Drawings.pdf
PDF 2 MB Posted
- Solicitation number
- W912WJ18B0019
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Abstract.pdf | ||
| W912WJ18B0019-Amendment_0001.pdf | ||
| SPECS.pdf | ||
| W912WJ18B0019-Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
F
T H
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B 9 7
OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL
APPROVED FOR TECHNICAL ADEQUACY BY:
TECHNICAL LEAD ENGINEER DATE
DATE
DATE
DATE
DATE
APPROVED BY:
APPROVAL RECOMMENDED BY:
REVIEWED BY:
CHIEF, GEOTECHNICAL/WATER RESOURCES BRANCH
REVIEWED BY:
CHIEF, DESIGN BRANCH
ELECTRICAL SITE PLAN
DESIGN FILESHEET NO.
G-001
INDEX TO DRAWINGS
SHEET TITLE
scope of their employment as required by ER 1110-1-8152.
and registration designations of individuals appear on these project documents, within the
This project was designed by the U.S. Army Corps of Engineers. The initials or signatures
CHIEF, ENGINEERING DIVISION
THA-WV-121_G-001.DGN
SOUTHBRIDGE, MASSACHUSETTS
WESTVILLE LAKE DAM
ELECTRICAL DISTRIBUTION SYSTEM UPGRADE
J
C L
IN
E
D
H A
S S
E T
T
A N
S I
D
G-001
:1
CHIEF, GEO-ENVIRONMENTAL ENGINEERING BRANCH
DATE
APPROVAL RECOMMENDED BY:
CHIEF, TECHNICAL SUPPORT BRANCH/DEPUTY CHIEF ENG DIV
MASS.
CONN.
THOMPSON
A
N of Engineers
US Army Corps
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
New England District
COVER SHEET AND INDEX TO DRAWINGS
THA-WV-121_E-001.DGNE-001
E-101 THA-WV-121_E-101.DGN
THA-WV-121_E-103.DGN
THA-WV-121_E-601.DGN
LOCATION
PROJECT
R O
A D
R I
E V
R
KEL
L
Y R D.
S O
U
R
A D
M
A S
H
A P
A
UG
R O
D A
M A S
HA
PA
UG
B R
E A
K N
E K
C
DAOR
D A
O R
S O
U T
H
D E
N N
IS
O N
WESTVILLE
D R
I V
E
S T
R E
E T
DAM
WESTVILLE
W L
L A
E C
R O
A D
R O
A D
S H
E P
A R
D
131 P A
R K R
D
F A
IR
V
IE
W
F
IS
K H
IL
L R
O A
D
SO
U
TH
BR
ID
G E R
O
AD
RESERVOIR
QUABBIN
WARE
SPENCER
WORCESTER
16131
PROJECT
LOCATION
DANIELSON
PUTNAM
MECHANICSVILLE
WOODSTOCK
PROVIDENCE
R.I.
MASS.
EAST BRIMFIELD
FISKDALE
STURBRIDGE
SHEET NO.
SHEET TITLEDRAWING NUMBER
TH-1-1692
TH-1-1661
TH-1-166526
INDEX TO INFORMATION DRAWINGS
E-103
VICINITY MAP
NOT TO SCALE NOT TO SCALE
LOCATION PLAN
4 THA-WV-121_E-102.DGNE-102
7 THA-WV-121_E-602.DGNE-602 ELECTRICAL ONE LINE RISER DIAGRAM
TH-1-1689
TH-1-1690
TH-1-1687
SPILLWAY AND OUTLET WORKS - PROFILE AND WEIR SECTIONS
OUTLET WORKS
ARRANGEMENT OF EQUIPMENT
ELECTRICAL DISTRIBUTION PLANS DETAILS
CONTROL HOUSE AND SPILLWAY ELECTRICAL PLANS
UTILITY BUILDING - PLUMBING, HEATING AND ELECTRICAL
UTILITY BUILDING AND STORAGE GARAGE FLOOR PLANS EXISTING AND NEW CONDITIONS
GATEHOUSE FLOOR PLAN EXISTING AND NEW CONDITIONS
C O
V E
R S
H E
E T A
N D I
N D
E X T
O D
R A
W
IN
G S
34 TH-1-1673 CONTROL HOUSE - STEEL REINFORCEMENT, ROOF SLAB & OPERATING FLOOR SLAB
J U
L Y
JULY 2018
ELECTRICAL NOTES, LEGEND, ABBREVIATIONS AND GROUNDING DETAIL
E-601 PANEL BOARD SCHEDULES
W912WJ18B0019
M J
U R
C
IC
D
N G
U Y
E N
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B
G
PANEL
PP-UBDS-1
SWITCH
TRANSFER
GENERATOR
CB-1
BREAKER
CIRCUIT
ENTRANCE
SERVICE
TRANSFORMER
NOTES:
1. NEUTRAL SHALL ONLY BE GROUNDED AT THE NEW 225A CIRCUIT
BREAKER CB-1.
2. THE CONTRACTOR SHALL MODIFY THE EXISTING GROUNDING SCHEME TO
UNDING CONDUCTORS, AND THE PANEL ENCLOSURE.
3. THE CONTRACTOR SHALL INSURE THAT THE GATEHOUSE GROUNDING
ELECTRODE IS CONNECTED TO THE GROUND BUS ONLY AND THE NEW
FEEDER EQUIPMENT GROUND CONDUCTOR.
N
G
DS-2
DISC. SW. PANEL
PP-SG
PANEL
PP-GH
NN N
G GG
N
G
N
AMPERES
CONDUIT
CIRCUIT
CIRCUIT BREAKER
BUILDING
EXHAUST FAN
EMERGENCY
ELECTRICAL METALLIC TUBING
GROUND OR GROUNDING
FULL LOAD AMPERES
THOUSAND CIRCULAR MILS
GALVANIZED RIGID METALLIC CONDUIT
kcmil
FLA
FT
GRMC
GND,G
FEET
EM
EMT
EF
CB
CKT
BATT
C
BLDG
A
QUANTITY
SYMMETRICAL
POLYVINYL CHLORIDE
RIGID METAL CONDUIT
TRANSFORMER
UNLESS OTHERWISE NOTED
UNDERWRITERS LABORATORIES
XFMR
W
V
WIRE
VOLT
UL
U.O.N.
SP
SYM
SPARE
PWR
QTY
PVC
RMC
POWER
KILOWATTS
LIGHTING
MISCELLANEOUS
MAIN LUGS ONLY
KILOVOLT AMPERES
MAIN CIRCUIT BREAKER
ASSOCIATION
NOT TO SCALE
NATIONAL ELECTRICAL
NATIONAL ELECTRIC CODE
MANUFACTURES ASSOCIATION
NATIONAL FIRE PROTECTION
NTS
PNL PANEL
NEC
NEMA
NFPA
MCB
MLO
MISC
kW kVA
LTG
GENERAL ABBREVIATIONS
CABINET UNIT HEATERCUH
EXISTING UTILITY POLE TO REMAIN
E
E
EQUIPMENT LEGEND
DISCONNECT SWITCH (UNFUSED)
DISCONNECT SWITCH (FUSED)
PANELBOARD
SYSTEM GROUND OR EQUIPMENT GROUND
PANEL
SPD
SUPPRESSER)
SURGE PROTECTIVE DEVICE (TRANSIENT VOLTAGE SURGE
PB PULL BOX
GENERAL NOTES:
WIRING DEVICES LEGEND
XL
XD
XN
XR
XM
RESPONSIBLE FOR MAINTAINING CIRCUITRY TO DEVICES
PANELBOARD AS SPARE. CONTRACTOR SHALL BE
CONDUIT AS REQUIRED SO AS TO PROVIDE A
COMPLETE OPERATIONAL INSTALLATION.
TO BE REMOVED. CUT BACK AND MAKE SAFE ALL
EQUIPMENT TO BE REMOVED AND REPLACED WITH NEW.
"XL" ADJACENT TO EQUIPMENT DENOTES RELOCATED
EXISTING AT NEW LOCATION
UNAFFECTED BY DEMOLITION.
"XD" ADJACENT TO EQUIPMENT DENOTES EXISTING
"XR" ADJACENT TO EQUIPMENT DENOTES EXISTING
"XN" ADJACENT TO EQUIPMENT DENOTES EXISTING
"XM" ADJACENT TO EQUIPMENT DENOTES EXISTING
SYMBOLS OUT OF FUNCTION DENOTE EXISTING
TO BE RELOCATED AS SHOWN. CUT BACK AND/OR
EXTEND EXISTING BRANCH CIRCUIT WIRING AND
EQUIPMENT TO REMAIN.
EXISTING EQUIPMENT LEGEND
IN EXISTING LOCATION.
TO BE REMOVED, STORED, CLEANED AND REINSTALLED
"XS" ADJACENT TO EQUIPMENT DENOTES EXISTING
XS
ASSOCIATED BRANCH CIRCUIT WIRING AND CONDUIT
BACK TO POWER SOURCE AND LABEL BREAKER IN
EMH-1
CMH-1
COMMUNICATIONS MANHOLE. NUMERAL INDICATES
MANHOLE NUMBER
ELECTRIC MANHOLE. NUMERAL INDICATES MANHOLE
NUMBER
J
C L
IN
E
D
H A
S S
E T
T
A N
S I
D
E-001
:1
M J
U R
C
IC
BATTERY
ELECTRIC UNDERGROUND UTILITY LINE
ELECTRIC OVERHEAD UTILITY LINE
COMM COMMUNICATION OVERHEAD UTILITY LINE
COMM COMMUNICATION UNDERGROUND UTILITY LINE
ELEVATIONEL.
J U
L Y
RV
CHARACTERISTICS.
REFER TO SPECIFICATIONS FOR ALL OTHER
PROVIDE (1) 5-20R GFI RECEPTACLES.
30A-1P AND 20A-1P.
CIRCUIT BREAKER PROVISIONS SHALL BE 50A-2P,
125 CONTINUOS AMPERE ,NEMA 3R ENCLOSURE
RV POWER CONNECTION 240V, 1 PHASE 60Hz, ATS AUTOMATIC TRANSFER SWITCH
DIST DISTRIBUTION
DP DISTRIBUTION PANEL
RECREATIONAL VEHICLERV
DS
A1
NOT TO SCALE
A N
D G
R O
U N
D
IN
G D
E T
A
IL
E L E
C T
R
IC
A L N
O T
E S L E
G E
N D
A B
B R
E V
IA
T
IO
N S
GROUNDING ELECTRODE SYSTEM DETAIL
LINE TYPE LEGEND
COR CONTRACTING OFFICER'S REPRESENTATIVE
SPD
GRS
UNDERGROUND OR UNDERGRADEUG
TYP. TYPICAL
MIN. MINIMUM
GALVANIZED RIGID STEEL
SURGE PROTECTIVE DEVICE
G GROUND
N NEGATIVE
DISCONNECT SWITCH
AWG AMERICAN WIRE GAUGE
125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX RECEPTACLE.
D
N G
U Y
E N
M
J JUNCTION BOX
ELECTRIC MOTOR
$3
SINGLE POLE TOGGLE SWITCH
THREE WAY TOGGLE SWITCH
GFCI GROUND FAULT CIRCUIT INTERRUPTER
INFORMATION TECHNOLOGYIT
NP NAME PLATE
G.
F.
E.
D.
C.
B.
A.
COMPLETE AND PROPER ELECTRICAL INSTALLATION. THIS WORK SHALL INCLUDE:
INCLUDED IN THE CONTRACT AS REQUIRED TO PROVIDE AND MAINTAIN A
ALL NECESSARY ADDITIONS AND ALTERATIONS TO EXISTING WORK SHALL BE11.
INSTALLATIONS.
FOR EASE OF DISCONNECTING WITH MINIMUM OF INTERFERENCE WITH OTHER
OF EQUIPMENT COMPONENTS AS MUCH AS PRACTICAL. CONNECT THE EQUIPMENT
ELECTRICAL EQUIPMENT TO FACILITATE MAINTENANCE, REPAIR AND REPLACEMENT
AND OVERHEAD EQUIPMENT TO PROVIDE MAXIMUM HEADROOM POSSIBLE. INSTALL
WHERE MOUNTING HEIGHTS ARE NOT DETAILED, INSTALL ELECTRICAL SERVICES10.
ONE BOX WITH A SINGLE COVER PLATE.
WHENEVER SIMILAR DEVICES ARE SHOWN TOGETHER, THEY SHALL BE GANGED IN9.
FIRE RESISTANT CONSTRUCTION.
SIDE WALL HORIZONTAL SPACING COMPLY WITH STATE BUILDING CODE REGARDING
ASSEMBLIES SUCH THAT AREA OF BOX PER WALL AREA AND OUTLET ON OPPOSITE
COORDINATE EXACT LOCATION OF ALL BOXES IN TWO HOUR OR LESS RATED
SHALL BE MOUNTED 8" APART ON CENTER HORIZONTALLY. CONTRACTOR SHALL
RECEPTACLES AND TELECOMMUNICATIONS OUTLETS SHOWN ADJACENT ON DRAWINGS8.
THREE CIRCUITS PER CONDUIT HOME RUN.
RECEPTACLE CIRCUITS ONLY MAY BE EXEMPTED, LIMITED TO NOT MORE THAN
SHALL NOT BE PERMITTED WITHOUT PRIOR WRITTEN APPROVAL. LIGHTING AND
CONSOLIDATION OF INDIVIDUAL CONDUIT HOME RUNS SHOWN ON THE DRAWINGS7.
FIXTURE OR EQUIPMENT UNLESS OTHERWISE NOTED.
MOUNTING HEIGHTS OF ALL DEVICES ARE TO CENTER OF DEVICES, OUTLET,6.
NEC 250.122.
ALL CIRCUITS TO BE RUN WITH GREEN GROUNDING CONDUCTOR SIZED PER5.
REQUIRING A NEUTRAL I.E. NO SHARED NEUTRAL.
SEPARATE NEUTRAL CONDUCTORS SHALL BE RUN WITH ALL BRANCH CIRCUITS4.
TYPE OF SYSTEM, PANEL AND CIRCUIT NUMBER.
FOR ALL ALTERED PANELS. LABEL AND IDENTIFY ALL JUNCTION BOXES WITH
EQUIPMENT SERVED, ROOM NUMBERS, SPARE OR SPACE. UPDATE DIRECTORIES
ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING3.
COUNTERS, ETC.
COORDINATE ALL DEVICE LOCATIONS WITH ACTUAL DOOR SWINGS, CABINETS,
DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT.2.
CONTRACTING OFFICERS REPRESENTATIVE.
SHALL BE SCHEDULED IN ACCORDANCE WITH THE SPECIFICATIONS AND THE
ELECTRIC SHUT-DOWNS SHALL BE AS MINIMAL IN DURATION AS POSSIBLE. WORK
TO MINIMIZE DISRUPTION TO THE FACILITY.
ALL WORK FOR THIS PROJECT SHALL BE CAREFULLY COORDINATED1.
WORK OF THIS CONTRACT.
RESTORED TO ITS ORIGINAL AND OPERATING CONDITION AFTER THE
VERIFICATION THAT THE EXISTING EQUIPMENT OR SYSTEM SHALL BE I.
H. REMOVAL AND DISPOSAL OF ALL EQUIPMENT INDICATED TO BE DEMOLISHED.
AND ACCESSIBLE LOCATIONS.
REMOVAL OF UNUSED CONDUIT FROM CEILINGS, EXPOSED AREAS
IN FLOORS OR WALLS.
ABANDONMENT IN PLACE OF UNUSED CONDUIT WHERE CONCEALED
REMOVAL AND DISPOSAL OF UNUSED CONDUIT OR CONDUCTORS.
CLEAN AND IN WORKING ORDER.
TO THE CONTRACTING OFFICER’S REPRESENTATIVE SHALL BE
VERIFICATION THAT EQUIPMENT THAT IS TO BE TURNED OVER THE
RELOCATION OF PIPING AND DUCTWORK TO ALLOW FOR WORK.
TEMPORARY WORK.
ALLOW FOR CONTINUED OPERATION DURING THE WORK, TO INCLUDE
DISCONNECTION/RECONNECTION/REINSTALLATION OF EQUIPMENT TO
RELOCATION OF EQUIPMENT TO ALLOW FOR WORK.
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B
BUILDING
UTILITY
STORAGE GARAGE
GATE
HOUSE
M A
R J O
R
IE
L
A N
E
SEE NOTE 6
TO REMAIN
GRID UTILITY POLE
EXISTING NATIONAL
Q U
IN
E B
A U
G R
IV
E
R
F L
O W
MANHOLE CMH-1 TO REMAIN
EXISTING COMMUNICATIONS
EMH-1 TO REMAIN
EXISTING MANHOLE
SEE NOTES 2 AND 3
MANHOLE EMH-2
EXISTING ELECTRICAL
MANHOLE CMH-2 TO REMAIN
EXISTING COMMUNICATIONS
DUCTBANK TO REMAIN
EXISTING UNDERGROUND
DUCTBANK TO REMAIN
EXISTING UNDERGROUND
SEE NOTE 5
E
FROM UTILITY
INCOMING POWER
A1
30' 60'0SCALE: 1" = 30'
ELECTRICAL SITE PLAN
J
C L
IN
E
D
H A
S S
E T
T
A N
S I
D
E-101
E L E
C T
R
IC
A L S
IT
E P
L A
N
:1
M J
U R
C
IC
J U
L Y
D
N G
U Y
E N
REFERENCE WORK REQUEST NUMBER 2599-7422.
ENTRANCE WORK CALL NATIONAL GRID AT 800-375-7405 AND
THREE (3) 10KVA TRANSFORMERS TO REMAIN. FOR SERVICE
6. EXISTING NATIONAL GRID UTILITY POLE NUMBER 17-1 AND
SHEET E-001 FOR FURTHER INFORMATION.
REUSE EXISTING PEDESTAL. REFER TO EQUIPMENT LEGEND ON
REPLACED WITH NEW RV POWER CONNECTION.
5. EXISTING RV POWER CONNECTION PEDESTAL MOUNTED TO BE
AND STORAGE GARAGE FROM THE UTILITY BUILDING.
CONTRACTOR SHALL PROVIDE NEW FEEDERS TO GATE HOUSE
4. EXISTING UNDERGROUND DUCTBANK TO REMAIN. ELECTRICAL
AND COMPLETION OF PULLING OF CONDUCTORS.
TO SCHEDULE POWER SHUT DOWN FOR FINAL CONNECTIONS
STAFF OF THE WESTVILLE LAKE DAM 72 HOURS IN ADVANCE
3. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE
2. FOR ELECTRICAL RISER DIAGRAM REFER TO SHEET E-602.
1. FOR LEGEND AND GENERAL NOTES SEE SHEET E-001.
NOTES:
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B
S S S3 3
DN.
OPEN HATCH
SS
OPERATING ROOM FLOOR OBSERVATION DECK EL. 587.50
12"X12"X6" DEEP TELEPHONE CABINET
UP TO FLOODLIGHT #1
NP 8 FLOODLIGHT PB. STA.
SWITCH NP6
VG-4
NP7 - FLOODLIGHT
4#12
TELEPHONE OUTLET
BATTERY CHARGER
2"C-4#2
HEATER
SERVICE SWITCH NP 5,5A & 5B
XD
XD
CEILING LIGHTS
CANOPY FIXTURE
2" C - 4#2
TO DIESEL BATTERY CHARGER
EXISTING EMERGENCY
ELECTRICAL GENERATOR
TO REMAIN
CAP 6" ABOVE FLOOR
TWO 1 1/2" CONDUIT
DEMOLISHED
PANEL TO BE
(DP) NP4 POWER
ORIGINAL DIST. PANEL
FOR RELATED WORK
REFER TO DRAWING E-602
4" C-4# 4/0 TO PANEL (DP) NP4
4" FIBER
4" TELEPHONE CONDUIT 8#14 IRON PULL WIRE
4" C-1- 3/C #12 FLOODLIGHT CONTROL
S S S3 3
DN.
OPEN HATCH
SS
OPERATING ROOM FLOOR OBSERVATION DECK EL. 587.50
12"X12"X6" DEEP TELEPHONE CABINET
UP TO FLOODLIGHT #1
NP 8 FLOODLIGHT PB. STA.
NP7 - FLOODLIGHT
4#12
BATTERY CHARGER
DISCONNECT SWITCH DS-2
POWER PANEL PP-GH
CEILING LIGHTS
SEE NOTE 2
4" TELEPHONE CONDUIT 8#14 IRON PULL WIRE
4" FIBER
EXISTING EMERGENCY
ELECTRICAL GENERATOR
TO REMAIN
CANOPY FIXTURE
2" C - 4#2
4" C-1- 3/C #12 FLOODLIGHT CONTROL
SWITCH DS-1
DOUBLE THROW DISCONNECT
FOR RELATED WORK
REFER TO DRAWING E-602
J
C L
IN
E
D
H A
S S
E T
T
A N
S I
D
E-102
G A
T E
H O
U S
E F
L O
O R P
L A
N
:1
C5
N
0 4' 8'2'SCALE: 1/4" = 1'-0"
M J
U R
C
IC
C1
N
0 4' 8'2'SCALE: 1/4" = 1'-0"
EXISTING CONDITIONS GATE HOUSE FLOOR PLAN NEW CONDITIONS GATE HOUSE FLOOR PLAN
E X
IS
T
IN
G A
N D N
E W C
O N
D
IT
IO
N S
NOTES:
J U
L Y
D
N G
U Y
E N
REFER TO DRAWING E-602 FOR FURTHER INFORMATION.
CIRCUIT TO BE REPLACED AND POWERED VIA NEW PANEL PP-GH.
3. PANEL TUB AND COVER TO REMAIN. WIRING FROM FIRST DEVICE IN EACH
ORIGINAL CIRCUIT SHALL REMAIN ON SAME CIRCUIT.
REFER TO PANELBOARD SCHEDULE ON DRAWING E-601. REMAINING DEVICES ON
IT IS ON A DEDICATED CIRCUIT. PROVIDE 2#12,1#12GND TO PANEL PP-GH CIRCUIT 24.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW WIRING FOR THIS DEVICE SO THAT
SEE DRAWING E-602 FOR FURTHER INFORMATION ON WORK REQUIREMENTS.
1. THIS DRAWING SHOWS GENERAL LOCATIONS OF EXISTING AND NEW EQUIPMENT.
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B
J M
M
M
M
M
LTG. PANEL - NP 12
E2-IT DUCT LINE
CAP AND TAG
STUB 6" ABOVE FLOOR
4" TEL. CONDUIT
CONTROL HOUSE SWITCH NP-11
MAIN SERVICE SWITCH NP-18
M
2" C-4#2
NOTE 2
XD
XD
XD
RV
XN
XD
RV
XN
XD
XD
XD
XD
HEATER ROOM
OFFICE
GARAGE
RESTROOM
SHOWER WITH TUB
STORAGE ROOM
MEETING ROOM
S
C
SSS
S
BURNER
OIL
S
S
S
TO EMH-1
TO CMH-1
NP-10
UTILITY BUILDING SERVICE SWITCH
S
NP-15
NP-14
NP-16
FLOODLIGHT CONTROL Pb. NP-13
COMPRESSOR
TO REMAIN
EXISTING PULL BOX
SEE NOTE 1
HEATER ROOM
OFFICE
GARAGE
J M
M
M
M
M
E2-IT DUCT LINE
RV
RV
RESTROOM
SHOWER WITH TUB
CB-1
RATED CIRCUIT BREAKER
NEW SERVICE ENTRANCE
MEETING ROOM
STORAGE ROOM
S
FLOODLIGHT CONTROL Pb. NP-13
S S
C
S
BURNER
OIL
NP-15
NP-14
NP-16
S
S
TO EMH-1
TO CMH-1
COMPRESSOR
S
S
NEW POWER PANEL PP-UB
EXISTING PULL BOX
GARAGE DOOR GARAGE DOOR GARAGE DOOR
FOR FURTHER INFORMATION
REFER TO DRAWING E-602
GENERATOR PANEL TO BE DEMOLISHED
FOR FURTHER INFORMATION
REFER TO DRAWING E-602
GENERATOR PANEL TO BE DEMOLISHED
GARAGE DOOR GARAGE DOOR GARAGE DOOR
FOR FURTHER INFORMATION
REFER TO DRAWING E-602
NEW POWER PANEL PP-SG
J
C L
IN
E
D
H A
S S
E T
T
M J
U R
C
IC
A N
S I
D
E-103
:1
E1
N
SCALE: 1/4" = 1' - 0"
E6
N
SCALE: 1/4" = 1' - 0"
A1
N
SCALE: 1/4" = 1' - 0"
A6
N
SCALE: 1/4" = 1' - 0"
EXISTING CONDITIONS UTILITY BUILDING FLOOR PLAN
EXISTING CONDITIONS STORAGE GARAGE FLOOR PLAN
NEW CONDITIONS UTILITY BUILDING FLOOR PLAN
NEW CONDITIONS STORAGE GARAGE FLOOR PLAN
S T
O R
A G
E G
A R
A G
E F
L O
O R P
L A
N S
NOTES:
E X
IS
T
IN
G A
N D N
E W C
O N
D
IT
IO
N S
J U
L Y
U T
IL
IT
Y B
U
IL
D
IN
G A
N D
2. THIS SHEET SHOWS GENERAL LOCATIONS OF EXISTING AND NEW EQUIPMENT.
1. SEE SHEET E-602 FOR FURTHER INFORMATION AND WORK REQUIREMENTS.
D
N G
U Y
E N
NOTES:
2. REFER TO EXISTING POWER RISER DIAGRAM ON DRAWING E-602 FOR FURTHER INFORMATION.
1. REFER TO ELECTRICAL SITE PLAN E-101 FOR ELECTRICAL SERVICE INFORMATION.
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B
TRIP
BREAKER
PANELBOARD SCHEDULE PP-GH
DESCRIPTION
DEHUMID & RECEPTS LEVEL 3
POLE
EXTERIOR LIGHTS
DESCRIPTION
MOUNTING: SURFACE
LOAD SUB-TOTALS: 26.8kVA
OPERATING LEVEL RECEPTS
LIGHTING LEVEL 550
LIGHTING OPERATING GALLERY
BATTERY CHARGER
LIGHTING OPERATING LEVEL
AIC RATING: 10K
LIGHTING ELEV 572.17
NO.
CKT.
A
B
C
A
B
C
A
B
C
A
B
C
NO.
CKT.
TRIP
BREAKER
POLE
kVA
LOAD
kVA
LOAD
0.5
1.0
1.0
15.6 10.5
RECEPTS ELEV. 550 OPERATING GALLERY
GATE HOIST #3
0.6
0.2
0.6
0.4
BUSSING: COPPER
MAINS: 100A MCB GROUND BUS: EQUIPMENT
TUB: SINGLE
25 26
27 28
29 30
0.6
1.0
0.5
0.5
5.6 0.4
5.6
201 -
202 -
LIGHTING TUNNEL
GATE HOIST #1
RECEPTS OPERATING LEVEL SOUTH&WEST WALL
SPARE
SPARE
1.0 201FLOOD LIGHTS
- 201SPARE
- 201SPARE
WIREWIRE
ELEV 530 RECEPTS AND EBU
OIL BURNER
SPARE
201 .70
202 -
LIGHTING OPERATING GALLERY
GATE HOIST #2 4035.6
201 0.2 12
0.5 201
TRIP
BREAKER
PANELBOARD SCHEDULE PP-UB
DESCRIPTION
SEWER PUMP
POLE
FRIDGE
DESCRIPTION
MOUNTING: SURFACE
LOAD SUB-TOTALS: 69.4KVA
RANGE
OUTSIDE PHOTOEYE ON LIGHT
MISC LIGHTS
AIC RATING: 10 K
GARAGE DOOR OPENER
NO.
CKT.
A
B
C
A
B
C
A
B
C
A
B
C
NO.
CKT.
TRIP
BREAKER
POLE
kVA
LOAD
kVA
LOAD
0.5
1.2
32.4 37.0
FAN LIGHT
RECEPTS KITCHEN GFCI
1.0
0.2
0.5
0.6
BUSSING: COPPER
MAINS: 175A MCB GROUND BUS: EQUIPMENT
TUB: SINGLE
25 26
27 28
29 30
6.25
6.6
0.4
0.4
RECEPTS
SPARE0.2 201PLUG ON BACK WALL
5.0 302DRYER
WIREWIRE
RECEPTS KITCHEN GFCI
RV PEDESTAL #1
SPARE
502 8.3
201 -
RV PEDESTAL #2
WATER HEATER 1.2
X
12 8.3 502
GARAGE LIGHTS 0.6
PANEL GFCI 1.0
GARAGE GFCI AND ALARM 0.5
GFCI ABOVE GARAGE DOOR 0.2
32A
B
C
37 38
39 40
603 22.0 PANEL STORAGE GARAGE PP-SG201SPARE -
SPARE
- 201SPARE
A/C 1522.5
201 - SPARE-SHOWER AREA GFCI 2010.2
A
B
C
A
B
201 0.6 LIVING ROOM LIGHTS AND PLUGS12
201 1.0 BOILER12
201 SPARE- -
SPARE- -
TRIP
BREAKER
PANELBOARD SCHEDULE PP-SG
DESCRIPTION
WELDER
POLE
TABLE SAW
DESCRIPTION
MOUNTING: SURFACE
LOAD SUB-TOTALS: 37.6KVA
HEATER TOOL ROOM
RECEPTACLE DOWN STAIRS
AIC RATING: 10 K
NO.
CKT.
A
B
C
A
B
C
A
B
C
A
B
C
NO.
CKT.
TRIP
BREAKER
POLE
kVA
LOAD
kVA
LOAD
3.0
5.0
20.6 17.0
AIR COMPRESSOR
BAY 3 LIGHTS
0.4
BUSSING: COPPER
MAINS: 60A MCB GROUND BUS: EQUIPMENT
TUB: SINGLE
25 26
27 28
29 30
14.0
3.0
1.6
0.8
WIREWIRE
GARAGE DOOR
TOOL ROOM OUTLETS
SPARE
201 1.0
201 -
BAY 3 220VOLT RECEPTACLE
X
12 3.0 202
FLOOD LIGHT 0.1
- 201SPARE
- 201SPARE
- 201SPARE
A
B
C
201 0.8 DOWNSTAIRS LIGHTS12
201 0.2 FUEL PUMP EMERGENCY LIGHTS12
EXHAUST FAN DAMPER 0.5 201
0.5FURNACE
0.5TOOL ROOM LIGHTS
1.0OUTLETS DOWNSTAIRS
1.0OUTLETS BAY 3 BAY 2 RECEPTS201 - 12
201 SPARE- 12
SPARE- 12
41 42- 201- C
A
B
C
RECEPTACLE OPERATING LEVEL WEST WALL,
SOUTH OF EXISTING ELEC PANEL
D
H A
S S
E T
T
A N
S I
D
E-601
:1
M J
U R
C
IC
J
C L
IN
E
P A
N E
L B
O A
R D S
C H
E D
U L E
S
J U
L Y
D
N G
U Y
E
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
A -W
V -1
S O
U T
H B
R
ID
G E
M A
S S
A C
H U
S E
T T S
W E
S T
V
IL
L E L
A K
E D
A M
E L E
C T
R
IC
A L D
IS
T R
IB
U T
IO
N S
Y S
T E
M U
P G
R A
D E
SHEET ID
®of Engineers
US Army Corps
W
W J
B
SWITCH
DISCONNECT
ENTRANCE
SERVICE
M
UTILITY COMPANY
METER
SERVICE ENTRANCE
DISCONNECT FOR
STORAGE GARAGE
CIRCUIT BREAKER
ENCLOSED
50A-1POLE
BOX
TAP
GATE TOWER SERVICE SWITCH.
120/208V, 100A-3POLE, FUSED
SWITCH
WIRE TAP BOX
TO REMAIN
SECURITY CONTROL
PANEL. TO REMAIN. SEE
NOTE 6
UTILITY BUILDING
SERVICE SWITCH.
120/208V, 50A-3POLE
FUSED SWITCH
EXISTING
PULL
BOX TO
REMAIN
DEVICE
PROTECTIVE
3 PHASE SURGE
NORMAL POWER PANEL.
42POLES, 120/208V,
3PHASE,100A MCB.
PLUG
CONNECTION FOR
PORTABLE
GENERATOR
CONDUIT
FLEXIBLE
PANEL
POWER
100A-3POLE FUSED
DOUBLE THROW
DISCONNECT SWITCH
60A-3POLE FUSED
DISCONNECT SWITCH.
EMERGENCY FEED TO
UTILITY BUILDING
PULL/TAP
BOX TO
REMAIN
REMOVED
WIREWAY TO BE
6"X6"X6"
EMH-1 EMH-2
2"C-4#2AWG.
4#2AWG TO BE REMOVED.
REFER TO NEW POWER RISER
DIAGRAM BELOW FOR
FURTHER INFORMATION
4" CONDUIT
MAIN ELECTRIC
SERVICE FROM
UTILITY POLE TO
REMAIN. SEE NOTE 9
2" CONDUIT WITH
4-1AWG & 1-8AWG
GND TO STORAGE
GARAGE. SEE NOTE 8
MCB.
1PHASE, 60A
120/208V, 10POLES,
PANEL.
POWER
EMERGENCY
BUILDING
UTILITY
SWITCH IN
DISCONNECT
MAIN SERVICE
2" CONDUIT TO
CONDUIT "LB" FOR CONDUIT
ENTRANCE INTO THE BUILDING
4" EMPTY CONDUIT
TO REMAIN. SEE
NOTE 4
3/4" EMPTY CONDUIT
TO REMAIN. SEE
NOTE 4
POWER
GEN
POWER
UTILITY
2" CONDUIT
EMBEDDED IN
CONCRETE WALL
WITH 4-2AWG.
INTERIOR
UTILITY BUILDING UTILITY BUILDING
EXTERIOR
GATE HOUSESTORAGE
GARAGE
FINISHED FLOORDAM CRESTFINISHED FLOORFINISHED FLOOR FINISHED GRADE
1. ALL EQUIPMENT AND CONDUIT AND WIRES
SHOWN ARE EXISTING TO BE REMOVED
UNLESS NOTED OTHERWISE.
2. EXISTING CONDUITS TO REMAIN SHALL BE
REUSED UNLESS NOTED OTHERWISE.
3. REFER TO PART PLAN FLOOR PLANS FOR
EQUIPMENT LOCATIONS.
4. EXISTING EMPTY CONDUIT SHALL BE
SEALED AND CAPPED IN PLACE.
5. SERVICE CONDUCTORS ENTER THIS
SWITCH THROUGH THE BACK.
6. SECURITY CONTROL PANEL SHALL BE
RELOCATED BY OTHERS PRIOR TO
COMMENCEMENT OF THIS PROJECT.
7. REMOVE EXISTING FEEDER CONDUCTORS.
CUT CONDUIT AT BOTH ENDS 6" ABOVE
FINISHED FLOOR, SEAL AND CAP AT BOTH
ENDS.
8. EXISTING CONDUIT TO REMAIN. REMOVE
EXISTING FEEDER CONDUCTORS,
PROVIDE NEW WORK AS INDICATED ON
"NEW POWER RISER DIAGRAM".
9. EXISTING #2AWG CONDUCTORS SHALL
REMAIN. DISCONNECT AND RECONNECT IN
ASSOCIATION WITH WORK INDICATED ON
"NEW POWER RISER DIAGRAM".
COORDINATE ALL UTILITY WORK WITH
NATIONAL GRID. THE ACCOUNT NUMBER
FOR THIS SITE IS 52981-45002.
10. EXISTING PANEL IS MOUNTED IN FRONT
OF THE ORIGINAL RECESSED BACK BOX
OF THE ORIGINAL POWER PANEL. RETAIN
PANELBOARD TUB AND COVER TO BE
USED AS A PULL BOX. CUT OPENING IN
BACK OF TUB THE SIZE OF THE ORIGINAL
OPENING, DE-BURR AND PROVIDE
CORRUGATED LOOM TUBING AROUND ALL
CUT EDGES. CIRCUITS TO NEW PANEL
SHALL BE SURFACE MOUNTED. REFER TO
NEW ELECTRICAL RISER DIAGRAM BELOW.
COORDINATE CUT OVER WITH COR TO
MINIMIZE POWER OUTAGE.
11. REMOVE EXISTING FEEDER CONDUCTORS.
CUT BACK EXISTING EXPOSED CONDUIT 6"
ABOVE THE FLOOR, SEAL AND CAP.
CAP OTHER END OF CONDUIT THAT IS
LOCATED INSIDE ORIGINAL PANEL.
12. EXISTING GROUNDING ELECTRODE
CONDUCTOR AND CONDUIT, FROM MAIN
SERVICE DISCONNECT TO WATER
SERVICE PIPE LOCATED IN CLOSET.
DISCONNECT AND REMOVE. REFER TO
"NEW POWER RISER DIAGRAM".
13. EXISTING BRANCH CIRCUIT WIRING TO BE
DEMOLISHED FROM THIS PANEL TO THE
FIRST DEVICE IN EACH CIRCUIT. NEW
BRANCH CIRCUIT WIRING SHALL BE
PROVIDED TO THAT FIRST DEVICE FROM
THE NEW POWER PANEL PP-UB AS
INDICATED IN THE "NEW POWER RISER
DIAGRAM". REFER TO "NEW POWER RISER
DIAGRAM" FOR GATE HOIST WIRING.
14. REFER TO REFERENCE DRAWING
TH-1-1689 FOR EXISTING DUCTBANK
INFORMATION.
15. REMOVE EXISTING CONDUCTORS AND
PROVIDE NEW AS DESCRIBED IN "NEW
POWER RISER DIAGRAM" BELOW.
SEE NOTE 3
CIRCUIT BREAKER.
ENTRANCE RATED
SERVICE
M
UTILITY
COMPANY
METER. SEE
NOTE 6
WIRE TAP BOX
TO REMAIN
EXISTING
PULL BOX
TO REMAIN
EXISTING
PULL BOX
EMH-1 EMH-2
CONDUIT.
GND IN EXISTING 2"
PROVIDE 4-6, 1-6AWG
INTERIOR
UTILITY BUILDING UTILITY BUILDING
EXTERIOR GATE HOUSESTORAGE
GARAGE
FINISHED FLOORDAM CRESTFINISHED FLOORFINISHED FLOOR FINISHED GRADE
1. ALL EQUIPMENT AND CONDUIT AND WIRES
SHOWN ARE NEW UNLESS OTHERWISE
NOTED.
2. REFER TO PART PLAN FLOOR PLANS FOR
EQUIPMENT LOCATIONS.
3. PROVIDE A 208V, 225A- 3POLE SERVICE
ENTRANCE RATED ENCLOSED CIRCUIT
BREAKER. CIRCUIT BREAKER SHALL BE
LOCKABLE IN THE "OFF" POSITION FOR
LOCK-OUT/TAG-OUT.
4. EXISTING CONDUIT DUCTBANK. PROVIDE
CONDUCTORS AS INDICATED.
5. EXTEND EXISTING 2" GRS CONDUIT.
CONDUIT SHALL RUN EXPOSED UP THE
SIDE OF THE BUILDING THEN TURN IN TO
RUN ABOVE THE GARAGE CEILING TO NEW
POWER PANEL PP-UB. PROVIDE
CONDUCTORS AS INDICATED.
6. PROVIDE METER SOCKET FOR NEW UTILITY
COMPANY METER. REQUIREMENTS SHALL
BE IN ACCORDANCE WITH NATIONAL GRID.
ELECTRICAL CONTRACTOR SHALL PAY ALL
BACK CHARGES ASSOCIATED WITH THIS
CONTRACT.
7. FOR GROUNDING ELECTRODE, PROVIDE
NEW 1/0AWG-3/4" GRS AND BOND TO
WATER SERVICE AT STREET SIDE OF
METER. REFER TO GROUNDING
ELECTRODE SYSTEM DETAIL FOR FURTHER
INFORMATION.
8. PER NOTE 13 IN THE "EXISTING POWER
RISER DIAGRAM" PROVIDE NEW BRANCH
CIRCUIT WIRING FROM THE FIRST DEVICE
IN EACH CIRCUIT TO NEW PANEL PP-UB.
9. PROVIDE 6"WX6" DEEP STEEL WIREWAY
WITH SCREW ON COVER. WIREWAY SHALL
BE SURFACE MOUNTED AND RUN FROM
PULL BOX TO NEW PANEL PP-GH FOR
BRANCH CIRCUIT WIRING.
10. PROVIDE A 208VOLT, 200A-3P DISCONNECT
SWITCH.
11. PROVIDE 3"C WITH 4-250KCMIL, 1-3AWG
12. PROVIDE NEW BRANCH CIRCUIT WIRING
FROM THE FIRST DEVICE IN EACH CIRCUIT
TO NEW PANEL PP-SG.
13. PROVIDE NEW BRANCH CIRCUIT WIRING IN
ITS ENTIRETY FOR ALL THREE GATE HOIST
MOTORS. WIRING SHALL BE 3#6AWG FOR
EACH GATE HOIST MOTOR TO RUN IN
EXISTING CONDUIT. REFER TO ORIGINAL
CONSTRUCTION DRAWING TH-1-1690 FOR
FURTHER DETAIL ON EXISTING CONDITIONS
AND TO DETERMINE WIRE LENGTHS.WIRE
SHALL RUN CONTINUOUS FROM THE NEW
POWER PANEL TO EACH DISCONNECT
SWITCH IN THE OPERATING GALLERY.
14. PROVIDE A 18"X18"X6" PULL BOX. PROVIDE
MECHANICAL UNITAP KIT RATED FOR
COPPER WIRES SIZES #4AWG THROUGH
600KCMIL WITH FOUR PORTS AND DOUBLE
SIDED ENTRY AND DESIGNATED FOR
MOUNTING IN AN ENCLOSURE. PROVIDE
BURNDY BIBD604MT OR APPROVED EQUAL.
REFER TO SPECIFICATIONS FOR FURTHER
DETAILS.
PP-SG
PANEL
POWER
PROVIDE 4-2/0
&1-6AWG IN
EXISTING 2"
CONDUIT
POWER
PANEL
PP-GH
120/208V
3PH, 4W
100A MCB
POWER
PANEL
PP-UB
SEE NOTE 7
SEE
NOTE 12
1-8AWG GND.
4" GRS WITH 4-2AWG,
SEE
NOTE 12
SEE NOTE 5
SEE NOTE 5
4-6AWG,1-6AWG GND.
PULL
BOX
EXPOSED
CONDUIT FROM
FLOOR TO
WIREWAY. SEE
NOTE 11
AND 13
SEE NOTES 10
42 POLES
POWER PANEL,
SEE NOTE 4
1-4AWG GND.
4-4/0AWG,
EXISTING 4" CONDUIT
DUCTBANK TO REMAIN
FOR REUSE. SEE NOTES 14
AND 15.
SEE
NOTE 7
EXISTING ELECTRIC
MANHOLES TO
REMAIN
EXISTING ELECTRIC
MANHOLES TO
REMAIN
SEE NOTE 4
1-3AWG GND.
4-250KCMIL,
BRANCH CIRCUIT
WIRING CONDUITS.
SEE NOTE 13
SEE NOTE 8
EXISTING
25KW/31.25KVA
208VOLT, DIESEL
GENERATOR. TO
REMAIN
CB-1
DS-2
INTERIOR
UTILITY BUILDING
TYPE 1
SPD
TYPE 2
SPD
SEE NOTE 10
INTERIOR
BUILDING
UTILITY
PROVIDE NEW WIRING FROM
FIRST DEVICE IN EACH CIRCUIT
TO NEW PANEL PP-GH. SEE
NOTES 9 AND 13
MAIN SERVICE FUSED
DISCONNECT SWITCH
100A-3P. SEE NOTE 5
EXISTING
25KW/31.25KVA
208VOLT, DIESEL
GENERATOR. TO
REMAIN
E
N
L
SWITCH
THROW DISCONNECT
225A FUSED DOUBLE
208V, 3POLE 400A FRAME,
L
N
E
4" CONDUIT
MAIN ELECTRIC
SERVICE FROM
UTILITY POLE TO
REMAIN
CONDUIT
IN EXISTING
1-4AWG GND.
4-4/0AWG,
1-8AWG GND.
2"C, 4-1AWG,
1-4AWG GND.
2"C, 4-4/0AWG,
NOTE 11
SEE
CONDUIT DUCTBANK
EXISTING EMPTY 4"
DS-1 NOTE 11
SEE
SEE NOTE 14
1-4AWG GND.
2"C, 4-4/0AWG,
2"C-4#2AWG
EXISTING POWER RISER DIAGRAM NOTES:
NEW POWER RISER DIAGRAM NOTES:
A1
J
C L
IN
E
J
C L
IN
E
M J
U R
C
IC
A N
S I
D
E-602
:1
NOT TO SCALE
D1
NOT TO SCALE
E L E
C T
R
IC
A L O
N E L
IN
E R
IS
E R D
IA
G R
A M
J U
L Y
EXISTING POWER RISER DIAGRAM
NEW POWER RISER DIAGRAM
D
N G
U Y
E
| Cover Sheet & Index |
| NOTES LEGEND ABB |
| ELECTRICAL SITE PLAN EXISTING AND NEW |
| FLOOR PLAN |
| EXISTING CONDITIONS UTILITY BUILDING |
| POWER PANELS |
| ELECTRICAL RISER |