0011201716

a. This is a Non-Work Plan Task Order for the follow ing Area I & II, MA IDIQ Contractors only.

Contract Number: W91QVN-18-D-0021, 0022, 0023, 0024, 0025, 0026, 0027, 0028, 0030, 0031, 0032, 0034, 0035, 0040,0042, 0043, 0044, 0045, 0046, 0047, 0048, 0049, 0050, 0051, 0052, 0162

b. If the contractor is unable to submit the proposal in response to this RFP, the contractor shall submit the “No-offer letter” by closing date and time specified in the solicitation

MR. SON, U KAP 315-755-3387

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

07-Sep-2018

(RFP)

(IFB)

X

CALL:

Repair Building S-156 Including Fire Sprinkler System, K-16

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________150 calendar days after receiving aw ard, X notice to proceed. This performance period is mandatory, X negotiable. (See _________________________Section F

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES X NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________ copies to perform the w ork required are due at the place specified in Item 8 by ___________ local time ______________17 Sep 2018 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______240 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

411TH CONTRACTING SUPPORT BRIGADE, KOREA

SERVICES DIV, UNIT #15289

APO AP 96271

UNITED STATES

W91QVN

PAGE OF PAGES

1 OF

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

03:00 PM (hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

191107

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: TEL: FAX:

W91QVN18R0207 26

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

Section A - Solicitation/Contract Form

SUBJECT TO THE AVAILABILITY OF END-OF YEAR FUNDS (SAEF)

"FUNDS ARE NOT PRESENTLY AVAILABLE FOR THIS ACQUISITION. NO CONTRACT AWARD

WILL BE MADE UNTIL APPROPRIATED FUNDS ARE MADE AVAILABLE."

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Job

K WORK

FFP

Repair Building S-156 including Fire Sprinkler System, K-16 (PWO #191107) FOB: Destination

PURCHASE REQUEST NUMBER: 0011201716

PSC CD: 5670

NET AMT

0002 1 Job

L WORK

FFP

Repair Building S-156 including Fire Sprinkler System, K-16 (PWO #191107) FOB: Destination

PURCHASE REQUEST NUMBER: 0011201716

PSC CD: 5670

0003 1 Lot Estimated cost for war hazard

FFP

is zero(0).

FOB: Destination

Section C - Descriptions and Specifications

TECHNICAL PROVISIONS - I

STATEMENT OF WORK

PWO TITLE LOCATION

191107 Repair Building S-156 K-16

1. DESCRIPTION: Contractor shall provide all labor, tools, equipment, supplies, and any other resources necessary to accomplish the scope of work contained herein and as included in the drawings and specifications.

2. PERFORMANCE PERIOD: The contractor shall complete this project within 150 days after NTP is issued.

3. PRINCIPAL FEATURES: This project includes, but will not be limited to, the following principal features:

A. Repair and Maintenance ("K" work)

1) Civil:

a) Replace sidewalk.

b) Replace trash bin.

c) Restore solid sodding.

d) Replace concrete curb and gravel drain.

e) Replace 2.4m height chain link fence and personnel gate.

f) Paint on existing all metal surfaces.

g) Restore concrete sidewalk and ditch.

h) Dispose removed all construction debris to outside of compound.

2) Architecture:

a) Replace all existing deteriorated floor vinyl composition tiles (VCT) with new PVC tiles including vinyl cove bases (VCB).

b) Replace all existing deteriorated ceramic floor & wall tiles with new including tile accessories, metal lath, mortar bed and waterproofing in bathroom & shower room.

c) Replace all existing deteriorated stair rubber tiles with new.

d) Replace all existing deteriorated all gypsum wall board (GWB) walls with new including metal studs and soundproof insulations (STC 45).

e) Replace all existing deteriorated acoustic ceiling systems with new including metal suspension system.

f) Replace all existing deteriorated GWB ceiling systems with new including ceiling suspension system.

g) Replace all existing deteriorated doors and door frames with new including hardware.

h) Replace all existing deteriorated windows and window frames with new including hardware, insect screens, and horizontal mini blinds. Windows shall be aluminum thermal break type blast window, including 8.75 thick clear laminated glass + 12 thick air space + 6 thick tinted low-e tempered pair glass system (SHGC: Max 0.4). Blinds shall be fireproof type.

i) Replace all existing deteriorated wooden window sills with new (natural color, oak).

j) Replace existing deteriorated standing seam metal roof system with new including all accessories and flashing, etc.

k) Paint all required interior and exterior surfaces as scheduled.

l) Replace all existing deteriorated kitchenette systems with new including base & upper cabinets.

m) Replace all existing deteriorated wooden hanger rails with new at bedrooms.

n) Replace all existing deteriorated wooden shelf cabinets with new at walk-in closets including shelves and rods.

o) Replace existing pipe chases and pipe covers with new for mechanical and electrical work.

p) Replace all existing deteriorated toilet accessories and vanity cabinets with new.

q) Replace all existing deteriorated stainless steel laundry shelves with new.

r) Replace all existing deteriorated Fire Extinguisher Cabinet (FEC) with new.

s) Replace all existing deteriorated metal shelves with mop racks with new in janitor rooms.

t) Replace all existing deteriorated access doors with new on walls & ceilings.

u) Replace all existing deteriorated interior and exterior signage with new.

v) Replace all existing deteriorated air intake louvers for fan coil units with new.

w) Install new sprinkler valve room at first floor as shown on the 1st floor plan.

x) Paint on existing metal storage bins and replace deteriorated existing plywood with new 18 thick.

plywood including plastic laminated film.

y) Replace existing door locks with new cardkey system (ONITY, HT-24 or approved equal).

Provide 200 EA. of blank cards, One (1) EA. of cardkey producing equipment, One (1) EA. of notebook computer including control software for DPW. Remove all existing cardkey locksets carefully and turn in to DPW.

3) Mechanical

a) Replace deteriorated existing air handling units (2ea), panel type fan coil units and ceiling mounted fan coil unit (Remain the fan coil units installed in the bedroom), finned tube radiators (3ea), unit heaters (2ea), roof exhaust fans, dampers, valves, ducts, pipes, insulations, diffusers, control line associated with equipment replacement, and all associated accessories, for HVAC system (heating, ventilating and air conditioning system) as shown on drawings. (Mechanical Room Excluded.)

b) Repair the HVAC system by installing new range hoods, ducts, caps and all associated accessories as shown on drawings.

c) Perform DALT (Duct Air Leakage Test) and T.A.B. (Testing, Adjusting, and Balancing) after construction to verify if the HVAC System works properly.

d) Replace deteriorated existing domestic cold and hot water piping system, sewer and vent piping system including plumbing fixtures, and all associated accessories, for plumbing system as shown on drawings. (Mechanical room excluded.)

NOTE :

Control work must be performed by the Johnson Controls Inc. (JCI), and all control work should be connected with the existing system. Prior to replacing window status switch and wiring for fan coil unit as shown on the drawing, MATOC contractor shall verify existing condition, and coordinate with JCI and K-16 DPW. Window status switch were installed and operated by JCI under energy savings performance contract (ESPC) and are JCI's properties. Contractor shall perform the contractual work with JCI's service team for replace and re-commissioning of control work. Contact information of JCI is 02-2027-4006 / www.johnsoncontrols.kr

The contractor shall verify existing conditions for new work such as equipment & service clearance, equipment pad size, installation locations, and additional items.

If the existing duct size is different from the drawing. The duct should be constructed according to the existing duct size.

If the contractor is going to construction during the cooling/heating season the contractor shall provide the temporary cooling or heating system to the entire building.

4) Electrical

a) Replace deteriorated existing lighting fixtures, exit lights, exterior lights, light switches, photo cell controlled lighting contactor, wires and conduits with new.

b) Replace existing receptacles and cover plates, circuit breakers indicated in drawing, power wiring & conduits with new.

c) Replace deteriorated existing magnetic motor starters, junction boxes, control system, wires and conduits for mechanical system with new.

d) Replace deteriorated fire alarm control system with new addressable fire alarm control and mass notification system panel, manual pull station, smoke detector & relay module, building transmitter, antenna, visual signal strobes, microphone, speaker (wattage as required) device, local operating console and associated wiring and conduit.

e) Replace deteriorated existing telephone outlets with cover plates with new.

f) Replace existing CATV pull boxes, outlets with cover plates and associated wiring & conduit with new.

g) Remove and reinstall existing CCTV cameras & monitoring system with associated wiring and conduit.

h) Remove and reinstall existing occupancy sensors, thermostats and window status switches.

i) Replace existing control wiring for lighting and fan coil unit with new.

B. Construction/Alteration ("L" work)

1) Civil:

a) Provide 100mm (4”) DIA PVC water pipe with post indicator valve & guard post, and all necessary accessories including thrust blocks, fitting.

2) Mechanical:

a) Install new automatic fire protection sprinkler system, and all associated accessories, for fire protection system as shown on drawings.

b) Install new electric unit heater, and all associated accessories, for heating system of valve room as shown on drawings.

TECHNICAL PROVISIONS – II

TECHNICAL DETAIL SPECIFICATIONS

GENERAL: The specification sections listed below, but not limited to, are applicable to this project. The specifications are from the “Standard Technical Specifications for O&MA Projects, Korea, Revision 1” (2014 OMA SPECS, REVISION 1), dated 20151030, located on the 411th CSB Web Page, http://www.usfk.mil/Resources/ContractingwithUSFK.aspx. The electronic version of the specifications is Acrobat® PDF format and can be read with the Acrobat Reader® software.

STANDARD TECHNICAL SPECIFICATIONS FOR O&MA

PROJECT TABLE OF CONTENTS

DIVISION 01 – GENERAL REQUIREMENTS

01 30 00 ADMINISTRATIVE REQUIREMENTS

01 32 01.00 10 PROJECT SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS

01 45 00.00 10 QUALITY CONTROL

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 58 00 PROJECT IDENTIFICATION

01 78 00 CLOSEOUT SUBMITTALS

01 78 23 OPERATION AND MAINTENANCE DATA

DIVISION 02 – EXISTING CONDITIONS

02 41 00 DEMOLITION AND DECONSTRUCTION

DIVISION 03 – CONCRETE

03 11 13.00 10 STRUCTURAL CAST-IN-PLACE CONCRETE FORMING

03 15 00.00 10 CONCRETE ACCESSORIES

03 20 00.00 10 CONCRETE REINFORCING

03 30 00 CAST-IN-PLACE CONCRETE

03 30 53 MISCELLANEOUS CAST-IN-PLACE CONCRETE

DIVISION 04 – MASONRY

04 20 00 MASONRY

DIVISION 05 – METALS

05 50 13 MISCELLANEOUS METAL FABRICATIONS

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 10 ROUGH CARPENTRY

06 20 00 FINISH CARPENTRY

DIVISION 07 – THERMAL AND MOISTURE PROTECTION

07 21 16 MINERAL FIBER BLANKET INSULATION

07 22 00 ROOF AND DECK INSULATION

07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS

07 41 13 METAL ROOF PANEL

07 60 00 FLASHING AND SHEET METAL

07 92 00 JOINT SEALANTS

DIVISION 08 – OPENINGS

08 11 13 STEEL DOORS AND FRAMES

08 14 00 WOOD DOORS

08 51 13 ALUMINUM WINDOWS

08 71 00 DOOR HARDWARE

08 81 00 GLAZING

08 07 16 FRAGMENT RETENTION FILM FOR GLASS

DIVISION 09 - FINISHES

09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD

09 22 36 LATH

09 29 00 GYPSUM BOARD

09 30 00 CERAMIC TILE, QUARRY TILE, AND PAVER TILE

09 51 00 ACOUSTICAL CEILINGS

09 65 00 RESILIENT FLOORING

09 90 00 PAINTS AND COATINGS

DIVISION 10 – SPECIALITIES

10 14 01 EXTERIOR SIGNAGE

10 14 02 INTERIOR SIGNAGE

10 21 13 TOILET COMPARTMENTS

10 28 13 TOILET ACCESSORIES

DIVISION 12 – FURNISHINGS

12 21 00 WINDOW BLINDS

12 32 00 MANUFACTURED WOOD CASEWORK

12 36 00 COUNTERTOPS

DIVISION 13 – SPECIAL CONSTRUCTION

13 48 00.00 10 SEISMIC PROTECTION FOR MECHANICAL EQUIPMENT

DIVISION 21 – FIRE SUPPRESSION

21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION

DIVISION 22 – PLUMBING

22 00 00 PLUMBING, GENERAL PURPOSE

DIVISION 23 – HEATING, VENTILATING, AND AIR CONDITIONING

23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS

23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER

BUILDING CONTROL SYSTEMS

23 82 02.00 10 UNITARY HEATING AND COOLING EQUIPMENT

DIVISION 26 – ELECTRICAL

26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS

26 20 00 INTERIOR DISTRIBUTION SYSTEM

26 51 00 INTERIOR LIGHTING

DIVISION 27 – COMMUNICATIONS

27 54 00.00 20 COMMUNITY ANTENNA TELEVISION (CATV) SYSTEMS

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM

13 48 00 SEISMIC PROTECTION FOR MISCELLANEOUS EQUIPMENT

DIVISION 31 – EARTHWORK

31 00 00 EARTHWORK

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 01 16.17 COLD MILLING OF BITUMINOUS PAVEMENTS

32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN

RIGID PAVEMENTS

32 11 16.16 BASE COURSE FOR RIGID AND SUBBASE COURSE FOR

PERVIOUS PAVING

32 11 23 AGGREGATE AND/OR GRADED-CRUSHED AGGREGATE

BASE COURSE

32 12 10 BITUMINOUS TACK AND PRIME COATS

32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS

32 13 11 CONCRETE PAVEMENT FOR AIRFIELDS AND OTHER

HEAVY DUTY PAVEMENTS

32 16 13 CONCRETE SIDEWALK AND CURBS AND GUTTER

32 17 24.00 10 PAVEMENT MARKINGS

32 92 23 SODDING

DIVISION 33 - UTILITIES

33 11 00 WATER DISTRIBUTION

W91QVN18R0207

TECHNICAL PROVISIONS - III

SPECIAL CONDITIONS

1. GENERAL: In addition to the requirements specified under "GENERAL PROVISIONS" for the Fixed Price Construction Contract for this project, the Contractor shall comply with the following "SPECIAL CONDITIONS" which form a part of the contract.

2. WORK HOURS: The work will be accomplished from 0730 hours through 1730 hours, from 1 October through 30 April and from 0730 hours through 1930 hours from 1 May through 30 September, Mondays through Saturdays, except for Korean Legal Holidays: Any proposed change in working hours should be approved by the Contracting Officer (KO) and Contracting Officer's Representative (COR).

The contractor will not be permitted any construction work during scheduled (15 days in March and 15 days in August) and unscheduled training/exercises. The contractor shall remove heavy equipment and field offices from CP Tango and K-16 training sites during the training/exercises periods.

3. WINTERIZATION: The contractor may be required to perform weather sensitive work during the winter season, which may cause additional costs to be incurred for the contractor. These additional costs are the contractor’s responsibility in the event you are required to work during the winter. Your responsibility regarding the preparation of the proposal is to reflect these additional costs in your proposal.

4. ESCORT PRIVILEGE: The contractor shall be responsible for requesting escorting privileges on base passes for Project Manager, Quality Control Manager, Safety Specialist and Foremen. The maximum number of escorted employee will be three persons and the number of escorted vehicle will be one. The contractor shall ensure that the escorting employee has full control of all escorted individuals at all times. Any individual found on the installation unescorted will be removed from the installation and the escort employee’s escorting privileges will be withdrawn. Any individual removed from this installation will not be authorized further access to this installation.

5. DISPOSAL OF CONSTRUCTION DEBRIS/WASTE MATERIALS: The Contractor shall be required to dispose all construction debris and waste materials in strict accordance with disposal requirements of Section 024100, Demolition and Deconstruction, and local laws and regulations at the Contractor’s responsibility and his own expense. The waste/unsalvageable materials shall be disposed at the location(s) approved and designated by the local authorities.

6. SUBMITTALS: The Contractor shall process submittals in accordance with Section 013300 – SUBMITTAL PROCEDURES. Specific submittal requirements are shown on attached document entitled, “SUBMITTAL REGISTER”, Enclosure 1.

Section F - Deliveries or Performance

CLAUSES INCORPORATED BY FULL TEXT

52.211-10 COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK (APR 1984)

The Contractor shall be required to (a) commence work under this contract within 10 calendar days after the date the Contractor receives the notice to proceed, (b) prosecute the work diligently, and (c) complete the entire work ready for use not later than 150 calendar days after notice to proceed (NTP) is issued.

* The time stated for completion shall include final cleanup of the premises.

(End of clause)

Section H - Special Contract Requirements

ANTITERRORISM/OPERATIONS SECURITY REVIEW COVER SHEET

A. AT Level I Training. This standard language is for contractor employees with an area of performance within an Army controlled installation, facility or area. All contractor employees, to include subcontractor employees, requiring access Army installations, facilities and controlled access areas shall complete AT Level I awareness training within 20 calendar days after contract start date or effective date of incorporation of this requirement into the contract, whichever is applicable. The contractor shall submit certificates of completion for each affected contractor employee and subcontractor employee, to the COR or to the contracting officer, if a COR is not assigned, within 10 calendar days after completion of training by all employees and subcontractor personnel. AT level I awareness training is available at the following website: http://jko.jten.mil.

B. Access and General Protection/Security Policy and Procedures. This standard language is for contractor employees with an area of performance within Army controlled installation, facility, or area. Contractor and all associated sub-contractors employees shall provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.

C. iWATCH Training. This standard language is for contractor employees with an area of performance within an Army controlled installation, facility or area. The contractor and all associated sub-contractors shall brief all employees on the local iWATCH program (training standards provided by the requiring activity ATO). This local developed training will be used to inform employees of the types of behavior to watch for and instruct employees to report suspicious activity to the COR. This training shall be completed within 10 calendar days of contract award and within 10 calendar days of new employees commencing performance with the results reported to the COR NLT 10 calendar days after contract award.

D. Requirement for OPSEC Training. Per AR 530-1 Operations Security, the contractor employees must complete Level I OPSEC Awareness training. New employees must be trained within 30 calendar days of their reporting for duty and annually thereafter.

OPSEC training is available at the following website: http://cdsetrain.dtic.mil/opsec/

Section J - List of Documents, Exhibits and Other Attachments

LIST OF APPLICABLE CONTRACT DRAWINGS

GENERAL: The work shall conform to the following contract drawings and OMA standard detail drawings, 2014 (dated 30 November 2015), located on the 411th CSB Web Page, http://www.usfk.mil/Resources/ContractingwithUSFK.aspx all of which form a part of the specifications.

Ring No. Sheet No. Description Date

1 T-01 Title Sheet 5 Jun 18

CIVIL

2 C-01 Project Location Plan & General Note 5 Jun 18

3 C-02 Site Layout Plan & Scope of Work 5 Jun 18

4 C-03 Details 5 Jun 18

5 C-04 Trash Collection Bin - 1 5 Jun 18

6 C-05 Trash Collection Bin - 2 5 Jun 18

7 C-06 Trash Collection Bin - 3 5 Jun 18

8 C-07 Trash Collection Bin - 4 5 Jun 18

ARCHITECTURAL

9 A-01 General Notes, Scope of Works 5 Jun 18

10 A-02 1st Floor Plan and 2nd Floor Plan 5 Jun 18

11 A-03 3rd Floor Plan & Roof Plan 5 Jun 18

12 A-04 Unit Plan, Wall Sections and Details 5 Jun 18

13 A-05 Building Elevations 5 Jun 18

14 A-06 Building Sections 5 Jun 18

15 A-07 Interior & Exterior Finish Schedule 5 Jun 18

16 A-08 Door & Window Schedule 5 Jun 18

17 A-09 Exterior Wall Sections 5 Jun 18

18 A-10 Interior Wall Sections 5 Jun 18

19 A-11 Interior Elevations, Toilet Accessory Schedule 5 Jun 18

20 A-12 Roof Details 5 Jun 18

21 A-13 Signage’s Schedule 5 Jun 18

22 A-14 Miscellaneous Details

MECHANICAL

23 M-01 Legend & Abbreviations 5 Jun 18

24 M-02 General Notes & Scope of Work 5 Jun 18

25 M-03 Equipment Schedule 5 Jun 18

26 M-04 Exist/Removal Plan (1st., 2nd. & 3rd. Floor) 5 Jun 18

27 M-05 New HVAC Plan (1st. Floor) & Enlarged Partial Plan 5 Jun 18

28 M-06 New HVAC Plan (2nd. Floor) 5 Jun 18

29 M-07 New HVAC Plan (3rd. Floor) 5 Jun 18

30 M-08 Section 5 Jun 18

31 M-09 New HVAC Piping Plan (1st. Floor) 5 Jun 18

32 M-10 New HVAC Piping Plan (2nd. Floor) 5 Jun 18

33 M-11 New HVAC Piping Plan (3rd. Floor) 5 Jun 18

34 M-12 New HVAC Piping Isometric Diagram 5 Jun 18

35 M-13 Controls-1 5 Jun 18

36 M-14 Controls-2 5 Jun 18

37 M-15 New Domestic Water Piping Plan (1st. FL.) & Enlarged Partial Plans

5 Jun 18

38 M-16 New Domestic Water Piping Plan (2nd. Floor) 5 Jun 18

39 M-17 New Domestic Water Piping Plan (3rd. Floor) 5 Jun 18

40 M-18 New Domestic Water Piping Isometric Diagram 5 Jun 18

41 M-19 New Sewer & Vent Piping Plan (1st. Floor) 5 Jun 18

42 M-20 New Sewer & Vent Piping Plan (2nd. & 3rd. Floor) 5 Jun 18

43 M-21 New Sewer & Vent Piping Isometric Diagram 5 Jun 18

44 M-22 New Fire Protection Piping Plan (1st. FL.) & Enlarged Partial Plan

5 Jun 18

45 M-23 New Fire Protection Piping Plan (2nd. Floor) 5 Jun 18

46 M-24 New Fire Protection Piping Plan (3rd. Floor) 5 Jun 18

47 M-25 Details-1 5 Jun 18

48 M-26 Details-2 5 Jun 18

49 M-27 Details-3 5 Jun 18

50 M-28 Details-4 5 Jun 18

51 M-29 Details-5 5 Jun 18

ELECTRICAL

52 E-01 Legend, General Notes and Scope of Work 5 Jun 18

53 E-02 1st/2nd. Floor Lighting Plan 5 Jun 18

54 E-03 3rd. Floor Lighting Plan & “A”, “B”, “C” Module Lighting Plan

5 Jun 18

55 E-04 Lighting Fixture Details 5 Jun 18

56 E-05 Lighting Fixture Schedule 5 Jun 18

57 E-06 1st/2nd. Floor Power Plan 5 Jun 18

58 E-07 3rd. Floor Power Plan & “A”, “B”, “C” Module Power Plan 5 Jun 18

59 E-08 Panel Board Schedule-1 5 Jun 18

60 E-09 Panel Board Schedule-2 5 Jun 18

61 E-10 1st/2nd. Floor Telephone System Plan 5 Jun 18

62 E-11 3rd. Floor Telephone System Plan & Tel. System Riser Diagram

5 Jun 18

63 E-12 1st/2nd. Floor CATV System Plan 5 Jun 18

64 E-13 3rd. Floor CATV System Plan CATV System Riser Diagram 5 Jun 18

65 E-14 1st/2nd. Floor Fire Alarm Control/Mass Notification System Plan

5 Jun 18

66 E-15 3rd. Floor Fire Alarm Control/Mass Notification System Plan 5 Jun 18

67 E-16 New Fire Alarm/Mass Notification System Diagram 5 Jun 18

SUBMITTAL REGISTER

NOTE 1. See the attachment.

NOTE 2. The Submittal Register in Section J above, identifies the documentation that will be made available for approval and review by the Government in the performance of this task order. It is the contractor's responsibility that this data is in compliance with the corresponding OMA specification that is referenced.

Section K - Representations, Certifications and Other Statements of Offerors

52.203-2 CERTIFICATE OF INDEPENDENT PRICE DETERMINATION (APR 1985)

(a) The offeror certifies that --

(1) The prices in this offer have been arrived at independently, without, for the purpose of restricting competition, any consultation, communication, or agreement with any other offeror or competitor relating to –

(i) Those prices,

(ii) The intention to submit an offer, or

(iii) The methods of factors used to calculate the prices offered:

(2) The prices in this offer have not been and will not be knowingly disclosed by the offeror, directly or indirectly, to any other offeror or competitor before bid opening (in the case of a sealed bid solicitation) or contract award (in the case of a negotiated solicitation) unless otherwise required by law; and

(3) No attempt has been made or will be made by the offeror to induce any other concern to submit or not to submit an offer for the purpose of restricting competition.

(b) Each signature on the offer is considered to be a certification by the signatory that the signatory --

(1) Is the person in the offeror's organization responsible for determining the prices offered in this bid or proposal, and that the signatory has not participated and will not participate in any action contrary to subparagraphs (a)(1) through (a)(3) of this provision; or

(2) (i) Has been authorized, in writing, to act as agent for the following principals in certifying that those principals have not participated, and will not participate in any action contrary to subparagraphs (a)(1) through (a)(3) of this provison ______________________________________________________ (insert full name of person(s) in the offeror's organization responsible for determining the prices offered in this bid or proposal, and the title of his or her position in the offeror's organization);

(ii) As an authorized agent, does certify that the principals named in subdivision (b)(2)(i) above have not participated, and will not participate, in any action contrary to subparagraphs (a)(1) through (a)(3) above; and

(iii) As an agent, has not personally participated, and will not participate, in any action contrary to subparagraphs (a)(1) through (a)(3) of this provision.

(c) If the offeror deletes or modifies subparagraph (a)(2) of this provision, the offeror must furnish with its offer a signed statement setting forth in detail the circumstances of the disclosure.

(End of Provision)

252.209-7999 Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony Conviction under any Federal Law

REPRESENTATION BY CORPORATIONS REGARDING AN UNPAID DELINQUENT TAX LIABILTIY

OR A FELONY CONVICTION UNDER ANY FEDERAL LAW (DEVIATION 2012-00004) (JAN 2012)

(a) In accordance with sections 8124 and 8125 of Division A of the Consolidated Appropriations Act, 2012, (Pub. L. 112-74) none of the funds made available by that Act may be used to enter into a contract with any corporation that-

(1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless the agency has considered suspension or debarment of the corporation and made a determination that this further action is not necessary to protect the interests of the Government.

(2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless the agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government.

(b) The Offeror represents that –

(1) It is ( ) is not ( ) a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with authority responsible for collecting the tax liability,

(2) It is ( ) is not ( ) a corporation that was convicted of a felony criminal violation under a federal law within the preceding 24 months.

(End of provision)

5152.204-4032 REPRESENTATIONS AND CERTIFICATIONS

(a) SUBCONTRACTING:

If the offeror contemplates subcontracting, it must obtain prior written approval of subcontractor from the PCO or ACO, and list below: (1) the names and addresses of the subcontractor(s), (2) the type of subcontracting, and (3) the estimated price for each subcontract.

(b) AFFILIATED OFFERORS:

(1) Business concerns are affiliates of each other when, either directly or indirectly, one concern controls or has the power to control the other, or a third party controls or has the power to control both.

(2) Each offeror shall furnish, below, the following information:

(i) Whether the offeror has any affiliates;

(ii) The names and addresses of all affiliates of the offeror; and

(iii) The names and addresses of all persons and concerns exercising control or ownership of the offeror and any or all of its affiliates, and whether they are common officers, directors, stockholders holding controlling interest, or otherwise.

AFFILIATED CONCERNS. : (Name, location and, in detail, controlling interest in each)

(c) PRINCIPAL OWNER(S) OR STOCKHOLDER(S):

Each offeror shall list below the name(s) and address(es) of the principal owner(s) or stockholder(s) of the company and percentage of ownership. If a major portion is publicly traded and/or otherwise widely distributed, state that, with the percentage so affected.

(d) STANDARDS OF CONDUCT CERTIFICATION:

This is to certify that, to the best of my knowledge and belief, except as described below, no representative of this firm who deals with US Government employees on any aspect of this procurement is a former US Government employee, to include former US military personnel. I understand that this certification is continuing in nature and places a duty on me and my firm to notify the Contracting Officer of any additional individual(s) who fit the above description prior to the individual's assuming duties.

(i) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

(ii) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

(iii) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

Firm ____________________________________________________ Name _____________________________________________________ Signature __________________________________________________

Title _____________________________________________________ Date of Execution ____________________________________________

(e) TAXES:

(1) References:

(i) Contract clause entitled "FAR 52.229-06 Taxes—Foreign Fixed-Price Contracts (Jan 1991)."

(ii) US-ROK Status of Forces Agreement (SOFA), Articles IX and XVI.

(iii) ROK Customs Law, Law No. 1976, promulgated on 29 November 1967, as amended.

(iv) ROK Value Added Tax Law, Law No. 2934, promulgated on 22 December 1976 (effective date 1 July 1977), as amended.

(v) ROK Special Excise Tax Law, Law No. 2935, promulgated on 22 December 1976 (effective date 1 July 1977), as amended.

(2) Contractor shall state the types and estimated amount of taxes that would normally apply to such transactions but are excluded from this proposal.

(i) Customs Tax (except for ROK MND-funded contracts or delivery orders):

Name Number Cost/Unit of Item of Units w/o Tax % of Tax Tax/Unit Tax Total

This item will be imported specifically for this contract? Yes _____ No _____

(ii) Special Excise Tax:

Name Number Cost/Unit of Item of Units w/o Tax % of Tax Tax/Unit Tax Total

Name of item manufacturer

(iii) Value Added Tax (VAT):

Input VAT on materials purchased for this contract. 10% _____ Input VAT on transportation leased/rented for this contract.10% _____ Input VAT on equipment leased/rented for this contract. 10% _____ Input VAT on services purchased for this contract. 10% _____ Output VAT on total contract amount. 10% _____

(iv) Special Excise (Petroleum) Tax:

No. of U/P Liters w/o Tax Tax/Unit Total Tax Amount Regular Gasoline ________ (L) ________ w________ w_____________ Premium Gasoline ________ (L) ________ w________ w_____________ Diesel ________ (L) ________ w________ w_____________ Other ________ (L) ________ w________ w_____________

(v) Education Tax.

(3) Name of the oil company from which POL products will be purchased:

Oil Company: _________________________________________ (Name only)

(4) I certify by this submission that all supplies and services to be purchased for this contract have been proposed exclusive of Value Added Tax, applicable Customs Tax (except ROK MND-funded contracts and delivery orders), Special Excise Tax, and Education Tax.

Signed (Chop)

(f) CERTIFICATIONS AND REPRESENTATIONS

By submitting an offer, each offeror agrees to be bound by all certifications and representations in this solicitation.

The Government reserves the right to require any and all certifications and representations to be completed and signed in hard copy by the successful offeror prior to contract award. Failure of an offeror to complete the certifications and representations within the time directed by the Contracting Officer may result in a determination that the contractor is not a responsible offeror for this acquisition.

Section L - Instructions, Conditions and Notices to Bidders

SECTION L

1. GENERAL INSTRUCTIONS FOR PREPARATION OF PROPOSAL:

The Government intends to award without discussion, but reserves the right to conduct discussions if deemed necessary and to establish a competitive range for efficiency in accordance with FAR 52.215-1(f)(4).

Offeror(s) may, at the discretion of the Government, be asked to provide more information and clarification regarding their proposals. The Government may make a final determination as to whether an offer is acceptable or unacceptable solely based on the proposals as submitted, without requesting any further information. However, if it is deemed necessary the Government may, at its sole discretion, request additional information clarifying but not substantially changing any proposal as submitted.

2. SUBMISSION OF PROPOSAL:

i) FBO SUBMISSION REQUIRED: Offers shall be submitted to the Federal Business Opportunities (FBO) website (https://www.fbo.gov/), or if FBO is not available, email to ukap.son1.ln@mail.mil with the evidence document such as screen shot. The FBO unavailability is limited to only FBO server problem not individual failure/problem.

All questions should be emailed to ukap.son1.ln@mail.mil within five (5) days after the solicitation is issued.

ii) CLOSING DATE: The electronic offer shall be submitted by 1500 hours, KST on the closing date of RFP.

iii) SUBMISSION REQUIREMENTS

a) PRICING PROPOSAL: The pricing proposal must clearly indicate prices for each Contract Line Item Number in Section B - Supplies or Services and Prices.

b) DETAILED OFFER BREAKDOWN: The detailed offer breakdown must clearly identify all costs that can materially impact the statement of work.

c) SECTION K - Representations, Certifications and Other Statements of Offerors SECTION K-TAXES: Offerors must complete all tax portions of SECTION K. The offeror shall review all expenses to ensure that all applicable taxes are excluded from the overall price. In addition, offerors shall propose exemptions of specific ROK taxes that are legitimate, attributable to the contract, and authorized by the applicable stated references.

SECTION K-OTHER: Offerors must complete all Non-Tax related portions of SECTION K.

iv) COMPLIANCE WITH SOLICITATION: Failure to submit the above requirements under SECTION L may be grounds for determining the proposal to be non-compliant. For example, if a detailed offer breakdown is not submitted, the contracting officer will be unable to find the offeror's pricing proposal acceptable and the offeror's proposal will be ineligible for award. Non-compliance will only be cured if the government holds discussions as detailed in SECTION L.

52.236-27 SITE VISIT (CONSTRUCTION) (FEB 1995) – ALTERNATE I (FEB 1995)

(a) The clauses at 52.236-2, Differing Site Conditions, and 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation. Accordingly, offerors or quoters are urged and expected to inspect the site where the work will be performed.

When: 13 Sep 2018, 15:00 Where: B156, K16 POC: Mr. Pak, Sang Hyon, DSN: 724‐4212

(End of provision)

5152.236-4011 CONSTRUCTION PRICE RANGE

Pursuant to FAR 36.204 the estimated price range is between $ 1,000,000 and $5,000,000.

Section M - Evaluation Factors for Award

BASIS OF AWARD

Electronic offers submitted by 1500 hours, KST on the closing date of RFP shall be considered timely.

i) EVALUATION CRITERIA The pricing proposal shall be evaluated to determine whether it is complete and reasonable. A complete and reasonable pricing proposal will be deemed acceptable.

The detailed offer breakdown will be used by the contracting officer to determine whether proposed prices are complete and reasonable. A detailed offer breakdown may be used by the contracting officer to determine whether an offeror is able to complete the requirements under the contract, and/or whether discussions will be conducted pursuant to instructions to the offerors.

ii) SECTION K - Representations, Certifications and Other Statements of Offerors

a. SECTION K-TAXES will be evaluated to determine whether it is complete. In addition, propose exemptions of specific ROK taxes will be evaluated to determine whether they are legitimate, attributable to the contract, authorized, and reasonable. A complete SECTION-K that only proposes exemptions of specific ROK taxes that are legitimate, attributable to the contract, necessary to complete the Task Order, do not improperly overstate any proposed tax exemption, authorized, and reasonable will be deemed acceptable.

b. SECTION K-OTHER will be evaluated to determine whether it is complete. A complete SECTION K-OTHER will be deemed acceptable.

BASIS FOR AWARD: Award shall be made to the responsible offeror submitting the lowest priced offer that is evaluated as acceptable for all evaluation criteria.