A02_Attachment1-7SpecificationsNWP0001.pdf
PDF 158 KB Posted
- Attached to
- MA IDIQ GENERAL CONSTRUCTION Federal contract opportunity
- Solicitation number
- W91QVN18R0006
About this file
A02 Attachment1-7SpecificationsNWP0001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W91QVN-18-R-0006-0001.pdf | ||
| H1_Attachment1-5DrawingsforMechNWP0001.pdf | ||
| H1_Attachment1-4DrawingsforElecNWP0001.pdf | ||
| H1_Attachment2-2DrawingsWorkPlan0002.pdf | ||
| A02_Attachment3OfferBreakdownFormat.pdf | ||
| A02_Attachment2-1SOWWorkPlan0002-Revision-1_2_Nov_16.pdf | ||
| H1_Attachment1-6DrawingsforFireProNWP0001.pdf | ||
| H1_Attachment1-3DrawingsforCivilNWP0001.pdf | ||
| A02_Attachment1-1SOWNonWorkPlan0001.-Revision_2_Nov_16.pdf | ||
| H1_Attachment1-2DrawingsforArchNWP0001.pdf | ||
| W91QVN18R0006.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FY09 SMYU 06-1094, STANDARD DESIGN OF DORMITORY
BUILDING TYPE 1366, OSAN AIR BASE, KOREA
PROJECT TABLE OF CONTENTS
DIVISION 01 - GENERAL REQUIREMENTS
01 22 00.00 31 PAYMENT
01 32 01 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
01 35 29 SAFETY AND OCCUPATIONAL HEALTH REQUIREMENTS
01 45 01 QUALITY CONTROL SYSTEM (QCS)
01 45 05 CONTRACTOR QUALITY CONTROL
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND MISCELLANEOUS
PROVISIONS
01 57 20.00 ENVIRONMENTAL PROTECTION
01 62 35 RECYCLED / RECOVERED MATERIALS
01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
01 78 02 CLOSEOUT SUBMITTALS
01 78 23 OPERATION AND MAINTENANCE DATA
DIVISION 02 - EXISTING CONDITIONS
02 41 00 DEMOLITION AND DECONSTRUCTION
DIVISION 03 - CONCRETE
03 30 04 CONCRETE FOR MINOR STRUCTURES
DIVISION 05 - METALS
05 50 00 METAL: MISCELLANEOUS AND FABRICATIONS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 20 00 FINISH CARPENTRY
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 14 00 FLUID-APPLIED WATERPROOFING
07 21 16 MINERAL FIBER BLANKET INSULATION
07 60 00 FLASHING AND SHEET METAL
07 61 13 STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 39 55 BLAST RESISTANT GLAZED ALUMINUM DOORS AND FRAMES
08 56 55 BLAST RESISTANT ALUMINUM WINDOWS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL AND DOOR LOUVERS
DIVISION 09 - FINISHES
09 06 90 COLOR SCHEDULE
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 GYPSUM BOARD
PROJECT TABLE OF CONTENTS Page 1
LG
강조
LG
강조
LG
강조
LG
강조
LG
강조
LG
강조
09 30 00 CERAMIC TILE
09 51 00 ACOUSTICAL CEILINGS
09 65 00 RESILIENT FLOORING
09 68 00 CARPET
09 90 00 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
10 14 02 INTERIOR SIGNAGE
10 28 13 TOILET ACCESSORIES
DIVISION 12 - FURNISHINGS
12 21 00 WINDOW BLINDS
12 35 30.00 31 RESIDENTIAL CABINETS AND COUNTERTOPS
DIVISION 13 - SPECIAL CONSTRUCTION
13 48 00.00 10 SEISMIC PROTECTION FOR MECHANICAL EQUIPMENT
13 48 00 SEISMIC PROTECTION FOR MISCELLANEOUS EQUIPMENT
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
22 08 00 COMMISSIONING OF PLUMBING SYSTEMS
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 08 00.00 10 COMMISSIONING OF HVAC SYSTEMS
23 09 23 DIRECT DIGITAL CONTROL FOR HVAC AND OTHER LOCAL BUILDING
SYSTEMS
23 23 00 REFRIGERANT PIPING
23 38 00 MECHANICAL DRYER VENTING SYSTEM
23 52 00 HEATING BOILERS
23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE
23 64 26 CHILLED, CHILLED-HOT, AND CONDENSER WATER PIPING SYSTEMS
23 82 02.00 10 UNITARY HEATING AND COOLING EQUIPMENT
DIVISION 26 - ELECTRICAL
26 00 00 BASIC ELECTRICAL MATERIALS AND METHODS
26 05 48 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 23 00 SWITCHBOARDS
26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS
26 51 00 INTERIOR LIGHTING
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
DIVISION 31 - EARTHWORK
PROJECT TABLE OF CONTENTS Page 2
LG
강조
31 00 00 EARTHWORK
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 11 16 SUBBASES FOR FLEXIBLE PAVING
32 11 23 AGGREGATE BASE COURSE
32 12 10 BITUMINOUS TACK AND PRIME COATS
32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS
32 16 13 CONCRETE SIDEWALKS, CURBS, AND GUTTERS
32 17 24.00 10 PAVEMENT MARKINGS
DIVISION 33 - UTILITIES
33 11 00 WATER DISTRIBUTION
33 56 10 FACTORY-FABRICATED FUEL STORAGE TANKS
33 58 00 LEAK DETECTION FOR FUELING SYSTEMS
33 61 00.00 31 PREFABRICATED UNDERGROUND HEATING/COOLING DISTRIBUTION
SYSTEM
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 3
SECTION TABLE OF CONTENTS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
SECTION 07 61 13
STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 GENERAL REQUIREMENTS
1.3.1 Structural Standing Seam Metal Roof
1.3.2 Qualifications
1.3.2.1 Manufacturer
1.3.2.2 Installer
1.4 DESIGN ANALYSIS
1.4.1 Design Criteria
1.4.2 Dead Loads
1.4.3 Live Loads
1.4.3.1 Concentrated Loads
1.4.3.2 Uniform Loads
1.4.4 Roof Snow Loads
1.4.5 Wind Loads
1.4.6 Thermal Loads
1.4.7 Framing Members Supporting the SSSMR System
1.4.8 Roof Panels Design
1.4.9 Accessories and Their Fasteners
1.5 PERFORMANCE REQUIREMENTS
1.6 DELIVERY AND STORAGE
1.7 WARRANTIES
1.7.1 Contractor's Weathertightness Warranty
1.7.2 Manufacturer's Material Warranties.
1.8 COORDINATION MEETING
PART 2 PRODUCTS
2.1 ROOF PANELS
2.1.1 Steel Panels
2.1.2 Aluminum Panels
2.2 CONCEALED ANCHOR CLIPS
2.3 ACCESSORIES
2.4 FASTENERS
2.4.1 Screws
2.4.2 Bolts
2.4.3 Structural Blind Fasteners
2.5 SUBPURLINS
2.6 FACTORY COLOR FINISH
2.6.1 Salt Spray Test
2.6.2 Formability Test
2.6.3 Accelerated Weathering, Chalking Resistance and Color Change
2.6.4 Humidity Test
2.6.5 Impact Resistance
2.6.6 Abrasion Resistance Test
2.6.7 Specular Gloss
SECTION 07 61 13 Page 1
2.6.8 Pollution Resistance
2.7 INSULATION
2.7.1 Blanket Insulation
2.7.2 Glass Mat Gypsum Roof Board
2.8 INSULATION RETAINERS
2.9 SEALANT
2.10 GASKETS AND INSULATING COMPOUNDS
2.11 VAPOR RETARDER
2.11.1 Vapor Retarders as Integral Facing
2.11.2 Vapor Retarders Separate from Insulation
2.12 EPDM RUBBER BOOTS
2.13 PREFABRICATED CURBS AND EQUIPMENT SUPPORTS
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Field Forming of Panels for Unique Area
3.1.2 Subpurlins
3.1.3 Roof Panel Installation
3.1.4 Concealed Anchor Clips
3.2 INSULATION INSTALLATION
3.2.1 Blanket Insulation
3.3 PROTECTION OF VAPOR RETARDER FROM ROOF DECK
3.4 VAPOR RETARDER INSTALLATION
3.4.1 Integral Facing on Blanket Insulation
3.4.2 Polyethylene Vapor Retarder
3.5 CLEANING AND TOUCH-UP
-- End of Section Table of Contents --
SECTION 07 61 13 Page 2
SECTION 07 61 13
STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA ADM1 (2005; Errata 2005) Aluminum Design Manual
AMERICAN IRON AND STEEL INSTITUTE (AISI)
AISI SG-973 (2002) Cold-Formed Steel Design Manual
AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)
ASCE 7 (2005; Suppl 1) Minimum Design Loads for Buildings and Other Structures
ASTM INTERNATIONAL (ASTM)
ASTM A 463/A 463M (2009 Standard Specification for Steel Sheet, Aluminum-Coated
ASTM A 653/A 653M (2009) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A 792/A 792M (2009) Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process
ASTM B 209M (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)
ASTM C 1177/C 1177M (2008) Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing
ASTM C 1289 (2008) Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
ASTM C 518 (2004) Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
ASTM C 991 (2008e1) Flexible Glass Fiber Insulation
SECTION 07 61 13 Page 3 for Metal Buildings
ASTM D 1308 (2002; R 2007) Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Organic Finishes
ASTM D 1654 (2008) Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments
ASTM D 2244 (2007) Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
ASTM D 2247 (2002) Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity
ASTM D 2794 (1993; R 2004) Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)
ASTM D 3359 (2009) Measuring Adhesion by Tape Test
ASTM D 4214 (2007) Standard Test Method for Evaluating the Degree of Chalking of Exterior Paint Films
ASTM D 4397 (2009) Standard Specification for Polyethylene Sheeting for Construction, Industrial, and Agricultural Applications
ASTM D 522 (1993a; R 2008) Mandrel Bend Test of Attached Organic Coatings
ASTM D 523 (2008) Standard Test Method for Specular Gloss
ASTM D 5894 (2005) Standard Practice for Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry Cabinet and a UV/Condensation Cabinet)
ASTM D 610 (2008) Evaluating Degree of Rusting on Painted Steel Surfaces
ASTM D 714 (2002el) Standard Test Method for Evaluating Degree of Blistering of Paints
ASTM D 968 (2005el) Standard Test Methods for Abrasion Resistance of Organic Coatings by Falling Abrasive
ASTM E 1592 (2005) Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference
ASTM E 84 (2009a) Standard Test Method for Surface
SECTION 07 61 13 Page 4
Burning Characteristics of Building Materials
ASTM E 96/E 96M (2005) Standard Test Methods for Water Vapor Transmission of Materials
ASTM G 154 (20006) Standard Practice for Operating Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials
STEEL JOIST INSTITUTE (SJI)
SJI Specs & Tables (2006) Standard Specifications and Load Tables for Steel Joists and Joist Girders
KOREAN INDUSTRIAL STANDARDS (KS)
KS D 3506 (2007) Hot-dip zinc-coated steel sheets and coils
KS D 6701 (2002) Aluminum and Aluminum Alloy Sheets and Plates, Strips and Coiled Sheets
KS M 3503 (2002) Polyethylene films for agriculture
KS M 3809 (2006) Rigid polyurethane foam for thermal insulation
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Structural Standing Seam Metal Roof; G
Metal roofing drawings and specifications and erection drawings;
shop coating and finishing specifications; and other data as necessary to clearly describe design, materials, sizes, layouts, standing seam configuration, construction details, provisions for thermal movement, line of panel fixity, fastener sizes and spacings, sealants and erection procedures. Drawings shall reflect the intent of the architectural detailing using the manufacturer's proprietary products and fabricated items as required. The SSSMR system shop drawings shall be provided by the metal roofing manufacturer.
SD-03 Product Data
Design Analysis; G
Design analysis signed by a Registered Professional Engineer employed by the SSSMR manufacturer. The design analysis shall include a list of the design loads, and complete calculations for the support system (when provided by the Contractor), roofing
SECTION 07 61 13 Page 5 system and its components; valley designs, gutter/downspout calculations, screw pullout test results, and shall indicate how expected thermal movements are accommodated.
Qualifications
Qualifications of the manufacturer and installer.
SD-04 Samples
Accessories
One sample of each type of flashing, trim, closure, thermal spacer block, cap and similar items. Size shall be sufficient to show construction and configuration.
Roof Panels
One piece of each type to be used, 225 mm (9 inches) long, full width.
Factory Color Finish
Three 75 by 125 mm (3 by 5 inches) samples of each type and color.
Fasteners
Two samples of each type to be used, with statement regarding intended use. If so requested, random samples of bolts, nuts, and washers as delivered to the job site shall be taken in the presence of the Contracting Officer and provided to the Contracting Officer for testing to establish compliance with specified requirements.
Insulation
One piece, 300 by 300 mm (12 by 12 inches), of each type and thickness to be used, with a label indicating the rated permeance (if faced) and R-values. The flame spread, and smoke developed rating shall be shown on the label or provided in a letter of certification.
Gaskets and Insulating Compounds
Two samples of each type to be used and descriptive data.
Sealant
One sample, approximately 0.5 kg (1 pound), and descriptive data.
Concealed Anchor Clips
Two samples of each type used.
Subpurlins
One piece, 225 mm (9 inches) long.
SECTION 07 61 13 Page 6
EPDM Rubber Boots
One piece of each type.
SD-06 Test Reports
Wind Uplift Resistance; G
The report shall include the following information:
a. Details of the SSSMR system showing the roof panel cross-section with dimensions and thickness.
b. Details of the anchor clip, dimensions, and thickness.
c. Type of fasteners, size, and the number required for each connection.
d. Purlins/subpurlins size and spacing used in the test.
e. Description of the seaming operation including equipment used.
f. Maximum allowable uplift pressures. These pressures are determined from the ultimate load divided by a factor of safety equal to 1.65.
g. Any additional information required to identify the SSSMR system tested.
h. Signature and seal of an independent registered engineer who witnessed the test.
SD-07 Certificates
Structural Standing Seam Metal Roof
a. Certification that the actual thickness of uncoated sheets used in SSSMR components including roofing panels, subpurlins, and concealed anchor clips complies with specified requirements.
b. Certification that materials used in the installation are mill certified.
c. Previous certification of SSSMR system tested under the Corps of Engineers' Standard Test Method in lieu of ASTM E 1592 testing.
d. Certification that the sheets to be furnished are produced under a continuing quality control program and that a representative sample consisting of not less than three pieces has been tested and has met the quality standards specified for factory color finish.
e. Certification of installer. Installer certification shall be furnished.
f. Warranty certificate. At the completion of the project
SECTION 07 61 13 Page 7 the Contractor shall furnish signed copies of the 5-year Warranty for Structural Standing Seam Metal Roof (SSSMR) System, a sample copy of which is attached to this section, [and] the 20-year Manufacturer's Material Warranties, [and the manufacturer's 20-year system weathertightness warranty].
Insulation
Certificate attesting that the polyisocyanurate insulation furnished for the project contains recovered material, and showing an estimated percent of such recovered material.
1.3 GENERAL REQUIREMENTS
The Contractor shall furnish a commercially available roofing system which satisfies all requirements contained herein and has been verified by load testing and independent design analyses to meet the specified design requirements.
1.3.1 Structural Standing Seam Metal Roof
The SSSMR system covered under this specification shall include the entire roofing system; the standing seam metal roof panels, fasteners, connectors, roof securement components, and assemblies tested and approved in accordance with ASTM E 1592. In addition, the system shall consist of panel finishes, slip sheet, insulation, vapor retarder, all accessories, components, and trim and all connections with roof panels. This includes roof penetration items such as vents, curbs, skylights; interior or exterior gutters and downspouts; eaves, ridge, hip, valley, rake, gable, wall, or other roof system flashings installed and any other components specified within this contract to provide a weathertight roof system.
1.3.2 Qualifications
1.3.2.1 Manufacturer
The SSSMR system shall be the product of a manufacturer who has been in the practice of manufacturing and designing SSSMR systems for a period of not less than 3 years and has been involved in at least five projects similar in size and complexity to this project.
1.3.2.2 Installer
The installer shall be certified by the SSSMR system manufacturer to have experience in installing at least three projects that are of comparable size, scope and complexity as this project for the particular roof system furnished. The installer may be either employed by the manufacturer or be an independent installer.
1.4 DESIGN ANALYSIS
The design of the SSSMR system shall be provided by the Contractor as a complete system. Members and connections not indicated on the drawings shall be designed by the Contractor. Roof panels, components, transitions, accessories, and assemblies shall be supplied by the same roofing system manufacturer.
SECTION 07 61 13 Page 8
1.4.1 Design Criteria
Design criteria shall be in accordance with ASCE 7.
1.4.2 Dead Loads
The dead load shall be the weight of the SSSMR system. Collateral loads such as sprinklers, mechanical and electrical systems, and ceilings shall not be attached to the panels.
1.4.3 Live Loads
1.4.3.1 Concentrated Loads
The panels and anchor clips shall be capable of supporting a 1335 N (300 pound) concentrated load. The concentrated load shall be applied at the panel midspan and will be resisted by a single standing seam metal roof panel assumed to be acting as a beam. The undeformed shape of the panel shall be used to determine the section properties.
1.4.3.2 Uniform Loads
The panels and concealed anchor clips shall be capable of supporting a minimum uniform live load of 960 Pa (20 psf).
1.4.4 Roof Snow Loads
The design roof snow loads shall be as shown on the contract drawings.
1.4.5 Wind Loads
The design wind uplift pressure for the roof system shall be as shown on the contract drawings. The design uplift force for each connection assembly shall be that pressure given for the area under consideration, multiplied by the tributary load area of the connection assembly. The safety factor listed below shall be applied to the design force and compared against the ultimate capacity. Prying shall be considered when figuring fastener design loads.
a. Single fastener in each connection.........3.00
b. Two or more fasteners in each connection...2.25
1.4.6 Thermal Loads
Roof panels shall be free to move in response to the expansion and contraction forces resulting from a total temperature range of 104 degrees C (220 degrees F) during the life of the structure.
1.4.7 Framing Members Supporting the SSSMR System
Any additions/revisions to framing members supporting the SSSMR system to accommodate the manufacturer/fabricator's design shall be the Contractor's responsibility and shall be submitted for review and approval. New or revised framing members and their connections shall be designed in accordance with AISI SG-973 or SJI Specs & Tables. Maximum deflection under applied live load, snow, or wind load shall not exceed 1/180 of the span length.
SECTION 07 61 13 Page 9
1.4.8 Roof Panels Design
Steel panels shall be designed in accordance with AISI SG-973. Aluminum panels shall be designed in accordance with AA ADM1. The structural section properties used in the design of the panels shall be determined using the unloaded shape of the roof panels. The calculated panel deflection from concentrated loads shall not exceed 1/180 of the span length. The calculated panel deflection under applied live load, snow, or wind load shall not exceed 1/180 times the span length. Deflections shall be based on panels being continuous across three or more supports.
Deflection shall be calculated and measured along the major ribs of the panels.
1.4.9 Accessories and Their Fasteners
Accessories and their fasteners shall be capable of resisting the specified design wind uplift forces and shall allow for thermal movement of the roof panel system. Exposed fasteners shall not restrict free movement of the roof panel system resulting from thermal forces. There shall be a minimum of two fasteners per clip. Single fasteners with a minimum diameter of 9 mm (3/8 inch) will be allowed when the supporting structural members are prepunched or predrilled.
1.5 PERFORMANCE REQUIREMENTS
The SSSMR shall be tested for wind uplift resistance in accordance with ASTM E 1592; SSSMR systems previously tested and approved by the Corps of Engineers' STANDARD TEST METHOD FOR STRUCTURAL PERFORMANCE OF SSMRS BY UNIFORM STATIC AIR PRESSURE DIFFERENCE may be acceptable. Two tests shall be performed. Test 1 shall simulate the edge condition with one end having crosswise restraint and other end free of crosswise restraint. The maximum span length for the edge condition shall be 750 mm (30 inches). Test 2 shall simulate the interior condition with both ends free of crosswise restraint. The maximum span length for the interior condition shall be 1.5 m (5 feet). External reinforcement, such as clamps on the ribs, shall not be installed to improve uplift resistance. Bolts through seams shall not be installed.
1.6 DELIVERY AND STORAGE
Materials shall be delivered to the site in a dry and undamaged condition and stored out of contact with the ground. Materials shall be covered with weathertight coverings and kept dry. Storage conditions shall provide good air circulation and protection from surface staining.
1.7 WARRANTIES
The SSSMR system shall be warranted as outlined below. Any emergency temporary repairs conducted by the owner shall not negate the warranties.
1.7.1 Contractor's Weathertightness Warranty
The SSSMR system shall be warranted by the Contractor on a no penal sum basis for a period of five years against material and workmanship deficiencies; system deterioration caused by exposure to the elements and/or inadequate resistance to specified service design loads, water leaks, and wind uplift damage. The SSSMR system covered under this warranty shall include the entire roofing system including, but not limited to, the standing seam metal roof panels, fasteners, connectors, roof
SECTION 07 61 13 Page 10 securement components, and assemblies tested and approved in accordance with ASTM E 1592. In addition, the system shall consist of panel finishes, slip sheet, insulation, vapor retarder, all accessories, components, and trim and all connections with roof panels. This includes roof penetration items such as vents, curbs, and skylights; interior or exterior gutters and downspouts; eaves, ridge, hip, valley, rake, gable, wall, or other roof system flashings installed and any other components specified within this contract to provide a weathertight roof system; and items specified in other sections of these specifications that are part of the SSSMR system.
All material and workmanship deficiencies, system deterioration caused by exposure to the elements and/or inadequate resistance to specified design loads, water leaks and wind uplift damage shall be repaired as approved by the Contracting Officer. See the attached Contractor's required warranty for issue resolution of warrantable defects. This warranty shall warrant and cover the entire cost of repair or replacement, including all material, labor, and related markups. The Contractor shall supplement this warranty with written warranties from the installer and system manufacturer, which shall be submitted along with Contractor's warranty; however, the Contractor shall be ultimately responsible for this warranty. The Contractor's written warranty shall be as outlined in attached WARRANTY FOR STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM, and shall start upon final acceptance of the facility. It is required that the Contractor provide a separate bond in an amount equal to the installed total roofing system cost in favor of the owner (Government) covering the Contractor's warranty responsibilities effective throughout the five year Contractor's warranty period for the entire SSSMR system as outlined above.
1.7.2 Manufacturer's Material Warranties.
The Contractor shall furnish, in writing, the following manufacturer's material warranties which cover all SSSMR system components such as roof panels, anchor clips and fasteners, flashing, accessories, and trim, fabricated from coil material:
a. A manufacturer's 20 year material warranty warranting that the aluminum, zinc-coated steel, aluminum-zinc alloy coated steel or aluminum-coated steel as specified herein will not rupture, structurally fail, fracture, deteriorate, or become perforated under normal design atmospheric conditions and service design loads.
Liability under this warranty shall be limited exclusively to the cost of either repairing or replacing nonconforming, ruptured, perforated, or structurally failed coil material.
b. A manufacturer's 20 year exterior material finish warranty on the factory colored finish warranting that the finish, under normal atmospheric conditions at the site, will not crack, peel, or delaminate; chalk in excess of a numerical rating of eight, as determined by ASTM D 4214 test procedures; or change color in excess of five CIE or Hunter Lab color difference (delta E) units in accordance with ASTM D 2244. Liability under this warranty is exclusively limited to refinishing with an air-drying version of the specified finish or replacing the defective coated material.
c. A roofing system manufacturer's 20 year, non-prorated, system weathertightness warranty.
1.8 COORDINATION MEETING
A coordination meeting shall be held 30 days prior to the first submittal, SECTION 07 61 13 Page 11 for mutual understanding of the Structural Standing Seam Metal Roof (SSSMR) System contract requirements. This meeting shall take place at the building site and shall include representatives from the Contractor, the roof system manufacturer, the roofing supplier, the erector, the SSSMR design engineer of record, and the Contracting Officer. All items required by paragraph SUBMITTALS shall be discussed, including applicable standard manufacturer shop drawings, and the approval process. The Contractor shall coordinate time and arrangements for the meeting.
PART 2 PRODUCTS
2.1 ROOF PANELS
Panels shall be steel or aluminum and shall have a factory color finish.
Length of sheets shall be sufficient to cover the entire length of any unbroken roof slope for slope lengths that do not exceed 9 m (30 feet).
When length of run exceeds 9 m and panel laps are provided, each sheet in the run shall extend over three or more supports. Sheets longer than 30 m (100 feet) may be furnished if approved by the Contracting Officer. Width of sheets shall provide not more than 600 mm (24 inches) of coverage in place. SSSMR system with roofing panels greater than 300 mm (12 inches) in width shall have standing seams rolled during installation by an electrically driven seaming machine. Height of standing seams shall be not less than 28 mm (1-1/4 inches).
2.1.1 Steel Panels
Steel panels shall be zinc-coated steel conforming to ASTM A 653/A 653M or KS D 3506; aluminum-zinc alloy coated steel conforming to ASTM A 792/A 792M, AZ 55 coating; or aluminum-coated steel conforming to ASTM A 463/A 463M, Type 2, coating designation T2 65. Zinc, zinc-aluminum alloy or aluminum coated panels shall be 0.584 mm (0.023 inch) thick minimum. Panels shall be within 95 percent of reported tested thickness as noted in wind uplift resistance testing required in paragraph PERFORMANCE REQUIREMENTS. Prior to shipment, mill finish panels shall be treated with a passivating chemical to inhibit the formation of oxide corrosion products. Panels that have become wet during shipment and have started to oxidize shall be rejected.
2.1.2 Aluminum Panels
Alloy conforming to ASTM B 209M or KS D 6701, temper as required for the forming operation, minimum 0.8 mm (0.032 inch) thick.
2.2 CONCEALED ANCHOR CLIPS
Concealed anchor clips shall be the same as the tested roofing system.
Clip bases shall have factory punched or drilled holes for attachment.
Clips shall be made from multiple pieces with the allowance for the total thermal movement required to take place within the clip. Single piece clips may be acceptable when the manufacturer can substantiate that the system can accommodate the thermal cyclic movement under sustained live or snow loads.
2.3 ACCESSORIES
Flashing, trim, metal closure strips, caps and similar metal accessories shall be the manufacturer's standard products. Exposed metal accessories shall be finished to match the panels furnished. Molded closure strips
SECTION 07 61 13 Page 12 shall be bituminous-saturated fiber, closed-cell or solid-cell synthetic rubber or neoprene, or polyvinyl chloride premolded to match configuration of the panels and shall not absorb or retain water. The use of a continuous angle butted to the panel ends to form a closure will not be allowed.
2.4 FASTENERS
Fasteners for steel roof panels shall be zinc-coated steel, aluminum, corrosion resisting steel, or nylon capped steel, type and size specified below or as otherwise approved for the applicable requirements. Fasteners for aluminum roof panels shall be aluminum or corrosion resisting steel.
Fasteners for structural connections shall provide both tensile and shear ultimate strengths of not less than 3340 N (750 pounds) per fastener.
Fasteners for accessories shall be the manufacturer's standard. Exposed roof fasteners shall be sealed or have sealed washers on the exterior side of the roof to waterproof the fastener penetration. Washer material shall be compatible with the roofing; have a minimum diameter of 10 mm (3/8 inch) for structural connections; and gasketed portion of fasteners or washers shall be neoprene or other equally durable elastomeric material approximately 3 mm thick. Exposed fasteners for factory color finished panels shall be factory finished to match the color of the panels.
2.4.1 Screws
Screws for attaching anchor devices shall be not less than No. 14. Actual screw pull out test results shall be performed for the actual material gage and yield strength of the structural purlins or subpurlins to which the clip is to be anchored/attached. Other screws shall be as recommended by the manufacturer to meet the strength design requirements of the panels.
2.4.2 Bolts
Bolts shall be not less than 6 mm (1/4 inch) diameter, shouldered or plain shank as required, with locking washers and nuts.
2.4.3 Structural Blind Fasteners
Blind screw-type expandable fasteners shall be not less than 6 mm diameter.
Blind (pop) rivets shall be not less than 7 mm (9/32 inch) minimum diameter.
2.5 SUBPURLINS
Cold formed supporting structural members/subpurlins shall have a minimum thickness of 1.5 mm (0.059 inches) and a minimum tensile yield strength of 345 MPa (50000 psi). Hot rolled structural members shall have a minimum thickness of 6 mm (0.25 inches) and a minimum tensile yield strength of 248 MPa (36000 psi). Subpurlins shall be galvanized.
2.6 FACTORY COLOR FINISH
Panels shall have a factory applied polyvinylidene fluoride finish on the exposed side. The exterior finish shall consist of a baked-on topcoat with an appropriate prime coat. Color shall match the color indicated in Section 09 06 90 COLOR SCHEDULE. The exterior coating shall be a nominal
0.025 mm (1 mil) thickness consisting of a topcoat of not less than 0.018 mm (0.7 mil) dry film thickness and the paint manufacturer's recommended primer of not less than 0.005 mm (0.2 mil) thickness. The interior color
SECTION 07 61 13 Page 13 finish shall consist of the same coating and dry film thickness as the exterior or a nominal 0.025 mm (1 mil) thick PVF2 finish otherwise the same as the exterior. (Note: Where int surfaces are concealed behind insulation, liner panels provide only a galvanized primer coat.) The exterior color finish shall meet the test requirements specified below.
2.6.1 Salt Spray Test
A sample of the sheets shall withstand a cyclic corrosion test for a minimum of 2016 hours in accordance with ASTM D 5894, including the scribe requirement in the test. Immediately upon removal of the panel from the test, the coating shall receive a rating of not less than 10, no blistering, as determined by ASTM D 714; 10, no rusting, as determined by ASTM D 610; and a rating of 6, over 2 0 to 3.0 mm (1/16 to 1/8 inch) failure at scribe, as determined by ASTM D 1654.
2.6.2 Formability Test
When subjected to testing in accordance with ASTM D 522 Method B, 3 mm (1/8 inch) diameter mandrel, the coating film shall show no evidence of cracking to the naked eye.
2.6.3 Accelerated Weathering, Chalking Resistance and Color Change
A sample of the sheets shall be tested in accordance with ASTM G 154, test condition UVA-340 lamp, 4h UV at 60 degrees C (140 degrees F) followed by 4h CON at 50 degrees C (122 degrees F) for required total hours. The coating shall withstand the weathering test without cracking, peeling, blistering, loss of adhesion of the protective coating, or corrosion of the base metal. Protective coating with an adhesion rating less than 4B when tested in accordance with ASTM D 3359, Test Method B, shall be considered as an area indicating loss of adhesion. Following the accelerated weathering test, the coating shall have a chalk rating not less than No. 8 in accordance with ASTM D 4214 test procedures, and the color change shall not exceed 5 CIE or Hunter Lab color difference (delta E) units in accordance with ASTM D 2244. For sheets required to have a low gloss finish, the chalk rating shall be not less than No. 6 and the color difference shall be not greater than 7 units.
2.6.4 Humidity Test
When subjected to a humidity cabinet test in accordance with ASTM D 2247 for 1000 hours, a scored panel shall show no signs of blistering, cracking, creepage or corrosion.
2.6.5 Impact Resistance
Factory-painted sheet shall withstand direct and reverse impact in accordance with ASTM D 2794 13 mm (0.5 inch) diameter hemispherical head indenter, equal to 6.7 times the metal thickness in mm, expressed in Newton-meters (1.5 times the metal thickness in mils, expressed in inch-pounds), with no cracking.
2.6.6 Abrasion Resistance Test
When subjected to the falling sand test in accordance with ASTM D 968, Method A, the coating system shall withstand a minimum of 50 liters of sand before the appearance of the base metal. The term "appearance of base metal" refers to the metallic coating on steel or the aluminum base metal.
SECTION 07 61 13 Page 14
2.6.7 Specular Gloss
Finished roof surfaces shall have a specular gloss value of 10 or less at an angle of 85 degrees when measured in accordance with ASTM D 523.
2.6.8 Pollution Resistance
Coating shall show no visual effects when covered spot tested in a 10 percent hydrochloric acid solution for 24 hours in accordance with
ASTM D 1308.
2.7 INSULATION
Thermal resistance of insulation shall be not less than the R-values shown on the contract drawings. R-values shall be determined at a mean temperature of 24 degrees C (75 degrees F) in accordance with ASTM C 518.
Insulation shall be a standard product with the insulation manufacturer, factory marked or identified with insulation manufacturer's name or trademark and R-value. Identification shall be on individual pieces or individual packages. Blanket insulation shall have a facing as specified in paragraph VAPOR RETARDER. Insulation, including facings, shall have a flame spread not in excess of 75 and a smoke developed rating not in excess of 150 when tested in accordance with ASTM E 84. The stated R-value of the insulation shall be certified by an independent Registered Professional Engineer if tests are conducted in the insulation manufacturer's laboratory. Contractor shall comply with EPA requirements in accordance with Section 01 62 35 RECYCLED / RECOVERED MATERIALS.
2.7.1 Blanket Insulation
Blanket insulation shall conform to ASTM C 991.
2.7.2 Glass Mat Gypsum Roof Board
Glass mat gypsum roof board for use above the deck or insulation for thermal protection shall have a flame spread - 0, smoke developed - 0, shall be water resistant and have a compressive strength of 3.4 kPa (500 psi). Glass mat gypsum roof board shall conform to ASTM C 1177/C 1177M.
2.8 INSULATION RETAINERS
Insulation retainers shall be type, size, and design necessary to adequately hold the insulation and to provide a neat appearance. Metallic retaining members shall be nonferrous or have a nonferrous coating.
Nonmetallic retaining members, including adhesives used in conjunction with mechanical retainers or at insulation seams, shall have a fire resistance classification not less than that permitted for the insulation.
2.9 SEALANT
Sealants shall be elastomeric type containing no oil or asphalt. Exposed sealant shall be colored to match the applicable building color and shall cure to a rubberlike consistency. Sealant placed in the roof panel standing seam ribs shall be provided in accordance with the manufacturer's recommendations.
SECTION 07 61 13 Page 15
2.10 GASKETS AND INSULATING COMPOUNDS
Gaskets and insulating compounds shall be nonabsorptive and suitable for insulating contact points of incompatible materials. Insulating compounds shall be nonrunning after drying.
2.11 VAPOR RETARDER
2.11.1 Vapor Retarders as Integral Facing
Insulation facing shall have a permeability of 1.15 ng per Pa-second-square meter (0.02 perm) or less when tested in accordance with ASTM E 96/E 96M.
Facing shall be white reinforced polypropylene kraft laminate (PSK).
Facings and finishes shall be factory applied.
2.11.2 Vapor Retarders Separate from Insulation
Vapor retarder material shall be polyethylene sheeting conforming to ASTM D 4397 or KS M 3503. A single ply of 0.25 mm (10 mil) polyethylene sheet; or, at the Contractor's option, a double ply of 0.15 mm (6 mil) polyethylene sheet shall be used. A fully compatible polyethylene tape which has equal or better water vapor control characteristics than the vapor retarder material shall be provided. A cloth industrial duct tape in a utility grade shall also be provided to use as needed to protect the vapor retarder from puncturing.
2.12 EPDM RUBBER BOOTS
Flashing devices around pipe penetrations shall be flexible, one-piece devices molded from weather-resistant EPDM rubber. Rubber boot material shall be as recommended by the manufacturer. The boots shall have base rings made of aluminum or corrosion resisting steel that conform to the contours of the roof panel to form a weather-tight seal.
2.13 PREFABRICATED CURBS AND EQUIPMENT SUPPORTS
Prefabricated curbs and equipment supports shall be of structural quality, hot-dipped galvanized or galvanized sheet steel, factory primed and prepared for painting with mitered and welded joints. Integral base plates and water diverter crickets shall be provided. Minimum height of curb shall be 200 mm (8 inches) above finish roof. Curbs shall be constructed to match roof slope and to provide a level top surface for mounting of equipment. Curb flange shall be constructed to match configuration of roof panels. Curb size shall be coordinated, prior to curb fabrication, with the mechanical equipment to be supported. Strength requirements for equipment supports shall be coordinated to include all anticipated loads.
Flashings shall not be rigidly attached to underline structure.
PART 3 EXECUTION
3.1 INSTALLATION
Installation shall be in accordance with the manufacturer's erection instructions and drawings. Dissimilar materials which are not compatible when contacting each other shall be insulated by means of gaskets or insulating compounds. Molded closure strips shall be installed wherever roofing sheets terminate in open-end configurations, exclusive of flashings. The closure strip installation shall be weather-tight and sealed. Screws shall be installed with a clutching screw gun, to assure
SECTION 07 61 13 Page 16 screws are not stripped. Field test shall be conducted on each gun prior to starting installation and periodically thereafter to assure it is adjusted properly to install particular type and size of screw as recommended by manufacturer's literature. Improper or mislocated drill holes shall be plugged with an oversize screw fastener and gasketed washer;
however, sheets with an excess of such holes or with such holes in critical locations shall not be used. Exposed surfaces and edges shall be kept clean and free from sealant, metal cuttings, hazardous burrs, and other foreign material. Stained, discolored, or damaged sheets shall be removed from the site.
3.1.1 Field Forming of Panels for Unique Area
When roofing panels are formed from factory-color-finished steel coils at the project site, the same care and quality control measures that are taken in shop forming of roofing panels shall be observed. Rollformer shall be operated by the metal roofing manufacturer's representative. In cold weather conditions, preheating of the steel coils to be field formed shall be performed as necessary just prior to the rolling operations.
3.1.2 Subpurlins
Unless otherwise shown, subpurlins shall be anchored to the purlins or other structural framing members with bolts or screws. Attachment to the substrate (when provided) or to the panels is not permitted. The subpurlin spacing shall not exceed 750 mm (30 inches) on centers at the corner, edge and ridge zones, and 1500 mm (5 foot) maximum on centers for the remainder of the roof. Corner, edge, and ridge zones are as defined in ASCE 7.
3.1.3 Roof Panel Installation
Roof panels shall be installed with the standing seams in the direction of the roof slope. The side seam connections for installed panels shall be completed at the end of each day's work. Method of applying joint sealant shall conform to the manufacturer's recommendation to achieve a complete weather-tight installation. End laps of panels shall be provided in accordance with the manufacturer's instructions. Closures, flashings, EPDM rubber boots, roof curbs, and related accessories shall be installed according to the manufacturer's drawings. Fasteners shall not puncture roofing sheets except as provided for in the manufacturer's instructions for erection and installation. Expansion joints for the standing seam roof system shall be installed at locations indicated on the contract drawings and other locations indicated on the manufacturer's drawings.
3.1.4 Concealed Anchor Clips
Concealed anchor clips shall be fastened directly to the structural framing members. Attachment to the substrate (when provided) or to the metal deck is not permitted. The maximum distance, parallel to the seams, between clips shall be 750 mm (30 inches) on center at the corner, edge, and ridge zones, and 1500 mm (5 feet) maximum on centers for the remainder of the roof.
3.2 INSULATION INSTALLATION
Insulation shall be continuous over entire roof surface. Where expansion joints, terminations, and other connections are made, the cavity shall be filled with batt insulation with vapor retarder providing equivalent R-value and perm rating as remaining insulation. Insulation shall be
SECTION 07 61 13 Page 17 installed as indicated and in accordance with manufacturer's instructions.
3.2.1 Blanket Insulation
Blanket insulation shall be installed between and parallel to the purlins with tabs of a facer lapping on the top face of the purlins. Thermal blocks shall be provided over purlins, between clips. A second layer of unfaced insulation shall be added between purlins to provide full R-value.
Blanket insulation shall be supported by an integral facing or other commercially available support system.
3.3 PROTECTION OF VAPOR RETARDER FROM ROOF DECK
A cloth industrial duct tape shall be applied over the seams of metal roof decks, at penetration edges, and at surface areas exhibiting sharp burrs or similar protrusions. For other types of roof decks, cloth industrial duct tape shall be applied over irregularities which could potentially puncture polyethylene membrane.
3.4 VAPOR RETARDER INSTALLATION
3.4.1 Integral Facing on Blanket Insulation
Integral facing on blanket insulation shall have the facing lapped and sealed with a compatible tape to provide a vapor tight membrane.
3.4.2 Polyethylene Vapor Retarder
The polyethylene vapor retarder membrane shall be installed over the entire surface. A fully compatible polyethylene tape shall be used to seal the edges of the sheets to provide a vapor tight membrane. Sheet edges shall be lapped not less than 150 mm (6 inches). Sufficient material shall be provided to avoid inducing stresses in the sheets due to stretching or binding. All tears or punctures that are visible in the finished surface at any time during the construction process shall be sealed with polyethylene tape.
3.5 CLEANING AND TOUCH-UP
Exposed SSSMR systems shall be cleaned at completion of installation.
Debris that could cause discoloration and harm to the panels, flashings, closures and other accessories shall be removed. Grease and oil films, excess sealants, and handling marks shall be removed and the work shall be scrubbed clean. Exposed metal surfaces shall be free of dents, creases, waves, scratch marks, and solder or weld marks. Immediately upon detection, abraded or corroded spots on shop-painted surfaces shall be wire brushed and touched up with the same material used for the shop coat.
Factory color finished surfaces shall be touched up with the manufacturer's recommended touch up paint.
SECTION 07 61 13 Page 18
CONTRACTOR'S FIVE (5) YEAR NO PENAL SUM WARRANTY
FOR
STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
FACILITY DESCRIPTION_________________________________________________
BUILDING NUMBER:_____________________________________________________
CORPS OF ENGINEERS CONTRACT NUMBER:__________________________________
CONTRACTOR
CONTRACTOR:__________________________________________________________
ADDRESS:_____________________________________________________________
POINT OF CONTACT:____________________________________________________
TELEPHONE NUMBER:____________________________________________________
OWNER
OWNER:_______________________________________________________________
ADDRESS:_____________________________________________________________
POINT OF CONTACT:____________________________________________________
TELEPHONE NUMBER:____________________________________________________
CONSTRUCTION AGENT
CONSTRUCTION AGENT:__________________________________________________
ADDRESS:_____________________________________________________________
POINT OF CONTACT:____________________________________________________
TELEPHONE NUMBER:____________________________________________________
SECTION 07 61 13 Page 19
CONTRACTOR'S FIVE (5) YEAR NO PENAL SUM WARRANTY
FOR
STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
(continued)
THE SSSMR SYSTEM INSTALLED ON THE ABOVE NAMED BUILDING IS WARRANTED BY
_____________________________ FOR A PERIOD OF FIVE (5) YEARS AGAINST
WORKMANSHIP AND MATERIAL DEFICIENCES, WIND DAMAGE, STRUCTURAL FAILURE, AND
LEAKAGE. THE SSSMR SYSTEM COVERED UNDER THIS WARRANTY SHALL INCLUDE, BUT
SHALL NOT BE LIMITED TO, THE FOLLOWING: THE ENTIRE ROOFING SYSTEM,
MANUFACTURER SUPPLIED FRAMING AND STRUCTURAL MEMBERS, METAL ROOF PANELS,
FASTENERS, CONNECTORS, ROOF SECUREMENT COMPONENTS, AND ASSEMBLIES TESTED AND
APPROVED IN ACCORDANCE WITH ASTM E 1592. IN ADDITION, THE SYSTEM PANEL
FINISHES, SLIP SHEET, INSULATION, VAPOR RETARDER, ALL ACCESSORIES,
COMPONENTS, AND TRIM AND ALL CONNECTIONS ARE INCLUDED. THIS INCLUDES ROOF
PENETRATION ITEMS SUCH AS VENTS, CURBS, SKYLIGHTS; INTERIOR OR EXTERIOR
GUTTERS AND DOWNSPOUTS; EAVES, RIDGE, HIP, VALLEY, RAKE, GABLE, WALL, OR
OTHER ROOF SYSTEM FLASHINGS INSTALLED AND ANY OTHER COMPONENTS SPECIFIED
WITHIN THIS CONTRACT TO PROVIDE A WEATHERTIGHT ROOF SYSTEM; AND ITEMS
SPECIFIED IN OTHER SECTIONS OF THE SPECIFICATIONS THAT ARE PART OF THE SSSMR
SYSTEM.
ALL MATERIAL DEFICIENCIES, WIND DAMAGE, STRUCTURAL FAILURE, AND LEAKAGE
ASSOCIATED WITH THE SSSMR SYSTEM COVERED UNDER THIS WARRANTY SHALL BE
REPAIRED AS APPROVED BY THE CONTRACTING OFFICER. THIS WARRANTY SHALL COVER
THE ENTIRE COST OF REPAIR OR REPLACEMENT, INCLUDING ALL MATERIAL, LABOR, AND
RELATED MARKUPS. THE ABOVE REFERENCED WARRANTY COMMENCED ON THE DATE OF
FINAL ACCEPTANCE ON ____________________________ AND WILL REMAIN IN EFFECT
FOR STATED DURATION FROM THIS DATE.
SIGNED, DATED, AND NOTARIZED (BY COMPANY PRESIDENT)
(Company President) (Date)
SECTION 07 61 13 Page 20
CONTRACTOR'S FIVE (5) YEAR NO PENAL SUM WARRANTY
FOR
STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
(continued)
THE CONTRACTOR SHALL SUPPLEMENT THIS WARRANTY WITH WRITTEN WARRANTIES FROM
THE MANUFACTURER AND/OR INSTALLER OF THE SSSMR SYSTEM, WHICH SHALL BE
SUBMITTED ALONG WITH THE CONTRACTOR'S WARRANTY. HOWEVER, THE CONTRACTOR WILL
BE ULTIMATELY RESPONSIBLE FOR THIS WARRANTY AS OUTLINED IN THE SPECIFICATIONS
AND AS INDICATED IN THIS WARRANTY EXAMPLE.
EXCLUSIONS FROM COVERAGE
1. NATURAL DISASTERS, ACTS OF GOD (LIGHTNING, FIRE, EXPLOSIONS, SUSTAINED
WIND FORCES IN EXCESS OF THE DESIGN CRITERIA, EARTHQUAKES, AND HAIL).
2. ACTS OF NEGLIGENCE OR ABUSE OR MISUSE BY GOVERNMENT OR OTHER PERSONNEL,
INCLUDING ACCIDENTS, VANDALISM, CIVIL DISOBEDIENCE, WAR, OR DAMAGE CAUSED BY
FALLING OBJECTS.
3. DAMAGE BY STRUCTURAL FAILURE, SETTLEMENT, MOVEMENT, DISTORTION, WARPAGE,
OR DISPLACEMENT OF THE BUILDING STRUCTURE OR ALTERATIONS MADE TO THE BUILDING.
4. CORROSION CAUSED BY EXPOSURE TO CORROSIVE CHEMICALS, ASH OR FUMES
GENERATED OR RELEASED INSIDE OR OUTSIDE THE BUILDING FROM CHEMICAL PLANTS,
FOUNDRIES, PLATING WORKS, KILNS, FERTILIZER FACTORIES, PAPER PLANTS, AND THE
LIKE.
5. FAILURE OF ANY PART OF THE SSSMR SYSTEM DUE TO ACTIONS BY THE OWNER TO
INHIBIT FREE DRAINAGE OF WATER FROM THE ROOF AND GUTTERS AND DOWNSPOUTS OR
ALLOW PONDING WATER TO COLLECT ON THE ROOF SURFACE. CONTRACTOR'S DESIGN
SHALL INSURE FREE DRAINAGE FROM THE ROOF AND NOT ALLOW PONDING WATER.
6. THIS WARRANTY APPLIES TO THE SSSMR SYSTEM. IT DOES NOT INCLUDE ANY
CONSEQUENTIAL DAMAGE TO THE BUILDING INTERIOR OR CONTENTS WHICH IS COVERED BY
THE WARRANTY OF CONSTRUCTION CLAUSE INCLUDED IN THIS CONTRACT.
7. THIS WARRANTY CANNOT BE TRANSFERRED TO ANOTHER OWNER WITHOUT WRITTEN
CONSENT OF THE CONTRACTOR; AND THIS WARRANTY AND THE CONTRACT PROVISIONS WILL
TAKE PRECEDENCE OVER ANY CONFLICTS WITH STATE STATUTES.
SECTION 07 61 13 Page 21
CONTRACTOR'S FIVE (5) YEAR NO PENAL SUM WARRANTY
FOR
STRUCTURAL STANDING SEAM METAL ROOF (SSSMR) SYSTEM
(continued)
**REPORTS OF LEAKS AND SSSMR SYSTEM DEFICIENCIES SHALL BE RESPONDED TO WITHIN
48 HOURS OF RECEIPT OF NOTICE, BY TELEPHONE OR IN WRITING, FROM EITHER THE
OWNER OR CONTRACTING OFFICER.