1.
4.
2.
6.
5.
3.
& CONDUIT WITH NEW.
PLATES, TERMINAL BLOCKS, ACCESSOREIS AND ASSOCIATED WIRE
TELEPHONE TERMINAL CABINET, TELEPHONE OUTLETS W/COVER
REPLACE DETERIORATED EXISTING TELEPHONE SYSTEM INCLUDING
GENERAL NOTES
1.
2.MOUNTING HEIGHTS ABOVE FLOOR SHALL BE AS FOLLOW UNLESS OTHERWISE
NOTED ON THE DRAWING.
LIGHTING FIXTURE SEE LIGHTING FIXTURE SCHEDULE
PANELBOARD SEE SPECIFICATION
SAFETY SWITCH 1524mm TO CENTER OF THE ENCL
RECEPTACLE,TELEPHONE OUTLET 305mm TO CENTER OF THE ENCL
MOTOR CONTROLLER 1524mm TO CENTER OF THE ENCL
1676mm TO CENTER OF THE ENCL
2286mm TO CENTER OF BELL
3.
4.
6.THE SOIL RESISTANCE TO GROUND FOR THE ELECTRICAL AND COMMMUNICATION
SYSTEMS SHALL BE 25 OHMS OR LESS. THE SOIL RESISTANCE TEST SHALL BE
7.
COORDINATED WITH THE CENTRAL FIRE DEPARTMENT SO THAT
THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING
ON CEILINGDETECTOR
1372mm TO CENTER OF STATIONMANUAL PULL STATION
5.
CONDUCTED BY THE CONTRACTOR TO OBTAIN THE REQUIRED SOIL RESISTANCE.
A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS;
1219mm TO CENTER OF THE ENCLWALL SWTICH
CONDUIT UNLESS OTHERWISE INDICATED.
ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG. "TW" IN 16C
AND LOCATION OF THE F/A ANTENNA WITH THE CENTRAL FIRE DEPARTMENT
THE CONTRACTOR SHALL SUBMIT THE SHOP DRAWING FOR THE MOUNTING
TO TRANSMIT THE ALARM RADIO SIGNAL WAVE WITHOUT ANY OBSTRUCTION.
DETAIL OF THE F/A ANTENNA, AND COORDINATE THE MOUNTING HEIGHT
F/A EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.
THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
SCOPE OF WORKS
LEGEND, GENERAL NOTES AND
E-1
SCOPE OF WORK
F/A & MNS EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.
THE MANUFACTURER AND MODEL OF NEW F/A& MNS EQUIPMENT SHALL BE
F/A &MNS CONTROL
COMBO. SPEAKER & STROBE
12.
13.
14.
A. REPAIR/MAINTENANCE ( K )
10.
11.
8.
9.
15.
SINGLE POLE TOGGLE SWITCH, 15A-125V
L E G E N D
FLEXIBLE CONDUIT W/CONNECTORS
LIGHTING
WIRING
POWER
INTERIOR
S
SYMBOL DESCRIPTION
DESCRIPTION
DESCRIPTIONSYMBOL
SYMBOL
C CONTROL CIRCUIT
3-WAY SWITCH, 15A-125V
AND GOVERNMENT INSTALLED
GOVERNMENT FURNISHED
GFGI
WEATHERPROOFWP
LA LIGHTNING ARRESTER
EXPLOSIONPROOFEP
DISTRIBUTIONDIST
GROUND FAULT PROTECTIONGFP
A AMPERE
AC ALTERNATING CURRENT
AF/AT AMPERE FRAME/AMPERE TRIP
AWG AMERICAN WIRE GAUGE
BC BARE COPPER
BLDG BUILDING
BRKR BREAKER
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CONN CONNECTION
CT CURRENT TRANSFORMER
DET(S) DETAIL(S)
DIAG DIAGRAM
DISC DISCONNECT
DWG(S) DRAWING(S)
EA EACH
EM EMERGENCY
ENCL ENCLOSURE
EXST EXISTING
F/A FIRE ALARM
FL FLOOR
FLUOR FLUORESCENT
FXTR FIXTURE
GEN GENERATOR
GND GROUND
HP HORSE POWER
HZ HERTZ
INCAND INCANDESCENT
INSTL INSTALLATION
J-BOX JUNCTION BOX
K KILO
KV KILO VOLT
KVA KILO VOLT AMPERE
LTG LIGHTING
MAG MAGNETIC
MAX MAXIMUM
MIN MINIMUM OR MINUTE
MTG MOUNTING
NO NUMBER
O/H OVER HEAD
PH PHASE
PNLBD PANELBOARD
PRIM PRIMARY
PWR POWER
Q'TY QUANTITY
RCPT RECEPTACLE
REQ'D REQUIRED
SCHED SCHEDULE
SEC SECONDARY
SPEC SPECIFICATION
STD STANDARD
SW SWITCH
TEL TELEPHONE
TYP TYPICAL
U/G UNDERGROUND
V VOLT
VA VOLT AMPERE
W WATT
W/ WITH
XFMR TRANSFORMER
& AND
CABNET TYPE, RATED WATT ON LTG SCHEDULE
LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER
ON LTG SCHEDULE, WET LOCATION
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
3S
HOMERUN CIRCUIT TO PANELBOARD
TYPE OF MTG ON LTG SCHEDULE
EXTERIOR LED LIGHTING FIXTURE, RATED WATT &
ABBREVIATION
THE COTNRACTOR SHALL SUBMIT A SHOP DRAWING OF HVAC SYSTEM
IN ACCORDANCE WITH SEQUENCE OF OPERATION INDICATED ON THE
MECHANICAL DRAWINGS.
ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2-#12AWG
WIRES IN 16C CONDUIT UNLESS OTHERWISE INDICATED.
THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR
ELECTRICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.
CEILING.
ALL WIRING SHALL BE CONCEALED ABOVE CEILING WHEN THE ROOM HAS
CATV BEFORE CONSTRUCTION.
CONTRACTOR SHALL COORDINATE WITH AREA MP, DO IMO, SIGNAL BRIGADE,
AND GOVERNMENT ACCEPTANCE.
PANELBOARD DOOR, REQUIRED BEFORE FINAL BUILDING INSPECTION
CONTRACTOR SHALL MAKE CIRCUIT CHARTS AND ATTACH THEM TO
FIRE CODE AND SPECIFICATIONS.
OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,
ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS
OR RENOVATION.
CONDITION AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFING ALL EXISTING
FIXTURE A MINIMUM DISTANCE OF 458mm.
FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING
FMCP
FTR
ANTENNA
AUXILIARY
DESCRIPTION
F
TELEPHONE OUTLET
SYMBOL
CATV SYSTEM CABINET
CATV OUTLET
ADDRESSABLE FA MANUAL PULL STATION
WP
F M
TTC
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
TV
MOUNTED TYPE
F/A & MASS NOTIFICATION SPEAKER "WP" WALL
STROBES
WALL MOUNTED SPEAKER /COMBO. (FA+MNS)VISUAL
CONNECTION
BUILDING TRANSMITTER UNIT FOR FIRE ALARM
SYSTEM
F FIRE ALARM SYSTEM CIRCUIT
WIRING FOR TELEPHONE LINET
BRANCH CIRCUIT, EXPOSED ON CEILING OR WALL
WIRING CONCEALED IN THE CEILING AND WALL
F/M
PHOTOCELL
W/EMERGENCY UNIT
WIRING TO UPSTAIR OR DOWNSTAIR
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
UNITS.
CERTIFICATE FROM MANUFACTURER FOR LED LIGHTING FIXTURES AND POWER
CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE 10YEARS WARRANTY
16.
THE GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE
WIDTH OF DUCT EXCAVATION.
AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.
TO THEIR ORIGINAL CONDITION AND OPERATION DURING
ALL DAMAGED AREA INCLUDING SODDING, UTILITIES, STRUCTURES
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING
REPAIR BLDG S-2607
CAMP CASEYTAK, YS
131607
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
J JUNCTION BOX
MAGNETIC MOTOR STARTER
F FAN MOTOR (UNDER MECH. ITEM)
M MOTOR (UNDER MECH. ITEM)
UH
S
WHM
MANUAL MOTOR STARTER W/PILOT LAMP
UNIT HEATER (UNDER MECH. ITEM)
WATTHOUR METER
SAFETY SWITCH
S
TS TAMPER SWITCH (UNDER MECH. ITEM)
FS FLOW SWITCH (UNDER MECH. ITEM)
ENCLOSED CIRCUIT BREAKER
PANELBOARD (OR LOAD CENTER)
THERMOSTAT (UNDER MECH. ITEM)T
3-POSITION SELECTOR SWITCH(H-O-A)
MANUAL MOTOR STARTER W/PILOT LAMP AND
GROUNDING TYPE WITH PLUG
SINGLE RECEPTACLE, 3P-4W-50A-125/250V,
GROUNDING TYPE WITH PLUG
SINGLE RECEPTACLE, 3P-4W-30A-125/250V,
GROUNDED FAULT PROTECTED TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V,
GROUNDING TYPE
SINGLE RECEPTACLE, 2P-3W-20A-125V,
GROUNDING TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V,
TELEPHONE TERMINAL CABINET
CATV
17.
SCHEDULE.
ARC-FAULT CIRCUIT INTERRUPTER TYPE AS INDICATED IN PANELBOARD
SINGLE PHASE, 120V, RECEPTACLES AND LIGHTS IN EACH BEDROOM WITH NEW
CONTRACTOR SHALL REPLACE EXISTING 20A CIRCUIT BREAKERS SUPPLYING
SWITCHES, WIRES AND CONDUITS WITH NEW.
CONTROLS, HAND-OFF-AUTO SELECTOR SWITCHES, 3-WAY
LIGHTS, EXTERIOR LIGHTS, TOGGLE SWITCHES, PHOTOCELL
REPLACE DETERIORATED EXISTING LIGHTING FIXTURES, EXIT
AND CONDUITS FOR MECHANICAL HVAC SYSTEM WITH NEW.
MOTOR STARTER, JUNCTION BOXES, CONTROL/POWER WIRES
CONTROL PANEL, MAGNETIC MOTOR STARTERS, MANUAL
REPLACE DETERIORATED EXISTING SAFETY SWTICH, MASTER
CONDUIT.
(WATTAGE AS REQ'D) DEVICE AND ASSOCIATED WIRING AND
ANTENNA, VISUAL/SIGNAL STROBES, MICROPHONE, SPEAKER
SMOKE DETECTOR & RELAY MODULE, BUILDING TRANSMITTER,
NOTIFICATION SYSTEM PANEL, MANUAL PULL STATION,
WITH NEW ADDRESSABLE FIRE ALARM CONTROL AND MASS
REPLACE DETERIORATED FIRE ALARM CONTROL SYSTEM
WITH NEW.
BOXES, CATV OUTLETS W/ COVER PLATE & CABLE AND CONDUIT
REPLACE EXISTING CATV CABINETS AND ACCESSORIES, PULL
W/COVER PLATES ASSOCIATED WIRING & CONDUITS WITH NEW.
ALARM/MASS NOTIFICATION CONTROL SYSTEM, RECEPTACLES
METER W/CT'S, ENCLOSED CIRCUIT BREAKER FOR FIRE
REPLACE EXISTING PANELBOARDS, ADVANCED WATTHOUR
INDICATEDS 2 #12AWG & 1#1(G) IN 16C
INDICATEDS 3 #12AWG & 1#1(G) IN 16C
INDICATEDS 4 #12AWG & 1#1(G) IN 16C
INDICATEDS 5 #12AWG & 1#1(G) IN 16C
INDICATEDS 6 #12AWG & 1#1(G) IN 16C
UPUP
FEC
W WD D
LS
LS
SS
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
STAIR-1
STAIR-2
MECH ROOM
LAUNDRY RM
DN
DF
DN
REF
SS
FEC
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
DAY ROOM
CORRIDOR
STAIR-1
STAIR-2
J/C
E-2
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
NEW 1ST & 2ND FL LIGHTING PLAN
S
S
SS
S
S
S
S S
S
S
"H-O-A", 120VAC, 15A, "WP" COVER PLATE W/NEW
REPLACE LIGHT TOGGLE SWITCH
WIRING.
1PH, 120V, 100W, MAX. W/ ASSOCIATED
REPLACE PHOTO ELECTRIC CONTROL
1/100SCALE :
NEW 2ND FL LIGHTING PLAN
NEW 1ST FL LIGHTING PLAN
SCALE : 1/100
S a
S
S
S S
S b a b
S a ab a
S
S
S S
S b a b
S a ab ba
S
S
S S
S b a b
S a ab a b
S a b
S
S
S S
S a b
S a b
S
S
S S
S a b
S a b
S
S
S S
S
L1-5
L1-3,5
L1-1
L2-1,3
L2-3
L2-7 L2-5,7
JANITOR
SPRINKLER
REPLACE EXISTING PANELBOARD "L1"
REPLACE EXISTING PANELBOARD "L2"
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
3S 3S3S 3S
SS
S
S a b 3
S
S a b
S
S a b3
S
S a b3 S
S a b3
S
S a b ab 3S 3S b 3S 3S ab 3S 3S b 3S 3S
3S 3S ba3S 3S ba3S 3S ba3S 3S ba3S 3S ba3S 3S ba
S
S a b3
S
S a b
S
S a b 3
S
S a b3 S
S a b 3
S
S a b
E-3
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
NS-6
NS-4a & 4b
245mm
254mm
ELECTRICAL
LIGHTING FIXTURE DETAILS
FIXTURE, 1PH, 120V, 20W, WITH CONVERTER &
CEILING RECESSED LIGHT EMITTING DIODE (LED)
143.9mm
.3 m m
210mm
WALL
NS-7
NS-9
NS-5
NS-8
NS-10
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
UNDERCABINET LED LIGHT FIXTURE
1PH, 120V, 18W, CONVERTER AND ACCESSORIES,
UL LISTED POWER UNIT
CEILING SURFACE/PENDANT MOUNTED LIGHT EMITTING DIODE (LED)
FIXTURE, 1PH, 120V, 45W, UL LISTED, WITH CONVERTER AND
DIODE(LED) EXIT LIGHT FIXTURE 1PH, 120V, 4.99W
WALL SURFACE MOUNTED LIGHT EMITTING
(MAX. INPUT), BATTERY BACK-UP WITH BATTERY CHARGER,
NS-3
SINGLE FACE
ACCESSORIES AS REQUIRED AND EM UNIT
WALL MOUNTED LIGHT EMITTING DIODE (LED) LIGHTING
FIXUTURE 1PH, 120V, 20W LED MODULES, WITH CONVERTER
TYPE, UL LISTED
AND ACCESSORIES W/BUILT-IN PHOTOCELL, WET LOCATION
CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)
FIXTURE, 1PH, 120V, 45W, UL LISTED, WITH CONVERTER &
ACCESSORIES AS REQUIRED, (NS-4a) & WITH EM UNIT (NS-4b)
FIXTURE, 1PH, 120V, 32W, WITH CONVERTER & ACCESSORIES
WALL SURFACE MOUNTED LIGHT EMITTING DIODE (LED)
AS REQUIRED, UL LISTED POWER UNIT
FIXTURE, 1PH, 120V, 18W, WITH CONVERTER & ACCESSORIES,
CEILING SURFACE MOUNTED LIGHT EMITTING DIODE (LED)
WET LOCATION SHOWER LIGHT TRIM, UL LISTED POWER UNIT
ACCESSORIES, AS REQUIRED AND UL LISTED
POWER UNIT
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
NEMA 1, ENCL.
W/GREEN COLOR INDICATING LIGHT,
HAND-OFF-AUTO SELECTOR SWITCH
HAND
OFF
AUTO
N
120VAC
1PH, 120VAC, 200W MAX
PHOTO ELECTRIC CONTROL
NS-4 (TYP. OF 7EA)
EXTERIOR LIGHTING FIXTURE
I0
NOT TO SCALE
EXTERIOR LTG CONTROL DIAGRAM
LIGHTING CONTROL DIAGRAM
LIGHTING FIXTURE SCHEDULE & EXTERIOR
ROOM NAME
WATTS TYPE SHT NO
REMARKSLAMP TYPE
QTY (EA)
ROOM NO
IMA-KORO STD. DET. 40-06-04
CEILING RECESSEDBED ROOM101~106
LIGHTING FIXTURE SCHEDULE
LAUNDRY107
JANITOR
SPRINKLER RM
MECHANICAL ROOM
BED ROOM201~206
208 JANITOR
227 CORRIDOR
OUTDOOR LIGHT
EXIT LIGHT
WALL MOUNTING
CEILING RECESSED
CEILING SURFACE
CEILING RECESSED
CEILING RECESSED
NS-9
LED 4.99 NS-3 WALL/CEILING MOUNTING
NS-4a
NS-4b
NS-4b
NS-4a45
20 NS-6
NS-5
NS-7
LED
LED
LED
LED
CEILING RECESSED, EMERGENCY BATTERY UNIT
CEILING RECESSED
ABOVE MIRROR TOP
CEILING RECESSED, EMERGENCY BATTERY UNIT
18 NS-7
LED
LED
LED
LED
LED
LED 1
45 NS-4b
NS-4a
CEILING RECESSED, EMERGENCY BATTERY UNIT
NS-10
EMERGENCY BATTERY UNIT
CEILING SURFACE MOUNTED,
LED
LED
LED
LED
LED
LED
LED 18
45 NS-4a
NS-4b
NS-6
NS-5
NS-7
CEILING RECESSED, EMERGENCY BATTERY UNIT
CEILING RECESSED
ABOVE MIRROR TOP
CEILING SURFACE MOUNTED
CEILING SURFACE MOUNTED
LED
DAY ROOM
45 NS-4b
NS-4a 2
CEILING RECESSED
CEILING RECESSED, EMERGENCY BATTERY UNIT
18 NS-7 1 CEILING SURFACE MOUNTED
LED
LED NS-4b45
45 NS-4a CEILING RECESSED
CEILING RECESSED, EMERGENCY BATTERY UNIT
E-4
NS-8 1 UNDER CABINET
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
LED
LED 45
LED 18
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
E-5
UPUP
FEC
W WD D
LS
LS
SS
RM
SPRINKLER
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
STAIR-1
STAIR-2
MECH ROOM
LAUNDRY RM
DN
DF
DN
REF
SS
FEC
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
DAY ROOM
CORRIDOR
STAIR-1
STAIR-2
J/C
1/100SCALE :
SCALE : 1/100
S T
J
S T
J
S T
TS
S T
J
TS
J
F
TS
S T
S
J
F
T S
J
F
TS
0 T
S
J
F
TS
L2-2,4
L2-10
NEW 1ST FL POWER PLAN
NEW 2ND FL POWER PLAN
EXHAUST FAN CONTROL DIAGRAM
NEW 1ST & 2ND FL POWER PLAN, ROOF
L1-2 L1-7,9
L1-2,4
L1-2,4,6 L1-9
L1-8,10
L1-8
L1-8,10,12
L1-11 L1-13 L1-15
L1-14 L1-16
L1-24
L1-21
L2-2 L2-2,4,6
L2-15
L2-8
L2-11
L2-12
L2-11,13
L2-20 L2-17
L2-19
L2-9
L2-21
JANITOR
REPLACE EXISTING PANELBOARD "L2"
REPLACE EXISTING PANELBOARD "L1"
T
F
I0
ROOF VENTILATOR
FIRST FLOOR
SECOND FLOOR
NOT TO SCALE
N
(TYPICAL)
TIME SWITCH, 30MIN
EXHUAST FAN CONTROL DIAGRAM
Ref. Ref.
L1-26
L1-25
L1-28
L1-27 L1-30L1-29
L2-30L2-29
L2-28
L2-27
L2-26
L2-25
Ref. Ref. Ref. Ref. Ref. Ref.
Ref.Ref.Ref.Ref.
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
E-6
UPUP
FEC
W WD D
LS
LS
SS
RM
SPRINKLER
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
STAIR-1
STAIR-2
MECH ROOM
LAUNDRY RM
DN
DF
DN
REF
SS
FEC
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
DAY ROOM
CORRIDOR
STAIR-1
STAIR-2
J/C
1/100SCALE :
SCALE : 1/100
JJ
TT
J J J
J
T
J J
T
J
TT
J JJ
T
J
F
MMS-1
MMS-4
J
T
TO MCP TO MCP
TO MCP C
C
C
C
C
C
J
J
MMS-3
M C
P
"M"OARC
TH O
DM
J
J
J
J
MMS-2
JJ
TT
J J J
T T
JL1-17
L1-17,19
J
TT
J
JJJJ
HOT & CHILLED CIRC. PUMP
DOMESTIC HOT WATER HEATER CIRC. PUMP
DOMESTIC HOT WATER HEATER RE-CIRC. PUMP
PULL BOX 104mmX208mmX310mm
FLOW SWITCH
WALL VENTILATOR
DOMESTIC HOT WATER HEATER
3-WAY MIXING VALVE
HOT WATER HEATING BOILER2
MECH. ROOM CONTROL PLAN
SCALE : 1/50
MECH. EQUIPMENT SCHEDULE
SYMBOL DESCRIPTIONQ'TY
DOMESTIC HOT WATER HEATER PUMP MOTOR
PUMP MOTOR
"MMS-1"
ITEM NO.
"MMS-2"
UTILITY NO.
NOTES FOR THIS SHEET ONLY
1.
MAGNECTIC MOTOR STARTER SCHEDULE
FAN MOTOR 1/22HP, 115 V, 1 PH, 60 HZ
1/3 HP, 115 V, 1 PH, 60 HZ,
"MMS-3"
"MMS-4"
THE SEQUENCE OF OPERATION ON THE MECHANICAL DRAWING.
FOR CONTROL OF HEATING AND AIR CONDITIONING SYSTEM ACCORDING TO
THE CONTRACTOR SHALL BE RESPONSIBLE TO PREPARE SHOP DRAWINGS
FAN & MOTOR
COMPRESSOR
1/8 HP, 115 V, 1 PH, 60 HZ,
PUMP MOTOR
DOMESTIC HOT WATER CIRCULATION PUMP
DOMESTIC HOT WATER RE-CIRCULATION PUMP
(A1) 32.7 RLA, (B1) 2EA-40.8RLA
208V, 3PH, 60HZ, EA-2KW
HOT / CHILLED WATER CIRCULATION PUMP 3/4 HP, 208 V, 3 PH, 60 HZ,
1/12 HP, 115 V, 1 PH, 60 HZ,
PUMP MOTOR
WALL VENTILATOR (MECHANICAL ROOM)
NEMA1 ENCL.
"HAND-OFF-AUTO" SELECTOR SWITCH & PILOT LAMP, COIL VOLTAGE 120VAC,
3P-208VAC-60HZ-3/4HP, NEMA SIZE 0, "START-STOP" PUSH BUTTON SWITCH,
COMBINATION STARTER, CIRCUIT BREAKER TYPE, W/MELTING ALLOY OVERHEAD RELAYS,
NEMA 1 ENCL.
"HAND-OFF-AUTO" SELECTOR SWITCH & PILOT LIGHT, COIL VOLTAGE 120VAC,
1P-115VAC-60HZ-1/3HP-NEMA SIZE 00,"START-STOP" PUSH BUTTON SWITCH,
MAGNETIC MOTOR STARTER, W/MELTING ALLOY OVERLOAD RELAYS,
NEMA 1 ENCL.
"HAND-OFF-AUTO" SELECTOR SWITCH & PILOT LIGHT, COIL VOLTAGE 120VAC,
1P-115VAC-60HZ-1/12HP-NEMA SIZE 00,"START-STOP" PUSH BUTTON SWITCH,
MAGNETIC MOTOR STARTER, W/MELTING ALLOY OVERLOAD RELAYS,
NEMA 1 ENCL.
"HAND-OFF-AUTO" SELECTOR SWITCH & PILOT LIGHT, COIL VOLTAGE 120VAC,
1P-115VAC-60HZ-1/22HP-NEMA SIZE 00,"START-STOP" PUSH BUTTON SWITCH,
MAGNETIC MOTOR STARTER, W/MELTING ALLOY OVERLOAD RELAYS,
2 PUMP MOTOR 1/8 HP, 115 V, 1 PH, 60 HZ, HOT WATER HEATING BOILER
L2-14,16
11 WALL VENTILATOR
6 HOT & CHILLED CIRC. PUMP
8 DOMESTIC HOT WATER HEATER RE-CIRC. PUMP
MECH. ROOM POWER PLAN
SCALE : 1/50
DOMESTIC HOT WATER HEATER
AIR COOLED LIQUID CHILLER
PACKAGED
J F
"M"
PULL BOX 104mmX208mmX310mm
4-#2 AWG IN 42mm CONDUIT W/NEW
REPLACE UNDERGROUND WIRES
3-WAY MIXING VALVE
OARC
TH O
FS
HOT WATER HEATING BOILER2
DOMESTIC HOT WATER CIRC. PUMP
M-9 T
MMS-4
M-3
M-6
J
M-8
J MMS-1
J
MMS-2
M-1
M-2
J
M-4 M-5
MMS-3
J
DM
AIR-COOLED CHILLER
NEW 1ST FL FAN COIL UNIT PLAN
NEW 1ST & 2ND FLOOR FAN COIL UNIT PLAN,
MECH. ROOM POWER & CONTROL PLAN,
MAGNETIC MOTOR STARTER SCHEDULE AND
MECH EQUIPMENT SCHEDULE
FCU FCU
L2-14
W H
M
SWITCH AND RELAY.
HAND-OFF-AUTO SELECTOR
WITH H-O-C SELECTOR SWITCH,
MASTER CONTROL PANEL;
EXISTING MAIN PANEL BOARD "M"
JANITOR
J
T L2-23
(TYPICAL)
110W, 115V, 1PH, 60HZ
FAN COIL UNIT
(TYPICAL OF 2EA)
1000W, 120V, 1PH, 60HZ
ELEC. UNIT HEATER,
L2-24 J
T
AIR COOLED LIQUID CHILLER
FCU FCU FCU FCU FCU FCU
FCUFCUFCUFCU
FCU FCU FCU FCU FCU FCU
FCUFCUFCUFCUFCUFCUFCU
REMOTE CONTROLLER & WIRE
REMOVE/REINSTALL CHILLER
REPLACE EXISTING PANELBOARD "L2"
REPLACE EXISTING PANELBOARD "L1"
P
HT J
2KW
60HZ, 1/20HP, HEATING CAPCITY
ELEC. UNIT HEATER, 120V, 1PH,
S
NEMA 3R ENCL. W/NEW
3PST-200A-240V, 150A FUSEX3EA,
REPLACE SAFETY SWITCH
W/NEW
FUSEX3EA, NEMA 3R ENCL.
3PST-200A-240V, 150A
REPLACE SAFETY SWITCH
M-6
C
C
FS
P
EXISTING MAIN PANEL BOARD "M"
REGISTER NEMA 3R ENCL.
W/CTs(300:5A)x3EA, 15MIN DEMAND
HOUR METER, 3PH, 4W
NEW ADVANCED DIGITAL WATT
W H
MREGISTER NEMA 3R ENCL.
W/CTs(300:5A)x3EA, 15MIN DEMAND
HOUR METER, 3PH, 4W
NEW ADVANCED DIGITAL WATT
1PH, 1HP MAX. NEMA 1 ENCL.
NEW MANUAL MOTOR STARTER, 120V,
NEW 2ND FL FAN COIL UNIT PLAN
PROVIDE POWER WIRING
OIL LEAKING MONITORING PANEL/
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
DAMPER
T
T
J
J
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
E-7
ELECTRICAL
NEW PANELBOARD "L1" & "L2" LOAD
SCHEDULE
3PH, 4W, 120/208V SN & GND 60HZ
FLUSH MTG, NEMA 1 ENCL
LOAD DESCRIPTION
A B C
P H A S E CKT. BRKR
AT AICAFP
DIAGRAM
TOTAL
LOAD
(VA)
WIRE
SIZE
(AWG)
CKT
NO.
S/N
GND
B C N GA
3 4
5 6
7 8
11 12
15 16
17 18
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
10KLIGHTS #12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
LIGHTS
LIGHTS
1 2
#12
360 360
360 360
RECEPTACLE 5-180VA 900 900
RECEPTACLE 5-180VA
579 579
667 667
RECEPTACLE & VENT
RECEPTACLE & VENT 579 579
5-180VA 900 900
1-1/4HP
FAN COIL UNIT 6-110W
2-1/4W
360360
660 660
FAN COIL UNIT 6-110W 660 660
1-12KW 5,000
1 100 20
100 20
1 100 20
1 100 20
#12
#12
#12
2,500
2,500
REFRIGERATOR
579 579
3P
100AF
100AT
771 771
LIGHTS
RECEPTACLE 720
900 900
CATV CONTROL
CATV
500 500 2
2 50
1 20
3-180VA
5-180VA
4-180VA
RECEPTACLE
RECEPTACLE
RECEPTACLE & VENT
5-180VA RECEPTACLE
FOOD FAN 600W
500W 500
MICROWAVE OVEN 1,000W 1,0001,000
1,0001,000W
#8
#12
4-1/20W, 2-1/18W
4-1/45W, 2-1/32W, 4-1/20W, 2-1/18W
4-1/45W, 2-1/32W, 4-1/20W, 2-1/18W
4-1/45W, 2-1/32W, 1-1/12HP
2-180VA,
1-1/12HP
2-180VA,
1-1/12HP
2-180VA,
1-1/18W, 7-1/32W
11-1/45W, 1-2/13W, 900 900
600 600
ELEC. HEATER 1,000W 1,000 1,000
ELEC. HEATER 1,000W 1,000 1,000
RECEPTACLE
CIRCUIT BREAKERS FOR RECEPTACLES AND LIGHT SHALL BE ARC FAULT CIRCUIT INTERRUPTOR(AFCI)
NEW PANELBOARD "L2" LOAD SCHEDULE
(VA)
3T O T A L
DEMAND LOAD : DEMAND FACTOR :
3PH, 4W, 120/208V SN & GND 60HZ
FLUSH MTG, NEMA 1 ENCL
LOAD DESCRIPTION
A B C
P H A S E CKT. BRKR
AT AICAFP
DIAGRAM
TOTAL
LOAD
(VA)
WIRE
SIZE
(AWG)
CKT
NO.
10K
S/N
GND
B C N GA
3 4
5 6
7 8
11 12
15 16
17 18
19 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
360 360 1 100 20
900 900 1 100 20
1 100 20
1 100 20
1 100 20
1 100 20
660 1 100 20
1 100 20
1 100 20
1 100 20
2 100
100 30
36,074
27,564
10KLIGHTS
11,236 11,958
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
LIGHTS
LIGHTS
WASHER
1-1000W
2-180VA
1,130
2,500
1 2
#10
12,880
#12
360 360
RECEPTACLE 5-180VA 900 900
RECEPTACLE
RECEPTACLE
5-180VA
5-180VA
RECEPTACLE & VENT 504 504
IRON 1,000 1,000
5-180VA
9005-180VA 900
FAN COIL UNIT 6-110W 660
FAN COIL UNIT 6-110W 660
WASHER
1,130
1-1/2HP
1-1/2HP
5-180VA
1,130
1,130
DRYER 1-5KW 5,000
DRYER 1-5KW 5,000
2-180VA
2-180VA
360 360
SPARE 900
2,500 2,500
2,500
27 28
#10
900 900
MAIN C.B. 3P-100AF-100AT
3P
100AF
100AT
SPARE
SPARE
4-1/20W, 2-1/18W
4-1/45W, 2-1/32W, 1-1/22HP
2-180VA,
4-20W, 2-18W
6-45W, 3-1/32W, 4-1/20W, 3-1/18W
6-45W, 2-1/32W, #2
RECEPTACLE
RECEPTACLE
RECEPTACLE
RECEPTACLE
RECEPTACLE
RECEPTACLE
NEW PANELBOARD "L1" LOAD SCHEDULE
76.4%
900WTEL. CABINET
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
SPARE
SPARE
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
SPARE
SPARE
33 34
29 30
#12
#12
#12
#12
#12
#12
SPACE
SPACE
SPACE SPACE
SPACE
SPACE
1000 1
SPARE
SPARE
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
SPARE
SPARE
#12
#12
#12
#12
#12
#12
(VA)
3T O T A L
DEMAND LOAD : DEMAND FACTOR :
100 10K10031,215
22,733
10,426 11,239 9,550
MAIN C.B. 3P-100AF-100AT
#2
72.8%
33 34
29 30
SPACE
SPACE
SPACE
SPACE
SPACE
RANGE **
CIRCUIT BREAKER FOR ELEC. RANGE SHALL BE SHUNT-TRIP TYPE TO BE CONTROLLED BY FIRE ALARM CONTROL SYSTEM.**
DN
DF
DN
REF
SS
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
DAY ROOM
CORRIDOR
STAIR-1
STAIR-2
J/C
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
E-8
/COMBO. (FA + MNS) VISUAL SIGNAL STROBES
WALL MOUNTED SPEAKER (WATTAGE AS REQ'D)
"WP" TYPE, WALL MOUNTED TYPE,
FIRE ALARM/MASS NOTIFICATION
SPEAKER (WATTAGE AS REQ'D)
ADDRESSABLE MANUAL PULL STATION
* ADDITIONAL LEGEND (THIS SHEET ONLY)
F
WP
F
M
CEILING MOUNTED TYPE,
FIRE ALARM/MASS NOTIFICATION
SPEAKER (WATTAGE AS REQ'D)
M F
(15 OR 75 CANDELA)
M F
(15 OR 75 CANDELA)
VISUAL SIGNAL STROBES
WALL MOUNTED COMBO. (FA + MNS)
LOC LOCAL OPERATING CONSOLE(LOC)
1/100SCALE :
F M
UPUP
FEC
W WD D
LS
LS
SS
RM
SPRINKLER
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
STAIR-1
STAIR-2
MECH ROOM
LAUNDRY RM
SCALE : 1/100
F
F M
F
LOC
SB SB SB SB SB SB
SBSBSBSBSBSB
FF
WP
F
M
D
F M
C P
F T
R
W P
M F
W P
M F
F
D
D
FS
J
TS
J
J
PS
J
TS
JTSTS J
F F
WP WP WP
D D D TO FMCP
NEW 1ST FL FIRE ALARM/MASS NOTIFICATION SYSTEM PLAN
SEE FIRE ALARM/MASS NOTIFICATION SYSTEM DIAGRAM
FIRE ALARM ANTENNA, ACCESSORIES NEMA 1 ENCL.
NOTIFICATION CONTROL PANEL (FMCP), BUILDING TRANSMITTER,
FS
TSJ
J
JANITOR
F
F F F
F
F
F
F
F
FFFF
F
F
FF
F
F
FF
F
F F
F
F
F
F F/M
F
M
F/MF/M
F/M F/M
F/M
F/M
F/M
F/M
F/MF/M
F/M F/M F/M
F
M
F/M
F
M
NEW 2ND FL FIRE ALARM/MASS NOTIFICATION SYSTEM PLAN
2-1P, 100AF, 20AT, NEMA 1 ENCL.
NEW ENCLOSED CIRCUIT BREAKER W/HANDLE LOCK,
NEW NCOMBINED ADDRESSABLE FIRE ALARM/MASS
REPLACE EXISTING PANELBOARD "L2"
NOTIFICATION SYSTEM PLAN
NEW 1ST& 2ND FL FIRE ALARM/MASS
TO MAIN PANELBOARD, 3#12 & 1#12(G) IN 16C
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
CONN TO SHUNT-TRIP
TYPE CIRCUIT BREAKER
ACTIVATED BY FMCP
FOR ELEC RANGE TO BE
E-9
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
24VDC, BUILT-IN ADDRESSABLE POINTS MODULES AS REQ'D,
(AS REQ'D) & MICROPHONE. NEMA 1 ENCL
DIGITAL VOICE PANEL W/AMPLIFIER & BACK UP AMPLIFIER
BATTERY CHAREGER, POWER MODULES PANEL (AS REQ'D) AND
SYNCHRONIZATION CONTROL MODULE, POWER SUPPLY,
PROGRAMMABLE MODULE & RELAYS, LCD ANNUNCIATOR,
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL (FMCP),
COMBINED ADDRESSABLE
DIGITAL VOICE MODULE, MICROPHONE, BATTERY,
FIRE ALARM/MASS NOTIFICATION
CONTROL PANEL (FMCP)
1st FL.
ROOF FL.
FTR
12#14 IN 21C(FOR SIGNAL)
2#12 IN 16C(FOR POWER)
W/BATTERY & BATTERY
BT-XM AT LEAST 16 ZONES)
CHARGER, NEMA 1 ENCL
#6 "BC" IN 21C
GROUND CONDUCTOR
COAXIAL CABLE
W/CONNECTORS IN 16C
OMNI-DIRECTION TYPE
FIRE ALARM ANTENNA
W/MOUNTING BRACKET
GROUND ROD, COPPER CLAD
WITH WELDING CONNECTION
STEEL, 19mmdia x 3000mmLG
SG
G ~
G
CONTROL PANEL & BOOSTER PANEL)
(INSTALLED BESIDE FIRE ALARM
(RATED AS REQ'D) (TYPICAL)
SURGE PROTECTOR
2#12 & 1#12(G) IN 16C
GROUND ROD, COPPER CLAD
GROUNDING SYSTEM #6, "BC" IN 21C
CONN TO BLDG ELECTRODE
STEEL, 19mmdiax3000mmLG
WITH WELDING CONNECTION AND
INCLUDING MICROPHONE AND
LOCAL OPERATING CONSOLE(LOC)
PUSH BUTTONS, etc.
ENCLOSURE
LIGHTNING ARRESTER
W/WEATHER-PROOF
M F
VISUAL SIGNAL STROBES
AS REQ'D)/COMBO. (FA + MNS)
WALL MOUNTED SPEAKER (WATTAGE
(PROGRAM OF D-21 MONACO
BUILDING TRANSMITTER
ROOF FL.
LOC
202 203
SB
105103110
ADDRESSABLE MANUAL
PULL STATION (TYPICAL)
ADDRESSABLE SMOKE
DETECTOR W/SOUNDER
BASE (TYPICAL)
WALL MOUNTED "WP" TYPE,
NOTIFICATION SPEAKER
FIRE ALARM/MASS
(WATTAGE AS REQ'D) (TYPICAL)
FIRE ALARM/MASS NOTIFICATION
SPEAKER (WATTAGE AS REQ'D)
CEILING MOUNTED TYPE,
FOR ABBREVIATION, LEGEND, AND GENERAL NOTES1.
STROBES (75 CANDELA)
(TYPICAL)
(FA + MNS) VISUAL SIGNAL
WALL MOUNTED COMBO.
109 104 107 106
ADDRESSABLE SMOKE
HEAT DETECTOR RATE
(TYPICAL)
HEAT DETECTOR RATE
F
204 207
FIRE ALARM/MASS NOTIFICATION SYSTEM DIAGRAM
NOT TO SCALE
TS
J
FS
J
TS
J
PS
J
TS
J
TS
J
FS
J
TS
J
207 207
109 109 109 109 109
ELECTRICAL
SEE SHEET NO E-1.
BY UFC-4-021-01.
18.
TO ACHIEVE A MINIMUM CIS SCORE 0.8 AS REQUIRED
THE CONTRACTOR SHALL PROVIDE THE REQUIRED TESTING
28.31.76.00.31 (MNS) AND NFPA 72.
SHUTDOWN MANUALLY.
INITIATED MESSAGES. MASS MESSAGE IS REQUIRED TO BE ANNOUNCED IMMEDIATELY UNTIL
THIS SEQUENCE IS REQUIRED FOR BOTH PRE-RECORDED MESSAGES AND MANUAL MICROPHONE
MASS ALERT IS CANCELED MANUALLY ON THE PANEL BY SWITCH.
AUTOMATICALLY AND CONTINUE TO OVERRIDE THE FIRE NOTIFICATION APPLIANCES UNTIL
THE MASS SYSTEM ACTIVATION MUST OVERRIDE THE FIRE ALARM NOTIFICATION APPLIANCES
NFPA 72, 6.9.3.2 & 6.9.10.2.
NEEDS TO HAVE PRE ALERT CONTINUOUS 3-10 SECOND TONE,
16.
"FIRE" AND W/CLEAR LENS. SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH SPECIFICATION SECTION
"ALERT" IN RED LETTER AND W/AMBER LENS.
ABILITY TO TEMPORARILY DEACTIVATE FIRE ALARM AUDIO
NOTIFICATION APPLIANCES WHILE DELIVERING VOICE MESSAGES.
STROBES FOR FIRE ALARM SHALL BE MARKED
STROBES FOR MASS NOTIFICATION SHALL BE MARKED
17.
7) A TEST MESSAGE INTENDED FOR VERIFYING FUNCTIONALITY OF THE SYSTEM
5) EMERGENCY WEATHER CONDITIONS APPROPRIATE FOR THE LOCAL AREA
4) EVACUATION OF THE BUILDING USING EXITS OTHER THAN THE NORMAL MAIN ENTRANCE/EXIT
2) INTRUDER/HOSTILE PERSON SIGHTED WITHIN/AROUND THE BUILDING
1) BOMB THREAT OR ACTUAL BOMB WITHIN/AROUND THE BUILDING
ARE IN ENGLISH AND HANGUL AT LEAST FOR THE FOLLOWING ITEMS.
THE MASS NOTIFICATION SYSTEM SHALL BE ENSURED THAT PRERECORDED MESSAGES
WITH THE MANUFACTURER'S LISTED INSTALLATION REQUIREMENTS AND WIRE COUNT.
SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION DEVICE LOCATIONS IN ACCORDANCE
THE APPLICABLE CODE, SPECIFICATIONS AND MANUFACTURER'S EQUIPMENT LISTING.
IS THE MINIMUM REQUIRED AND THE FINAL QUANTITY SHALL BE IN ACCORDANCE WITH
THE MASS NOTIFICATION SYSTEM IS CONCEPTUAL. THE NUMBER OF DEVICES SHOWN20.
3) OCCUPANTS DIRECTED TO TAKE COVER WITHIN THE BUILDING
6) "ALL CLEAR" MESSAGE
PER UFC 4-021-01.
19.
22.
21.
15. ADDITIONAL RELAY IS PROVIDED AS REQUIRED.
VOICE EVACUATION MESSAGE NEEDS TO HAVE PRE ALERT
SPECIFICATION SECTION 28.31.64.00.31 (FA) AND NFPA 72.
APPROVED.
ARCHITECTURAL FEATURES.
LOCATIONS AND WIRE COUNT.
IN ACCORDANCE WITH THE APPLICABLE CODE, SPECIFICATIONS
BE PROVIDED WITH CLASS "A" MODULES.
HORIZONTAL AND 305mm VERTICALLY.
TRANSMITTER AND ANTENNA.
ON THE FIRE ALARM/MASS NOTIFICATION CONTROL PANEL COVER.
BREAKER AND/OR DISCONNECT SWITCH.
WIRES FOR THE FIRE ALARM AND DETECTION SYSTEM.
AUDIBILITY CALCULATION, WIRE SIZE, CONDUIT SIZE, NO. OF
SHALL BE RESPONSIBLE FOR PROVIDING FIRE ALARM
THE FIRE ALARM/MASS NOTIFICATION SYSTEM CONTRACTOR
FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED LETTER
"FIRE ALARM CIRCUIT" ON THE DEDICATED POWER CIRCUIT
CIRCUIT AND ROOM LOCATION OF PANEL SHALL BE INDICATED
THE POWER CIRCUIT NUMBER DEDICATED TO FIRE ALARM7.
6.
4.
COAXIAL CABLE SHALL BE ONE PIECE BETWEEN BUILDING11.
SYSTEM SHALL BE SEPARATED BY A MINIMUM OF 1220mm
INCOMING AND OUTGOING CLASS "A" RACEWAY OF FA8.
9. ALL CLASS "A" EXCEPTIONS IN NFPA 72, 6.4.2.2.2 ARE
PROHIBITED FOR ALL IDC, NAC AND SLC.
ALL TAMPER SWITCHES, FLOW SWITCHES, PRESSURE
SWITCHES AND NON-ADDRESSABLE INITIATION DEVICES SHALL
COORDINATE THE EXACT DEVICE LOCATIONS WITH ELECTRICAL
AND MECHANICAL SYSTEM EQUIPMENT AND BUILDING
ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM
VOICE EVACUATION SYSTEM IN LIEU OF TEMPORAL PATTERN
IS REQUIRED FOR FIRE ALARM EVACUATION SYSTEM.
TEMPORAL PATTERN MIN 2 CYCLES AND THE MASS MESSAGE
SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH
10.
12.
13.
14.
THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR
2.
SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION DEVICE
AND MANUFACTURER'S EQUIPMENT LISTING FOR READY TO USE.
THE FIRE ALARM SYSTEM IS CONCEPTUAL.
ALSO CONDUITS SHALL BE RUN AWAY AT LEAST 900mm
(3-FEET) FROM HVAC, HOT & COLD WATER PIPING.
5.
PROVIDED BY THE CONTRACTOR WHEN THE CONTRACTOR SUBMITS
THE VOLTAGE DROP AND POWER SUPPLY CALCULATION SHALL BE
SHOP DRAWINGS.
COMPLETE DESIGN AND INSTALLATION OF THE SYSTEM
NOTES:
RATING OF FA/MNS STROBE.
CONTRACTOR SHALL CALCULATE ADEQUATE CANDELA
BASED ON THE SIZE AND THE USE OF THE ROOM,3.
(15 OR 75 CANDELA) (TYPICAL)
D
SB
F F
D
F
D
D
D
F
101102 F
M
EXT
WP
F M
EXT
WP
M
F
M
F
M
F F M
EXT
WP
205 206
ADDRESSABLE MANUAL
(TYPICAL)
PULL STATION"WP"
WP WP
EXT EXT EXT
WP
209209
209209
IN RM 109TO "EM"
DIAGRAM
FIRE ALARM/MASS NOTIFICATION SYSTEM
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
D
DETECTOR
CONN TO SHUNT-TRIP
TYPE CIRCUIT BREAKER
ACTIVATED BY FMCP
FOR ELEC RANGE TO BE
CONN TO SHUNT-TRIP
TYPE CIRCUIT BREAKER
ACTIVATED BY FMCP
FOR ELEC RANGE TO BE
DN DN
REF
SS
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
DAY ROOM
CORRIDOR
STAIR-1
STAIR-2
J/C
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
E-10
1/100SCALE :
NEW 2ND FL TEL/CATV PLAN
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
UPUP
T T
C
W WD D
LS
LS
SS
RM
SPRINKLER
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
STAIR-1
STAIR-2
MECH ROOM
LAUNDRY RM
NEW 1ST FL TEL/CATV PLAN
SCALE : 1/100
T V T
V
T V
T V
T V T
V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
T V
C C
T V
88 8 2
C C
T V
TO TTC
TO TTC
TO TTC
TO TTC
TO TTC
REMOVE EXISTING CATV OUTLET (TYPICAL)
SINGLE CAT-6, MODULAR JACK
8-PIN(RJ-45 TYPE),
WITH COVER PLATE & LUG
(TYPICAL)
PULL BOX (300mmx300mmx200mmD)
WITH 8-WAY TAP OFF AND LOCKING
DEVICE ABOVE CORRIDOR CEILING
(5-1000MHZ) (TYPICAL)
REMOVE EXISTING CATV CABINET, ANTENNA
REPLACE EXISTING CATV CABINET
762mm(W)x610mm(H)x254mm(D)
TO BE TERMINATED AT "TELEPHONE CABINET"
IN SPRINKLER RM 107 (TYPICAL)
1, 2, 3 OR 4-4PAIR, #24AWG, CAT-6, TEL WIRE IN 27C
PLATE & F-81 BARREL
W/"0"dB LOSS FACE
(MH:+300mm AFF) (TYPICAL)
TYPE CONNECTOR
SHIELDED IN 16C (TYPICAL)
COAXIAL CABLE RG 6/U QUAD
SHIELDED IN 16C (TYPICAL)
COAXIAL CABLE RG 11/U QUAD
W/ ACCESSORIES, NEMA 1 ENCL
600mmW x 600mmH x 300mmD
WEATHER PROOF TYPE
NEW PULL BOX
P
NEW 1ST & 2ND FL TEL/CATV PLAN
EXIST 1-25 PAIR #24 AWG IN 103mm dia C.
T V
T V
T V
T V
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
AND FITTING WITH NEW
REPLACE EXIST 103mm RISER CONDUIT
CONNECTION POINT
NEW WALL MOUNTED TYPE TV OUTLET
TV
TVTV
202202
202 202
TV TVTV
8 209
TV
L2-18
NOTES
RECEPTACLE, AIR VENTS AND
LOCKING DEVICE NEMA 1 ENCL
AMPLIFIERS, 8-WAY SPLITTER-1EA,
BACKBOARD LINE EXTENDER
CATV DISTRIBUTION CABINET
WITH 610mmx610mm W/19THK PLYWOOD
762mm(W)x610mm(H)x254mm(D)
2#12 & 1#12(G)
IN 16C
AMP 8
TV
CTC
G
ROOF
2nd FL.
1st FL.
SURGE SUPPRESSION TYPE SINGLE
RECEPTACLE, 2P-3W-20A-250VAC,
GROUNDING TYPE W/PLUG
FOR TRUNK BRIDGER AMPLIFIER.
(TYPICAL)
FOR TRUNK BRIDGER AMPLIFIER.
SURGE SUPPRESSION TYPE DUPLEX
RECEPTACLE, 2P-3W-20A-125VAC,
GROUNDING TYPE
(TYPICAL)
ROOM NUMBER
WHICH DEVICE IS LOCATED
(TYPICAL)
PULL BOX (300mmx300mmx200mmD)
WITH 8-WAY TAP OFF AND LOCKING
DEVICE ABOVE CORRIDOR CEILING
(5-1000MHZ) (TYPICAL)
EXTERIOR WALL OF 2nd FLOOR
SECOND RACK TO REMAIN ON
EXIST ENTRANCE CAP &
L2-22
MAIN PANELBOARD "M"
CONN TO
GROUNDING BUSBAR
#6 "BC" IN 21C
PLATE & F-81 BARREL
W/"0"dB LOSS FACE
(MH:+300mm AFF) (TYPICAL)
TYPE CONNECTOR
WALL MOUNTED TYPE TV OUTLET
SHIELDED IN 16C (TYPICAL)
COAXIAL CABLE RG 6/U QUAD
CONTRACTOR TO MEET THE REQUIREMENT OF CATV dB.
TESTING OF CATV SYSTEM SHALL BE PERFORMED BY THE1.
MUST HAVE RETURN PATH (2-WAY) CAPABILITIES.
ALL CATV MATERIAL AND EQUIPMENT SHALL BE INSTALLED 2.
TAP UNITS, SPLITTERS, AMPLIFIER, COAXIAL CABLE, etc.
THE SPECIFICATION OF MATERIALS SUCH AS CATV OUTLET3.
SHALL BE MATCHED OR COMPATIBLE WITH THE EXISTING
CATV CONTRACTOR OR MWR OFFICE.
BASE CATV SYSTEM. IT SHALL BE COORDINATED WITH
#NL15DDJ-L06D2G1 OR APPROVED EQUAL.
LINE EXTENDER AMPLIFIERS SHALL BE C-COR PART4.
PROVIDE DIAGONAL VENTS ON OPPOSITE SIDE PANEL,
ONE VENT HIGH AND ONE VENT LOW.
5.
COORDINATE LOCATION OF "NODE EQUIPMENT" WITH MWR
PRIOR TO START OF WORK.
6.
PRIOR TO PERFORMING FINAL ACCEPTANCE TESTING.
MWR CATV PERSONNEL WILL INSPECT/TEST ALL PROJECTS
ON USFK INSTALLATIONS FOR QUALITY ASSURANCE.
MATERIAL AND PASSIVE DEVICES TO BE USED MUST BE
COORDINATION WITH MWR CATV ON THE TYPE OF CABLE10.
9.
C-COR LINE EXTENDER, DIRECTIONAL COUPLERS, SPLITTERS,
AND TAP-OFF'S ARE TO BE 2WAY AND OPERATE IN THE
CONTRACTORS WILL COORDINATE WITH MWR CATV 30 DAYS 8.
7.
RANGE FROM 5 TO 860MHZ, RETURN PATH 5-42MHZ,
TO INCLUDE ALL ATTENUATION'S TO COMPENSATE FOR
dbMV LEVELS.
ACCEPTANCE INSPECTION.
RESULTS WILL BE RECORDED AND AVAILABLE AT THE FINAL
AGREED UPON BY MWR CATV, CONTRACTOR, AND ANY
ENGINEERS, KORO, DPW PRIOR TO ORDERING.
QUALITY ASSURANCE BRANCH PERSONNEL i.e. CORPS OF
S S
11/U QUAD SHIELDED
COAXIAL CABLE RG
IN 27C
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
E-11
CATV SYSTEM DIAGRAM
NOT TO SCALE
TV
204 204
TV TVTV
TVTV
104104
TV
203 203
TV
TV
206 206
TV TVTV
TVTV
106206
TV
105 105
TV
TV
11/U QUAD SHIELDED
COAXIAL CABLE RG
IN 27C
209 209 209
SYSTEM DIAGRAM
CATV SYSTEM DIAGRAM & TELEPHONE
TO BE TERMINATED AT "TELEPHONE CABINET"
1-4PAIR, #24AWG, CAT-6, TEL WIRE IN 16C
ROOF
2nd FL.
105 105
G
1st FL.
SINGLE CAT-6, MODULAR JACK
8-PIN(RJ-45 TYPE),
WITH COVER PLATE & LUG
(TYPICAL)
#6 "BC" IN 21C
GROUNDING BUSBAR
CONN TO
OF REMOVED EXIST TEL. CABINET
NEMA 1 ENCL AT THE SAME LOCATION
UNPROTECTED TERMINAL BLOCK (4-100PAIR)
PROTECTED TERMINAL BLOCK (1-25PAIR) &
CABINET "TTC" (762mmWx610mmHx152mmD)
TTC
NOT TO SCALE
TELEPHONE SYSTEM DIAGRAM
MAIN PANELBOARD "M"
FLUSH MOUNTED TELEPHONE
IN SPRINKLER RM 109 (TYPICAL)
209203202
207204203202
104104104
103102101
106 106
201 205 205
206 206
,TMGB, RECEPTACLE AND ACCESSORIES
OF TELEPHONE SYSTEM FOR APPROVAL
CONTRACTOR SHALL SUBMIT SHOP DRAWING
L1-20
SSURGE SUPPRESSION TYPE DUPLEX
RECEPTACLE, 2P-3W-20A-125VAC,
TMGB
EXIST 1-25 PAIR #24 AWG IN 103mm dia C.
REPAIR BUILDING S-2369
CAMP CASEYTAK, YS
131607
EXIST 1-25 PAIR #24 AWG IN NEW 103mm dia C.