Drawing_files___141384___MECH_2.pdf
PDF 10 MB Posted
- Attached to
- Repair bathrooms in various buildings, Cp Casey
- Solicitation number
- W91QVN17R0051
About this file
Drawing_Mech2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W91QVN17R0051_Released.docx | DOCX document | |
| Drawing_files___141384___ARCH.pdf | ||
| Drawing_files___141384___MECH_1.pdf | ||
| Submittal_Register___141384.xls | XLS spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-11
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-1146, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
54 20.25 115/1/60 1
E Q U I P M E N T S C H E D U L E
(INCH)
M11
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 53)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
950 17.2WATTS 3 ISOLATION KIT3
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-1146, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 54)
DETERIORATED SHOWERHEADS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-12
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-1147, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CMF)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
44 120 20.25 1,400 125WATTS 115/1/60 1
E Q U I P M E N T S C H E D U L E
(INCH)
M12
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 44)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
3 ISOLATION KIT3
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-1147, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 44)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-13
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-1834, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
44 20.25 15WATTS 115/1/60 1
E Q U I P M E N T S C H E D U L E
(INCH)
M13
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 44)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
900 3 ISOLATION KIT3
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-1834, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 44)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-14
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-1844, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
35 20.25 15WATTS 115/1/60 1
E Q U I P M E N T S C H E D U L E
(INCH)
M14
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 35)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
900 3 ISOLATION KIT3
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-1844, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 35)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-15
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-1854, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
E Q U I P M E N T S C H E D U L E
(TYP OF 100)
DETERIORATED REGISTERS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
M15
1.
NOTES:
2.
OF EXHAUST REGISTERS IN BATHROOM(TYP)
IN BATHROOM(TYP).
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION AND SIZE
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST EXHAUST REGISTERS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-1854, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 100)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-16
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-2024, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
23 20.25 115/1/60 1
E Q U I P M E N T S C H E D U L E
M16
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 23)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
(TYP OF 23)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
(INCH)
13.2WATTS 3 3 ISOLATION KIT
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-2024, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 23)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-17
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-2025, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
23 20.25 115/1/60 1
E Q U I P M E N T S C H E D U L E
(INCH)
M17
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 23)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
850 13.2WATTS 3 ISOLATION KIT3
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-2025, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 23)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-18
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-2218, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
E Q U I P M E N T S C H E D U L E
(TYP OF 100)
DETERIORATED REGISTERS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
M18
1.
NOTES:
2.
OF EXHAUST REGISTERS IN BATHROOM(TYP)
IN BATHROOM(TYP).
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION AND SIZE
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST EXHAUST REGISTERS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-2218, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 100)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-19
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-2361, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O N
ITEM
Q' TY D E S C R I P T I O N
ITEM
AIRJET SHOWERHEAD, HAND-HELD TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : WHITE, SIZE : 73mmDIA. X 165mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
44 20.25 15WATTS 115/1/60 1
E Q U I P M E N T S C H E D U L E
(INCH)
M19
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 44)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
3 ISOLATION KIT3
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-2361, CP CASEY, EQUIPMENT
(TYP OF 44)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AS SHOWN
M-20
MECHANICAL
CHONG,ST
CAMP CASEY
BLDG# S-2607, CP CASEY
NOT TO SCALE
Q' TY D E S C R I P T I O NQ' TY D E S C R I P T I O NITEM
AIRJET SHOWERHEAD, FIXED MOUNT TYPE
JETCORE(2.7) AND AIR-HOLE FOR AIR-INTAKE
SURFACE(COLOR & PLATE) : BLACK, SIZE : 73mmDIA. X 135mmL
MATERIAL : ABS, PELD, RUBBER MATERIAL : EPDM
WATER FLOW RATE AT 80PSI : 1.7GPM
ADJUSTABLE WATER FLOW WITH JETCORE
AIR-INTAKE FROM AIR-HOLE INCREASE WATER SHOOT
EF
E Q U I P M E N T S C H E D U L E
DISCONNECT SWITCH1
NOTE :
REMARKSVOLT/PH/HZHP
RPM
ESP FAN MOTOR
(CFM)
AIR CAP
TYPESERVICE
FANS
Q'TYITEM NO
EF
CEILING GRILLE
BATH RM AREA
CEILING MOUNTED DIRECT DRIVE
CENTRIFUGAL FAN
44 20.25 15WATTS 115/1/60 160
(INCH)
M20
1.
NOTES:
2.
OF EXHAUST FANS IN BATHROOMS(TYP)
IN BATHROOM(TYP).
(TYP OF 44)
DETERIORATED EXHAUST FANS WITH NEW.
REPAIR BY REPLACEMENT OF EXISTING
3 3 ISOLATION KIT
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING CEILLING, DUCT, ETC. TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION(TYP).
THE CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND CAPACITY
THE CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR EXHAUST FANS
RESTORE CEILING GYMSUM BOARD(TYP)
VARIOUS BLDGS
REPAIR BATHROOMS,
141384
SCHEDULE AND NOTES
BLDG# S-2607, CP CASEY, EQUIPMENT
OR APPROVED EQUAL
REFER TO "MODEL NO KSAJ-100, KOSDO INC(KOREA WATER MANAGEMENT)
(TYP OF 44)
| Repair exhaust fan, shower head(FINAL)-M1-1 |
| Repair exhaust fan, shower head(FINAL)-M2-1 |
| Repair exhaust fan, shower head(FINAL)-M3-1 |
| Repair exhaust fan, shower head(FINAL)-M4-1 |
| Repair exhaust fan, shower head(FINAL)-M5-1 |
| Repair exhaust fan, shower head(FINAL)-M6-1 |
| Repair exhaust fan, shower head(FINAL)-M7-1 |
| Repair exhaust fan, shower head(FINAL)-M8-1 |
| Repair exhaust fan, shower head(FINAL)-M9-1 |
| Repair exhaust fan, shower head(FINAL)-M10-1 |
| Repair exhaust fan, shower head(FINAL)-M11-1 |
| Repair exhaust fan, shower head(FINAL)-M12-1 |
| Repair exhaust fan, shower head(FINAL)-M13-1 |
| Repair exhaust fan, shower head(FINAL)-M14-1 |
| Repair exhaust fan, shower head(FINAL)-M15-1 |
| Repair exhaust fan, shower head(FINAL)-M16-1 |
| Repair exhaust fan, shower head(FINAL)-M17-1 |
| Repair exhaust fan, shower head(FINAL)-M18-1 |
| Repair exhaust fan, shower head(FINAL)-M19-1 |
| Repair exhaust fan, shower head(FINAL)-M20-1 |
File details come from the government source that posted it. Updated .