Amendment0002_W912WJ-16-Q-0180.pdf
PDF 158 KB Posted
- Solicitation number
- W912WJ-16-Q-0180
About this file
**NOTICE AMENDMENT 0002 HAS BEEN ISSUED TO DELETE ITEM 11(a) 11(c) FROM THE BID SCHEDULE AND SUPPLY REQUIREMENT. THE SOLICITATION PERIOD HAS ALSO BEEN EXTENDED TO THE CLOSE OF BUSINESS (3 30p EST) ON 29-SEPTEMBER-2016. ALL OFFERORS MUST SUBMIT A SIGNED COPY OF THIS AMENDMENT WITH THEIR QUOTE.**
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment0001_W912WJ-16-Q-0180.pdf | ||
| Solicitation_W912WJ-16-Q-0180.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This amendment has been issued to delete the follow ing items from from the Supply Requirement and Bid Schedule; Item No. 11(a) and 11(c).
All other terms and conditions shall remain unchanged. In addition, the solicitation period has been extended to close of business (3:30 pm EST) on 29-September-2016. All other terms and conditions shall remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 17
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 28-Sep-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912WJ-16-Q-0180
X 9B. DATED (SEE ITEM 11)
20-Sep-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
28-Sep-2016
CODE
U S ARMY ENGR DISTRICT, NEW ENGLAND
696 VIRGINIA RD
CONCORD MA 01742-2751
W912WJ 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912WJ-16-Q-0180
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 27-Sep-2016 12:00 PM to 29-Sep-2016 03:30 PM.
The following have been modified:
BID SCHEDULE(S)
**AMENDED**
BID SCHEDULE
AUTOMATED INSTRUMENTATION EQUIPMENT
Item No.
Description Quantity Unit of
Measure
Unit Cost
Total Item Cost
1 Data Loggers - CR-1000 10.00 Each
2a. Multiplexers - Littleville
Dam
1.00 Each
2b. Multiplexers - Otter Brook Dam
1.00 Each
2c. Multiplexers - Surry
Mountain Dam
3.00 Each
2d. Multiplexers - Tully Lake Dam
1.00 Each
3a. Vibrating Wire Nodes -
Black Rock Dam
7.00 Each
3b. Vibrating Wire Nodes - Conanct Brook Dam
5.00 Each
3c. Vibrating Wire Nodes -
Hancock Dam
2.00 Each
3d. Vibrating Wire Nodes - Littleville Dam
14.00 Each
3e. Vibrating Wire Nodes -
Northfield Brook Dam
3.00 Each
3f. Vibrating Wire Nodes - Otter Brook Dam
10.00 Each
3g. Vibrating Wire Nodes - Surry Mt. Dam
8.00 Each
3h. Vibrating Wire Nodes -
Tully Lake Dam
4.00 Each
3i. Vibrating Wire Nodes - West Thompson Dam
4.00 Each
3j. Vibrating Wire Nodes -
SPARES
15.00 Each
4 Base Radios 16.00 Each
5 Network Links - Eight
Dams
12.00 Each
6 Barometers - Eight Dams 12.00 Each
7a. Vibrating Wire Piezometers - Black Rock Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7b. Vibrating Wire Piezometers - Conant Brook Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7c. Vibrating Wire Piezometers - Hancock Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7d. Vibrating Wire Piezometers - Littleville Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7e. Vibrating Wire Piezometers -Northfield Brook Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7f. Vibrating Wire Piezometers - Otter Brook Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7g. Vibrating Wire Piezometers - Surry Mt.
Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7h. Vibrating Wire Piezometers - Tully Lake Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7i. Vibrating Wire Piezometers - West Thompson Dam
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
7j. Vibrating Wire Piezometers - SPARES
See Table in Section II for
Sensor & Cable Quantities
Lump Sum
8a. NEMA Aluminum
Enlclosure, 16 x 12 x 12 Pole Mount
5.00 Each
8b. NEMA Aluminum Enlclosure, 18 x 14 x 14 Pole Mount
10.00 Each
8c. NEMA Aluminum Enlclosure, 26 x 18 x 14 Pole Mount
7.00 Each
8d. NEMA Aluminum Enlclosure, 26 x 18 x 14 Pad Mount
10.00 Each
8e. Aluminum Back Panel, 8 x 13
10.00 Each
8f. Aluminum Anchor Bolt Template
9a. 10 Watt Solar Panel, Epoxy over Aluminum - Vandal Resistant
20.00 Each
9b. 20 Watt Solar Panel, Epoxy over Aluminum - Vandal Resistant
5.00 Each
10. NEMA Enclosure
Compression Coupling
11. Software Support - Field
Assistance
80.00 Hour
12. Contract Option 1 - In Section II., See
Contract Option
1. Table for Item(s) &
13. Contract Option 2 - In Section II., See
2. Table for Item(s) &
14. Contract Option 3 -
In Section II., See
3. Table for Item(s) &
15a. Contract Option 4 -
4. Table for Item(s) &
Quantities
15b. Contract Option 5 -
5. Table for Item(s) &
GRAND
TOTAL
SUPPLY REQUIREMENT
**AMENDED**
AUTOMATED INSTRUMENTATION EQUIPMENT
U.S. ARMY CORPS OF ENGINEERS
NEW ENGLAND DISTICT HQ
CONCORD, MA
SUPPLY REQUIREMENT
September 2016
SECTION I. GENERAL
Scope – Contractor shall provide all labor, materials, equipment, and transportation necessary to supply, deliver, and unload field equipment and related support services for the New England District (NAE)
Dam Safety Automated Monitoring Program. Equipment consists of data loggers, wireless radios, vibrating wire nodes, multiplexers, network links, vibrating wire sensors with specified cable lengths, solar panels, NEMA enclosures. Services consist of related field work, database programming, web portal configuration, and licensing. Items specified herein are to be provided in accordance with the following specifications and bid schedule.
Location – The New England District Headquarters is located at 696 Virginia Road in Concord, MA 01742.
All supplies shall be delivered (FOB) to the New England District Headquarters Office. However, items shall be collocated/wrapped/packaged together or in boxes labeled per the location(s) specified in the Bid Schedule.
Project Coordination – Contact the Technical Point of Contact, Mr. Christopher J. Scabia (978‐318‐8628 or Christopher.J.Scabia@usace.army.mil) to coordinate the specific delivery schedule (Date and Time).
Schedule – All materials identified in this scope shall be delivered and unloaded no later than 60 Days after contract award, or within 60 days of option award (as appropriate), except incidental database services, & field support, which can be utilized during the period of performance. The Period of Performance shall be 12 months from the date of contract award. The office will be open to the contractor Monday through Friday 7:00 AM to 4:00 PM. All deliveries shall be coordinated with the Technical Point of Contact in advance.
Payment‐ The contractor will furnish the Technical Point of Contact with one invoice, stating the materials delivered, the date of delivery, the date of acceptance and the amount to be paid. Payment shall be made for actual materials delivered at the applicable contract unit price.
All invoices may be mailed to:
U.S. Army Corps of Engineers‐New England District ATTN: Mr. Christopher J. Scabia, Engineering & Planning 696 Virginia Road Concord, MA 01742
Or Emailed to Christopher.J.Scabia@usace.army.mil
SECTION II. SPECIFICATIONS
1. DATA LOGGERS – Data loggers shall be user programmable, have two (2) com ports, be able to communicate PACKBUS protocol to communicate with existing equipment, and have minimum
16 bit resolution, and be capable of 4 differential measurements. Data loggers shall be
Campbell Scientific Model CR1000 (or equivalent).
2. Multiplexers – Multiplexers shall be capable of sixteen (16) 4‐wire, or thirty‐two (32) 2‐wire measurements, have onboard gas surge tubes, and have a compact for factor. Multiplexers shall be Canary Systems Minimux (or equivalent).
3. Vibrating Wire Nodes – Vibrating Wire Nodes shall be capable of communicating PACKBUS protocol to communicate with Data Loggers and other nodes. Nodes shall be able to measure two (2) vibrating wire sensors, and be programmable as either a relay or measuring unit.
Vibrating Wire Nodes shall be Campbell Scientific Model AVW206 (or equivalent).
4. Base Radios – Base Radios shall be capable of communicating PACKBUS protocol to communicate with Data Loggers and other nodes. Radios shall be programmable as either a master or base unit. Base Radios shall be Campbell Scientific Model RF 40(a) (or equivalent).
5. Network Links – Network Links shall be made by data logger manufacturer to be compatible with data loggers specified herein to utilize all data logger network telemetry protocols.
Network Links shall be Campbell Scientific Model NL201 (or equivalent).
6. Barometers – Barometers shall be capable of atmospheric referenced measurements for sensor drift correction. Barometers shall be Vaisala Products, PTB110 (or equivalent).
7. i. Vibrating Wire Sensors 0.69‐Inch Diameter with quantities as specified in the Sensor Table
(below). Sensors shall be barometrically sealed, stainless steel bodied, with 0.1% FS resolution.
Sensors shall be Geokon 4500B (0.69 inch diameter) (or equivalent).
ii. Vibrating Wire Sensors 0.44‐Inch Diameter with quantities as specified in the Sensor Table (below). Sensors shall be barometrically sealed, stainless steel bodied, with 0.1% FS resolution.
Sensors shall be Geokon 4500C (0.44 inch diameter) (or equivalent).
iii. Vibrating Wire Weir Monitoring System with quantities as specified in the Sensor Table (below). Sensors shall be barometrically sealed, stainless steel bodied, with 0.1% FS resolution.
Sensors shall be complete with transducer and stilling well. Model shall be Geokon 4675LV‐1‐ 600 mm [165 x 25 mm transducer] (or equivalent).
8. NEMA Enclosures – Enclosures shall be NEMA 12X, 0.125” thick aluminum on top and sides, and
0.25” thick on bottom for strength. Boxes shall be manufactured to the dimensions and specifications shown on the Enclosure Drawings. Boxes shall APX Models (www.apx‐ enclosures.com) as noted below (or equivalent). Drawings are in Appendix 1.
A. NEMA Enclosure 16 x 12 x 12 Pole Mount, APX Drawing # 1‐800‐003390, APX P/N
TCCE161212A1253R3‐4.50 HOLE‐US ARMY.
B. NEMA Enclosure 18x 14 x 14 Pole Mount, APX Drawing # 1‐800‐003386, APX P/N
TCCE181414A1253R3‐4.50 HOLE‐US ARMY.
C. NEMA Enclosure 24 x 18 x 14 Pole Mount, APX Drawing # 1‐800‐004230.
D. NEMA Enclosure 26x 18 x 14 PAD Mount, APX Drawing # 1‐800‐003389, APX P/N
TCCE261814A1253R1‐US ARMY.
E. Aluminum Back Panel, 13 x 10 w‐mounting holes to match studs, typical all boxes. APX Drawing # 6-681-000347, APX P/N BACKPANEL 13X10 US ARMY.
F. Aluminum Anchor Bolt Template, matches bolt pattern of PAD Mount Box, Item 8.D, APX Drawing # 1-688-000307, APX P/N BASE PLT A125-14X18-NAT-USARMY
9. SOLAR PANELS ‐ Solar Panels shall be vandal resistant epoxy over aluminum construction, 12
Volt, 10Watt or 20Watt as called for and made with 17.5 ft. lead cable and blocking diode.
Solar panels shall contain labels on the underside with model number, specifications, and polarity designation. Solar panels shall include pole mount brackets for 1 inch pipe.
A. 10 Watt Panel B. 20 Watt Panel
10. NEMA Enclosure Compression Coupling – Fitting to adapt NEMA enclosures shall be 4‐inch
Rigid grade electrical male terminal adapters, Cooper/Crouse‐Hinds CPR‐10. A heavy duty spanner nut shall be provided for securing the adapter to the NEMA enclosure.
11. Related Services
Field Assistance ‐ The Contractor shall provide up to 80 hours of onsite field labor for one person in CT, MA, NH and VT labor over the course of two separate one week period(s) during the period of performance. Contractor will assist Corps personnel with software configuration and setup of Campbell Scientific equipment in Multilogger in the field. Per diem is to be included in hourly unit cost for this line item. Support hours shall be provided on as needed basis for the contract period.
12. Option 1. ‐ If exercised, shall consist of the specified items as specified on the Option 1 Bid
Schedule (Items 1., 5., 7i. & 7ii). Quantities as stated on the Option 1 Bid Schedule.
13. Option 2. ‐ If exercised, shall consist of the specified items as specified on the Option 2 Bid
Schedule (Items 7i. & 7ii). Quantities as stated on the Option 2 Bid Schedule.
14. Option 3. ‐ If exercised, shall consist of the specified items as specified on the Option 3 Bid
Schedule (Items 8a.‐f., 9a.&b., & 10.). Quantities as stated on the Option 3 Bid Schedule.
15.
A. Option 4. ‐ If exercised, shall consist of the following; Pressure Transducers, self‐ contained measuring and logging of temperature and level, less than 0.75 inch diameter, titanium shell, sealed, 0.05% FS accuracy (before barometric error), capable of storing 125,000 readings, with a 10 year battery life. Transducers shall include sealed cable, terminated in “stripped and tinned” fashion. Units shall be capable of communicating with data collection equipment using SDI‐12, Mod‐bus, or 4‐20 ma output. Units shall be Level Troll 400 by In‐Situ (or equivalent). Quantities are identified on the Option 4 Bid Schedule.
B. Option 5. ‐ If exercised, same as 15.A above except cables are terminated with, or “twist lock” for surface retrieval device. Quantities are identified on the Option 5 Bid Schedule.
NOTE: 1.) The listing of the specific manufacturer names and model numbers is to establish a standard of quality, size, material, compatible architecture, and features. The contractor can provide materials of a different manufacturer subject to the alternate materials being equal (performance, architectural compatibility).2.) THE GOVERNMENT MAY ELECT TO EXERCISE
OPTONS 1 THROUGH OPTION 5; INDIVIDUALLY OR AS A WHOLE.
SECTION II. TABLES FOR SENSORS & CONTRACT OPTIONS
SECTION II Cont'd - Item 7a. VIBRATING WIRE PIEZOMETERS - Black Rock Dam
Piez. No. Sensor Model Sensor PSI Range
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ1 Spec Item 7i 50.00 Sealed 110.25 5 115 PZ2A Spec Item 7i 50.00 Sealed 163.05 5 168
PZ2B
(Replacement) May -08
Spec Item 7i 50.00 Sealed 137.39 30 167
PZ3 Spec Item 7i 50.00 Sealed 104.55 5 110 PZ4 Spec Item 7i 50.00 Sealed 58.02 5 63
PZ5A Spec Item 7i 50.00 Sealed 139.45 5 144 PZ5B Spec Item 7i 50.00 Sealed 118.88 5 124 PZ6A Spec Item 7i 50.00 Sealed 81.20 5 86 PZ6B Spec Item 7i 50.00 Sealed 61.56 5 67 PZ7A Spec Item 7i 50.00 Sealed 95.65 5 101 PZ7B Spec Item 7i 50.00 Sealed 54.17 5 59
SECTION II Cont'd - Item 7b. VIBRATING WIRE PIEZOMETERS - Conant Brook Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ1A Spec Item 7i 50.00 Sealed 90.73 5 96 PZ1B Spec Item 7i 50.00 Sealed 57.82 5 63 PZ2A Spec Item 7i 50.00 Sealed 88.78 5 94 PZ2B Spec Item 7i 50.00 Sealed 69.91 5 75 PZ3 Spec Item 7i 50.00 Sealed 54.19 5 59
SECTION II Cont'd - Item 7c. VIBRATING WIRE PIEZOMETERS - Hancock Dam
Range
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ1A Spec Item 7i 50.00 Sealed 53.63 5 59 PZ1B Spec Item 7i 50.00 Sealed 26.01 5 31 PZ2A Spec Item 7i 50.00 Sealed 77.03 5 82 PZ2B Spec Item 7i 50.00 Sealed 49.98 5 55 PZ3A Spec Item 7i 50.00 Sealed 38.92 5 44 PZ3B Spec Item 7i 50.00 Sealed 10.14 5 15
SECTION II Cont'd - Item 7d. VIBRATING WIRE PIEZOMETERS - Littleville Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ5A Spec Item 7i 50.00 Sealed 145.27 3 148 PZ5B Spec Item 7i 50.00 Sealed 101.11 3 104 PZ6A Spec Item 7i 50.00 Sealed 180.70 5 186 PZ6B Spec Item 7i 50.00 Sealed 156.43 5 161 PZ7A Spec Item 7i 50.00 Sealed 143.91 5 149 PZ7B Spec Item 7i 50.00 Sealed 111.47 5 116 PZ10 Spec Item 7i 50.00 Sealed 43.48 5 48 PZ11 Spec Item 7i 50.00 Sealed 27.78 5 33 PZ12 Spec Item 7i 50.00 Sealed 20.36 5 25
PZ13A Spec Item 7i 50.00 Sealed 147.60 3 151 PZ13B Spec Item 7i 50.00 Sealed 147.60 3 151 PZ14A Spec Item 7i 50.00 Sealed 147.60 5 153 PZ14B Spec Item 7i 50.00 Sealed 147.60 5 153 PZ15 Spec Item 7i 50.00 Sealed 147.60 5 153
PZ16A Spec Item 7i 50.00 Sealed 147.60 3 151 PZ16B Spec Item 7i 50.00 Sealed 147.60 3 151 PZ17A Spec Item 7i 50.00 Sealed 147.60 5 153 PZ17B Spec Item 7i 50.00 Sealed 147.60 5 153 PZ18 Spec Item 7i 50.00 Sealed 147.60 5 153 PZ19 Spec Item 7i 50.00 Sealed 147.60 25 173 PZ20 Spec Item 7i 50.00 Sealed 147.60 15 163 PZ21 Spec Item 7i 50.00 Sealed 147.60 5 153 PZ22 Spec Item 7i 50.00 Sealed 147.60 25 173
PZWEIRSTAGE Spec Item 7iii 50.00 Sealed 147.60 5 153
SECTION II Cont'd - Item 7e. VIBRATING WIRE PIEZOMETERS - Northfield Brook Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ1A Spec Item 7i 50.00 Sealed 128.52 5 134 PZ1B Spec Item 7i 50.00 Sealed 101.09 5 106 PZ2A Spec Item 7i 50.00 Sealed 95.82 5 101 PZ2B Spec Item 7i 50.00 Sealed 83.98 5 89 PZ3 Spec Item 7i 50.00 Sealed 24.90 5 30
SECTION II Cont'd - Item 7f. VIBRATING WIRE PIEZOMETERS - Otter Brook Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ12A Spec Item 7i 50.00 Sealed 113.18 5 118 PZ12B Spec Item 7i 50.00 Sealed 104.74 5 110 PZ13A Spec Item 7i 50.00 Sealed 140.69 5 146 PZ13B Spec Item 7i 50.00 Sealed 120.68 5 126 PZ14A Spec Item 7i 50.00 Sealed 62.98 5 68 PZ14B Spec Item 7i 50.00 Sealed 50.66 5 56 PZ15A Spec Item 7i 50.00 Sealed 31.86 5 37 PZ15B Spec Item 7i 50.00 Sealed 14.09 5 19 PZ16A Spec Item 7i 50.00 Sealed 32.36 5 37 PZ16B Spec Item 7i 50.00 Sealed 14.23 5 19 PZ17 Spec Item 7i 50.00 Sealed 15.23 5 20 PZ18 Spec Item 7i 50.00 Sealed 16.23 5 21
PZ19A Spec Item 7i 50.00 Sealed 17.23 5 22 PZ19B Spec Item 7i 50.00 Sealed 18.23 5 23 PZ20A Spec Item 7i 50.00 Sealed 19.23 5 24 PZ20B Spec Item 7i 50.00 Sealed 20.23 5 25 PZ21A Spec Item 7i 50.00 Sealed 21.23 3 24 PZ21B Spec Item 7i 50.00 Sealed 22.23 3 25 PZ22A Spec Item 7i 50.00 Sealed 23.23 3 26 PZ22B Spec Item 7i 50.00 Sealed 24.23 3 27 PZ23A Spec Item 7i 50.00 Sealed 25.23 3 28 PZ23B Spec Item 7i 50.00 Sealed 26.23 3 29 PZ24A Spec Item 7i 50.00 Sealed 27.23 3 30 PZ24B Spec Item 7i 50.00 Sealed 28.23 3 31
SECTION II Cont'd - Item 7g. VIBRATING WIRE PIEZOMETERS - Surry Mountain Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ1 Spec Item 7i 50.00 Sealed 72.38 5 77 PZ4 Spec Item 7i 50.00 Sealed 20.06 3 23 PZ5 Spec Item 7i 50.00 Sealed 59.05 3 62
PZ9A Spec Item 7i 50.00 Sealed 29.02 5 34 PZ9B Spec Item 7i 50.00 Sealed 13.52 5 19 PZ10 Spec Item 7i 50.00 Sealed 12.85 5 18
PZ11A Spec Item 7i 50.00 Sealed 27.98 5 33 PZ11B Spec Item 7i 50.00 Sealed 13.33 5 18 PZ12A Spec Item 7i 50.00 Sealed 59.13 5 64 PZ12B Spec Item 7i 50.00 Sealed 38.33 5 43 PZ13A Spec Item 7i 50.00 Sealed 121.73 5 127 PZ13B Spec Item 7i 50.00 Sealed 92.73 5 98 PZ14A Spec Item 7i 50.00 Sealed 119.76 5 125 PZ14B Spec Item 7i 50.00 Sealed 93.06 5 98 PZ15A Spec Item 7i 50.00 Sealed 115.46 5 120 PZ15B Spec Item 7i 50.00 Sealed 93.45 5 98 PZ16A Spec Item 7i 50.00 Sealed 50.35 3 53 PZ16B Spec Item 7i 50.00 Sealed 10.89 4 15 PZ17A Spec Item 7i 50.00 Sealed 48.00 5 53 PZ17B Spec Item 7i 50.00 Sealed 26.20 6 32 PZOW1 Spec Item 7i 50.00 Sealed 11.76 7 19
SECTION II Cont'd - Item 7h. VIBRATING WIRE PIEZOMETERS - Tully Lake Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ11A Spec Item 7i 50.00 Sealed 54.54 3 58 PZ11B Spec Item 7i 50.00 Sealed 42.78 3 46 PZ12A Spec Item 7i 50.00 Sealed 49.09 3 52 PZ12B Spec Item 7i 50.00 Sealed 39.05 3 42 PZ13A Spec Item 7i 50.00 Sealed 76.52 3 80 PZ13B Spec Item 7i 50.00 Sealed 59.70 3 63 PZ14A Spec Item 7i 50.00 Sealed 61.50 3 65 PZ14B Spec Item 7i 50.00 Sealed 44.70 3 48 PZ15 Spec Item 7i 50.00 Sealed 40.98 3 44
SECTION II Cont'd - Item 7i. VIBRATING WIRE PIEZOMETERS - West Thompson Dam
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
PZ1 Spec Item 7i 50.00 Sealed 63.80 3 67 PZ2 Spec Item 7i 50.00 Sealed 81.63 10 92 PZ3 Spec Item 7i 50.00 Sealed 34.23 10 44 PZ4 Spec Item 7i 50.00 Sealed 21.67 5 27
PZ5A Spec Item 7i 50.00 Sealed 97.05 3 100 PZ5B Spec Item 7i 50.00 Sealed 77.04 3 80 PZ6A Spec Item 7i 50.00 Sealed 96.60 3 100 PZ6B Spec Item 7i 50.00 Sealed 74.45 3 77 PZ7A Spec Item 7i 50.00 Sealed 64.13 5 69 PZ7B Spec Item 7i 50.00 Sealed 44.93 5 50 PZ8A Spec Item 7i 50.00 Sealed 45.93 5 51 PZ8B Spec Item 7i 50.00 Sealed 46.93 5 52 PZ9 Spec Item 7i 50.00 Sealed 47.93 5 53 PZ10 Spec Item 7i 50.00 Sealed 48.93 49
SECTION II Cont'd - Item 7j. VIBRATING WIRE
PIEZOMETER - SPARES
Quantity Sensor Model Sensor PSI
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
5 Spec Item 7i 50.00 Sealed 75.00 3 390 5 Spec Item 7i 50.00 Sealed 100.00 10 550 5 Spec Item 7i 50.00 Sealed 125.00 10 675 5 Spec Item 7i 50.00 Sealed 175.00 5 900 5 Spec Item 7i 100.00 Sealed 200.00 3 1015 5 Spec Item 7i 100.00 Sealed 250.00 3 1265 2 Spec Item 7i 100.00 Sealed 340.00 10 700
5 Spec Item 7ii 50.00 Sealed 75.00 3 390 5 Spec Item 7ii 50.00 Sealed 100.00 10 550 5 Spec Item 7ii 50.00 Sealed 125.00 10 675 5 Spec Item 7ii 50.00 Sealed 175.00 5 900 5 Spec Item 7ii 100.00 Sealed 200.00 3 1015 5 Spec Item 7ii 100.00 Sealed 250.00 3 1265 2 Spec Item 7ii 100.00 Sealed 340.00 10 700
SECTION II Cont'd - CONTRACT OPTION 1.
Quantity Bid Item Sensor PSI
Range Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
2 Spec Item 1. DATA
LOGGERS
N/A N/A N/A N/A N/A
25 Spec Item 5. NETWORK
LINKS
N/A N/A N/A N/A N/A
5 Spec Item 7i 50.00 Sealed 75.00 3 390 5 Spec Item 7i 50.00 Sealed 100.00 10 550 5 Spec Item 7i 50.00 Sealed 125.00 10 675 5 Spec Item 7i 50.00 Sealed 175.00 5 900 5 Spec Item 7ii 50.00 Sealed 125.00 10 675 5 Spec Item 7ii 50.00 Sealed 175.00 5 900 5 Spec Item 7ii 100.00 Sealed 200.00 3 1015
SECTION II Cont'd - CONTRACT OPTION 2.
Quantity Sensor Model Sensor PSI
Range Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
10 Spec Item 7i 50.00 Sealed 75.00 3 780 10 Spec Item 7i 50.00 Sealed 100.00 10 1100 10 Spec Item 7i 50.00 Sealed 125.00 10 1350 10 Spec Item 7i 50.00 Sealed 175.00 5 1800 10 Spec Item 7i 100.00 Sealed 200.00 3 2030 5 Spec Item 7i 100.00 Sealed 250.00 3 1265 5 Spec Item 7i 100.00 Sealed 300.00 3 1515 10 Spec Item 7ii 50.00 Sealed 75.00 3 780 10 Spec Item 7ii 50.00 Sealed 100.00 10 1100 10 Spec Item 7ii 50.00 Sealed 125.00 10 1350 10 Spec Item 7ii 50.00 Sealed 175.00 5 1800 10 Spec Item 7ii 100.00 Sealed 200.00 3 2030 5 Spec Item 7ii 100.00 Sealed 250.00 3 1265 5 Spec Item 7ii 100.00 Sealed 300.00 3 1515
SECTION II Cont'd - CONTRACT OPTION 3.
Quantity Bid Item Sensor PSI
Range Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
5 Spec Item 8a. NEMA Aluminum Enlclosure, 16 x 12 x 12 Pole Mount
N/A N/A N/A N/A N/A
5 Spec Item 8b. NEMA N/A N/A N/A N/A N/A
Aluminum Enlclosure, 18 x 14 x 14 Pole Mount
5 Spec Item 8c. NEMA Aluminum Enlclosure, 26 x 18 x 14 Pole Mount
N/A N/A N/A N/A N/A
5 Spec Item 8d. NEMA Aluminum Enlclosure, 26 x 18 x 14 Pad Mount
N/A N/A N/A N/A N/A
5 Spec Item 8e. Aluminum Back Panel, 8 x 13
N/A N/A N/A N/A N/A
5 Spec Item 8f. Aluminum Anchor Bolt Template
N/A N/A N/A N/A N/A
20.00 Spec Item 9a.10 Watt Solar
Panel, Epoxy over Aluminum
- Vandal Resistant
N/A N/A N/A N/A N/A
5.00 Spec Item 9b.20 Watt Solar
Panel, Epoxy over Aluminum
- Vandal Resistant
N/A N/A N/A N/A N/A
5.00 Spec Item 10.NEMA
Enclosure Compression Coupling
N/A N/A N/A N/A N/A
SECTION II Cont'd - CONTRACT OPTION 4.
Quantity Bid Item Sensor
PSIa Range
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
5 Spec Item 15a. w-Stripped & Tinned Wires
30.00 Sealed 50.00 5 275
1 Spec Item 15a. w-Stripped & Tinned Wires
30.00 Sealed 100.00 5 105
SECTION II Cont'd - CONTRACT OPTION 5.
Quantity Bid Item Sensor
PSIa Range
Vented / Sealed
Embankme nt Cable
Length (ft.)
Additiona l Horiz.
Cable (ft.)
Total Cable (ft.)
5 Spec Item 15b. w-Twist lock connector (both ends)
30.00 Sealed 50.00 5 275
1 Spec Item 15b. w-Twist lock connector (both ends)
30.00 Sealed 100.00 5 105
(End of Summary of Changes)