
1. PER NFPA 13-2013.9.3.4.3 WHERE CLEARANCE IS PROVIDED BY A
AND LARGER.
ACCEPTABLE FOR PIPE SIZES 100mm
DIAMETER OF THE PIPE SHALL BE
100mm LARGER THAN THE NOMINAL
PIPE SLEEVE OF NOMINAL DIAMETER
AND THE CLEARANCE PROVIDED BY A
FOR PIPE SIZES 25mm THROUGH 90mm, OF THE PIPE SHALL BE ACCEPTABLE
LARGER THAN THE NOMINAL DIAMETER
SLEEVE, A NOMINAL DIAMETER 50mm
CLEARANCE IS PROVIDED BY A PIPE
2. PER NFPA 13-2013.9.3.4.3 WHERE
SECTION 07 92 00.00 31.
CONFORMANCE WITH SPECIFICATIONS
1. PROVIDE ELASTOMERIC SEALANTS IN
STEEL PIPE
100mm DIA
DETAIL ON SHEET M-29
4-WAY BRACING (TYP) SEE
2 3
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
NOTE :
PIPE TIGHT TO STRUCTURE
CLIP-ON WRAPAROUND U-HOOK DEVICES
MAXIMUM DISTANCE BETWEE HANGERS (m-mm)
SEISMIC BRACE DETAILS
HANGERS FOR END-OF-LINE (OR ARMOVER) PENDENT SPRINKLER
SPRINKLER PIPE
OR 65x65x6mm ANGLE
40x40x6mm ANGLE
NUT (TYP)
10mm BOLT AND
STEEL STRAP
50mm WIDEx6mm THK
° 4
SPRINKLER PIPE
OR 65x65x6mm ANGLE
40x40x6mm ANGLE
NUT (TYP)
10mm BOLT AND
BOTTOM CHORD
STRUCTURAL MEMBER
STEEL ANGLE WELD TO
2400mm (65x65x6mm ANGLE)
1200mm (40x40x6mm ANGLE)
MAXIMUM LENGTH :
SPRINKLER PIPE
NUT (TYP)
20mm BOLT AND
STEEL STRAP
50mm WIDEx6mm THK
WEB MEMBERS
SHORT STRAP U-HOOK
U-HOOK
WRAP-AROUND
TO PIPE
RING-ROD TIGHT
ADJUSTABLE SWIVEL
SUPPRESSOR
RING WITH SURGE
ADJUSTABLE SWIVELCLEVIS HANGER
(mm)
PIPE SIZE
D(mm)
DIMENSION
3.175
3.175
3.175
6.350
6.350
SIZE (mm)
NOMINAL PIPE
STEEL PIPE
THREADED LIGHTWALL
COPPER TUBE
CPVC
POLYBUTYLENE (IPS)
POLYBUTYLENE (CTS)
DUCTILE IRON PIPE
20 25 32 40 50 65 80 80100 125 150 200
N/A
N/A
N/A
N/A N/A N/A N/A N/A N/A N/A N/A
N/AN/AN/AN/AN/A
N/AN/AN/AN/AN/AN/AN/A
N/AN/AN/AN/AN/AN/AN/A
N/AN/AN/AN/AN/A
1.15
3.65
3.65
2.44 2.44
1.83
3.65 4.60 4.60 4.60 4.60 4.60 4.60 4.60 4.60 4.60
3.65 3.65 3.65 3.65 3.65
4.60 4.60 4.60 4.60 4.603.65 3.65 3.653.28 3.28
4.60 4.60 4.60 4.60
1.68 1.98 2.14 2.44 2.75 3.00
0.89 1.00 1.20
1.40
1.35
1.52
1.65
1.80
THREADED LIGHTWALL
STEEL PIPE EXCEPT
FOR SI UNITS:
1 FT. = 0.3048 m
1 IN. = 25.4 mm
NOTES:
CTS - COPPER TUBE SIZE
IPS - IRON PIPE SIZE
NOTE :
FOR HANGING, BRACING AND RESTRAINT OF SYSTEM PIPING SEE NFPA 13.
REFERENCE: NFPA 13-2007.
I
M E
N S I
O N
PYT
.54
FOR STIFFENING
PIPE OVER ROD Y
T P.
O R
L
P I P E
5°
OR L
PIPE
OR L
PIPE
CAST INSERTS
TYP.
N
T
V
E R m m
U S
H A
N G
E R
I
FNOT OVER 600mm
USE HANGER IF
CAST INSERT
ANGLE OR EQUAL
CONNECTION
2-BOLTS IN EACH
TRUSS
VERTICAL MEMBER
CLIP L
STEEL STRAP
50mmW x 6mmT
THE SHOP DRAWINGS FOR REVIEW AND APPROVAL.
SELECTION PER NFPA 13 AND TO BE NOTED IN
INSTALLATION ANGLES AND FASTENER
MATERIALS, MAXIMUM LENGTH, SPACING,
THE ADEQUACY OF SWAY BRACES AND PIPE SUPPORT
AND PIPE SUPPORT CALCULATION TO ESTABLISH
2. THE CONTRACTOR SHALL PROVIDE SWAY BRACING
ADDITIONAL REQUIREMENTS.
1. CONTRACTOR TO REFER TO NFPA 13 - 2013 FOR
191107
KIM, SM
MECHANICAL
50 66 M-29
NTS
K16, AIRFIELD
REPAIR BUILDING S-156
FY18
DETAILS - 5
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
ENGINEERING DIVISON, DPW, USAG-YONGSAN
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
GENERAL NOTES
2.MOUNTING HEIGHTS ABOVE FLOOR SHALL BE AS FOLLOW UNLESS OTHERWISE
NOTED ON THE DRAWING.
LIGHTING FIXTURE SEE LIGHTING FIXTURE SCHEDULE
PANELBOARD SEE SPECIFICATION
SAFETY SWITCH 1524mm TO CENTER OF THE ENCL
RECEPTACLE,TELEPHONE OUTLET 305mm TO CENTER OF THE ENCL
MOTOR CONTROLLER 1524mm TO CENTER OF THE ENCL
1676mm TO CENTER OF THE ENCL
2286mm TO CENTER OF BELL
3.
4.
6.THE SOIL RESISTANCE TO GROUND FOR THE ELECTRICAL AND COMMMUNICATION
SYSTEMS SHALL BE 25 OHMS OR LESS. THE SOIL RESISTANCE TEST SHALL BE
7.
COORDINATED WITH THE CENTRAL FIRE DEPARTMENT SO THAT
THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING
ON CEILINGDETECTOR
1372mm TO CENTER OF STATIONMANUAL PULL STATION
5.
CONDUCTED BY THE CONTRACTOR TO OBTAIN THE REQUIRED SOIL RESISTANCE.
INDICATEDS 2 #12AWG IN 16C
INDICATEDS 3 #12AWG IN 16C
INDICATEDS 4 #12AWG IN 16C
A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS;
1219mm TO CENTER OF THE ENCLWALL SWTICH
CONDUIT UNLESS OTHERWISE INDICATED.
ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG. "TW" IN 16C
AND LOCATION OF THE F/A ANTENNA WITH THE CENTRAL FIRE DEPARTMENT
THE CONTRACTOR SHALL SUBMIT THE SHOP DRAWING FOR THE MOUNTING
TO TRANSMIT THE ALARM RADIO SIGNAL WAVE WITHOUT ANY OBSTRUCTION.
DETAIL OF THE F/A ANTENNA, AND COORDINATE THE MOUNTING HEIGHT
F/A EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.
THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING
1.
SCOPE OF WORK
F/A & MNS EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.
THE MANUFACTURER AND MODEL OF NEW F/A& MNS EQUIPMENT SHALL BE
F/A &MNS CONTROL
COMBO. SPEAKER & STROBE
8.
SINGLE POLE TOGGLE SWITCH, 15A-125V
L E G E N D
FLEXIBLE CONDUIT W/CONNECTORS
LIGHTING
WIRING
POWER
INTERIOR
S
SYMBOL DESCRIPTION
DESCRIPTION
DESCRIPTION
T
J
THERMOSTAT (UNDER MECH. ITEM)
JUNCTION BOX
SYMBOL
SYMBOL
SAFETY SWITCH
C CONTROL CIRCUIT
AND GOVERNMENT INSTALLED
GOVERNMENT FURNISHED
GFGI
WEATHERPROOFWP
LA LIGHTNING ARRESTER
EXPLOSIONPROOFEP
DISTRIBUTIONDIST
GROUND FAULT PROTECTIONGFP
A AMPERE
AC ALTERNATING CURRENT
AF/AT AMPERE FRAME/AMPERE TRIP
AWG AMERICAN WIRE GAUGE
BC BARE COPPER
BLDG BUILDING
BRKR BREAKER
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CONN CONNECTION
CT CURRENT TRANSFORMER
DET(S) DETAIL(S)
DIAG DIAGRAM
DISC DISCONNECT
DWG(S) DRAWING(S)
EA EACH
EM EMERGENCY
ENCL ENCLOSURE
EXST EXISTING
F/A FIRE ALARM
FL FLOOR
FLUOR FLUORESCENT
FXTR FIXTURE
GEN GENERATOR
GND GROUND
HP HORSE POWER
HZ HERTZ
INCAND INCANDESCENT
INSTL INSTALLATION
J-BOX JUNCTION BOX
K KILO
KV KILO VOLT
KVA KILO VOLT AMPERE
LTG LIGHTING
MAG MAGNETIC
MAX MAXIMUM
MIN MINIMUM OR MINUTE
MTG MOUNTING
NO NUMBER
O/H OVER HEAD
PH PHASE
PNLBD PANELBOARD
PRIM PRIMARY
PWR POWER
Q'TY QUANTITY
RCPT RECEPTACLE
REQ'D REQUIRED
SCHED SCHEDULE
SEC SECONDARY
SPEC SPECIFICATION
STD STANDARD
SW SWITCH
TEL TELEPHONE
TYP TYPICAL
U/G UNDERGROUND
V VOLT
VA VOLT AMPERE
W WATT
W/ WITH
XFMR TRANSFORMER
& AND
CABNET TYPE, RATED WATT ON LTG SCHEDULE
LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER
HOMERUN CIRCUIT TO PANELBOARD
TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING
ABBREVIATION
THE COTNRACTOR SHALL SUBMIT A SHOP DRAWING OF HVAC SYSTEM
IN ACCORDANCE WITH SEQUENCE OF OPERATION INDICATED ON THE
MECHANICAL DRAWINGS.
ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2-#12AWG
WIRES IN 16C CONDUIT UNLESS OTHERWISE INDICATED.
THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR
ELECTRICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.
FMCP
FTR
ANTENNA
AUXILIARY
DESCRIPTION
F
TELEPHONE OUTLET
SYMBOL
CTC CATV SYSTEM CABINET
CATV OUTLET
ADDRESSABLE FA MANUAL PULL STATION
WP
F M
TTC
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
MOUNTED TYPE
F/A & MASS NOTIFICATION SPEAKER "WP" WALL
STROBES
WALL MOUNTED SPEAKER /COMBO. (FA+MNS)VISUAL
CONNECTION
BUILDING TRANSMITTER UNIT FOR FIRE ALARM
SYSTEM
F
WIRING FOR TELEPHONE LINET
BRANCH CIRCUIT, EXPOSED ON CEILING OR WALL
WIRING CONCEALED IN THE CEILING AND WALL
F/M
WP
TYPE WITH PLUG
SINGLE RECEPTACLE, 3P-4W-30A-125/250V, GROUNDING
TYPE WITH PLUG
SINGLE RECEPTACLE, 3P-4W-50A-125/250V, GROUNDING
L
W/EMERGENCY UNIT
WIRING TO UPSTAIR OR DOWNSTAIR
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
L
L
THE GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE
WIDTH OF DUCT EXCAVATION.
AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.
TO THEIR ORIGINAL CONDITION AND OPERATION DURING
ALL DAMAGED AREA INCLUDING SODDING, UTILITIES, STRUCTURES
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING
CIRCUIT INTERRUPTER TYPE,WEATHER PROOF
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUND FAULT
CIRCUIT INTERRUPTER TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUND FAULT
EXIT LIGHT, SINGLE FACE, WALL MOUNTED TYPE
(CEILING MOUNTED TYPE W/ARROW)
TELEPHONE TERMINAL CABINET
STEEL CONDUIT
F…