Drawings.pdf

PDF 2 MB Posted

Attached to
Electrical Upgrade at Westville Dam, Southbridge, MA
Solicitation number
W912WJ18B0019
Issued by

About this file

Drawings

View the file

Other files

File Type Posted
Bid_Abstract.pdf PDF
W912WJ18B0019-Amendment_0001.pdf PDF
SPECS.pdf PDF
W912WJ18B0019-Solicitation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

F

T H

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B 9 7

OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET

SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL

APPROVED FOR TECHNICAL ADEQUACY BY:

TECHNICAL LEAD ENGINEER DATE

DATE

DATE

DATE

DATE

APPROVED BY:

APPROVAL RECOMMENDED BY:

REVIEWED BY:

CHIEF, GEOTECHNICAL/WATER RESOURCES BRANCH

REVIEWED BY:

CHIEF, DESIGN BRANCH

ELECTRICAL SITE PLAN

DESIGN FILESHEET NO.

G-001

INDEX TO DRAWINGS

SHEET TITLE

scope of their employment as required by ER 1110-1-8152.

and registration designations of individuals appear on these project documents, within the

This project was designed by the U.S. Army Corps of Engineers. The initials or signatures

CHIEF, ENGINEERING DIVISION

THA-WV-121_G-001.DGN

SOUTHBRIDGE, MASSACHUSETTS

WESTVILLE LAKE DAM

ELECTRICAL DISTRIBUTION SYSTEM UPGRADE

J

C L

IN

E

D

H A

S S

E T

T

A N

S I

D

G-001

:1

CHIEF, GEO-ENVIRONMENTAL ENGINEERING BRANCH

DATE

APPROVAL RECOMMENDED BY:

CHIEF, TECHNICAL SUPPORT BRANCH/DEPUTY CHIEF ENG DIV

MASS.

CONN.

THOMPSON

A

N of Engineers

US Army Corps

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

New England District

COVER SHEET AND INDEX TO DRAWINGS

THA-WV-121_E-001.DGNE-001

E-101 THA-WV-121_E-101.DGN

THA-WV-121_E-103.DGN

THA-WV-121_E-601.DGN

LOCATION

PROJECT

R O

A D

R I

E V

R

KEL

L

Y R D.

S O

U

R

A D

M

A S

H

A P

A

UG

R O

D A

M A S

HA

PA

UG

B R

E A

K N

E K

C

DAOR

D A

O R

S O

U T

H

D E

N N

IS

O N

WESTVILLE

D R

I V

E

S T

R E

E T

DAM

WESTVILLE

W L

L A

E C

R O

A D

R O

A D

S H

E P

A R

D

131 P A

R K R

D

F A

IR

V

IE

W

F

IS

K H

IL

L R

O A

D

SO

U

TH

BR

ID

G E R

O

AD

RESERVOIR

QUABBIN

WARE

SPENCER

WORCESTER

16131

PROJECT

LOCATION

DANIELSON

PUTNAM

MECHANICSVILLE

WOODSTOCK

PROVIDENCE

R.I.

MASS.

EAST BRIMFIELD

FISKDALE

STURBRIDGE

SHEET NO.

SHEET TITLEDRAWING NUMBER

TH-1-1692

TH-1-1661

TH-1-166526

INDEX TO INFORMATION DRAWINGS

E-103

VICINITY MAP

NOT TO SCALE NOT TO SCALE

LOCATION PLAN

4 THA-WV-121_E-102.DGNE-102

7 THA-WV-121_E-602.DGNE-602 ELECTRICAL ONE LINE RISER DIAGRAM

TH-1-1689

TH-1-1690

TH-1-1687

SPILLWAY AND OUTLET WORKS - PROFILE AND WEIR SECTIONS

OUTLET WORKS

ARRANGEMENT OF EQUIPMENT

ELECTRICAL DISTRIBUTION PLANS DETAILS

CONTROL HOUSE AND SPILLWAY ELECTRICAL PLANS

UTILITY BUILDING - PLUMBING, HEATING AND ELECTRICAL

UTILITY BUILDING AND STORAGE GARAGE FLOOR PLANS EXISTING AND NEW CONDITIONS

GATEHOUSE FLOOR PLAN EXISTING AND NEW CONDITIONS

C O

V E

R S

H E

E T A

N D I

N D

E X T

O D

R A

W

IN

G S

34 TH-1-1673 CONTROL HOUSE - STEEL REINFORCEMENT, ROOF SLAB & OPERATING FLOOR SLAB

J U

L Y

JULY 2018

ELECTRICAL NOTES, LEGEND, ABBREVIATIONS AND GROUNDING DETAIL

E-601 PANEL BOARD SCHEDULES

W912WJ18B0019

M J

U R

C

IC

D

N G

U Y

E N

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B

G

PANEL

PP-UBDS-1

SWITCH

TRANSFER

GENERATOR

CB-1

BREAKER

CIRCUIT

ENTRANCE

SERVICE

TRANSFORMER

NOTES:

1. NEUTRAL SHALL ONLY BE GROUNDED AT THE NEW 225A CIRCUIT

BREAKER CB-1.

2. THE CONTRACTOR SHALL MODIFY THE EXISTING GROUNDING SCHEME TO

UNDING CONDUCTORS, AND THE PANEL ENCLOSURE.

3. THE CONTRACTOR SHALL INSURE THAT THE GATEHOUSE GROUNDING

ELECTRODE IS CONNECTED TO THE GROUND BUS ONLY AND THE NEW

FEEDER EQUIPMENT GROUND CONDUCTOR.

N

G

DS-2

DISC. SW. PANEL

PP-SG

PANEL

PP-GH

NN N

G GG

N

G

N

AMPERES

CONDUIT

CIRCUIT

CIRCUIT BREAKER

BUILDING

EXHAUST FAN

EMERGENCY

ELECTRICAL METALLIC TUBING

GROUND OR GROUNDING

FULL LOAD AMPERES

THOUSAND CIRCULAR MILS

GALVANIZED RIGID METALLIC CONDUIT

kcmil

FLA

FT

GRMC

GND,G

FEET

EM

EMT

EF

CB

CKT

BATT

C

BLDG

A

QUANTITY

SYMMETRICAL

POLYVINYL CHLORIDE

RIGID METAL CONDUIT

TRANSFORMER

UNLESS OTHERWISE NOTED

UNDERWRITERS LABORATORIES

XFMR

W

V

WIRE

VOLT

UL

U.O.N.

SP

SYM

SPARE

PWR

QTY

PVC

RMC

POWER

KILOWATTS

LIGHTING

MISCELLANEOUS

MAIN LUGS ONLY

KILOVOLT AMPERES

MAIN CIRCUIT BREAKER

ASSOCIATION

NOT TO SCALE

NATIONAL ELECTRICAL

NATIONAL ELECTRIC CODE

MANUFACTURES ASSOCIATION

NATIONAL FIRE PROTECTION

NTS

PNL PANEL

NEC

NEMA

NFPA

MCB

MLO

MISC

kW kVA

LTG

GENERAL ABBREVIATIONS

CABINET UNIT HEATERCUH

EXISTING UTILITY POLE TO REMAIN

E

E

EQUIPMENT LEGEND

DISCONNECT SWITCH (UNFUSED)

DISCONNECT SWITCH (FUSED)

PANELBOARD

SYSTEM GROUND OR EQUIPMENT GROUND

PANEL

SPD

SUPPRESSER)

SURGE PROTECTIVE DEVICE (TRANSIENT VOLTAGE SURGE

PB PULL BOX

GENERAL NOTES:

WIRING DEVICES LEGEND

XL

XD

XN

XR

XM

RESPONSIBLE FOR MAINTAINING CIRCUITRY TO DEVICES

PANELBOARD AS SPARE. CONTRACTOR SHALL BE

CONDUIT AS REQUIRED SO AS TO PROVIDE A

COMPLETE OPERATIONAL INSTALLATION.

TO BE REMOVED. CUT BACK AND MAKE SAFE ALL

EQUIPMENT TO BE REMOVED AND REPLACED WITH NEW.

"XL" ADJACENT TO EQUIPMENT DENOTES RELOCATED

EXISTING AT NEW LOCATION

UNAFFECTED BY DEMOLITION.

"XD" ADJACENT TO EQUIPMENT DENOTES EXISTING

"XR" ADJACENT TO EQUIPMENT DENOTES EXISTING

"XN" ADJACENT TO EQUIPMENT DENOTES EXISTING

"XM" ADJACENT TO EQUIPMENT DENOTES EXISTING

SYMBOLS OUT OF FUNCTION DENOTE EXISTING

TO BE RELOCATED AS SHOWN. CUT BACK AND/OR

EXTEND EXISTING BRANCH CIRCUIT WIRING AND

EQUIPMENT TO REMAIN.

EXISTING EQUIPMENT LEGEND

IN EXISTING LOCATION.

TO BE REMOVED, STORED, CLEANED AND REINSTALLED

"XS" ADJACENT TO EQUIPMENT DENOTES EXISTING

XS

ASSOCIATED BRANCH CIRCUIT WIRING AND CONDUIT

BACK TO POWER SOURCE AND LABEL BREAKER IN

EMH-1

CMH-1

COMMUNICATIONS MANHOLE. NUMERAL INDICATES

MANHOLE NUMBER

ELECTRIC MANHOLE. NUMERAL INDICATES MANHOLE

NUMBER

J

C L

IN

E

D

H A

S S

E T

T

A N

S I

D

E-001

:1

M J

U R

C

IC

BATTERY

ELECTRIC UNDERGROUND UTILITY LINE

ELECTRIC OVERHEAD UTILITY LINE

COMM COMMUNICATION OVERHEAD UTILITY LINE

COMM COMMUNICATION UNDERGROUND UTILITY LINE

ELEVATIONEL.

J U

L Y

RV

CHARACTERISTICS.

REFER TO SPECIFICATIONS FOR ALL OTHER

PROVIDE (1) 5-20R GFI RECEPTACLES.

30A-1P AND 20A-1P.

CIRCUIT BREAKER PROVISIONS SHALL BE 50A-2P,

125 CONTINUOS AMPERE ,NEMA 3R ENCLOSURE

RV POWER CONNECTION 240V, 1 PHASE 60Hz, ATS AUTOMATIC TRANSFER SWITCH

DIST DISTRIBUTION

DP DISTRIBUTION PANEL

RECREATIONAL VEHICLERV

DS

A1

NOT TO SCALE

A N

D G

R O

U N

D

IN

G D

E T

A

IL

E L E

C T

R

IC

A L N

O T

E S L E

G E

N D

A B

B R

E V

IA

T

IO

N S

GROUNDING ELECTRODE SYSTEM DETAIL

LINE TYPE LEGEND

COR CONTRACTING OFFICER'S REPRESENTATIVE

SPD

GRS

UNDERGROUND OR UNDERGRADEUG

TYP. TYPICAL

MIN. MINIMUM

GALVANIZED RIGID STEEL

SURGE PROTECTIVE DEVICE

G GROUND

N NEGATIVE

DISCONNECT SWITCH

AWG AMERICAN WIRE GAUGE

125 VOLT, 2 POLE, 3 WIRE, 20 AMP., DUPLEX RECEPTACLE.

D

N G

U Y

E N

M

J JUNCTION BOX

ELECTRIC MOTOR

$3

SINGLE POLE TOGGLE SWITCH

THREE WAY TOGGLE SWITCH

GFCI GROUND FAULT CIRCUIT INTERRUPTER

INFORMATION TECHNOLOGYIT

NP NAME PLATE

G.

F.

E.

D.

C.

B.

A.

COMPLETE AND PROPER ELECTRICAL INSTALLATION. THIS WORK SHALL INCLUDE:

INCLUDED IN THE CONTRACT AS REQUIRED TO PROVIDE AND MAINTAIN A

ALL NECESSARY ADDITIONS AND ALTERATIONS TO EXISTING WORK SHALL BE11.

INSTALLATIONS.

FOR EASE OF DISCONNECTING WITH MINIMUM OF INTERFERENCE WITH OTHER

OF EQUIPMENT COMPONENTS AS MUCH AS PRACTICAL. CONNECT THE EQUIPMENT

ELECTRICAL EQUIPMENT TO FACILITATE MAINTENANCE, REPAIR AND REPLACEMENT

AND OVERHEAD EQUIPMENT TO PROVIDE MAXIMUM HEADROOM POSSIBLE. INSTALL

WHERE MOUNTING HEIGHTS ARE NOT DETAILED, INSTALL ELECTRICAL SERVICES10.

ONE BOX WITH A SINGLE COVER PLATE.

WHENEVER SIMILAR DEVICES ARE SHOWN TOGETHER, THEY SHALL BE GANGED IN9.

FIRE RESISTANT CONSTRUCTION.

SIDE WALL HORIZONTAL SPACING COMPLY WITH STATE BUILDING CODE REGARDING

ASSEMBLIES SUCH THAT AREA OF BOX PER WALL AREA AND OUTLET ON OPPOSITE

COORDINATE EXACT LOCATION OF ALL BOXES IN TWO HOUR OR LESS RATED

SHALL BE MOUNTED 8" APART ON CENTER HORIZONTALLY. CONTRACTOR SHALL

RECEPTACLES AND TELECOMMUNICATIONS OUTLETS SHOWN ADJACENT ON DRAWINGS8.

THREE CIRCUITS PER CONDUIT HOME RUN.

RECEPTACLE CIRCUITS ONLY MAY BE EXEMPTED, LIMITED TO NOT MORE THAN

SHALL NOT BE PERMITTED WITHOUT PRIOR WRITTEN APPROVAL. LIGHTING AND

CONSOLIDATION OF INDIVIDUAL CONDUIT HOME RUNS SHOWN ON THE DRAWINGS7.

FIXTURE OR EQUIPMENT UNLESS OTHERWISE NOTED.

MOUNTING HEIGHTS OF ALL DEVICES ARE TO CENTER OF DEVICES, OUTLET,6.

NEC 250.122.

ALL CIRCUITS TO BE RUN WITH GREEN GROUNDING CONDUCTOR SIZED PER5.

REQUIRING A NEUTRAL I.E. NO SHARED NEUTRAL.

SEPARATE NEUTRAL CONDUCTORS SHALL BE RUN WITH ALL BRANCH CIRCUITS4.

TYPE OF SYSTEM, PANEL AND CIRCUIT NUMBER.

FOR ALL ALTERED PANELS. LABEL AND IDENTIFY ALL JUNCTION BOXES WITH

EQUIPMENT SERVED, ROOM NUMBERS, SPARE OR SPACE. UPDATE DIRECTORIES

ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING3.

COUNTERS, ETC.

COORDINATE ALL DEVICE LOCATIONS WITH ACTUAL DOOR SWINGS, CABINETS,

DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT.2.

CONTRACTING OFFICERS REPRESENTATIVE.

SHALL BE SCHEDULED IN ACCORDANCE WITH THE SPECIFICATIONS AND THE

ELECTRIC SHUT-DOWNS SHALL BE AS MINIMAL IN DURATION AS POSSIBLE. WORK

TO MINIMIZE DISRUPTION TO THE FACILITY.

ALL WORK FOR THIS PROJECT SHALL BE CAREFULLY COORDINATED1.

WORK OF THIS CONTRACT.

RESTORED TO ITS ORIGINAL AND OPERATING CONDITION AFTER THE

VERIFICATION THAT THE EXISTING EQUIPMENT OR SYSTEM SHALL BE I.

H. REMOVAL AND DISPOSAL OF ALL EQUIPMENT INDICATED TO BE DEMOLISHED.

AND ACCESSIBLE LOCATIONS.

REMOVAL OF UNUSED CONDUIT FROM CEILINGS, EXPOSED AREAS

IN FLOORS OR WALLS.

ABANDONMENT IN PLACE OF UNUSED CONDUIT WHERE CONCEALED

REMOVAL AND DISPOSAL OF UNUSED CONDUIT OR CONDUCTORS.

CLEAN AND IN WORKING ORDER.

TO THE CONTRACTING OFFICER’S REPRESENTATIVE SHALL BE

VERIFICATION THAT EQUIPMENT THAT IS TO BE TURNED OVER THE

RELOCATION OF PIPING AND DUCTWORK TO ALLOW FOR WORK.

TEMPORARY WORK.

ALLOW FOR CONTINUED OPERATION DURING THE WORK, TO INCLUDE

DISCONNECTION/RECONNECTION/REINSTALLATION OF EQUIPMENT TO

RELOCATION OF EQUIPMENT TO ALLOW FOR WORK.

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B

BUILDING

UTILITY

STORAGE GARAGE

GATE

HOUSE

M A

R J O

R

IE

L

A N

E

SEE NOTE 6

TO REMAIN

GRID UTILITY POLE

EXISTING NATIONAL

Q U

IN

E B

A U

G R

IV

E

R

F L

O W

MANHOLE CMH-1 TO REMAIN

EXISTING COMMUNICATIONS

EMH-1 TO REMAIN

EXISTING MANHOLE

SEE NOTES 2 AND 3

MANHOLE EMH-2

EXISTING ELECTRICAL

MANHOLE CMH-2 TO REMAIN

EXISTING COMMUNICATIONS

DUCTBANK TO REMAIN

EXISTING UNDERGROUND

DUCTBANK TO REMAIN

EXISTING UNDERGROUND

SEE NOTE 5

E

FROM UTILITY

INCOMING POWER

A1

30' 60'0SCALE: 1" = 30'

ELECTRICAL SITE PLAN

J

C L

IN

E

D

H A

S S

E T

T

A N

S I

D

E-101

E L E

C T

R

IC

A L S

IT

E P

L A

N

:1

M J

U R

C

IC

J U

L Y

D

N G

U Y

E N

REFERENCE WORK REQUEST NUMBER 2599-7422.

ENTRANCE WORK CALL NATIONAL GRID AT 800-375-7405 AND

THREE (3) 10KVA TRANSFORMERS TO REMAIN. FOR SERVICE

6. EXISTING NATIONAL GRID UTILITY POLE NUMBER 17-1 AND

SHEET E-001 FOR FURTHER INFORMATION.

REUSE EXISTING PEDESTAL. REFER TO EQUIPMENT LEGEND ON

REPLACED WITH NEW RV POWER CONNECTION.

5. EXISTING RV POWER CONNECTION PEDESTAL MOUNTED TO BE

AND STORAGE GARAGE FROM THE UTILITY BUILDING.

CONTRACTOR SHALL PROVIDE NEW FEEDERS TO GATE HOUSE

4. EXISTING UNDERGROUND DUCTBANK TO REMAIN. ELECTRICAL

AND COMPLETION OF PULLING OF CONDUCTORS.

TO SCHEDULE POWER SHUT DOWN FOR FINAL CONNECTIONS

STAFF OF THE WESTVILLE LAKE DAM 72 HOURS IN ADVANCE

3. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE

2. FOR ELECTRICAL RISER DIAGRAM REFER TO SHEET E-602.

1. FOR LEGEND AND GENERAL NOTES SEE SHEET E-001.

NOTES:

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B

S S S3 3

DN.

OPEN HATCH

SS

OPERATING ROOM FLOOR OBSERVATION DECK EL. 587.50

12"X12"X6" DEEP TELEPHONE CABINET

UP TO FLOODLIGHT #1

NP 8 FLOODLIGHT PB. STA.

SWITCH NP6

VG-4

NP7 - FLOODLIGHT

4#12

TELEPHONE OUTLET

BATTERY CHARGER

2"C-4#2

HEATER

SERVICE SWITCH NP 5,5A & 5B

XD

XD

CEILING LIGHTS

CANOPY FIXTURE

2" C - 4#2

TO DIESEL BATTERY CHARGER

EXISTING EMERGENCY

ELECTRICAL GENERATOR

TO REMAIN

CAP 6" ABOVE FLOOR

TWO 1 1/2" CONDUIT

DEMOLISHED

PANEL TO BE

(DP) NP4 POWER

ORIGINAL DIST. PANEL

FOR RELATED WORK

REFER TO DRAWING E-602

4" C-4# 4/0 TO PANEL (DP) NP4

4" FIBER

4" TELEPHONE CONDUIT 8#14 IRON PULL WIRE

4" C-1- 3/C #12 FLOODLIGHT CONTROL

S S S3 3

DN.

OPEN HATCH

SS

OPERATING ROOM FLOOR OBSERVATION DECK EL. 587.50

12"X12"X6" DEEP TELEPHONE CABINET

UP TO FLOODLIGHT #1

NP 8 FLOODLIGHT PB. STA.

NP7 - FLOODLIGHT

4#12

BATTERY CHARGER

DISCONNECT SWITCH DS-2

POWER PANEL PP-GH

CEILING LIGHTS

SEE NOTE 2

4" TELEPHONE CONDUIT 8#14 IRON PULL WIRE

4" FIBER

EXISTING EMERGENCY

ELECTRICAL GENERATOR

TO REMAIN

CANOPY FIXTURE

2" C - 4#2

4" C-1- 3/C #12 FLOODLIGHT CONTROL

SWITCH DS-1

DOUBLE THROW DISCONNECT

FOR RELATED WORK

REFER TO DRAWING E-602

J

C L

IN

E

D

H A

S S

E T

T

A N

S I

D

E-102

G A

T E

H O

U S

E F

L O

O R P

L A

N

:1

C5

N

0 4' 8'2'SCALE: 1/4" = 1'-0"

M J

U R

C

IC

C1

N

0 4' 8'2'SCALE: 1/4" = 1'-0"

EXISTING CONDITIONS GATE HOUSE FLOOR PLAN NEW CONDITIONS GATE HOUSE FLOOR PLAN

E X

IS

T

IN

G A

N D N

E W C

O N

D

IT

IO

N S

NOTES:

J U

L Y

D

N G

U Y

E N

REFER TO DRAWING E-602 FOR FURTHER INFORMATION.

CIRCUIT TO BE REPLACED AND POWERED VIA NEW PANEL PP-GH.

3. PANEL TUB AND COVER TO REMAIN. WIRING FROM FIRST DEVICE IN EACH

ORIGINAL CIRCUIT SHALL REMAIN ON SAME CIRCUIT.

REFER TO PANELBOARD SCHEDULE ON DRAWING E-601. REMAINING DEVICES ON

IT IS ON A DEDICATED CIRCUIT. PROVIDE 2#12,1#12GND TO PANEL PP-GH CIRCUIT 24.

2. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW WIRING FOR THIS DEVICE SO THAT

SEE DRAWING E-602 FOR FURTHER INFORMATION ON WORK REQUIREMENTS.

1. THIS DRAWING SHOWS GENERAL LOCATIONS OF EXISTING AND NEW EQUIPMENT.

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B

J M

M

M

M

M

LTG. PANEL - NP 12

E2-IT DUCT LINE

CAP AND TAG

STUB 6" ABOVE FLOOR

4" TEL. CONDUIT

CONTROL HOUSE SWITCH NP-11

MAIN SERVICE SWITCH NP-18

M

2" C-4#2

NOTE 2

XD

XD

XD

RV

XN

XD

RV

XN

XD

XD

XD

XD

HEATER ROOM

OFFICE

GARAGE

RESTROOM

SHOWER WITH TUB

STORAGE ROOM

MEETING ROOM

S

C

SSS

S

BURNER

OIL

S

S

S

TO EMH-1

TO CMH-1

NP-10

UTILITY BUILDING SERVICE SWITCH

S

NP-15

NP-14

NP-16

FLOODLIGHT CONTROL Pb. NP-13

COMPRESSOR

TO REMAIN

EXISTING PULL BOX

SEE NOTE 1

HEATER ROOM

OFFICE

GARAGE

J M

M

M

M

M

E2-IT DUCT LINE

RV

RV

RESTROOM

SHOWER WITH TUB

CB-1

RATED CIRCUIT BREAKER

NEW SERVICE ENTRANCE

MEETING ROOM

STORAGE ROOM

S

FLOODLIGHT CONTROL Pb. NP-13

S S

C

S

BURNER

OIL

NP-15

NP-14

NP-16

S

S

TO EMH-1

TO CMH-1

COMPRESSOR

S

S

NEW POWER PANEL PP-UB

EXISTING PULL BOX

GARAGE DOOR GARAGE DOOR GARAGE DOOR

FOR FURTHER INFORMATION

REFER TO DRAWING E-602

GENERATOR PANEL TO BE DEMOLISHED

FOR FURTHER INFORMATION

REFER TO DRAWING E-602

GENERATOR PANEL TO BE DEMOLISHED

GARAGE DOOR GARAGE DOOR GARAGE DOOR

FOR FURTHER INFORMATION

REFER TO DRAWING E-602

NEW POWER PANEL PP-SG

J

C L

IN

E

D

H A

S S

E T

T

M J

U R

C

IC

A N

S I

D

E-103

:1

E1

N

SCALE: 1/4" = 1' - 0"

E6

N

SCALE: 1/4" = 1' - 0"

A1

N

SCALE: 1/4" = 1' - 0"

A6

N

SCALE: 1/4" = 1' - 0"

EXISTING CONDITIONS UTILITY BUILDING FLOOR PLAN

EXISTING CONDITIONS STORAGE GARAGE FLOOR PLAN

NEW CONDITIONS UTILITY BUILDING FLOOR PLAN

NEW CONDITIONS STORAGE GARAGE FLOOR PLAN

S T

O R

A G

E G

A R

A G

E F

L O

O R P

L A

N S

NOTES:

E X

IS

T

IN

G A

N D N

E W C

O N

D

IT

IO

N S

J U

L Y

U T

IL

IT

Y B

U

IL

D

IN

G A

N D

2. THIS SHEET SHOWS GENERAL LOCATIONS OF EXISTING AND NEW EQUIPMENT.

1. SEE SHEET E-602 FOR FURTHER INFORMATION AND WORK REQUIREMENTS.

D

N G

U Y

E N

NOTES:

2. REFER TO EXISTING POWER RISER DIAGRAM ON DRAWING E-602 FOR FURTHER INFORMATION.

1. REFER TO ELECTRICAL SITE PLAN E-101 FOR ELECTRICAL SERVICE INFORMATION.

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B

TRIP

BREAKER

PANELBOARD SCHEDULE PP-GH

DESCRIPTION

DEHUMID & RECEPTS LEVEL 3

POLE

EXTERIOR LIGHTS

DESCRIPTION

MOUNTING: SURFACE

LOAD SUB-TOTALS: 26.8kVA

OPERATING LEVEL RECEPTS

LIGHTING LEVEL 550

LIGHTING OPERATING GALLERY

BATTERY CHARGER

LIGHTING OPERATING LEVEL

AIC RATING: 10K

LIGHTING ELEV 572.17

NO.

CKT.

A

B

C

A

B

C

A

B

C

A

B

C

NO.

CKT.

TRIP

BREAKER

POLE

kVA

LOAD

kVA

LOAD

0.5

1.0

1.0

15.6 10.5

RECEPTS ELEV. 550 OPERATING GALLERY

GATE HOIST #3

0.6

0.2

0.6

0.4

BUSSING: COPPER

MAINS: 100A MCB GROUND BUS: EQUIPMENT

TUB: SINGLE

25 26

27 28

29 30

0.6

1.0

0.5

0.5

5.6 0.4

5.6

201 -

202 -

LIGHTING TUNNEL

GATE HOIST #1

RECEPTS OPERATING LEVEL SOUTH&WEST WALL

SPARE

SPARE

1.0 201FLOOD LIGHTS

- 201SPARE

- 201SPARE

WIREWIRE

ELEV 530 RECEPTS AND EBU

OIL BURNER

SPARE

201 .70

202 -

LIGHTING OPERATING GALLERY

GATE HOIST #2 4035.6

201 0.2 12

0.5 201

TRIP

BREAKER

PANELBOARD SCHEDULE PP-UB

DESCRIPTION

SEWER PUMP

POLE

FRIDGE

DESCRIPTION

MOUNTING: SURFACE

LOAD SUB-TOTALS: 69.4KVA

RANGE

OUTSIDE PHOTOEYE ON LIGHT

MISC LIGHTS

AIC RATING: 10 K

GARAGE DOOR OPENER

NO.

CKT.

A

B

C

A

B

C

A

B

C

A

B

C

NO.

CKT.

TRIP

BREAKER

POLE

kVA

LOAD

kVA

LOAD

0.5

1.2

32.4 37.0

FAN LIGHT

RECEPTS KITCHEN GFCI

1.0

0.2

0.5

0.6

BUSSING: COPPER

MAINS: 175A MCB GROUND BUS: EQUIPMENT

TUB: SINGLE

25 26

27 28

29 30

6.25

6.6

0.4

0.4

RECEPTS

SPARE0.2 201PLUG ON BACK WALL

5.0 302DRYER

WIREWIRE

RECEPTS KITCHEN GFCI

RV PEDESTAL #1

SPARE

502 8.3

201 -

RV PEDESTAL #2

WATER HEATER 1.2

X

12 8.3 502

GARAGE LIGHTS 0.6

PANEL GFCI 1.0

GARAGE GFCI AND ALARM 0.5

GFCI ABOVE GARAGE DOOR 0.2

32A

B

C

37 38

39 40

603 22.0 PANEL STORAGE GARAGE PP-SG201SPARE -

SPARE

- 201SPARE

A/C 1522.5

201 - SPARE-SHOWER AREA GFCI 2010.2

A

B

C

A

B

201 0.6 LIVING ROOM LIGHTS AND PLUGS12

201 1.0 BOILER12

201 SPARE- -

SPARE- -

TRIP

BREAKER

PANELBOARD SCHEDULE PP-SG

DESCRIPTION

WELDER

POLE

TABLE SAW

DESCRIPTION

MOUNTING: SURFACE

LOAD SUB-TOTALS: 37.6KVA

HEATER TOOL ROOM

RECEPTACLE DOWN STAIRS

AIC RATING: 10 K

NO.

CKT.

A

B

C

A

B

C

A

B

C

A

B

C

NO.

CKT.

TRIP

BREAKER

POLE

kVA

LOAD

kVA

LOAD

3.0

5.0

20.6 17.0

AIR COMPRESSOR

BAY 3 LIGHTS

0.4

BUSSING: COPPER

MAINS: 60A MCB GROUND BUS: EQUIPMENT

TUB: SINGLE

25 26

27 28

29 30

14.0

3.0

1.6

0.8

WIREWIRE

GARAGE DOOR

TOOL ROOM OUTLETS

SPARE

201 1.0

201 -

BAY 3 220VOLT RECEPTACLE

X

12 3.0 202

FLOOD LIGHT 0.1

- 201SPARE

- 201SPARE

- 201SPARE

A

B

C

201 0.8 DOWNSTAIRS LIGHTS12

201 0.2 FUEL PUMP EMERGENCY LIGHTS12

EXHAUST FAN DAMPER 0.5 201

0.5FURNACE

0.5TOOL ROOM LIGHTS

1.0OUTLETS DOWNSTAIRS

1.0OUTLETS BAY 3 BAY 2 RECEPTS201 - 12

201 SPARE- 12

SPARE- 12

41 42- 201- C

A

B

C

RECEPTACLE OPERATING LEVEL WEST WALL,

SOUTH OF EXISTING ELEC PANEL

D

H A

S S

E T

T

A N

S I

D

E-601

:1

M J

U R

C

IC

J

C L

IN

E

P A

N E

L B

O A

R D S

C H

E D

U L E

S

J U

L Y

D

N G

U Y

E

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T

A -W

V -1

S O

U T

H B

R

ID

G E

M A

S S

A C

H U

S E

T T S

W E

S T

V

IL

L E L

A K

E D

A M

E L E

C T

R

IC

A L D

IS

T R

IB

U T

IO

N S

Y S

T E

M U

P G

R A

D E

SHEET ID

®of Engineers

US Army Corps

W

W J

B

SWITCH

DISCONNECT

ENTRANCE

SERVICE

M

UTILITY COMPANY

METER

SERVICE ENTRANCE

DISCONNECT FOR

STORAGE GARAGE

CIRCUIT BREAKER

ENCLOSED

50A-1POLE

BOX

TAP

GATE TOWER SERVICE SWITCH.

120/208V, 100A-3POLE, FUSED

SWITCH

WIRE TAP BOX

TO REMAIN

SECURITY CONTROL

PANEL. TO REMAIN. SEE

NOTE 6

UTILITY BUILDING

SERVICE SWITCH.

120/208V, 50A-3POLE

FUSED SWITCH

EXISTING

PULL

BOX TO

REMAIN

DEVICE

PROTECTIVE

3 PHASE SURGE

NORMAL POWER PANEL.

42POLES, 120/208V,

3PHASE,100A MCB.

PLUG

CONNECTION FOR

PORTABLE

GENERATOR

CONDUIT

FLEXIBLE

PANEL

POWER

100A-3POLE FUSED

DOUBLE THROW

DISCONNECT SWITCH

60A-3POLE FUSED

DISCONNECT SWITCH.

EMERGENCY FEED TO

UTILITY BUILDING

PULL/TAP

BOX TO

REMAIN

REMOVED

WIREWAY TO BE

6"X6"X6"

EMH-1 EMH-2

2"C-4#2AWG.

4#2AWG TO BE REMOVED.

REFER TO NEW POWER RISER

DIAGRAM BELOW FOR

FURTHER INFORMATION

4" CONDUIT

MAIN ELECTRIC

SERVICE FROM

UTILITY POLE TO

REMAIN. SEE NOTE 9

2" CONDUIT WITH

4-1AWG & 1-8AWG

GND TO STORAGE

GARAGE. SEE NOTE 8

MCB.

1PHASE, 60A

120/208V, 10POLES,

PANEL.

POWER

EMERGENCY

BUILDING

UTILITY

SWITCH IN

DISCONNECT

MAIN SERVICE

2" CONDUIT TO

CONDUIT "LB" FOR CONDUIT

ENTRANCE INTO THE BUILDING

4" EMPTY CONDUIT

TO REMAIN. SEE

NOTE 4

3/4" EMPTY CONDUIT

TO REMAIN. SEE

NOTE 4

POWER

GEN

POWER

UTILITY

2" CONDUIT

EMBEDDED IN

CONCRETE WALL

WITH 4-2AWG.

INTERIOR

UTILITY BUILDING UTILITY BUILDING

EXTERIOR

GATE HOUSESTORAGE

GARAGE

FINISHED FLOORDAM CRESTFINISHED FLOORFINISHED FLOOR FINISHED GRADE

1. ALL EQUIPMENT AND CONDUIT AND WIRES

SHOWN ARE EXISTING TO BE REMOVED

UNLESS NOTED OTHERWISE.

2. EXISTING CONDUITS TO REMAIN SHALL BE

REUSED UNLESS NOTED OTHERWISE.

3. REFER TO PART PLAN FLOOR PLANS FOR

EQUIPMENT LOCATIONS.

4. EXISTING EMPTY CONDUIT SHALL BE

SEALED AND CAPPED IN PLACE.

5. SERVICE CONDUCTORS ENTER THIS

SWITCH THROUGH THE BACK.

6. SECURITY CONTROL PANEL SHALL BE

RELOCATED BY OTHERS PRIOR TO

COMMENCEMENT OF THIS PROJECT.

7. REMOVE EXISTING FEEDER CONDUCTORS.

CUT CONDUIT AT BOTH ENDS 6" ABOVE

FINISHED FLOOR, SEAL AND CAP AT BOTH

ENDS.

8. EXISTING CONDUIT TO REMAIN. REMOVE

EXISTING FEEDER CONDUCTORS,

PROVIDE NEW WORK AS INDICATED ON

"NEW POWER RISER DIAGRAM".

9. EXISTING #2AWG CONDUCTORS SHALL

REMAIN. DISCONNECT AND RECONNECT IN

ASSOCIATION WITH WORK INDICATED ON

"NEW POWER RISER DIAGRAM".

COORDINATE ALL UTILITY WORK WITH

NATIONAL GRID. THE ACCOUNT NUMBER

FOR THIS SITE IS 52981-45002.

10. EXISTING PANEL IS MOUNTED IN FRONT

OF THE ORIGINAL RECESSED BACK BOX

OF THE ORIGINAL POWER PANEL. RETAIN

PANELBOARD TUB AND COVER TO BE

USED AS A PULL BOX. CUT OPENING IN

BACK OF TUB THE SIZE OF THE ORIGINAL

OPENING, DE-BURR AND PROVIDE

CORRUGATED LOOM TUBING AROUND ALL

CUT EDGES. CIRCUITS TO NEW PANEL

SHALL BE SURFACE MOUNTED. REFER TO

NEW ELECTRICAL RISER DIAGRAM BELOW.

COORDINATE CUT OVER WITH COR TO

MINIMIZE POWER OUTAGE.

11. REMOVE EXISTING FEEDER CONDUCTORS.

CUT BACK EXISTING EXPOSED CONDUIT 6"

ABOVE THE FLOOR, SEAL AND CAP.

CAP OTHER END OF CONDUIT THAT IS

LOCATED INSIDE ORIGINAL PANEL.

12. EXISTING GROUNDING ELECTRODE

CONDUCTOR AND CONDUIT, FROM MAIN

SERVICE DISCONNECT TO WATER

SERVICE PIPE LOCATED IN CLOSET.

DISCONNECT AND REMOVE. REFER TO

"NEW POWER RISER DIAGRAM".

13. EXISTING BRANCH CIRCUIT WIRING TO BE

DEMOLISHED FROM THIS PANEL TO THE

FIRST DEVICE IN EACH CIRCUIT. NEW

BRANCH CIRCUIT WIRING SHALL BE

PROVIDED TO THAT FIRST DEVICE FROM

THE NEW POWER PANEL PP-UB AS

INDICATED IN THE "NEW POWER RISER

DIAGRAM". REFER TO "NEW POWER RISER

DIAGRAM" FOR GATE HOIST WIRING.

14. REFER TO REFERENCE DRAWING

TH-1-1689 FOR EXISTING DUCTBANK

INFORMATION.

15. REMOVE EXISTING CONDUCTORS AND

PROVIDE NEW AS DESCRIBED IN "NEW

POWER RISER DIAGRAM" BELOW.

SEE NOTE 3

CIRCUIT BREAKER.

ENTRANCE RATED

SERVICE

M

UTILITY

COMPANY

METER. SEE

NOTE 6

WIRE TAP BOX

TO REMAIN

EXISTING

PULL BOX

TO REMAIN

EXISTING

PULL BOX

EMH-1 EMH-2

CONDUIT.

GND IN EXISTING 2"

PROVIDE 4-6, 1-6AWG

INTERIOR

UTILITY BUILDING UTILITY BUILDING

EXTERIOR GATE HOUSESTORAGE

GARAGE

FINISHED FLOORDAM CRESTFINISHED FLOORFINISHED FLOOR FINISHED GRADE

1. ALL EQUIPMENT AND CONDUIT AND WIRES

SHOWN ARE NEW UNLESS OTHERWISE

NOTED.

2. REFER TO PART PLAN FLOOR PLANS FOR

EQUIPMENT LOCATIONS.

3. PROVIDE A 208V, 225A- 3POLE SERVICE

ENTRANCE RATED ENCLOSED CIRCUIT

BREAKER. CIRCUIT BREAKER SHALL BE

LOCKABLE IN THE "OFF" POSITION FOR

LOCK-OUT/TAG-OUT.

4. EXISTING CONDUIT DUCTBANK. PROVIDE

CONDUCTORS AS INDICATED.

5. EXTEND EXISTING 2" GRS CONDUIT.

CONDUIT SHALL RUN EXPOSED UP THE

SIDE OF THE BUILDING THEN TURN IN TO

RUN ABOVE THE GARAGE CEILING TO NEW

POWER PANEL PP-UB. PROVIDE

CONDUCTORS AS INDICATED.

6. PROVIDE METER SOCKET FOR NEW UTILITY

COMPANY METER. REQUIREMENTS SHALL

BE IN ACCORDANCE WITH NATIONAL GRID.

ELECTRICAL CONTRACTOR SHALL PAY ALL

BACK CHARGES ASSOCIATED WITH THIS

CONTRACT.

7. FOR GROUNDING ELECTRODE, PROVIDE

NEW 1/0AWG-3/4" GRS AND BOND TO

WATER SERVICE AT STREET SIDE OF

METER. REFER TO GROUNDING

ELECTRODE SYSTEM DETAIL FOR FURTHER

INFORMATION.

8. PER NOTE 13 IN THE "EXISTING POWER

RISER DIAGRAM" PROVIDE NEW BRANCH

CIRCUIT WIRING FROM THE FIRST DEVICE

IN EACH CIRCUIT TO NEW PANEL PP-UB.

9. PROVIDE 6"WX6" DEEP STEEL WIREWAY

WITH SCREW ON COVER. WIREWAY SHALL

BE SURFACE MOUNTED AND RUN FROM

PULL BOX TO NEW PANEL PP-GH FOR

BRANCH CIRCUIT WIRING.

10. PROVIDE A 208VOLT, 200A-3P DISCONNECT

SWITCH.

11. PROVIDE 3"C WITH 4-250KCMIL, 1-3AWG

12. PROVIDE NEW BRANCH CIRCUIT WIRING

FROM THE FIRST DEVICE IN EACH CIRCUIT

TO NEW PANEL PP-SG.

13. PROVIDE NEW BRANCH CIRCUIT WIRING IN

ITS ENTIRETY FOR ALL THREE GATE HOIST

MOTORS. WIRING SHALL BE 3#6AWG FOR

EACH GATE HOIST MOTOR TO RUN IN

EXISTING CONDUIT. REFER TO ORIGINAL

CONSTRUCTION DRAWING TH-1-1690 FOR

FURTHER DETAIL ON EXISTING CONDITIONS

AND TO DETERMINE WIRE LENGTHS.WIRE

SHALL RUN CONTINUOUS FROM THE NEW

POWER PANEL TO EACH DISCONNECT

SWITCH IN THE OPERATING GALLERY.

14. PROVIDE A 18"X18"X6" PULL BOX. PROVIDE

MECHANICAL UNITAP KIT RATED FOR

COPPER WIRES SIZES #4AWG THROUGH

600KCMIL WITH FOUR PORTS AND DOUBLE

SIDED ENTRY AND DESIGNATED FOR

MOUNTING IN AN ENCLOSURE. PROVIDE

BURNDY BIBD604MT OR APPROVED EQUAL.

REFER TO SPECIFICATIONS FOR FURTHER

DETAILS.

PP-SG

PANEL

POWER

PROVIDE 4-2/0

&1-6AWG IN

EXISTING 2"

CONDUIT

POWER

PANEL

PP-GH

120/208V

3PH, 4W

100A MCB

POWER

PANEL

PP-UB

SEE NOTE 7

SEE

NOTE 12

1-8AWG GND.

4" GRS WITH 4-2AWG,

SEE

NOTE 12

SEE NOTE 5

SEE NOTE 5

4-6AWG,1-6AWG GND.

PULL

BOX

EXPOSED

CONDUIT FROM

FLOOR TO

WIREWAY. SEE

NOTE 11

AND 13

SEE NOTES 10

42 POLES

POWER PANEL,

SEE NOTE 4

1-4AWG GND.

4-4/0AWG,

EXISTING 4" CONDUIT

DUCTBANK TO REMAIN

FOR REUSE. SEE NOTES 14

AND 15.

SEE

NOTE 7

EXISTING ELECTRIC

MANHOLES TO

REMAIN

EXISTING ELECTRIC

MANHOLES TO

REMAIN

SEE NOTE 4

1-3AWG GND.

4-250KCMIL,

BRANCH CIRCUIT

WIRING CONDUITS.

SEE NOTE 13

SEE NOTE 8

EXISTING

25KW/31.25KVA

208VOLT, DIESEL

GENERATOR. TO

REMAIN

CB-1

DS-2

INTERIOR

UTILITY BUILDING

TYPE 1

SPD

TYPE 2

SPD

SEE NOTE 10

INTERIOR

BUILDING

UTILITY

PROVIDE NEW WIRING FROM

FIRST DEVICE IN EACH CIRCUIT

TO NEW PANEL PP-GH. SEE

NOTES 9 AND 13

MAIN SERVICE FUSED

DISCONNECT SWITCH

100A-3P. SEE NOTE 5

EXISTING

25KW/31.25KVA

208VOLT, DIESEL

GENERATOR. TO

REMAIN

E

N

L

SWITCH

THROW DISCONNECT

225A FUSED DOUBLE

208V, 3POLE 400A FRAME,

L

N

E

4" CONDUIT

MAIN ELECTRIC

SERVICE FROM

UTILITY POLE TO

REMAIN

CONDUIT

IN EXISTING

1-4AWG GND.

4-4/0AWG,

1-8AWG GND.

2"C, 4-1AWG,

1-4AWG GND.

2"C, 4-4/0AWG,

NOTE 11

SEE

CONDUIT DUCTBANK

EXISTING EMPTY 4"

DS-1 NOTE 11

SEE

SEE NOTE 14

1-4AWG GND.

2"C, 4-4/0AWG,

2"C-4#2AWG

EXISTING POWER RISER DIAGRAM NOTES:

NEW POWER RISER DIAGRAM NOTES:

A1

J

C L

IN

E

J

C L

IN

E

M J

U R

C

IC

A N

S I

D

E-602

:1

NOT TO SCALE

D1

NOT TO SCALE

E L E

C T

R

IC

A L O

N E L

IN

E R

IS

E R D

IA

G R

A M

J U

L Y

EXISTING POWER RISER DIAGRAM

NEW POWER RISER DIAGRAM

D

N G

U Y

E

Cover Sheet & Index
NOTES LEGEND ABB
ELECTRICAL SITE PLAN EXISTING AND NEW
FLOOR PLAN
EXISTING CONDITIONS UTILITY BUILDING
POWER PANELS
ELECTRICAL RISER

File details come from the government source that posted it.