HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OF
MOUNTING HEIGHTS ARE AS BELOW. MEASUREMENT IS TO CENTER OF OUTLET.
2-#14AWG WIRES IN 16mm CONDUIT, (FOR BELL CIRCUIT, 24V DC LINE)
DISTANCE OF 460mm.
FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING FIXTURE A MINIMUM
ALL WIRING SHALL BE CONCEALD ABOVE CEILING WHEN THE ROOM HAS CEILING.
US ORIGIN MATERIAL:
CONDUIT WHICH IS TO BE BONDED TO MAIN GROUNDING SYSTEM AT BOTH ENDS.
GROUNDING WIRE SHALL BE GREEN INSULATED COPPER WIRE IN RIGID GALVANIZED STEEL
WIRES IS INDICATED AS FOLLOW;
AND ONE (1)-#12AWG GROUND WIRE IN 16mm CONDUIT. A GREATER NUMBER OF
ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES TWO (2)-#12AWG WIRES
3-#12AWG WIRES AND 1-#12AWG GROUND WIRE IN 16mm CONDUIT.
4-#12AWG WIRES AND 1-#12AWG GROUND WIRE IN 16mm CONDUIT.
FIRE ALARM CONTROL PANEL----------------------------1520mm ABOVE FLOOR
LIGHTING FIXTURE--------------------SEE LIGHTING FIXTURE SCHEDULE
TOGGLE SWITCH-----------------------1220mm TO CENTER OF THE OUTLET
RECEPTACLE---------------------------460mm TO CENTER OUTLET
PANELBOARD, CIRCUIT BREAKER------------------------SEE SPECIFICATION
COMMUNCATION LINE) IN 16mm CONDUIT.
1-#18AWG SHIELDED CABLE TWISTED PAIR (FOR SMOKE/HEAT DETECTOR SENSOR
2-#14AWG WIRES (FOR SMOKE DETECTOR POWER LINE, 24VDC) AND
PAIR IN 16mm CONDUIT, A GREATER NUMBER OF WIRES IS INDICATED AS FOLLOWS:
CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES ONE(1)-#18AWG SHIELD CABLE TWISTED
FIRE ALARM CIRCUIT SHALL BE DOUBLE LOOF SYSTEM IN A SEPARATE CONDUIT AND ANY
T
T
2SET-4PAIR, CATEGORY 6 #24AWG CABLES IN 28mm CONDUIT
3SET-4PAIR, CATEGORY 6 #24AWG CABLES IN 28mm CONDUIT
#24 AWG CABLE IN 28mm CONDUIT A GREATER NUMBER OF CABLES IS INDICATED AS FOLLOWS;
ANY TELEPHONE CIRCUIT WITHOUT FURTURE DESIGNATION INDICATES 1 SET-4PAIR, CATEGORY 6
#24 AWG CABLE IN 28mm CONDUIT A GREATER NUMBER OF CABLES IS INDICATED AS FOLLOWS;
ANY TELEPHONE CIRCUIT WITHOUT FURTURE DESIGNATION INDICATES 1 SET-4PAIR, CATEGORY 6
L
CAULKING MATERIAL SHALL BE VERIFIED BY F&ES OFFICE PRIOR TO CONSTRUCTION.
BOTH SIDE OF FIRE WALLS, FIRE-PARTITIONS, AND FIRE-RATED PIPE CHASE WALLS.
ALL PIPE PENETRATIONS SHALL BE SEALED WITH FIRE RATED CAULKING MATERIAL ON
SPECIFICATIONS FOR O&MA PROJECTS, AND SPECIFICATIONS.
ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, FIRE CODE, TECHNICAL STANDARD
ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE NATIONAL
G E N E R A L N O T E S
CONSTRUCTION.
CONTRACTOR SHALL COORDINATE WITH AREA DPW. SIGNAL BRIGADE, CATV BEFORE
MANUAL PULL STATION----------------------------------1370mm ABOVE FLOOR
FIRE ALARM BELL---------------------------------------2130mm ABOVE FLOOR
NON-PCB TRANSFORMER CERTIFICATION FOR EACH TO BE INSTALLED TRANSFORMER
INSTALLED TRANSFORMER. NEW TRANSFORMER WILL BE INSTALLED ATFER COR’S APPROVAL FOR
SUBMIT TWO COPIES OF NON-PCB TRANSFORMER CERTIFICATION TO COR FOR EACH TO BE
BEFOER CONTRACTOR REPLACE/INSTALL ANY TRANSFORMER AT USAG DAEGU, CONTRACTOR SHALL
AND THE COLOR OF TOGGLE SWITCHES AND RECEPTACLE SHALL BE GRAY.
ALL COVER PLATES OF RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL METALLIC ONES
INDICATED ON THE DRAWINGS.
INTERNET SITE (http//www.cckbid.com). ALL NON-GENERIC US ORIGIN MATERIALS SHALL BE AS
DATED FEBRURY 2, 2004 (ELECTRONIC VERSION OF THIS DOCUMENT CAN BE FOUND AT
REGISTER OF IMA-KORO PAMPHLET 420-1 "INSPECTION OF CONSTRUCTION CONTRACTS
ALL GENERIC US ORIGIN MATERIALS SHALL BE AS OFF-SHORE IN THE GENERIC SUBMITAL
2W-4PAIR, CATEGORY 6 #24AWG CABLES IN 28mm CONDUIT
S C O P E O F W O R KL E G E N D
REMOVE EXST NEW
///// F
N
///// C
T-LT-L/////
F
N
C
S S S
COMMUNICATION
1.
4.
2.
5.
ELECTRICAL
LED PANEL AND DRIVER WITH EMERGENCY UNIT.
LED SQUARE LIGHTING FIXTURE, 120~277VAC, VARIOUS WATT
T-8 LAMPS AND ELECTRONIC BALLAST.
FLUORESCENT LIGHTING FIXTURE, 120VAC, WITH 2/ 25W TYPE
T-8 LAMPS AND ELECTRONIC BALLAST WITH EMERGENCY UNIT.
FLUORESCENT LIGHTING FIXTURE, 120VAC, WITH 2/ 25W TYPE
LED PANEL AND DRIVER WITH EMERGENCY UNIT.
LED FLAT LIGHTING FIXTURE, 120~277VAC, VARIOUS WATT
LED PANEL AND DRIVER.
LED SQUARE LIGHTING FIXTURE, 120~277VAC, VARIOUS WATT
EXIT LIGHT, DOUBLE FACE, WALL/CEILING MOUNT TYPE
PANELBOARD OR LOAD CENTER
SAFETY SWITCH
MAGNETIC SWITCH
RECEPTACLE, DUPLEX, 2P-3W-20A-125V, GRD’G TYPE.
GROUND-FAULT CIRCUIT-INTERRUPTING TYPE.
RECEPTACLE, DUPLEX, 2P-3W-20A-125V,
RECEPTACLE, DUPLEX, 2P-3W-20A-250V, GRD’G TYPE.
GROUNDING TYPE, WITH PLUG.
RECEPTACLE, SINGLE, 2P-3W-30A-250V,
TOGGLE SWITCH, 1P-20A-120V.
S S S333
3-WAY TOGGLE SWITCH, 2P-20A-120V.
WIRING CONCEALED IN CEILINGS AND WALL
F
N
C
T-L
WIRING CONCEALED IN FLOOR AND WALL
WIRING EXPOSED ON CEILINGS AND WALL
WIRING CONCEALED IN UNDERGROUND
HOMERUN CIRCUIT TO PANELBOARD OR ENCLOSURE
FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT
FIRE ALARM SIGNAL LINE CIRCUIT
CONTROL CIRCUIT
TELEPHONE AND LAN CIRCUIT
"AUTO-OFF-HAND" SELECTOR SWITCHH.O.AH.O.A H.O.A
PHOTO CONTROL, SPST 120VAC, 1000W
TS
1H
TS
1H
TIME SWITCH, 1 HOUR, 1P-120V-20A.
J J JUNCTION BOX
CCC
120VAC, 60HZ INPUT
CONTROL UNIT FOR OCCUPANCY SENSOR,
3.
FIRE ALARM
PANEL WIRING SHALL BE CONCEALED, BUT MAY BE EXPOSED WHERE NOT POSSIBLE.
ALL CONDUITS TO FIRE ALARM CONTROL PANEL SHALL BE RUN INTO THE SIDE OF THE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
J
GROUNDING TYPE, WITH PLUG.
RECEPTACLE, SINGLE, 2P-3W-50A-250V,
TS
1H
A. CONSTRUCTION / ALTERNATE
AS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
LEGEND, NOTES AND SCOPE OF WORKS
KIM, CK
E-01
RECEPTACLE, KOREAN DUPLEX, 2P-3W-20A-250V, GRD’G TYPE.
KKK
NEW ONES AS SHOWN IN DRAWINGS.
REPLACE DETERIORATED EXISTING WATT HOUR METER, GROUND ROD, WIRES AND CONDUITS FOR ELECTRICAL POWER CIRCUIT WITH
IN DRAWINGS.
REPLACE DETERIORATED EXISTING ELECTRICAL POWER AND CONTROL WIRING FOR NEW HVAC SYSTEM WITH NEW ONES AS SHOWN
ROOM AS SHOWN IN DRAWINGS.
EXHAUST FAN, RE-CIRCULATION PUMP, UNIT HEATER, AND NATURAL GAS DETECTION/ ALARM SYSTEM IN MECHANICAL ROOM AND ELECTRICAL
REPLACE NEW ELECTRICAL POWER AND CONTROL CIRCUIT INCLUDING MAGNETIC MOTOR STARTERS FOR DOMESTIC HOT WATER HEATER, WIRES, CONDUITS AND NECESSARY ACCESSORIES WITH NEW ONES AS SHOWN IN DRAWINGS.
REPLACE DETERIORATED EXISTING UNDERGROUND EXTERIOR TELEPHONE CABLES AND FIBER OPTIC CABLING SYSTEM INCLUDING
REPLACE EXISTING DETERIORATED ADDRESSABLE FIRE ALARM CONTROL PANEL, BATTERIES AND TRANSCEIVER AS SHOWN IN DRAWINGS.
6.
7.
8.
9.
SSS
SOSSOSSOS
PASSIVE INFRARED OR ULTRA SONIC, 120/ 277V
OCCUPANCY SENSOR SWITCH, CEILING MOUNTED,
PASSIVE INFRARED OR ULTRA SONIC, 120/ 277V
OCCUPANCY SENSOR SWITCH, WALL MOUNTED
ENCLOSED TYPE CIRCUIT BREAKER
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
VARIOUS WATT LED PANEL AND DRIVER.
LED FLAT LIGHTING FIXTURE, 120~277VAC,
120VAC, 16W LED LAMP.
LED LIGHTING FIXTURE, CEILING MOUNTED,
120VAC, 24W PANEL AND DRIVER WITH EMERGENCY UNIT.
LED LIGHTING FIXTURE, WALL MOUNTED,
NEW ONES AS SHOWN IN DRAWINGS.
HAND-OFF-AUTO SELECT SWITCH, PHOTOCELL SWITCH, OCCUPANCY SENSOR SWITCHES INCLUDING WIRES AND CONDUITS WITH
REPLACE DETERIORATED EXISTING INTERIOR LIGHTING FIXTURES, CANOPY LIGHTING FIXTURES, EXIT SIGNS, TOGGLE SWITCHES, CIRCUIT FOR FIRE SPRINKLER SYSTEM WITH NEW ONES AS SHOWN IN DRAWINGS.
BATTERY BOX, SURGE SUPPRESSION AND WIRING FOR FIRE ALARM SIGNAL CIRCUIT, BUILDING TRANSCEIVER AND NOTIFICATION APPLIANCE
REPLACE EXISTING DETERIORATED FIRE ALARM SYSTEM WITH NEW MANUAL PULL STATIONS, COMBO AUDIO/VISUAL SIGNAL SPEAKER, SYSTEM WITH NEW ONES AND REVISE PANEL BOARDS AS SHOWN IN DRAWINGS.
SELECT SWITCHES, SAFETY SWITCHES, JUNCTION BOXES, MAGNET MOTOR SWITCHES, LIGHTING CONTROLLER AND ASSOCIATED WIRING
REPLACE DETERIORATED EXISTING INTERIOR POWER SYSTEM INCLUDING CIRCUIT BREAKERS, RECEPTACLES, OUTLETS, HAND-OFF-AUTO
NEW ONES AND INSTALL NEW PANEL BOARD FOR COMMUNICATION ROOM AS SHOWN IN DRAWINGS.
OUTLETS, COPPER/FIBER OPTIC CABLES, CABLE TRAYS, COMMUNICATION RACK, CONDUITS AND PROTECTED ENTRANCE TERMINAL WITH
REPLACE EXISTING DETERIORATED COMMUNICATION SYSTEM INCLUDING TELEPHONE TERMINAL BOARDS, PATCH PANELS, TELEPHONE/LAN
10.
11.
CONTRACTOR SHALL REMOVE ALL LIGHTING CONTROL SYSTEM OF JOHNSON CONTROL.
SYSTEM INSTALLED BY JOHNSON CONTROL.
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL & REINSTALLATION AND ALL ASSOCIATED COSTS WITH EXISTING (OR NEW) DDC
ESPC SYSTEM
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-02
SCALE : 1 /100- E02
P-1
N O T T O S C A L E
- E02
D-1 EXTERIOR LTG. CONTROL DIAGRAM
SOS
SOS
SOS
SOS
SOS S
SS
S S
S
SOS
S
OSS
O S
S
SOS SOS
S
S
S
S
S
S
O S
S
SOS
S
S
S O
S
A-1
A-2,3
A-2
S
A-4
A-5
A-7
A-6
S
H.O.A
A-11
113 114
109 108
104 105
122 123
C
H A
P
H A S E
W
IR
E
/2
V O
L T
H Z
N
CKT11
CKT8
CKT10
CKT17
(AUTO-OFF-HAND),NEMA 1 ENCL.
NEW 3 POSITION SELECTOR SWITCH
1PH, 120V, 1KW (MAX.)
NEW PHOTOCELL,
CONTACTORS, SEE
INCL. SELECT SWITCH AND
LIGHTING CONTROL BOX
NEW PHOTOCELL AND
- E02
D-1
E X
IS
T
IN
G
P A
N E L B
O A
R D
"A
LIGHTING PLAN
EXTERIOR LTG. CONTROL DIAGRAM
LIGHTING PLAN AND
NEMA 1 ENCL
CONTACT : 1PH, 120V, 30A, 6POLE-1EA
(VOLTAGE CODE : V02)
COIL : 1PH, 120V, 20A-1EA
MECHNICALLY HELD TYPE
NEW SURFACE MTD LIGHTING CONTACTOR ’LC’,
N E
W
L
IG
H T
IN
C O
N T
A C
T O
R
’L
C
LIGHTING FIXTURES
LIGHTING FIXTURES AND BOLLARD
EXISTING HORIZONTAL FLOOD
LIGHTING FIXTURES
EXISTING PARKING-LOT
LIGHTING FIXTURES
EXISTING PARKING-LOT
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
LIGHTING FIXTURES
NEW BUILDING CANOPY S
(TYP. OF 22EA)
LIGHTING FIXTURE "NS-LED3" TYPE
FICTURE WITH NEW LED
REPLACE EXISTING CANOPY LIGHTING
ARMS ROOM DOOR (TYP. OF 1EA)
TYPE LED LIGHTING FIXTURE "NS-LED4" ABOVE
NEW WALL MOUNTED VANDAL RESISTANT
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-03
TYPE "XL1"
ELECTRICAL: 120 AND 277 VOLT WITH BACK-UP BATTERY OPERATING
SCALE : NONE
SHIELDING: FLAT SHEET ACRYLIC
LED STENCIL FACE EXIT SIGN
LAMP TYPE: LED
MOUNTING: UNIVERSAL
LETTERS: RED
NOM. DIMENSIONS 289 mm X 200 mm X 44 mm
REQUIRED
LETTERS WITH 19 mm (3/4") STROKE. DIRECTIONAL ARROWS AS
HARDWARE FINISH TO MATCH HOUSING FINISH. 152 mm (6") H
HOUSING: DIE-CAST ALUMINUM OR 20 GA. COLD ROLLED STEEL,
OTHER: MINIMUM BRIGHTNESS 20 CD/SQ METER ON FACE OF SIGN.
FEATURES
GENERAL DESCRIPTION
- E03
D-1
ONE BUTTON 120/277V AC, 1,000 SQ FT COVERAGE, 800W
MANUAL ADJUSTMENT TIME DELAY(20 SEC ~ 30 MIN)
PASSIVE INFRARED TECHNOLOGY, PHOTO CELL(WS1277W)
PASSIVE INFRARED WALL SWITCH
PASSIVE INFRARED CEILING SWITCH
SCALE : NONE- E03
S-1 LIGHTING FIXTURE SCHEDULE
CEILING RECESSED
LIGHTING FIXTURE SCHEDULE
ROOM NAME
NO.
ROOM
TYPE
LAMP STD.DET.NO. 40-06-04
TYPE WATTS
MOUNTING METHOD
(TOTAL)
Q T Y R E M A R K
OPTION: DIMMING CONTROL, EMERGENCY BATTERY PACK,
120~277VAC, COLOR TEMP. 4000K, CRI 80, LIFE TIME 50,000HRS,
RATED POWER 20W, EFFICIENCY 110 LPW MIN, UL APPROVED,
FRAME, BLACK PLATE, FINISH, 600mm W X 600mm L, RECESSED MOUNTED, WHITE POWDER COATED ALUMINUM
LED RECESSED TROFFER
LED RECESSED TROFFER
OPTION: DIMMING CONTROL, EMERGENCY BATTERY PACK,
120~277VAC, COLOR TEMP. 4000K, CRI 80, LIFE TIME 50,000HRS,
RATED POWER 20W, EFFICIENCY 110 LPW MIN, UL APPROVED,
FRAME, BLACK PLATE, FINISH, 300mm W X 1230mm L, RECESSED MOUNTED, WHITE POWDER COATED ALUMINUM
CEILING SURFACE
SECURE STORAGE LED NS-LED1 20
MAIN ENTRANCE LED NS-LED1 20 1101
EMERGENCY BALLAST1
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
COMM. STORAGE LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
LED NS-LED2 20
EMERGENCY BALLAST5
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
CO. CDR OFFICE LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
TRAINING ROOM LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
PLATOON OFFICE LED NS-LED1 20
EMERGENCY BALLAST3
CEILING RECESSED
CEILING RECESSEDLED NS-LED1 20 1116
LED NS-LED1 20
EMERGENCY BALLAST2
CEILING RECESSED
LED NS-LED1 20
EMERGENCY BALLAST1
CEILING RECESSED
CEILING RECESSEDLED 20 1119
EMERGENCY BALLAST1
CEILING RECESSED
EMERGENCY BALLAST1
CEILING RECESSED
CEILING RECESSEDNS-LED1 20 1122
CEILING RECESSED1123
LED 4 7
COMM. ROOM
NBC STORAGE
STORAGE
HALL WAY
MEN TOILET
WOMEN TOILET
MEN SHOWER
WOMEN SHOWER CEILING SURFACE
1SG OFFICE
CONFERENCE ROOM
XO OFFICE
STORAGE
ARMS ROOM
UNIT STORAGE
STORAGE
MECH. ROOM
AHU ROOM
STORAGE
ELECT. ROOM
EXIT SIGN
EMERGENCY BALLAST
EMERGENCY BALLAST
EMERGENCY BALLAST
EMERGENCY BALLASTFLUOR.
FLUOR.
FLUOR.
LED
XL1 WALL MOUNTED
2/ 25
2/ 25
2/ 25SF10
SF10
SF10
NS-LED1
NON STANDARD LIGHTING FIXTURE DETAILS
NON STANDARD LIGHTING FIXTURE DETAILS
LIGHTING FIXTURE SCHEDULE AND
EMERGENCY BALLAST
EMERGENCY BALLAST
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
TYPE "NS-LED1"
TYPE "NS-LED2"
LED NS-LED3 16 22 CEILING SURFACECANOPY
NS-LED4 24 1 EMERGENCY BALLASTWALL MOUNT
LED RECESSED TROFFER
TYPE "NS-LED4"
CEILING RECESSED
CEILING RECESSED
LED NS-LED1 20
LED NS-LED1 20
CO. LTD OR ABOVE / EQUAL.
SENSOR, UL LISTED, MODEL NO. CU120A, MANUFACTURER: HUBBLE
ELECTRICAL: 120 AC, 60HZ INPUT FOR ATD, ATU, AND ATP SERIES
CONTROL UNIT
CO. LTD OR ABOVE / EQUAL.
CEILING MOUNT, MODEL NO. ATP 1500C, MANUFACTURER: HUBBLE
PASSIVE INFRARED TECHNOLOGY, 1500 SQUARE FEET COVERAGE,
PASSIVE INFRARED OCCUPANCY SENSOR
OPTION: EMERGENCY BATTERY PACK,
LIFE TIME 50,000HRS,
UL APPROVED, 120~277VAC, COLOR TEMP. 4000K, CRI 80,
END CAPS, VANDAL RESISTANT, RATED POWER 24W,
WALL MOUNTED, STEEL HOUSING AND RIGID CONSTRUCTION
LED NS-LED3
LED NS-LED3
WHITE ACRYLIC DIFFUSER, STANDARD DIMMING
OUTDOOR TYPE. 1PH, 120V, 16W, 11"DIA, ELECTRICAL DRIVER,
CEILING MOUNTED LONG-LIFE LED LIGHTING FIXTURE,
LED FLUSH MOUNTED
TYPE "NS-LED3"
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-04
SCALE : 1 /100- E04
P-1
"A" "B" "C" "MDP"
B-1
B-1,2
B-1,2,3
B-4,5,6
B-4
B-4,5
B-7,8
B-7
B-7,8,9
B-10
B-11
B-11,12
B-13,14
B-13
B-15
"A" "B" "C" "MDP"
K
K
K
K
K
K
K
K
K
KK
B-17
B-19
B-18
S 3 S3
S
S
J J
S
C-3
C-4
C-5
C-6
C-7C-8
SCALE : 1 /100- E04
P-2ELECTRICAL POWER PLAN 1 ELECTRICAL POWER PLAN 2
ELECTRICAL POWER PLAN 1 AND 2
20A-250V (TYP. OF 10EA)
KOREAN TYPE RECEPTACLE, DUPLEX,
SEE DRAWING NO. M-2
(MECH. ITEM, TYP. OF 4EA)
ROOF EXHAUST FAN, 1 /4HP, 1PH-115V-60HZ
"KA"
REMOVE EXISTING PANELBOARD "KA"
"T"
"T"
M-12
AND
AND
AND
AND
ANDSEE DRAWING
NEW PANELBOARD "T"
- E18
S-3
- E18
S-1
- E17
S-2
- E17
S-1
- E15
S-1
- E20
S-3
- E20
S-1
- E19
S-2
- E19
S-1
- E19
S-3
AND
- E18
S-2
- E20
S-2
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
SEE DRAWING
REVISE PANELBOARD "MDP"
SEE DRAWING
REVISE LOAD CENTER "C"
SEE DRAWING
REVISE LOAD CENTER "B"
SEE DRAWING
REVISE LOAD CENTER "A"
SEE DRAWING
REVISE LOAD CENTER "M"
Storage
Arms RM
Platoon Office (4EA)
Training RMXO
CO. CDR
Conference RM
1SG
NBC Storage Storage Communication
Comm RM
Secure Storage
Unit Storage MECH
Storage Storage ELEC
AHU RM
Main Entrance
Storage
Toilet Men
Toilet Women
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-05
Tch
Tch
Tch
Tch
Tch
Tch
Tch Tch
Tch
Tch cT
J
J
J
J
J J
J
C-1
M-1
J J
J
J
J
J
J
J
C-2
J
"T"
J
C-12
C
C
C
C
C
C
C C
C
C
C
C
"A" "B" "C" "MDP"
T-1
"M""M"
M-2
SCALE : 1 /100- E05
P-1
SCALE : 1 /100- E02
P-1
J
J
"MMS-2"
"MMS-1"
HVAC EQUIPMENT CONTROL PLAN
HVAC EQUIPMENT POWER PLAN
AND CONTROL PLAN
HVAC EQUIPMENT POWER PLAN
SEE DRAWING NO. M-11
FOR HEAT PUMP UNIT (MECH. ITEM, TYP. OF 10EA)
TEMPERATURE CONTROLLER W/ SHUT OFF SW
SEE DRAWING NO. M-11
AIR CONDITIONING UNIT (MECH. ITEM)
THERMOSTAT FOR WALL MOUNTED TYPE
- INSTALL SAME AS OUTDOOR HEAT PUMP UNIT#1
(MECH. ITEM), SEE DRAWING NO. M-2
OUTDOOR HEAT PUMP UNIT#1, 3PH-208V-60HZ,
2-#10 AWG "THW" & 1-#12 AWG (G) IN 22 MM RMC
1PH-208V-60HZ, (MECH. ITEM, TYP. OF 1EA), SEE DRAWING NO. M-2
WALL MOUNTED TYPE AIR CONDITIONING UNIT,
2P-250V-30A, (TYP. OF 1EA)
SAFETY SWITCH, NEMA 3R, FUSIBLE TYPE,
- INSTALL SAME AS INDICATED DRAWING NO. E-06
(MECH. ITEM), SEE DRAWING NO. M-2
ELECTRIC UNIT HEATER AND WALL EXHAUST FAN
(MECH. ITEM, TYP. OF 3EA), SEE DRAWING NO. M-2
INDOOR HEAT PUMP UNIT, 1PH-208V-60HZ, 4-WAY,
(MECH. ITEM, TYP. OF 4EA), SEE DRAWING NO. M-2
ENERGY RECOVERY VENTILATOR, 1PH-208V-60HZ,
(MECH. ITEM, TYP. OF 1EA), SEE DRAWING NO. M-2
DEHUMIDIFIER, 1PH-115V-60HZ
(MECH. ITEM), SEE DRAWING NO. M-2
OUTDOOR HEAT PUMP UNIT#1, 3PH-208V-60HZ,
3P-250V-60A, (TYP. OF 2EA)
SAFETY SWITCH, NEMA 3R, FUSIBLE TYPE,
3-#6 AWG "THW" & 1-#10 AWG (G) IN 28 MM RMC
(MECH. ITEM, TYP. OF 7EA), SEE DRAWING NO. M-2
INDOOR HEAT PUMP UNIT, 1PH-208V-60HZ, 2-WAY,
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
C
C C
C
C
C
C
C
C
C C
C
C
C
C
(MECH. ITEM) SEE DRAWING NO. M-11
FOR ALL HEAT PUMP SYSTEM
CENTRAL CONTROLLER
ITEM, TYP. OF 4EA) SEE DRAWING NO. M-11
FOR ENERGY RECOVERY VENTILATOR (MECH.
VENTILATION CONTROLLER W/ SHUT-OFF SW
C-9 C-13
CcVCVC VC VC
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-06
SCALE : 1 /50- E06
P-1
"M"
J
VOLTAGE 208, NEMA 1 ENCL
SWITCH, "HAND-OFF-AUTO" SELECTOR SWITCH & PILOT LIGHT, COIL
2P-208VAC-60HZ-1HP-NEMA SIZE 0, "START-STOP" PUSH BUTTON
MAGNETIC MOTOR STARTER, W/MELTING ALLOY OVERLOAD RELAYS,
(1/4 HP, 115V, 1 PH, 60 HZ)
WALL EXHAUST FAN
"MMS-2"
"MMS-1" 5
QTYITEM NO. DESCRIPTION REMARK
MECH. RM MAGNETIC MOTOR STARTER SCHEDULE
(1/3 HP, 115V, 1 PH, 60 HZ)
DOMESTIC HOT WATER HEATER
(3.0KW, 1/ 100 HP, 208V, 1 PH, 60 HZ)
UNIT HEATER
(1/3 HP, 115V, 1 PH, 60 HZ, 1750 RPM)
DOMESTIC HOT WATER RE-CIRCULATION PUMP
J
J
M-3
J
M-4
M-6
"MMS-2"
"MMS-1"
"MMS-1"
M-7
J
M-5
"MMS-2"
J
M-10
SCALE : 1 /50- E06
P-2
"M"
J J
C C C
J
J
C
"MMS-2"
J
J cT cT cT cT
"MMS-1"
C
C
C
C
(MECH. ITEM, TYP. OF 2EA)
THERMOSTAT FOR UNIT HEATER
(MECH. ITEM, TYP. OF 2EA)
THERMOSTAT FOR EXHAUST FAN
TYP. OF 3EA) SEE DRAWING NO. M-2
FAN MOTOR, 1PH-115V-60HZ (MECH. ITEM,
ELECTRIC UNIT HEATER, 3KW WITH 1 /100HP
"MMS-1"
(MECH. ITEM), SEE DRAWING NO. M-14
THERMOSTATIC MIXING VALVE
(MECH. ITEM), SEE DRAWING NO. M-14
HOT WATER SENSOR
(MECH. ITEM), SEE DRAWING NO. M-2
HOT WATER HEATER, 1PH-120V-60HZ,
SEE DRAWING NO. M-2
1PH-120V-60HZ, 1 /3HP, (MECH. ITEM)
DOMESTIC HOT WATER RE-CIRCULATION PUMP
MECH. AND AHU RM CONTROL PLANMECH. AND AHU RM ELECTRICAL POWER PLAN
AND CONTROL PLAN
MECH. AND AHU RM ELECTRICAL POWER
EXISTING LOAD CENTER "M"
SEE DRAWING NO. M-2
(MECH. ITEM, TYP. OF 3EA)
WALL EXHAUST FAN, 1 /6HP, 1PH-115V-60HZ
(MECH. ITEM)
EXSTING GAS DETECTION SYSTEM
M-13
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
VOLTAGE 120, NEMA 1 ENCL
SWITCH, "HAND-OFF-AUTO" SELECTOR SWITCH & PILOT LIGHT, COIL
2P-115VAC-60HZ-1/3HP-NEMA SIZE 00, "START-STOP" PUSH BUTTON
MAGNETIC MOTOR STARTER, W/MELTING ALLOY OVERLOAD RELAYS,
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-07
SCALE : 1 /100- E02
P-1 COMMUNICATION PLAN
TTB
- E07
S-1
CR
T-L
T-L
T-L T-L
T-L
T-L
T-L T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
109 108
122 123
12-1
12-2
13-1 13-2 14-1
14-2
15-1
15-2
15-3
15-4 15-5 15-6
15-7
15-8
15-9
15-10
17-1
18-1
21-1
20-1
3-1
2-1
6-1
4-1
5-1
10-1
10-2
11-1
11-2
11-3
11-4
L
T-L
T-L
TELEPHONE OUTLET
BLANK WITH COVER
(TYPE ; RJ-45)
LAN (COMPUTER) SYSTEM OUTLET,
- E07
D-1
N O T T O S C A L E
COMMUNICATION OUTLET DETAIL
EXST NEW
LEGEND FOR COMMUNICATION
SINGLE GANG, LUG TYPE OUTLET
QUADPLEX OUTLET, TYPE ’B’
L
DOUBLE GANG, LUG TYPE OUTLET
L
LL
CR CR COMMUNICATION RACK
COMMUNICATION OUTLET DETAIL
COMMUNICATION PLAN AND
TTB TTB TELEPHONE TERMINAL BOARD
L
L
NEW CAT-6, 2W-4PAIR, #24AWG IN 27MM RMC
WITH COVER PLATE (TYP. OF 2EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW LUG TYPE DOUBLE MODULAR JACK
NEW CABLE TRAY 200MM X 100MM (TYPICAL)
WITH QUAD COVER PLATE (TYP. OF 28EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW DUAL MODULAR JACK
WITH COVER PLATE (TYP. OF 1EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW LUG TYPE SINGLE MODULAR JACK
- LOCATION SHALL BE NEAR BY CABLE TRAY
NEW ACCESS DOOR FOR MAINTENANCE
SEE
AND COMMUNICATION RACK
NEW TELEPHONE TERMINAL BOARD
EXTERIOR PULLBOX, 600MM W X 600MM X 150MM T
WITH A UNIQUE IDENTIFIER CODE. LABELING SHALL BE A MINIMUM OF 6MM HIGH.
ALL OUTLETS AND PATCH PANEL POSITIONS SHALL BE LABELED AS TO THEIR FUNCTION AND
1.
NOTES FOR COMMUNICATION SYSTEM
LUG TYPE OUTLETS SHALL BE INSTALLED ON THE APPROXIMATED 1200MM HEIGHT FROM FLOOR.
ALL CABLE TRAY ARE GRID PATTERN ED, COMPOSED OF MIN. 0.187" THK COLD ROLL STEEL.
POWER SUM EQUAL-LEVEL FAR-END CROSSTALK(PSELFEXT), RETURN LOSS, PROPAGATION DELAY AND DELAY SKEW
- WIRE MAP, LENGTH, INSERTION LOSS, NEAR-END CROSSTALK(NEXT) LOSS, POWER SUM NEAR-END CROSSTALK (ELFEXT), THE CONTRACTOR SHALL SUBMIT TEST REPORT TO COR INCLUDE BELOW.
7. THE RANGE OF TEST SHALL BE FROM MAIN DISTRIBUTION FRAME IN SIGNAL FACILITY TO NEW TELECOMMUNICATION ROOM.
2.
3.
4.
5.
6.
8. ALL COMMUNICATIONS WORK EFFORTS WILL BE IN ACCORDANCE WITH I3A STANDARD.
THE UL LISTED TWO HOLE LUG SHALL BE USED FOR ALL TERMINAL WORK OF TMGB.
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
PVC CONDUIT WITH 3WAY-MAXCELL INNER DUCT
AND 12 STRAND SINGLE-MODE FOC IN 104MM
NEW 1-25PAIR, #24AWG TELECOMMUNICATION CABLE
SHALL BE SHOWN IN THE SHOP DRAWING SUBMITTAL.
THE CONTRACTOR SHALL SUBMIT THE DETAILED SHOP DRAWINGS. THE WIRING AND FINAL DEVICE ADDRESS
THE WIRING PLAN AND DIAGRAM OF COMMUNICATION SYSTEM IS CONCEPTUAL FOR IGCE PURPOSE ONLY.
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-08
G
G
G
G
G
G
G
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
ROOM
COMMUNICATION
- E08
D-1
3-1
2-1
4-1
5-1
6-1
10-1
10-2
12-2
13-1
13-2
14-1
14-2
17-1
18-1
20-1
21-1
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
T-L
11-1
11-2
11-3
11-4
12-1
15-1
15-2
15-3
15-4
15-5
15-6
15-7
15-8
15-9
15-10
T
T-L
T-L
L
L
L
WITH QUAD COVER PLATE (TYP. OF 28EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW DUAL MODULAR JACK
WITH COVER PLATE (TYP. OF 2EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW LUG TYPE DOUBLE MODULAR JACK
WITH COVER PLATE (TYP. OF 1EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW LUG TYPE SINGLE MODULAR JACK
COMMUNICATION SYSTEM DIAGRAM
SCALE : NONE
OPTIC CABLE IN 103MM RMC
EXISTING 1-12STRAND SINGLE MODE FIBER
NEW 1-25PAIR, #24AWG TEL CABLE AND
FIBER OPTIC CABLE
EXISTING 1-12 STRAND SINGLE MODE
NEW 1-25PAIR, #24AWG TEL CABLE
3M LENTH MIN
SERVICE LOOP,
FIRE RATED PLYWOOD 5EA
1200MM W X 2400MM H X 20MM THK,
NEW TELEPHONE TERMINAL BOARD(TTB)
CALBE TRAY (TYPICAL)
NEW CABLE SUPPORT/
OR EQUIVALENT)
MANUFACTURE: CIRCA ENT. INC.
(MODEL NO. 21880ENA1/NSC-25,
TERMINAL BLOCK 110 TYPE
NEW 25PAIR PROTECTED ENTRANCE
1-#6 AWG "BC"
NEW GROUNDING WIRE,
"BC" IN 22 mm RMC.
NEW GROUNDING WIRE,1-#3/ 0 AWG
BAR IN MAIN PANEL "MDP"
CONNECT TO MAIN GROUND
(100mm(W) X 6.4mm(T) X 300mm(L)
GROUNDING BUSBAR (TMGB)
NEW TELECOMMUNICATION MAIN
NEW CABLE TRAY 200MM X 100MM (TYPICAL)
GROUNDING LUG (TYPICAL)
NEW UL LISTED TWO HOLE
TELEPHONE OUTLETS (TYP. OF 31EA)
CAT 6, 4PAIR, #24AWG FOR
LAN OUTLETS (TYP. OF 30EA)
CAT 6, 4PAIR, #24AWG FOR
2100MM H X 475MM W
FLOOR MOUNTED RACK,
PATCH PANEL W/6-PIN MOD CONNECTORS
NEW 2EA-24PORTS RACK MOUNTED, CAT 6
CAT 6 PATCH CORDS, 48EA
PORTS AS REQUIRED (GFM)
FIBER OPTIC SWITCH, NUMBER OF
FIBER OPTIC PATCH CORD, 1-SINGLE MODE
PRODUCED PIG TAIL
INCL. FUSION SPLICE FACTORY
12 PORTS, RACK MOUNTED TYPE,
NEW FIBER OPTIC DISTRIBUTION FRAME,
NEW CAT 6 PATCH CORDS, 48EA
VOICE PATCH PANEL, CAT-6
NEW 4EA-24PORTS RACK MOUNTED
NEW CAT 6 PATCH CORDS, 25EA
(TYP. OF 4EA)
110 TYPE TERMINAL BLOCK
NEW BACKBOARD MOUNTED
WITH DEDICATED CIRCUIT OF "LT-3" (TYP. OF 1EA)
MIN 6 RECEPTACLES, 2P-3W-125V-20A, GROUNDING TYPE
NEW RACK MOUNTED OUTLETS, SURGE SUPPRESSION TYPE
(480mm(W) X 13mm(T) X 50mm(L)
GROUNDING BUSBAR (TMGB)
NEW TELECOMMUNICATION MAIN
DEDICATED CIRCUIT OF "LT-3" (TYP. OF 1EA)
2P-3W-125V-20A, GROUNDING TYPE WITH
NEW SURGE SUPPRESSION TYPE DUPLEX RECEPTACLE,
TRAY
TO CABLE
COMMUNICATION SYSTEM DIAGRAM
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
IN COMM. RM (TYPICAL)
PANEL ON COMMUNICATION RACK
WIRE TO CONNECTED TO PATCH
NEW CAT-6, 2W-4PAIR, #24AWG IN 27MM RMC
IN COMM. RM (TYPICAL)
PANEL ON COMMUNICATION RACK
WIRE TO BE CONNECTED TO PATCH
NEW CAT-6, 1W-4PAIR, #24AWG IN 27MM RMC
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-09
CABLE (SPLICE POINT: CAX21 376-400)
SPLICE NEW 1-25PAIR #24AWG COPPER OSP
3WAY: SPARE WITH PULL WIRE
1WAY: 1-25PAIR #24AWG COPPER OSP CABLE
FROM MH 14-2A TO MH 14-1A
NEW 4WAY OF 103mm PVC CONC. ENCASED DUCT
CABLE IN EXISTING EMPTY DUCT
PULL NEW 1-25PAIR #24AWG COPPER OSP
COMMUNICATION SITE PLAN 1
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
S-396
S-
S-303
T
T
T-311
S
S-284
S
T-
T
S
S-
T-301
S
S 7 S-909
S-388
T-
S
T-127
S-119
S
S-100
S
S-305
P-1
SCALE: 1 / 1,000
MH20-2B
MH14
GRAPHIC SCALE
0 5 10 15 20 25M
HH20-1-3C
MH20-1-1B
MH20-1-3A
B
B
B B
MH20-1-1A
MH20-1
MH20
B
MH19
PB
MH18
B
B
B
B
B
MH20-1-2A
MH20-3B
MH14-2A
MH20-2
MH20-2A
48C
FO
C
S
M
HH14-4A
HH14-3A
B
B
MH14-1A
B
B
MH14-1
B
B
B
MH13
B
MH12
MH12-1
MH12-1A
B
MH12-1-1
MH12-2A
S-940 Tennis Court
S-294 Court Tennis
S-296 Court Tennis
S-165 Volleyball Court
S-980
STORY FIELD
LUTHER H.
T-646
S-671
S-672
S-673
S-674
S -644
T-780
T-508
S-86
S -7
S -7
S -7
T -6
T -5
T -7
T -5
S-961
T-533
T -5
S-714
S -8
T-377
T-584
T -3
T-3
S-531
T-417
T-863
T-765
T-368
T-507
T-772
S-967
T-924
T-575
T-696S-603
T-928
T-691
S-102
T-521
T-558
T-989
T-342
T-681
T-343
S-965
T-116
T-504
T-315
T-385
T-617
T-661
T-693
T-766
T-764
T-768
T-769
T-271
T-763
T-160
T-299
T-414
T-413
T-104
S-153
T-120
S-954
S-994
T-653
CEMETERY
S-860 Substation Electrical
S-360 Substation Electrical
S-576 Substation Electrical
S-133 bridge Foot
T-522
Footbridge
S-990 Footbridge
T-849 Footbridge
T-986 Footbridge
GATE 2
GATE 1
GATE 4
GATE 3
Gate Access
Railroad
Gate Access Farmer
Gate Access Farmer
S-118 Electronic Sign
S-952 Electronic Sign
S-781
Flag Pole
S-390
DEAD MEMORIAL
KOREAN WAR
S-741 Land Farm
T re a tm e n t
B e d
T re a tm e n t
B e d
Pond Holding
S-730
RANGE
QUALIFICATION
ZERO AND
25M RIFLE S-725
TESTING POND
BRIDGING BOAT
AMPITHEATRE
CAC
T-729 Storage Yard
Container
S-847
S-865 Bridge
Railroad
S-300 Road Bridge
S-860 Road Bridge
S-900 Road Bridge
S-500 Road Bridge
S-861 Road Bridge
A R
K A
N S
A S
N E
B R
A S
K A A
V E
N U
E
N E
W Y
O R
K A
V E
N U
E
A R
K A
N S
A S A
V E
N U
E
O H
IO
A
V E
N U
E
G E
O R
G
IA
A
V E
N U
E
T E
X A
S A
V E
N U
E
M O
N T A N
A A
V E N
U E
AVENUE
ILLINOIS AVENUE
A R
IZ
O N
A A
V E
N U
E
TENNESSEE AVENUE
N E
B R
A S
K A A
V E
N U
E
A M
E R
IC
A N A
V E N
U E
A R
K A
N S
A S A
V E
N U
E
PENN AVENUE
M
IS
S
IS
S
IP
P I
A V
E N
U E
A V
E N
U E
OHIO AVENUE
A M
E R
IC
A N A
V E N
U E
KENTUCKY AVENUE
G E
O R
G
IA
A
V E
N U
E
FLORIDA AVENUE
MISSISSIPPI
NEVADA
N E
W
N E
B R
A S
K A A
V E
N U
E
A M
E R
IC
A N A
V E N
U E
NEW YORK AVENUE
GEORGIA AVENUE
N E
B R
A S
K A A
V E
N U
E
OREGON
A V E N
U E
A V E N
U E
A V E N
U E
Y O
R K
PENN AVENUE
T-534
T-677
T-659
T-311
T-386
T-700
T-826
T-619
T-376
S-114
T-519
T-625
S-983
S-984
S-387
T-509B
T-509-2
T-578 Vehicle Scales
T-509-1
S-284
T-115
S-401
S-269
Bus Stop 10
S-383 Bus Stop 9
S-933 Bus Stop 6
S-621 Vehicle Scales
S-701
T-369
S-378
T-89
T-513
S-669 Station
Hunter Brake
S-328
S-329
T-509C
T-503 Bus Stop 1
S-622
T-624
S-639
T-416
T-827
S-350
T-415
T-979
S-667
S-705
T-926
T-577
T-720 Bus Stop 5
T-412
T-509D
T-509A
DUMP POINT
INDUSTRIAL WASTE
RECYCLING CENTER AND S-839
S-835
S-665
S-840
S-837
S-836
S-605
S-606
S-607
S-608
S-985
S-955
S-709
S-510
S-326
S-530
S-818
S-817
S-135
S-620
S-151
S-821
S-405
T-645
S-846
T -5
S-327
S -5
S-970
S-117
S-601
S-684
S-138
S-388
S-139
S-668
S-831
S-825
S-917
S-915
S -9
S-612
S -9
S-256
S-111
S-233
S-563
S-110
S-711
T-
S-231
S-396
S-230
S-100 S-235
S-375
S -9
S-136
S-403
T-565
S-253
S-250
S-977
S-676
S-254
S-573
S-946
S-998
S-203
S-841
S-123
S-938
S-657
S-914
T-516
S-341
S-911
S-113
T-520
S-913
S-141 S-143
S-142
S-264
S-731
S-101
S -309
S -2
S -7
S -9
T -9
T -9
S -9
S -9
S -2
S -9
S -6
S-675
S-320
S -8
S -8
S -9
T -5
T -9
S-9
S -9
S -3
T-318
S -4
S -6
S -3
S -8
S-9
S -6
S -8
S -8
T-126
S-121
T-125
T-127
T-207
S -1
T-236
S -9
S -6
T-206
S -3
S -9
T -3
S -3
S-154
S -9
S -8
S-974
S-321
S-
S-910S -4
S-340
S -6
S -7
S-349
S-301
S -611
T -3
S -6
S -7
S -7
S-140
S -6
S-718
S -7
S-137
S -6
S-842
S-351
S-512
S-205
S -5
S-336
S-239
S -9
S -3
S-267
S-509
T-359
S -3
S-532
S -9
S-655
S-208
T -7
S-702
S-163
S-304
T-515
S-733
S-732
S-642
S-627
T-384
S -3
T -5
T -3
S-312
S-666
S-420
S-973
T -3
T-580
S-679
T-996
S-925
T-997
S-931
T-631
T -2
S-131
S-919
T -3
T-521
S-395
S-397
S-918
S-944
T-195
T-196
T-198
T-197
T-194
T-199
S-119
S-739
S-3
S-647
T-261
S-164
S-626
S-58
T-130
S-717
S-402
T-572
T-189
T-406
T-193
T-958
S-88
S-348
T-581
S-265
S-640
S-953
S-411
S-664
S-654
S-344
S-511
S-982
S-968
S-929
T-155
S-972
T-582
S-771
S-95
T-409
S-948
S-916
S-947
S-957
T-192
S-956
S-719
T-762
S-770
S-162
S-161
T-317 Tower Cooling
T-923
S-93
S-922
T-814
T-812
T-569
T-635
S-995
T-810
T-280
T-811
T-633
T-103
T-813
T-637
T-636
S-741
TRAINING
CONFINED SPACE
BURN BUILDING AND
T-724
RESCUE
FIRE FIGHTING
S-845 Washrack
S-693 Washrack
S-404 Washrack
S-976 Washrack
S-939 Washrack
S-987 Washrack
S-316 Washrack
S-927 Washrack
T-6
S-703
PLANT
TREATMENT
SEWAGE
S-820
S-87
S-150
S-144
PLANT
TREATMENT
WATER
WETLAND
CAMP CARROLL
S-978 Substation Electrical
S-870
CLINIC
HEALTH/DENTAL
S
DFAC
S T O
R A G E
O R
G A N
IZ
A T
IO
N A L
MH20-1-1-1A
MH12-2-2-2A
E09
COMMUNICATION SITE PLAN 1
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-10
CABLE IN EXISTING EMPTY DUCT
PULL NEW 1-25PAIR #24AWG COPPER OSP
COMMUNICATION SITE PLAN 2
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
S-
S-974
S
S
S
S-
S
S
T-
A
S-
S
S-
S-940 Tennis Court
S-294 Court Tennis
S-296 Court Tennis
S-165 Volleyball Court
S-980
STORY FIELD
LUTHER H.
T-646
S-671
S-672
S-673
S-674
S -644
T-780
T-508
S-86
S -7
S -7
S -7
T -6
T -5
T -7
T -5
S-961
T-533
T -5
S-714
S -8
T-377
T-584
T -3
T-3
S-531
T-417
T-863
T-765
T-368
T-507
T-772
S-967
T-924
T-575
T-696S-603
T-928
T-691
S-102
T-521
T-558
T-989
T-342
T-681
T-343
S-965
T-116
T-504
T-315
T-385
T-617
T-661
T-693
T-766
T-764
T-768
T-769
T-271
T-763
T-160
T-299
T-414
T-413
T-104
S-153
T-120
S-954
S-994
T-653
CEMETERY
S-860 Substation Electrical
S-360 Substation Electrical
S-576 Substation Electrical
S-133 bridge Foot
T-522
Footbridge
S-990 Footbridge
T-849 Footbridge
T-986 Footbridge
GATE 2
GATE 1
GATE 4
GATE 3
Gate Access
Railroad
Gate Access Farmer
Gate Access Farmer
S-118 Electronic Sign
S-952 Electronic Sign
S-781
Flag Pole
S-390
DEAD MEMORIAL
KOREAN WAR
S-741 Land Farm
T re a tm e n t
B e d
T re a tm e n t
B e d
Pond Holding
S-730
RANGE
QUALIFICATION
ZERO AND
25M RIFLE S-725
TESTING POND
BRIDGING BOAT
AMPITHEATRE
CAC
T-729 Storage Yard
Container
S-847
S-865 Bridge
Railroad
S-300 Road Bridge
S-860 Road Bridge
S-900 Road Bridge
S-500 Road Bridge
S-861 Road Bridge
A R
K A
N S
A S
N E
B R
A S
K A A
V E
N U
E
N E
W Y
O R
K A
V E
N U
E
A R
K A
N S
A S A
V E
N U
E
O H
IO
A
V E
N U
E
G E
O R
G
IA
A
V E
N U
E
T E
X A
S A
V E
N U
E
M O
N T A N
A A
V E N
U E
AVENUE
ILLINOIS AVENUE
A R
IZ
O N
A A
V E
N U
E
TENNESSEE AVENUE
N E
B R
A S
K A A
V E
N U
E
A M
E R
IC
A N A
V E N
U E
A R
K A
N S
A S A
V E
N U
E
PENN AVENUE
M
IS
S
IS
S
IP
P I
A V
E N
U E
A V
E N
U E
OHIO AVENUE
A M
E R
IC
A N A
V E N
U E
KENTUCKY AVENUE
G E
O R
G
IA
A
V E
N U
E
FLORIDA AVENUE
MISSISSIPPI
NEVADA
N E
W
N E
B R
A S
K A A
V E
N U
E
A M
E R
IC
A N A
V E N
U E
NEW YORK AVENUE
GEORGIA AVENUE
N E
B R
A S
K A A
V E
N U
E
OREGON
A V E N
U E
A V E N
U E
A V E N
U E
Y O
R K
PENN AVENUE
T-534
T-677
T-659
T-311
T-386
T-700
T-826
T-619
T-376
S-114
T-519
T-625
S-983
S-984
S-387
T-509B
T-509-2
T-578 Vehicle Scales
T-509-1
S-284
T-115
S-401
S-269
Bus Stop 10
S-383 Bus Stop 9
S-933 Bus Stop 6
S-621 Vehicle Scales
S-701
T-369
S-378
T-89
T-513
S-669 Station
Hunter Brake
S-328
S-329
T-509C
T-503 Bus Stop 1
S-622
T-624
S-639
T-416
T-827
S-350
T-415
T-979
S-667
S-705
T-926
T-577
T-720 Bus Stop 5
T-412
T-509D
T-509A
DUMP POINT
INDUSTRIAL WASTE
RECYCLING CENTER AND S-839
S-835
S-665
S-840
S-837
S-836
S-605
S-606
S-607
S-608
S-985
S-955
S-709
S-510
S-326
S-530
S-818
S-817
S-135
S-620
S-151
S-821
S-405
T-645
S-846
T -5
S-327
S -5
S-970
S-117
S-601
S-684
S-138
S-388
S-139
S-668
S-831
S-825
S-917
S-915
S -9
S-612
S -9
S-256
S-111
S-233
S-563
S-110
S-711
T-
S-231
S-396
S-230
S-100 S-235
S-375
S -9
S-136
S-403
T-565
S-253
S-250
S-977
S-676
S-254
S-573
S-946
S-998
S-203
S-841
S-123
S-938
S-657
S-914
T-516
S-341
S-911
S-113
T-520
S-913
S-141 S-143
S-142
S-264
S-731
S-101
S -309
S -2
S -7
S -9
T -9
T -9
S -9
S -9
S -2
S -9
S -6
S-675
S-320
S -8
S -8
S -9
T -5
T -9
S-9
S -9
S -3
T-318
S -4
S -6
S -3
S -8
S-9
S -6
S -8
S -8
T-126
S-121
T-125
T-127
T-207
S -1
T-236
S -9
S -6
T-206
S -3
S -9
T -3
S -3
S-154
S -9
S -8
S-974
S-321
S-
S-910S -4
S-340
S -6
S -7
S-349
S-301
S -611
T -3
S -6
S -7
S -7
S-140
S -6
S-718
S -7
S-137
S -6
S-842
S-351
S-512
S-205
S -5
S-336
S-239
S -9
S -3
S-267
S-509
T-359
S -3
S-532
S -9
S-655
S-208
T -7
S-702
S-163
S-304
T-515
S-733
S-732
S-642
S-627
T-384
S -3
T -5
T -3
S-312
S-666
S-420
S-973
T -3
T-580
S-679
T-996
S-925
T-997
S-931
T-631
T -2
S-131
S-919
T -3
T-521
S-395
S-397
S-918
S-944
T-195
T-196
T-198
T-197
T-194
T-199
S-119
S-739
S-3
S-647
T-261
S-164
S-626
S-58
T-130
S-717
S-402
T-572
T-189
T-406
T-193
T-958
S-88
S-348
T-581
S-265
S-640
S-953
S-411
S-664
S-654
S-344
S-511
S-982
S-968
S-929
T-155
S-972
T-582
S-771
S-95
T-409
S-948
S-916
S-947
S-957
T-192
S-956
S-719
T-762
S-770
S-162
S-161
T-317 Tower Cooling
T-923
S-93
S-922
T-814
T-812
T-569
T-635
S-995
T-810
T-280
T-811
T-633
T-103
T-813
T-637
T-636
S-741
TRAINING
CONFINED SPACE
BURN BUILDING AND
T-724
RESCUE
FIRE FIGHTING
S-845 Washrack
S-693 Washrack
S-404 Washrack
S-976 Washrack
S-939 Washrack
S-987 Washrack
S-316 Washrack
S-927 Washrack
T-6
S-703
PLANT
TREATMENT
SEWAGE
S-820
S-87
S-150
S-144
PLANT
TREATMENT
WATER
WETLAND
CAMP CARROLL
S-978 Substation Electrical
S-870
CLINIC
HEALTH/DENTAL
S
DFAC
1026-1050
MH14-1-5-2
MH14-1-5
MH14-1-5-1
PB
PB
B
HH14-2C-1
B
B
B
MH14-1-4
MH14-1-3
B
B
MH14-1-2
MH14-3C
B
B
MH14-1-5-3
B
B
HH14-1-5-4
MH14-4C
MH14-2
MH14-3
MH14-4
B
B
S T O
R A G E
O R
G A N
IZ
A T
IO
N A L
GRAPHIC SCALE
0 5 10 15 20 25M
P-1
SCALE: 1 / 1,000
E10
COMMUNICATION SITE PLAN 2
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-11
COMMUNICATION CLOSET AND RELOCATE TO NEW COMMUNICATION ROOM
PULL OUT EXISTING 12STRAND FIBER OPTIC CABLE FROM EXISTING
NEW 3EA-104MM RMC TO NEW PULL BOX.
CUT EXISTING 3EA-104MM RMC NEAR BUILDING AND CONNECT WITH
CABLE TO NEW COMMUNICATION ROOM
AND EXISTING 1-12 STRAND FIBER OPTIC
NEW 1-25PAIR #24AWG COPPER OSP CABLE
CABLE IN EXISTING EMPTY DUCT
PULL NEW 1-25PAIR #24AWG COPPER OSP
COMMUNICATION SITE PLAN 3
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
S
GUARD
TOWER
T
S-983
S-982
FOOTBALL FIELD
S-980
S
T-
S-998
S-940 Tennis Court
S-294 Court Tennis
S-296 Court Tennis
S-165 Volleyball Court
S-980
STORY FIELD
LUTHER H.
T-646
S-671
S-672
S-673
S-674
S -644
T-780
T-508
S-86
S -7
S -7
S -7
T -6
T -5
T -7
T -5
S-961
T-533
T -5
S-714
S -8
T-377
T-584
T -3
T-3
S-531
T-417
T-863
T-765
T-368
T-507
T-772
S-967
T-924
T-575
T-696S-603
T-928
T-691
S-102
T-521
T-558
T-989
T-342
T-681
T-343
S-965
T-116
T-504
T-315
T-385
T-617
T-661
T-693
T-766
T-764
T-768
T-769
T-271
T-763
T-160
T-299
T-414
T-413
T-104
S-153
T-120
S-954
S-994
T-653
CEMETERY
S-860 Substation Electrical
S-360 Substation Electrical
S-576 Substation Electrical
S-133 bridge Foot
T-522
Footbridge
S-990 Footbridge
T-849 Footbridge
T-986 Footbridge
GATE 2
GATE 1
GATE 4
GATE 3
Gate Access
Railroad
Gate Access Farmer
Gate Access Farmer
S-118 Electronic Sign
S-952 Electronic Sign
S-781
Flag Pole
S-390
DEAD MEMORIAL
KOREAN WAR
S-741 Land Farm
T re a tm e n t
B e d
T re a tm e n t
B e d
Pond Holding
S-730
RANGE
QUALIFICATION
ZERO AND
25M RIFLE S-725
TESTING POND
BRIDGING BOAT
AMPITHEATRE
CAC
T-729 Storage Yard
Container
S-847
S-865 Bridge
Railroad
S-300 Road Bridge
S-860 Road Bridge
S-900 Road Bridge
S-500 Road Bridge
S-861 Road Bridge
A R
K A
N S
A S
N E
B R
A S
K A A
V E
N U
E
N E
W Y
O R
K A
V E
N U
E
A R
K A
N S
A S A
V E
N U
E
O H
IO
A
V E
N U
E
G E
O R
G
IA
A
V E
N U
E
T E
X A
S A
V E
N U
E
M O
N T A N
A A
V E N
U E
AVENUE
ILLINOIS AVENUE
A R
IZ
O N
A A
V E
N U
E
TENNESSEE AVENUE
N E
B R
A S
K A A
V E
N U
E
A M
E R
IC
A N A
V E N
U E
A R
K A
N S
A S A
V E
N U
E
PENN AVENUE
M
IS
S
IS
S
IP
P I
A V
E N
U E
A V
E N
U E
OHIO AVENUE
A M
E R
IC
A N A
V E N
U E
KENTUCKY AVENUE
G E
O R
G
IA
A
V E
N U
E
FLORIDA AVENUE
MISSISSIPPI
NEVADA
N E
W
N E
B R
A S
K A A
V E
N U
E
A M
E R
IC
A N A
V E N
U E
NEW YORK AVENUE
GEORGIA AVENUE
N E
B R
A S
K A A
V E
N U
E
OREGON
A V E N
U E
A V E N
U E
A V E N
U E
Y O
R K
PENN AVENUE
T-534
T-677
T-659
T-311
T-386
T-700
T-826
T-619
T-376
S-114
T-519
T-625
S-983
S-984
S-387
T-509B
T-509-2
T-578 Vehicle Scales
T-509-1
S-284
T-115
S-401
S-269
Bus Stop 10
S-383 Bus Stop 9
S-933 Bus Stop 6
S-621 Vehicle Scales
S-701
T-369
S-378
T-89
T-513
S-669 Station
Hunter Brake
S-328
S-329
T-509C
T-503 Bus Stop 1
S-622
T-624
S-639
T-416
T-827
S-350
T-415
T-979
S-667
S-705
T-926
T-577
T-720 Bus Stop 5
T-412
T-509D
T-509A
DUMP POINT
INDUSTRIAL WASTE
RECYCLING CENTER AND S-839
S-835
S-665
S-840
S-837
S-836
S-605
S-606
S-607
S-608
S-985
S-955
S-709
S-510
S-326
S-530
S-818
S-817
S-135
S-620
S-151
S-821
S-405
T-645
S-846
T -5
S-327
S -5
S-970
S-117
S-601
S-684
S-138
S-388
S-139
S-668
S-831
S-825
S-917
S-915
S -9
S-612
S -9
S-256
S-111
S-233
S-563
S-110
S-711
T-
S-231
S-396
S-230
S-100 S-235
S-375
S -9
S-136
S-403
T-565
S-253
S-250
S-977
S-676
S-254
S-573
S-946
S-998
S-203
S-841
S-123
S-938
S-657
S-914
T-516
S-341
S-911
S-113
T-520
S-913
S-141 S-143
S-142
S-264
S-731
S-101
S -309
S -2
S -7
S -9
T -9
T -9
S -9
S -9
S -2
S -9
S -6
S-675
S-320
S -8
S -8
S -9
T -5
T -9
S-9
S -9
S -3
T-318
S -4
S -6
S -3
S -8
S-9
S -6
S -8
S -8
T-126
S-121
T-125
T-127
T-207
S -1
T-236
S -9
S -6
T-206
S -3
S -9
T -3
S -3
S-154
S -9
S -8
S-974
S-321
S-
S-910S -4
S-340
S -6
S -7
S-349
S-301
S -611
T -3
S -6
S -7
S -7
S-140
S -6
S-718
S -7
S-137
S -6
S-842
S-351
S-512
S-205
S -5
S-336
S-239
S -9
S -3
S-267
S-509
T-359
S -3
S-532
S -9
S-655
S-208
T -7
S-702
S-163
S-304
T-515
S-733
S-732
S-642
S-627
T-384
S -3
T -5
T -3
S-312
S-666
S-420
S-973
T -3
T-580
S-679
T-996
S-925
T-997
S-931
T-631
T -2
S-131
S-919
T -3
T-521
S-395
S-397
S-918
S-944
T-195
T-196
T-198
T-197
T-194
T-199
S-119
S-739
S-3
S-647
T-261
S-164
S-626
S-58
T-130
S-717
S-402
T-572
T-189
T-406
T-193
T-958
S-88
S-348
T-581
S-265
S-640
S-953
S-411
S-664
S-654
S-344
S-511
S-982
S-968
S-929
T-155
S-972
T-582
S-771
S-95
T-409
S-948
S-916
S-947
S-957
T-192
S-956
S-719
T-762
S-770
S-162
S-161
T-317 Tower Cooling
T-923
S-93
S-922
T-814
T-812
T-569
T-635
S-995
T-810
T-280
T-811
T-633
T-103
T-813
T-637
T-636
S-741
TRAINING
CONFINED SPACE
BURN BUILDING AND
T-724
RESCUE
FIRE FIGHTING
S-845 Washrack
S-693 Washrack
S-404 Washrack
S-976 Washrack
S-939 Washrack
S-987 Washrack
S-316 Washrack
S-927 Washrack
T-6
S-703
PLANT
TREATMENT
SEWAGE
S-820
S-87
S-150
S-144
PLANT
TREATMENT
WATER
WETLAND
CAMP CARROLL
S-978 Substation Electrical
S-870
CLINIC
HEALTH/DENTAL
S
DFAC
MH14-1-9
P E
D
1-
HH14-1-9A
MH14-1-8
MH14-1-7
MH14-1-6
B
B
-20
P6C
A
S T O
R A G E
O R
G A N
IZ
A T
IO
N A L
GRAPHIC SCALE
0 5 10 15 20 25M
MH14-1-6A
P-1
SCALE: 1 / 1,000
E11
COMMUNICATION SITE PLAN 3
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-12
SCALE : 1 /100- E12
P-1
F
F
F
F
F
FF
F
F
S/S BTXF/A
M
M
TS
M
TS
M
TS FS
M M
TS
M
F F
F F
F
G
F
F F
F
F
N
N
N
N
N
S D
N
N
N
N
N
N N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NOTIFICATION APPLIANCE CIRCUIT
MANUAL PULL STATIONS
NEW KEY OPERATING TYPE ADDRESSABLE
MONITOR MODULE
ADDRESSABLE
(MECH. ITEM)
TEMPER SWITCH
(MECH. ITEM)
FLOW SWITCH
SYSTEM BOX
GAS DETECTION
FIRE ALARM SIGNALING LINE CIRCUIT
FIRE ALARM PLAN
C
DF
F
CO DETECTORS
NEW ADDRESSABLE
F-1
F-2
F-3
F-4
F-5 F-6
F-7
F-8
F-9
F-10
F-11
F-12
F-13
F-14
F-15
F-16
F-17
F-18 N
N
F F
F
F F
F
F
F
F
F
F F
F
F
F
FF
F
F
F
F
F
F
F
F
F
WITH ANTENNA SET, SEE
NEW BUILDING TRANSMITTER ’BTX’
FIRE ALARM PLAN
INSTALLED IN A MANNER THAT PROVIDES VISUALITY AND ACCESS FOR TESTING AND PERIODIC MAINTENANCE.
ALL FIRE ALARM INITIATING DEVICE SUCH AS SMOKE DETECTOR AND MANUAL PULL STATIONS SHALL BE
SHALL BE CONCEALED, BUT MAY BE EXPOSED WHERE NOT POSSIBLE.
ALL CONDUITS TO FIRE ALARM CONTROL PANEL SHALL BE RUN INTO THE SIDE OF THE PANEL WIRING
TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFING ALL EXISTING CONDITION AND DIMENSIONS PRIOR
MATERIAL.
TO VERIFY COMPLIANCE WITH STANDARDS. CONTACT FIRE PREVENTION OFFICE TO COORDINATE INSPECTION OF
ALL DEVICES AND EQUIPMENT MUST BE INSPECTED BY THE FIRE PREVENTION OFFICE PRIOR TO INSTALLATION
NOTES FOR FIRE ALARM SYSTEM
3.
SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND
SOME DETAILS SHOWN ON THIS DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL
9.
STANDARD.
AND MUST PROVIDE A LETTER STATING THAT THE SYSTEM IS INSTALLED IAW NICET STANDARDS AND NFPA
NICET CERTIFIED PERSON MUST BE ON SITE INSTALLING OR SUPERVISING INSTALLATION OF THE SYSTEM
MINIMUM NICET LEVEL III CERTIFICATION IS REQUIRED FOR ALL FIRE ALARM SYSTEM INSTALLATION.
2.
4.
7.
8.
6.
5.
OF 1’-6" AND ANY AIR SUPPLY DIFFUSER OR RETURN AIR OPENING A MINIMUM DISTANCE OF 3’.
FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING FIXTURE A MINIMUM DISTANCE
FOR FIRE ALARM SYSTEM SHOULD BE LOCATED IN ACCORDANCE WITH NFPA 72.
FIRE ALARM DEVICES INCLUDING INITIATING DEVICES, NOTIFICATION DEVICES AND ALL OTHER EQUIPMENT
OF MANUFACTOURE
IN RIGID METAL CONDUIT AND NUMBER AND SPECIFY OF WIRE/CABLE IS FOLLOWED AS DESIGNATION
FIRE ALARM CIRCUIT SHALL BE DOUBLE LOOP SYSTEM IN A SEPARATE CONDUIT AND ANY CIRCUIT
1.
THE WIRING AND FINAL DEVICE ADDRESS SHALL BE SHOWN IN THE SHOP DRAWING SUBMITTAL.
TECHNICAL REVIEW BRANCH AND FIRE PREVENTION OFFICE FOR APPROVAL PRIOR TO CONSTRUCTION.
THE CONTRACTOR SHALL SUBMIT THE DETAILED SHOP DRAWINGS AND DESIGN ANALYSIS TO THE
MEET WITH APPLICABLE CODES AND REGULATION TO COMPLETE SUBJECT PROJECT CONSTRUCTION.
COST CAUSE FROM NOT SHOWN OR/AND INDICATED IN THE CONCEPTURAL DRAWINGS TO
FOR IGCE PURPOSE ONLY. THE CONTRACTOR IS RESPONDSIBLE FOR ALL OTHER ADDITIONAL
THE WIRING PLAN AND DIAGRAM OF FIRE ALARM SYSTEM SHOWN ON DRAWINGS ARE CONCEPTUAL
- E13
S-2
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
(TYPICAL)
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
POWER CONNECT TO LOAD CENTER "A" CKT NO.12 (A-12)
NEMA 1 ENCL
DIGITAL VOICE PANEL W/AMPLIFIER & MICROPHONE
MODULE, BATTERY,BATTERY CHARGER, AND
PROGRAMMABLE MODULE & RELAYS POWER
ADDRESSABLB POINT MODULES AS REQUIRED,
NOTIFICATION CONTROL PANEL 24VDC BUILT-IN
NEW COMBINED ADDRESSABLE FIRE ALARM/ MASS
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-13
- E13
S-2 FIRE ALARM SINGLE LINE DIAGRAM
N O T T O S C A L E
FIRE ALARM SINGLE LINE DIAGRAM
TEMPER SWITCH (MECH. ITEM)
PULL STATIONS
ADDRESSABLE MANUAL
NEW KEY OPERATING TYPE
ADDRESSABLE MONITOR MODULE
SIGNALING LINE CIRCUIT
ON BLDG 153
COAXAL CABLE AND NEMA 3R ENCL
NEW LIGHTING ARRESTER KIT WITH
S/S
BATTERY F/A BTX
M
TS
M
FS
MM
TS
M
TS
M
TS
F-12
F
F-16
F
F-1F-2F-3
F F F
D C
D
SF
F-4
F F
F-5
F F
F-6
F FFFFF
F-7F-8F-9F-10
F-11
F F
F-13
F F
F-15
F
F-14
FM F
F-17
F F
F-18
F F
N
SMOKE DETECTOR
NEW ADDRESSABLE
1-#6 AWG(G) IN 21 mmC
IN 21 mmC
ANTENNA COAXIAL CABLE
MOUNTING BRACKET
OMNI-DIRECTION TYPE WITH
NEW FIRE ALARM ANTENNA
FN N FFNFNFNFNFNFNFNFNF
FN N FFNFNFNFNFNFNFNFNF
FFFF N N N
N
N
F
FLOW SWITCH (MECH. ITEM)
CO DETECTORS
NEW ADDRESSABLE
NOTIFICATION APPLIANCE CIRCUIT
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
NEMA 1 ENCL
DIGITAL VOICE PANEL W/AMPLIFIER & MICROPHONE
MODULE, BATTERY,BATTERY CHARGER, AND
PROGRAMMABLE MODULE & RELAYS POWER
ADDRESSABLB POINT MODULES AS REQUIRED,
NOTIFICATION CONTROL PANEL 24VDC BUILT-IN
NEW COMBINED ADDRESSABLE FIRE ALARM/ MASS
NEMA 1 ENCL.
WITH BATTERY & BATTERY CHARGER
NEW BUILDING TRANSMITTER
(TYPICAL)
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-14
F O
L
ELEC
MECH
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
SP
SP
SP
C O
N C
R O
A D
ASPHALT ROAD
C P
C P
C P
A-17
1/ 70W HPS LAMP (TYP. OF 2EA)
EXISTING BOLLARD LIGHT, 1PH, 120VAC,
METAL HALIDE LAMP, 1PH, 120V, 60HZ (TYP. OF 2EA)
EXISTING HORIZONTAL FLOOD LIGHT W/70W,
60HZ, 300KVA WITH BUILT-IN PROTECTIVE DEVICE
DEAD FRONT TYPE, 3PH, 22.9KV-120/208V,
METAL ENCLOSED, OIL FILLED, SELF COOLED,
EXISTING PROVIDE NEW PAD MTD TRANSFORMER
LC
A-8 VIA ’LC’
CONTROLLER ’LC’
LIGHTING WIRE TO NEW LIGHTING
CONNECT EXISTING EXTERIOR
NEW LIGHTING CONTROLLER ’LC’,
CONC ENCASED DUCT
EXISTING 2#10 & 1#12(G) IN 27DIA PVC
CONDUIT
EXISTING 2#10 & 1#12(G) IN 27DIA PVC
- E14
S-1
N O T T O S C A L E
ELECTRICAL SITE PLAN
ELECTRICAL SITE PLAN
VIA ’LC’
A-10, 17
EXISTING PANELBOARD "MDP"
EXISTING LOAD CENTER "A"
1#2/0(G) IN103dia PVC CONDUIT)
2 SETS OF(4-500KCMIL &
EXISTING U/G SEC LINE
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
(TYP. OF 16EA)
1PH,120V, LED LAMP ON 7.5M ALUMINIUM POLE
EXISTING POLE MOUNTED PARKING-LOT LIGHT,
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 17 - 10
22 MAY 17
CAMP CARROLL
KIM, CK
E-15
TMGB
WHM
- E15
S-1 ELECTRICAL POWER SINGLE LINE DIAGRAM
N O T T O S C A L E
1#2/0(G) IN 103MM PVC CONDUIT
EXISTING U/G SEC LINE 2 SETS OF 4-500KCMIL &
EXISTING GROUND ROD
EXISTING PRIMARY UNDERGROUND CABLE
EXISTING CURRENT TRANSFORMERS (600:5)
NEMA 4X ENCL. WITH GROUDING WIRE CONNECTION
FOR REMOTE MONITORING, NO OF DIALS ON REGISTER: 4,
3PH-4W-208Y/120V CIRCUIT, AND COMMUNICATION OPTION
WITH FOR USE ON
NEW WATTHOUR METER, SELF-CONTAINED, 120VY, 2.5A,
G
EXISTING GROUND ROD
ELECTRICAL ROOM
COMMUNICATION ROOM
1-#2/ 0 AWG (G) IN 28MM RMC
EXISTING GROUNDING WIRE1#2/0(G) IN 103MM RMC
EXISTING SEC LINE 2 SETS OF 4-500KCMIL &
3P
600AF
600AT
3P
225AF
150AT
M
IN 53 MM RMC
"THW" & 1-#6 AWG (G)
EXISTING 4-#1 /0 AWG
3P
225AF
150AT
3P
100AF
C
3P
100AF
B
3P
100AF
A
3P
400AF
250AT
M
3P
100AF
3P
100AF
3P
100AF
100AT
KA
T
IN 42 RMC
& 1-#8 AWG (G)
NEW 4-#3 AWG "THW"
GROUNDING BUSBAR
NEW TELECOMMUNICATION MAIN
1-#3/0 AWG "BC" IN 22MM RMC
NEW GROUNDING WIRE
ELECTRICAL POWER SINGLE LINE DIAGRAM
OUTDOOR
70AT 60AT
(G) IN 54 MM RMC
AWG "THW" & 1-#6 AWG
REMOVE EXISTING 4-#1 /0
IN 36 MM RMC
"THW" & 1-#8 AWG (G)
EXISTING 4-#4 AWG
IN 36 MM RMC
"THW" & 1-#10 AWG (G)
EXISTING 4-#4 AWG
SPARE SPARE
40AT 40AT
EXISTING PANELBOARD "MDP"
EXISTING LOAD CENTER "C"EXISTING LOAD CENTER "B"EXISTING LOAD CENTER "A" EXISTING LOAD CENTER "M"
REMOVE EXISTING PANELBOARD "KA"
3PST, 240V-400A
REMOVE EXISTING SAFETY SWITCH,
(MECH. ITEM)
REMOVE EXISTING CHILLER
(G) IN 54 MM RMC
AWG "THW" & 1-#6 AWG
REMOVE EXISTING 4-#1 /0
NEW PANEL BOARD "T"
OF PANEL BOARD "MDP"
100AT/100AF IN SPACE
NEW CIRCUIT BREAKER,
G
GNDSN
BUILT-IN PROTECTIVE DEVICE
22.9KV-120/208V, 60HZ, 300KVA WITH
COOLED, DEAD FRONT TYPE, 3PH,
METAL ENCLOSED, OIL FILLED, SELF
EXISTING PAD MTD TRANSFORMER,
FOR THAAD/2-1 ADA BATTERIEX, BLDG. #998
CONVERT THE EXISTING ACS BUILDING TO COF
100AT
IN 42 MM RMC
"THW" & 1-#8 AWG (G)
NEW 4-#3 AWG
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION